• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 52
  • 23
  • 21
  • 20
  • 16
  • 13
  • 12
  • 11
  • 9
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

"Avaliação da profundidade de polimerização de uma resina composta, pela técnica trans-dental, utilizando-se três diferentes fontes de luz : halógena, laser de argônio e leds" /

Rastelli, Alessandra Nara de Souza. January 2002 (has links)
Resumo: O objetivo desse trabalho foi avaliar a capacidade de polimerização, através da estrutura dental, de três diferentes fontes de luz (Halógena, Laser de Argônio e LEDs), por meio do teste de microdureza. Para isto, foram confeccionados corpos-de-prova em uma matriz metálica circular contendo um orifício na porção central com 4 mm de diâmetro e 2 mm de profundidade. Utilizou-se a resina composta microhibrida Charisma (Heraeus-Kulzer), na cor A2, para a confecção dos corpos-de-prova. Cinco corpos-de-prova foram confeccionados para cada situação diferente, perfazendo um total de 140 corpos-de-prova, distribuídos em 3 grupos da seguinte maneira: GRUPO I - fonte de luz halógena utilizada pelos tempos de exposição de 20 e 40 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental; GRUPO II - fonte de luz de laser de argônio utilizada pelos tempos de exposição de 20 e 40 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental e GRUPO III - fonte de luz à base de LEDs utilizada pelos tempos de 20, 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,2 mm; 1,5 mm e 2,0 mm de faceta de estrutura dental. Após a confecção dos corpos-de-prova, estes foram armazenados em estufa a 37ºC durante 24 horas. Após o período de armazenamento, procedeu-se o teste de microdureza Vickers, realizando-se 12 impressões para a superfície de topo (voltada à fonte de luz) e 12 para a superfície de base (oposta à fonte de luz). Os dados foram submetidos à Análise Estatística de Variância (P<0,05). Os valores dos desvios padrão das medidas de microdureza foram menores do que 1% da média, indicando diferença estatisticamente significante entre quase todos os grupos. Baseados nos resultados encontrados, pudemos concluir que... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The objective of this study was evaluate the light-curing capacity, throught dental structure, of three differents light-curing device (Halogen, Argon Laser and LEDs), by microhardness testing. The specimes were made in a circular metallic mold with a of orifice in the cental portion measuring 4 mm in diameter and 2 mm in thickness. The composite resin was used the Charisma (Heraeus-Kulzer) at collor A2. Five samples was made by situation analyzed, adding up one hundred and forty samples: GROUP I - halogen light-curing device by exposure times of 20 and 40 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the structure dental facet; GROUP II - argon laser light-curing device by exposure times of 20 and 40 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the structure dental facet and GROUP III - LEDs light-curing device by exposure times of 20, 40 and 60 seconds for the thickness 0 (control group); 1,2 mm; 1,5 mm and 2,0 mm of the dental structure facet. After the polymerization procedures the specimes were stored at room temperature of 37ºC for 24 hours. After the storing, the microhardness testing was made, take effecting 12 impressions for the top surface and 12 for the botton surface. The hardness values means obtained were calculed and the statistically analised using Anova (P<0,05). According to the results, it was conclude that: 1) highest the thickness of the dental estructure face, have been a decreasing of the means values of microhardness, independent of the light-cured device utilized; 2) highest exposure times provided higher values means of the microhardness, independent of the light-cured device utilized; 3) the top surface showed the highest means values of hardness, independent of the light-cured device utilized; 4) the halogen light-cured device raised suitable... (Complete abstract, click electronic address below). / Orientador: Marcelo Ferrarezi de Andrade / Coorientador: Vanderlei Salvador Bagnato / Banca: Sillas Luiz Lordelo Duarte Júnior / Banca: João Carlos Gomes / Mestre
32

Citotoxidade direta e transdentinária de sistemas adesivos com diferentes graus de hidrofilia sobre células odontoblastóides /

Bianchi, Luciana. January 2011 (has links)
Orientador: Josimeri Hebling / Banca: Marcela Rocha de Oliveira Carrilho / Banca: Edson Alves de Campos / Resumo: O objetivo geral desse trabalho, dividido em dois experimentos (capítulos 1 e 2), foi avaliar a citotoxicidade de sistemas adesivos experimentais (SAEs), com diferentes graus de hidrofilia, e do etanol como solução de solvatação da dentina, sobre células odontoblastóides. No capítulo 1, discos de papel filtro esterilizados foram impregnados com 10 μL de cada SAE (n=22): R1, R2, R3, R4 e R5 (em ordem crescente de hidrofilia), seguido de fotoativação. Os discos foram individualmente imersos em meio de cultura DMEM para obtenção de extratos (DMEM + componentes liberados dos SAEs), os quais foram posteriormente aplicados sobre células MDPC-­‐23 em cultura. Discos não impregnados (R0) serviram como controle. Foram avaliados o metabolismo celular (teste de MTT), a expressão de proteína total (PT) e a atividade de fosfatase alcalina (FA), além do tipo de morte celular (citometria de fluxo) e grau de conversão monomérica (FTIR) dos SAEs. Os dados de cada variável resposta do estudo foram analisados por testes de Kruskal-­‐Wallis e Mann-­‐Whitney (α=0,05). Considerando R0 como 100%, foi observada redução do metabolismo celular de 36,4%, 3,1%, 0,2%, 21,5% e 65,7%, respectivamente para R1, R2, R3, R4 e R5. Apenas R1 e R5 diferiram estatisticamente do controle. Para PT, R1, R4 e R5 tiveram expressão estatisticamente inferior ao controle, enquanto que a atividade de FA foi significativamente reduzida por R1 e R5. Esses mesmos SAEs juntamente com R4 induziram as maiores porcentagens de morte... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The overall aim of this study, divided into two experiments, was to evaluate the cytotoxicity of experimental adhesive systems (EAS) with different hydrophilicity, and ethanol as a dentin solvation solution, on odontoblast-­‐like cells. In the first experiment, sterilized filter paper discs were impregnated with 10 μL of each EAS: R1, R2, R3, R4 and R5 (in increasing rank of hydrophilicity), followed by light activation. The paper discs were individually immersed in DMEM culture medium for obtaining the extracts (DMEM + released components of EAS), which were applied on MDPC-­‐23 cells in culture. Non-­‐impregnated paper discs (R0) were used as control. Cell metabolism (MTT assay), total protein expression (TP) and alkaline phosphatase activity (ALP) were assessed, in addition to the type of cell death (flow cytometry) and the degree of monomer conversion (FTIR). Data for each response variable were submitted to Kruskal-­‐Wallis and Mann-­‐Whitney tests (α=0.05). Compared to the control (100%), cell metabolism was decreased by 36.4%, 3.1%, 0.2%, 21.5% and 65.7% for R1, R2, R3, R4 and R5, respectively. However, only R1 and R5 differed from the control. R1, R4 and R5 decreased the expression of TP compared to the control, whereas only R1 and R5 significantly reduced the activity of ALP. The later EAS plus R4 caused the highest percentages of cell death by necrosis. A higher percentage of monomer conversion was detected as a function of the hydrophilicity. According to the experimental conditions, it could be... (Complete abstract click electronic access below) / Mestre
33

Análise da microfenda axial em cavidades classe V restauradas com resina composta e polimerizadas com diferentes fontes de luz. Estudo pela microscopia eletrônica de varredura /

Magnani, Cristina. January 2002 (has links)
Resumo: Um dos maiores problemas das restaurações de resinas compostas é a sua contração durante a polimerização, causando fendas entre as paredes cavitárias e o material restaurador. Assim, este trabalho teve como objetivo avaliar a influência da fonte de luz polimerizadora na formação de fendas axiais em restaurações classe V de dois tipos de resina composta. Foram utilizados 80 molares humanos, nos quais foram realizados os preparos cavitários com: 2mm de profundidade, 2mm de extensão ocluso-cervical e 2mm de extensão mésio-distal. Foram confeccionadas duas restaurações em cada dente (uma na superfície vestibular e outra na lingual) restauradas com dois tipos de resinas compostas: micropartículas (Filtek A110, cor A3 - 3M) e híbrida (Filtek P60, cor A3 - 3M); utilizando o sistema adesivo Prime & Bond NT (Dentisply), para um total de 160 amostras. Essas amostras foram divididas em 8 grupos, variando-se a fonte de luz e o tempo utilizado para a fotopolimerização do material: Grupo 1: resina micropartículas + aparelho convencional - 40s; Grupo 2: resina híbrida + aparelho convencional - 40s; Grupo 3: resina micropartículas + laser de argônio - 20s; Grupo 4: resina híbrida + laser de argônio - 20s; Grupo 5: resina micropartículas + diodo emissor de Luz (LED) azul- 40s; Grupo 6: resina híbrida + LED azul- 40s; Grupo 7: resina micropartículas + LED azul- 60s; Grupo 8: resina híbrida + LED azul- 60s. Os dentes foram armazenados em água destilada por 7 dias e submetidos à ciclagem térmica. A análise das medidas de fenda, quando presente, foi realizada através de microscopia eletrônica de varredura pela técnica de réplica, e os resultados obtidos foram submetidos a análise estatística de variância e teste de Tukey ao nível de 5% de significância. Concluiu-se que a resina de micropartículas apresenta maior contração de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: One of the greatest problems of restorations with composite resin is its contraction during light-curing, casing gaps between the cavitary walls and the restorative material. Thus, this study had as main goal to evaluate the influence of the light source light-cured on the formation of axial gaps in class V restorations of two types of composite resin. Eighty (80) human molars were used, in which cavitary preparations were accomplished with: 2mm of depth, 2mm of occlusocervical extension and 2mm of mesiodistal extension. Two restorations in each tooth were restored (one in the vestibular surface and the other on the lingual surface) with two types of composite resin: microparticles (Filtek A110, color A3 - 3M) and hybrid (Filtek P60, color A3 - 3M); using the adhesive system Prime & Bond NT (Dentisply), on a total of 160 samples. These samples were divided into eight groups, varying the light source and the time used for the material light-curing: Group 1: microparticles resin + conventional appliance - 40 s; Group 2: hybrid resin + conventional appliance - 40 s; Group 3: microparticles resin + argon laser - 20 s; Group 4: hybrid resin + argon laser - 20 s; Group 5: microparticle resin + light emitting diodes (LEDs) blue - 40 s; Group 6: hybrid resin + blue LEDs - 40 s; Group 7: microparticles resin + blue LEDs - 60 s; Group 8: hybrid resin + blue LEDs - 60 s. All teeth were storage in distilled water for 7 days and submitted to thermal cycling. The analysis of the gap measures, when present, was fulfilled by using the scanning electron microscope by the reproduction technique, and the results obtained were submitted to the statistical analysis of variance and the Tukey test to 5% significance level. It was concluded that the microparticles resin presents more light-curing contraction than the hybrid resin, independently... (Complete abstract, click electronic address below). / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Vanderlei Salvador Bagnato / Banca: Osmir Batista de Oliveira Júnior / Banca: Alberto Magno Gonçalves / Mestre
34

Influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta /

Alencar Júnior, Emmanuel Arraes de. January 2002 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: José Roberto Cury Saad / Banca: Mânio de Carvalho Tibúrcio / Resumo: O objetivo desta pesquisa foi avaliar a influência da distância de uma fonte de luz halógena na microdureza superficial da resina composta, considerando as superfícies de topo e base dos corpos-de-prova. Foram utilizadas duas marcas comerciais de resina composta, Z250 de partículas pequenas e uma resina de micropartícula, A110, ambas da 3M do Brasil Ltda. O aparelho de ativação da resina composta foi K&M 220- R, cuja intensidade de luz possui um pulso que variava após os 5 primeiros segundos assim alcançando sua intensidade máxima que foi medida em 720 mW/cm2. Para a determinação da intensidade de luz emitida pelo aparelho fotoativador, utilizou-se um radiômetro (Medidor de irradiância 150- CMC , São Carlos - SP). Corpos-de-prova foram confeccionados utilizado-se matrizes metálicas que possuíam um orifício central de 4mm de diâmetro por 2mm de espessura. As resinas foram inseridas no orifício da matriz metálica, em um único incremento, por meio de uma espátula metálica e sobre elas foi sobreposta uma tira matriz transparente de poliéster e, após isto, um peso de 1 Kg foi posto em cima da tira para que houvesse uma melhor condensação da resina composta evitando a presença de bolhas de ar, no interior do corpo-de-prova. A fonte de luz halógena foi fixada em uma mesa de maneira que a saída da ponta de luz ficasse paralela à superfície do corpo-de-prova. Para provocar o distanciamento da fonte de luz, anéis metálicos confeccionados em latão, com espessuras que variavam de 2mm, 4mm e 8mm foram utilizados, os quais, após posicionados, eram removidos para não interferiem no dispersamento da luz. As distâncias imprimidas a fonte de luz na superfície da resina foram de 0mm(tocando a superfície), 2mm, 4mm e 8mm. Para cada uma destas distâncias, a intensidade de luz foi medida. Esta variou de intensidade de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this research was to evaluate the influence of the light tip distance in the superficial microhardness of the composite resin, considering the surfaces of top and base of the samples. Two commercial composite resin marks had been used, Z250 of small particles e a microparticle resin, A110, both of 3m of Brazil Ltda. The device of activation of the composite resin was K&M 220- R, whose intensity of light possess a pulse that varied the 5 first seconds after thus reaching its maximum intensity that was measured in 720 mW/cm2. For the determination of the intensity of light emitted for the fotoativador device, a radiometer (Measuring of irradiance 150- CMC was used, Is Carlos. SP). The samples had been confectioned used first metallic that had a central orifice of 4mm of diameter for 2mm of thickness. The resins had been inserted in the orifice of the metallic array, in an only increment, by means of a metallic spatula and on them a transparent first polyester strap was overlapped and, after this, one weight of 1 kg was rank in top of the strap so that it had one better condensation of the composite resin preventing the presence of air bubbles, in the inward of the body-of-test. The source of light was fixed in a table thus the output of the light tip was parallel to the surface of the body-of-test. To provoke distance from the light source, confectioned metallic rings in brass, with thickness that varied of 2mm, 4mm and 8mm had been used, which, after located, was removed to avoid concentration of light. The printed pitches the source of light in the surface of the resin had been of 0mm(on the surface), 2mm, 4mm and 8mm. For each one of these pitches, the light intensity was measured. This varied of intensity of 720 mW/cm2 for the tip touching the surface of the body-of-test, 650 mW/cm2 for in the distance of 2mm, 600 mW/cm2... (Complete abstract, click electronic address below). / Mestre
35

Estudo da infiltração marginal em restaurações de resinas compostas para dentes posteriores : efeito de material, preparo cavitário e condicionamento do esmalte a nível cervical /

Araújo, Rosehelene Marotta. January 1989 (has links)
Orientador: Francisco Pedro Monteiro da Silva Filho / Resumo: Por muitos anos a profissão odontológica tem procurado um material estético para substituir as ligas de amálgama. Recentemente, têm aparecido no comércio as resinas compostas para dentes posteriores indicadas para restaurações onde não há incidência de forças mastigatórias. Tais resinas têm, porém, apresentado falhas, e, entre elas, a infiltração marginal, que tem enorme importância, pois é responsável pela sensibilidade pós-operatória, manchamento e ocorrência de cáries secundárias com consequentes alterações patológicas da polpa. Este trabalho teve a finalidade de estudar ''in vitro'' a infiltração marginal, a nível cervical, de restaurações classe II com as resinas posteriores quimicamente ativadas P10 e fotoativadas P30, em dois tipos de cavidades: convencional e adesiva. Foi verificado também o efeito do condicionamento ácido nesta região. A pesquisa foi realizada em dentes pré-molares recentemente extraídos por motivo ortodôntico, e para obter cavidades padronizadas os preparos foram feitos com a utilização de um microscópio modificado por GABRIELLI e cols.25 Foi utilizado adesivo dentinário (Scotchbond) em todos grupos experimentais. A infiltração foi evidenciada por meio do corante Rodamina B, após ciclagem térmica entre as temperaturas 10°C e 50°C, e analisada seguindo o critério de HIRSCH e WEINREB37, modificado, com auxílio de uma lupa estereoscópica ZEISS com 10 aumentos. Pelos resultados obtidos, pudemos verificar que: 1- Ocorreu infiltração marginal a nível cervical em 77,5% das restaurações de cavidades convencionais e em 47,5% das cavidades adesivas. 2- A maior percentagem de infiltração, independentemente dos fatores em estudo, ocorreu sempre no nível 3, ou seja, com infiltração até a parede axial. 3- Tanto a resina quimicamente ativada quanto a fotoativada permitiram a mesma infiltração. 4- O condicionamento ... / Abstract: For many years the dental profession has sought an esthetic material to replace the amalgam alloys. Recently composite resins for posterior teeth have been introduced into the marketplace. The manufacturers claimed that these materials are indicated for stress-bearing restoration. However. such resins have presented some limitations such as marginal leakage which has great clinical importance because it is responsible for postoperative sensitivity, and occurence of secundary caries followed by pathological changes of the pulp. The purpose of this ''in vitro'' study was to investigate the cervical marginal leakage in class II restorations with chemically cured resin - PlO - and light- cured resin - P30 - in two types of cavities: conventional and adhesive. The effect of acid-etching in this area was also observed. The cavities were prepared in premolar teeth, recently extracted for orthodontic purposes, using a Microscope Modified by GABRIELLI and cols.25, in order to obtain standardized cavities. Dentine adhesive (Scotchbond) was used in all experimental groups Leakage was evidenced by Rodamina B dye penetration after thermocycling procedure between 10°C and 50ºC temperature and analysed according to HIRSCH g WEINREB modified criterion by using ZEISS Stereoscopic Magnifying Glass (10x). According to the results, we should concluded that: 1- Cervical marginal leakage occurred to 77,5% of conventional cavities restorations and 47,5% of adhesives cavities. 2- The major percents of leakage, regardless the factors studied, always occurred at level 3, that is, with leakage up to axial wall. 3- Either chemically cured resin or light - cured resin presented the same leakage. 4- The acid-etching reduced from 70% to 55% the leakage percentage observed. 5- The leakage observed for adhesive or conventional cavities continued when chemically cured resin or light- cured resin was used. 6- Acid-etching... / Doutor
36

Influência do tipo de tratamento superficial na força adesiva do reparo com resina composta em materiais estéticos /

Ahid, Fernando Jorge Mendes. January 2003 (has links)
Orientador: Welingtom Dinelli / Banca: Luís Geraldo Vaz / Banca: Marcelo Ferrarezi de Andrade / Banca: Edson Alves de Campos / Banca: Paulo Sérgio Quagliatto / Resumo: Avaliou-se a influência do tipo de tratamento da superfície de materiais estéticos no processo de adesão do reparo com resina composta, por meio do teste de cisalhamento. Foram preparados 360 corpos-de-prova, sendo 120 em cerâmica, 120 em resina composta e 120 em cerômero os quais receberam 06 tipos de tratamentos de superfície a saber, ponta diamantada (GT1C), ponta diamantada e silano (GT1S), jato abrasivo (GT2C), jato abrasivo e silano (GT2S), ácido hidrofluorídrico (GT3C) e ácido hidrofluorídrico e silano (GT3S). O adesivo do Sistema Scotchbond Multipurpose Plus, silano e resina composta Z100 foram aplicados sobre a superfície e os corpos-de-prova armazenados à temperatura de 37oC, por 24 horas, ciclados e novamente armazenados, para em seguida serem cisalhados. A análise estatística dos resultados mostrou que não houve diferença estatística na resistência adesiva dos reparos em resina composta e cerômero, porém, para o material cerâmico, o silano foi eficiente para aumentar a resistência para os tratamentos mecânicos T1 e T2, entretanto, o T3, com ou sem silano, apresentou resistência maior. Os tipos de fraturas foram 100% coesiva do substrato (CS). A microscopia mostrou superfícies com características diferentes para cada material e tratamento superficial. Concluindo os valores de resistência adesiva para a cerâmica sofreram influência do tipo de tratamento e que estes não influenciaram os materiais resinosos. / Abstract: The influence of the types of the surface treatment in esthetic materials in adhesive process, was evaluaed through shear strength test. The samples were constructed and polished, that received the treatment with diamond bursh (GT1C), and silane application (GT1S), jet of abrasive air (GT2C), and silane application (GT2S), hydrofluoric acid gel (GT3C) and silane application (GT3S). The adhesive of Scotchbond Multiporpose Plus System, the silane and Z100 composite resin were applied on this surface and the whole resin/substract was stored to the temperature of 37o.C, for 24 hours. They were thermocicled, stored again and tested in tension. The static analyses of results showed there is not difference in adhesive resistence of repair between composite resin and ceromero, however in ceramic, the silane increased the resistance in T1 and T2. The T3 group silanated and non silanated was observed increase of resistance. The types of fractures that occurred were 100% cohesive. Scanning electronic microscopy analysis revealed different surfaces in differentes estetic materials and diferents types de surface treatments. The present study showed that adhesive resistence of ceramic repair were affected for the type of surface treatment. However the type of surface tratment didn't affected the adhesive resistence of other materials. / Doutor
37

Análise "in vitro" da influência de três sistemas de fotopolimerização, através da MEV, na amplitude de fendas axiais em cavidades classe V restauradas com resina composta /

Gomes, Osnara Maria Mongruel. January 2003 (has links)
Orientador: Sizenando de Toledo Porto Neto / Banca: José Pereti Neto / Banca: Rosehelene Marotta Araújo / Banca: Osmir Batista de Oliveira Júnior / Banca: Maria Salete Machado Cândido / Resumo: A contração de polimerização é ainda o maior problema das restaurações de resina composta fotopolimerizável, causando a formação de fendas marginais. O objetivo deste estudo in vitro foi avaliar a formação de fendas axiais em restaurações de resina composta classe V usando três diferentes sistemas de fotopolimerização. Cavidades padronizadas foram executadas nas faces vestibular e lingual de trinta terceiros molares humanos, com margens localizadas abaixo da junção cemento/esmalte. Resina composta foi inserida em dois incrementos usando sistema restaurador Filtek A 110 (3M) e Single Bond (3M). Resina composta foi fotopolimerizada usando três sistema de fotopolimerização: Grupo I: Quartzo tungstênio halogênio (QTH) convencional (dois incrementos com 20 seg - 600 mW/cm2 - Optilux 401 Demetron); grupo II: QTH pulso tardio (primeiro incremento com 3 seg - 200 mW/cm2 + 3 min período de espera + 20 seg - 600 mW/cm2 e segundo incremento com 20 seg - 600 mW/cm2 VIPTM Bisco); grupo III: Diodo emissor de luz azul - LEDs (dois incrementos com 20 seg- 400 mW/cm2 - EliparTMFreeLight - 3M ESPE). Em seguida, os dentes foram colocados em água destilada a 37oC durante 24 horas; e as restaurações foram polidas. Os dentes foram submetidos a ciclagem térmica por ciclos à 10oC + 2oC e 50oC + 2oC, com um tempo de permanência de 15 segundos em cada temperatura, realizando um total de 500 ciclos. Os dentes foram seccionados vestíbulo-lingualmente através de cada restauração sob constante refrigeração. A extensão da fenda entre a parede axial e o material restaurador foi observada sob MEV a 500X. Os valores médios da amplitude foram: GI 3.61 l 5.08 mm; GII 1.12 l 1.77 mm e GIII 1.46 l 2.73 mm. Os dados foram analisados através do teste não paramétrico de Kruskal-Wallis e o teste de comparações múltiplas de Dunn, onde o grupo II... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: Polymerization shrinkage causing marginal gap formation is still a major problem in light curing restorations. The aim of this in vitro study was evaluate the gap formation in axial wall of class V resin composite restorations using three different photocuring technique. Standard cavities were prepared on the buccal and lingual surfaces of 30 human third molars with margins located below the cemento-enamel junction. Resin was inserted in two increments using the restorative system Filtek A110 (3M) and Single Bond (3M). Resin composite were photocured using three polymerization techniques: Group I: Quartz tungsten halogen (QTH) convencional (two increments with 20 sec - 600 mW/cm2 - Optilux 401 Demetron); group II: QTH pulse delay (first increment with 3 sec - 200 mW/cm2 + 3 min waiting period + 20 sec - 600 mW/cm2 and second increment with 20 sec - 600 mW/cm2 VIPTM Bisco); group III: light emitting diode (LEDs) two increments with 20 sec - 400 mW/cm2 - EliparTM FreeLight 3M-ESPE). Before finish and polishing, samples were stored in destiled water at 37ºC for 24 hours. The teeth were termocycled for 500 cycles (10º C l 2º C and 50º C l 2º C) with a dwell time of 15 seconds. The teeth were sectioned buccolingually through each restoration under constant refrigeration. The extend of gaps between the axial dentine wall and the restorative material was assessed under SEM at X500. Results: the mean and range values were as follows: GI 3.61 l 5.08 mm; GII 1.12 l 1.77 mm and GIII 1.46 l 2.73 mm. The data were analyzed by Kruskal-Wallis and Dunn Tests. Group II showed lower values, followed by group III and group I. Group I showed higher values of gaps. Gaps were observed in all groups. Among polymerization technique used in the study, the group II presented the best performance. / Doutor
38

Avaliação da resistência ao desgaste de uma resina composta odontológica nanoparticulada empregando diferentes tempos de fotopolimerização /

Souza, Celso Naves de. January 2009 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Edson Cocchieri Botelho / Banca: Carlos Roberto Grandini / Banca: Sandra Giacomin Schneider / Banca: Sergio Scheneider / Resumo: Este trabalho tem como objetivo avaliar a influência dos tempos de fotopolimerização nas resinas odontológicas, onde quatro resinas compostas foram utilizadas, sendo três micro híbridas e uma nanoparticulada. Esses compósitos foram submetidos ao desgaste abrasivo de esfera rotativa pelo método de ball cratering. Para tal ação foi projetado e construído um dispositivo de desgaste por micro abrasão de esfera rotativa livre de três corpos. Os corpos de prova foram confeccionados e embutidos em uma matriz de alumínio, com uma profundidade de 2mm. Usam-se o aparelho LED RADII, com os tempos de exposição de 20, 30 e 40 segundos e uma esfera com 15 mm de diâmetro de aço temperada, retificada e revenida. A lama abrasiva utilizada nesse estudo foi uma solução composta por 20% de talco (USP/200) e 80% de soro fisiológico, na quantidade de 3 gotas por segundo. Para comprovação dos resultados obtidos, utilizaram-se os testes de: Espectroscopia por Dispersão de Energia (EDS), Infravermelho por Transformada de Fourier (FT-IR), Análise Termogravimétrica (TGA), micro dureza Vickers, ensaio de desgaste de micro abrasão por esfera rotativa pelo método de ball cratering e a análise da superfície desgastada por Microscopia Eletrônica de Varredura (MEV). Esta análise foi realizada para verificar o real mecanismo de desgaste ocorrido. Os resultados obtidos comprovam que o tempo recomendado pelos fabricantes, tem a capacidade suficiente de fotopolimerizar toda a matriz orgânica, comprovaram também que a resina nanoparticulada obteve em todos os ensaios os melhores resultados em relação às resinas híbridas, e que a cultura do acréscimo de até 20s além do recomendado não tem influência direta em relação ao desgaste abrasivo. / Abstract: This work has as an objective to evaluate the influence of photopolymerization in odontological resins, where composed four resins were used, being three of them micro hybrid and one nanoparticulated. These composites were submitted to abrasive wear and tear of rotative sphere by the method ball cratering. For such action a device of micro abrasion of rotative sphere was designed and built free of three bodies. The bodies of proof were produced and put in a matrix of aluminum with a depth of 2mm. The device used was a LED RADII, with exposition time of 20, 30 and 40 seconds and a sphere of 15mm diameter made of tempered steel, rectified and soften, the abrasive lama used in this study was a solution composed by 20% of powder (USP/200) and 80% of physiological serum released at 3 drops per second. For verification of the results obtained the tests of Energy Dispersion Spectrograph (EDS) was used, transformed Infra red of Fourier (FT-IR), Thermogravimetric Analysis (TGA) Vickers micro hardness, wear and tear of micro abrasion by rotative sphere by the method ball cratering and the analysis of worn superficies by Sweeping Electronic Microscopy (SEM). This analysis was carried out to verify the real mechanism of the worn occurred. The results obtained prove that the time recommended by the manufacturer has enough capacity to photopolymerized all the organic matrix, it also proved that the resin nanoparticulated obtained in all the essays the best results in what concerns to the hybrid resins. And the culture of the addition of 20 seconds besides what is recommended has no direct influence in relation to the abrasive wear and tear. / Doutor
39

Estudo da dureza e da resistência à compressão de resinas compostas para dentes posteriores após a imersão em água destilada. Efeito da aplicação de selante superficial /

Cruz, Carlos Alberto dos Santos. January 2001 (has links)
Resumo: Novos compósitos têm surgido no mercado especificamente destinados à confecção de restaurações estéticas posteriores. Entretanto, embora tais materiais apresentem resultados iniciais animadores, há a necessidade de comprovações adicionais para que possam ser utilizados com segurança. Resinas compostas posteriores são submetidas a estresses complexos de compressão e abrasão durante a mastigação e a aplicação de selantes superficiais tem sido relatada como forma de aumentar a resistência ao desgaste destes materiais. O presente trabalho teve como propósito avaliar a dureza e a resistência à compressão das resinas compostas Alert (Jeneric/Pentron), Ariston (Vivadent), Definite (Degussa), P60 (3M), Solitarie (Kulzer), Surefil (Dentsply) e Z100 (3M) após 90 dias de imersão em água destilada, recobertas com selante Protect It (Jeneric/Pentron) e submetidas à ciclagem mecânica (10.000 ciclos, 600N, 5Hz). Os ensaios de dureza (n=8) foram realizados em aparelho Wolpert, com diamante Vickers e peso de 50gf aplicado por 30 segundos, antes e após períodos de imersão de 30, 60 e 90 dias. Os ensaios de resistência à compressão (n=8) foram realizados somente após 90 dias, em corpos-de-prova cilíndricos medindo 8mm de altura por 4mm de diâmetro. Apenas os espécimes destinados à compressão foram ciclados mecanicamente. Os ensaios foram realizados em máquina MTS 810, equipada com célula de carga de 10kN (ciclagem) e 100kN (compressão) e velocidade de 0,5mm/min. Após análise de variância (p<0,05), os resultados mostraram, previamente à imersão, maiores valores de dureza para os materiais Z100 (74,253VHN) e Ariston (71,308VHN). A seguir, com valor semelhante à resina Ariston, mas inferior à resina Z100, apresentou-se o material Surefil (69,969VHN)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: New materials have been specifically indicated to direct posterior esthetic restoration. Although the clinical results seem to be satisfactory, at first, they haven't been enough to warrant restoration longevity. Posterior composite resins are subjected to compressive and abrasive stresses and surface penetrating sealants have been indicated in order to increase resins' wear resistance. The aim of this study was to evaluate hardness and compressive strength of posterior composite resins (Alert/Jeneric-Pentron, Ariston/Vivadent, Definite/Degussa, P60/3M, Solitarie/Kulzer, Surefil/Dentsply and Z100/3M), treated with a surface sealant (Protect It/Jeneric-Pentron), after 90 days of destiled water immersion and subjected at 10,000 stress cycles (600N, 5Hz). The hardness tests (n=8) were conducted on Wolpert equipment, using a Wickers diamond and 50gf load applied for 30 seconds before and after immersion for 30, 60 and 90 days. The compressive tests (n=8) were conducted after 90 days on MTS-810 machine with load cell of 10kN (cycling) and 100kN (compressive strength) and crosshead speed of 0.5 mm/min in samples 4mm of diameter and 8mm height. Before immersion (Anova, p<0,05), Z100 (74.253VHN) and Ariston (71.308VHN) showed the highest hardness. Surefil (69.969VHN) was similar to Ariston, but significantly lower than Z100. Alert (66.138VHN) was lower than Surefil, but higher than P60 (62.833VHN) and Definite (61.302VHN). Solitaire (46.609VHN) exhibited the lower hardness. After immersion, there was a significant decrease in hardness for almost all materials (Ariston, 97%; Definite, Solitaire and Surefil, 26%; Z100, 12% and Alert, 8%). Surface penetrating sealant had no effect on hardness values. Without cyclic loading (Anova, p<0,05), Z100 (336.275MPa), Alert (334.350MPa), P60 (331.000MPa)... (Complete abstract, click electronic access below)
40

Análise "in vitro" da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras /

Calixto, Abraham Lincoln. January 2003 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Paulo Sergio Quagliato / Banca: João Carlos Gomes / Resumo: O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below) / Doutor

Page generated in 0.0958 seconds