• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Características da lesão de cárie secundária adjacente a restaurações de resina composta

Silva, Berenice Barbachan e January 2006 (has links)
O diagnóstico da cárie secundária é apoiado em evidências externas, advindas do estado da restauração adjacente, que tem pouca ou nenhuma relação com a presença real dessa lesão. É imperativo o esclarecimento das suas características objetivando o aprimoramento da sua detecção. O estudo analisou lesões de cárie secundária e as relacionou com defeitos nas restaurações. A amostra constou de caixas proximais de restaurações de resina composta de dentes permanentes humanos extraídos. Os exames realizados com lupa estereoscópica avaliaram as lesões de cárie externa adjacente à restauração, o estado da restauração quanto à presença de espaços dente/restauração (EDR) e degraus (excessos e a falta de material restaurador). Após a remoção das restaurações, foi observada a presença de lesão interna na parede da cavidade. Do exame de cárie externa foram selecionados 60 sítios sadios ou com lesão inicial, para a análise histológica do início do seu desenvolvimento. Os defeitos nas restaurações apresentaram relação com a prevalência de cárie secundária. A presença de lesão interna na parede da cavidade foi associada à presença de cárie externa. Em apenas 8% da amostra foi observada a presença de lesão interna em dentina sem a presença de lesão externa, podendo significar dentina desmineralizada residual. A análise histopatológica demonstrou que as lesões de cárie secundária iniciam na porção externa da interface dente/restauração. A morfologia histológica das lesões iniciais apresentou dois padrões, relacionados com a direção dos prismas de esmalte envolvidos: (1) prismas oblíquos e (2) prismas paralelos à base da parede cervical da cavidade. A prevalência foi aproximadamente de 50% para cada padrão. O padrão 2 oferece imagem semelhante à lesão de parede; porém, a lesão inicia externamente e envolve a base da cavidade, em função do paralelismo dos prismas envolvidos. Através dos resultados do estudo pôdese concluir que os defeitos nas restaurações apresentam relação com a presença de cárie secundária, provavelmente por serem locais de acúmulo microbiano; porém, comprovou-se que a lesão inicia externamente na interface dente/restauração, local passível de diagnóstico, controle e inativação.
82

Eficácia do LED na polimerização de um compósito

Campregher, Ulisses Bastos January 2003 (has links)
O objetivo deste estudo foi avaliar a eficácia de três aparelhos fotopolimerizadores comerciais que utilizam o LED como fonte de luz (Elipar FreeLight - 3M-ESPE, UltraLume-LED2 - Ultradent e Single V - BioArt) na polimerização do compósito Z250 (3M-ESPE), cor A3, através das propriedades: microdureza Knoop, profundidade de polimerização e resistência flexural. Um aparelho fotopolimerizador convencional de lâmpada halógena XL 2500 (3M-ESPE) foi utilizado como controle. Em todos os casos, o tempo de polimerização adotado foi de 20 s. Para o ensaio de microdureza foram confeccionados 10 corpos de prova cilíndricos com 8 mm de diâmetro e 2 mm de altura para cada aparelho fotopolimerizador. A microdureza foi medida 24 h após a confecção dos corpos de prova, que ficaram armazenados em ambiente seco e protegidos da luz. Para o ensaio de profundidade de polimerização foram confeccionados três corpos de prova cilíndricos com 4 mm de diâmetro e 6 mm de altura para cada aparelho fotopolimerizador. O ensaio foi realizado imediatamente após a polimerização do compósito. Para o ensaio de resistência flexural foram confeccionados 5 corpos de prova com 25 mm de comprimento, 2 mm de altura e 2 mm de largura para cada aparelho fotopolimerizador. A resistência flexural foi medida 24 h após a polimerização do compósito e armazenagem dos corpos de prova em água destilada a 37ºC. Os resultados obtidos foram comparados às exigências da especificação 4049:2000 da International Organization for Standardization (ISO) e submetidos à análise estatística para comparação entre os aparelhos. Os valores de microdureza obtidos com os três fotopolimerizadores com LED não mostraram diferença entre si e foram superiores aos obtidos com o aparelho convencional. Para o ensaio de profundidade de polimerização, os valores obtidos com o aparelho Single V foram superiores aos do aparelho convencional, enquanto que os obtidos pelos outros dois aparelhos não apresentaram diferenças significativas entre si e o convencional. Para o ensaio de resistência flexural, não houve diferença entre os valores obtidos pelos três aparelhos com LED e o aparelho convencional. As exigênias da ISO 4049:2000 para os ensaios de profundidade de polimerização e resistência flexural foram atendidas em todos os casos.
83

Estudo in vitro da microinfiltração marginal em reparos de restaurações de resina composta após irradiação com laser de Er:YAG

Moura, Altair Soares de January 2004 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T13:28:37Z No. of bitstreams: 1 Altair Soares Moura.pdf: 1162342 bytes, checksum: 441e2dd313cf9d6697463b4ebb97043e (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:59:03Z (GMT) No. of bitstreams: 1 Altair Soares Moura.pdf: 1162342 bytes, checksum: 441e2dd313cf9d6697463b4ebb97043e (MD5) / Made available in DSpace on 2013-05-08T11:59:04Z (GMT). No. of bitstreams: 1 Altair Soares Moura.pdf: 1162342 bytes, checksum: 441e2dd313cf9d6697463b4ebb97043e (MD5) Previous issue date: 2004 / O reparo de restaurações em resina composta é uma prática muito empregada, sendo o Laser de Er:YAG uma das possibilidades de tratamento. Este estudo visa analisar ?in vitro? a microinfiltração em reparos de restaurações com resina composta (resina/resina) cuja superfície foi tratada com Laser de Er:YAG. Quarenta terceiros molares humanos receberam preparos cavitários na face vestibular que foram restaurados com resina composta. Os dentes foram divididos em oito grupos de cinco dentes cada em função do tratamento da superfície que variou em: G1 e 2 foram repreparados com ponta diamantada esférica e reparados com resina, sendo utilizado no G1 - ácido fosfórico 37% + sistema adesivo, G2 - sistema adesivo. Nos grupos 3 a 8, o Laser de Er:YAG foi usado na produção de um defeito da seguinte maneira: G3 (3hZ,60mJ,6J,103 pulsos). G4 (4hZ, 60mJ, 6J, 103 pulsos), G5 (3hZ, 100mJ, 6J, 63 pulsos). G6 (4hZ, 100mJ, 6J, 63 pulsos). G7 (3hZ, 120mJ, 6J, 54 pulsos), e G8 (4hZ, 120mJ, 6J, 55 pulsos); e reparados com resina empregando sistema adesivo sem condiconamento ácido prévio. Os corpos de prova foram termociclados (500 ciclos) e imersos em Nitrato de Prata a 50% por 24 horas. Os resultados da análise (ANOVA) evidenciaram que a menor microinfiltração foi observada quando 4Hz, 60mJ, 6J e 103 pulsos e 4 Hz, 120mJ, 6J e 55 pulsos foram utilizados. / Salvador
84

Efeito do pré-tratamento térmico na contração volumétrica de uma resina composta microhíbrida por meio de análise de vídeo-imagem / Fabiane Borges de Liz ; orientadora, Evelise Machado de Souza

Liz, Fabiane Borges de January 2012 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / O objetivo deste estudo in vitro foi avaliar por meio de vídeo imagem a contraçãovolumétrica de uma resina composta microhíbrida fotoativada com luz halógena e LED (diodo emissor de luz) após o pré-tratamento térmico com temperaturas de 4ºC, 37ºC e 60ºC. / The aim of this study was to evaluate in vitro by means of a video-imaging technique the volumetric shrinkage of a microhybrid resin composite light-cured with halogen and LED (Light Emitting Diode) after to thermal pre-treatment of 4°C, 37°C and 60°C. Th
85

Translucidez e luminosidade de compósitos para esmalte em diferentes espessuras

Almeida, Adriano Gondim January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:11:07Z (GMT). No. of bitstreams: 1 329193.pdf: 1313839 bytes, checksum: c5836a71fbfccf7fea68838081ee8ff1 (MD5) Previous issue date: 2014 / O objetivo deste estudo foi avaliar in vitro a influência da espessura de resina composta para esmalte, baseadas ou não na escala vita clássica nos parâmetros de luminosidade e translucidez. Um dispositivo de resina epóxica foi criado e confeccionado pelo método de estereolitografia para possibilitar a confecção de espécimes de resina composta em forma de um incisivo central superior que apresentavam as camadas de esmalte palatal, dentina e variação de três espessuras de esmalte vestibular: 0,4mm; 0,8mm e 1,2mm. Os materiais testados foram os compósitos, Filtek Z350 XT(3M ESPE), Miris 2(Coltène) e Ena HRi (Micerium). Foram feitas três leituras de cor para cada espécime utilizando o espectrofotômetro Vita Easy Shade (Vita Zahnfabrik). Pela análise estatística foram calculadas as médias das leituras e os parâmetros de translucidez e luminosidade. Os resultados mostram diferenças significativas entre os compósitos e entre as espessuras, sendo os maiores valores de luminosidade e menores graus de translucidez para o compósito Ena HRi e maiores valores de translucidez para o compósito Miris 2. Pode se concluir que os parâmetros de cor dependem do compósito utilizado e ainda da espessura utilizada.<br> / Abstract: The aim of this study was to evaluate in vitro the translucency parameter and lightness using enamel composite resin with different thicknesses, based or not on the Vita Classical shade guide. An epoxic resin device was developed and built by stereolithography process to enable the manufacture of specimens with the shape of an upper central incisor using composite resin. The specimens had layers of palatal enamel, dentin, and three diferente thicknesses of buccal enamel: 0.4mm, 0.8mm and 1.2mm. The composites tested were Filtek Supreme Ultra (3M ESPE), Miris 2 (Coltène) and Ena HRi (Micerium). The spectrophotometer Vita Easy Shade Vita Zahnfabrik) was used to perform three color measurements of each specimen. Measurement means were calculated and through statistical analysis translucency parameter and lightness were also calculated. The results showed significant differences between the composites used and their thicknesses. The values of lightness were higher for lightness and the translucency was higher for the composite Miris 2. It can be concluded that the color parameters evaluated depend on the composite used and their thickness.
86

Avaliação do tempo e condição de armazenagem na fluência em resinas compostas

Savi, Camila Gonçalves January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-09-01T04:09:50Z (GMT). No. of bitstreams: 1 333865.pdf: 1179205 bytes, checksum: 0a8565618e9602afd5846cb955ca415c (MD5) Previous issue date: 2015 / Objetivo: Avaliar o comportamento viscoelástico (creep) de resinas compostas dentais sob teste de fluência por microindentação Vickers, em duas condições diferentes: tempo (24 h e 1 mês) e armazenagem (seco e úmido), com carga e temperatura constantes. Material e Método: Cem amostras cilíndricas (12 mm x 1 mm), foram confeccionadas a partir de 5 resinas compostas (Micro- híbrida, Nano-Híbrida, Micro-híbrida com nanopartículas, Nanopartículada eNano-híbrida), divididas em dois subgrupos de acordo com a armazenagem (seco e úmido) (n = 10), em estufa a ± 37º C. Após operíodo de armazenagem concluído (24h e 1 mês), as amostras receberam uma carga compressiva estática de 100 g por 30 s em um microdurometro, permaneceram sob relaxamento (sem carga) de 30 s e foram mensuradas, repetiu-se o teste no mesmo local e uma nova mensuração foi realizada. Os valores dessas indentações foram armazenados e calculados. Resultados e Conclusão: A Resina Opallis apresentou o maior valor para a fluência do que as outras resinas. Os menores valores foram encontrados na Filtek Z350. Não houve diferença estatisticamente significante entre IPS Empress Direct e Charisma Diamond (P> 0,05). Também não houve diferença significante entre Filtek Z250 e IPS Empress Direct (P> 0,05). Porém, Filtek Z250 apresentou diferença da Charisma Diamond. As resinas tiveram uma menor deformação de fluência quando armazenadas a seco para todos os grupos. Quanto ao tempo de armazenagem em 24h teve maior deformação do que 1 mês.<br> / Abstratct: To evaluate the viscoelastic behavior (creep) of dental composite resins under fluency test by microindentação Vickers, in two different conditions: time (24 hours and 1 month) and storage (dry andwet), load and temperature constant. Method: Hundred cylindrical samples (12 mm x 1 mm), were prepared from 5 resins composite (Micro-hybrid, Nano-Hybrid, Microhybridwith nanoparticles, Nanoparticle and nano-hybrid) were dividedinto two subgroups according to storage (dry and wet) (n = 10), in anoven at 37 º ± C. After the period concluded storage (24 h and 1 month), the samples have received a static compressive load of 100 g for 30 s in the microhardness, remained under relaxation (no load) for 30 s and were measured, the test was repeated in the same place and a new measurement was performed. The values of these indentations werestored and calculated. Results and Conclusion: The Opallis resin showed the highest valueto fluency than other resins. The lowest values were found in FiltekZ350. There was no statistically significant difference between IPS Empress Direct and Charisma Diamond (P> 0.05). There was also no significant difference between Filtek Z250 and IPS Empress Direct (P>240.05). However, Filtek Z250 showed a difference of Charisma Diamond. The resins had a lower creep deformation when stored the dry for all groups and in relation to storage period 24 h with a greater deformation than 1 month.
87

Obtenção de nanobiocompósitos magnéticos constituídos de Galactomanana, Glicerol e Ferrita de Níquel e Zinco / Obtaining magnetic nanobiocompósitos consisting of galactomannan, glycerol and nickel ferrite and zinc

Souza, Natália Dantas Gomes de 02 February 2014 (has links)
SOUZA, N. D. G. Obtenção de nanobiocompósitos constituídos de Galactomanana, Glicerol e Ferrita de Níquel e Zinco. 2014. 73 f. Dissertação (Mestrado em Engenharia e Ciências de Materiais) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-02-20T17:45:35Z No. of bitstreams: 1 2014_dis_ndgsouza.pdf: 1952609 bytes, checksum: f381be27d3e7e554b43f06e5bac38601 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-02-24T16:38:50Z (GMT) No. of bitstreams: 1 2014_dis_ndgsouza.pdf: 1952609 bytes, checksum: f381be27d3e7e554b43f06e5bac38601 (MD5) / Made available in DSpace on 2015-02-24T16:38:51Z (GMT). No. of bitstreams: 1 2014_dis_ndgsouza.pdf: 1952609 bytes, checksum: f381be27d3e7e554b43f06e5bac38601 (MD5) Previous issue date: 2014-02-02 / In recent years, a great interest in the association of magnetic and biological materials has been reported in the literature. New composite consisting of galactomannan (GM), magnetic nanoparticles (NPs) of NiZn and glycerol (GL) were produced in different proportions with the purpose of enhancing the individual characteristics of each material for future applications. Thus, the structural, magnetic and dielectric properties of nanobiocomposites were investigated by Absorption Spectroscopy in the Region of Infrared (FTIR), X-Ray Diffraction (XRD), Thermal Analysis (TG), Differential Scanning Calorimetry (DSC), Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), Magnetic Measurements and Dielectric Measurements. The structure of spinel NiZn ferrite was confirmed by XRD and TEM. Sample GMGL despite being an amorphous material presented in their nanobiocomposites characteristic peaks of phase NiZn. The characteristic bands in the samples were confirmed by FTIR. These in turn followed a degradation profile in accordance with the amounts of NiZn incorporated, which was confirmed in the DSC thermograms. The characterization by SEM was important to assess the morphology. The results of dielectric measurements showed low dielectric loss and magnetic measurements showed magnetic behavior for all nanobiocomposites. Therefore, the results of the characterization of nanobiocomposites were satisfactory for potential applications as biomaterials, electronic devices or related areas. / Nos últimos anos, um grande interesse na associação de materiais magnéticos e biológicos tem sido relatado na literatura. A obtenção de novos compósitos constituídos de galactomanana (GM), nanopartículas magnéticas (MNPs) de NiZn e glicerol (GL) foram produzidos em diferentes proporções com finalidade de potencializar as características individuais de cada material para futuras aplicações. Sendo assim, as propriedades estruturais, magnéticas e dielétricas dos nanobiocompósitos foram investigadas por Difração de Raios-X (DRX), Espectroscopia de Absorção na Região de Infravermelho (FTIR), Análise Térmica (TG), Calorimetria Exploratória Diferencial (DSC), Microscopia Eletrônica de Varredura (MEV), Microscopia Eletrônica de Transmissão (TEM), Medidas Magnéticas e Medidas Dielétricas. A estrutura de espinélio da ferrita de NiZn foi confirmada por DRX e TEM e a amostra GMGL apesar de ser um material amorfo apresentou em seus nanobiocompósitos picos caracteristicos da fase de NiZn. As bandas características para as amostras foram confirmadas por FTIR. Estas por sua vez seguiram um perfil de degradação de acordo com as quantidades de NiZn incorporados, confirmados nos termogramas de DSC. A caracterização por MEV foi importante para avaliação da morfologia. Os resultados das medidas dielétricas apresentaram baixas perdas dielétricas e das medidas magnéticas mostraram comportamento magnético para todos os nanobiocompósitos. Portanto, os resultados da caracterização dos nanobiocompósitos foram satisfatórios para possíveis aplicações como biomaterias, dispositivos eletrônicos ou em áreas afins.
88

Avaliação in situ do efeito anticariogênico de diferentes materiais restauradores / Anticariogenic in situ effect of different restorative dental materials

Sousa, Rosane Pontes de January 2008 (has links)
SOUSA, Rosane Pontes de. Avaliação in situ do efeito anticariogênico de diferentes materiais restauradores. 2008. 44 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2008. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-19T11:48:12Z No. of bitstreams: 1 2008_dis_rpsousa.pdf: 561097 bytes, checksum: 6d1b64b12b6307b9104b25b9def3697d (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-02T16:01:06Z (GMT) No. of bitstreams: 1 2008_dis_rpsousa.pdf: 561097 bytes, checksum: 6d1b64b12b6307b9104b25b9def3697d (MD5) / Made available in DSpace on 2012-02-02T16:01:06Z (GMT). No. of bitstreams: 1 2008_dis_rpsousa.pdf: 561097 bytes, checksum: 6d1b64b12b6307b9104b25b9def3697d (MD5) Previous issue date: 2008 / Tooth structure immediately adjacent to restorations is susceptible to secondary caries, which may be caused by imperfect adaptation of restorative materials and subsequent microorganism colonization. Therefore, in order to identify methods of preventing secondary caries and increasing clinical dental restoration durability, different restorative dental materials have been introduced and applied in dental clinics. Thus, this in situ study assessed the effects of different restorative materials on the microbiological composition of dental biofilm and evaluated their ability of protecting the adjacent enamel against acid attacks from bacterial activity. A double-blind, split-mouth design was performed in one phase of 14 days, during which, 20 volunteers wore intra-oral palatal devices with five human enamel slabs, which were extra-orally restored according to the manufacturer’s specifications, using one of the following materials: Filtek Z 250/Single Bond composite resin; Permite amalgam; Fuji II encapsulated resin-modified glass ionomer; Vitremer resin-modified glass ionomer and Ketac Molar conventional glass ionomer.. During the experimental period, all subjects used fluoride-containing dentifrice 3x/day and a 20% sucrose solution was dripped onto the slabs 8x/day in predetermined times. The biofilm formed on the slabs was analyzed to determine total and mutans streptococci as well as lactobacilli counts. Demineralization (delta S) was determined on enamel by cross-sectional microhardness at 20 and 70 -µm from the restoration margin. In order to verify the differences among the treatments, Kruskal-Wallis and ANOVA followed by Minimum Squares test were applied for cariogenic microbiota and delta S, respectivly. No statistically significant differences were found in the cariogenic microbiota grown on the slabs. At 20-µm distance, only Fuji II statistically differed from the other groups presenting the lowest demineralization. At 70-µm, Fuji II significantly inhibited demineralization when compared to Permite, Filtek-Z-250 and Ketac Molar. Concluding, in the background of fluoride dentifrice and under the cariogenic exposure condition of this study, only the encapsulated resin-modified glass ionomer material provided additional protection against secondary caries. / A estrutura dentária imediatamente adjacente a restaurações é suscetível ao surgimento de cárie secundária, que pode ocorrer devido a imperfeições na adaptação de materiais restauradores e subseqüente colonização por microrganismos. Logo, com o objetivo de identificar os métodos de prevenção da cárie secundária e aumentar a longevidade das restaurações, diferentes materiais restauradores têm sido introduzidos e usados na clínica odontológica. Desta forma, este estudo in situ avaliou os efeitos de diferentes materiais restauradores na composição microbiológica do biofilme dental bem como a habilidade destes materiais em proteger o esmalte adjacente dos ataques ácidos provenientes da atividade bacteriana. Foi empregado um delineamento duplo-cego, “split-mouth” realizado em uma fase de 14 dias, durante a qual, 20 voluntários utilizaram dispositivos intra-orais palatinos com cinco blocos de esmalte dental humano que foram restaurados extra-oralmente, de acordo com as recomendações do fabricante com um dos seguintes materiais: Resina composta Filtek Z250/Single Bond (grupo controle), Amálgama Permite, Ionômero de vidro modificado por resina encapsulado Fuji II, Ionômero de vidro modificado por resina Vitremer e Ionômero de vidro convencional Ketac Molar. Durante o período experimental, os voluntários utilizaram dentifrício fluoretado, 3 vezes ao dia e gotejaram sobre os blocos, uma solução de sacarose a 20%, 8 vezes ao dia em horários pré-determinados. No 14o dia, o biofilme formado sobre os blocos foi removido para determinar a contagem de estreptococos totais e estreptococos mutans, bem como lactobacilos. A desmineralização (delta S) ao redor da restauração foi avaliada através da análise de microdureza em corte longitudinal do esmalte a 20 e 70 µm da margem da restauração. Para detectar as diferenças entre os tratamentos, foram aplicados os testes Kruskal-Wallis e ANOVA seguida do teste dos quadrados mínimos para a microbiota cariogênica e delta S, respectivamente. Não foram encontradas diferenças estatisticamente significativas na microbiota cariogênica formada sobre os blocos. Na distância 20 µm, somente o Fuji II diferiu estatisticamente dos outros grupos apresentando a menor desmineralização. A 70 µm, o Fuji II inibiu significativamente a desmineralização quando comparado ao Permite, Filtek-Z-250 e Ketac Molar. Conclui-se que na situação de uso de dentífricio flouretado associada ao desafio cariogênico do presente estudo, somente, o ionômero de vidro modificado por resina encapsulado apresentou uma proteção adicional contra o desenvolvimento de cárie secundária.
89

Preparação e caracterização de monômeros metacrílicos com potencial aplicação em resinas compostas restauradoras

Andreani, Larissa January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Química, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T22:05:30Z (GMT). No. of bitstreams: 1 314258.pdf: 2686265 bytes, checksum: c03642564838a6f84b4a7e996675850c (MD5) / Durante muitos anos, a odontologia utilizou ligas de ouro ou amálgama na restauração de dentes com cáries ou outros danos. Recentemente, por questões estéticas, estas ligas metálicas têm sido substituídas pelas chamadas resinas compostas restauradoras, formadas por monômeros metacrílicos e dimetacrílicos, entre outros componentes. Este trabalho dedicou-se ao desenvolvimento de monômeros metacrílicos com potencial utilização na formação de resinas compostas restauradoras. Metacrilatos apresentando diversas estruturas foram sugeridos. Os monômeros CMEE-2 (42), CMEE-4 (44) e CMEE-H (54) apresentaram os melhores resultados de síntese e passaram para a próxima etapa, que consistiu na utilização destes monômeros na formação de uma matriz polimérica juntamente com um monômero dimetacrílico usualmente utilizado na restauração dental (BisEMA, 6) e por um sistema fotoiniciador. As matrizes poliméricas formadas com a inclusão destes monômeros experimentais tiveram diversas propriedades avaliadas: grau de conversão após a fotopolimerização, dureza Vickers, temperatura de transição vítrea, morfologia de superfície e seção transversal, absorção de água e solubilidade em água. Entre as formulações estudadas, o sistema preparado com o monômero CMEE-H (54) apresentou os resultados mais promissores, pois participou na formação de uma matriz reticulada mais densa (mesmo não apresentando o maior grau de conversão) e apresentou o maior valor de dureza Vickers. Além disso, os valores de solubilidade e absorção de água obtidos mostraram-se satisfatórios. Visando sua aplicação em resinas compostas restauradoras, tanto o sistema preparado com a adição de CMEE-H (54) quanto os demais sistemas testados devem sofrer algumas melhorias e modificações, em especial o aumento nos valores de grau de conversão (aumentando o tempo de exposição à fonte luminosa, por exemplo) e redução nos resultados de absorção de água (adicionando ao sistema partículas inorgânicas de carga). No entanto, este estudo apresenta uma alternativa viável para a substituição de monômeros metacrílicos comerciais, levando à formação de matrizes poliméricas que apresentam desempenho equivalente ou superior às matrizes preparadas com monômeros disponíveis comercialmente.<br> / Abstract : For many years, the dentistry field have used gold alloys or amalgam in the restoration of carious or damaged teeth. Recently, for aesthetic reasons, these alloys are being replaced by the so-called restorative composite resins, formed by methacrylic and dimethacrylic monomers, among other components. This work is devoted to the development of methacrylic monomers with potential use as component in these restorative composite resins. Methacrylates presenting different structures have been suggested. The monomers CMEE-2 (42), CMEE-4(44) and CMEE-H (54) showed the best synthetic results and were selected for further studies, which consisted of utilizing these monomers in the formation of a polymeric matrix in combination with a dimethacrylic monomer commonly used in dental restoration (BisEMA, 6) and a photoinitiator system. The polymeric matrices formed with inclusion of these experimental monomers were evaluated regarding the following properties: degree of conversion after photopolymerization, Vickers hardness, glass transition temperature, surface and cross-section morphology, water sorption and water solubility. Among the formulations studied, the system prepared with the CMEE-H (54) monomer presented the best results, such as the formation of a denser crosslinked matrix (although not presenting the higher degree of conversion) and highest Vickers hardness. Furthermore, the solubility and water sorption values obtained were satisfactory. For application in restorative composite resins, all the systems studied must undergo some improvements and modifications, in particular the increase in the degree of conversion values (i.e., increasing time of exposure to light source) and reducing the composite's water sorption (by adding filler particles to the system). However, this study presents viable substitutes to commercial methacrylic monomers which form polymer matrices that have equivalent or superior performance when compared to matrices formed by commercial monomers.
90

Resistência à fratura de restaurações mod

Silva, Maria Goreti 05 December 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013 / Made available in DSpace on 2013-12-06T00:23:55Z (GMT). No. of bitstreams: 1 319037.pdf: 1236930 bytes, checksum: ff79092a451f210e2f58e5aa03edfb64 (MD5) / O objetivo deste trabalho foi avaliar o efeito de dois compósitos, com diferentes matrizes poliméricas, e da técnica de fotoativação, sobre a resistência à fratura, por compressão, de pré-molares superiores com restaurações de classe II. Em 56 pré-molares superiores foram preparadas cavidades MOD, simulando tratamentos endodônticos, sendo os dentes divididos em quatro grupos (n=14) de acordo com os seguintes procedimentos: G1: fotoativação convencional, restauração com Filtek Z350XT (3M ESPE) e adesivo Adper Single Bond2 (3M ESPE); G2: fotoativação por pulso tardio, restauração com Filtek Z350XT (3M ESPE) e adesivo Adper Single Bond2 (3M ESPE); G3: fotoativação convencional, restauração com Filtek P90 (3M ESPE) e adesivo próprio da Filtek P90 (3M ESPE); e G4: fotoativação por pulso tardio, restauração com Filtek P90 (3M ESPE) e adesivo próprio da Filtek P90 (3M ESPE). No G1 e G3 (fotoativação convencional), a aplicação de compósito foi em incrementos de 2mm, sendo cada incremento fotoativado por 40 segundos, com aparelho do tipo LED, com intensidade de 500 mW/cm2, aferida com radiômetro (Demetron). No G2 e G4 (fotoativação por pulso tardio) a aplicação de compósito também foi com incrementos de 2mm, porém, sendo cada incremento fotoativado, inicialmente durante 5 segundos, com 300 mW/cm2. Após um período de 5 minutos foi realizada nova fotoativação, por 40 segundos, com intensidade de 500 mW/cm2. A fotoativação foi repetida para cada incremento. Após 24 horas, os espécimes foram polidos e submetidos ao teste de compressão, com ponta ativa com formato cilíndrico/arredondado (Instron-0,5mm/min). Os valores médios (newtons) após ANOVA2 e Teste de Tukey (p>0,05) foram: G1: 1157,98 (444,62); G2: 1404,14 (391,82); G3: 1255,30 (422,34); e G4: 1213,76 (419,95). A resistência à fratura, por compressão, dos pré-molares com restaurações MOD foi estatisticamente similar nos quatro grupos avaliados. Portanto, não foram verificadas diferenças significativas relacionadas aos dois compósitos, com diferentes matris poliméricas, e ao método de fotoativação, convencional e por pulsotardio. <br>

Page generated in 0.0523 seconds