Spelling suggestions: "subject:"resinas composta"" "subject:"tesinas composta""
351 |
Estabilidade de união à dentina com o uso de sistemas adesivos convencionais e autocondicionantes / Andrea Freire de Vasconcelos ; orientador, Sérgio VieiraVasconcelos, Andrea Freire de January 2010 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Inclui bibliografias / Proposta: Avaliar a estabilidade de união à dentina, nos períodos de 24 h, 1, 3 e 6 meses de armazenamento em água, com a utilização de sistemas adesivos convencionais e autocondicionantes. Materiais e Método: Foram utilizados 168 terceiros molares extraí / Purpose: To evaluate the stability of dentine bonds at 24 hours, and 1, 3 and 6 months of storage in water when using conventional and self-etching adhesive systems. Materials and Methods: In total, the study used 168 extracted third molars that were divi
|
352 |
Efeito do tipo de polimerização e do uso de sistemas adesivos autocondicionantes sobre a resistência de união de resinas compostas para preenchimento / Heloisa Helena Pacheco ; orientadora, Evelise Machado de SouzaPacheco, Heloisa Helena January 2012 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / Objetivo: Avaliar o efeito do tipo de polimerização e do uso de sistemas adesivos autocondicionantes sobre a resistência de união por microtração de resinas compostas de preenchimento de cura dual e química. Materiais e Métodos: Sessenta terceiros molares / Purpose: To evaluate the effect of self-etching adhesives on the icrotensile bond strength of dual- and self-cured core build-up composite resins. Materials and Methods: Sixty healthy human third molars were divided into ten groups (n=6). The mid coronal
|
353 |
Avaliação clínica retrospectiva de restaurações estéticas : classe III, IV e V / Retrospective clinical evaluation of esthetic restorations : class III, IV and VVieira, Rodrigo Monteiro January 2015 (has links)
O objetivo do presente estudo foi realizar uma avaliação clínica retrospectiva de restaurações diretas de resina composta de classe III, IV e V em dentes anteriores e pré-molares utilizando os métodos USPHS e FDI. Oitenta e sete pacientes foram selecionados através de uma pesquisa dos prontuários presentes no Setor de Acolhimento da Faculdade com restaurações realizadas entre 2000 a 2013 que possuíam um período mínimo em boca de 6 meses. Foram incluídos pacientes adultos de ambos os sexos que receberam tratamento com restaurações de classe III, IV ou V realizadas com as resinas compostas: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic e Opallis; realizadas com sistema adesivo convencional; em dentes vitais ou não vitais. Aqueles pacientes que possuíam higiene oral precária ou com necessidades especiais não foram incluídos no estudo. A avaliação clínica foi feita através dos métodos USPHS e FDI modificados por um examinador calibrado. A análise de sobrevivência das restaurações foi realizada através do método Kaplan-Meier e teste Log-Rank para comparação entre os grupos. A regressão de Cox multivariada e Hazard Ratio foram empregadas para verificar os fatores associados à falha das restaurações. O nível de significância foi de 5%. Foram avaliadas 272 restaurações, com um intervalo de tempo em boca de 8 meses até 13 anos (média - 4,8 anos). Foram avaliadas 120 restaurações classe III, entre elas, 15 apresentaram falhas (12,5%), com uma taxa de falha anual de 2,74%. Já para as restaurações de classe IV, realizou-se a avaliação de 80 restaurações, 38 demonstraram falhas (47,5%), como uma taxa de falha anual de 12,6%. E para as de classe V, foram analisadas 72 restaurações, sendo observada a presença de falhas em 27 delas (37,5%), com uma taxa de falha anual de 9,3%. O motivo mais comum de falha foi por fratura e/ou retenção para as três classes, ocorrendo em 73 casos. Dentes não vitais demonstraram 50% de falha em um tempo médio de 4,8 anos com uma taxa de falha anual de 13,4%; enquanto os dentes vitais apresentaram 28,1% de falha com uma taxa de falha anual de 6,6%. A regressão de Cox revelou associação entre marca comercial do compósito, classe da restauração e vitalidade pulpar com falha das restaurações. Conclui-se que restaurações de resina composta demonstraram um desempenho clínico satisfatório ao longo do tempo, apresentando sucesso em 70,6% dos casos em uma média de 4,8 anos, sendo que as de classe III apresentaram melhor desempenho clínico que classe V e classe IV e as restaurações em dentes desvitalizados apresentaram 2,37 vezes mais risco de falhas que restaurações em dentes vitais. Os principais motivos de falha para todos os tipos de restauração foi por fratura e/ou perda de retenção. Os dois métodos (USPHS e FDI) se demonstraram eficazes no processo de avaliação clínica em restaurações em dentes anteriores. / The aim of this study was to evaluate direct composite restorations Class III, IV, V in anterior teeth and premolars through the USPHS and FDI methods. Eighty-seven patients were selected through a search of the patients’ records present in the School of Dentistry. Restorations performed between 2000 to 2013 which a minimum of six months in mouth were selected. Adult patients of both sexes were included, who received treatment with restorations class III, IV or V with the follow composites: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic and Opallis; all restorations with total etch adhesive system; on vital and non-vital teeth. Patients with poor oral hygiene or special needs were not included in the study. Clinical evaluation was performed by USPHS and FDI modified methods, by one calibrated examiner. The survival of the restorations was analyzed using the Kaplan-Meier method and log-rank test to compare the groups, and multivariate Cox regression and hazard ratio were employed to identify factors associated with the failure of the restorations. The significance level was 5%. 272 restorations were evaluated with a time interval in service from 8 months to 13 years (mean 4.8 years). 120 class III restorations were evaluated, among them, 15 had failures (12.5%), with an annual failure rate of 2.74%. For the class IV type, 80 restorations were evaluated, 38 demonstrated failures (47.5%), with an annual failure rate of 12.6%. And for the class V, 72 restorations were analyzed, being observed the presence of failures in 27 of them (37.5%), with annual failure rate of 9.3% .The most common reason for failure was fracture or retention loss, for the three types of classes, occurring in 73 cases. Non-vital teeth showed 50% of failure in an average of 4.8 years, with an annual failure rate of 13.4%; while the vital teeth showed 28.1% of failure, with an annual failure rate of 6.6%. Cox regression revealed an association between brands, class type and tooth vitality with failures of the restorations. It was concluded that composite restorations showed a satisfactory clinical performance over time, with success in 70.6% of cases in a mean time of 4.8 years. Class III showed better clinical performance than class IV and V. Non-vital teeth restorations had 2.37 times the risk of failures than vital teeth. The main reasons for failure for all types of restoration was fracture and / or retention loss. Both methods (USPHS and FDI) demonstrated efficient in the process of clinical evaluation for anterior teeth.
|
354 |
Avaliação clínica retrospectiva de restaurações diretas e indiretas com recobrimento de cúspides / A retrospective clinical evaluation of direct and indirect restorations with cuspal replacementBerwanger, Carolina dos Santos January 2016 (has links)
Introdução: A crescente demanda por restaurações estéticas possibilitou novas escolhas de tratamento para restaurar dentes posteriores com extensa destruição coronária. Os tratamentos destes dentes podem envolver restaurações diretas com resina composta ou indiretas do tipo onlays, fabricadas com cerâmica pura ou resina composta. Porém, dados clínicos sobre a longevidade de restaurações com recobrimento de cúspides comparando as técnicas direta e indireta e os materiais resina composta e cerâmica são raros. Objetivo: Realizar uma avaliação clínica retrospectiva de restaurações diretas (resina composta) e indiretas (resina composta e cerâmica) com envolvimento de cúspides utilizando o método FDI. Metodologia: Foram avaliadas 229 restaurações em 121 pacientes (37 homens e 84 mulheres) que receberam pelo menos uma restauração direta de resina composta com recobrimento de pelo menos uma cúspide ou uma onlay de cerômero ou cerâmica entre os anos de 2003 e 2016. A avaliação visual foi feita por um examinador previamente calibrado pelo coeficiente Kappa, utilizando-se os critérios do método FDI. Os dados foram analizados através do método Kaplan-Meier, da análise de regressão de Cox multivariada e do teste Kruskal-Wallis (p <0.05). Resultados: Entre as restaurações avaliadas foram detectadas 69 falhas. As restaurações obtiveram uma taxa de sucesso de 69,9%, com taxa anual de falha (AFR) de 8,0%. Restaurações diretas de resina composta apresentaram 34,1% de falha, com AFR de 9,6%. Onlays em cerômero apresentaram 27,3% de falha, com AFR de 7,1%. Onlays de cerâmica apresentaram 28,8% de falha com AFR de 7,6%. Restaurações em homens falharam mais do que em mulheres. A causa mais comum de falha foi fratura e retenção, ocorrendo em 48 casos (69,56% das falhas). Conclusão: Restaurações diretas de resina composta e indiretas de cerômero ou cerâmica demonstraram longevidade semelhante, independente do número de cúspides envolvidas. Restaurações indiretas tiveram menor índice de falha anual do que restaurações diretas, apresentando melhor desempenho na avaliação qualitativa. Pacientes mulheres apresentaram menor prevalência e menor risco de falha de restaurações do que pacientes do sexo masculino. / Introduction: The increasing demand for aesthetic restorations had enabled new treatment choices to restore posterior teeth with extensive coronary destruction. The treatments of these teeth involve direct composite restoration or indirect onlays, made with ceramic or composite. However, clinical data on the longevity of cuspal restorations comparing direct or indirect techniques and the materials are rare. Objective: To perform a retrospective clinical evaluation of direct restorations (composite resin) and indirect restorations (composite resin and ceramics) with cuspal involvement using the FDI criteria. Methodology: 229 restorations were evaluated in 121 patients (37 men and 84 women) who received at least one direct composite restoration with envolvement of at least one cusp or ceramic and composite onlays among the years 2003 and 2016. The visual evaluation was done by an examiner previous calibrated by the Kappa coefficient, using the FDI criteria. Data were analyzed by the Kaplan-Meier method, multivariated Cox regression analysis and Kruskal-Wallis test (p<0.05). Results: Among the evaluated restorations, 69 failures were detected. Restorations achieved a survival rate of 69.9%, with annual failure rate (AFR) of 8.0%. Direct composite restorations presented a 34.1% failure, with AFR of 9.6%. Composite onlays presented 27.3% of failure, with AFR of 7.1%. Ceramic onlays showed a 28.8% failure rate with AFR of 7.6%. Restorations in men have failed more than in women. The most common reason for failure was fracture of the material and retention, occuring in 48 cases (69.56% of failures). Conclusion: Direct and indirect restorations showed similar longevity, regardless of the number of cusps involved. Indirect restorations had lower annual failure rate than direct restorations, presenting better performance in the qualitative analisys. Female patients presented lower prevalence and lower risk of failure of restorations than male.
|
355 |
Avaliação quantitativa e qualitativa da rugosidade superficial de resinas compostas com nanopartículas submetidas a diferentes métodos de polimentoCosta, Catharina Simoni da January 2013 (has links)
Introdução: Existe no mercado odontológico muitos instrumentos rotatórios para serem utilizados no polimento final de uma restauração adesiva. Como são muitas as opções, e um mesmo fabricante tem mais de um tipo de instrumento rotatório para realizar a finalização da restauração, não se estabelece uma conduta única que determine qual o instrumento utilizar para resinas compostas que contenham nanopartículas. Objetivo: Avaliar, in vitro, o efeito de dois diferentes sistemas de polimento, baseados em um e multi etapas, sobre a qualidade e rugosidade da superfície de duas resinas com nanopartículas. Materiais e métodos: As amostras foram confeccionadas com resina nanoparticulada Filtek Z 350 XT (3M ESPE) e nanohíbrida Tetric N Ceran (Ivoclar Vivadent ). As amostras foram confeccionadas em moldes cilíndricos medindo 3 mm X 6 mm. Um único operador executou todos os procedimentos. Cada grupo foi composto por 20 amostras: 1) ZXT-Controle (sem polimento); 2)TNC-Controle (sem polimento); 3) ZXT+ Sof-Lex (seqüência Laranja – fina e superfina); 4) ZXT+ Optrapol; 5) TNC+ Optrapol ; 6) TNC+ Sof- Lex (seqüência Laranja – fina e superfina ). A rugosidade de superfície foi avaliada com rugosímetro (Ra), MEV e AFM. Estatística: Para análise das médias de rugosidade Ra (μm), os dados foram submetidos aos testes de normalidade de ANOVA, ao nível de significância de 5%. Uma vez verificada a distribuição normal dos resultados, estes foram submetidos à análise de variância, seguida pelo teste de Tukey com nível de significância de 5%. Resultados: As análises qualitativas e quantitativas mostraram que as resinas polidas com Optrapol apresentaram maior rugosidade superficial e o polimento com Sof-Lex não mostrou diferença estatística entre as resinas testadas. A menor rugosidade foi obtida com os grupos controle, sem diferença estatística entre as resinas. Conclusão: Optrapol promove maior rugosidade nas resinas testadas, e ZXT apresentou maior rugosidade. O polimento com Soft-Lex não mostrou diferenças estatisticamente significantes entre as resinas testadas. A rugosidade superficial das resinas foi menor com TNC, quando comparado com Optrapol. A menor rugosidade de superfície obtida foi pelo grupo controle. / Introduction: There are many tools on the market dental rotary for use in polishing of a restoration adhesive. As there are many choices, and the same manufacturer have more than one type of rotary apparatus of restoration, does not establish a single conduit to determine which tool to use composites containing nanoparticles. Objective: To evaluate, in vitro, the effect of two different polishing systems, based on a multi steps and on the quality and surface roughness of two composites nanoparticles. Materials and methods: The samples were prepared with nanofilled material resin Filtek Z 350 XT (3M ESPE) and nanohíbrid Tetric N Ceran (Ivoclar Vivadent). The samples were made in cylindrical molds measuring 3 mm X 6 mm. A single operator executed all procedures. Each group consisted of 20 samples: 1) ZXT-control (without polishing); TNC-2) control (without polishing); 3) ZXT Sof-Lex (Orange – fine and Superfine); 4) ZXT Optrapol; 5) TNC Optrapol; 6) TNC Sof-Lex (Orange – fine and Superfine). The surface roughness was assessed with porfilometry (Ra), SEM and AFM. Statistical analyses: For analysis of mean roughness Ra (um), the data were tested for normality of ANOVA, at a significance level of 5%. Once verified the normal distribution of the results, they were subjected to analysis of variance followed by Tukey's test with a significance level of 5%. Results: The qualitative and quantitative analyzes showed that resins polished with Optrapol showed higher surface roughness and polishing with Sof-Lex showed no statistical difference between the resins tested. The lowest roughness was obtained with the control group, with no statistical difference between the resins. Conclusion: Optrapol promotes greater roughness in the resins tested, and ZXT showed higher roughness. Polishing with Soft-Lex showed no statistically significant differences between the tested resins. The surface roughness of the resins with TNC was lower when compared with Optrapol. The lowest surface roughness was obtained by the control group.
|
356 |
Avaliação da estabilidade de cor e sorção de compósitos fotoativados por luz halógena e por emissão de diodo em diferentes meios de imersão / Avaliação da estabilidade de cor e sorção de compósitos fotoativados por luz halógena e por emissão de diodo em diferentes meios de imersão / Evaluation of color stability and sorption of resin composites light-cured by halogen lamp and LED in different mediums of immersion / Evaluation of color stability and sorption of resin composites light-cured by halogen lamp and LED in different mediums of immersionRodrigo Prada Sant'Anna Guimarães 07 February 2006 (has links)
A demanda por restaurações estéticas tem aumentado consideravelmente nos últimos anos. Os materiais restauradores estéticos diretos, assim como novas fontes luminosas para sua ativação, têm sido cada vez mais utilizadas e vêm passando por uma série de modificações estruturais buscando a obtenção de melhores propriedades mecânicas e ópticas. Desta maneira, o presente estudo teve por objetivo avaliar a estabilidade de cor e sorção de compósitos fotoativados por luz halógena e por emissão de diodo em diferentes meios de imersão. Para isso, 120 corpos de prova utilizando os compósitos resinosos TPH Spectrum (Dentsply), Esthet-X (Dentsply) na cor A2 utilizando uma matriz de teflon e aço inox, ativadas por 03 fontes luminosas distintas (Fotopolimerizador de luz halógena QHL 75 Curing Lite, Dentsply; Fotopolimerizador de luz de diodo BIOLUX Standart II, Bio-Art e Fotopolimerizador de luz de diodo Smart Lite PS, Dentsply). Após todos corpos de prova terem sido submetidos à seqüência de acabamento, polimento, limpeza, pesagem inicial e leitura inicial de cor em um espectrofotômetro de reflectância foram armazenados por 07 dias a 37o C em água destilada (grupo da água destilada), café (grupo do café), coca-cola (grupo da coca-cola) e vinho tinto (grupo do vinho tinto). Completado o tempo de imersão os corpos de prova foram novamente lavados, pesados e levados ao espectrofotômetro para leitura final de cor. Após obtenção dos resultados finais de cor e peso foi calculada a estabilidade de cor e sorção de cada corpo de prova sendo posteriormente submetidos a tratamento estatístico (ANOVA e teste de Bonferroni com 5% de significância para estabilidade de cor e teste de Kruskal-Wallis com 5% de significância para sorção). Baseado nos resultados obtidos pode-se concluir existir diferença de estabilidade de cor a ponto de ser clinicamente perceptível em compósitos fotoativados por luz halógena e luz de diodo em diferentes meios de imersão. Os meios que mais provocaram alterações cromáticas em ordem decrescente, respectivamente, foram: vinho tinto, coca-cola, café e água destilada. Os corpos-de-prova fotoativados pelo aparelho BIOLUX Standart II apresentaram uma menor estabilidade de cor quando comparados com os demais. Ambos compósitos Esthet-X e TPH Spectrum mostraram acentuadas alterações cromáticas quando imersos em vinho tinto e coca-cola. O TPH Spectrum mostrou-se mais estável frente às alterações cromáticas. Para o experimento de sorção concluímos não haver diferença estatística. / The demand of aesthetics restorations has been considerable increased last years. The direct esthetic restorative materials and new kinds of light sources have been passing by innumerous structural modifications to obtain better optical and mechanical properties. The purpose of this study was to evaluate the color stability and sorption of resin composites light-cured by quartz-tungsten-halogen lamps and light-emitting diodes in different mediums of immersion. One hundred and twenty specimens using TPH Spectrum (Dentsply), Esthet-X (Dentsply) shade A2 were constructed by using a teflon and iron inoxidizable matrix light-cured by 03 distincts light sources (conventional halogen lamp light curing unit â QHL 75 Curing Lite, Dentsply; light emitting diode curing unit â BIOLUX Standart II, Bio-Art and light emitting diode curing unit â Smart Lite PS, Dentsply). All the specimens passed by procedures of finishing, polishing and initial weight and color measurements were done. After the color measurements done using a reflectance spectrophotometer the specimens were immersed for 07 days at 37o C in destiled water (destiled water group), coffee (coffee group), coke-cola (coke-cola group) and red wine (red wine group). Completed the immersion times the specimens were cleansed and final measurements of weigh and color were done. The percentage of sorption and the color stability were calculated and the values were submitted to statistic treatment (ANOVA and Bonferroni`s test with 5% of significance for color stability and Kruskal-Wallis`s test with 5% of significance for sorption). Based on the results of the study the authors concluded that existed difference of color stability clinically perceptible in composites light-cured by quartz-tungsten-halogen lamps and light-emitting diodes in different mediums of immersion. Red wine, coke-cola, coffee and destiled water, in order, showed the biggest values of discoloration. The specimens light-cured by BIOLUX Standart II unit showed lowest color stability than the others specimens. Esthet-X and TPH Spectrum showed high values of discoloration when they were immersed in red wine and coke-cola. TPH Spectrum showed more stable front of discolorations. To sorption experiment the authors concluded that there was no statistic difference.
|
357 |
Avaliação da efetividade da fotoativação de dois materiais resinosos com diferentes fontes de luz, por meio da microdureza Knoop, resistência à compressão, resistência flexural e caracterização dos materiais / Evaluation of the effect of the light source on the photo polymerization of two resin material by the Knoop microhardness, compressive strength, flexural strength and material characterizationCecy Martins Silva 15 September 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
|
358 |
Avaliação da influência de um gel a base de peróxido de hidrogênio a 35% sobre a rugosidade superficial de três resinas compostas fotopolimerizáveis de diferentes tamanhos médios de partículas / Evaluation of influence of a gel-based hydrogen peroxide 35% on the surface roughness of three composite resins of different sizes of particlesAndré Fábio Vasconcelos Moro 19 December 2007 (has links)
O clareamento dental se firmou na odontologia como o meio disponível mais simples, comum e conservador de devolver o padrão de cor almejado pelos pacientes. O processo clareador consiste em um ataque a superfície do substrato dentário, provocando pequenas alterações através da quebra de pigmentos, que são longas cadeias de carbono, originando cadeias moleculares cada vez menores até que possam ser eliminadas por difusão. Considerando-se a prática clínica diária nota-se que, algumas vezes, o agente clareador entra em contato com materiais restauradores que ali se encontram, como as resinas compostas por exemplo. Tal procedimento pode ocasionar a indicação de substituição da resina em boas condições clínicas, devido à diferença de cor entre o dente clareado e o compósito. Porém, há casos, como por exemplos: restaurações posteriores e manutenção de clareamento, em que a cor não seria fator decisivo para uma intervenção clínica sobre a restauração. Este estudo avaliou, através de microscopia de força atômica, o efeito de um protocolo de clareamento dentário de consultório a base de peróxido de hidrogênio 35% sobre a rugosidade superficial de três resinas de tamanhos de partículas diferentes (micro-híbrida, microparticulada e nanoparticulada). Vinte e quatro imagens de 5 X 5μm selecionadas aleatoriamente e geradas por microscopia de força atômica foram analisadas estatisticamente por ANOVA e pelo teste SNK (p< 0,05). A análise das topografias demonstrou a resina microparticulada com a menor rugosidade inicial (Rq: 19,22μm e Ra: 14,95μm) e final (Rq: 28,66μm e Ra: 23,06μm), sendo a final semelhante estatisticamente a nanoparticulada inicial (Rq: 29,60μm e Ra: 23,75μm). Seguiram a micro-híbrida inicial (Rq: 35,45μm e Ra: 26,22μm) e a nanoparticulada final (Rq: 40,22μm e Ra: 31,49μm). A resina micro-híbrida final apresentou a maior rugosidade (Rq: 47,41μm e Ra: 36,45μm). Um aumento uniforme e proporcional da rugosidade de superfície nas três resinas testadas foi constatado. Em uma segunda etapa do estudo, a mesma área de superfície foi avaliada antes e depois do procedimento simulador de clareamento e o resultado foi semelhante, porém com a visualização das localidades afetadas. / The bleaching has been in dentistry as the simplest, common and conservative way to return of the pattern of color desired by the patients. The bleaching consists in an attack on dental surface breaking pigments, which are long chains of carbon, causing molecular chains ever smaller until it can be eliminated by diffusion. Considering the practice daily, the bleaching agent contacts restorative materials, such as composite resins for example. This procedure can appoint the replacement of the resin in good clinical conditions due the difference in color between the cleared tooth and composite. But there are cases, for examples: posterior restoratives and maintenance of bleaching, in which color would not be decisive factor for a clinical intervention on the restoration. This study evaluated, through atomic force microscopy, the effect of a memorandum of an in office dental bleaching by hydrogen peroxide 35% on the surface roughness of three types of resins of different sizes of particles (micro-hybrid, microparticles and nanoparticles). Twenty four images of 5 X 5μm randomly selected and generated by atomic force microscopy, were statistically analyzed by ANOVA and the SNK test (p< 0.05). The analysis of topographies showed the microfilled resin with lower initial roughness (Rq: 19.22μm and Ra: 14.95μm) and final roughness (Rq: 28.66μm and Ra: 23.06μm), with the final roughness statistically similar to initial roughness of nanoparticles resin (Rq: 29.60 μm and Ra: 23.75μm). Followed the initial roughness of micro-hybrid resin (Rq: 35.45 μm and Ra: 26.22 μm) and the final roughness of nanoparticles resin (Rq: 40.22μm e Ra: 31.49μm). The final roughness of micro-hybrid resin had the highest roughness (Rq: 47.41 μm and Ra: 36.45 μm). An uniform and proportional increase of surface roughness of the three resins tested was found. A second stage of the study evaluated the same area of surface before and after the procedure simulator of bleaching and the result was the same, with the view of the affected localities.
|
359 |
Avaliação do efeito de diferentes agentes clareadores na rugosidade superficial e estabilidade de cor de dois compósitos / In vitro evaluation of different bleaching agents on the roughness and color stability of two dental compositesAnna Paula Kalix França Mendes 13 February 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar, in vitro, o efeito de dois clareadores a base de peróxido de hidrogênio a 10% e a 35%, Rembrandt Whitening Pen/Oral B e Whiteness HP Maxx/FGM na estabilidade de cor e rugosidade superficial de dois compósitos, sendo um nanohíbrido TPH3/ Dentsply e outro nanoparticulado Filtek Z350/3M ESPE. Foram confeccionados 40 corpos de prova a partir de uma matriz de aço inox com dimensões de 21,0 mm de diâmetro e 2,00 mm de profundidade e divididos em dois grupos conforme o compósito a ser avaliado e submetidos aos seguintes experimentos: Exp. I Ação dos agentes clareadores na estabilidade de cor dos compósitos; Exp. II - Ação dos agentes clareadores na rugosidade superficial dos compósitos; Exp. III - Ação do polimento de superfície na rugosidade superficial e retomada de cor dos compósitos. Tanto a rugosidade como a estabilidade de cor foi avaliada em rugosímetro Mitutoyo SJ 201P e Espectofotômetro de Reflectância Perkin Elmer Lambda 35 UV/VIS respectivamente durante as seguintes etapas do experimento: T0 - após a confecção dos corpos de prova, T1 - após envelhecimento acelerado das amostras por 24 horas por luz ultravioleta, T2 - após submetidas a dois corantes: café e açaí por 7 dias, T3 - após submetidas aos agentes clareadores e T4- após polimento das mesmas. Durante todo o experimento os corpos de prova foram mantidos em saliva artificial e estufa calibrada a 37oC. Os resultados foram tratados estatisticamente por ANOVA e testes de Tukey, comparações múltiplas de Bonferroni e SNK com 5% de significância. Não foram observadas diferenças estatisticamente significantes entre os corantes, o mesmo acontecendo quando os clareadores foram comparados por Teste-t de Student com 5% de significância. Baseado nos resultados obtidos pôde-se concluir que o compósito TPH3 foi mais afetado pelos corantes que o compósito Z350. Os agentes clareadores não foram capazes de promover clareamento dos compósitos nos tempos testados, porém o polimento possibilitou retorno à condição de cor inicial (envelhecida) para o compósito TPH3 o mesmo não acontecendo para o Z350. O polimento não determinou retorno à condição original de rugosidade para qualquer dos compósitos. / The objective of this study was to evaluate, in vitro, the effects of two commercially available bleaching agents containing hydrogen peroxide, Rembrandt Whitening Pen/Oral B and Whiteness HP Maxx/FGM, on the surface roughness and on color change of two composites (TPH3/Dentsply and Filtek Z350/3M ESPE). Twenty specimens of each material were constructed by using a stainless matrix, measuring 21.0 mm diameter and 2.00 mm depth and divided in three groups according the experiments. Group I- effect of the bleaching agents on the composites color change; Group II- effect of the bleaching agents on surface roughness; Group III- effect of polishing procedures on the surface roughness and on color change of the composites. The color measurements were done using a reflectance spectrophotometer Perkin Elmer Lambda 35 UV/VIS according to the CIE L*a*b* color scale and the roughness measurements were obtained using a digital Mitutoyo rugosimeter SJ 201P. The measurements were made in five times: T0: after the specimen preparation; T1: after accelerated aging for 24 hours UV light; T2: after immersed for 07 days at 37o C in either coffee or açaí (a typical fruit of North of Brazil); T3: after bleaching procedures and T4: after finishing and polishing. The results were statistical treated by ANOVA and the differences treated by Tukey, Bonferroni`s test and SNK with 5% of significance. According t-Test with 5% of significance, there were no differences between the staining (coffee and açaí) and neither between the bleaching agents tested. The composite TPH3 showed higher values of discoloration when compared with Filtek Z350, The bleaching agents were not able to improve any kind of whitening on the composites surface. The polishing procedures after bleaching were effective on return the TPH3 to its original color, but they were not capable to return the original roughness of both of the composites.
|
360 |
Influência da variação da intensidade de luz, para uma mesma exposição radiante, no comportamento mecânico de uma resina convencional e de uma resina de baixa contração / Influence of photoactivation modes, with the same radiant exposure, on mechanical properties of a convencional and a low-shrinkage compositeMariana Rodrigues Gonzalez 08 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo avaliar a influência da variação da intensidade de luz, para uma mesma exposição radiante, na resistência à flexão, na microdureza e na resistência à tração diametral de uma resina convencional e de uma resina de baixa contração. Para a confecção dos corpos de prova foram utilizadas as resinas Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) fotoativadas por meio dos seguintes protocolos: Convencional (400mW/cm por 60 s), Média intensidade (700mW/cm por 34 s) e Alta intensidade (950mW/cm por 26 s). Todos os corpos de prova receberam a mesma exposição radiante de 24J/cm. A resistência à flexão foi avaliada por meio do ensaio de flexão três pontos. Para este ensaio foram confeccionados trinta corpos de prova de cada material (n=10) com dimensões de 10mm x 2mm x 1mm. A avaliação da microdureza Knoop foi obtida a partir de seis discos de cada resina com 5mm de diâmetro por 2mm de espessura (n=2), sendo realizadas cinco indentações em cada espécime. Trinta corpos de prova cílindricos de cada compósito (n=10) com 3mm de diâmetro por 6mm de altura foram confeccionados para a realização do teste de tração diametral. A análise estatística dos resultados obtidos foi realizada por meio do teste de análise de variância (ANOVA) e do teste de múltiplas comparações de Tukey (p < 0.05). A resistência à flexão da resina P90 não foi influenciada de forma significativa pelas diferentes formas de ativação, enquanto a Z250 obteve resultados significantemente maiores para o protocolo de alta intensidade em relação ao convencional. Em todas as intensidades de luz, os resultados da Z250 foram significativamente maiores que os da P90. A microdureza da resina P90 foi estatisticamente maior para o grupo de média intensidade em relação aos outros, já a Z250 não obteve resultados com diferença estatística em relação às formas de ativação. Para a mesma irradiância, a Z250 obteve maiores valores de microdureza do que a P90, com exceção para o protocolo de média intensidade em que não houve diferença estatística entre os materiais. Os valores de resistência à tração não foram influenciados de forma significativa nem pelas diferentes intensidades de luz, nem pelos materiais utilizados. A influência da variação da intensidade de luz depende do tipo de compósito utilizado e da propriedade mecânica avaliada. / This study has the purpose of evaluating the variation of the intensity of light, for a constant radiation exposure, for flexural strength, for microhardness, and for tensile strength, of a conventional composite and a low shrinkage composite. The test samples were made of Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) light-activated composites. The following light activating protocol was used: conventional (400mW/cm for 60 s); medium intensity (700mW/cm for 34 s), and high intensity (950mW/cm for 26 s). All of the test samples received the same radiation exposure of 24J/cm. The flexural strength was measured through the three-point bending test. For this test, thirty especimens were made for each material (n=10), measuring 10mm x 2mm x 1mm. The Knoop hardness evaluation was carried out using six discs of each composite measuring 5mm in diameter, and 2mm in height (n=2), with five indentations in each specimen. Thirty cylindrical test samples of each composite (n=10) measuring 3mm in diameter, and 6mm in height were obtained for the diametral tensile test. The statistical analysis of the results was carried out through analysis of variance test (ANOVA) and through Tukeys multiple comparisons test (p < 0.05). The P90 composite flexural strength was not significantly influenced by the different activating methods, while Z250 achieved significantly higher values for the high intensity protocol when compared to the conventional one. For all light intensities, the Z250 results were higher than those for P90. P90's microhardness was statistically higher for the medium intensity group when compared to the others, whereas Z250's results had no statistical difference for the different activating protocols. For the same irradiation, Z250 presented higher values for microhardness than P90, except for the medium intensity protocol, which had no statistical difference between the different materials. The tensile strength values were not significantly influenced neither by the different light intensities, nor by the materials. The influence of the variation of light intensity depends upon the type of composite, as well as the mechanical property to be evaluated.
|
Page generated in 0.1122 seconds