• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 20
  • 20
  • 16
  • 12
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta /

Alencar Júnior, Emmanuel Arraes de. January 2002 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Mânio de Carvalho Tibúrcio / Resumo: O objetivo desta pesquisa foi avaliar a influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta, considerando as superfícies de topo e base dos corpos-de-prova. Foram utilizadas duas marcas comerciais de resina composta, Z250 de partículas pequenas e uma resina de micropartícula, A110, ambas da 3M do Brasil Ltda. O aparelho de ativação da resina composta foi K&M 220- R, cuja intensidade de luz possui um pulso que variava após os 5 primeiros segundos assim alcançando sua intensidade máxima que foi medida em 720 mW/cm2. Para a determinação da intensidade de luz emitida pelo aparelho fotoativador, utilizou-se um radiômetro (Medidor de irradiância 150- CMC , São Carlos - SP). Corpos-de-prova foram confeccionados utilizado-se matrizes metálicas que possuíam um orifício central de 4mm de diâmetro por 2mm de espessura. As resinas foram inseridas no orifício da matriz metálica, em um único incremento, por meio de uma espátula metálica e sobre elas foi sobreposta uma tira matriz transparente de poliéster e, após isto, um peso de 1 Kg foi posto em cima da tira para que houvesse uma melhor condensação da resina composta evitando a presença de bolhas de ar, no interior do corpo-de-prova. A fonte de luz halógena foi fixada em uma mesa de maneira que a saída da ponta de luz ficasse paralela à superfície do corpo-de-prova. Para provocar o distanciamento da fonte de luz, anéis metálicos confeccionados em latão, com espessuras que variavam de 2mm, 4mm e 8mm foram utilizados, os quais, após posicionados, eram removidos para não interferiem no dispersamento da luz. As distâncias imprimidas a fonte de luz na superfície da resina foram de 0mm(tocando a superfície), 2mm, 4mm e 8mm. Para cada uma destas distâncias, a intensidade de luz foi medida. Esta variou de intensidade de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this research was to evaluate the influence of the light tip distance in the superficial microhardness of the composite resin, considering the surfaces of top and base of the samples. Two commercial composite resin marks had been used, Z250 of small particles e a microparticle resin, A110, both of 3m of Brazil Ltda. The device of activation of the composite resin was K&M 220- R, whose intensity of light possess a pulse that varied the 5 first seconds after thus reaching its maximum intensity that was measured in 720 mW/cm2. For the determination of the intensity of light emitted for the fotoativador device, a radiometer (Measuring of irradiance 150- CMC was used, Is Carlos. SP). The samples had been confectioned used first metallic that had a central orifice of 4mm of diameter for 2mm of thickness. The resins had been inserted in the orifice of the metallic array, in an only increment, by means of a metallic spatula and on them a transparent first polyester strap was overlapped and, after this, one weight of 1 kg was rank in top of the strap so that it had one better condensation of the composite resin preventing the presence of air bubbles, in the inward of the body-of-test. The source of light was fixed in a table thus the output of the light tip was parallel to the surface of the body-of-test. To provoke distance from the light source, confectioned metallic rings in brass, with thickness that varied of 2mm, 4mm and 8mm had been used, which, after located, was removed to avoid concentration of light. The printed pitches the source of light in the surface of the resin had been of 0mm(on the surface), 2mm, 4mm and 8mm. For each one of these pitches, the light intensity was measured. This varied of intensity of 720 mW/cm2 for the tip touching the surface of the body-of-test, 650 mW/cm2 for in the distance of 2mm, 600 mW/cm2... (Complete abstract, click electronic address below). / Mestre
12

Avaliação da resistência ao desgaste de uma resina composta odontológica nanoparticulada empregando diferentes tempos de fotopolimerização /

Souza, Celso Naves de. January 2009 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Edson Cocchieri Botelho / Banca: Carlos Roberto Grandini / Banca: Sandra Giacomin Schneider / Banca: Sergio Scheneider / Resumo: Este trabalho tem como objetivo avaliar a influência dos tempos de fotopolimerização nas resinas odontológicas, onde quatro resinas compostas foram utilizadas, sendo três micro híbridas e uma nanoparticulada. Esses compósitos foram submetidos ao desgaste abrasivo de esfera rotativa pelo método de ball cratering. Para tal ação foi projetado e construído um dispositivo de desgaste por micro abrasão de esfera rotativa livre de três corpos. Os corpos de prova foram confeccionados e embutidos em uma matriz de alumínio, com uma profundidade de 2mm. Usam-se o aparelho LED RADII, com os tempos de exposição de 20, 30 e 40 segundos e uma esfera com 15 mm de diâmetro de aço temperada, retificada e revenida. A lama abrasiva utilizada nesse estudo foi uma solução composta por 20% de talco (USP/200) e 80% de soro fisiológico, na quantidade de 3 gotas por segundo. Para comprovação dos resultados obtidos, utilizaram-se os testes de: Espectroscopia por Dispersão de Energia (EDS), Infravermelho por Transformada de Fourier (FT-IR), Análise Termogravimétrica (TGA), micro dureza Vickers, ensaio de desgaste de micro abrasão por esfera rotativa pelo método de ball cratering e a análise da superfície desgastada por Microscopia Eletrônica de Varredura (MEV). Esta análise foi realizada para verificar o real mecanismo de desgaste ocorrido. Os resultados obtidos comprovam que o tempo recomendado pelos fabricantes, tem a capacidade suficiente de fotopolimerizar toda a matriz orgânica, comprovaram também que a resina nanoparticulada obteve em todos os ensaios os melhores resultados em relação às resinas híbridas, e que a cultura do acréscimo de até 20s além do recomendado não tem influência direta em relação ao desgaste abrasivo. / Abstract: This work has as an objective to evaluate the influence of photopolymerization in odontological resins, where composed four resins were used, being three of them micro hybrid and one nanoparticulated. These composites were submitted to abrasive wear and tear of rotative sphere by the method ball cratering. For such action a device of micro abrasion of rotative sphere was designed and built free of three bodies. The bodies of proof were produced and put in a matrix of aluminum with a depth of 2mm. The device used was a LED RADII, with exposition time of 20, 30 and 40 seconds and a sphere of 15mm diameter made of tempered steel, rectified and soften, the abrasive lama used in this study was a solution composed by 20% of powder (USP/200) and 80% of physiological serum released at 3 drops per second. For verification of the results obtained the tests of Energy Dispersion Spectrograph (EDS) was used, transformed Infra red of Fourier (FT-IR), Thermogravimetric Analysis (TGA) Vickers micro hardness, wear and tear of micro abrasion by rotative sphere by the method ball cratering and the analysis of worn superficies by Sweeping Electronic Microscopy (SEM). This analysis was carried out to verify the real mechanism of the worn occurred. The results obtained prove that the time recommended by the manufacturer has enough capacity to photopolymerized all the organic matrix, it also proved that the resin nanoparticulated obtained in all the essays the best results in what concerns to the hybrid resins. And the culture of the addition of 20 seconds besides what is recommended has no direct influence in relation to the abrasive wear and tear. / Doutor
13

Resistência adesiva de reparos em resina composta : tratamento da superfície com ponta diamantada, jato de óxido de alumínio e laser de Er:YAG /

Gois, Ana Maria de. January 2004 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Vanderlei Salvador Bagnato / Banca: José Eduardo Pelizon Pelino / Resumo: Este estudo avaliou a resistência adesiva de microtração em reparos de resinas compostas, novas e envelhecidas, após tratamento da superfície usando irradiação a laser de Er: YAG, ponta diamantada e abrasão a ar. 36 blocos de resina composta híbrida Z100 (3M) com 5mm de comprimento e 6 mm de lado foram confeccionados com auxílio de uma matriz. Metade desses blocos foram reparados após 24 horas, e a outra metade foi reparada após envelhecimento artificial com luz ultravioleta. Cada grupo foi subdividido em 6 subgrupos e as superfícies experimentais foram submetidas a diferentes tratamentos: (G1) desgaste com ponta diamantada; (G2) jateamento com partículas de óxido de alumínio de 60 mm; (G3) ablação com laser de Er: YAG a um nível de energia de 100mJ; (G4) ablação com laser de Er:YAG a um nível de energia de 200mJ; (G5) ablação a laser de Er:YAG a um nível de energia de 300mJ; (G6) controle- ausência de tratamento de superfície. Após tratamento da superfície, o agente adesivo (Single Bond 3M) foi aplicado e os blocos foram reparados com a resina composta Point4 (KERR). Reparados, os blocos foram seccionados em espécimes de 1.0 mm2. A resistência adesiva de microtração foi medida em uma máquina de teste universal MTS. No grupo que foi reparado 24 horas após, não houve diferença estatisticamente significante na resistência adesiva interfacial entre os subgrupos. No grupo que foi envelhecido, os subgrupos G1 e G3 tiveram as maiores médias de resistência adesiva de reparo. Significantemente, os menores valores foram achados para os subgrupos G2 e G6. As médias da resistência adesiva de reparo foram estatisticamente similares para G3, G4 e G5. O exame em SEM indicou que a fratura adesiva foi o tipo predominante de falha. Os resultados desse estudo indicam que os maiores valores de resistência adesiva foram achados para o desgaste da superfície com... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: This study assessed the microtensile bond strengths of composite repairs, new and aged, after surface treatments, using Er:YAG laser irradiation, diamond bur and air abrasion. 36 blocks of hybrid composite resin Z100 (3M) with 5.0 mm length and 6.0 mm of side were made in mold. Half of these blocks were repaired after 24 hr and the other half was aged in an artificial aging chamber with exposure to a total ultraviolet irradiation. Each group was then divided into six subgroups and the experimental surface was exposed to a different treatment: (G1) grinding with diamond burs; (G2) air-abraded with 60mm aluminum oxide particles; (G3) ablation with an Er: YAG laser under the energy level of 100 mJ; (G4) ablation with an Er: YAG laser under the energy level of 200 mJ; (G5) ablation with an Er: YAG laser under the energy level of 300 mJ; (G6) controle - with no surface treatment. After the resin treatment on the surface, the bonding agent (Single bond, 3M) was applied and the blocks were repaired with the resin Point4 (Kerr) composite. Repaired, the blocks were sectioned into specimens (stick) of 1.0 mm2. Microtensile bond strength was measured in a universal testing machine MTS. The group repaired after 24 hours did not present statistically significant differences on interfacial bond strengths between the subgroups. On the aged group, the subgroups G1 and G3 presented the highest mean of repairing bond strenght. Significant lower values were found for subgroups G2 and G6 .The mean of repairing bond strenght was statistically similar for G3, G4 and G5. SEM examination indicated that adhesive failure was the predominant mode of failure. The results of this study indicate that the highest bond values were achieved by grinding the surface with diamond burs and ablating the surface with an Er: YAG laser under the energy level of 100mJ... (Complete abstract, click electronic address below). / Mestre
14

Avaliação da dureza e do grau de conversão de uma resina composta em função do pré-tratamento térmico e da fonte de luz fotopolimerizadora /

Saade, Esther Gomes. January 2009 (has links)
Resumo: O objetivo desse trabalho foi investigar a influência do pré-aquecimento da resina composta anterior à fotopolimerização, sobre suas propriedades físicas e mecânicas como: o grau de conversão e dureza. As amostras foram fotopolimerizadas com uma unidade de luz halógena de quartzo-tungstênio (QTH) e uma unidade diodos emissores de luz azul (LED) por 40 s. Os compules de resina composta híbrida foram pré-aquecidos no dispositivo denominado Calset. A conversão dos monômeros a polímeros foi determinada através do FTIR-ATR. A propriedade de dureza foi avaliada no Microdurômetro MMT-3 Microhardness Tester equipado com o diamante Vickers. Para o teste de dureza Vickers cinco amostras para cada grupo (4 mm de diâmetro e 2 mm de espessura) foram confeccionadas com a resina composta pré-aquecida nas seguintes temperaturas: 37ºC, 54ºC e 60ºC (n=5). As amostras foram submetidas ao teste de dureza Vickers imediatamente após a sua confecção. Foram efetuadas 4 medidas no topo e 4 na base de cada amostra. De acordo com a interação entre as duas unidades de luz e o aumento de temperatura da resina composta, os resultados indicam que somente a unidade de luz influenciou nas médias dos valores de dureza Vickers. A unidade LED apresentou valores de dureza mais homogêneos entre o topo e a base da resina composta, evidenciando uma polimerização mais uniforme. O preaquecimento da resina composta não apresentou diferenças estatisticamente significativas nos valores de dureza. Para a avaliação do grau de conversão foram confeccionadas 5 amostras (4 mm de diâmetro e 2 mm de espessura) para cada grupo, utilizando a unidade QTH e LED, e a resina composta nas seguintes temperaturas: 25ºC (temperatura ambiente), 37ºC, 54ºC e 60ºC (n=40). Após a confecção as amostras foram preparadas para a análise do grau de conversão através do FTIR-ATR. Segundo os resultados conclui-se que não houve diferenças estatisticamente significativas. / Abstract: The aim of this study was to evaluate the physics and mechanical properties of the pre-heating of the composite resin photo-activated. The samples were photo-activated with a light-curing unit QTH and LED for 40 s. The compules of hybrid composite resin for anterior restorations were pre-heated in the device called "Calset". The monomer conversion was analyzed using the FTIR-ATR. The hardness property was evaluated with microdurometer MMT-3 equipped with diamond Vickers. Five samples were made for each group (4 mm in diameter and 2 mm in thickness) which the composite resin were pre-heated at temperatures three: 37°, 54° and 60°C. Immediately were submitted to hardness test, which the top and bottom surfaces of the samples took, place an impression for quadrant. According to the interaction between both light-curing units and the increase of the temperature of composite resin, the results showed that only lightcuring unit influenced the hardness average values. The LED light showed a cure homogeneous across the surface of the composite resin and good values of Vickers hardness. The pre-heating of composite resins prior to cure did not show statistically significant differences in the hardness values. For to evaluate the degree of conversion, five samples were made (4 mm in diameter and 2 mm in thickness) for each group using light-curing unit QTH and LED, with the composite resin pre-heated at temperatures of 25ºC (room temperature), 37ºC, 54ºC and 60ºC and analyzed in the spectrophotometer. No significant differences were found in the degree of conversion of the composite resin cured with QTH or LED and to different pre-heating of the composite resin. In this study, any evidence was found that type of light-curing unit used and pre-heating of composite resin could improve the degree of conversion. / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Darlon Martins Lima / Banca: José Roberto Cury Saad / Mestre
15

Análise "in vitro" da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras /

Calixto, Abraham Lincoln. January 2003 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Paulo Sergio Quagliato / Banca: João Carlos Gomes / Resumo: O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below) / Doutor
16

Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura /

Mazur, Rui Fernando. January 2003 (has links)
Orientador: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Welingtom Dinelli / Banca: Rodrigo Nunes Rached / Banca: Paulo Sérgio Quagliatto / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below). / Doutor
17

Preparação e caracterização de resina epóxi transparente dopada com nanoestruturas semicondutoras de CdS /

Silveira, João Borges da. January 2009 (has links)
Orientador: Victor Ciro Solano Reynoso / Banca: Keizo Yukimitu / Banca: Raul Fernando Cuevas Rojas / Resumo: O presente trabalho visou a produção e o estudo das propriedades físicas de amostras de resina epóxi transparente dopadas com diferentes concentrações de nanocristais de sulfeto de cádmio (CdS). As técnicas de difração de raios-X, espectroscopia no infravermelho, espectroscopia Raman e calorimetria diferencial de varredura (DSC) foram utilizadas para estudar as propriedades estruturais. Espectroscopias de refletância e de transmitância foram utilizadas para obter a dispersão do índice de refração e do coeficiente de extinção na região do UV-Vis para amostras dopadas com diferentes concentrações de CdS. A técnica do ângulo de Brewster foi também utilizada para determinar o índice de refração das diferentes amostras. Os valores dos índices de refração obtidos através das medidas de refletância e de transmitância na região do UV-Vis e da técnica do ângulo de Brewster foram comparados e os resultados mostraram que a técnica do ângulo de Brewster além de apresentar valores que conferem com a literatura apresentou valores com alta precisão. Foram realizadas medidas de birrefringência opticamente. Foram obtidos resultados da birrefringência fotoinduzida por um fóton para diferentes concentrações de CdS por amostra e para diferentes intensidades da luz de excitação. Os resultados foram quantificados utilizando alguns dos principais modelos teóricos, onde foi observado que a resina epóxi pura apresenta birrefringência fotoinduzida e a adição do CdS contribui para o aumento da birrefringência. / Abstract: The present work sought production and study of the physical properties of samples of transparent epoxy resin doped with different concentrations of structures of cadmium sulfide (CdS) nanocrystals. X-ray diffraction, infrared spectroscopy, Raman spectroscopy e differential scanning calorimetry techniques were used to study their structural properties. Reflectance and transmittance spectroscopy were used to obtain of the refraction index and of the extinction coefficients dispersion in the UVVis region for doped samples with different concentrations of CdS. The Brewster angle technique also was used to determine the refraction index of the different samples. The refraction index values obtained using the reflectance and transmittance measurement in the UV-Vis region and Brewster angle technique were compared and the results showed that the Brewster angle technique besides presents values that check with the literature, presented values with high precision. Measurements of optically induced birefringence were accomplished. Were obtained results of the photo induced birefringence by a photon for different concentrations of CdS for sample and for different intensities of the excitement light. The results were quantified using some of the principal theoretical models, where was observed that the pure epoxy resin presents photo induced birefringence and the addition of the CdS contributes to the increase of the birefringence. / Mestre
18

Propriedades do sistema epoxídico DGEBA/TETA modificado com fibras naturais de bagaço de cana-de-açucar /

Barbosa, Fernando Montanare. January 2010 (has links)
Orientador: Newton Luiz Dias Filho / Banca: Devaney Ribeiro do Carmo / Banca: Patrícia Alexandre Antunes / Resumo: Esse trabalho tem como objetivo avaliar as propriedades mecânicas e térmicas de compósitos reforçados com bagaço de cana-de-açúcar. Para a preparação das amostras estudadas o bagaço da cana-de-açúcar foi desmedulado e triturado até atingir um comprimento médio entre 106 e 212 μm. Estas fibras foram tratadas quimicamente com uma solução hidróxido de sódio (NaOH) 10% para, posteriormente, ser adicionado ao epóxi DGEBA/TETA em concentrações de 1, 3, 5, 7,5 e 10% em massa. Foi obtido um aumento de 26,12% no limite de resistência à tração (LRT) do compósito com a adição de 3% de fibras, permanecendo constante em porcentagens superiores. Do mesmo modo, o módulo de elasticidade (E) teve um aumento de 12,5%, e o Limite de Resistência à propagação de trincas (K1C) teve um pequeno decréscimo em relação ao polímero não modificado com a adição de 3% de fibra de cana-de-açúcar (5,6%), permanecendo-se constante em porcentagens superiores. Além disso, os dados obtidos mostram que as propriedades térmicas não foram alteradas com a adição de fibras ao sistema DGEBA/TETA. / Abstract: This work has as objective to evaluate the mechanical and thermal properties of composites reinforced with sugarcane bagasse. For the studied samples preparation the sugarcane bagasse was triturated until being an average lengh between 106 and 212 μm. This fibers were going treated chemically with a solution NaOH 10%, for, afterwards, be added to epoxy DGEBA/TETA in concentrations of 1, 3, 5, 7.5, 10% in mass. An increase of 26,12% in Tensile strength (LRT) with addition of 3% of fibers was obtained, remaining constant to the superior percentages. In the same way, the Modulus of elasticity (E) had an increase of 12,5% and Fracture toughness (K1C) had a small decrease regarding the polymeric not modified (5,6%) with the addition of 3% of sugarcane fiber, remaining constant to the superior percentages. Moreover, the obtained values show that the thermal properties were not changed with the fiber addition in the sistem DGEBA/TETA. / Mestre
19

Influência da fonte de luz fotoativadora nas propriedades ópticas de resína composta, em função da cor, espessura e tempo de armazenamento /

Queiroz, Renato Souza. January 2010 (has links)
Orientador: Sizenando de Toledo Porto Neto / Banca: Alberto Magno Gonçalvez / Banca: Sicknan Soares da Rocha / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: Esse estudo se propõe a avaliar as propriedades ópticas (Fluorescência e Absorbância) da resina composta fotoativada (4 SEASONS®) utilizando aparelho fotopolimerizador convencional (luz Halógena Ulttralux - DabiAtlant), e aparelho emissor de Diodo (Radii - SDI e Ultralume Led 5- Ultradent), em função da fonte de luz foto-ativadora, cor, espessura e tempo de armazenamento em saliva artificial. Foram confeccionadas 5 amostras (10,0x1,0 mm) para cada grupo experimental. Para a realização do teste de Absorbância foi utilizado aparelho espectrofotômetro de luz visível (Diode Array Spectrophotometer, HP - Serial Number: 8452-A). Para a obtenção dos valores de fluorescência emitida pelas amostras, foi utilizado espectrofotômetro (SPEX TRIAX FLUOROLOG 3, Jobin Yvon - Serial Number: 0135B-3-99). Os resultados foram julgados estatisticamente conforme a interação entre os fatores de avaliação nos distintos trabalhos. Pode-se concluir que a fonte de luz fotoativadora influenciou apenas a emissão fluorescente da resina de cor TC, não tendo efeito negativo na absorbância; o aumento na espessura da amostra acarretou uma diminuição na emissão fluorescente e na absorbância de todas as cores da resina, independente da fonte de luz; e as diferentes cores da resina exibiram diferentes emissões fluorescentes e absorbância... / Abstract: The arm of this study is to evaluate optical properties (fluorescence and Absorbance) of a composite resin (4 SEASONS®) using light curing units (LCUs)-(QTH - Ulttralux - DabiAtlant and LEDs Radii - SDI and Ultralume Led 5- Ultradent) in function of LCUs, shade, thickness and storage times. 5 samples were prepared for each experimental group. To perform the Absorbance test, was used of UV-Vis spectrophotometer (Diode Array Spectrophotometer, HP - Serial Number: 8452-A). To obtain the fluorescence emission by samples, we used a spectrophotometer (SPEX TRIAX FLUOROLOG 3, Jobin Yvon - Serial Number: 0135B-3-99). The results were deemed statistically as the interaction between the evaluation factors in the different works. It can be concluded that the LCUs only influenced the fluorescent emission of resin color TC, having no negative effect on the absorbance; the increase in thickness of the sample decrease the fluorescent emission and absorbance for colors of the resin, independent of the LCUs; different colors of resin exhibited different fluorescent emission and absorbance. / Doutor
20

Nanocompósitos baseados no sistema epoxídico DEGBA/DETA modificado com uma resina epoxídica de silsesquioxano /

Rangel, Sibeli Amália. January 2006 (has links)
Orientador: Newton Luiz Dias Filho / Banca: Devaney Ribeiro do Carmo / Banca: Wagner Luiz Polito / Resumo: Polímeros epoxídicos são um dos mais importantes tipos de polímeros termorrígidos, extensivamente usados como adesivos e estruturas. Em reações epoxídicas são convertidos em um sistema termorrígido pela ação de agentes de cura. Tais reações químicas provocam uma mudança no estado físico do material, partindo de um líquido viscoso para um gel e se transformando em um material vitrificado. Os termorrígidos apresentam excelentes propriedades, tais como: alta tensão de ruptura e módulo de Young, fácil processamento, resistência térmica e química, e estabilidade dimensional. Entretanto, são quebradiços e possuem baixa resistência a propagação de trincas. Para superar estes inconvenientes, muitos tipos de compósitos de polímero com reforço foram desenvolvidos, em que as resinas epoxídicas são reforçadas com agentes modificadores, tais como enchimentos, oligômeros poliédricos de silsesquioxanos, dendrímeros, etc. Oligômeros poliédricos de silsesquioxanos (POSS), (RSiO1.5)n com n = 4, 6, 8, 10..., são nanoplataformas organo-funcionalizadas com 1 a 8 grupos reativos ou não reativos (R) ligados aos oito vértices possíveis do silsesquioxano cúbico. POSS octaédrico (n = 8) são os membros mais importantes desta família. No POSS, o núcleo cúbico de silicato é "uma partícula rígida" com 0,53 nm de diâmetro e um raio esférico de 1-3 nm, incluindo unidades orgânicas periféricas. Neste trabalho, um oligômero poliédrico de silsesquioxano contendo oito grupos epoxídicos por molécula (OG) foi incorporado ao sistema epoxídica DGEBA/DETA, como objetivo de avaliar a influência de um modificador reativo suas propriedades mecânicas e térmicas. Por meio de ensaios mecânicos foi observado um decréscimo de 30-50% na resistência à fratura (K1C)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Epoxy resins are one of the most important kind of thermosetting polymers, extensively used for adhesives and structural applications. On cure, linear epoxy resins are undergoes in a thermoset system for the action of cure agents. Such chemical reactions cause a change into the physical state, from a viscous liquid to a gel and eventually to a vitrified material. They show various desirable properties such as high tensile strength and modulus, easy processing, good thermal and chemical resistance and dimensional stability, but they are brittle and have poor resistance to crack propagation. To overcome these drawbacks, many types of polymer-filler composites have been developed, in which the epoxy resins are reinforced with modifying agents, such as fillers, polyhedral oligosilsesquioxanes, dendrimers, etc. Polyhedral oligomeric silsesquioxanes (POSS), (RSiO1.5)n with n = 4, 6, 8, 10 ...., are organofunctional nanoplatforms with 1 to 8 reactive or nonreactive groups (R) connected to the eight possible vertexes of cubic silsesquioxanes. POSS Octahedral (n = 8) are the most important members of this family. In the POSS, the cubic core silica is a "hard particle" rigid with 0.53 nm diameter and a spherical radius of 1-3 nm including peripheral organic units. In this work, a polyhedral oligomeric silsesquioxanes containing eight epoxy groups per molecule (OG) was incorporated to an epoxy system of DGEBA/DETA thermosetting polymers in order to investigate the influence of a reactive modifier over the their mechanical and thermal properties. Through the mechanical tests an decrease of about 30-50% was observed in the fracture toughness (K1C) without or with a very soft decreasing in the module of Young (E)... (Complete abstract, click electronic address below) / Mestre

Page generated in 0.4414 seconds