• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • Tagged with
  • 76
  • 76
  • 52
  • 42
  • 35
  • 32
  • 26
  • 20
  • 19
  • 17
  • 14
  • 13
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudo da codisposição de resíduos de fossas e tanques sépticos, com e sem a remoção prévia de gordura, no desempenho de tratamento de esgoto com reatores UASB / Codisposição study of waste and seotic tanks e repair, with and without prior removal of fat in the performance of sewage treatment with UASB reactors

Peixoto, Aline Vieira 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-08T18:01:37Z No. of bitstreams: 1 Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-08T20:24:04Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:33:30Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:22:47Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) / Made available in DSpace on 2014-12-16T09:22:49Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação-Aline Vieira Peixoto-2013.pdf: 3799528 bytes, checksum: 6a3b319d28bdad78b71d1bd2920717de (MD5) Previous issue date: 2013-07-15 / In Brazil, according to a national survey conducted by the Brazilian Institute of Geography and Statistics (IBGE, 2010), 44.8% of the municipalities use simplified domestic waste treatment systems such as septic tanks, rudimentary cesspools and dry pits. Such systems lead to the production of potentially polluting waste which requires suitable co-treatment. Several co-treatment alternatives have been proposed. The present study, which is part of the Program on Basic Sanitation Research (PROSAB), aimed to evaluate the interference caused by septage disposal from cesspools and septic tanks on the performance of the Upflow Anaerobic Sludge Blanket Reactor (UASB) in the city of Itumbiara- Goiás. The study took nine months and was divided into three distinct phases, in which the volumetric flow rate of wastewater from cesspools and septic tanks into the reactor ranged from 0.17% to 0.51%, displaying an intermediate phase of 0.34%.In the third phase, another fat flotation phase was added to the pre-treatment prior to discharge. During the study, we utilized all the waste volume from cesspools and septic tanks produced by the municipality and discharged into the Itumbiara Wastewater Treatment Plant (WWTP), already working at its full capacity. Statistical tests have proved that wastes from cesspool and septic tanks disposed into UASB reactors showed no significant difference in the final effluent quality. It was not evidenced also significant differences in the operation and maintenance of the reactors. The biological sludge from the UASB reactors got stable after being added the wastes (ratio VS/TS between 0.53 and 0.58 average). The receiving reactor’s begs had a worse efficiency but statistical tests showed that the difference was not significant when compared to the control reactors. It was observed in this study, there is no need for the pre-flotation of waste before being released at WWTP with UASB system. Thus the UASB is a viable alternative, but it is necessary to follow a protocol to establish criteria such as the waste application rate, the WWTP site for waste discharge, physical structure and people, as well as to choose for relevant parameters for the waste monitoring before co-treatment. / No Brasil, segundo Pesquisa Nacional de Saneamento Básico do Instituto Brasileiro de Geografia e Estatística (IBGE, 2010), 44,8% dos municípios utilizam sistemas simplificados para tratamento dos esgotos domésticos como: tanques sépticos, fossas rudimentares, fossas secas. Estes sistemas têm como consequência a produção de resíduos com potencial poluidor que necessitam de codisposição adequada. Diferentes alternativas de codisposição têm sido propostas. O presente trabalho, inserido na rede de pesquisa do Programa de Pesquisas em Saneamento Básico (PROSAB), tem como objetivos avaliar as interferências da disposição de resíduos de fossas e tanques sépticos no desempenho do Reator Anaeróbio de Manta de Lodo de fluxo ascendente ou Upflow Anaerobic Sludge Blanket (UASB), na cidade de Itumbiara-Goiás. O estudo teve duração de nove meses e foi dividido em três fases distintas, alterando a taxa de aplicações volumétrica dos resíduos de fossas e tanques sépticos no reator que variou de 0,17% a 0,51%, tendo uma fase intermediária de 0,34%, além de, na terceira fase, acrescentar mais uma etapa de flotação da gordura no tratamento preliminar, antes do lançamento dos resíduos. Durante a pesquisa, foi utilizado todo o volume de resíduos de fossas e tanques sépticos gerados pelo município e dispostos na ETE de Itumbiara que já trabalha com a carga máxima. Testes estatísticos comprovaram que a disposição de resíduos de fossas e tanques sépticos nos reatores UASB não apresentou diferença significativa na qualidade do efluente. Também não foram comprovadas alterações significativas na operação e manutenção dos reatores. O lodo biológico dos reatores UASB apresentou estabilidade após a disposição dos resíduos (relação SV/ST entre 0,53 a 0,58 em média). Os leitos do reator receptor apresentaram pior eficiência, porém testes estatísticos comprovaram que a diferença não foi significativa quando comparado com reatores testemunhos. Foi observou neste estudo, que não há necessidade da flotação prévia dos resíduos antes de serem lançados nas ETEs com sistema UASB. Portanto o UASB é uma alternativa viável, porém é necessário seguir um protocolo com critérios que estabelecerá a taxa de aplicação dos resíduos, o local na ETE onde será lançado o resíduo, estrutura física e de pessoal da ETE e determinar parâmetros de relevância para o monitoramento dos resíduos antes da codisposição.
62

Coagulação, floculação e flotação do efluente de reatores anaeróbios, tratando esgoto sanitário, com aplicação de diferentes dosagens de coagulante em função da variação da turbidez do esgoto afluente ao longo do dia / Coagulation, flocculation and flotation of anaerobic reactor effluents, treating sewage with the employment of different amounts of coagulant, according to the variation in sewage turbidity throughout the day

Gustavo Carneiro Ariano 11 September 2009 (has links)
Este trabalho avaliou a técnica de dosagem variável de coagulante em função da variação da turbidez do esgoto afluente a sistema de pós-tratamento por flotação do efluente de reatores UASB, localizado em Campinas, SP. Utilizou-se equipamento do tipo Flotateste para a flotação em escala de laboratório, sendo fixados os parâmetros: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Foram estudadas quatro velocidades de flotação (Vf), entre 8 à 20 cm/min. Na fase 1 da pesquisa estudou-se os coagulantes \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'Cl IND.3\', sendo determinadas as melhores dosagens para o horário das 12:00 horas. Posteriormente, na segunda fase, foram fixadas as melhores dosagens de cada coagulante e associada dosagens variadas de polímeros catiônico, aniônico e não iônico. Em seguida, na fase 3, foi realizada avaliação temporal, com ensaios realizados em seis diferentes horários do dia, estabelecendo uma razão entre a variação da turbidez afluente com a dosagem de coagulante. Finalmente, na quarta fase, foram aplicados quatro cenários de dosagens em doze horários diferentes ao longo de 24 horas. Para fase 1, verificou-se remoção de SST, DQO e fósforo para as dosagens de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77mg \'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% e 63,9%; PAC (8,45 mg \'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% e 82,7%; e \'FE\'CL IND.3\' (24,38 mg\'FE\'/L), 60,0%; 55,9% e 90,3%, respectivamente, para Vf = 16 cm/min. Na fase 2, determinou-se como melhor polímero, para ambos coagulantes, o polímero catiônico (PC), sendo associado às melhores dosagens definidas na fase1. Desta maneira na fase 2 verificou-se remoção de SST, DQO e fósforo para as dosagens associadas de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% e 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% e 88,8%; e \'FE\'CL IND.3\' + PC (24,38 mg\'FE\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectivamente. O cloreto férrico foi escolhido para ser utilizado nas fases seguintes devido a capacidade de precipitação de sulfeto o qual atingiu concentrações de até 15 mg/L no efluente anaeróbio. Em adição, foram fixadas as dosagens de polímero catiônico em 1,00 mg/L. Assim, para fase 3, a aplicação de dosagem variada entre 12,07 a 25,51 mg\'FE\'/L, para seis diferentes horários resultou em DQO < 50 mg/L e Fósforo < 0,50 mg/L para Vf = 16 cm/min. A aplicação de razão entre a dosagem de \'FE POT.+3\' e a turbidez afluente (RDmT) de 0,463 mg\'FE POT.+3\'/L.UNT (para turbidez < 50 UNT) e 0,244 mg\'FE POT.+3\'/L.UNT (para turbidez >50 UNT) na fase 4, garantiu para todas as velocidades de flotação estudadas turbidez < 15 UNT em 100% dos ensaios. Em adição, ao se realizar correlação entre a concentração de SST no efluente da FAD e a turbidez, chegou-se a conclusão de que este cenário atingiu remoção de lodo próxima a dosagem de \'FE\'CL IND.3\' máxima definidas na fase 3 (74 mg\'FE\'CL IND.3\'/L), com economia de 27,8% no consumo do coagulante. / This study evaluated the variable coagulant dosage technique according to the variation in turbidity of the influent sewage of the post-treatment flotation system of the UASB reactor effluents, located in Campinas, SP. Laboratory scale flotation equipment was used, with fixed parameters: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Four flotation velocities (Vf), between 8 a 20 cm/min, were studied. Phase 1 of the research studied the coagulants \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'CL IND.3\', being determined the best dosages for 12:00 pm. In phase 2 the best dosages of each coagulant were fixed and the associated cationic, anionic and nonionic polymer dosages were varied. In phase 3 experiments were taken at six different periods of the day, establishing a ratio between the variation in influent turbidity and coagulant dosage. In the fourth phase, four different dosage scenarios were applied at twelve different periods during a 24 hour day, to verify the best dosage scenario. In phase 1, the removal of TSS, COD and phosphorus was verified to the dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77 mg\'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% and 63,9%; PAC (8,45 mg\'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% and 82,7%; and \'FE\'CL IND.3\' (24,38 mg\'FE POT.+3\'/L), 60,0%; 55,9% e 90,3%, respectively, for Vf = 16 cm/min. In phase 2 the cationic polymer (PC) was determined to be the best polymer for both coagulants, when applied to the best dosages determined in phase 1. This way, in phase 2 the removal of TSS, COD and phosphorus was verified to the associated dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% and 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% and 88,8%; and \'FE\'CL IND.3\' + PC (24,38 mg\'FE POT.+3\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectively. Ferric chloride was chosen in the following phases due to its sulfide precipitation ability, reaching concentrations of up to 15 mg/L in the anaerobic effluent. In addition, the cationic polymer dosages were fixed to 1,00 mg/L. Thus, in phase 3, the dosage, varying between 12,07 to 25,51 mg\'FE POT.+3\'/L, applied to six different periods resulted, to Vf = 16 cm/min, in COD < 50 mg/L and phosphorus < 0,50 mg/L. The ratio between the dosage of \'FE POT.+3\' and the influent turbidity (RDmT) of 0,463 mg\'FE POT.+3\'/L.UNT (for turbidities < 50 NTU) and 0,244 mg\'FE POT.+3\'/L.UNT (for turbidities \'< OU =\' 50 NTU) when applied in phase 4, ensured, in 100% of the experiments, turbidity < 15 NTU for the studied flotation velocities. In addition, when correlating the concentration of TSS in FAD effluents with the turbidity, the conclusion was that this scenario reached a sludge removal close to that obtained by the maximum \'FE\'CL IND.3\' dosage defined in phase 3 (74 mg\'FE\'CL IND.3\'/L), with an economy of 27,8% in coagulant consumption.
63

Aplicação de reatores anaeróbios para remoção de sulfato de águas de drenagem ácida de minas

Renata Piacentini Rodriguez 30 April 2010 (has links)
O presente trabalho teve, por objetivo principal, analisar a remoção de sulfato em águas de drenagem ácida de minas em dois tipos de reatores anaeróbios, um com crescimento granular (UASB) e outro com biomassa aderida (RAHLF). Estudos anteriores publicados na literatura apresentam resultados positivos quanto ao tratamento anaeróbio de drenagem ácida de minas, entretanto, na maioria deles, é aplicado um tratamento preliminar à água residuária antes do tratamento principal. Esse trabalho avaliou a operação de reatores anaeróbios sem prévio tratamento da drenagem ácida sob diferentes variáveis. Para o reator anaeróbio horizontal de leito fixo (RAHLF), foram analisadas as variáveis relação DQO/\'SO IND.4\'POT.2-\', correção do pH afluente, carga de sulfato aplicada e a recirculação da fase líquida. Os resultados mostraram que a redução da carga de sulfato aplicada foi o fator determinante para os bons resultados de remoção, encontrados ao longo da operação dos reatores (70% de remoção de sulfato e 75% de remoção de DQO). A relação DQO/\'SO IND.4\'POT.2-\' também foi importante e quando utilizada a relação estequiométrica de 0,67, a eficiência de remoção de sulfato atingiu níveis superiores a 70% com pequeno acúmulo de ácido acético no efluente. Para a operação do reator anaeróbio de manta de lodo (UASB), as variáveis analisadas foram o volume da manta de lodo, a relação DQO/\'SO IND.4\'POT.2-\', a carga de sulfato aplicada e a recirculação da fase líquida. Como para o RAHLF, a redução da carga de sulfato aplicada foi essencial para o melhor funcionamento do UASB. A relação DQO/\'SO IND.4\'POT.2-\' de 1,0 promoveu melhora na eficiência do reator, quando comparada à relação estequiométrica e a recirculação no reator só foi positiva quando realizada com água de abastecimento, tendo o reator entrado em colapso quando a recirculação foi realizada com o efluente tratado. / The main objective of this work was to evaluate the sulfate removal from acid mine drainage in two types of anaerobic reactors, one with a granular sludge (UASB) and another with immobilized biomass (HAIB reactor). Previous published studies have showed positive results for the anaerobic treatment of acid mine drainage, however, in most of them, it was applied a pre-treatment operation. This study evaluated the operation of anaerobic reactors without pre-treatment of the acid mine drainage under different parameters. The parameters COD/\'SO IND.4\'POT.2-\' ratio, correction of affluent pH, sulfate loading and recirculation of the liquid phase were tested for horizontal-flow anaerobic immobilized biomass (HAIB) reactor. The results showed that the decrease in the sulfate loading was a determining factor for the successful sulfate removal found throughout the operation of the reactors. The COD/\'SO IND.4\'POT.2-\' ratio was also important and the removal efficiency of sulfate reached levels above 70% with a small accumulation of acetic acid in the effluent when using stoichiometric ratio of 0.67. For the operation of the upflow anaerobic sludge blanket (UASB) reactor, the parameters were the volume of the sludge blanket, the COD/\'SO IND.4\'POT.2-\' ratio, the sulfate loading and the recirculation of the liquid phase. Similarly ti the HAIB reactor, reducing the sulfate load was essential for obtaining better results. The COD/\'SO IND.4\'POT.2-\' ratio of 1.0 showed a improved sulfate removal efficiency for the UASB reactor when compared to stoichiometric ratio at 0.67 ant the recirculation in this reactor was only positive when carried out with tap water. The UASB reactor collapsed when recirculation was carried out whit the treated effluent.
64

Reator anaeróbio híbrido para tratamento de esgoto sanitário / Hybrid anaerobic reactor for domestic sewage treatment

Fernando Hermes Passig 11 March 2005 (has links)
Este trabalho de investigação refere-se ao uso do reator anaeróbio híbrido para tratamento de esgoto sanitário, com configuração baseada no reator anaeróbio de manta de lodo (UASB) com inclusão de: meio suporte sobre as calhas de coleta de gás (denominado reator anaeróbio híbrido - UAHB) e, também, meio suporte na zona de reação (denominado reator anaeróbio híbrido modificado - UAHBmod). Para o desenvolvimento desta pesquisa, no Campus I da USP de São Carlos-SP foram construídos dois reatores experimentais de 18,8 m3 cada: um reator UASB, com função de controle, e um reator UAHB. Primeiramente os reatores foram operados por período de 200 dias, com tempo de detenção hidráulica (TDH) de 6 h. Após serem inoculados, com 80 dias de operação, os reatores atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média de DQO, de 84% e 85% e de DBO de 87% e 91%, respectivamente para o UASB e o UAHB. Após esse período, os reatores foram submetidos a aumento da velocidade ascensional (Vasc) (mediante recirculação do efluente) de 0,78 m.h-1; 1,17 m.h-1; 1,56 m.h-1 e de 1,96 m.h-1. O UAHB mostrou ser menos susceptível ao aumento da Vasc do que o UASB. Além da análise da operação dos reatores, foram realizados os ensaios hidrodinâmicos e avaliada a estrutura da comunidade microbiana, por microscopia ótica, epifluorescência e pela técnica do DGGE. Após esse período preliminar, os reatores UAHB e UAHBmod, operados com TDH de 6h e Vasc de 0,78 m.h-1, atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média da matéria orgânica, de 71% e 76% em DQO, e de 72% e 87% em DBO, respectivamente para o UAHB e UAHBmod. Após este período, o reator UAHBmod, submetido a Vasc de 1,56 m.h-1, promoveu remoção de 74% de DQO, e de 87% de DBO. / This research refers to the use of a hybrid anaerobic reactor (UAHB) for domestic wastewater treatment. The configuration of this reactor is based on a sludge bed anaerobic reactor (UASB); in the first instance, a media support above the gas collection apparatus (also known as hybrid anaerobic reactor) was provided and later, a media support on the reaction zone (also known as hybrid modified anaerobic reactor - UAHBmod) was provided. Two reactors, with a volume of 18.8 m3, each, were built for this research at Campus I, USP in São Carlos - SP-Brazil. One UASB reactor acted as a control, and the other as a UAHB reactor. In the preliminary essays, the reactors were operated with 6h of hydraulic detention time (HDT) for 200 days. After inoculation, the reactors attained the apparent dynamic equilibrium state after 80 days of operation, with alkalinity generation, low volatile acids concentration and mean organic matter removal of 84% and 85% in terms of COD, and 87% and 91% in terms of BOD, for UASB and UAHB reactors, respectively. After this period, the reactors were submitted to an increasing in up velocity (Vup) of 0.78 m.h-1; 1.17 m.h-1; 1.56 m.h-1 and 1.96 m.h-1. The UAHB reactor showed lesser susceptibility for Vup increase than the UASB reactor. Hydrodynamic tests were also done on the reactors, in addition to routine operational analysis. The structure of the microbial community was evaluated by optical and epifluorescence microscopy, and the DGGE technique. After this step, the UAHB and the UAHBmod reactors were operated out 6h of HDT and Vup of 0.78 m.h-1. The reactors attained the apparent dynamic equilibrium state with alkalinity generation, low volatile acids concentration and mean organic matter removal of 71% and 76% in terms of COD, and 72% and 87% in terms of BOD for the UASB and UAHBmod reactors, respectively. After this period, the UAHBmod reactor was subjected to a Vup of 1.56 m.h-1 and achieved removal efficiencies of 74% COD and 87% BOD.
65

Ocorrência e remoção dos protozoários patogênicos Giardia spp. e Cryptosporidium spp. em sistemas de tratamento de esgoto sanitário / Occurrence and removal of patogenic protozoa Giardia spp. and Cryptosporidium spp. in sanitary sewage treatment systems

Priscila Ribeiro dos Santos 03 July 2015 (has links)
O propósito do presente estudo foi investigar e monitorar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. por diferentes processos de uma estação de tratamento de esgoto (ETE) em escala plena, composta basicamente por tratamento preliminar, reator UASB e flotador por ar dissolvido, e verificar a ocorrência desses protozoários no lodo do reator UASB e do flotador. Além disso, avaliou-se a remoção desses parasitos pelo processo de flotação por ar dissolvido em escala de bancada (equipamento Flotateste). Analisou-se a qualidade das amostras a partir de variáveis físicas e químicas, e pela detecção de microrganismos indicadores - E. coli, coliformes totais e Clostridium perfringens. Os métodos de detecção de protozoários se basearam nas etapas de concentração (tripla centrifugação ou filtração em membrana seguida de tripla centrifugação); purificação por separação imunomagnética (IMS); detecção por reação de imunofluorescência direta (RID). As recuperações de cistos variaram de 32,6 a 67,0 &#37; dependendo do método adotado, já para os oocistos as recuperações estiveram na faixa de 5,6 a 12,0 &#37;. Na ETE-Monjolinho foram detectadas significativas quantidades de cistos de Giardia spp. em 100% das amostras de esgoto analisadas, com concentração média de 1,89 x 104 e 2,35 x 102 cistos.L-1 no esgoto bruto e tratado, respectivamente. Já os oocistos de Cryptosporidium spp. foram detectados em 39,0 &#37; das amostras de esgoto, com concentração média de 1,35 x 102 oocistos.L-1 no esgoto bruto e 5,87 oocistos.L-1 em esgoto tratado (após flotador). A remoção global da ETE para remoção de Giardia spp. foi em média 2,03 log. O lodo do reator UASB e lodo do flotador apresentaram altas quantidade de (oo)cistos, constatando-se a tendência desses sistemas em concentrar os (oo)cistos por seus processos físicos. Algumas correlações significativas foram encontradas, como correlação entre a concentração de cistos no lodo e a variável sólidos totais, a concentração de cistos no esgoto bruto e as variáveis cor aparente, DQO total e particulada, e a concentração de cistos no efluente UASB e o microrganismo Clostridium perfringens. Diferentemente do flotador em escala plena, o processo do flotação por ar dissolvido em escala de bancada alcançou elevadas remoções médias de cistos de Giardia spp., entre 2,5 e 2,7 log nas diferentes condições de floculação estudadas. / The aim of this study was to investigate and monitor the removal of Giardia spp. cysts and Cryptosporidium spp. oocysts through different processes of a sewage treatment plant (STP) in full scale, consisted of preliminary treatment, UASB reactor, dissolved air flotator, and to verify the occurrence of the protozoa in the sludge derived from UASB reactor and flotator. Besides that, it was evaluated the removal of these parasites through the dissolved air flotation process in bench scale. It was analyzed the quality of the samples through physical and chemical variables, and detection of indicator microorganisms &#8211; E. coli, total coliforms and Clostridium perfringens. The detection methods of protozoa were based on steps of concentration (triple concentration or membrane filtration followed by triple concentration); purification by immunomagnetic separation (IMS); immunofluorescence assay (IFA). The recovery of cysts ranged from 32,6 to 67,0 &#37; according to the adopted method, while the recovery for the oocysts ranged from 5,6 to 12,0 &#37;. It was detected significant quantities of Giardia spp. cysts in 100 &#37; of the analyzed sewage samples at the STP-Monjolinho, with mean concentration of 1,89 x 104 e 2,35 x 102 cysts.L-1in raw sewage and treated sewage, respectively. The oocysts of Cryptosporidium spp. were detected in 39,0 &#37; of the sewage samples, with mean concentration of 1,35 x 102 oocysts.L-1 in raw sewage and 5,87 oocysts.L-1 in treated sewage (after flotator). The overall removal for Giardia spp. was on average of 2,03 log. The sludge from UASB reactor and flotator presented high quantities of (oo)cysts, implying the tendency of these systems to concentrate (oo)cysts through its physical processes. Some correlations were obtained, such as correlation between the concentration of cysts in the sludge and total solids, the concentration of cysts in the raw sewage and apparent color, total and particulate COD (chemical oxygen demand), and the concentration of cysts in the UASB effluent and the microorganism Clostridium perfringens. Unlike the full flotator, the dissolved air flotation in bench scale reached significant mean removal of Giardia spp. cysts, between 2,5 and 2,7 log according to the different flocculation conditions.
66

Resposta dinâmica dos reatores UASB (Upflow Anaerobic Sludge Blanket) submetidos a cargas senoidais / not available

Kátia Bakker Batista 16 November 2000 (has links)
Esta pesquisa consistiu na verificação do comportamento do reator UASB de bancada (volume igual a 10,5 litros), quando submetido a variações senoidais de vazão afluente, comparando-se com a eficiência no seu funcionamento com vazão constante, através de análises de amostras de afluentes e efluentes. O reator UASB utilizado foi montado no Laboratório de Processos Biológicos da EESC-USP dentro de uma câmara com temperatura constante de 30 ± 3°C, e alimentado com esgoto sintético, com DQO de 500 mg/l, 750 mg/l e 1000 mg/l. O reator foi inoculado em abril de 1999, com 3,5 litros de lodo anaeróbio proveniente de um reator compartimentado, também situado na EESC-USP. Devido à dificuldade de atingir um valor esperado para a eficiência de remoção de Matéria orgânica, foi dada nova partida no reator, em julho de 1999, desta vez com lodo proveniente de outro UASB. Após a segunda partida, o reator operou com vazão constante e DQO afluente em torno de 500 mg/l até setembro de 1999, com média de remoção de DQO bruta de 75% no período, passando-se, então, à fase de variação senoidal de vazão de forma que o máximo e o mínimo fossem de ±30%, ±45% e ±60% da vazão média. Para este regime, obteve-se 80% de eficiência média de remoção de DQO bruta. Os valores de pH, alcalinidade e ácidos voláteis foram praticamente constantes durante a operação. Os perfis de remoção de DQO ao longo do dia mostraram uma pequena queda na eficiência do reator, aproximadamente 1,5 vezes o tempo de detenção hidráulica médio (8 horas), após os máximos de vazão para o regime de variação de vazão de ±30% e ±45% e 2,5 vezes o tempo de detenção hidráulica médio, para variação e ±60%. O mesmo experimento foi repetido para DQO afluente de 1000 mg/l e obteve-se, em média, eficiências de 65% de remoção de DQO. / This research consisted in the UASB reactor performance verification when it was submitted to sine-based variations of loading rate, in comparison to its normal operation. The UASB reactor used was set up at the Biological Process Laboratory of EESC-USP, inside a camera with temperature of 30°C ± 3°C. It was fed with synthetic sewage (COD = 500, 750 and 1000 mg/l). After start-up, the reactor was operated with constant loading rate (COD = 500 mg/l) until September 1999. The organic matter removal average in this period was 75%. Then, it was initiated the phase of sine-based variation loading rate (±30%, ±45% and ±60%). In this regime, it was obtained a medium gross COD removal efficiency of 80%. The pH values, alkalinity and volatile acids were practically constant during the operation. The COD removal profiles during the day showed a subtle fall in the reactor efficiency after 1.5 times the medium hydraulic detection time, for the loading rate variation of ±30% and ±45%. For ±60% variation, the answer time was approximately 2.5 times the medium hydraulic detection time. The efficiency of gross COD removal stay however over 78,53% until the experiment 9, witch showed that the reactor can stand the loading rate variations. The efficiency of filtered COD removal decreased on the second experiment, came back to the initial values and decreased again. The values of variation didn\'t surpass 6,6% for gross COD and 8,43% for filtered COD.
67

Minimização de afluentes e avaliação de sistema biológico de tratamento de águas residuárias em uma indústria de conservas vegetais / Effluent minimization and evaluation of wastewater biologic system treatment in a vegetable-cannery industry

Huber, Charles Soares 10 December 2007 (has links)
Made available in DSpace on 2014-08-20T13:32:51Z (GMT). No. of bitstreams: 1 dissertacao_charles_huber.pdf: 1046471 bytes, checksum: a81eb3b445f28a007ba73c7b94476592 (MD5) Previous issue date: 2007-12-10 / The addition a chemical surfactant in the sodium hydroxide solution was evaluated in the peach peeling process. The results were compared to the traditional process, without chemical addition. It could be observed reduction from 57.14% in the sodium hydroxide consumption, 49.18% in wastewater generation of the fruit washing process and 42.81%, 16.02%, 45.45%, 24.16% and 31.82%, in the loads of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total Kjeldahl nitrogen (TKN), total suspended solids (TSS) and the settleable solids (SS), respectively. The fruit-cannery wastewaters must be treated. There are several processes that can be used for the removal of materials and chemicals that can degrade the environment. An upflow anaerobic sludge blanket (UASB) of a cannery industry (fruits and vegetables) was evaluated. The system was assessed for 712 days and the efficiency of total DQO removal was evaluated. The start-up began with a mean organic loading rate (OLR) of 0.40kgDQO.m-3.d-1, and achieved a maximum OLR of 5.29kgDQO.m-3.d-1 in 307 days. The mean removal of total DQO was 86.87%. This study showed that even with the seasonality of production, the UASB reactor is a good alternative for the secondary treatment of fruit-cannery industry / Avaliou-se a adição de um surfactante químico à solução de hidróxido de sódio, utilizada no processo de descasque químico do pêssego. Os resultados obtidos foram comparados com o do processo tradicional, sem a adição desta substância. Observou-se reduções de 57,14% no consumo de hidróxido de sódio, 49,18% na geração de efluente líquido, no processo de lavagem da fruta e 42,81%, 16,02 %, 45,45%, 24,16% e 31,82%, nas cargas da demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO), nitrogênio total Kjeldahl (NTK), sólidos suspensos totais (SST) e dos sólidos sedimentáveis (SS), respectivamente. As águas residuárias originadas no processo de industrialização da fruta devem ser tratadas em uma estação de tratamento de efluentes. Existem diversos processos que podem ser utilizados para a remoção dos materiais e substâncias potencialmente prejudiciais ao meio ambiente. Monitorou-se a partida e a operação de um reator anaeróbio de fluxo ascendente (UASB) tratando efluentes de uma indústria de conservas de frutas e vegetais. O sistema foi monitorado por 712 dias e avaliou-se a eficiência da remoção de demanda química de oxigênio (DQO) total. O início da operação do reator foi com uma carga orgânica volumétrica (COV) aplicada de 0,40kgDQO.m-3.d-1, atingindo-se uma COV máxima de 5,29kgDQO.m-3.d-1 em 307 dias. A remoção de DQO total foi de 86,87%. Este estudo mostrou que mesmo com a sazonalidade de produção, os reatores UASB são uma boa alternativa de tratamento secundário para a indústria conserveira
68

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Medeiros, Raphael Corrêa 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
69

Geração de metano em reator UASB: avaliação de parâmetros de monitoramento para controle do processo de tratamento anaeróbio de vinhaça / Methane generation in a UASB reactor: evaluation of monitoring parameters for control of anaerobic treatment process of vinasse

Longo, Rodrigo Rodrigues 29 May 2015 (has links)
Com o propósito de explorar o potencial de geração de metano a partir de vinhaça de cana-de-açúcar e propor procedimentos de controle do processo anaeróbio, foi utilizado um reator UASB (Upflow Anaerobic Sludge Blanket) em escala piloto, equipado de separador gás-sólido-líquido modificado e sem recirculação de efluente. A unidade foi inoculada com lodo granular e utilizou-se substrato concentrado (DQO de 20 g.L-1) para sua alimentação. O reator foi submetido a cargas orgânicas volumétricas (COV) de 0,7 a 7 KgDQO.m-3.d-1, durante 300 dias de operação. O procedimento operacional baseou-se no aumento de carga por escalonamento da vazão de alimentação em função da manutenção de variação inferior a 10% para a eficiência do sistema. Para o tamponamento da vinhaça de alimentação, no início da operação utilizou-se 1g NaHCO3.g-1DQOafluente, com redução gradativa até 0,125g NaHCO3.g-1DQOafluente. O monitoramento do desempenho do processo anaeróbio se deu pela avaliação dos parâmetros: eficiência de remoção de DQO, pH, alcalinidade, ácidos voláteis, razão alcalinidade intermediária/alcalinidade parcial, razão Prop:Ac, vazão de metano e porcentagem de metano no biogás. O reator UASB apresentou valor médio de eficiência de remoção de DQO de 92±4,4%, para cargas aplicadas entre 0,7 e 4,8 KgDQO.m-3.d-1. A maior produção média de metano observada durante o período operacional foi 5 m3CH4.m-3 de vinhaça aplicada para cargas orgânicas entre 4,1 e 5,6 KgDQO.m-3.d-1. A produção de biogás apresentou valor médio de metano de 70±7% para 1 a 5,6 Kg DQO.m-3.d-1. A operação do reator com cargas aplicadas acima de 5,6 KgDQO.m-3.d-1 gerou menor produção de biogás, redução na porcentagem de metano e aumento da carga de ácidos voláteis efluente, assim como queda na eficiência de remoção de DQO. Devido ao acréscimo de carga (0-2 para 4-6 KgDQO.m-3.d-1), a variação da concentração para cada tipo de ácido foi: acético (56±70 para 216±121 mg.L-1), propiônico (26±28 para 165±150 mg.L-1) e butírico (4±7 para 60±18 mg.L-1). Notou-se que a relação entre as concentrações de ácido propiônico e ácido acético (razão Prop:Ac) pode ser utilizada como parâmetro de monitoramento da estabilidade do reator. A elevação de COV de 3,9 a 6,4 KgDQO.m-3.d-1acarretou alteração na razão Prop:Ac de 0,8 a 1,75, corroborando descontroles do processo anaeróbio associado à queda de eficiência na geração de metano. / In order to explore the potential of methane generation from sugarcane vinasse and propose procedures for the anaerobic process control, was utilized a pilot scale UASB reactor (Upflow Anaerobic Sludge Blanket), equipped with modified gas-solid-liquid separator and without recirculation of effluent. The unit was inoculated with granular sludge and concentrated substrate was used (COD 20 g.L-1) for feeding. The reactor was submitted to volumetric organic load (VOL) from 0.7 to 7 KgCOD.m-3.d-1, during 300 days of operation. The reactor operation was based on the increase of load by staggering the feed flow in function of the maintenance of variation lower than 10% for the system efficiency. For buffering the feedings vinasse was used 1g NaHCO3.g-1CODinfluent at the beginning of the operation, with gradual reduction to the value of 0.125 g NaHCO3.g-1CODinfluent. The monitoring of the anaerobic process performance was due to the evaluation of the following parameters: efficiency of COD removal pH, alkalinity, intermediate alkalinity/partial alkalinity ratio; Prop:Ac ratio, methane flow and percentage of methane in the biogas. The UASB reactor demonstrated a COD average removal efficiency of 92±4.4%, to applied loads between 0.7 and 4.8 KgCOD.m-3.d-1. The highest average methane production observed during the operational period was 5 m3CH4.m-3 of vinasse applied for organic loads between 4.1 and 5.6 KgCOD.m-3.d-1. The biogás production demonstrated a methane average of 70±7% for 1 to 5.6 KgCOD.m-3.d-1. The reactor operation with loads up to 5.6 KgCOD.m-3.d-1 caused lower production of biogas, reduction in the percentage of methane and increase for effluent volatile acids load, as well as decrease of COD removal efficiency. Due to the additional load (0-2 to 4-6 KgCOD.m-3.d-1), the change in concentration for each type of acid was: acetic acid (56±70 to 216±121 mg.L-1), propionic acid (26±28 to 165±150 mg.L-1) and butyric acid (4±7 to 60 ± 18 mg.L-1). It was noted that the relationship between the concentrations of propionic acid and acetic acid (ratio Prop:Ac) may be used as a monitoring parameter of the reactor stability. The increase in VOL of 3.9 to 6.4 KgCOD.m-3.d-1 caused change in the Prop:Ac ratio of 0.8 to 1.75, confirming the upsets on the anaerobic process associated with efficiency drop in methane generation.
70

Emprego de coagulante à base de tanino em sistema de pós-tratamento de efluente de reator UASB por flotação / Use of tannin-based coagulant in exhaust post-treatment of UASB reactor effluent by flotation

Pelegrino, Eloá Cristina Figueirinha 03 June 2011 (has links)
O presente trabalho teve como objetivo principal a avaliação da eficiência de remoção de carga orgânica, fósforo e sólidos em suspensão de sistema de flotação tratando esgoto sanitário pré-tratado em reatores UASB, da ETE Monjolinho da cidade de São Carlos/SP, e coagulado com tanino associado ou não a polímeros sintéticos. Os ensaios com variação de dosagem de coagulante Tanino e polímeros (polímero catiônico, polímero não-iônico e polímero aniônico) foram realizados em escala de laboratório, com o uso do equipamento flotateste. Em todos os ensaios foram fixados os valores de gradiente de velocidade na mistura rápida (800/s) e na floculação (90/s), ao tempos de detenção na mistura rápida (20 s) e na floculação (15 min) e, a pressão de saturação 5 Bar e a razão de recirculação (17%). Durante os ensaios com unidade de flotação em escala de bancada foram avaliados três valores de velocidades de flotação: 12,0 cm/min, 16,0 cm/min e 20,0 cm/min. Os ensaios foram divididos em duas fases: a fase 1 teve como objetivo analisar a resposta do sistema de flotação com o emprego do coagulante Tanino no tratamento do efluente do reator UASB da ETE Monjolinho (fase 1A) e também determinar as duas dosagens do coagulante Tanino mais adequadas para o tratamento do efluente de UASB da ETE Monjolinho para cada polímero testado (fase 1B). As fases 1A e 1B foram realizadas com efluente coletado às 8:00 h e 14:00 h, respectivamente. A fase 2 teve como objetivo a busca da dosagem ótima de tanino dentro de uma faixa mais estreita de valores, assim como a verificação do melhor tipo e dosagem de polímero sintético (não-iônico, aniônico e catiônico) para ser associado ao coagulante tanino. Na fase 1A, verificou-se que a flotação foi efetiva para remoção de cor aparente mesmo para dosagem nula de coagulante Tanino. Quanto à turbidez, verificou-se efeito marcante da adição de dosagem crescente de coagulante no aumento da eficiência de remoção desse parâmetro. Após a obtenção dos resultados da fase 1B, foram escolhidas para a fase 2 as duas menores dosagens de coagulante capazes de promover redução da turbidez em pelo menos 85%. Além destas duas dosagens, foram avaliados na fase 2 outras 3 dosagens compreendidas entre elas. Sendo assim, na fase 2 foram estudadas as doses de 65, 75, 85, 95 e 105 mg/L de coagulante, cada qual associada a seis dosagens de cada um dos polímeros estudados. Entre os tratamentos empregados, pôde-se verificar maior eficácia do polímero não-iônico e do polímero catiônico para o tratamento por flotação, associado ao coagulante tanino. O conjunto de dosagem de coagulante tanino e polímero mais vantajoso, ou seja, menor dosagem de tanino que, associada a polímero, apresentou remoção satisfatória dos parâmetros estudados, foi 65 mg/L de Tanino e 2,0 mg/L de polímero catiônico, atingindo remoções de 95,2% de turbidez (Residual de 3,65 NTU), 82,1% de cor aparente (Residual de 98 mgPT/L), 49,2% de fósforo total (Residual de 3,2 mg/L), 80,7% de DQO (Residual de 25 mg/L) e 87,9 % de SST (Residual de 13 mg/L) nas condições encontradas na época dos ensaios, para o pós-tratamento por flotação de efluente de reator UASB da ETE Monjolinho, São Carlos/SP. / The main objective of this work is the evaluation of the efficiency of removal of organic load, phosphorus and suspended solids in the flotation system treating domestic wastewater pretreated in UASB reactors, of the Monjolinho Wastewater Treatment Plant (WWTP) of Sao Carlos, SP and clotted with tannin alone or combined with synthetic polymers. Tests varying tannin dosage of coagulant and polymer (cationic polymer, nonionic polymer and anionic polymer) were performed on a batch scale, using flotatest. In all the tests were fixed the values of rapid mix (800/s) and flocculation (90/s) velocity gradients, the rapid mix (20 s) and flocculation (15 min) times, saturation pressure (5 Bar) and recycle rate (17%). During the test in the flotation bench scale unity three values of flotation velocities were evaluated: 12.0 cm/min, 16.0 cm/min and 20.0 cm/min. The tests were divided in two phases: the objective of phase 1 was to examine the response of the flotation system with the use of tannin coagulant in the treatment of Monjolinho WWTP UASB effluent (Phase 1A) and also determine the two most suitable dosages of tannin coagulant for the treatment of wastewater from the Monjolinho WWTP UASB tested for each polymer (phase 1B). Phases 1A and 1B were performed with wastewater collected at 8:00 h and 14:00 h, respectively. The objective of phase 2 was to find the optimum dosage of tannin within a narrower range of values, as well as verification of the optimal type and dosage of synthetic polymer (non-ionic, anionic and cationic) to be associated with the tannin coagulant. In phase 1A, it was found that flotation was effective for apparent color removal even to zero coagulant dosage tannin. As for turbidity, there is a marked effect when increasing the coagulant dose, which increased the removal efficiency of this parameter. After obtaining the results of Phase 1B, were chosen for phase 2 two low coagulant dosages which can promote reduction of turbidity by 85%. Besides the two dosages obtained in phase 1B, in phase 2 were evaluated other three between them. Thus, in phase 2 were studied coagulant doses of 65, 75, 85, 95 and 105 mg/L, each one associated with six doses of each one of the studied polymers. Among the treatments employed, it could be seen that the non-ionic polymer and the cationic polymer were the most efficient for treatment by coagulation associated with tannin in flotation. The set of tannin coagulant dosage and polymer which showed satisfactory removal of parameters was 65 mg/L of Tannin with 2.0 mg/L of cationic polymer, reaching 95.2% removal of turbidity, 83% of color apparent, 49.2% of total phosphorus, COD 80.7% and 87.9% of TSS under the conditions found at the time of testing, for post-treatment of Monjolinho WWTP UASB effluent by flotation.

Page generated in 0.0388 seconds