31

Ocorrência e remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. em Reatores Anaeróbios de Fluxo Ascendente e Manta de Lodo (UASB) operando com esgoto sanitário e águas negras simuladas / Occurrence and removal of Giardia spp. and Cryptosporidium spp. in Upflow Anaerobic Sludge Blanket Reactors (UASB) operating with sewage and simulated black water

Fernanda Queiroz Valdez 09 September 2016 (has links)
As doenças de veiculação hídrica são uma preocupação no mundo todo, e tem aumentado cada vez mais o interesse nos estudos relacionados aos protozoários Cryptosporidium spp. e Giardia spp.. A presença de protozoários em águas de abastecimento está vinculada ao lançamento de esgoto nos mananciais, de modo que o tratamento de esgotos sanitários é de extrema importância para reduzir o risco de surtos de protozooses. Este trabalho avaliou a ocorrência e a possibilidade de remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. em dois reatores UASB, um piloto e um em escala plena, operados com esgoto sanitário e um TDH de aproximadamente 8h, e um reator UASB piloto, operado com água negra simulada e um TDH aproximado de três dias. Nos dois reatores operados com esgoto sanitário as remoções foram semelhantes. A média de DQO total afluente, no reator piloto e no de escala plena, foi de 271 e 410 mg/L, respectivamente, e as remoções médias de DQO foram de 50,62 e 45,80%, respectivamente. Com relação aos exames parasitológicos, quase não houve remoção em ambos os reatores e, na maior parte dos casos, o número de (oo)cistos detectados no efluente foi maior do que no afluente. Já no reator piloto operado com águas negras, foram observadas remoções mais elevadas. A DQO total afluente desse reator variou de 837 a 3269 mg/L e a remoção média observada foi de 71,22%. Neste reator também foram observadas maiores remoções de (oo)cistos, sendo que a remoção de cistos Giardia spp. variou de 67,73 a 93,69% e, em um dos ensaios, foi observada uma remoção de 70% de oocistos de Cryptosporidium spp. Acredita-se que o melhor desempenho desse reator se deve ao seu elevado tempo de detenção hidráulico. Foi avaliada, ainda, a ocorrência de (oo)cistos no lodo dos três reatores, resultando em valores bastante elevados, da ordem de 105 cistos/g de massa seca, em todos eles. De qualquer modo, em todos os reatores avaliados, mesmo o que apresentou as maiores eficiências, o efluente ainda apresentava altas concentrações de poluentes, necessitando de um pós-tratamento para a remoção dos remanescentes de matéria orgânica, sólidos e patógenos. / The waterborne diseases are a concern worldwide, and has grown more and more interest in studies related to the protozoa Cryptosporidium spp. and Giardia spp. The presence of protozoa in drinking water is related to the release of sewage in water sources. So that, the sewage treatment is extremely important to reduce the risk of outbreaks protozoa. This study evaluated the occurrence and the possibility of removal of Giardia spp. and Cryptosporidium spp. in two UASB reactors, a pilot and a full-scale, operated with sewage and a HRT of 8 hours, approximately, and a pilot UASB reactor, operated with simulated black water and an approximate HRT of three days. Removals were similar in both reactors operated with sewage. The average influent total COD, in pilot and full scale reactors, was 271 and 410 mg/L, respectively, and the average COD removal were 50.62 and 45.80%, respectively. With the parasitological test, there was almost no removal in both reactors and, in most cases, the number of (oo)cysts detected in the effluent was higher than in the influent. In the pilot reactor operated with black water, higher removals were observed. The total COD influent of this reactor ranged from 837 to 3269 mg/L and the average removal observed was 71.22%. In this reactor (oo)cysts removals were also higher, and the removal of Giardia cysts ranged from 67.73 to 93.69%, and in one of the trials, a 70% removal of Cryptosporidium spp was observed. It is believed that the best performance of this reactor is due to its high hydraulic retention time. The occurrence of (oo)cysts in the sludge of the three reactors was also evaluated, resulting in very high values of the order of 105 cysts/g of dry weight, in all of them. Anyway, in all this reactor, even the one with the highest efficiency, the effluent still had high concentrations of pollutants, necessitating a post treatment for the removal of remaining organic matter, solids and pathogens.
32

Desempenho de reator anaeróbio híbrido (leito fixo e manta de lodo) tratando esgoto sanitário em escala piloto / Performance of anaerobic hybrid reactor (fixed bed and sludge blanket) for sewage treatment in pilot scale

Araujo, Thiago Lopes da Silva 09 June 2014 (has links)
O presente trabalho estudou o aumento de capacidade de tratamento de um reator UASB (Upflow Anaerobic Sludge Blanket) por meio da adição de material suporte para adesão celular (Biobob®), avaliando-se as eficiências de remoção de matéria orgânica (expressa como DQO demanda química de oxigênio) e sólidos em suspensão (expressos como SST sólidos em suspensão totais). O reator híbrido, no qual a biomassa está presente em suspensão e imobilizada no material suporte, foi submetido a baixos tempos de detenção hidráulica (TDH) e altas velocidades ascensionais (vs). A operação do reator anaeróbio, de volume útil igual a 12,5 m³, foi conduzida em duas etapas. Na primeira o sistema foi operado como um reator de manta de lodo e escoamento ascendente (UASB), com TDH de 8,8 h e velocidade ascensional de 0,63 m.h-1. Na segunda etapa, introduziu-se 5,0 m³ de material suporte Biobob® no leito reacional do reator, transformando-o em reator anaeróbio híbrido (HAnR). Nessa condição, variou-se a vazão de alimentação, tendo o TDH variado entre 7,4 h (vs de 0,66 m.h-1) a 3,9 h (vs de 1,25 m.h-1). Para ambas as etapas o sistema foi alimentado com esgoto sanitário à temperatura ambiente, após tratamento preliminar (gradeamento e caixa de areia). Para condições de operação similares, o reator anaeróbio híbrido (HAnR) apresentou melhor desempenho na remoção de DQO e SST que o reator UASB, acrescendo em até 18% e 30% a eficiência de remoção, respectivamente. Para a velocidade ascensional de 1,25±0,02 m.h-1 e TDH de 3,9±0,1 h, o HAnR apresentou concentrações médias no efluente tratado de 205±46 mg DQOt.L-1 e 73±30 mg SST.L-1 e eficiências de remoção de 55±9% DQOt e 63±14% SST. / The increase of the treatability capacity of a UASB (Upflow Anaerobic Sludge Blanket) reactor by introducing an innovative packing material (Biobob®) in its reaction zone was evaluated. The hybrid anaerobic reactor (HAnR) containing suspended and immobilized biomass was evaluated regarding its efficiency of removing organic matter (expressed as COD chemical oxygen demand) and suspended solids (expressed as TSS total suspended solids) under lower hydraulic detention time (HDT) and higher upflow velocities (v s). The anaerobic reactor operation, with 12.5 m³ of working volume, was conducted in two phases. In the first phase, the system was operated as a conventional UASB reactor with HRT of 8.8 h and vs of 0.63 m.h -1 . In the second phase, 5.0 m³ of packing material Biobob® was introduced inside the reaction bed, changing the reactor configuration from suspended growth to hybrid growth. In this condition, the hybrid anaerobic reactor (HAnR) was subjected to decreasing flowrates with HDT ranging from 7.4 h (vs of 0.66 m.h-1) to 3.9 h (vs of 1.25 m.h-1). For both phases, the feed was domestic wastewater (after screens and grit chambers) at ambient temperature. Under similar operation conditions, the HAnR performed better than the UASB reactor increasing at 18% and 30% the COD and TSS removal efficiencies, respectively. For vs of 1.25±0.02 m.h-1 and HDT of 3.9±1.0 h, the HAnR produced a very high quality effluent, with average COD and TSS concentration of 205±46 mg DQOt.L-1 and 73±30 mg SST.L-1 and removal efficiencies of 55±9% and 63±14% for CODt and SST, respectively.
33

Avaliação do tratamento de esgoto sanitário combinado com resíduos sólidos de restaurantes em biodigestor chinês e reator UASB

Stockmanns, Ádrian Juchem 30 August 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-11-17T13:39:14Z No. of bitstreams: 1 Ádrian Juchem Stockmanns_.pdf: 9128543 bytes, checksum: 4439d237e66a4448ce2e08a6e7298d7d (MD5) / Made available in DSpace on 2017-11-17T13:39:14Z (GMT). No. of bitstreams: 1 Ádrian Juchem Stockmanns_.pdf: 9128543 bytes, checksum: 4439d237e66a4448ce2e08a6e7298d7d (MD5) Previous issue date: 2017-08-30 / Nenhuma / Este trabalho teve os objetivos de estudar o tratamento de esgoto sanitário através de um biodigestor do tipo chinês (Etapa 1) e de um reator UASB (Etapa 2), além do tratamento de esgoto sanitário em conjunto com resíduos sólidos de restaurantes através de um reator UASB (Etapa 3). O experimento foi realizado na Estação de Tratamento de Esgotos da UNISINOS (Universidade do Vale do Rio dos Sinos), aonde inicialmente foi dada a partida nos sistemas (biodigestor e reator) através da utilização de lodo do UASB existente na ETE da UNISINOS como inóculo. Relacionando as etapas 1 e 2, as análises de cor aparente, cor verdadeira e turbidez apresentaram valores superiores nas análises de Saída durante a Etapa 1. Na Etapa 2 os resultados de cor aparente e turbidez apresentaram uma redução de 41% e 77% respectivamente. As análises de DBO apresentaram uma redução de 32% entre a Entrada e Saída do reator na Etapa 2 contra 17% na Etapa 1. Nas análises de DQO, a média considerada de remoção foi de 20% na Etapa 2 contra 52% na Etapa 1, porém as últimas análises da Etapa 2 chegaram a uma redução de 80% nas análises de Saída. Relacionando as etapas 2 e 3 as análises de cor (aparente e verdadeira), DBO e DQO apresentaram valores superiores na Saída devido a adição de RSR. Comparando com a etapa aonde não foi adicionado RSR (Etapa 2) os parâmetros analisados (com exceção do pH e turbidez) apresentaram-se superiores após a adição de RSR. Em relação a geração de biogás foi comprovado o aumento na produção de biogás após a adição de resíduos, algo que de fato ocorreu principalmente após a segunda adição de resíduo, impulsionando um aumento de aproximadamente 80% em sua geração, havendo, portanto, um indicativo da possibilidade de tratamento combinado, no mesmo reator, de esgoto sanitário e resíduos sólidos de restaurantes. Os resultados sugerem que a configuração de reator UASB (Etapa 2 e 3) possui um poder de remoção de matéria orgânica superior a configuração do biodigestor chinês (Etapa 1), o que impulsiona estudos com um período maior de operação com a introdução de RSR para um tratamento integrado (ES e RSR) em reatores UASB. / This work had the objectives of studying the sewage treatment through a Chinese-type digester (Stage 1) and a UASB reactor (Stage 2), besides the sewage treatment together with solid waste from restaurants through a USB reactor (Stage 3). The experiment was performed at Estação de Tratamento de Esgotos da UNISINOS (Universidade do Vale do Rio dos Sinos), where the systems were initially started (biodigester and reactor) through the use of UASB’s Iodine existing in ETE from UNISINOS as inoculum. Relating stages 1 and 2, the analysis of apparent color, true color and turbidity presented higher values in the reactor outlet analysis during stage 1. In stage 2, the apparent color and turbidity results presented a reduction of 41% and 77% respectively. The analysis of DBO presented a reduction of 32% between the inlet and outlet of the reactor in stage 2 against 17% in stage 1. In the DQO analysis, the considered mean of removal was 20% in stage 2 against 52% in stage 1, however the stage 2 latest reviews came to a reduction of 80% in the reactor outlet analysis. Relating stages 2 and 3, the color reviews (apparent and true), DBO and DQO presented higher values in the outlet due to the addition of RSR. Comparing to the stage in which no RSR was added (Stage 2), the parameters analyzed (except for pH and turbidity) presented higher after the addition of RSR. About the generation of biogas, the increase in biogas production after the waste addition has been proven, something that actually occurred mainly after the second waste addition, boosting an increase of approximately 80% in its generation, having, therefore, indicative of the possibility of combined treatment, in the same reactor, of sanitary sewage and solid waste from restaurants. The results suggest that the UASB reactor configuration (Stages 2 and 3) has a power of removal of organic matter higher than the Chinese-type digester configuration (Stage 1), which boosts studies with a longer period of operation with the introduction of RSR for a integrated treatment (ES and RSR) in UASB reactors.
34

TRATAMENTO CONJUGADO DE LIXIVIADO COM ESGOTOS DOMÉSTICOS EM REATOR UASB / TREATMENT CONJUGATE IN HOUSEHOLD SEWAGE leached with UASB REACTOR

Ramos, Patrícia Carvalho de Aquino 18 August 2009 (has links)
Made available in DSpace on 2015-09-25T12:23:37Z (GMT). No. of bitstreams: 1 Patricia Carvalho.pdf: 1090354 bytes, checksum: 2030967b9c0c255376ba3167b9a6b633 (MD5) Previous issue date: 2009-08-18 / In terms of the actual Brazilian scenario, 56% of the solid s treatment units produce leachate, 46.8% of this leachate is treated and 70.4% of Brazilian residences are sewered. The development of methods to jointly treat landfill leachate and domestic sewage must recognize the great potential that landfill leachate has as a pollutant and the advantages gained by this combined treatment. The combined treatment of leachate and domestic sewage already exists at full-scale but studies on the optimum levels of dilution of the leachate with sewage are yet to be resolved. The objective of this work was to study the efficiency of a UASB reactor treating landfill leachate in combination with different proportions of domestic sewage, evaluate the influence of the organic loading on the treatment process and develop a biological treatment technology for residual liquids with high pollution loads. The study was carried out between February 2008 and February 2009. The UASB reactor was constructed, installed and monitored at EXTRABES in the municipality of Campina Grande PB. The UASB was constructed in PVC tubing with a diameter of 150mm, 2.35m in height and with a total volume of 41.5L and the treatment consisted of two phases. In the first phase of operation, the UASB reactor was fed with leachate and domestic sewage in ratio of 1:9 by volume respectively, resulting in an AOL of 2.1 kg m-3 d-1. In the second phase of operation the volumetric fraction of leachate was reduced in the proportion of 0.3 to 9.7 of the volume of domestic sewage or 1.6 kg m-3 d-1. The leachate used in this study were from the Metropolitan Landfill in the city of Joao Pessoa and pre-treated for removal of the load of ammonia in piston flow for stripping of ammonia. The domestic wastewater used in this study came from the city where the study was conducted in Campina Grande.In both phases the HRT was 12 hours and the flow of 83L d-1. The influent and effluent of the experimental system were monitored for pH, VFA and TA twice. Analysis of COD, TSS and VSS were monitored weekly. All tests were recommended by APHA (1998). The results show that the combined treatment of landfill leachate diluted domestic sewage in a UASB reactor is technologically feasible alternative and produces effluent with characteristics satisfactory to post-treatment in stabilization ponds. Were obtained removal efficiencies of 44.0, 48.5, 85.4 and 79.9% in the first stage and 59.4, 53.6, 92.7 and 89.8% in the second step for the parameter of COD , STV, TSS and VSS respectively. The second stage had the highest decomposition constants for the parameters of STV, TSS and VSS. It is recommended the continuation of studies of treatment of leachate from landfill diluted sewage with COA than 1.6 kg COD m-3d-1. / No atual cenário brasileiro 56% das unidades de processamento de resíduos drenam lixiviado, apenas 46,8 % tratam esse lixiviado e 70,4% dos domicílios brasileiros são atendidos por rede coletora de esgotamento sanitário. O desenvolvimento de métodos de tratamento integrado de lixiviado e esgotos domésticos é necessário, visto grande potencial poluidor do lixiviado e as vantagens apresentadas nesse tratamento combinado. O tratamento conjugado de lixiviado com esgotos domésticos em escala real já existe, porém, estudar as faixas de diluições de lixiviado para realização do tratamento conjugado em faixas ótimas é imprescindível.Os objetivos deste trabalho foram estudar o desempenho de reator UASB no processo de tratamento de lixiviado combinado com esgotos domésticos em diferentes proporções, avaliar a influência da carga orgânica aplicada no processo de tratamento conjugado de lixiviado e esgoto doméstico em reator UASB e desenvolver tecnologia de tratamento biológico para resíduos líquidos com elevada carga poluidora. O trabalho foi realizado no período de Fevereiro de 2008 a Fevereiro de 2009. O reator UASB foi construído, instalado e monitorado nas dependências físicas da EXTRABES no município de Campina Grande PB. O reator UASB foi construído em tubo de PVC com diâmetro de 150 mm, 2,35 m de altura e volume total de 41,5 L e o tratamento consistiu de duas etapas. Na primeira etapa o reator UASB foi alimentado com lixiviado numa proporção de 1 para 9 vezes o volume de esgoto doméstico, o que resultou numa COA de 2,1 kg m-3dia-1. Na segunda fase de operação a fração volumétrica de lixiviado foi diminuída para a proporção de 0,3 para cada 9,7 vezes o volume de esgoto doméstico ou COA de 1,6 kg m-3 dia-1. O lixiviado utilizado neste trabalho foi proveniente do Aterro Sanitário Metropolitano da cidade de João Pessoa e era pré-tratado para remoção da carga de amônia em reatores de fluxo pistonado para Stripping de amônia. O esgoto doméstico utilizado neste trabalho foi proveniente da cidade onde o estudo foi realizado, Campina Grande-PB. Em ambas as etapas do tratamento o TDH foi 12 horas e a vazão de 83 L.d-1. O monitoramento do sistema experimental foi realizado no afluente e efluente do reator e as análises referentes aos parâmetros pH, AGV e AT foram realizadas duas vezes por semana. As análises referentes aos parâmetros DQO total e solúvel, STV, SST e SSV foram realizadas semanalmente. Todas as análises foram preconizados por APHA (1998). Os resultados mostram que o tratamento conjugado de lixiviado de aterro sanitário diluído em esgotos domésticos em reator UASB é uma alternativa tecnologicamente viável e produz efluente com características satisfatórias para pós-tratamento em lagoas de estabilização. Foram obtidas eficiências de remoção de 44,0; 48,5; 85,4 e 79,9% na primeira etapa e 59,4; 53,6; 92,7 e 89,8% na segunda etapa para os parâmetro de DQO, STV, SST e SSV respectivamente. A segunda etapa apresentou as maiores constantes de decomposição para os parâmetros de STV, SST e SSV. Recomenda-se a continuidade dos estudos de tratamento de lixiviado proveniente de aterro sanitário diluído em esgoto doméstico com COA superior a 1,6 Kg DQO m-3d-1.
35

Reator híbrido associando reator UASB e reator radial de leito fixo (RRLF), em escala piloto, no tratamento de esgoto sanitário / not available

Lopes, Alexandre Colzi 10 June 2005 (has links)
Os sistemas combinados anaeróbio/aeróbio para tratamento de esgotos sanitários têm sido considerados alternativas viáveis do ponto de vista técnico-econômico em relação aos sistemas tradicionais. Este trabalho apresenta os resultados obtidos com uma nova configuração de reator, composto por uma unidade central - um reator anaeróbio de manta de lodo (UASB) modificado de 286 L, associado a um reator radial aerado de leito fixo (RRLF) de 215 L, disposto de maneira a circundar a zona de separação sólido/líquido/gás do reator UASB. A principal modificação no reator UASB foi, portanto, a incorporação, junto à sua parede externa, do RRLF. A alimentação do RRLF com o efluente do UASB dá-se através de aberturas laterais na parede do UASB, o que permitiu eliminar as calhas de coleta e sistemas de alimentação do segundo reator. Esse sistema foi alimentado com esgoto sanitário obtido da rede coletora de esgotos do campus da USP de São Carlos. Esperava-se obter remoção considerável de matéria orgânica solúvel e particulada, bem como a remoção parcial de nitrogênio. Foram obtidas eficiências médias de remoção de matéria orgânica (expressa como demanda química de oxigênio - DQO) e de sólidos suspensos voláteis (SSV), de 80% e 89%, respectivamente. Em condições de operação estável, os valores de DQO e SSV no efluente atingiram 110 mg/L e 16 mg/L, respectivamente. Observou-se, também, que o sistema apresentou grande estabilidade operacional, tendo a taxa de carregamento orgânico volumétrica atingido valores da ordem de 4,0 Kg DQO.m-3d-1. Nessas condições, o sistema atingiu eficiências de remoção de DQO e SSV da ordem de 90%. O sistema misto ensaiado mostrou ser uma configuração promissora, pois promoveu a remoção eficiente de matéria orgânica e de sólidos suspensos. Considera-se, no entanto, a necessidade de se introduzirem modificações no projeto RRLF que permitam o estabelecimento dos processos de nitrificação e desnitrificação nesse reator, uma vez que foi obtida baixa eficiência de nitrificação e, conseqüentemente, a remoção de nitrogênio foi prejudicada. / Integrated anaerobic/aerobic systems have been considered feasible alternatives concerning technical and economic aspects for treating domestic wastewaters. This paper presents the results obtained from the operation of this new reactor configuration, made up of a central unit - an upflow anaerobic sludge blanket reactor (UASB), with a working volume of 286 L, associated to a radial-flow aerobic immobilized-biomass (RAIB), with a working volume of 215 L. The RAIB reactor circles the solid/liquid/gas separation zone. The main modification in the UASB reactor concerns this association with the RAIB. The UASB effluent was distributed through openings along its side walls to the RAIB, allowing the elimination of collecting channels and feeding devices from the latter reactor. The objective of this work was to promote organic matter (raw and soluble) and nitrogen removal from domestic sewage. Organic matter (as COD) and volatile suspended solids removal achieved efficiencies of 80% and 89%, respectively. Under stable operational conditions, the system effluent presented COD and volatile suspended solids values of 110 mg/L and 16 mg/L, respectively. Efficiencies of 90% for COD and volatile suspended solids removal were achieved with a organic loading rate of 4,0 Kg COD.m-3.d-1. This integrated system has shown to be a valid configuration, efficiently removing organic matter and suspended solids from the domestic wastewater. However, contrarily to expectations based on the previous studies with RAIB, nitrification was poor. Therefore, modifications to the RAIB design must be considered for the establishment of nitrogen removing processes.
36

Ocorrência e remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. em Reatores Anaeróbios de Fluxo Ascendente e Manta de Lodo (UASB) operando com esgoto sanitário e águas negras simuladas / Occurrence and removal of Giardia spp. and Cryptosporidium spp. in Upflow Anaerobic Sludge Blanket Reactors (UASB) operating with sewage and simulated black water

Valdez, Fernanda Queiroz 09 September 2016 (has links)
As doenças de veiculação hídrica são uma preocupação no mundo todo, e tem aumentado cada vez mais o interesse nos estudos relacionados aos protozoários Cryptosporidium spp. e Giardia spp.. A presença de protozoários em águas de abastecimento está vinculada ao lançamento de esgoto nos mananciais, de modo que o tratamento de esgotos sanitários é de extrema importância para reduzir o risco de surtos de protozooses. Este trabalho avaliou a ocorrência e a possibilidade de remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. em dois reatores UASB, um piloto e um em escala plena, operados com esgoto sanitário e um TDH de aproximadamente 8h, e um reator UASB piloto, operado com água negra simulada e um TDH aproximado de três dias. Nos dois reatores operados com esgoto sanitário as remoções foram semelhantes. A média de DQO total afluente, no reator piloto e no de escala plena, foi de 271 e 410 mg/L, respectivamente, e as remoções médias de DQO foram de 50,62 e 45,80%, respectivamente. Com relação aos exames parasitológicos, quase não houve remoção em ambos os reatores e, na maior parte dos casos, o número de (oo)cistos detectados no efluente foi maior do que no afluente. Já no reator piloto operado com águas negras, foram observadas remoções mais elevadas. A DQO total afluente desse reator variou de 837 a 3269 mg/L e a remoção média observada foi de 71,22%. Neste reator também foram observadas maiores remoções de (oo)cistos, sendo que a remoção de cistos Giardia spp. variou de 67,73 a 93,69% e, em um dos ensaios, foi observada uma remoção de 70% de oocistos de Cryptosporidium spp. Acredita-se que o melhor desempenho desse reator se deve ao seu elevado tempo de detenção hidráulico. Foi avaliada, ainda, a ocorrência de (oo)cistos no lodo dos três reatores, resultando em valores bastante elevados, da ordem de 105 cistos/g de massa seca, em todos eles. De qualquer modo, em todos os reatores avaliados, mesmo o que apresentou as maiores eficiências, o efluente ainda apresentava altas concentrações de poluentes, necessitando de um pós-tratamento para a remoção dos remanescentes de matéria orgânica, sólidos e patógenos. / The waterborne diseases are a concern worldwide, and has grown more and more interest in studies related to the protozoa Cryptosporidium spp. and Giardia spp. The presence of protozoa in drinking water is related to the release of sewage in water sources. So that, the sewage treatment is extremely important to reduce the risk of outbreaks protozoa. This study evaluated the occurrence and the possibility of removal of Giardia spp. and Cryptosporidium spp. in two UASB reactors, a pilot and a full-scale, operated with sewage and a HRT of 8 hours, approximately, and a pilot UASB reactor, operated with simulated black water and an approximate HRT of three days. Removals were similar in both reactors operated with sewage. The average influent total COD, in pilot and full scale reactors, was 271 and 410 mg/L, respectively, and the average COD removal were 50.62 and 45.80%, respectively. With the parasitological test, there was almost no removal in both reactors and, in most cases, the number of (oo)cysts detected in the effluent was higher than in the influent. In the pilot reactor operated with black water, higher removals were observed. The total COD influent of this reactor ranged from 837 to 3269 mg/L and the average removal observed was 71.22%. In this reactor (oo)cysts removals were also higher, and the removal of Giardia cysts ranged from 67.73 to 93.69%, and in one of the trials, a 70% removal of Cryptosporidium spp was observed. It is believed that the best performance of this reactor is due to its high hydraulic retention time. The occurrence of (oo)cysts in the sludge of the three reactors was also evaluated, resulting in very high values of the order of 105 cysts/g of dry weight, in all of them. Anyway, in all this reactor, even the one with the highest efficiency, the effluent still had high concentrations of pollutants, necessitating a post treatment for the removal of remaining organic matter, solids and pathogens.
37

Viabilidade de pós-tratamento aeróbio de efluentes de reatores UASB visando reúso.

PAIVA, Laio Ariel Leite de. 13 September 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-09-13T17:38:25Z No. of bitstreams: 1 LAIO ARIEL LEITE DE PAIVA – DISSERTAÇÃO (PPGECA) 2016.pdf: 2279883 bytes, checksum: ddf555f3b9251dc01dc78d5b5fe5df71 (MD5) / Made available in DSpace on 2018-09-13T17:38:25Z (GMT). No. of bitstreams: 1 LAIO ARIEL LEITE DE PAIVA – DISSERTAÇÃO (PPGECA) 2016.pdf: 2279883 bytes, checksum: ddf555f3b9251dc01dc78d5b5fe5df71 (MD5) Previous issue date: 2016-02-29 / Capes / Sistemas anaeróbios modernos de tratamento de esgoto doméstico, embora bastante eficientes na remoção de matéria orgânica e sólidos em suspensão, não produzem um efluente com qualidade compatível com os padrões legais para descarga em corpos d’água receptores. Por essa razão esses sistemas têm que ser associados a unidades de pós-tratamento. Este trabalho trata de uma investigação experimental sobre a viabilidade de se aplicar o sistema de lodo ativado como uma alternativa do pós-tratamento, especificamente para o caso em que se prevê o efluente final para reúso. Na investigação experimental se usou um reator de bateladas sequenciais (RBS) em escala de bancada como unidade de pós-tratamento. Os resultados experimentais mostraram que a qualidade de efluente do sistema RBS de pós-tratamento em relação a matéria orgânica é muito boa. Na otimização do reator RBS se desenvolveu um modelo que permite estabelecer o tempo de permanência mínimo para o pós-tratamento em função de dois parâmetros básicos: a constante de utilização de material orgânico biodegradável pelas bactérias heterotróficas do lodo gerado no sistema de pós-tratamento e a sedimentabilidade deste lodo. A constante de utilização de material orgânico foi determinada por testes respirométrico. O lodo gerado no sistema de pós-tratamento surpreendentemente mostrou ter uma sedimentabilidade bem superior àquela normalmente encontrada em sistemas de lodo ativado tratando esgoto bruto, o que constitui um argumento sólido para a aplicação do sistema RBS na prática de pós tratamento do efluente do reator UASB. / Modern anaerobic systems for domestic sewage treatment, although very effective in removing organic matter and solid suspended, do not produce an effluent quality compatible with the legal standards for discharge into water bodies’ receivers. Therefore, such systems have to be associated with post treatment units. This paper deals with an experimental investigation into the feasibility of applying the activated sludge system as an alternative post-treatment, specifically for the case where intended use of the treated wastewater is reuse. In the experimental investigation research, a sequencing batch reactor (RBS) at bench scale was use as post treatment. The experimental results showed that the effluent quality of the RBS post treatment system in relation to organic matter was very good. An algorithm to optimize the RBS reactor was developed and allowed establishing the minimum residence time for the post-treatment in terms of two basic parameters: the utilization constant of biodegradable organic material by heterotrophic bacteria in the post-treatment system and the sludge settleability. The organic material using respirometric constant was determined from the oxygen uptake rate during the post treatment. The sludge from the post-treatment system surprisingly showed a much better settleability than what normally found in activated sludge systems treating raw sewage, which provides a strong argument for the application of the RBS system in practice post-treatment of the UASB reactor effluent.
38

Análise da eficiência e confiabilidade em 56 estações de tratamento de esgotos localizadas na região metropolitana de Fortaleza / Analysis of efficiency and reliability in 56 sewage treatment plants located in the metropolitan area of Fortaleza

Monteiro, Carlo Rannyêr Lopes 27 August 2009 (has links)
MONTEIRO, C. R. L. Análise da eficiência e confiabilidade em 56 estações de tratamento de esgotos localizadas na região metropolitana de Fortaleza. 2009. 77 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-22T17:31:11Z No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-29T14:51:15Z (GMT) No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) / Made available in DSpace on 2016-04-29T14:51:15Z (GMT). No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) Previous issue date: 2009-08-27 / Many Wastewater Treatment Plants (WWTPs) have serious design and / or operational problems that decrease efficiency levels and pollute the environment. Thus, it is important to have efficient and reliable WWTPs to meet the discharge standards. The purpose of this study was to analyze the efficiency and reliability of 56 wastewater treatment plants located in the Metropolitan Region of Fortaleza (MRF). About 13,100 data were evaluated, which were obtained from the Company of Water and Wastewater of Ceará (CAGECE). The data were from January 2005 to April 2009, divided in nine treatment technologies: septic tank (ST), septic tank followed by anaerobic filter (ST + ANF), septic tank followed by anaerobic filter and chlorination (ST + ANF + Cl), facultative pond (FP), facultative pond followed by a maturation pond (FP + MP), anaerobic pond followed by facultative pond and maturation pond (ANP + FP + MP), facultative aerated pond followed by facultative pond and maturation pond (FAP + FP + MP), UASB reactor (UASB) and finally UASB reactor followed by chlorination (UASB + Cl). To calculate the reliability of WWTPs and expected attendance percentage to accomplish effluent standards, a log-normal distribution was used. The average concentrations that the effluent from WWTP must have to meet the discharge standard were calculated for a given reliability level (95%), taking into account the coefficient of reliability (COR). The affluent values of pH, COD, TSS and TTC were compared to those typically found for this type of wastewater. The initial data analysis indicated problems in the monitoring frequency, inconsistencies and outliers, which were removed. The resulting data were used afterwards. The average efficiency values obtained in some technologies are lower than those of comparative literature, indicating operational problems. The highest efficiency values for COD, TSS and TTC were achieved with the technologies of ANP + FP + MP (91,4%), ANP + FP + MP (81.0%) and FAP + FP + MP (99.999%); the lowest efficiencies were obtained with ST + ANF (47.3%), ST (31.6%) and FP (95.36%), respectively. Regarding the coefficient of reliability calculation, the highest values for COD removal were obtained with the technologies of FAP + FP + MP (0.57) and UASB (0.57) and the lowest efficiencies were found with DD + ANF + Cl (0.40). For TSS, the best technologies were FAP + FP + MP (0.43) and FP (0.41) while the lowest CORs were obtained with ANP + FP + MP (0.26). The highest percentage values for accomplishing COD discharge standards were achieved with stabilization ponds, all above 98%, specially the technology FAP + FP + MP (99.9%). For TSS the highest percentages were also achieved with stabilization ponds, highlighting the technology of ANP + FP + MP (91%). The technologies of FAP + FP + MP and ANP + FP + MP provided the best efficiency values for COD, TSS and TTC, as well as the highest values of COR and percentages to accomplish discharge standards. / Diversas estações de tratamento de esgoto possuem sérios problemas de projeto e / ou operacionais os quais prejudicam o seu processo de tratamento e geram riscos de poluição dos recursos hídricos receptores. Assim, há a necessidade de tratamentos de esgotos cada vez mais eficientes e confiáveis para obedecerem aos padrões de descarte definidos em legislações ambientais cada vez mais restritivas. O objetivo do presente estudo foi analisar a eficiência e a confiabilidade de 56 estações de tratamento de esgotos situadas na Região Metropolitana de Fortaleza (RMF). Para tanto, foram avaliados cerca de 13.100 dados obtidos do monitoramento dos esgotos afluente e efluente às ETEs, durante o período de janeiro de 2005 a abril de 2009, as quais foram divididas em nove modalidades de tratamento, quais sejam: decanto-digestor (DD), decanto-digestor seguido de filtro anaeróbio (DD+FAN), decanto-digestor seguido de filtro anaeróbio e cloração (DD+FAN+Cl), lagoa facultativa (LF), lagoa facultativa seguida de lagoa de maturação (LF+LM), lagoa anaeróbia seguida por lagoa facultativa e lagoa de maturação (LAN+LF+LM), lagoa aerada facultativa seguida por lagoa facultativa e lagoa de maturação (LAF+LF+LM), reator UASB (UASB) e, por fim, reator UASB seguido de cloração (UASB+Cl). Para o cálculo da confiabilidade das ETEs e do percentual esperado de atendimento aos padrões de lançamento foi utilizada uma metodologia baseada em um modelo de distribuição log-normal dos dados, a qual determina concentrações médias que o efluente da ETE deve ter para obedecer aos padrões ambientais de lançamento para um determinado nível de confiabilidade (95%), levando em consideração o coeficiente de confiabilidade (CDC). Os valores afluentes de pH, DQO, SST e CTT foram comparados aos que são tipicamente encontrados para esse tipo de esgoto. Na avaliação inicial dos dados observou-se não haver freqüência de monitoramento, bem como, constatou-se a presença de inconsistências e outliers, os quais foram removidos. Os dados resultantes foram utilizados na seqüência da análise. Várias tecnologias de tratamento tiveram valores de eficiência inferiores ao que é registrado na literatura, indicando falhas operacionais no monitoramento das ETEs. Os maiores percentuais médios de remoção de DQO, SST e CTT foram alcançados pelas modalidades LAN+LF+LM (91,4%), LAN+LF+LM (81,0%) e LAF+LF+LM (99,999%) e os menores foram DD+FAN (47,3%), DD (31,6%) e LF (95,36%), respectivamente. Estes resultados mostram-se condizentes com os encontrados na literatura para todas as tecnologias de tratamento, exceto para remoção de SST por DD (31,6%) e DD+FAN (37,3%). No que se refere ao cálculo do coeficiente de confiabilidade foram obtidos para DQO os maiores valores pelas modalidades LAF+LF+LM (0,57) e UASB (0,57) e o menor valor para DD+FAN+Cl (0,40). Já para SST as tecnologias que se destacaram foram LAF+LF+LM (0,43) e LF (0,41) enquanto que o menor CDCs foi obtido por LAN+LF+LM (0,26). Os maiores percentuais esperados de atendimento às metas de descarte para DQO foram alcançados pelos tratamentos compostos por lagoas de estabilização, todos acima de 98%, destacando-se a tecnologia LAF+LF+LM (99,9%). Para SST os maiores percentuais obtidos também foram para as lagoas de estabilização, ressaltando a tecnologia LAN+LF+LM (91%). A tecnologia de tratamento DD foi a de menor percentual para DQO (1,2%) e para SST (2,0%). As modalidades de tratamento de esgotos domésticos LAF+LF+LM e LAN+LF+LM apresentaram um melhor desempenho considerando as eficiências médias de remoção de DQO, SST e CTT, como também maiores valores de CDC e percentuais esperados de atendimento às metas estabelecidas pela legislação.
39

Utilização de biofiltro aerado submerso no tratamento de efluentes de curtume submetido a processo de pré-tratamentos físico-químico e anaeróbio

Pereira, Eliane Leonora da Silva [UNESP] 22 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-22Bitstream added on 2014-06-13T18:58:46Z : No. of bitstreams: 1 pereira_els_me_ilha.pdf: 891055 bytes, checksum: 1f192c5619aab2493cb699997dee266a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os efluentes de curtume caracterizam-se por possuírem elevadas concentrações de compostos tóxicos, tais como: cromo, amônia, sulfatos e compostos orgânicos de baixa biodegradabilidade, por isso o tratamento desses efluentes é extremamente difícil. O presente trabalho tem como objetivo comparar a eficiência de tratamento de efluentes de curtume de duas linhas experimentais, em escala piloto, compostas por: reator UASB simplificado em forma de “Y” seguido de um Biofiltro Aerado Submerso (BF) e somente um BF, operadas simultaneamente, recebendo o mesmo efluente pré-tratado físico-quimicamente, por meio de um decantador de coluna e um floculador de manta de lodo. As linhas experimentais foram montadas junto à estação de tratamento de efluentes do curtume Fuga Couros Jales Ltda., na cidade de Jales-SP. O monitoramento das linhas de tratamento foi dividido em 4 etapas operacionais distintas: 1aetapa, a partida do sistema experimental, 2a etapa, adição do coagulante sulfato de alumino ferroso, 3a etapa, aumento da taxa de aeração nos BFs e 4a etapa, aumento do TDH nos reatores. Em cada etapa, foram analisados os seguintes parâmetros: alcalinidade total, acidez volátil, cromo total, DBObruta, DQObruta, fósforo total, nitrato e nitrito, nitrogênio total e amoniacal, oxigênio dissolvido, pH, sólidos, sulfato, sulfeto e temperatura. A eficiência média de remoção de DQO e DBO, na linha 1, foi de 66% e 73%, respectivamente. Na linha 2, a eficiência média de remoção de DQO foi de 47% e de DBO foi de 49%. A baixa eficiência de remoção de DQO, nas duas linhas, é devido as elevadas concentrações de sulfato afluentes ao tratamento biológico, resultando numa baixa relação DQO/SO4 2-, cerca de 1,2. Apesar da eficiência de remoção de DBO, na linha 1, estar próxima da porcentagem mínima estipulada na legislação estadual, cerca de 80%, o efluente das duas... / The tanning effluents are characterized for its have high concentrations of toxicity compounds, such as: chromium, ammonia, sulfates and organic compound of low biodegradability, the treatment for those effluents is extremely hard. The present work has as objective compared the tanning effluents treatment efficiency of two lines experimental devices on pilot scale, composed for: line 1 - simplified UASB reactor on “Y” form following the Submerged Aerated Biofilter (BF) and line 2, only the BF reactor were operated simultaneously, receiving the same effluent pre-treated by physic-chemical devices, through a column settler and a sludge blanket flocculator. The experimental devices were installed in the tanning effluents treatment plant of the Fuga Couros Jales Ltd., at the Jales-SP city of. The treatment lines was monitoring on four different operational steps: 1st.step, start-up of the experimental system, 2nd step, addition of the coagulant ferrous aluminum sulfate in the pre-treatment devices, 3rd step, increase of the aeration rate in BFs and 4th step, increase the reactors HDT. On each step, the following parameters were analyzed: total alkalinity, volatile acidity, total chrome, BOD, COD, total phosphorous, nitrate and nitrite, total nitrogen and ammonia, dissolved oxygen, pH, solids, sulfate, sulfide and temperature. The COD and BOD removal efficiency average, in the line 1, was 66% and 73%, respectively. In the line 2, the removal efficiency average of the COD was 47% and the BOD was 49%. This low removal efficiency of COD, at two lines, is due the high sulfate inlet concentrations to the biological treatment, that resulting in a low COD/SO4 2- rate, about 1.2. In spite of the removal BOD efficiency, at line 1, reach the minimum state legislation requisite, about 80%, the effluent of the two treatment lines doesn't attempt the effluents discharges patterns, established by the environmental legislation.
40

Influência da recuperação e retorno de lodo efluente sobre a capacidade e eficiência de tratamento de reatores UASB

Silva, Suênia da 22 June 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-10-31T13:53:06Z No. of bitstreams: 1 PDF - Suênia da Silva.pdf: 30135276 bytes, checksum: 5f7406e50f4c80ad94998275570d45c4 (MD5) / Made available in DSpace on 2018-10-31T13:53:06Z (GMT). No. of bitstreams: 1 PDF - Suênia da Silva.pdf: 30135276 bytes, checksum: 5f7406e50f4c80ad94998275570d45c4 (MD5) Previous issue date: 2017-06-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Resumo disponível do PDF da dissertação. / Resumo disponível do PDF da dissertação.