• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Propriedades antibacterianas, físicas e mecânicas de uma resina composta modificada com nanopartículas de ZnO e TiO2, puras e decoradas com prata, obtidas por diferentes sínteses /

Dias, Hércules Bezerra. January 2017 (has links)
Orientador: Alessandra Nara de Souza Rastelli / Resumo: Estudos recentes relatam que resinas compostas contendo nanopartículas (NPs) de óxidos metálicos, tais como óxido de zinco (ZnO) e dióxido de titânio (TiO2) têm potencial antibacteriano e podem controlar a formação do biofilme oral cariogênico. O objetivo desse estudo foi avaliar a capacidade antibacteriana de uma resina composta modificada por NPs de óxido de zinco e dióxido de titânio puras e decoradas com prata (ZnO, ZnO/Ag, TiO2 e TiO2/Ag), bem como, avaliar as propriedades de resistência à compressão e à tensão diametral, estabilidade de cor, rugosidade superficial e grau de conversão após modificação da resina composta com as NPs. As NPs foram sintetizadas pelos métodos dos precursores poliméricos e hidrotermal assistido por micro-ondas, e caracterizadas por DRX, área de superfície BET, FTIR e MET. A resina FiltekTM Z350XT modificada com 0,5; 1 e 2% (em massa) foi testada sobre Streptococcus mutans por meio do teste do contato direto (UFC/mL) para determinação da menor concentração inibitória e então avaliada em biofilme de 7 dias por meio decontagem das unidades formadoras de colônias (UFC/mL). As resistências à compressão e à tração diametral da resina composta modificada (n=40) foram avaliadas utilizando-se máquina de ensaio universal (EMIC). O grau de conversão (n=25) foi realizado por análise em FTIR e a leitura da rugosidade superficial (n=50) foi realizada utilizando-se rugosímetro portátil. A estabilidade de cor (n=180) foi avaliada por leitura espectrofotométri... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Different methods to inhibit biofilm formation on dental restorative materials have been studied for decades and recent studies report that composite resins containing metal oxide nanoparticles (NPs), such as zinc oxide (ZnO) and titanium dioxide (TiO2), have antibacterial potential and can control the formation of cariogenic oral biofilm. In this way, the purpose of this study was to evaluate the antibacterial capacity of a resin modified by pure and silver decorated ZnO and TiO2 (ZnO, ZnO/Ag, TiO2 and TiO2/Ag) NPs and to evaluate the compressive and diametral tensile strength, color stability, surface roughness and degree of conversion after modification of the composite resin with the NPs. The NPs were synthesized by polymeric precursor and microwave-assisted hydrothermal methods, characterized by XRD, BET surface area, FTIR and MET. The direct contact test with Filtek ™ Z350XT modified with 0.5; 1 and 2% (by mass) of NPs against Streptococcus mutans was performed in order to choose the minor concentration to perform the other tests. The modified resin was tested against the 7- days S. mutans biofilm. The compressive strength and diametral tensile strength of the modified composite resin (n = 40) was tested using a universal test machine (EMIC). The degree of conversion (n = 25) was performed by FTIR analysis and the surface roughness reading (n = 50) was performed using a portable surface roughness tester. The color stability (n=180) was evaluated by spectrophotometric readings after storage in coffee solution and artificial saliva. The data was analyzed using the software IBM SPSS Statistics 20.0 (SPSS Inc. Chicago, USA). One-way ANOVA were performed to antibacterial and mechanical tests data, two-way ANOVA for degree of conversion and a mixed model repeated measurements ANOVA and a post hoc test for repeated measures with adjustment... (Complete abstract electronic access below) / Doutor
342

Avaliação clínica longitudinal de restaurações de resina composta em lesôes cervicais não cariosas utilizando as técnicas direta e semidireta : estudo randomizado /

Elia, Laura Célia Fernandes Meirelles. January 2018 (has links)
Orientador: Eduardo Bresciani / Coorientadora: Taciana Marco Ferraz Caneppele / Banca: Maria Filomena Rocha Lima Huhtala / Banca: Graziela Ribeiro Batista / Banca: Clovis Pagani / Banca: Rayssa Ferreira Zanatta / Resumo: O objetivo desse estudo clínico randomizado boca dividida foi avaliar longitudinalmente a efetividade de restaurações de resina composta de lesões cervicais não cariosas realizadas pelas técnicas direta e semidireta. Foram selecionados 30 pacientes voluntários com necessidade de restaurações cervicais do tipo classe V. Cada paciente recebeu duas restaurações, uma realizada pela técnica direta e outra através da técnica semidireta, totalizando 60 restaurações. Após a realização das restaurações, foi feita uma avaliação inicial imediata (baseline), após 7 dias, 6, 12 e 24 meses, por meio dos critérios USPHS modificado. Cada paciente foi avaliado a cada retorno por dois examinadores calibrados. A análise dos dados foi realizada através de estatística descritiva por meio de porcentagem de sucesso das restaurações de acordo com os critérios estudados e os escores obtidos. Para análise inferencial foi realizado o teste T Student para avaliar as diferenças entre extensão, profundidade e tempo. Os testes Qui-Quadrado/Fisher foram utilizados para comparação das taxas entre os grupos após cada período (p<0,05). Os resultados obtidos foram avaliados por testes de sobrevida e taxa anual de falha (Kaplan-Meier). Em relação ao tempo, foi observada diferença estatisticamente significante, sendo a técnica direta 21,8 min (± 14,50) mais rápida que a técnica semi direta 35,3 min (± 19,89). Das 60 restaurações realizadas, 1 restauração direta foi perdida por falha de retenção e nenhum paciente ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this randomized split-mouth clinical study was to longitudinally evaluate the effectiveness of composite resin restorations of non-carious cervical lesions performed by direct and semi-direct techniques. A total of 30 volunteers with a need for class V cervical restorations were selected. Each patient received two restorations, one performed by the direct technique and the other by the directindirect technique, totaling 60 restorations. Assessment at baseline, 7 days, 6, 12 and 24 months, we performed using the modified USPHS criteria. Each patient was evaluated at return by two calibrated examiners. Data analysis was performed through descriptive statistics analysis using percentage of success of the restorations according to the criteria studied and scores obtained. For inferential analysis, the Student T test was used to evaluate the differences between extension, depth and time. Chi-Square/Fisher tests were used to compare rates between groups after each period (p <0.05). The results were evaluated by survival and annual failure rates (Kaplan-Meier). Differences were detected regarding to time, in which direct and direct-indirect procedures last 21.8(± 14.50) and 35.3 (± 19.89) minutes, respectively. Of the 60 restorations performed, 1 direct restoration was lost due to retention failure and no patient was missing the return in 7 days. At 6 months, 4 restorations were lost due to lack of retention in the direct technique and 5 restorations were lost for the... (Complete abstract click electronic access below) / Doutor
343

Viabilidade técnica da produção de compósitos fibra-polímero à base de resíduos /

Pupo, Humberto Fabrizzi de Figueiredo, 1982. January 2017 (has links)
Orientador: Alcides Lopes Leão / Coorientador: Adriano Wagner Ballarin / Banca: Holmer Savastano Junior / Banca: Silvia Regina Lucas de Souza / Banca: Derval dos Santos Rosa / Banca: Carla dos Santos Riccardi / Resumo: A utilização dos resíduos sólidos como matéria-prima pode diminuir consideravelmente a extração de recursos naturais, diminuindo assim o impacto sobre o meio ambiente. Dentre os resíduos, os plásticos estão entre os que mais apresentam problemas, pois, mesmo quando descartados corretamente nos aterros sanitários, causam danos ao formarem uma camada impermeável que dificulta a compactação do lixo, afetando as trocas de líquidos e gases gerados e reduzindo a eficiência do processo de biodegradação da matéria orgânica. Diante dos problemas, este trabalho teve por objetivos avaliar a viabilidade técnica de utilização de dois tipos de processos: a extrusora dupla rosca e o misturador termocinético (Drais), na produção de compósitos de BOPP (Polipropileno Biorientado metalizado), reforçados com resíduos de cascas, de eucalipto (CE) e de arroz (CA). Das misturas entre esses resíduos, foram confeccionados 10 tratamentos, de onde se extraíram os corpos de provas, moldados por injeção. Foram avaliadas as propriedades mecânicas (flexão - módulo de ruptura-MOR e módulo de elasticidade-MOE, resistência à tração, resistência ao impacto e dureza Shore D), térmicas (avaliação da condutividade térmica e isolamento térmico), termomecânica (temperatura de deflexão sob aquecimento-HDT) e morfológica, com microscópio estéreo e aumento de 50 vezes para analisar a estrutura interna do corpo de prova, depois de fraturado pelo ensaio de impacto. Para análise das propriedades mecânicas dos corpos de p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of solid waste as raw material can considerably reduce the extraction of natural resources, thus reducing the impact on the environment. Among residues, plastics are among the most problematic ones because, even when they are properly disposed in landfills, they cause damage by forming a barrier layer which makes it difficult to compact the garbage, affecting the exchange of generated liquids and gases, reducing the efficiency of the biodegradation process of the organic matter. Before such problems, the objective of this work was to evaluate the technical feasibility of two types of processes, the double screw extruder and the thermokinetic mixer - dryser, in the production of BOPP (Bioriented metallized Polypropylene) composites, strengthened by residues of barks eucalyptus (CE) and rice (CA). From the mixtures among these residues 10 treatments have been prepared, from where the test bodies were extracted, molded by injection. Mechanical properties (flexurerupture modulus-MOR and elasticity modulus-MOE, tensile strength and impact strength towards Shore D hardness), as well as thermal (thermal conductivity and thermal insulation evaluation), thermo-mechanical (heat deflexion temperature-HDT) and morphological characteristics have been evaluated by using a stereo microscope and 50x magnification to analyze the internal structure of the test body, after being fractured by the impact test. For analyzing the mechanical properties of the proof bodies the standards ASTM ... (Complete abstract click electronic access below) / Doutor
344

Grau de conversão de um compósito restaurador pré-aquecido, empregado como agente de cimentação

Melo, Tiago Spezia de 26 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T00:38:33Z (GMT). No. of bitstreams: 1 292964.pdf: 33759733 bytes, checksum: d45eb72ca14a67872f3bc246192ed411 (MD5) / O objetivo deste trabalho foi avaliar o grau de conversão de um compósito restaurador micro-híbrido pré-aquecido, fotoativado por três combinações de intensidade de luz e tempo de exposição, através de pastilhas cerâmicas com dois diferentes graus de translucidez e quatro espessuras. As pastilhas cerâmicas foram obtidas a partir do seccionamento de blocos IPS Empress CAD HT (alta translucidez) e LT (baixa translucidez), nas espessuras de 1mm, 2mm, 4mm e 6mm. Três combinações de intensidade de luz e tempo de exposição foram testadas: LED60 (aparelho LED a 1200mW/cm2 por 60s), VIP60 (aparelho halógeno a 600mW/cm2 por 60s) e VIP120 (aparelho halógeno a 600mW/cm2 por 120 segundos). A partir do cruzamento das três variáveis, foram obtidos 24 grupos. Outros três grupos foram incluídos, nos quais a fotoativação foi realizada sem a interposição de uma pastilha cerâmica. Para confecção das amostras, o compósito Z100 foi aquecido a 68°C e inserido em uma matriz circular, com 6mm de diâmetro e 0,4mm de profundidade. Dependendo do grupo, a fotoativação foi realizada diretamente sobre o material ou através de um dos blocos cerâmicos. Os discos de compósito foram armazenados por 24h e processados para avaliação por espectroscopia no infravermelho por transformada de Fourier (FTIR), a fim de determinar o grau de conversão do material. Os resultados da análise estatística revelaram diferenças significantes em todas as variáveis independentes (translucidez da cerâmica, espessura da cerâmica, protocolo de fotoativação) e na interação entre cerâmica e espessura. Conclui-se que o uso de compósitos restauradores pré-aquecidos é um procedimento viável, desde que respeitadas as interações entre a translucidez e a espessura do material (i.e., até 4mm com cerâmicas de baixa translucidez e até 6mm com cerâmicas de alta translucidez).
345

Avaliação da resistência à fadiga e do modo de fratura de restaurações adesivas implantossuportadas em cerâmica e resina composta sobre pilares personalizados de zircônia para região de pré-molares

Oderich, Elisa 26 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T02:30:42Z (GMT). No. of bitstreams: 1 292742.pdf: 13451791 bytes, checksum: 015587f95c41433389f1ce0c361c5173 (MD5) / Esse estudo avaliou a resistência à fadiga e o modo de fratura de restaurações adesivas implantossuportadas confeccionadas de cerâmica e resina composta sobre pilares personalizados de zircônia para região de pré-molares com dois designs distintos, para coroas e onlays. Foram obtidos 60 pilares personalizados apresentando dois preparos distintos (coroa ou onlay). As restaurações correspondentes foram fabricadas pelo sistema CAD/CAM (Cerec 3) em cerâmica (Paradigm C) ou resina composta (Paradigm MZ100) totabilizando 4 grupos experimentais, n=15. As superfícies adesivas dos pilares foram jateadas com Al2O3. As superfícies internas das restaurações foram condicionadas com ácido hidrofluorídrico e silanizadas (Paradigm C) ou jateadas e silanizadas (Paradigm MZ100). O protocolo adesivo após o aparafusamento do pilar sobre o implante (Titamax CM) constava no uso de primer para zircônia (Z-Prime Plus), adesivo (Optibond FL) e resina composta fotopolimerizável pré-aquecida (Filtek Z100). Foi simulado o movimento mastigatório cíclico e isométrico (5Hz) com carga de 50N (5000x), seguido dos ciclos de 200N, 400N, 600N, 800N, 1000N, 1200N e 1400N (25.000x). Cada espécime foi carregado até fraturar ou até máximo de 180.000 ciclos. Os 4 grupos foram comparados usando a análise da curva sobrevivência (Teste de Logrank a P=0,05). Todas as onlays e coroas de resina composta sobreviveram (índice de sobrevivência de 100%), enquanto que as restaurações cerâmicas (onlays/coroas) fraturaram em média a 1347N e 1280N respectivamente (46,7% e 20%), sendo esta diferença estatisticamente significante (P<0,0001). As falhas foram classificadas somente em fraturas parcial ou total das restaurações. Fratura do pilar, afrouxamento de parafuso, ou ambos, não foram observados.Restaurações de resina composta Paradigm MZ100 cimentadas adesivamente sobre pilares personalizados de zircônia apresentaram maior resistência à fadiga quando comparadas às restaurações de cerâmica Paradigm C com designs similares. / This study assessed the fatigue resistance and failure mode of porcelain and composite resin crowns and onlays bonded to custom zirconia premolar implant abutments.Sixty standardized zirconia implant abutments were milled (NeoShape) according to two different restoration designs (onlay or crown). Using Cerec 3, the corresponding onlays and crowns were fabricated either in ceramic (Paradigm C) or composite resin (Paradigm MZ100) (four experimental groups, n=15). The fitting surfaces of the abutments were airborne-particle abraded and cleaned. The intaglio surfaces of the restorations were HF-etched and silanated (Paradigm C) or airborne-particle abraded and silanated (Paradigm MZ100). Following abutments insertion of into a Morse taper implant (Titamax CM). All restorations were bonded with a zirconia primer (Z-Prime Plus), adhesive resin (Optibond FL) and a preheated light curing composite resin (Filtek Z100). Cyclic isometric chewing (5Hz) was simulated, starting with a load of 50N (5,000x), followed by stages of 200N, 400N, 600N, 800N, 1,000N, 1,200N and 1,400N (25,000x each). Samples were loaded until fracture or to a maximum of 180,000 cycles. The four groups were compared using the life table survival analysis (Logrank test at P=.05). All composite resin onlays and crowns survived (100% survival rate), while ceramic ones fractured at an average load of 1,347N and 1,280Nrespectively (survival rate of 46,7% and 20%), with a significant difference in survival probability (P<0.0001). Fractures consisted in partial or total failure of the restoration only (no abutment failure, no screw-loosening). Composite resin restorations (onlays/crowns) bonded to custom zirconia implant abutments presented a significant higher survival rate when compared to ceramic ones.
346

Resistência à fadiga e propensão a trincas em restaurações amplas de resina composta em dentes posteriores

Silva, Silvana Batalha January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T02:38:11Z (GMT). No. of bitstreams: 1 300935.pdf: 15104430 bytes, checksum: e0efd1452531a15b5dd6a0f22a4874a2 (MD5) / Este estudo in vitro comparou a influência de diversas técnicas restauradoras de resina composta (inlay de CAD/CAM versus restaurações diretas de resina composta, e outras variações indicadas para minimizar a contração de polimerização) em cavidades MOD amplas e seus efeitos na propensão a trincas e na resistência à fadiga acelerada. Métodos: preparos dentais padronizados MOD do tipo slot foram realizados em 92 molares superiores humanos (5 mm de profundidade e 5 mm de largura no sentido vestibulopalatal). Os dentes foram distribuídos aleatoriamente em seis grupos restauradores (n=15): inlays de resina composta usando blocos de Paradigm MZ100 usinados no Sistema CEREC 3 (Grupo MZ100); restauração incremental convencional de resina composta Miris 2 (Grupo M2); restauração utilizando uma técnica do sanduíche fechado modificado "superfechado", variando a base (cimento de ionômero de vidro convencional Ketac Molar - Grupo KM - e uma versão modificada por resina com Fuji II LC - Grupo FJ); restauração reforçada com fibra de polietileno Ribbond por meio de duas técnicas diferentes de aplicação no fundo da cavidade (uma única tira - Grupo BD - e múltiplos fragmentos - Grupo WP). Dois espécimes do grupo MZ100 serviram apenas como modelo para copiar a anatomia oclusal das restaurações diretas. Trincas geradas pela contração de polimerização dos materiais foram localizadas através de fotografias e transiluminação após uma semana dos procedimentos restauradores, e classificadas de acordo com sua severidade (menor ou maior que 3 mm). Logo após, cargas cíclicas isométricas (5 Hz) foram simuladas, começando com uma carga de 200 N (5.000 ciclos), seguida dos estágios de 400, 600, 800, 1.000, 1.200 e 1.400 N, com o máximo de 30.000 ciclos cada. Os espécimes foram desafiados até a fratura ou até o máximo de 185.000 ciclos. Os grupos foram comparados analisando-se a curva de sobrevivência de Kaplan-Meier (?=0,008, método de Bonferroni). Resultados: o grupo MZ100 foi o único a apresentar sobrevivência de 100%, diferente estatisticamente dos demais grupos (P<0,001). As técnicas diretas não apresentaram diferenças estatísticas entre si, embora o grupo FJ tenha apresentado a maior sobrevida (40% versus 13% para M2, 20% para KM, 7% para BD e 27% para WP). A maioria das falhas em todos os grupos foram restauráveis, com maior ocorrência de fraturas abaixo da junção cemento-esmalte (JCE) no grupo M2 e KM (três espécimes cada). O único grupo que não apresentou nenhuma falha abaixo da JCE foi o WP. O grupo MZ100 foi o menos propenso a trincas (apenas uma trinca menor que 3 mm); e, dentre as técnicas diretas, o grupo KM apresentou a menor ocorrência (67% de espécimes livres de trincas versus 60% no FJ, 46% no BD e 33% no WP), observando-se maior severidade no grupo M2. Conclusões: os inlays de CAD/CAM aumentaram a resistência à fadiga acelerada e diminuíram a propensão a trincas, quando comparados a restaurações diretas. A inclusão das bases de CIV/CIVMR não influenciou na resistência à fadiga e apresentou menor propensão a trincas em esmalte geradas pela contração de polimerização, quando comparada a restaurações de resina composta convencionais. As bases reforçadas por fibras também não interferiram na resistência à fadiga, mas parecem influenciar positivamente no modo de fratura. Todas as técnicas restauradoras alcançaram excelentes resultados sob fadiga em cargas mastigatórias fisiológicas, e especula-se que os inlays de CAD/CAM podem ser indicados para pacientes que apresentem altas cargas mastigatórias / This in vitro study compared the influence of various composite resin restorative techniques (CAD/CAM inlays vs. direct composite restorations as well as indicated variations to minimize polymerization shrinkage) for large MOD defects and its effect on the crack propensity and in vitro accelerated fatigue resistance. Methods: a standardized MOD slot-type tooth preparation was applied to 92 extracted maxillary molars (5 mm depth and 5 mm bucco-palatal width). Teeth were randomly distributed in 6 restorative groups (n=15): composite inlays with Paradigm MZ100 fabricated in CEREC 3 (MZ100 group); incremental and conventional composite resin restoration with Miris 2 (M2 group); a modified closed sandwich restoration called "super closed" sandwich technique with 2 different bases (glass ionomer cement (GIC) with Ketac Molar - KM group -, and a resin modified GIC with Fuji II LC - FJ group); a fiber reinforced restorations with 2 different placement techniques of Ribbond polyethylene fiber base (a single fiber piece - BD group - and multiple smaller pieces - WP group). Two specimens of MZ100 group were only used as a guide to copy occlusal anatomy while layering direct restorations. Cracks induced by polymerization shrinkage were tracked with photography and transillumination, and were classified according to their severity (more or less than 3 mm). Cyclic isometric chewing (5 Hz) was simulated, starting with a load of 200 N (5,000 cycles), followed by stages of 400, 600, 800, 1,000, 1,200 and 1,400 N at a maximum of 30,000 cycles each. Samples were loaded until fracture or to a maximum of 185,000 cycles. Groups were compared using the Kaplan-Meier life table survival analysis (?=.008, Bonferroni-method). Results: MZ100 group was the only group to survive 100%, with statistical difference from other groups (P<.001). There were no significant differences among direct techniques, nevertheless FJ had higher survival (40%, vs. 13% for M2, 20% for KM, 7% for BD and 27% for WP). Most of failures were re-restorable, with more catastrophic (below cementoenamel junction - CEJ) in M2 and KM groups (3 specimens for each). No failures below CEJ were found in WP group. MZ100 had almost no crack propensity (only 1 minor cracking, less than 3 mm); and KM presented the lower occurrence of induced cracks in direct techniques (67% of free cracks samples, vs. 60% for FJ, 46% for BD and 33% for WP), with higher severity in M2 group. Conclusions: CAD/CAM inlays increased the accelerated fatigue resistance and decreased the crack propensity when compared to direct restorations. Inclusion of GIC/RMGIC bases did not affect their fatigue strength and tend to decrease the shrinkage-induced enamel crack propensity. Fiber-reinforced bases also did not affect their fatigue strength but seem to positively influence the failure mode. All technique restorations yielded excellent fatigue results at physiological masticatory loads, and CAD/CAM inlays may be extended even to high-load patients
347

Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendas /

Souza, Niélli Caetano de. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / Abstract: The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique. / Orientador: Alexandre Henrique Susin / Coorientador: Osmir Batista de Oliveira Junior / Banca: Marcelo Ferrarezi de Andrade / Banca: Roselaine Terezinha Pozzobon / Doutor
348

Selamento de lesões cariosas oclusais : um ensaio clínico randomizado

Giongo, Fernanda Cristina Mendes de Santana January 2010 (has links)
As evidências mostram uma redução ou eliminação significativa na quantidade de bactérias viáveis sob selantes e restaurações e consequente diminuição na progressão da cárie quando as bactérias se encontram separadas do meio bucal. O objetivo deste ensaio clínico controlado randomizado foi avaliar a eficácia de duas estratégias de tratamentos: 1) selamento de lesões de cárie oclusal e 2) tratamento restaurador convencional com remoção total da dentina cariada em dentes permanentes. A amostra foi constituída de 52 dentes com lesões de cárie na superfície oclusal (pré-molares e/ou molares) de 47 pacientes com idade entre 8 a 43 anos. Todas as lesões de cárie apresentaram necessidade de tratamento restaurador de acordo com os seguintes critérios: presença de cavidade e impossibilidade de controle do biofilme. A profundidade máxima das lesões foi até a metade externa de dentina avaliada através de radiografias interproximais. Os dentes foram divididos aleatoriamente em um grupo teste - tratamento selante, ou grupo controle - tratamento restaurador convencional. Dados iniciais referentes à experiência de cárie (CPOD) e índice de sangramento gengival (ISG) foram avaliados. Radiografias interproximais foram realizadas após 12 meses para avaliar a integridade das restaurações e a zona radiolúcida (ZR) sob os selantes/restaurações. Os desfechos analisados foram o desempenho clínico dos tratamentos selante e restauração e a prevalência de regressão, inativação e progressão da cárie com exames radiográficos. A presença de dentina terciária também foi observada. Os dados foram avaliados por meio do teste exato de Fisher. Um total de 26 selantes e 26 restaurações foram realizadas. Não houve diferença entre os grupos quanto às características iniciais - idade, sexo, CPOD e ISG. Após um ano, foram avaliados 49 dentes, apresentando taxas de sucesso de 95,8% e 100% nos grupos selante e restauração convencional, respectivamente (p>0,05). Houve uma falha em um dos tratamentos (perda total no grupo selante) observada durante o estudo. A avaliação radiográfica (progressão, inativação, regressão e presença de dentina terciária) não demonstrou diferença entre os grupos. Nenhum dos dentes apresentou progressão de cárie; a regressão foi observada em apenas um caso (grupo do selante) e a presença de dentina terciária foi encontrada em 12,5% da amostra (5 selantes e 1 restauração). Selantes podem ser utilizados como tratamento terapêutico para lesões de cárie incipientes em dentes permanentes, uma vez que impedem a progressão das lesões de cárie, preservando a estrutura do dente, quando comparado ao tratamento restaurador convencional. / There is a significant decrease in the number of viable microorganisms under sealants and restorations and a consequent decrease in caries progression when bacteria are separated from the oral environment. The aim of this randomized controlled clinical trial was to evaluate the efficacy of two treatments strategies: 1) sealing of carious lesions and 2) operative restorative treatment of occlusal carious lesions in permanent teeth. The sample consisted of 52 carious posterior teeth (premolars and molars) from 47 patients aged 8 - 43 years. In all lesions restorative treatment was necessary according to the following current strategies: presence of cavity and impossibility to perform biofilm control. The maximum depth of lesions was halfway through the dentine assessed by bitewing radiograph. The teeth were randomly assigned to test group – sealant treatment or control group - conventional restorative treatment. Baseline caries experience (DMFT) and gingival bleeding index (GBI) was assessed. Bitewing radiographs were performed after 12 months to evaluate the integrity of the restorations and the radiolucent zone (ZR) beneath the sealants/restorations. Outcomes were defined as clinical performance of sealant and restoration and the prevalence of regression, inactivation and progression of carious lesion by radiographic examinations. Presence of tertiary dentine was also evaluated. The data were submitted to Fisher`s exact test. A total of 26 sealants and 26 restorations were performed. There were no differences between the two groups regarding baseline characteristics – age, gender, DMFT and GBI. After one year, 49 evaluations had been performed, showing 95.8% and 100% of success rates in test and control group respectively (p>0.05). There was one therapeutic failure (total loss in the sealant group) observed during the study. No difference in the radiographic evaluation (progression, inactivation, regression and tertiary dentin deposition) was observed between the groups (p>0.05). No teeth showed caries progression; regression was observed in only one case (sealant group) and tertiary dentin was founded in 12.5% of the sample (5 sealants and 1 restoration). Sealants can be used as a therapeutic treatment for incipient carious lesions in permanent teeth, since they prevent the progression of carious lesions, while preserving tooth structure when compared to conventional restorative treatment.
349

Efeito do pré-aquecimento e da pré-refrigeração na dureza e contração de um compósito fotoativado com luz halógena e LED / Fernando Henrique Ruppel Osternack ; orientador, Rui Fernando Mazur

Osternack, Fernando Henrique Ruppel January 2011 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2011 / Inclui bibliografias / Os objetivos deste estudo foram avaliar in vitro a dureza e a contração de uma resina composta híbrida pré-refrigerada ou pré-aquecida, fotoativados com aparelhos de luz halógena (QTH) e diodo emissor de luz (LED). Adicionalmente, a temperatura da ponta d / The aim of this study was to evaluate in vitro the hardness and shrinkage of a pre-cooled or pre-heated hybrid composite resin photoactivated by a quartztungsten- halogen light (QTH) and light emitting diode (LED) light-curing units. Additionally, the tem
350

Influência da densidade de energia nas propriedades mecânicas (dureza e módulo de elasticidade) e no aquecimento de uma resina composta fotopolimerizada por LED experimental / Juliana Maria Habith Martin ; orientador, Rui Fernando Mazur ; co-orientador, Paulo César Soares Jr

Martin, Juliana Maria Habith January 2010 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Inclui bibliografias

Page generated in 0.0734 seconds