• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Influência da imersão em desinfetante a base de ácido peracético sobre as propriedades de um compósito odontológico de uso indireto

Fracaro, Gisele Baggio January 2005 (has links)
O objetivo deste trabalho foi avaliar a influência da imersão no desinfetante a base de ácido peracético 0,2% (STERILIFE, Lifemed Produtos Médicos Comércio Ltda, São Paulo, SP) sobre as propriedades de resistência flexural, sorção e solubilidade do compósito odontológico BelleGlass HP (Kerr, Orange, USA). Para cada ensaio foram confeccionados dez corpos de prova do compósito, utilizando-se as matrizes determinadas pela especificação no 4049 da International Organization for Standardization (ISO), sendo cinco submetidos a três imersões no desinfetante durante 10 minutos, intercaladas por 10 minutos em água destilada estéril e os outros cinco serviram como grupo controle. Para o ensaio de resistência flexural, após os corpos de prova ficarem imersos em água a 37° C, por 24 horas, foram levados à Máquina de Ensaio Universal DL 2000 (EMIC, São José dos Pinhais, Paraná, Brasil). A norma ISO n0 4049 exige uma resistência flexural mínima de 100 MPa. Para os ensaios de sorção e solubilidade os corpos de prova foram submetidos a ciclos a 37 C em um dessecador por 22 horas e, 2 horas em um segundo dessecador, a 23C, até a obtenção de uma massa constante (m1). Após 7 dias em banho de água a 37 C, procedeu-se à avaliação da massa do corpo de prova hidratado (m2). Posteriormente as amostras retornaram para o primeiro dessecador e todo o ciclo foi repetido até encontrar-se a terceira massa (m3) recondicionada. A norma ISO n0 4049 exige valores menores ou iguais a 40 g/mm3 e 7,5g/mm3 para a aprovação, em relação à sorção e solubilidade. Os resultados deste trabalho mostraram que as propriedades de resistência flexural, sorção e solubilidade do compósito BelleGlass HP de todos os corpos de prova dos grupos experimental e controle atenderam às exigências da especificação. Portanto pode se prever que o procedimento da imersão neste desinfetante não trará prejuízo às restaurações indiretas do compósito considerando as propriedades avaliadas.
102

Avaliação de LEDs de alta intensidade quanto à eficiência de polimerização de resina composta e variação de temperatura na dentina bovina

Mollica, Fernanda Brandão [UNESP] 29 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-29Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 mollica_fb_me_sjc.pdf: 859430 bytes, checksum: 9995882b109a407d775d587ef3cb2f1c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo avaliar a eficiência de polimerização de uma resina composta (RC) e a variação de temperatura na dentina bovina, empregando aparelhos de Diodo Emissor de Luz (LED) de alta intensidade em comparação a um aparelho de Quartzo-Halogênio-Tungstênio (QTH). Os aparelhos utilizados foram: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) e LED Radii (SDI, 1400 mW/cm2) e a RC, a Esthet X (Dentsply). Para o teste de microdureza Vickers, foram confeccionados 84 corpos-de-prova (2 mm x 5 mm) em matriz de teflon bipartida, variando-se o tempo de exposição em 10, 20 e 40 s, sendo que o aparelho XL 3000 foi utilizado para o grupo controle apenas pelo tempo de 40 s. Após 24 h, realizou-se o teste de microdureza no topo e na base dos corpos-de-prova com carga de 50 g e duração de 15 s. Para a medida da variação de temperatura ocasionada pelos aparelhos, foram utilizadas 45 fatias de dentina bovina de 0,7 mm de espessura e termopar tipo T conectado a um sistema de aquisição de dados ADS 2000 IP (Lynx Tecnologia). As fatias foram divididas em três grupos, sendo a variação de temperatura medida em três etapas: 1) durante a fotopolimerização do adesivo (10 s); 2) durante a fotopolimerização da RC (40 s) e 3) após 24 h (40 s). Os valores de microdureza do topo e da base e os dados de temperatura foram submetidos ao teste ANOVA de medidas repetidas e aos testes de Tukey e Dunnet (p=5%). Os resultados revelaram diferença estatística significante de microdureza no topo e na base quando se utilizaram ambos os LEDs por 10 s em relação ao uso do XL 3000 por 40 s, não havendo diferenças estatísticas entre os grupos com os tempos de 20 s e 40 s. A utilização do LED Radii pelos tempos de 10 e 20 s não foi suficiente... / The aim of this study was to evaluate the efficiency of polymerization of a resin composite and the temperature variation in bovine dentine, using two curing units of Light Emitting Diode (LED) of high intensity in comparison to a Quartz-Halogen-Tungsten device (QTH). The light curing units used were: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) and LED Radii (SDI, 1400 mW/cm2) and the resin composite, Esthet X (Dentsply). For the test of Vickers microhardness, 84 specimens (2 mm X 5 mm) were prepared in bipartite matrix of teflon, varying the time of exposition in 10, 20 and 40 s. The curing unit XL 3000 was used for the control group for 40 s. After 24 h, the microhardness test was made on the top and base of the specimens with 50 g of load and 15 s of duration. For the temperature variation measurement caused by the different curing units, 45 slices of bovine dentine of 0.7 mm thickness and a thermocouple type T hardwired to a system of data acquisition ADS 2000 IP (Lynx Technology) were used. The slices were divided in three groups and the temperature variation was measured in three stages: 1) during the adhesive photopolymerization (10 s); 2) during resin composite photopolymerization (40 s) and 3) after 24 h (40 s). The values of microhardness of the top and the base and the data of temperature variation were submitted to ANOVA of repeated measures test and to the tests of Tukey and Dunnet (p=5%). The results showed statistical significant difference of microhardness for the top and base values when both LEDs were used for 10 s in relation to the use of XL 3000 for 40 s, but no statistical differences were found between the groups when the exposition time was 20 s and 40 s. The use of LED Radii for 10 s and 20 s was not enough to equal statistically ... (Complete abstract, click electronic access below)
103

Análise comparativa da transmitância de diferentes tipos de resina composta pelo método de espectrofotometria de luz visível

Queiroz, Renato Souza [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T19:10:18Z : No. of bitstreams: 1 queiroz_rs_me_arafo.pdf: 1256542 bytes, checksum: fc1faa7ab6e3827911b6c0203d2355cf (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi avaliada comparativamente, pelo método de espectrofotometria de luz visível, a transmitância de 7 diferentes resinas compostas: G1- Charisma A2; G2-Filtek Supreme A2E; G3- Filtek Supreme A2B; G4- Filtek Supreme YT; G5- Esthet-X A2; G6- Esthet-X YE; G7- Durafill A2, e G8- Z-100 A2. Foram confeccionados 10 corpos de prova para cada grupo experimental com 10 mm de diâmetro e 2 mm de espessura. As amostras foram avaliadas em 3 períodos (inicial, antes da imersão, 24h e 10 dias após imersão em saliva artificial). Os valores obtidos pela transmitância direta, nos comprimentos de onda de 460 a 640 nm, foram submetidos à análise de variância a dois critéiros e teste de Tukey. Os resultados evidenciaram uma homogeneidade de valores entre as amostras e em função do tempo. Pode-se concluir que os valores de transmitância aumentaram significativamente conforme se aumentou os comprimentos de onda de 460 a 640 nm; O comportamento dos grupos experimentais foi similar em função do tempo, sendo que no tempo inicial e após 10 dias os resultados foram semelhantes entre si e estatisticamente superiores aos valores obtidos após 24 horas de imersão; O grupo G4 apresentou sempre a maior média de transmitância ao longo dos comprimentos de onda, em todos os tempos; Os grupos G6 e G7 foram semelhantes entre si com relação à transmitância e superiores aos grupos em ordem crescente de transmitância por G8=G2=G1>(G5=G3). / It was evaluated comparatively with ultra-visible spectrophotometer, the transmittance of 7 different composite resins: G1- Charisma A2; G2-Filtek Supreme A2E; G3- Filtek Supreme A2B; G4- Filtek Supreme YT; G5- Esthet-X A2; G6- Esthet-X YE; G7- Durafill A2, e G8- Z-100 A2.Ten samples (10 mm of diameter and 2 mm of thickness) were made for each experimental group. The samples were evaluated in 3 periods (initial, before the immersion, 24h and 10 days after immersion in artificial saliva). The values of the direct transmittance, in the wave lengths of 460 the 640 nm, were submitted to the two-way analysis of variance and Tukey's intervals. The results had evidenced homogeneity of values between the samples in function and of the time. It can be concluded that the values of transmittance had increased significantly if increased the wave lengths of 460 the 640 nm; The experimental groups reveled similar values in function of the time; the initial time and 10 days after immersion, the results had been similar between itself and superior to the values after 24 hours of immersion; The G4 group always presented the average greater of transmittance to the long one of the wave lengths, in all the times; The groups G6 and G7 had been similar between itself with relation to the transmittance and superiors to the groups orderly increasing of transmittance for G8=G2=G1>(G5=G3).
104

Estudo da contração de polimerização e do grau de conversão em função de diferentes resinas compostas e diferentes aparelhos fotopolimerizadores

Carlo, Hugo Lemes [UNESP] 19 October 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-10-19Bitstream added on 2014-06-13T18:51:43Z : No. of bitstreams: 1 carlo_hl_me_arafo.pdf: 663650 bytes, checksum: 1703d1cf829a007bfb4eb9e624207ea1 (MD5) / O objetivo deste trabalho foi avaliar a contração de polimerização linear e o grau de conversão de duas marcas comerciais de resinas compostas, com composições semelhantes, sendo uma de uso em dentes anteriores e posteriores (Filtek Z250) e outra para uso em dentes posteriores (Filtek P60). Também foi avaliado o efeito de diferentes fontes de luz nesse processo, utilizando-se para isso aparelho de luz halógena (Degulux - Degussa) e aparelho LED de alta intensidade (Ultrablue IS - DMC). Dessa forma, os materiais e fontes de luz foram divididos em quatro grupos: Grupo 1 - resina Filtek Z250 polimerizada com o aparelho de luz halógena (LH); Grupo 2 - resina Filtek Z250 polimerizada com aparelho LED (LED); Grupo 3 - resina Filtek P60 polimerizada com o aparelho de luz halógena (LH); Grupo 4 - resina Filtek P60 polimerizada com o aparelho LED (LED). A contração de polimerização foi medida com a inserção dos materiais em um anel plástico e a mensuração das alterações realizada por um instrumento eletrônico de medida linear com sensibilidade para 1 æm. O grau de conversão foi obtido através de teste de espectrometria no infravermelho por transformações de Fourier (FTIR), onde foram analisados os picos dentro das bandas de interesse nos valores de 1.646 cm-1 e 1.731 cm-1, correspondentes às ligações C=C alifática e C=O respectivamente. Os resultados foram submetidos à análise estatística de Variância e teste de Tukey (a = 0,05), os quais permitiram concluir que: a contração de polimerização de diferentes materiais (Filtek Z250 e Filtek P60) apresentou comportamento diferente mediante a mesma fonte luz (LED); o grau de conversão dos materiais apresentou-se estatisticamente semelhante em relação aos materiais e aparelhos fotopolimerizadores; o aparelho LED (Ultrablue IS) apresentou resultados de...
105

Avaliação imediata e após 6 meses da resistência de união a dentina de restaurações de resina composta classe I in vivo e in vitro

Rêgo, Heleine Maria Chagas [UNESP] 23 June 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-23. Added 1 bitstream(s) on 2016-06-07T17:17:18Z : No. of bitstreams: 1 000865416.pdf: 2581195 bytes, checksum: baec4e58131e8a8b1372e9f152ca300b (MD5) / Este estudo avaliou a resistência de união a dentina de restaurações de resina composta de forma imediata (24 horas) e em longo prazo (6 meses), submetidos a diferentes protocolos de envelhecimento. Cem dentes posteriores humanos foram divididos em cinco grupos (n = 20) de acordo protocolo de envelhecimento que receberam e posteriormente subdivididos em dois subgrupos (n = 10) de acordo com o tempo de armazenamento, totalizando dez subgrupos: In vivo (permaneceu em atividade bucal por 24 horas ou 6 meses); Estufa (armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem (submetidos a 27/666 ou 5000/120000 ciclos termomecânicos); Estufa com Pressão Pulpar Simulada (PPS) (restauração realizada sob PPS e em seguida armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem com PPS (restauração realizada sob PPS e em seguida submetidos a 27/666 -24 horas- ou 5000/120000 -6 meses- ciclos termomecânicos). Após a abertura da cavidade, a restauração foi realizada com a aplicação de ácido fosfórico a 37% (Vigodent), sistema adesivo Adper Single Bond 2 (3M ESPE) e resina composta Grandio (Voco), seguindo a orientação dos fabricantes. Após os diferentes tratamentos os espécimes foram seccionados obtendo-se palitos que foram submetidos ao teste de microtração. Os valores obtidos foram submetidos ao teste ANOVA dois fatores (protocolo de envelhecimento e tempo de armazenamento) e em seguida ao Teste de Tukey (5%). Os resultados para os testes de microtração foram (em MPa ±dp): Grupo estufa 24 h, 24,96±0,95A; Grupo ciclagem 24 horas, 23,96 ± 0,56AB; Grupo in vivo 24 horas, 23,21 ± 1,23AB; Grupo ciclagem com PPS 24 horas, 19,49 ± 1,51BC, Grupo ciclagem 6 meses, 18,16 ± 0,80CD; Grupo ciclagem com PPS 6 meses, 17,88 ± 1,25CD; Grupo estufa com PPS 24 horas, 17,65 ± 0,45CD; Grupo estufa 6 meses, 16,68 ± 1,30CD; Grupo estufa com PPS 6 meses, 14,33 ± 1,48D; Grupo in vivo 6 meses,.... / This study evaluated the bond strength of composite resin restorations submitted to different storage aging protocols, immediately and long-term (6 months). One hundred human posterior teeth were divided into five groups (n = 20) according storage aging protocol: Group, Group in vivo, Group water, Group cycling, Group water with Simulated Pulpal Pressure (PPS) and Group cycling with Simulated Pulpal Pressure. As further subdivided into two subgroups (n = 10) according to the time of storage were performed: 24 hours (24 hours in vivo 24 hours in water, 27/666 thermal and mechanical cycles) 6 months (6 months in vivo, 6 months in water and 5000/120000 thermal and mechanical cycles). After the opening of the cavity, the restoration was carried out with the use of phosphoric acid 37% (Vigodent), Single Bond 2 adhesive system (3M ESPE) and composite resin Grandio (Voco), following the lead of the manufacturers. After being held aging protocols for the storage time subgroup belonging specimens were sectioned obtaining sticks were submitted to microtensile test. Data were submitted to ANOVA two factors (aging and storage time) and then Tukey test (5%). The results for the microtensile tests were (MPa) ± SD: Group water 24 hours, 24.96 ± 0.95A; Group cycling 24 hours, 23.96 ± 0.56AB; Group in vivo 24h, 23.21 ± 1.23AB; Group cycling with PPS 24 hours, 19.49 ± 1.51BC, group cycling six months, 18.16 ± 0.80CD; Group cycling with PPS 6 months, 17.88 ± 1.25CD; Group water with PPS 24 hours, 17.65 ± 0.45CD; Group water 6 months, 16.68 ± 1.30CD; Group water with PPS 6 months, 14.33 ± 1,48D; In vivo group 6 months, 14.16 ± 1,51D. It was concluded that the different aging protocols used as storage times influence the bond strength dentin-resin
106

Efeito do selamento, reparo e recontorno sobre a longevidade de restaurações de resina composta em dentes posteriores segundo critério USPHS/RYGE

Fernández Godoy, Eduardo Maximiliano [UNESP] 15 July 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-15. Added 1 bitstream(s) on 2016-12-09T13:54:49Z : No. of bitstreams: 1 000867872.pdf: 1681629 bytes, checksum: 8c8d0ef7b0cc0f0f1c1d43325e7ab114 (MD5) / O objetivo geral deste trabalho foi determinar o efeito de selamento marginal, recontorno e reparo sobre a longevidade de restaurações de resina composta em dentes posteriores segundo Critério USPHS/Ryge. Foi realizado estudo experimental, longitudinal, prospectivo triplo-cego, incluímos 107 restaurações de resina composta de um grupo de 26 pacientes, de ambos os gêneros. Todos os pacientes foram recrutados na clínica da faculdade de Odontologia da Universidade do Chile em 2003 de acordo com os seguintes critérios de inclusão: apresentar restaurações de resina composta em dentes posteriores com defeitos, apresentando uma ou mais características clínicas classificadas como Bravo ou Charlie acordo com critérios USPHS/Ryge.Foram constituídos os seguintes grupos experimentais: 1.- Selamento, 2.- recontorno, 3.- Reparação, 4.- substituição, 5.- Sem intervenção.Os dentes dos voluntários foram avaliados e classificados pelo critério USPHS/Ryge por dois examinadores treinados e calibrados (0.75), A longevidade das restaurações foi avaliada antes da intervenção e após 1, 2, 3, 4, 5 e 10 anos de observação. Resultados, em geral, os grupos estudados mostraram restaurações clinicamente aceitáveis após dez anos de acompanhamento. O selamento e o recontorno mostraram efeito de melhoria imediata, que se perdeu ao longo do tempo (p<0.05). O reparo foi efetivo e apresentou resultados semelhantes a substituição total da restauração após 10 anos de uso clínico (p>0.05). Conclusão: O reparo aumentou a longevidade da restauração de resina composta em dentes posteriores por 10 anos enquanto o recontorno e o selamento marginal mostraram benefícios somente até 4 anos. Estes procedimentos minimamente invasivos mostraram-se validos e poderiam ser adotados pelos programas de saúde pública e pela faculdade...(Resumo completo, clicar acesso eletrônico abaixo) / The aim of this study was to determine the effect of marginal sealing, refurbishing and repair on the longevity of composite resin restorations in posterior teeth by criteria USPHS / Ryge. This clinical trial was longitudinal, tripleblind prospective. Were included 107 composite restorations of a group of 26 patients, of both genders. All patients were recruited in the clinic of Dentistry faculty of the University of Chile in 2003 according to the following inclusion criteria: presenting composite restorations in posterior teeth with defects, showing one or more clinical features classified as Bravo or Charlie according to USPHS / Ryge. According following criteria constituted the groups: 1.-Sealing, 2.-Refurbished 3. Repair, 4. No treatment and 5. Replacement. The restorations were evaluated and classified by USPHS criteria / Ryge by two trained and calibrated examiners (kappa 0.75), longevity of restorations was evaluated before the intervention and after 1, 2, 3, 4, 5 and 10 years. Results, in general, the groups showed restorations values acceptable to the ten year follow-up in the repair group, sealed and refurbished, the improvements were immediate and the effect remained se. Conclusions: Alternative treatments repair, sealing and refurbishing were able to improve some parameters deteriorated...(Complete abstract electronic access below)
107

Avaliação in vitro da rugosidade de superfície de uma resina composta coberta com selantes com ou sem carga quando submetida à abrasão por escovação com diferentes tipos de dentifrícios

Pressi, Heloísa January 2015 (has links)
Made available in DSpace on 2015-04-30T14:06:27Z (GMT). No. of bitstreams: 1 000467672-Texto+Completo-0.pdf: 1155191 bytes, checksum: e28fce24bd1c2748fbcead34d7bf4c08 (MD5) Previous issue date: 2015 / The objectives of this in vitro study were: 1) to evaluate the surface roughness of a composite resin covered by sealing surface containing inorganic filler or not, subject to brushing; 2) to analyze, with the aid of scanning electron microscopy, the presence of the sealant after 48 months of simulated toothbrushing; 3) verify that the type of toothpaste reduces the useful life of sealants; 4) verify the presence of inorganic filler prevents the increase in roughness forward to brushing. For this, 54 samples were made of composite resin and divided into nine groups: G1 - without composite sealant (control); G2 - Sealant Fortify, toothpaste Colgate Professional Whitening; G3 - Fortify, Colgate Total Clean Mint; G4 - Fortify, Edel White Whitening; G5 - Fortify, Edel White Gum Care; G6 - Fortify Plus, Colgate Whitening Professional; G7 - Fortify Plus, Colgate Total Clean Mint; G8 - Fortify Plus White Whitening Edel; G9 - Fortify Plus, Edel White Gum Care and analyzed the simulated periods of brushing (12,24, 36 and 48 months). Reading roughness was performed at baseline and after each simulated toothbrushing period, using a surface roughness (SJ 201 Mututoyo).Two specimens of each group were observed by SEM. The data were submitted to ANOVA and Tukey's test (5%). There was a significant difference between the two sealants, with the sealant Fortify Plus rougher. Among the toothpaste, Colgate Clean Mint associated with Fortify Plus sealant obtained the higher roughness values. Lower values were associated with Gum Care Fortify sealant. The protective layer formed by the sealant remained partially by the end of 48 months of brushing, maintaining the smoothness of the composite. We conclude that both sealants guaranteed protection of the composite, and the Fortify Plus rougher for all assessed toothpastes. Clinical significance: The roughness of the surface sealant is changed for different toothpastes and different times of brushing and the addition of inorganic filler in sealants promotes different performances in relation to surface roughness. / Os objetivos deste estudo in vitro foram: 1) avaliar a rugosidade de superfície de uma resina composta coberta por selantes de superfície contendo carga inorgânica ou não, submetidas à escovação simulada; 2) analisar, com auxílio da microscopia eletrônica de varredura, a presença dos selantes após 48 meses de escovação simulada; 3) verificar se o tipo de dentifrício diminui o tempo de vida útil dos selantes; 4) verificar se a presença de carga inorgânica previne o aumento da rugosidade frente à escovação. Para isto, foram confeccionadas 54 amostras de resina composta e divididas em nove grupos: G1 – compósito sem selante (controle); G2 – Selante Fortify, dentifrício Colgate Professional Whitening; G3 – Fortify, Colgate Total Clean Mint; G4 – Fortify, Edel White Branqueador; G5 – Fortify, Edel White Gum Care; G6 – Fortify Plus, Colgate Professional Whitening; G7 – Fortify Plus, Colgate Total Clean Mint; G8 – Fortify Plus Edel White Branqueador; G9 – Fortify Plus, Edel White Gum Care e analisados nos períodos simulados de escovação de 12, 24, 36 e 48 meses. A leitura da rugosidade foi realizada no baseline e após cada período de escovação simulada, utilizando um rugosímetro de superfície (SJ 201 Mututoyo). Dois corpos de prova de cada grupo foram observados em MEV. Os dados foram submetidos à ANOVA e Teste de Tukey (5%). Verificou-se diferença significativa entre os dois selantes, sendo o selante Fortify Plus mais rugoso. Entre os dentifrícios, o Colgate Clean Mint associado ao selante Fortify Plus obteve os maiores valores de rugosidade. Os menores valores observados foram com Gum Care associado ao selante Fortify. A camada de proteção formada pelos selantes permaneceu parcialmente até o final de 48 meses de escovação, mantendo a lisura do compósito. Conclui-se que ambos os selantes garantiram proteção da resina composta, sendo o Fortify Plus mais rugoso para todos os dentifrícios avaliados. Significância clínica: A rugosidade dos selantes de superfície é alterada em função de diferentes dentifrícios e diferentes tempos de escovação e a adição de carga inorgânica nos selantes promove desempenhos diferentes em relação à rugosidade superficial.
108

Análise da citotoxicidade de compósitos restauradores para técnica direta e indireta: estudo in vitro

Mildner, Mariele Diná January 2015 (has links)
Made available in DSpace on 2015-09-05T02:05:03Z (GMT). No. of bitstreams: 1 000474592-Texto+Completo-0.pdf: 757600 bytes, checksum: b10e64c161ec1e67c4e8d9aa24a580ae (MD5) Previous issue date: 2015 / An appropriate monomer conversion of composite resins is very important to improve your biocompatibility. The aim of this study was to evaluate additional polymerization methods of dental resins cytotoxicity. A total of 72 samples were prepared from the following materials: Filtek Z350XT® (3M/ESPE, St Paul, MN, EUA), Sinfony (3M/ESPE, St Paul, MN, EUA), Lava Ultimate (3M/ESPE, St Paul, MN, EUA). The used color was A2 for all composite resins. To Filtek Z350XT and Sinfony a Teflon mould (3x2mm) was used. From Lava Ultimate block 1,6mm cubes was cutting with diamond discs and digital pachymeter. Samples was divided in 4 groups: FK Group: 20s LED polymerization, S Group: Sinfony with light and vacuum additional polymerization, L Group: Lava Ultimate, FPA Group: Filtek Z350XT with light and vacuum additional polymerization. Evaluate specimens was stored in DMEM medium for 24, 48 and 72 hours respectively. Thereafter, culture medium was in contact with NIH/3T3 fibroblasts. MTT test determined cellular viability. Statistical analysis realized by Levene and Kolmogorov-Smirnov tests (α=0,05). The S group show the lower cytotoxicity. Additional polymerization of FK group wasn´t efficient to cellular viability. Sinfony presented minor cytotoxicity among all tested materials. Light and vacuum additional polymerization of Filtek Z350XT don´t improve your cytotoxicity results when compared with direct polymerization of the same dental composite. / Um satisfatório grau de conversão do monômero é importante para melhorar a biocompatibilidade das resinas compostas. O objetivo deste estudo foi avaliar o efeito dos métodos de polimerização adicional na citotoxicidade de diferentes compósitos restauradores. Para isso foram confeccionadas 18 amostras de cada uma das seguintes resinas testadas: Filtek Z350XT® (3M/ESPE, St Paul, MN, EUA), Sinfony (3M/ESPE, St Paul, MN, EUA), Lava Ultimate (3M/ESPE, St Paul, MN, EUA). A cor usada em todas as reinas foi a A2 de corpo. Para as resinas Filtek Z350XT e Sinfony utilizaram-se moldes de politetrafluoretileno de 3x2mm. Para a resina Lava Ultimate foram cortados do bloco cubos com 1,6mm de face usando um disco diamantado e paquímetro digital. As amostras foram divididas em 4 grupos: Grupo FK: Filtek Z350XT polimerizada por 20s com LED, Grupo S: Sinfony com polimerização adicional com luz e vácuo, Grupo L: Lava Ultimate, Grupo FPA: Filtek Z350XT com polimerização adicional com luz e vácuo. As espécies avaliadas estiveram em contato com meio DMEM por um período de incubação de 24, 48 e 72 horas respectivamente. Após, o meio de cultura foi colocado em contato com as células de fibroblastos NIH/3T3. Teste de MTT foi realizado para análise da viabilidade celular. Testes de Levene e Kolmogorov-Smirnov (α=0,05) foram utilizados para análise estatística. O grupo S apresentou-se com a citotoxicidade mais baixa. Já a polimerização adicional no grupo FK não mostrou-se eficiente para a viabilidade celular. A resina Sinfony apresentou a menor citotoxicidade dentre os três materiais analisados. Uma polimerização adicional por luz e vácuo na resina Filtek Z350XT não melhora seu resultado para citotoxicidade quando comparado a polimerização direta da mesma.
109

Avaliação da adaptação e da microinfiltração marginal de uma resina composta de incremento único frente a diferentes técnicas de fotoativação

Gamarra, Vania Stephanie Sánchez January 2016 (has links)
Made available in DSpace on 2016-04-13T12:03:53Z (GMT). No. of bitstreams: 1 000477938-Texto+Parcial-0.pdf: 192614 bytes, checksum: ac0bcd8326b2183c17301f29601b81ee (MD5) Previous issue date: 2016 / The aim of this study was to evaluate, in vitro, the marginal adaptation and microleakage of class II restorations of SonicFill composite resin with different curing techniques. Class II preparations were prepared in 40 human premolars (mesial margin 1 mm below the CEJ, distal margin 1 mm above the CEJ), and randomly divided into 4 groups according to curing technique (n = 10 per group): G1: 1200 mW/cm2 for 20 s; G2: 1200 mW/cm2 for 40 s; G3: Soft-start for 20 s (650 mW/cm2 for 5 s, increasing to 1200 mW/cm2 for 15 s); G4: Soft-start for 40 s (650 mW/cm2 for 10 s, increasing to 1200 mW/cm2 for 30 s). Three-step etch&rinse adhesive Optibond FL was applied and the cavity was filled in bulk with SonicFill composite resin, followed by oclusal sculpture and photoactivation. Impressions were made using polyvinyl siloxane and epoxy resin replicas were obtained, before and after thermocycling. The occlusal and cervical margins were analyzed with SEM at 200x magnification. The marginal adaptation was expressed as percentages of continuous margins. After thermocycled, the specimens were immersed in silver nitrate 50%, and analyzed the extention of dye penetration in the cervical-mesial and cervical-distal margins. According to ANOVA and Tukey’s test, there was statistical difference in the percentage of continuous margins on the occlusal-palatine for group 1 (83. 19%), differing statistically from groups 2, 3 and 4 that had values over 95% for continuous margins (p≤0,05).In the cervical margin there was no statistical difference between the groups (p≥0,05). According to Student's t test, after thermocycling, there was a statistical significant reduction of percentage of continuous margins in occlusal-buccal margin for groups 1, 2 and 4, as well as in the cervical-mesial margin for groups 1, 3 and 4, and cervical-distal margin only to group 1. According to Kruskal-Wallis test, there was no significant difference in the microleakage scores between groups in the enamel (p=0. 373) and in dentin (p=0. 561), being predominantly score 1 in enamel and score 3 in dentin. The bulk filling technique with SonicFill composite resin associated with three-step etch&rinse adhesive Optibond FL in class II cavities provided gap formation and microleakage, especially in the cervical dentin region, regardless of the curing technique. / O objetivo do estudo foi avaliar, in vitro, a adaptação e o selamento marginal de restaurações classe II em resina composta SonicFill com diferentes técnicas de fotoativação. Foram realizados preparos classe II em 40 pré-molares humanos (caixa mesial 1 mm abaixo da JCE, caixa distal 1 mm acima JCE), sendo divididos aleatoriamente em 4 grupos de acordo com a técnica de fotoativação (n = 10 por grupo): G1: 1200 mW/cm2 por 20 s; G2: 1200 mW/cm2 por 40 s; G3: Soft-start por 20 s (650 mW/cm2 por 5 s, elevando para 1200 mW/cm2 por 15 s); G4: Soft-start por 40 s (650 mW/cm2 por 10 s, elevando para 1200 mW/cm2 por 30 s). O sistema adesivo Optibond FL foi aplicado e a cavidade foi preenchida em incremento único com a resina composta SonicFill, seguido da escultura da oclusal e fotoativação. A partir de moldagens com silicone por adição, foram obtidas réplicas em resina epóxica das restaurações antes e após termociclagem. As margens das réplicas, ao nível oclusal e cervical, foram analisadas no MEV em 200x, sendo determinada a porcentagem de margens continuas. Após termociclagem, os corpos de prova foram submetidos à metodologia de microinfiltração com nitrato de prata a 50%, sendo analisada a extensão da penetração na margem cervical mesial e distal. De acordo com ANOVA e teste de Tukey, houve diferença estatística na porcentagem de margens contínuas na oclusal-palatina para o grupo 1 (83,19%), diferindo estatisticamente dos grupos 2, 3 e 4 que tiveram valores acima de 95% para margens contínuas (p≤0,05).Na margem cervical não houve diferença estatística entre os grupos (p≥0,05). De acordo com o teste t-student, após termociclagem, houve redução estatisticamente significativa na porcentagem de margens continuas na margem oclusal-vestibular para os grupos 1, 2 e 4, assim como na margem cervical-mesial para os grupos 1, 3 e 4, e na região cervical-distal apenas para o grupo 1. De acordo com o teste de Kruskal-Wallis, não houve diferença significativa para os escores de microinfiltração entre os grupos, tanto no esmalte (p=0,373) como na dentina (p=0,561), sendo predominantemente escore 1 em esmalte e escore 3 em dentina. A técnica de incremento único com a resina composta SonicFill, associada ao sistema adesivo Optibond FL, em cavidades classe II, proporcionou a formação de fendas e a ocorrência de microinfiltração, principalmente na região cervical com término em dentina, independente da técnica de fotoativação.
110

Obtenção de compósitos de borracha natural com resíduo industrial de couro reticulados com diferentes peróxidos /

Santos, Renivaldo José dos. January 2014 (has links)
Orientador: Aldo Eloizo Job / Banca: José Antonio Malmonge / Banca: Ana Maria Pires / Banca: Eduardo Ribeiro de Azevedo / Banca: Maria Alice Martins / Resumo: Processos de curtimento de couro têm causado impacto ambiental como resultado da geração de resíduo sólido, resíduos provenientes do processo de lavagem do couro (waterwaste) bem como a liberação de gases durante os procedimentos. O descarte inapropriado deste resíduo pode promover, por exemplo, a oxidação do cromo, passando de Cr III para Cr IV, tornando-se extremamente tóxico. Além disso, o descarte apropriado do resíduo (principalmente o resíduo sólido) em aterros regularizados aumenta consideravelmente o custo de produção para a indústria de couro. Baseado nestas informações, esta tese de doutorado, reporta um método de reciclagem de resíduo industrial de couro (coletado na região de Presidente Prudente) implementado na preparação de compósitos de borracha natural, variando a quantidade de resíduo incorporado nos compósitos de 40 e 80 phr, bem como avaliado o uso de diferentes agentes de vulcanização, os quais são peróxido de dicumila (DCP), peróxido 2,5 Dimetil Hexano 2,5 Di Terc-Butil, (DHBP) e enxofre (S), todo obtidos comercialmente. Os compósitos foram preparados sob alta pressão e nas de temperaturas de 150 e 180ºC. A caracterização foi realizada utilizado reometria, cálculo de energia da ativação aparente, determinação da densidade de ligações cruzadas por inchamento e ressonância magnética nuclear, ensaio de envelhecimento acelerado, resistência a tração na ruptura, resistência a abrasão, dureza Shore A, microscopia eletrônica de varredura (MEV), espectroscopia por FT-IR no modo ATR, calorimetria exploratória diferencial (DSC), termogravimetria (TG) acoplada a espectroscopia no infravermelho (TG/FTIR), análise dinâmica mecânica (DMA) e lixiviação. O principal resultado demonstra que aumentando a quantidade de resíduo de couro aumenta-se a tensão de ruptura e resistência ao desgaste, apresentando boa reprodutibilidade bem como uniformidade na distribuição do resíduo... / Abstract: Leather tanning processes have occasioned environmental impact as a result of the generation of solid waste, wasterwater and release of gases during the procedures. The improper disposal of such waste may promote the oxidation of chromium, increasing the Cr III to Cr IV, in which becomes extremely toxic. Furthermore, the appropriate disposal of the residue (mainly solid residue) at regularized landfil increase substantialy the production cost to the leather industry. Based on this information, this Ph.D. thesis reports a new method to recycling industrial leather waste (collected around Presidente Prudente city) implemented on preparation of natural rubber composites varying the amount of residue between 20 and 80 phr as well as evaluating different curing agents (crosslink generation) using dicumyl peroxide (DCP), peroxide 2,5 Dimethyl Hexane 2.5 Di Tert. Butyl (DHBP) and sulfur (S) obtained commercially. The composites were prepared under high pressure at a range of temperature of 150 to 180ºC. Moreover, the characterization was performed using, rhemetry, calculation of the apparent activation energy, determination of crosslink density by swelling and nuclear magnetic resonance, accelerated aging tests, stress-strain tests (rupture resistance at break), abrasion resistance, hardness Shore A, scanning electron microscopy (SEM), FT-IR spectroscopy in ATR mode, differential scanning calorimetry (DSC), thermalgravimetric (TG) coupled to infrared spectroscopy (TGA/FTIR), dynamic mechanical analysis (DMA) and evaluation of the leaching compounds. The main result showed that increasing the waste leather amount increased the tensile strength and abrasion resistance, with good reproducibility and uniformity of residuals distribution as fillers (miscible materials). The production of the natural rubber/leather waste composite lead to a correct management to the leather waste into a viable industrial application, eliminating a major... / Doutor

Page generated in 0.0724 seconds