• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1783
  • 671
  • 320
  • 269
  • 233
  • 136
  • 46
  • 29
  • 27
  • 22
  • 18
  • 17
  • 17
  • 14
  • 13
  • Tagged with
  • 4467
  • 892
  • 594
  • 565
  • 561
  • 458
  • 446
  • 355
  • 348
  • 334
  • 333
  • 333
  • 332
  • 323
  • 294
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
801

Bayesian Modeling of Pitting Corrosion in Steam Generators

Mao, Dan 08 1900 (has links)
Steam generators in nuclear power plants experienced varying degrees of under-deposit pitting corrosion. A probabilistic model to accurately predict pitting corrosion is necessary for effective life-cycle management of steam generators. This thesis presents an advanced probabilistic model of pitting corrosion characterizing the inherent randomness of the pitting process and measurement uncertainties of the in-service inspection (ISI) data obtained from eddy current (EC) inspections. A Bayesian method is developed for estimating the model parameters. The proposed model is able to estimate the number of actual pits, the actual pit depth as well as the maximum pit depth, which is the main interest of the pitting corrosion model. A MATLAB program of the Markov chain Monte Carlo technique is developed to perform the Bayesian estimations. Simulation experiments are performed to check the behavior of the Bayesian method. Results show that the MCMC algorithm is an effective way to estimate the model parameters. Also, the effectiveness and efficiency of Bayesian modeling are validated. A comprehensive case study is also presented on the in-service inspection data of pitting corrosion in a steam generator unit. The Weibull distribution is found to be an appropriate probability distribution for modeling the actual pit depth in steam generators.
802

Predicting and Prolonging the Service Life of Weathering Steel Highway Structures

Damgaard, Neal 14 August 2009 (has links)
Weathering steel is a high-strength, low-alloy steel which has been proven to provide a significantly higher corrosion resistance than regular carbon steel. This corrosion resistance is a product of the small amounts of alloying elements added to the steel, which enable it to form a protective oxide layer when exposed to the environment. The main advantage of its use in bridges is that, under normal conditions, it may be left unpainted, leading to significantly reduced maintenance and environmental costs. Weathering steel has been a material of choice for highway structures for almost half a century, and a very large number of structures have been constructed with it. Although its use has for the most part been successful, it has also become evident that, in circumstances where there is the presence of salt and sulphur oxides, its performance is deficient. In these situations the corrosion penetration rate is much higher than expected, and the oxide layer forms in thick layers. This presents an added risk, since these layers flake off and fall onto the roadway. The degree of corrosion on structures can be very different, even if the structural type, location, and climate are similar. Therefore the focus of the thesis is on the lifespan of weathering steel highway structures. Primarily this research is concerned with the effect of corrosion on the integrity of these structures, as well as ways of quantifying corrosion loss and protecting the structure from further corrosion. In order to determine the lifespan of weathering steel highway structures subject to different rates of corrosion, a probabilistic structural analysis program has been developed to assess the time-dependent reliability of the structure. This program used iterative Monte Carlo simulation and a series of statistical variables relating to the material, loading, and corrosion properties of the structure. A corrosion penetration equation is used to estimate thickness loss at a selected interval, and the structural properties of the bridge are modified accordingly. The ultimate limit states of shear, moment, and bearing, and the fatigue limit state of web breathing, are taken into account. Three types of structures are examined: simply-supported box and I-girder composite bridges, and a two-span box girder bridge. Based on the structural analysis of the corroding bridge structures presented herein, it can be seen that corrosion to the weathering steel girders can cause reduced service lives of the structures. I-girder bridges are shown to be more susceptible to corrosion than box girder bridges, with continuous box girder bridges showing the best performance. The amount of truck traffic does not affect the reliability of the bridge. The short-span and high strength steel bridges are more susceptible to corrosion loss, primarily because their girders have thinner sections. A two-lane bridge also has better performance than the wider bridges because the weight of the barriers and sidewalks is carried by fewer girders, so these girders are stockier. The web breathing limit state is less significant than the combined ultimate limit states. Lastly, and most importantly, inspection data from a highway bridge is used to demonstrate the benefit that can be derived from using field data to update the time-dependent reliability. The ultrasonic thickness gauge (UTG) is a common tool for thickness measurement of steel sections. When used to measure weathering steel, this instrument provides accurate data about the depth of corrosion pits, but not their lateral dimensions. The measurement does not include the corrosion layer on the opposite side of the plate from the one being measured; however, if the corrosion layer is on the measured face, a disproportionate increase in the measured thickness can be seen. In order to prevent or minimize corrosion loss, the steel is currently painted, a process with several environmental and financial disadvantages. Therefore, three novel protection methods have been assessed in a cyclic corrosion test: a zinc metallizing, an aluminum-zinc-indium alloy metallizing, and a zinc tape with a PVC topcoat. All these coatings are designed to act not just as barriers, but also as sacrificial anodes. The test was run for 212 24-hr cycles, over the course of which the all the coatings were proven effective at protecting the steel substrate, regardless of steel type and surface roughness and pretreatment. In conclusion, the threat to all types of weathering steel highway structures by contaminant-induced corrosion is significant, but inspection data permits a more accurate prediction of time-dependent reliability for a structure, and protective coatings are a promising method of slowing the advance of corrosion.
803

Distribution System Planning and Reliability Assessment under High DG Penetration

Atwa, Yasser January 2010 (has links)
With power system restructuring, continuous growth of demand, and deregulation, small, scattered generators referred to as Distributed Generation (DG) are predicted to play a key role in the power distribution system. Moreover, among the different types of DG units, it is widely accepted that renewable DG units are the key to a sustainable energy supply infrastructure, since they are both inexhaustible and non-polluting. However the intermittent nature and the uncertainties associated with the renewable resources create special technical and economical challenges that have to be comprehensively investigated in order to facilitate the deployment of these DG units in the distribution system. The objective of the work proposed in this thesis is to tackle some of the challenges associated with the increased penetration of renewable DG units into existing distribution systems. This includes the study of the impact of different renewable DG units on the supply adequacy of the distribution system, and the development of planning technique that optimally allocate renewable DG units into the distribution system. Furthermore, a methodology is proposed to check the feasibility of implementing energy storage system (ESS) into the distribution system to mitigate the problems associated with the high penetration of renewable DG units. These problems include the maximum reverse power flow limit, the equipment rating limit, and the voltage limit on each bus. The first step toward the accomplishment of this work is to model the random behaviour of the renewable resources (i.e. wind speed and solar irradiance). Here, different approaches are proposed to model the random behaviour of both wind speed and solar irradiance, either chronologically or probabilistically. Among those approaches are a novel technique of annual wind speed estimation based on a constrained Grey predictor, and a new implementation of the probability density function (pdf) of the clearness index so as to model solar irradiance using Monte Carlo Simulation (MCS). Supply adequacy of distribution systems is assessed based on well-being criteria during different modes of operation (i.e. grid-connected mode and islanding mode), using analytical and (MCS) techniques. During the grid-connected mode, from the load perspective, the substation transformers act as generating units. Therefore, supply adequacy of distribution systems is assessed by considering that the generating units of the distribution system are the substation transformers and the DG units. During the islanding mode of operation, the island is acting as a small autonomous power system (SAPS) and the most important issue during this mode of operation is to determine the probability of the island to be successful (the DG power output within the island matches the load) or a failure (there is a deficit in power generation). The focus of the model developed to optimally allocate the renewable DG units in existing distribution systems is to minimize annual energy losses and at the same time, avoid any violation of the system constraints under any operating condition. The methodology is based on generating a probabilistic generation-load model that combines all possible operating conditions of the renewable DG units with their probabilities, hence accommodating this model in a deterministic planning problem. The objective function of the planning formulation is to minimize annual energy losses; whereas the constraints include the voltage limits, the feeders’ capacity, the maximum penetration limit, and the discrete size of the available DG units. The objective of the methodology proposed for allocating an ESS into distribution systems with high penetration (greater than 20% of the feeder capacity) of renewable energy is to maximize the benefits for both the DG owner and the utility. This is done by sizing the ESS to accommodate the entire surplus of renewable energy, and then allocating it within the system in order to minimize the annual cost of the electricity.
804

Composite power system well-being analysis

Aboreshaid, Saleh Abdulrahman Saleh 01 January 1997 (has links)
The evaluation of composite system reliability is extremely complex as it is necessary to include detailed modeling of both generation and transmission facilities and their auxiliary elements. The most significant quantitative indices in composite power system adequacy evaluation are those which relate to load curtailment. Many utilities have difficulty in interpreting the expected load curtailment indices as the existing models are based on adequacy analysis and in many cases do not consider realistic operating conditions in the system under study. This thesis presents a security based approach which alleviates this difficulty and provides the ability to evaluate the well-being of customer load points and the overall composite generation and transmission power system. Acceptable deterministic criteria are included in the probabilistic evaluation of the composite system reliability indices to monitor load point well-being. The degree of load point well-being is quantified in terms of the healthy and marginal state indices in addition to the traditional risk indices. The individual well-being indices of the different system load points are aggregated to produce system indices. This thesis presents new models and techniques to quantify the well-being of composite generation and, direct and alternating current transmission systems. Security constraints are basically the operating limits which must be satisfied for normal system operation. These constraints depend mainly on the purpose behind the study. The constraints which govern the practical operation of a power system are divided, in this thesis, into three sets namely, steady-state, voltage stability and transient stability constraints. The inclusion of an appropriate transient stability constraint will lead to a more accurate appraisal of the overall power system well-being. This thesis illustrates the utilization of a bisection method in the analytical evaluation of the critical clearing time which forms the basis of most existing stability assessments. The effect of employing high-speed-simultaneous or adaptive reclosing schemes is presented in this thesis. An effective and fast technique to incorporate voltage stability considerations in composite generation and transmission system reliability evaluation is also presented. The proposed technique can be easily incorporated in an existing composite power system reliability program using voltage stability constraints that are constructed for individual load points based on a relatively simple risk index. It is believed that the concepts, procedures and indices presented in this thesis will provide useful tools for power system designers, planners and operators and assist them to perform composite system well-being analysis in addition to traditional risk assessment.
805

Reliability/cost evaluation of a wind power delivery system

Patel, Jaimin 03 April 2006 (has links)
Renewable energy policies, such as the Renewable Portfolio Standard, arising from increasing environmental concerns have set very ambitious targets for wind power penetration in electric power systems throughout the world. In many cases, the geographical locations with good wind resources are not close to the main load centers. It becomes extremely important to assess adequate transmission facility to deliver wind power to the power grid. <p>Wind is a highly variable energy source, and therefore, transmission system planning for wind delivery is very different from conventional transmission planning. Most electric power utilities use a deterministic n-1 criterion in transmission system planning. Deterministic methods cannot recognize the random nature of wind variation that dictates the power generated from wind power sources. This thesis presents probabilistic method to evaluate the contribution of a wind power delivery system to the overall system reliability. The effects of site-specific wind regime, system load, transmission line unavailability, and redundancy on system reliability were studied using a basic system model. The developed method responds to the various system parameters and is capable of assessing the actual system risks. <p>Modern power system aims to provide reliable as well as cost effective power supply to its consumers. Reliability benefits, environmental benefits and operating cost savings from wind power integration should be compared with the associated investment costs in order to determine optimum transmission facility for wind power delivery. This thesis presents the reliability/cost techniques for determining appropriate transmission line capacity to connect a wind farm to a power grid. The effect of transmission system cost, line length, wind regime, wind penetration and customer interruption cost on the optimum transmission line sizing were studied using a basic system model. The methodology and results presented in this thesis should be useful in transmission system planning for delivering wind power to a power system.
806

Reliability-based load management of the Red Deer River bridge

Jackson, Kristopher 05 October 2007 (has links)
This thesis presents the results of an investigation into the evaluation of a selected test bridge using instrumentation to obtain site-specific factors contributing to the evaluation, with the ultimate objective of improving the estimate of the bridges reliability in order to assess allowable loading more accurately. The experimental portion of the research program involved instrumenting the test bridge with strain gauges, and recording field measurements using two forms of loading. The analytical portion of the research program involved the analysis of the bridge in the as-designed state, based on the design drawings and specification, followed by a re-analysis of the bridge using the site-specific factors measured on-site. The bridge was evaluated using methods outlined in the Canadian Highway Bridge Design Code CAN/CSA-S6-00 (CSA 2000). <p>The test bridge is located near the community of Hudson Bay, Saskatchewan. The bridge is constructed of steel-reinforced concrete, and there are three, three-span arch-shaped girders. There are also external steel bars added after initial construction to increase the midspan bending moment resistance. In total, 45 strain gauges were placed on the middle spans of the three girders to record strain induced by two forms of loading: controlled loading, in which a truck of known weight and dimensions was driven over the bridge in a number of pre-determined configurations, and in-situ loading, in which normal truck traffic was used. The current allowable loading on the bridge is a gross vehicle weight of 62.5 t, although increasing the allowable loading to 110 t has been proposed, along with two strengthening alternatives to make this increased loading feasible. <p>To provide a base-line analysis for comparison purposes, the bridge was first evaluated based strictly on information taken from the design drawings and specifications. The evaluation was performed using the load and resistance factor method, in which load and resistance factors were used to account for uncertainty, as well as by the mean load method, in which statistical properties of the variables parameters included in the design were used to account for uncertainty. The result of the load and resistance factor method was a live load capacity factor, indicating the overall rating of the bridge. In addition to the live load capacity factor, the mean load method was also used to determine the reliability index. The results of the as-designed analysis showed that the mean load method gave more conservative estimates of the bridge capacity. Furthermore, it was determined that, based on these assessments, the bridge would not have sufficient capacity to carry the proposed 110 t truck loads.<p>The bridge was re-evaluated using site-specific factors with the mean load method. Using the measured strains, statistical parameters were determined for live load effects, distribution factors, dynamic load allowance, and resistance. Statistical parameters that could not be obtained readily through testing were obtained from the literature. The results indicated that code-predicted estimates of a number of factors were highly conservative. Flexural and shear load effects in the girders were found to be less than 15% of the theoretical predictions, as a result of apparent arching action in the girders, generating significant axial forces. For this arching action to occur, horizontal restraint was required at the supports, either through unanticipated restraint in the bearings, or tension tie action of the tensile girder reinforcement. Furthermore, the dynamic amplification was found to be less than 1.0. The resulting reliability indices indicated that the bridge would be safe under the proposed increased allowable loading (110 t). <p>Finite element models were used to confirm the dynamic amplification observations and examine the effects of different degrees of bearing restraint. The model showed results similar to those measured for dynamic amplification. It was found that if the bearings were to become completely fixed against horizontal translation, the bridge would become overloaded as a result of increased shear effects, demonstrating the need for proper bearing maintenance. <p>An analysis of relative costs was completed to determine the most cost-effective solution for hauling logs. Assumptions were made regarding truck and maintenance and operating costs. The results indicated that the most economic solution was to use the method outlined in the research to increase the allowable loading on the bridge to 110 t, over the strengthening alternatives and simply leaving the bridge in the current state.
807

Reliable data delivery in wireless sensor networks

Yang, Bofu 21 June 2010 (has links)
Wireless sensor networks (WSN) have generated tremendous interest among researchers these years because of their potential usage in a wide variety of applications.<p> Sensor nodes are inexpensive portable devices with limited processing power and energy resources. Sensor nodes can be used to collect information from the environment, locally process this data and transmit the sensed data back to the user.<p> This thesis proposes a new reliable data delivery protocol for general point-to-point data delivery (unicasting) in wireless sensor networks. The new protocol is designed that aims at providing 100% reliability when possible as well as minimizing overhead and network delay. The design of the new protocol includes three components. The new protocol adopts a NACK-based hop-by-hop loss detection and recovery scheme using end-to-end sequence numbers. In order to solve the single/last packet problem in the NACK-based approach, a hybrid ACK/NACK scheme is proposed where an ACK-based approach is used as a supplement to the NACK-based approach to solve the single/last packet problem. The proposed protocol also has a new queue management scheme that gives priority to new data. By introducing the idea of a Ready_Bit and newer packet first rule in the transmission queue, nodes can detect and recover lost packets in parallel with the normal data transmission process. The performance of the new protocol is tested in a Crossbow MicaZ testbed. Experimental results show that the new protocol performs well under various system and protocol parameter settings.
808

Reliability evaluation of electric power system including wind power and energy storage

Hu, Po 18 November 2009 (has links)
Global environmental concerns associated with conventional energy generation have led to the rapid growth of wind energy applications in electric power systems. Growing demand for electrical energy and concerns associated with limited reserves of fossil fuels are also responsible for the development and increase in wind energy utilization. Many jurisdictions around the world have set high wind penetration targets in their energy generation mix.<p> The contribution of wind farms to the overall system reliability is limited by the uncertainty in power output from the highly variable energy source. High wind penetration can lead to high risk levels in power system reliability and stability. In order to maintain the system stability, wind energy dispatch is usually restricted and energy storage is considered to smooth out the fluctuations and improve supply continuity. The research work presented in this thesis is focused on developing reliability models for evaluating the benefits associated with wind power and energy storage in electric power generating systems. An interactive method using a sequential Monte Carlo simulation technique that incorporates wind farm and energy storage operating strategies is developed and employed in this research. Different operating strategies are compared and the resulting benefits are evaluated. Important system impacts on the reliability benefits from wind power and energy storage are illustrated. Hydro facilities with energy storage capability can alleviate the impact of wind power fluctuations and also contribute to system adequacy. A simulation technique for an energy limited hydro plant and wind farm coordination is developed considering the chronological variation in the wind, water and the energy demand. The IEEE four-state model is incorporated in the developed technique to recognize the intermittent operation of hydro units. Quantitative assessment of reliability benefits from effective utilization of wind and water resources are conducted through a range of sensitivity studies. The information provided and the examples illustrated in this thesis should prove useful to power system planners and wind developers to assess the reliability benefit from utilizing wind energy and energy storage and the coordination between wind and hydro power in electric power systems.
809

Refining the accelerometric measurement of physical activity

Esliger, Dale Winfield 26 April 2011 (has links)
Advances in electronic sensor technologies have led to the increased use of accelerometers for measuring physical activity and sedentary behaviours. Accelerometers overcome many of the inherent limitations of other measurement methods; for example, unlike self-reported instruments, accelerometers are free from random and systematic errors introduced by respondents and interviewers, cultural tradition, and language. However, accelerometers have their own set of limitations; for example, not all accelerometers are created equal and raw accelerometer data require significant data mining procedures in order to yield meaningful outcome variables. Therefore the overall purpose of this three study dissertation was to determine the impact accelerometer model has on the development of a comprehensive physical activity and sedentary behaviour profile and to design and apply novel profiling methods in an order to gain new insights into childrens physical activity.<p> Study One Purpose: To determine which of the three most commonly used accelerometer models has the best intra- and inter-instrument reliability using a mechanical laboratory setup. Secondly, to determine the effect acceleration and frequency have on these reliability measures. Methods: Three experiments were performed. In the first, five each of the Actical, Actigraph, and RT3 accelerometers were placed on a hydraulic shaker plate and simultaneously accelerated in the vertical plane at varying accelerations and frequencies. Six different conditions of varying intensity were used to produce a range of accelerometer counts. Reliability was calculated using standard deviation, standard error of the measurement, coefficient of variation, and intraclass correlation coefficients. In the second and third experiment, 39 Actical and 50 Actigraph accelerometers were put through the same six conditions. Results: Experiment One showed poor reliability in the RT3 (intra- and inter-instrument CV > 40%). Experiments Two and Three clearly indicated that the Actical (CVintra = 0.5%; CVinter = 5.4%) was more reliable than the Actigraph (CVintra = 3.2%; CVinter = 8.6%). Variability in the Actical was negatively related to the acceleration of the condition while no relationship was found between acceleration and reliability in the Actigraph. Variability in the Actigraph was negatively related to the frequency of the condition while no relationship was found between frequency and reliability in the Actical. Conclusion: Of the three accelerometer models measured in this study, the Actical had the best intra- and inter-instrument reliability. However, discrepant trends in the variability of Actical and Actigraph counts across accelerations and frequencies preclude the selection of a superior model. More work is needed to understand why accelerometers designed to measure the same thing, behave so differently.<p> Study Two The accurate measurement of habitual physical activity is fundamental to the study of the relationship between physical activity and health. However, many physical activity measurement techniques produce variables accurate to only the day level, such as total energy expenditure via self-report questionnaire, pedometer step counts or accelerometer measurements of minutes of moderate to vigorous physical activity. Monitoring technologies providing more detailed information on physical activity/sedentary behaviour can now be used to explore the relationships between health and movement frequency, intensity, and duration more comprehensively. This paper explores the activity and sedentary profile that can be acquired through objective monitoring, with a focus on accelerometry. Using previously collected objective data, a detailed physical activity profile is presented and case study examples of data utilization and interpretation are provided. The rich detail captured through comprehensive profiling creates new surveillance and study possibilities and could inform new physical activity guidelines. Data are presented in various formats to demonstrate the dangers of misinterpretation when monitoring population adherence to Canadas Physical Activity Guidelines. Recommendations for physical activity and sedentary profiling are provided and future research needs identified.<p> Study Three Purpose: This study explored the influence of modernity on the physical activity behaviours (e.g. intensity and timing) of children. Methods: Children aged 8-13 years living a traditional lifestyle (Old Order Amish; OOA n=68, Old Order Mennonite; OOM n=120) were compared with children living a contemporary lifestyle (rural Saskatchewan; RSK n=132 and urban Saskatchewan; USK n=93). Physical activity was objectively assessed for seven consecutive days using Actigraph 7164 accelerometers. Custom software was used to reduce the raw accelerometer data into standardized outcome variables. Results: On weekdays there were group differences in moderate physical activity between all lifestyle groups (OOA > OOM > USK > RSK). On the weekend, the group differences in moderate physical activity persisted between, but not within, lifestyle groups (OOA = OOM > USK = RSK). During school hours, all groups had similar activity and sedentary timings; however, they differed in magnitude with the OOA and OOM being both more sedentary and more active. Compared to in school, the OOA and OOM children had 44% lower sedentary time out of school compared to only 15% lower for RSK and USK children. Conclusions: Though cross-sectional, these data suggest that contemporary/modern living is associated with lower levels of moderate and vigorous intensity physical activity compared to lifestyles representative of earlier generations. Analyzing the physical activity and sedentary patterns of traditional lifestyle groups such as the OOA and OOM can provide valuable insight into the quantity and quality of physical activity necessary to promote health.<p> General Conclusions: Together, these three studies will help contribute to the generation of best practices in the accelerometric profiling of both physical activity and sedentary behaviours.
810

Electroplated Compliant High-Density Interconnects For Next-Generation Microelectronic Packaging

Lo, George Chih-Yu 20 August 2004 (has links)
Dramatic advances are taking place in the microelectronic industry. The feature size continues to scale down and it is expected that the minimum feature size on the integrated circuit is expected to reach 9 nm by 2016, and there will be more than 8 billion transistors on a 310 cm² chip, according to various available roadmaps. Subsequently, this reduction in feature size would require the first-level input-output interconnects to decrease in pitch size to meet the increased number of transistors on the chip. Also, to minimize the on-chip interconnect delay, development of low-K dielectric/copper will become increasingly common in future devices. However, due to the low fracture strength of low-K dielectric, it is essential that the first-level interconnects exert minimal force on the die pads and therefore, do not crack or delaminate the low-K dielectric material. It is also preferable to have a wafer-level packaging approach to facilitate test-and-burn in and to produce known-good dies. Based on these growing demands from the microelectronics industry, there is a compelling need to develop innovative interconnect technologies. This thesis aims to develop one such innovative interconnect — G-Helix interconnect. G-Helix is a scalable lithography-based wafer-level electroplated compliant interconnect that has the potential to meet the fine-pitch first-level chip-to-substrate interconnect requirements. The three-mask fabrication of G-Helix is based on lithography, electroplating and molding (LIGA-like) technologies, and this fabrication can be easily integrated into large-area wafer-level fine-pitch batch processing. In this work, the fabrication, assembly, experimental reliability testing, and numerical physics-based modeling of the G-Helix interconnects will be presented. The fabrication of the interconnects will be demonstrated at 100μm pitch on a 20 x 20 mm die in a class 10/1000 cleanroom facility. The wafers with compliant interconnects will be singulated into individual dies and assembled on substrates using Pb/Sn eutectic solder. The assembly will then be subjected to air-to-air thermal cycling between 0℃and 100℃ and the reliability of the compliant interconnect will be assessed. In addition to the thermo-mechanical reliability testing, some of the dies with free-standing interconnects will also be used for measuring the compliance of the interconnects by compressing with a nanoindenter. In parallel to the experimental research, a numerical analysis study will also be carried out. The numerical model will use direction-, temperature, time-dependent, and time independent material constitutive properties as appropriate. The thermo-mechanical fatigue life of the compliant interconnect assembly will be determined and compared with the experimental data. Recommendations will be developed for further enhancement of reliability and reduction in pitch size.

Page generated in 0.0644 seconds