• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 1
  • Tagged with
  • 38
  • 38
  • 38
  • 36
  • 31
  • 31
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional / Analysis of the viability of the application of CAD-CAM technology of rapid prototyping in manufacturing removable partial dentures compared to the conventional method

Ichi, Alvaro Luis 11 November 2010 (has links)
A tecnologia CAD-CAM vem sendo aplicada há mais de uma década para a confecção de trabalhos protéticos odontológicos e bucomaxilofaciais. A tecnologia de prototipagem rápida permite a construção de um modelo em tempo reduzido por meio do sistema CAD (computer-aided design) e CAM (computer-aided manufacturing), permitindo absoluta fidelidade ou discrepância desprezível. Assim, o objetivo deste trabalho será analisar a viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível, comparando-a ao método convencional. O projeto visa à obtenção de melhores benefícios funcionais e econômicos aos pacientes, trazendo à luz inovações tecnológicas, novos conceitos e melhores condições para o restabelecimento da saúde bucal. A metodologia empregada partiu da reprodução de um modelo padrão de uma arcada inferior parcialmente desdentada, classe III Mod-1 de Kennedy. Quatro pilares metálicos foram posicionados no local dos primeiros pré-molares e molares. Com o auxílio de um scanner digital 3D, obteve-se um modelo virtual da arcada, no qual foi modelado digitalmente o desenho da estrutura protética. Oito estruturas de PPR foram confeccionadas utilizando-se a tecnologia de prototipagem rápida e, posteriormente fundidas em liga de cobalto-cromo. Outras oito estruturas foram confeccionadas seguindo o protocolo para confecção de PPR de forma convencional. A análise comparativa foi realizada avaliando o peso perdido. A avaliação por peso está dividida em dois grupos. O primeiro, denominado Grupo AP (Ajuste e Polimento), possui quatro estruturas convencionais (Grupo AP-C) e quatro prototipadas (Grupo AP-P). O segundo, chamado Grupo A (Ajuste) realizado somente ajuste sem polimento, com quatro estruturas convencionais (Grupo A-C) e quatro prototipadas (Grupo A-P). Análise comparativa por peso mensurou a porcentagem de material perdido necessário para o adequado assentamento dos apoios das estruturas metálicas pela técnica convencional e por prototipagem em seus respectivos descansos. Os resultados mostraram que as estruturas foram passíveis de serem obtidas pela tecnologia proposta. A análise comparativa mostrou que o Grupo AP-P apresentou um desgaste médio de 0,9826g, correspondente a 13,5188% de seu peso inicial; o Grupo AP-C apresentou um desgaste médio de 0,7529g, correspondente a 12,4380% de seu peso inicial. A análise por meio de Teste t independente mostrou uma diferença estatisticamente significante com valor de p=0,0386, p<0,05. No Grupo A-P houve um desgaste médio de 0,1045g, correspondente a 1,4455% de seu peso inicial. No Grupo A-C houve um desgaste médio de 0,1473g, correspondente a 2,3188% de seu peso inicial. A análise por meio de Teste t independente mostrou uma diferença estatisticamente significante com valor de p=0,0038, p<0,01. Foi viável a aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível. / The CAD-CAM technology has been applied for more than a decade for the manufacturing of dental and maxillofacial prosthesis. The rapid prototyping technology allows for the construction of a model in reduced time by using the CAD (computer-aided design) and CAM (computer-aided manufacturing) systems, allowing absolute preciseness or negligible discrepancies. Thus, the purpose of this research is to analyze the viability of the application of the CAD-CAM technology of rapid prototyping in the manufacturing of removable partial dentures(RPD) compared to the conventional method. The purpose of this research was to obtain functional and financial benefits for the patient, demonstrate recent technological advances and concepts and improve the resources for the reestablishment of oral health. The methodology used to determine effectiveness of the CAD-CAM system started with the reproduction of a Kennedy Class III Modification 1 cast of an inferior partially edentulous dental arch,. Four metallic pins were positioned in place of the first premolars and molars. A 3D scanner was used to construct a virtual model of the arch on which the design of the prosthetic structure was digitally formed. Eight RPD frameworks were manufactured using the fast prototyping technology with subsequent casting with a cobalt-chromium alloy; eight others followed the standard RPD waxing/casting procedure. The analysis between procedures evaluated the weight lost when each of the respective frameworks were processing. The results were divided into two groups. The first group, named AP (Adjusted and Polished), had four standard (Group AP-C) and four prototyped (Group AP-P) frameworks. The second group, named A (Adjusted), also includes eight frameworks (four standard, Group A-C, and four prototyped, Group A-P) which were cast and adjustted but not polished. In the comparative analysis, the variation of the weight determined the percentage of the material lost needed for the adequate settling of the rests in their respective seat with the standard and prototyped methods. The data indicated that frameworks can be obtained with the proposed technology. The comparative analysis results showed an average wear of 0.9826g on Group AP-P, corresponding to 13.5188% of its initial weight. In the Group AP-C, average wear was 0.7529g, 12.4380% of its initial weight. With the independent t-test, a significant statistical difference of p=0.0386, p<0.05 was found. The average wear for Group A-P wasf 0,1045g, 1.4455% of its initial weight, while in Group A-C the value was 0.1473g, corresponding to 2.3188% of its initial weight. The independent t-test analysis for these cases shows a significant statistical difference of p=0.0038, p<0.01. The application of the CAD-CAM technology of fast prototyping is viable for the manufacturing of removable partial dentures.
22

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro /

Lopes, José Fernando Scarelli. January 2003 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Eunice Teresinha Giampaolo / Banca: João Henrique Nogueira Pinto / Resumo: O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below) / Mestre
23

Análise da viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível comparando-a ao método convencional / Analysis of the viability of the application of CAD-CAM technology of rapid prototyping in manufacturing removable partial dentures compared to the conventional method

Alvaro Luis Ichi 11 November 2010 (has links)
A tecnologia CAD-CAM vem sendo aplicada há mais de uma década para a confecção de trabalhos protéticos odontológicos e bucomaxilofaciais. A tecnologia de prototipagem rápida permite a construção de um modelo em tempo reduzido por meio do sistema CAD (computer-aided design) e CAM (computer-aided manufacturing), permitindo absoluta fidelidade ou discrepância desprezível. Assim, o objetivo deste trabalho será analisar a viabilidade da aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível, comparando-a ao método convencional. O projeto visa à obtenção de melhores benefícios funcionais e econômicos aos pacientes, trazendo à luz inovações tecnológicas, novos conceitos e melhores condições para o restabelecimento da saúde bucal. A metodologia empregada partiu da reprodução de um modelo padrão de uma arcada inferior parcialmente desdentada, classe III Mod-1 de Kennedy. Quatro pilares metálicos foram posicionados no local dos primeiros pré-molares e molares. Com o auxílio de um scanner digital 3D, obteve-se um modelo virtual da arcada, no qual foi modelado digitalmente o desenho da estrutura protética. Oito estruturas de PPR foram confeccionadas utilizando-se a tecnologia de prototipagem rápida e, posteriormente fundidas em liga de cobalto-cromo. Outras oito estruturas foram confeccionadas seguindo o protocolo para confecção de PPR de forma convencional. A análise comparativa foi realizada avaliando o peso perdido. A avaliação por peso está dividida em dois grupos. O primeiro, denominado Grupo AP (Ajuste e Polimento), possui quatro estruturas convencionais (Grupo AP-C) e quatro prototipadas (Grupo AP-P). O segundo, chamado Grupo A (Ajuste) realizado somente ajuste sem polimento, com quatro estruturas convencionais (Grupo A-C) e quatro prototipadas (Grupo A-P). Análise comparativa por peso mensurou a porcentagem de material perdido necessário para o adequado assentamento dos apoios das estruturas metálicas pela técnica convencional e por prototipagem em seus respectivos descansos. Os resultados mostraram que as estruturas foram passíveis de serem obtidas pela tecnologia proposta. A análise comparativa mostrou que o Grupo AP-P apresentou um desgaste médio de 0,9826g, correspondente a 13,5188% de seu peso inicial; o Grupo AP-C apresentou um desgaste médio de 0,7529g, correspondente a 12,4380% de seu peso inicial. A análise por meio de Teste t independente mostrou uma diferença estatisticamente significante com valor de p=0,0386, p<0,05. No Grupo A-P houve um desgaste médio de 0,1045g, correspondente a 1,4455% de seu peso inicial. No Grupo A-C houve um desgaste médio de 0,1473g, correspondente a 2,3188% de seu peso inicial. A análise por meio de Teste t independente mostrou uma diferença estatisticamente significante com valor de p=0,0038, p<0,01. Foi viável a aplicação da tecnologia CAD-CAM por prototipagem rápida na confecção de estrutura metálica da prótese parcial removível. / The CAD-CAM technology has been applied for more than a decade for the manufacturing of dental and maxillofacial prosthesis. The rapid prototyping technology allows for the construction of a model in reduced time by using the CAD (computer-aided design) and CAM (computer-aided manufacturing) systems, allowing absolute preciseness or negligible discrepancies. Thus, the purpose of this research is to analyze the viability of the application of the CAD-CAM technology of rapid prototyping in the manufacturing of removable partial dentures(RPD) compared to the conventional method. The purpose of this research was to obtain functional and financial benefits for the patient, demonstrate recent technological advances and concepts and improve the resources for the reestablishment of oral health. The methodology used to determine effectiveness of the CAD-CAM system started with the reproduction of a Kennedy Class III Modification 1 cast of an inferior partially edentulous dental arch,. Four metallic pins were positioned in place of the first premolars and molars. A 3D scanner was used to construct a virtual model of the arch on which the design of the prosthetic structure was digitally formed. Eight RPD frameworks were manufactured using the fast prototyping technology with subsequent casting with a cobalt-chromium alloy; eight others followed the standard RPD waxing/casting procedure. The analysis between procedures evaluated the weight lost when each of the respective frameworks were processing. The results were divided into two groups. The first group, named AP (Adjusted and Polished), had four standard (Group AP-C) and four prototyped (Group AP-P) frameworks. The second group, named A (Adjusted), also includes eight frameworks (four standard, Group A-C, and four prototyped, Group A-P) which were cast and adjustted but not polished. In the comparative analysis, the variation of the weight determined the percentage of the material lost needed for the adequate settling of the rests in their respective seat with the standard and prototyped methods. The data indicated that frameworks can be obtained with the proposed technology. The comparative analysis results showed an average wear of 0.9826g on Group AP-P, corresponding to 13.5188% of its initial weight. In the Group AP-C, average wear was 0.7529g, 12.4380% of its initial weight. With the independent t-test, a significant statistical difference of p=0.0386, p<0.05 was found. The average wear for Group A-P wasf 0,1045g, 1.4455% of its initial weight, while in Group A-C the value was 0.1473g, corresponding to 2.3188% of its initial weight. The independent t-test analysis for these cases shows a significant statistical difference of p=0.0038, p<0.01. The application of the CAD-CAM technology of fast prototyping is viable for the manufacturing of removable partial dentures.
24

Efeito de pastilhas higienizadoras efervescentes nos componentes da prótese parcial removível / Effect of effervescent denture tablets on the components of partial removable denture

Vasconcelos, Glenda Lara Lopes 09 February 2018 (has links)
Este estudo avaliou os efeitos de pastilhas efervescentes na superfície de liga de cobalto cromo (Co-Cr) e resina termopolimerizável, simulando um período de até 5 anos de imersão, como também analisar sua ação antimicrobiana. A partir de uma matriz metálica, padrões de cera circulares (12 x 3 mm) foram obtidos e fundidos em liga de Co-Cr (DeguDent®). As amostras foram imersas em: Polident 3 minutes® (P3M), Steradent® (St), Polident for Partials® (PP), Efferdent® (Ef), Corega Tabs® (CT), Nitradine® (Ni), Fixodent® (Fi) e Kukident® (K). Foi avaliada a resistência à corrosão (Ecorr, Ipass) (n=5) por meio do Potenciostato/Galvanostato. Foram realizadas análises qualitativas complementares com Microscópio Eletrônico de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS). Após o ensaio de corrosão, cada disco metálico foi incluído em mufla preparada por matrizes circulares de cera (20 x 5 mm), incorporando-o à resina acrílica termopolimerizável (Clássico Ltda®). Os grupos das 4 pastilhas que apresentaram a menor taxa de corrosão e da água destilada (controle) (n=9) foram analisados quanto à rugosidade da superfície metálica e da resina acrílica (Sa, &micro;m) por meio de microscopia confocal a laser. Foram avaliadas a alteração de cor (&Delta;E) da resina por meio de espectrocolorímetro no início e após a simulação de ½, 1, 2, 3, 4 e 5 anos e alteração de massa (g), no início e final, em balança de alta precisão. Para avaliação antimicrobiana, por meio da contagem de Unidades Formadoras de Colônia (UFC/mL), os espécimes mistos foram contaminados com biofilme misto composto por: S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) e C. glabrata (Cg) e, posteriormente, imersos nas soluções higienizadoras, onde foram semeados em meios específicos para contagem das UFC. De acordo com os resultados obtidos (&alpha;=0,05), P3M causou a menor taxa de corrosão e Ni, o menor potencial de corrosão. Com o MEV, verificou-se evidenciação da microestrutura da liga metálica. Quanto à rugosidade superficial do metal, CT (p=0,009) e Ni (p=0,036) causaram aumento na rugosidade em relação ao tempo (Friedman). Na resina, houve aumento da rugosidade após 5 anos (p<0,01). Entre as soluções (Kruskal-Wallis), não houve diferença para ambos os materiais. Não houve diferença na cor da resina acrílica, tanto em relação às soluções (Kruskal Wallis) quanto aos tempos (Friedman). Não foram observadas alterações de massa (Kruskal-Wallis). Quanto à ação antimicrobiana (Kruskal-Wallis), Ni propiciou redução de UFC de Sm (p=0,001). Conclui-se que, embora todas as pastilhas efervescentes não tenham alterado a superfície do metal e da resina acrílica de maneira significativa, nenhuma apresentou ação antimicrobiana contra os microrganismos avaliados do biofilme misto; somente Ni reduziu a quantidade de S. mutans / The aim of this study were: to evaluate the effects of denture cleansers on the surface of cobalt chromium (Co-Cr) and heat-polymerized acrylic resin, simulating a period until 5 years of immersion, as well as to analyze its antimicrobial action. From a metal matrix, disc-shaped wax patterns (12 x 3 mm) were made and later were casting in Co-Cr alloy (DeguDent&trade;). The specimes were immersed in: Polident 3 minutes&trade; (P3M), Steradent&trade; (St), Polident for Partials&trade; (PP), Efferdent&trade; (Ef), Corega Tabs&trade; (CT), Nitradine&trade; (Ni), Fixodent&trade; (Fi) and Kukident&trade; (K). The corrosion resistance (Ecorr, Ipass) (n = 5) was evaluated by Potentiostat / Galvanostat. Further qualitative analyzes were performed with scanning electronic microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). After the corrosion test, each metal disk was included in heat-cured acrylic resin (Clássico Ltda&trade;) using moulds previously prepared from circular wax matrices (20 x 5 mm). The four dentures cleansers with the lowest corrosive potential were analyzed for surface roughness of the metal and acrylic resin (Sa, &micro;m) by laser confocal microscopy. The color change (&Delta;E) of the resin was evaluated by means of a spectrocolorimeter at the beginning and after the simulation of ½, 1, 2, 3, 4 and 5 years and mass change (g), at the beginning and end, in high-precision balance. For antimicrobial evaluation, the mixed specimens (n = 9) were contaminated with multispecies biofilm [S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) and C. glabrata (Cg)] and subsquently immersed in denture cleansers, where they were seeded in specific CFU / mL media. According to the results obtained (&alpha;=0.05), there was a significant difference: P3M presented the lowest corrosion rate and Ni, the lowest corrosion potential. According to SEM, the tablets effervescent provided evidence of the microstructure of the alloy. As for the surface roughness in the metal surface, CT (p = 0.009) and Ni (p = 0.036) showed increase in roughness in relation to time (Friedman). At the resin surface, the roughness growed after 5 years. Among the solutions (Kruskal-Wallis), there was no difference for both materials. There was no difference in the color of the acrylic resin (&delta;E), both for solution (Kruskal-Wallis), and for time (Friedman). Differences in weight weren\'t observed (Kruskal-Wallis). In antimicrobial action (Kruskal-Wallis), Ni group showed significant reduction for Sm (p=0.001). It\'s concluded that, although all the denture cleansers didn\'t significantly changed the surface of the metal and acrylic resin, none showed antimicrobial action against the evaluated microorganisms of the mixed biofilm; only Ni reduced the amount of S. mutans
25

Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitos

Santos, Ciandrus Moraes de Freitas [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1 santos_cmf_me_araca.pdf: 1084188 bytes, checksum: 0a96538ac84e5167cd37297d47e91a27 (MD5) / Universidade Estadual Paulista (UNESP) / A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions.
26

Falhas e complica??es com o uso de pr?tese parcial remov?vel inferior de extremidade livre bilateral

T?rres, Ana Clara Soares Paiva 11 March 2014 (has links)
Made available in DSpace on 2014-12-17T15:43:56Z (GMT). No. of bitstreams: 1 AnaCSPT_DISSERT.pdf: 2140417 bytes, checksum: 8ecf2918cdf8a508e2b68c89eeb3e3ea (MD5) Previous issue date: 2014-03-11 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls / Objetivo: Verificar a frequ?ncia e tipo de complica??es relacionadas ? pr?tese parcial remov?vel (PPR) inferior, classe I de Kennedy, ao longo do tempo. Materiais e M?todos: Este estudo observacional foi composto por uma amostra de 65 usu?rios de PPR inferior em arcos Classe I de Kennedy e pr?tese total superior, reabilitados no Departamento de Odontologia da Universidade Federal do Rio Grande do Norte (UFRN). Os pacientes foram acompanhados por meio de controles peri?dicos nos per?odos de 60 dias, 6 meses e 1 ano desde a instala??o. Ap?s o primeiro ano de controle os demais retornos tiveram periodicidade anual. A ocorr?ncia de complica??es ou falhas prot?ticas foi observada e registrada em ficha cl?nica espec?fica ao longo de 39 meses. Os padr?es de falhas observados foram enquadrados nas seguintes situa??es: ocorr?ncia de ?lceras traum?ticas depois de 2 meses de instala??o, aus?ncia de reten??o, fratura de nicho ou c?rie sob o nicho, fratura ou descolamento dos dentes artificiais, fratura do conector maior, fratura de grampo, fratura do apoio, suporte deficiente (necessidade de reembasamento da pr?tese) e fratura da pr?tese. Resultados: A ocorr?ncia de complica??es apresentou baixa frequ?ncia, sendo maior a partir do segundo ano de uso da pr?tese. Dentre as complica??es que mais aconteceram est? a perda de reten??o (31,57%). Falhas de maior gravidade e de dif?cil resolu??o como a fratura de elementos da estrutura met?lica da PPR tiveram baixa ocorr?ncia e foram representadas por apenas um caso de fratura do conector maior (5,3%). Conclus?o: Pr?teses parciais remov?veis de extremidade livre mandibulares opostas a pr?teses totais convencionais apresentam baixo ?ndice de complica??es ap?s 39 meses de uso quando submetidas a controles peri?dicos
27

Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitos /

Santos, Ciandrus Moraes de Freitas. January 2005 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Eduardo Passos Rocha / Banca: Alcides Gonini Júnior / Resumo: A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / Abstract: The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions. / Mestre
28

Avalia??o cl?nica longitudinal do periodonto de dentes pilares e n?o pilares de pr?teses parciais remov?veis

Amaral, Bruna Aguiar do 27 February 2007 (has links)
Made available in DSpace on 2014-12-17T15:31:01Z (GMT). No. of bitstreams: 1 BrunaAA.pdf: 501159 bytes, checksum: 30bc6bac9bef1fd1e36f669902ea0e7c (MD5) Previous issue date: 2007-02-27 / The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition / A literatura tem mostrado uma rela??o entre a periodontia e a pr?tese parcial remov?vel (PPR), observando-se destrui??es progressivas das estruturas de suporte. O prop?sito do presente trabalho ? avaliar clinicamente a condi??o periodontal em usu?rios de pr?tese parcial remov?vel (PPR), comparando os dentes pilares diretos, pilares indiretos e os dentes n?o envolvidos no desenho da pr?tese, antes da instala??o e ap?s 1 ano de uso. E ainda comparar os pilares diretos de PPR dento-suportada e dento-muco-suportada. Um total de 50 pacientes, 32 do sexo feminino e 18 do masculino, com idade m?dia de 45 anos participaram da pesquisa. Os pacientes foram examinados no momento da instala??o da pr?tese e ap?s 3, 6, 9 e 12 meses, por um ?nico examinador. Em cada exame foram verificados: a recess?o gengival (RG) profundidade de sondagem (PS), o ?ndice de placa (IP), o ?ndice gengival (IG), a quantidade de mucosa ceratinizada (MC), e a mobilidade dent?ria (MB), al?m da orienta??o de higiene oral, acompanhada de profilaxia e raspagem e alisamento corono - radicular (RACR) quando necess?ria. Para avaliar o comportamento das vari?veis dependentes (RG, PS, IP, MC) dos tr?s grupos ao longo do tempo, o teste de escolha foi a an?lise de vari?ncia de tend?ncia linear com o p?s teste de Tukey-Kramer, e para a vari?vel IG foi realizado o teste de Friedman. Para avaliar os desfechos com rela??o ao tipo de pr?tese no grupo pilar direto, foi feita an?lise a partir do intervalo de confian?a. Os resultados mostraram que o grupo controle foi o que apresentou menor comprometimento em todas as vari?veis estudadas. Com rela??o ao desenvolvimento dos grupos no decorrer do tempo, verificou-se que as m?dias da RG, PS, IG e MC aumentaram do exame inicial para 1 ano de uso, em todos os grupos, mas somente o IP mostrou aumento significativo. A mobilidade dent?ria foi pouco discriminat?ria por apresentar baixa preval?ncia. No que diz respeito ? diferen?a entre as pr?teses, a pr?tese dento-muco-suportada mostrou valores significativamente superiores de RG, IG e IP e significativamente inferiores MC em rela??o ? dento-suportada. Ao longo do tempo, os dois tipos de pr?tese n?o apresentaram diferen?as significativas do exame inicial para o final para as vari?veis: RG, PS, MC e IG, j? IP foi significativo somente na pr?tese dento-suportada. Os resultados obtidos mostraram que os dentes mais envolvidos no desenho da PPR apresentaram maior potencial de destrui??o periodontal, provavelmente por apresentarem maior ac?mulo de biofilme dent?rio. Elementos pilares adjacentes a extremidades livres apresentaram condi??o periodontal menos favor?vel do que os pilares adjacentes a espa?os intercalados, por?m o uso de PPR n?o agravou a condi??o inicial
29

Retenção de grampos cirucenferenciais associados a retentores intra-radiculares com encaixe era utilizados em overdentures parciais removíveis / Retention clips cirucenferenciais associated with CuAlZn with docking was used in removable partial overdentures

SOUZA, José Everaldo de Aquino 18 July 2008 (has links)
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1 dissertacao everaldo.pdf: 1049399 bytes, checksum: fe0d5a65718b57ccb2f6a6d2bf11cb9a (MD5) Previous issue date: 2008-07-18 / The overdentures can be defined as total or partial removable dentures that cover root or osseo integrated implants rehabilitating the whole dentition. The mechanical retention in the removable partial overdentures (RPOs) is obtained through the use of cast clasps and attachments. This biomechanical principle has a great importance, since is inwardly associated with long term behavior and clinical performance of prosthesis and consequently, with comfort and satisfaction of the patients. So, the aim of this study was to assess the retention of metallic framework with simple circumferential claps associated intraradicular retainer with attachment type ERA (Extra coronal Resilient Attachment, Sterngold Implamed, Attleboro, EUA) in function of the metals based cobalt-chromium alloy (Co-Cr), titanium commercially pure (Ti cp) and nickel-chromium with titanium alloy (Ni-Cr with Ti), of the retentive undercuts of 0,25mm and 0,75mm and in function of the time of use in each simulated period (initial, 6 months, 1, 2, 3, 4 e 5 years). Through of metallic matrices representing a partially edentulous mandibular right hemi-arch segment constituted by the crown of the first molar, root of the inferior canine and with the absent of the premolars, were made 60 metallic frameworks being obtained 03 groups of each metal and subgroups representative of the 0,25mm and 0,75mm retentive undercuts of the circumferential clasp (totalizing 10 samples in each subgroup). Acrylic denture bases were constructed on the denture space and on the canine root that anchored the attachments and these received retentive capsules in the gray color of the system. Previously the mechanic tests, radiographic exams of the Ti cp frameworks were realized with the aim of detecting possible casting defects that could avert the posterior use. Next, the samples were mechanically tested simulating the insertion and removal of the framework using the testing apparatus designed at the Ribeirão Preto School of Dentistry (Testing apparatus, São Paulo University, Ribeirão Preto, Brazil), representing 5 years of simulated used. To simulate the intraoral conditions and realize the tests, a gadget fulfilled with artificial saliva was adapted in the testing apparatus. The retentive force data were recorded and submitted linear regression analysis and analysis of variance (ANOVA) to gauge a presence or not of significant differences and applied the Tukey complementary test 5% to comparison of the differences between the groups and subgroups. The groups of Ni-Cr with Ti and Co-Cr samples obtained most retentive mean with significant differences to group of Ti cp samples that obtained least retentive mean in every periods of time analyzed. To groups Ni-Cr with Ti and Co-Cr samples there was not significant difference of retention between the times analyzed free-standing of retentive undercuts (p > 0,05). In the group Ti cp samples there was significant difference of retention between the times analyzed just to subgroup samples with 0,75mm undercuts (p < 0,05). The Ni-Cr with Ti and Co-Cr samples with 0,75mm undercuts presented the most retentive mean and the Co-Cr samples with 0,25mm undercuts presented retention mean intermediate between biomechanical design in every periods of time analyzed. The Ti cp samples with 0,25mm undercuts presented the least retentive mean until second year of the analyze and the Ti cp samples with 0,75mm undercuts presented the least retentive mean of third until fifth year of the analyse. The circumferential claps casting in Ti cp used in 0,75mm undercuts have potential risk of fractures, mainly after the 2o year of use / As overdentures (sobredentaduras) podem ser definidas como próteses removíveis totais ou parciais, que cobrem raízes ou implantes osseointegrados reabilitando toda a dentição. A retenção mecânica nas overdentures parciais removíveis (OPRs) é obtida por meio da utilização combinada de grampos fundidos e encaixes. Este princípio biomecânico é de grande importância, visto que está intimamente relacionado com o comportamento e o desempenho clínico em longo prazo das próteses e conseqüentemente, com o conforto e satisfação dos pacientes. Assim, o objetivo deste estudo foi avaliar a retenção de estruturas com grampos circunferenciais simples associadas a retentores intra-radiculares com encaixe do tipo ERA (Extra coronal Resilient Attachment, Sterngold Implamed, Attleboro, EUA) em função dos metais à base de cobalto-cromo (Co-Cr), titânio comercialmente puro (Ti cp) e níquel-cromo com titânio (Ni-Cr com Ti), dos contornos retentivos de 0,25mm e 0,75mm e em função do tempo de uso em cada período simulatório (inicial, 6 meses, 1, 2, 3, 4 e 5 anos). A partir de matrizes metálicas representativas de uma hemi-arcada inferior direita parcialmente desdentada com as presenças da coroa do primeiro molar, raiz do canino e com os pré-molares ausentes, foram confeccionadas 60 estruturas metálicas sendo obtidos 3 grupos de cada metal e subgrupos representativos dos contornos retentivos de 0,25mm e 0,75mm do grampo circunferencial (perfazendo 10 amostras por subgrupo). Foram confeccionadas bases protéticas sobre o espaço protético e raiz do canino que ancoraram os encaixes e estes receberam as cápsulas retentivas de cor cinza do sistema. Previamente aos ensaios mecânicos, exames radiográficos das estruturas em Ti cp foram realizados para detectar possíveis defeitos de fundição que pudessem inviabilizar o uso posterior. Em seguida, as amostras foram ensaiadas mecanicamente simulando movimentos de inserção e remoção da estrutura utilizando uma máquina de ensaios projetada na Faculdade de Odontologia de Ribeirão Preto (Máquina de Ensaios, Universidade de São Paulo, Ribeirão Preto, Brasil), representando o uso simulado de 5 anos. Para simular as condições intrabucais e realizar os ensaios, um dispositivo preenchido com saliva artificial foi adaptado ao simulador. Os dados de força retentiva foram registrados e submetidos à análise de regressão linear e à análise de variância (ANOVA) para aferir a presença ou não de diferenças estatisticamente significativas e aplicado o teste de Tukey à 5% de probabilidade para comparação das diferenças entre os grupos e subgrupos. As amostras dos grupos em Ni-Cr com Ti e Co-Cr obtiveram as maiores médias de retenção com diferenças estatisticamente significantes para as amostras do grupo em Ti cp que obtiveram as menores médias de retenção em todos os períodos de tempo analisados. Para os grupos das amostras em Ni-Cr com Ti e Co-Cr não houve diferença de retenção estatisticamente significante entre os tempos analisados independente dos contornos retentivos (p > 0,05). No grupo das amostras em Ti cp houve diferença de retenção estatisticamente significante entre os tempos analisados apenas para as amostras do subgrupo com contorno retentivo de 0,75mm (p < 0,05). As amostras em Ni-Cr com Ti e em Co-Cr com contorno retentivo de 0,75mm apresentaram as maiores médias de retenção e as amostras em Co-Cr com contorno retentivo de 0,25mm apresentaram retenções médias intermediárias entre os desenhos biomecânicos em todos os períodos de tempo analisados. As amostras em Ti cp com contorno retentivo de 0,25mm apresentaram as menores médias de retenção até o segundo ano de análise e as amostras em Ti cp com contorno retentivo de 0,75mm apresentaram as menores médias de retenção do terceiro ao quinto ano de análise. Os grampos circunferenciais fundidos em Ti cp utilizados em contornos retentivos de 0,75mm tem um risco potencial de fraturas, principalmente após o 2o ano de uso
30

"Análise comparativa pelo método dos elementos finitos bidimensional das tensões geradas nas estruturas de suporte de prótese parcial removível de extremidade livre inferior sobre rebordo residual ascendente distal e descendente distal"

Camargo, Renato Zanutto Bueno de 14 April 2005 (has links)
Nesta pesquisa, foi realizada uma análise comparativa, por meio do método dos elementos finitos bidimensional linear, das deformações e tensões geradas a partir da aplicação de uma carga de 100N, nas estruturas de suporte (fibromucosa,ligamento periodontal, osso cortical e osso esponjoso) de dois modelos que simulam um hemiarco mandibular associada a uma prótese parcial removível de extremidade livre dista inferiorl, quando da variação da inclinação do rebordo residual no plano sagital. O modelo A (MA) foi desenhado com um rebordo ascendente distal com 15 graus de inclinação e o modelo B (MB) com um rebordo descendente distal com 15 graus negativos, ambos em relação ao plano oclusal. Nos dois modelos aplicou-se uma carga primeiramente na cúspide médio-vestibular do primeiro molar inferior artificial (C1) e depois na cúspide vestibular do segundo pré-molar inferior (C2), por meio do programa I-deas (software de elementos finitos) onde foram feitas as análises de deformações e tensões e processamento das imagens. Fez-se então uma análise comparativa dos carregamentos (C1 e C2) em cada modelo individualmente e entre os dois modelos(MA e MB). Os resultados permitiram concluir que: 1) A inclinação do rebordo residual no plano sagital influenciou na distribuição e na intensidade das tensões das estruturas de suporte; 2) No osso cortical as tensões foram mais localizadas e de maior intensidade que no osso esponjoso; 3) A diferença de deformação entre fibromucosa e ligamento periodontal foi maior quando a carga foi aplicada no primeiro molar, de ambos os modelos, sendo a mais expressiva no rebordo ascendente distal; 4) As tensões de compressão foram maiores em intensidade e melhor distribuídas no osso esponjoso e no osso cortical, quando comparadas as tensões de tração; 5) O rebordo ascendente distal se mostrou mais favorável à distribuição das tensões nas estruturas de suporte quando comparado ao rebordo descendente distal; 6) Nos dois modelos a aplicação da carga no primeiro molar gerou um maior torque sobre o dente suporte para a distal do que quando aplicado no segundo pré-molar, principalmente no rebordo descendente distal; 7) As estruturas de suporte do rebordo residual foram mais solicitadas em C1 que em C2, em ambos os modelos, principalmente no rebordo ascendente distal; 8) No dente suporte as tensões nas estruturas de suporte foram mais axiais quando o carregamento ocorreu no segundo pré-molar inferior, em ambos os modelos. / In this study, a two-dimensional finite element comparative analysis of the stress distribution and of displacement in the supporting structures – oral mucosa,periodontal ligament, compact and cancellous bone – was carried out for a distal extension base removable partial denture (RPD), modeled on two mandibular dental archs with different types of residual ridge when aplaying loads of 100N. The A model (MA) was developed to include a distal ascending alveolar ridge with a 15-degrees positive inclination, while the B model (MB) was prepared with a distal descending alveolar ridge with a 15-degrees negative inclination. Both models had a load applied inicially on the lower first molar median cusp (C1) and then on the lower second premolar buccal cusp (C2). Using the FEA software (I-DEAS, USA) for the stress distribution and displacement analysis of the generated images. A comparative analysis was them performed on the C1 and C2 loads for which and both models (MA and MB).The results showed that: 1 – The alveolar ridge inclination showed some degree of on the stress distribution and intensity generated by the RPD; 2 –The compact bone showed greater stress concentration and intensity than the cancellous bone; 3 – The ratio between oral mucosa and periodontal ligament displacement showed greater values when load was applied on the lower first molar for both models. The ratio was higher for the distal ascending alveolar ridge; 4- The compressive stress showed greater intensity and better range of distribution than the tensile stress for both the compact and cancellous bone; 5 – The distal ascending residual ridge had a more favourable stress distribution than distal descending conterpart ; 6 – The load applied on the lower first molar produced more distal torquing on the supporting tooth than that on the lower second premolar ,specially on the distal descending residual ridge; 7 – the load applied on the lower firt molar generated greater amount of stress on the residual ridge supporting structures for both models, but specially for the distal ascending residual ridge; 8 – The load applied on the lower second premolar produced more vertical forces on the supporting structures of the tooth for both models.

Page generated in 0.4713 seconds