• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Obtenção e caracterização de compósitos de benzoxazina/fibra de carbono / Obtainment and preparation of carbon fiber/benzoxazine composite

Bandeira, Cirlene Fourquet [UNESP] 17 July 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-17. Added 1 bitstream(s) on 2015-09-17T15:45:08Z : No. of bitstreams: 1 000846869.pdf: 4019979 bytes, checksum: dd307b06e2be686adf7e95b88b2fdd4d (MD5) / Ao encontro das necessidades de um mercado cada vez mais exigente, uma série de novas resinas vem sendo desenvolvidas; dentre estas as resinas polibenzoxazinas, que constituem uma nova classe de resinas fenólicas termorrígidas, que vem superando as propriedades das tradicionais resinas epóxi e fenólica, quando aplicadas na indústria aeroespacial. Com isto, o presente trabalho tem como objetivo sintetizar a resina benzoxazina de alto desempenho denominadas oAI-a (benzoxazina orto-amida-imida), processar compósitos de benzoxazina/fibra de carbono via'Hand lay up', utilizando as resinas benzoxazina fenol-diamino difenil metano (P-DDM), a resina oAI-a e a resina benzoxazina comercialmente disponível (Epsilon 99100 RTM), via moldagem por compressão a quente, e caracterizar suas propriedades físico-químicas, tanto em condições secas como expostas a radiação ultravioleta, umidade e calor e querosene de aviação, dando subsídios para o domínio da produção e caracterização de novos materiais com aplicações aeroespaciais. Os resultados obtidos a partir deste trabalho foram comparados entre si e com as propriedades mecânicas e térmicas das tradicionais resinas epóxi e fenólica disponíveis na literatura. Os resultados mostram que os compósitos de resina benzoxazina Epsilon 99100 RTM e P-DDM apresentam boa consolidação, temperatura de transição vítrea em torno de 162°C, para a resina Epsilon 99100 RTM e 168°C para a resina P-DDM e boa estabilidade térmica. No caso dos compósitos obtidos com a resina Epsilon 99100 RTM, o condicionamento por imersão em água reduziu sua Tg em 12%, e até 4,5% para as amostras condicionadas em UV, quando comparadas com as amostras não condicionadas. Foi também observado que para as amostras expostas ao querosene de aviação houve um aumento do valor da Tg de até 3,5%, quando comparado com os ... (Resumo completo, clicar acesso eletronico abaixo) / A series of new resins have been developed meeting the needs of an increasingly demanding market, among these the polibenzoxazin resins which constitute a new class of thermoset phenolic resin, which is overcoming the properties of traditional epoxy and phenolic resins when applied in the aerospace industry. With this, the present work aims to synthesize high performance benzoxazine resin called oAI-a (ortho-amide-imide benzoxazin), process composite benzoxazin/carbon fiber via'Hand lay up'using the benzoxazin phenol resins diamino diphenyl methane (P-DDM), the resin oAI-a and the benzoxazine resin commercially available (Epsilon 99100 RTM) via compression hot molding and characterize their physical and chemical properties both under dry conditions and exposed to ultraviolet radiation, humidity and heat and jet fuel, helping it to control production and characterization of new materials with aerospace applications. The results obtained from this study were compared between themselves and with the mechanical and thermal properties of traditional epoxy and phenolic resins available in the literature. The results show that benzoxazine resin composites Epsilon 99100 RTM and P-DDM exhibit good consolidation glass transition temperature around 162°C to the resin Epsilon 99100 RTM and 168°C to the resin P-DDM and good thermal stability. In the case of the composites obtained with Epsilon 99100 RTM resin the conditioning by immersion in water its Tg was reduced 12%, and up to 4.5% for samples UV conditioned when compared to nonconditioned samples. It was also observed that for the samples exposed to aviation kerosene was an increase in the Tg value of up to 3.5% compared with the results obtained in nonconditioned samples. In addition, samples conditioned in water showed an increase of interlaminar shear strength(22%) compared to non-conditioned samples; while the samples immersed in jet fuel showed no significant variation in their performance
362

INFLUÊNCIA DE AGENTES CLAREADORES NA COR DE RESINAS COMPOSTAS DE DIFERENTES OPACIDADES ARMAZENADAS EM MEIOS DISTINTOS / EFFECT OF BLEACHING AGENTS ON COLOR OF COMPOSITE RESINS WITH DISTINCT OPACITYS STORED IN DIFERENT MEDIAS

Lago, Maristela 26 March 2012 (has links)
The aim of this study was to evaluate the influence of two bleaching agents on color of one composite resin (Filtek Z350 XT - 3M ESPE) in the opacities of enamel and dentin, previously subjected to the action of deionized water or red wine. Sixty specimens (sp) were made for each composite resin using a metal matrix with 8 mm diameter and 2 mm thickness. Immediately after polymerization with LED (Emitter Schuster / Santa Maria Rio Grande do Sul, Brasil) for 40 s, the sp were polished with Diamond Pro discs (FGM / Joinvile SC, Brasil), and felt discs with diamond paste (Diamond Excel FGM / Joinvile SC, Brasil), then sp were washed in water and dried. The sp were divided into two groups for each opacity: immersed in red wine or deionized water for 14 days and then divided into three subgroups: one group subjected to bleaching with hydrogen peroxide 35% (Mix One Lot: 043 - Dental Villevie Brasil Ltda), one group submitted to bleaching with carbamide peroxide 16% (Mix Night - Lot: 007 - Dental Villevie Brasil Ltda) and one group not subjected to bleaching. Successive measurements were conducted 24 hours after polishing procedures, after 14 days of immersion on their respective immersion media, and after the action of the bleaching agents, using a spectrophotometer (SP60 EX-Rite / Grand Rapid Michigan, USA), with CIE L* a* b* system. Data were analyzed with t-test, one-way ANOVA, and Tukey (5%). Red wine caused significant color change in the composites in relation to water, and the enamel resin presented greater color change than the dentin resin. Bleaching agents partially removed the pigmentation of the sp which were immersed in wine, and the carbamide peroxide showed more significant results. The bleaching agents did not determine significant results when the sp were immersed in water. Red wine had great influence on the color change of composite resins and water caused no significant color change. The bleaching agents were capable of partial removal of the pigmentation produced by red wine. / Este trabalho teve por objetivo avaliar a influência de dois agentes clareadores sobre a cor de uma resina composta (Filtek Z350 XT 3M ESPE) nas opacidades de esmalte e dentina, previamente submetidas à ação de água deionizada ou vinho tinto suave. Foram confeccionados 60 corpos-de-prova (cps) para cada resina composta utilizando uma matriz metálica com 8 mm de diâmetro e 2 mm de espessura. Imediatamente após a fotoativação com um LED (Emitter Schuster / Santa Maria Rio Grande do Sul, Brasil) por 40s, os cps foram polidos com discos Diamond Pro (FGM / Joinvile SC, Brasil) e disco de feltro com pasta diamantada (Diamond Excel FGM / Joinvile SC, Brasil), lavados em água e secos. Os cps foram divididos em 2 grupos para cada opacidade: imersos em vinho tinto suave ou em água deionizada, por 14 dias e subdivididos em 3 subgrupos: um grupo submetido ao clareamento com peróxido de hidrogênio 35% (Mix One Lot: 043 - Dental Villevie Brasil Ltda), um grupo submetido ao clareamento com peróxido de carbamida 16% (Mix Night - Lot: 007 - Dental Villevie Brasil Ltda) e um grupo não submetido ao clareamento. Sucessivas leituras foram realizadas após 24 horas da confecção dos corpos-de-prova (inicial), após 14 dias de imersão nos respectivos meios; e após a ação de agentes clareadores utilizando um espectrofotômetro (SP60 EX-Rite / Grand Rapid Michigan, USA), com o sistema CIE L* a* b*. Os dados foram submetidos ao Teste t, análise de variância uma via e Tukey (5%). O vinho tinto suave causou significativa alteração de cor nas resinas compostas em relação à água, sendo que, a resina composta de esmalte sofreu maior alteração de cor que a de resina composta de dentina. Os agentes clareadores removeram parcialmente o pigmento dos cps que foram imersos em vinho, sendo que o peróxido de carbamida apresentou resultados mais significativos. Já quando os cps foram imersos em água os agentes clareadores não determinaram resultados relevantes. O vinho tinto suave teve grande influência na alteração de cor das resinas compostas e a água não causou alteração de cor significativa. Os géis clareadores foram capazes de fazer a remoção parcial da pigmentação produzida pelo vinho tinto.
363

EFEITO DE AGENTES CLAREADORES À BASE DE PERÓXIDO DE HIDROGÊNIO SOBRE A FLUORESCÊNCIA DE RESINAS COMPOSTAS / EFFECT OF HYDROGEN PEROXIDE BLEACHING AGENTS ON FLUORESCENCE OF COMPOSITE RESINS

Bueno, Renata Plá Rizzolo 29 November 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Due to the increasing search for an aesthetic smile, the demand for less invasive procedures, such as in composite restoration and tooth bleaching, also increased. The composite resins have optical properties and one of these properties is the fluorescence which is intended to give naturalness to restoration mimicking them in the natural dentition. The aim of this study was to evaluate the effect of bleaching agents based on hydrogen peroxide on the fluorescence of different composites. For this, 30 specimens were made, 10 for each composite resin (4 Seasons and Opallis), measuring 10mm in diameter and 2mm thickness with the aid of a matrix of acrylic split. After fabrication, the samples were polished on politriz with abrasive paper grit 600, 1.200 and 2.500. Before exposing the specimens to the bleaching agents (White Class 7.5% with calcium and Whiteness HP Blue 35% with calcium) was held the first reading of fluorescence through the apparatus fluorescence spectrophotometer Cary Eclipse. Exposures to hydrogen peroxide were performed according to the manufacturers. After this procedure (30 days) was performed the second reading of fluorescence. The values were statistically analyzed by paired t test, Student t test, analyses of variance and multiples comparisons test of Tukey (p <0.05). The results showed that the composite resins evaluated had different behaviors in all groups, and after exposure to hydrogen peroxide 7.5% only 4 Seasons significantly changed and the Opallis significantly changed when stored in deionized water. The resin Opallis showed more instability in relation to the fluorescence, hydrogen peroxide 7.5% (homemade method) determined the biggest changes in the values of fluorescence and time of exposure to the bleaching agent affected more the fluorescence of the resin composite 4 Seasons than its concentration. / Devido à crescente busca por um sorriso estético, a procura por procedimentos menos invasivos, como a restauração em resina composta e o clareamento dental, também aumentou. As resinas compostas apresentam propriedades ópticas, sendo que uma destas propriedades é a fluorescência, que destina-se a dar naturalidade à restauração mimetizando-as à dentição natural. O objetivo deste estudo foi avaliar o efeito de agentes clareadores à base de peróxido de hidrogênio sobre a fluorescência de resinas compostas. Para isso, foram confeccionados 30 corpos-de-prova, sendo 10 para cada resina composta (4 Seasons e Opallis), medindo 10mm de diâmetro e 2mm de espessura com o auxílio de uma matriz de acrílico bipartida. Após a confecção, os corpos-de-prova foram polidos no aparelho politriz com as lixas de granulação 600, 1.200 e 2.500. Antes de expor os corpos aos agentes clareadores (White Class com cálcio 7,5% e Whiteness HP Blue com cálcio 35%), foi realizada a primeira leitura de fluorescência através do aparelho espectrofotômetro de fluorescência Cary Eclipse. As exposições aos peróxidos de hidrogênio foram realizadas conforme indicação do fabricante. Após este procedimento (30 dias) foi realizada a segunda leitura de fluorescência. Os valores obtidos foram analisados estatisticamente através do teste t pareado, teste t de Student, análise de variância e teste de múltiplas comparações de Tukey (p<0,05). Os resultados evidenciaram que as resinas compostas avaliadas obtiveram comportamentos diferentes em todos os grupos, sendo que após a exposição ao peróxido de hidrogênio 7,5% somente a resina 4 Seasons apresentou alteração significativa, já a resina Opallis apresentou alteração significativa quando armazenada em água deionizada. A resina Opallis apresentou maior instabilidade em relação à fluorescência, o peróxido de hidrogênio 7,5% (método caseiro) foi o que determinou maiores alterações nos valores de fluorescência e o tempo de exposição ao agente clareador afetou mais a fluorescência da resina composta 4 Seasons do que sua concentração.
364

AVALIAÇÃO DA COR DE RESINAS COMPOSTAS EM MEIOS E TEMPOS DE ARMAZENAMENTO DISTINTOS USANDO DOIS ESPECTROFOTÔMETROS / COLOR EVALUATION OF RESIN COMPOSITES IN DIFFERENT MEANS AND TIMES OF STORAGE USING TWO SPECTROPHOTOMETERS

Diesel, Pâmela Gutheil 07 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the color of composite resins when stored in water and red wine, during different periods (immediately after polymerization, 24 hours, 30 days and 180 days) comparing the two measurements of spectrophotometers (Easyshade - Vita and SP60 - X-Rite). Four resin composites were used in two opacities (dentin and enamel): Filtek Supreme XT, Ice, and Opallis Brilliant. After confection 14 specimens (sp) for each resin composite using a metal matrix with 10 mm diameter and 2 mm thick, light cure with a LED (±800mW/cm2) by 40s, sp were polished with Sof-Lex Pop On and felt disc with diamond paste, washed with water and dried with gauze. Immediately after polishing, the initial measurement of the sp was performed, using the CIE L * a * b *. The sp of each composite resin were divided into two groups (n = 7) according to the storage media. Successive readings were taken at 24h, 30 days and 180 days. The color change (ΔE) was calculated using the formula ΔE = ((ΔL)2 + (Δa)2 + (Δb)2)½. The data were subjected to Student t Test and Pearson Linear Correlation for comparison of two spectrophotometers, and ANOVA and Tukey (5%) for each spectrophotometer. In both spectrophotometers, the resins immersed in red wine showed greater change than those kept in water and these values increased over time for most resins. For ΔE obtained by the SP60, the sp immersed in water remained stable, contrary to what was measured by Easyshade that had color changes over time. Although the values of ΔE measured at Easyshade and SP60 were significantly different, they were highly correlated. / O objetivo deste trabalho foi avaliar a cor de resinas compostas quando armazenadas em água e em vinho tinto, durante períodos distintos (imediatamente após a fotoativação, 24h, 30 dias e 180 dias) comparando a leitura realizada por dois espectrofotômetros (Easyshade - Vita e SP60 - X-Rite). Foram utilizadas 4 resinas compostas em 2 opacidades (esmalte e dentina): Filtek Supreme XT, Ice, Brilliant e Opallis. Após a confecção de 14 corpos-de-prova (cps) para cada resina composta, utilizando uma matriz metálica com 10 mm de diâmetro e 2 mm de espessura, fotoativados com um LED (±800mW/cm2), por 40s, os cps foram polidos com discos Sof-Lex Pop On e disco de feltro com pasta diamantada, lavados em água e secos com gaze. Imediatamente após o polimento, foi feita a mensuração inicial dos cps nos dois aparelhos utilizando o sistema CIE L* a* b*. Os cps de cada resina composta foram divididos em dois grupos (n=7) de acordo com os meios de armazenamento. Sucessivas leituras foram realizadas nos períodos de 24h, 30 dias e 180 dias. A alteração de cor (ΔE) foi calculada utilizando a formula ΔE = ((ΔL)2 + (Δa)2 + (Δb)2)½. Os dados foram submetidos ao Teste t de Student e Correlação Linear de Pearson para comparação dos dois aparelhos e à Análise de Variância e Teste de Tukey (5%) para cada um dos aparelhos. Nos dois aparelhos, as resinas imersas em vinho tinto apresentaram maior alteração que as mantidas em água e esses valores aumentaram ao longo do tempo para a maioria das resinas. Para ΔE obtidos pelo SP60, os cps mantidos em água mantiveram-se estáveis, ao contrário do que foi mesurado pelo Easyshade que teve alterações de cor com o passar do tempo. Embora os valores de ΔE mensurados pelo Easyshade e SP60 tenham sido significativamente diferentes, eles foram altamente correlacionados.
365

Deflexão cuspídea e resistência à fratura em dentes restaurados

Rocha, Daniel Maranha da [UNESP] 16 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-16Bitstream added on 2014-06-13T19:20:21Z : No. of bitstreams: 1 rocha_dm_dr_sjc.pdf: 501808 bytes, checksum: d965f3ab0fb785017ed14a552084fe08 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A proposta desse estudo foi avaliar a deflexão cuspídea e a resistência à fratura de pré-molares, com e sem tratamento endodôntico, restaurados com diferentes técnicas e materiais restauradores. Para tal foram utilizados 60 pré-molares hígidos, extraídos por motivos ortodônticos que foram divididos em 6 grupos. Seis dentes foram mantidos hígidos, formando o grupo controle positivo (C POS), outros 6 receberam preparos tipo MOD e não receberam procedimentos restauradores formando o Grupo controle negativo (C NEG). Os demais 48 dentes foram divididos em 4 grupos de 12 dentes que foram restaurados de acordo com cada grupo. No grupo RC os dentes foram restaurados diretamente com resina composta, os demais grupos receberam tratamento endodôntico. No grupo CIV, os dentes tiveram as suas câmaras pulpares preenchidas com cimento de ionômero de vidro e posteriormente restauradas com resina composta, no grupo PM os dentes receberam pinos metálicos e foram restaurados com resina composta e por fim, os dentes do grupo PF receberam pinos de fibra de vidro e foram restaurados diretamente com resina composta. Os corpos-de-prova foram então submetidos a um ensaio não destrutivo de compressão a fim de se realizar a medição de deflexão das cúspides dos dentes de cada grupo e posteriormente, realizou-se o ensaio destrutivo a fim de registrar as medidas de resistência à fratura de cada grupo envolvido. Podem-se perceber diferenças estatisticamente significantes entre os grupos experimentais e os grupos controle, tanto para a deflexão das cúspides (CNEG: 81,0 με; CPOS: 5,20 με; RC: 17,73 με; CIV: 17,63 με; PF: 20,61 με; PM: 24,29 με) quanto para os valores de resistência à fratura (CNEG: 5,212 Kgf; CPOS: 128,22 Kgf; RC: 48,89 Kgf; CIV: 18,41 Kgf; PF: 29,81 Kgf; PM: 37,51 Kgf). Entre os grupos experimentais podem-se notar diferenças estatisticamente significantes... / The aim of this study was to evaluate de cuspal deflection and the fracture resistance of pre-molars, with and without endodontic therapy, using different restorative techniques and materials. Sixty sound teeth, extracted by orthodontic reasons were divided in 6 groups. Six teeth remained unprepared and formed the positive control group, other 6 teeth were MOD prepared and remained unrestored forming the negative control group. The remaining 48 teeth were divided in 4 groups with 12 teeth each and were restored following the groups. The RC group teeth were directly restored with composite resins. The other 3 groups received endodontic therapy. At the CIV group, the pulpal chambers of the endodontic treated teeth were fulfilled with glass ionomer cements an then directly restored with composite resin, the PM group teeth were restored with a metallic post and then directly restored with composite resin, in the PF group were used a fiber glass post and then direct composite restoration. The specimens was submitted first to non-destructive compression test due to cuspal deflection measurements, and then submitted to a destructive compression test to evaluate the fracture resistance of the specimens. Statistical differences were perceived when the experimental groups were compared to the control groups thus cuspal deflection (CNEG: 81,0 με; CPOS: 5,20 με; RC: 17,73 με; CIV: 17,63 με; PF: 20,61 με; PM: 24,29 με) and fracture resistance (CNEG: 5,212 Kgf; CPOS: 128,22 Kgf; RC: 48,89 Kgf; CIV: 18,41 Kgf; PF: 29,81 Kgf; PM: 37,51 Kgf). Differences between the experimental groups were verified both cuspal deflection, with a better performance of the RC and the CIV groups. The PM group showed the highest values of cuspal deflection. Concerning fracture resistance, the highest values were presented by the RC and CIV groups and the worst performance presented... (Complete abstract click electronic access below)
366

Avaliação do selamento marginal em restaurações de resina composta executadas em dentes bovinos, variando os métodos de preparos cavitários e os meios de fotopolimerização

Jorge, André Luiz Cervantes [UNESP] 13 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-13Bitstream added on 2014-06-13T20:41:40Z : No. of bitstreams: 1 jorge_alc_dr_sjc.pdf: 1158280 bytes, checksum: 7824b0ac492ac3bb52d9487cd2606177 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Avaliou-se o selamento marginal de restaurações de resina composta em dentes bovinos empregando-se o teste de microinfiltração, variando-se os métodos de preparos cavitários e os meios de fotopolimerização. Foram selecionados 60 dentes bovinos, e divididos em 2 grupos (1 e 2) de 30 dentes cada. Executou-se preparos cavitários tipo “pires”, através de dois métodos:Turbina de alta rotação e ponta de diamante e Laser de Érbio:YAG. Após os preparos cavitários, os grupos foram subdivididos em 2 subgrupos, (A e B) de 15 dentes cada. Após condicionamento com ácido fosfórico a 37%, receberam o primer/adesivo Single Bond 2 – 3M/ESPE e foram restaurados com a resina composta Z250-3M/ESPE em dois incrementos, com diferentes fotopolimerizações: os grupos 1A e 2A foram fotopolimerizados por 10s à 14mm da superfície (180mW/cm²), e depois uma fotopolimerização por 20s em contato com a resina com um aparelho XL3000 – 3M por 30s cada incremento, e o grupo 1B e 2B com um aparelho LED – RADII - SDI da mesma maneira descrita anteriormente. Cinco amostras de cada subgrupo (20) foram preparadas para avaliação em MEV, com o objetivo de visualizar as características resultantes da ação dos equipamentos de preparo cavitário e ilustração. Para o teste de microinfiltração marginal, os dentes foram termociclados por 500 ciclos, (5ºC-55ºC), submersos em solução de nitrato de prata 50% por 24 horas e então lavados por 20min, colocados em solução reveladora de radiografias por 8 horas. Os dentes foram seccionados e as imagens foram digitalizadas para análise da área da microinfiltração através do programa Image Toll 3.0. Após aplicar os testes ANOVA e Tukey (5%), pudemos concluir que: nenhum dos métodos de preparo cavitário ou meios de fotopolimerização impediram a microinfiltração marginal; o preparo com Laser de Er:YAG apresentou... / The purpose of this study was to evaluate the influence of method of the cavity and which are the best resources in photopolymerization of resin based composites. It was select 60 bovine teeth and they were divided in two groups: Group one was prepared plate type cavities with turbine and diamond burs and group 2 plate type cavities prepared with Er:YAG laser. They were divided in subgroups 1A, 2A, 1B, 2B, and after the etching and bonding procedures, the composite resin, Z250 -3M-ESPE was apllied in 2 equal increments for each cavity preparation and photopolymerized in two different techniques. In two step curing, being the first step 14 centimeters from the surface for 10s / 180mW/cmø and second step for 20s / 550mW/cmø , with a LED curing unit - Radii - SDI, and with a XL 3000 curing - 3M-ESPE at the same way related before. The specimens were thermocycled for 500 thermocycles and dye penetration with a solution of silver nitrate 50% was used to quantify the scores of microleakage in a program Image Tool 3.0. The data was analysed with ANOVA and Tukey test (5%). The results were: a-) no one cavity preparation or photocuring method avoided microleakage, b-) The Er:YAG laser presented more miroleakage , although no significant, c-) Photocuring with LED presented better results qhen compared with XL 3000, statistically significant.
367

Desenvolvimento e avaliação da efetividade de duas pastas polidoras em padrão nanométrico empregadas a materiais restauradores estéticos: análise comparativa por perfilometria digital e microscopia de força atômica

Elossais, André Afif [UNESP] 28 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-28Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 elossais_aa_dr_arafo.pdf: 996142 bytes, checksum: 88037f1a3f60e9e1dfbc58af37913bed (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Considerando a recente introdução de resinas nanoparticuladas no mercado odontológico, este trabalho teve o propósito de desenvolver duas pastas polidoras em padrão nanométrico e estudar os tratamentos superficiais e técnicas de polimento comumente empregadas para as diferentes resinas já disponíveis e também para esses novos produtos. Foram confeccionados 40 corpos-de-prova para cada resina composta: Vit-l-escence™ – microhíbrida (M1) e Filtek™ Z350 – nanoparticulada ou nanoaglomerada (M2). As amostras foram armazenadas por 24 horas em água destilada a 37_C + 1_C, para então serem submetidas ao tratamento superficial, onde a rugosidade média (Ra) foi analisada em quatro etapas consecutivas: Grupo Controle – T0 (Controle A – tira de poliéster Mylar™ e Controle B – Pincel Hot Spot™ Design); polimento com o sistema de discos abrasivos – T1 (Sof-Lex Pop On™); polimento com pastas abrasivas em padrão micrométrico – T2 (Diamond Polish Paste™ e Enamelize™) e polimento com pastas abrasivas nanométricas – T3 (Lummina-E Diamond e Lummina-E Alumina). Os resultados obtidos revelaram que, em todas as etapas observadas, as resinas compostas exibiram valores de rugosidade média muito satisfatória, sendo que a resina composta M1 alcançou os menores valores. Quando empregada a Tira de Poliéster Mylar™ como Grupo Controle (Controle A), os menores valores de rugosidade média foram inqüestionavelmente observados na etapa T0. Quando empregados os discos abrasivos Sof-Lex Pop On™ (etapa T1), a rugosidade média das amostras aumentou significativamente quando comparado à etapa T0 (Grupo Controle A – Tira de Poliéster Mylar™). Ao se eliminar a etapa T1 do Grupo Controle B (Pincel Hot Spot Design™), na etapa T2 os valores de rugosidade média diminuíram substancialmente, porém, continuaram superiores àqueles obtidos pelo Controle A e também pelo... / Considering the recent introduction of nanocluster resin-based materials in dentistry market, this work had the intention to develop two nanometricpatterned polish pastes and to also evaluate whether the polishing techniques commonly used, and which feature satisfactory results for the different resins already available, are appropriate for these new products. Fourty test specimens were fabricated for each composite resin: Vit-lescence ™ – micro-hybrid particles (M1) and Filtek™ Z350 – nanoparticled or nanocluster (M2). The samples were stored within distilled water at 37_C + 1_C by 24 hours and submitted to surface treatment, where the mean roughness was assessed in four consecutive phases: control – T0 (standardization with polyester matrix bands and Hot Spot Design™ brush); polishing with abrasive disc system – T1 (Sof-Lex Pop On™); polishing with micro-patterned polishing pastes – T2 (Diamond Polish Paste™ and Enamelize™) and polishing with nano-patterned polishing pastes – T3 (Lummina-E Diamond and Lummina-E Alumina). Obtained results showed that, in all the phases observed, the composite resins featured rather satisfactory mean roughness scores, where composite resin M1 reached the lowest scores. It was demonstrated that the lowest mean roughness scores were unquestionably observed in phase T0 for all the composite resins, where the test specimens’ standardization was performed with polyester matrix bands (control group). When the abrasive discs were used (phase T1), the samples mean roughness had a significant increase when compared to phase T0. When phase T1 was eliminated in Control Group B (Hot Spot Design™ brush), in the phase T2 mean roughness values had decreased substantially, however, they had continued higher compared to Control A and B. In phase T2 (polishing with micro-patterned pastes) mean roughness values also decreased compared to phase... (Complete abstract click electronic access below)
368

Análise das tensões geradas durante a contração de polimerização e aplicação de cargas em restaurações diretas de resina composta. Efeito da utilização de materiais para base ou forramento

Oliveira, Luana Cristina Araújo de [UNESP] 26 June 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-06-26Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 oliveira_lca_dr_arafo.pdf: 2273954 bytes, checksum: 3107451a04bf448e6e343be28108c606 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta investigação científica foi analisar o efeito da presença de materiais para base ou forramento, nas tensões geradas durante a contração de polimerização e aplicação de cargas, em cavidade classe I, no segundo pré-molar superior. Foram avaliadas quatro técnicas restauradoras: 1) Resina composta Z250(3M ESPE) controle, 2) Resina composta Z250(3M ESPE) + forramento com resina de baixa viscosidade FiltekFlow(3M ESPE), 3) Resina composta Z250(3M ESPE) + Forramento com ionômero de vidro modificado por resina Vitrebond(3M ESPE) e 4) Resina composta Z250(3M ESPE) + base com ionômero de vidro modificado por resina Vitrebond(3M ESPE). O estudo transcorreu em três fases: 1)Fotoelasticidade, 2)Tensilometria e 3)Elementos Finitos. 1ª Fase (Fotoelasticidade) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização na cavidade confeccionada em modelo fotoelástico, restaurada com as técnicas descritas acima, nomeadas F1, F2, F3 e F4 respectivamente e determinada a Tensão Cisalhante Máxima(tmáx ) na interface adesiva e realizados os Testes ANOVA e Tukey (p=0,05). 2ª Fase (Tensilometria) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização de cada material, assim agrupados: T1 - resina composta, T2 - resina de baixa viscosidade e T3 - Ionômero de vidro modificado por resina, os quais foram inseridos entre duas bases cilíndricas de dentina bovina (diâmetro 4,0 mm) com espessura de 2,0mm, sendo que a base superior foi conectada a uma célula de carga. Os valores de força foram registrados iniciando simultaneamente com a fotopolimerização até a completa estabilização das forças... / The aim of this study was analyze the effect of liner and base materials presence during polymerization shrinkage and load application, on cavities class I, in maxillary premolar. The following technique were assigned: 1) Composite resin Z250(3M ESPE)-control, 2) Composite resin Z250(3M ESPE) + liner with flowable FiltekFlow (3M ESPE) 3) Composite resin Z250(3M ESPE) + liner with resin-modified glass-ionomer Vitrebond(3M ESPE) e 4) Composite resin Z250(3M ESPE) + base with resin-modified glass-ionomer Vitrebond(3M ESPE). The study was divided in three phases: 1) Photoelasticity, 2) Tensilometry e 3) Finite Elements Analysis. 1ª (Photoelasticity) - In this phase was determinate polymerization shrinkage stress in photoelastic model, filled with techniques, named F1, F2, F3 e F4 respectively and Maximal Shear Stress (tmáx) was determinate along adhesive interface. Results were analyzes by Anova and Tukey Test. (p=0,05). 2ª (Tensilometry) - In this phase was determinate, polymerization shrinkage stress, for each material: T1 - composite resin, T2 - flowable resin e T3 - resin-modified glass-ionomer. Materials were inserted into 2mm space, between two dentin bovine cylindrical bases, (diameter 4,0mm), which one was connected a load cell. A curve ForceXTime, was obtained for each of samples. Results were analyzes by Anova and Tukey Test. (p=0,05). 3ª (Finite Elements Analysis) - In this phase, stresses resulting from polymerization shrinkage in combination with oclusal loading, were determinate in a 2D finite element model. The polymerization shrinkage stress was fundamented in Tensilometry and Phoelasticity results... (Complete abstract, click electronic access below)
369

Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendas

Souza, Niélli Caetano de [UNESP] 01 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-01Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 souza_nc_me_arafo.pdf: 1115015 bytes, checksum: 8487455e45f6d12782f7b081be948890 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique.
370

Estudo dos fotoiniciadores utilizados em resinas compostas

Alvim, Hugo Henriques [UNESP] 26 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-26Bitstream added on 2014-06-13T19:41:14Z : No. of bitstreams: 1 alvim_hh_dr_arafo.pdf: 694477 bytes, checksum: 944910958f33686fa33839611d4acf41 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar as características de diferentes fotoinciadores com potencial para serem utilizados em resinas compostas. Foram utilizadas as resinas compostas: Filtek Z250 A3 (FZA3); Filtek Z-250 Incisal (FZI); Pyramid Enamel A1 (PEA1); Piramyd Enamel Translucent (PET); Filtek Supreme A3E (FSA3) e Filtek Supreme GT (FSGT). Foram pesados 500mg de cada resina e dissolvidos em 1,0 ml de metanol. As amostras foram centrifugadas para acelerar a sedimentação das partículas inorgânicas. Foram pipetados 0,8 ml da solução sobrenadante e analisados por cromatografia gasosa acoplado ao espectrômetro de massa (GC-MS). Os resultados foram comparados a soluções de canforoquinona pura, utilizadas como padrão. O teste de T Student, (p=0,05), comparou os resultados entre as cores de cada marca comercial. Observou-se menor quantidade de canforoquinona na cor incisal da resina Filtek Z-250 (FZI) quando comparada à cor A3 (FZA3). Por outro lado, a resina Filtek Supreme apresentou quantidade de canforoquinona estatisticamente superior na cor Incisal. Na resina Pyramid Enamel foi encontrada canforoquinona apenas na cor A1, sendo que o fotoiniciador utilizado na cor Translucent não foi identificado. Baseado nos dados obtidos pode-se concluir que uma mesma marca comercial de resina composta pode apresentar diferenças na quantidade e no tipo de fotoiniciador utilizado. Em seguida investigamos a reação de polimerização de quatro compósitos experimentais por fotocalorimetria, utilizando diferentes fotoiniciadores. Esta técnica permite estimar o grau de conversão (GC) e parâmetros da cinética da reação como a aceleração da reação em tempo real. Foi elaborada uma resina composta experimental, a base de Bis-GMA (14,5% m/m), UDMA (6,5% m/m) e partículas de carga silanizadas (79% m/m). Este compósito foi dividido em quatro grupos, que receberam os seguintes fotoiniciadores:... / To identify and quantify the camphorquinone (CQ) used in different brands of composite resins as a function of the shade analyzed. Filtek Z250 A3 (FZA3), Filtek Z- 250 Incisal (FZI), Pyramid Enamel A1(PEA1), Pyramid Enamel Translucent (PET), Filtek Supreme A3E (FSA3) and Filtek Supreme GT (FSGT) were used. Five hundred milligrams of each resin were weighed and then dissolved in 1.0 ml of methanol. The samples were centrifuged to accelerate the sedimentation of the inorganic particles. 0.8 ml of the supernatant solution was collected with a pipette and assessed under gas chromatography coupled to the mass spectrometer (GC–MS). The results were compared to pure CQsolutions, used as a standard. Student’s t-test, (p = 0.05) significant at the level of 5%, compared the results of each brand shade. A smaller amount of camphorquinone was found in Filtek Z-250 (FZI) resin incisal shade when compared to (FZA3) A3 shade. On the other hand, Filtek Supreme resin featured a statistically larger camphorquinone amount in the incisal shade. In Pyramid Enamel resin camphorquinone was found only in shade A1, while the photoinitiator used in the Translucent shade was not identified. Then we investigate the reaction of polymerization of four experimental composites by fotocalorimetria, using different photoinitiators. This technique allows estimating the degree of conversion (GC) and kinetic parameters of the reaction as the acceleration of the reaction in real time. It was drawn up a composite resin experimental, the basis of Bis-GMA (14.5% m / m), UDMA (6.5% m / m) and particulate load silanizadas (79% m / m). This composite was divided into four groups, which received the following fotoiniciadores: camphorquinone (CQ), 1-phenyl-1 ,2-propanodione (PPD), MAPO (Lucirin TPO) and BAPO (Irgacure 819). The reaction of polymerization of these four experimental composite was analyzed...(Complete abstract, click electronic access below)

Page generated in 0.0925 seconds