• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Estudo do comportamento de pavimentos de concreto simples em condições de aderência entre placa de concreto e base cimentada ou asfáltica. / Study of concrete pavement behavior in bonding condition between concrete slab and cemented or asphalt base.

Pereira, Deividi da Silva 31 July 2003 (has links)
Motivado pela alteração do sistema construtivo de pavimentos de concreto de cimento Portland, na qual foi abolida a utilização da manta plástica entre placas e bases cimentadas, com conseqüente emprego de imprimação da base com emulsão asfáltica, este trabalho buscou responder algumas indagações surgidas durante este processo. Em laboratório, através de uma metodologia de ensaio especialmente adaptada para o estudo da resistência ao cisalhamento entre concreto de cimento Portland (CCP) e concreto compactado com rolo (CCR), inferiu-se, para diferentes tratamentos de interface, elevados níveis de resistência ao cisalhamento em interfaces sem emulsão asfáltica que potencializam o emprego de estruturas monolíticas de pavimentos. Quanto àquelas que continham material asfáltico, foram obtidos resultados muito inferiores aos anteriores, com caracterização de ruptura dúctil, por efeito de fluência do material betuminoso. Duas pistas experimentais instrumentadas, uma em whitetopping ultradelgado e outra em pavimento simples de concreto executado segundo a nova prática construtiva, capazes de mensurar as deformações específicas do CCP durante a execução de provas de carga dinâmica, associadas às modelagens por elementos finitos (MEF), realizadas com auxílio do programa ISLAB2000, propiciaram importantes inferências sobre o comportamento mecânico destes dois tipos de pavimentos de concreto. Verificou-se o trabalho mecânico composto (monolítico) das estruturas de whitetopping ultradelgado, com boas correlações entre as tensões medidas e numericamente calculadas; e entre os rebaixamentos da linha neutra (LN) determinados analítica, numérica e experimentalmente. No tocante ao pavimento simples de concreto sobreposto à base cimentada imprimada, apesar das ótimas correlações entre tensões medidas e determinadas numericamente, não se pode obter conclusões definitivas a despeito do trabalho mecânico desta estrutura, apesar da existência de indícios de comportamento não-monolítico. / This thesis intended to answer some inquiries, which arose during the alteration of the concrete pavement constructive process. This process substituted the plastic blanket by the asphalt emulsion, between the concrete slabs and the cemented bases. A laboratorial test methodology, specially adapted for the study of shear strength between the Portland cement concrete and the rolled concrete, inferred, for different types of interlayer treatments, high levels of shear strength, at the interfaces without asphalt emulsion. These shear strength levels enable the monolithic behavior of the pavement structure. When the asphalt emulsion was presented at the interlayer, the shear strength was much smaller than the former, with ductile rupture due to creep of the bituminous material. Two instrumented road tests, the first section in ultra-thin whitetopping pavement and de second one, in jointed plain concrete pavement (built according to new constructive process), and the finite element analyses led to important conclusions about the mechanical behavior of these pavement structures. This was possible because the strain-gages measured the specific concrete deformations during the dynamic load tests. The monolithic behavior of the ultra-thin whitetopping pavement was verified. There were good correlations between the measured stresses and theoretical stresses, which were calculated by the finite element method; and between the neutral axle displacements, estimated by analytical, numerical and experimental methods. With regard to the jointed plain concrete pavement, which was built over the cemented base (covered by the asphalt emulsion), great correlations between measured and simulated stresses were found, as well as it was found for ultra-thin whitetopping. However, it was not possible to conclude, definitively, concerning the mechanical behavior of this pavement structure, although there are clues that ndicated a non-monolithic behavior, that is, concrete slabs are unbounded up with the cemented base.
212

Efeito da radioterapia na adesão e interface ao substrato de dentes permanentes / Effect of radiotherapy on bonding and bonding interface to substrate of permanent teeth

Arid, Juliana 27 November 2015 (has links)
O câncer de cabeça e pescoço é, dentre todos os tipos de cânceres, o sétimo mais comum, dentre suas principais formas de tratamento está a radioterapia (RT), que é amplamente utilizada e eficiente, mas os efeitos colaterais aos tecidos adjacentes são inevitáveis. A realização do tratamento odontológico previamente a radioterapia é de suma importância e visa eliminar/reduzir os focos infecciosos presentes na cavidade bucal, sendo essencial a eliminação das lesões de cárie, e após a radioterapia é fundamental tratar as \"cáries de radiação\", que é um dos efeitos colaterais do tratamento radioterápico de cabeça e pescoço. Os sistemas resinosos são os materiais mais indicados para restauração dos dentes de pacientes submetidos à radioterapia, por isso o objetivo do presente estudo foi avaliar in vitro o efeito da radiação, no momento em que é realizada a restauração ao esmalte e a dentina, por meio de teste de cisalhamento, analisar longitudinalmente as alterações morfológicas na superfície do substrato dental durante a radiação por meio de microscopia confocal a laser e analisar qualitativamente a interface de união compósito/substrato dental por meio de microscopia eletrônica de varredura (MEV). Foram utilizados 60 terceiros molares permanentes, que foram seccionados em um total de 120 fragmentos de esmalte e 120 de dentina, e após o preparo da superfície foram divididos aleatoriamente em grupos 4 grupos (n=30): G1 (controle) - substrato sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT; G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo empregado no subgrupo \"A\" (SGA) o adesivo AdperTM Single Bond 2 (SB); e no subgrupo \"B\" (SGB) o adesivo Clearfil SE Bond (CL), para o procedimento restaurador. Os espécimes foram irradiados com fração de dose de 2Gy, 5 dias consecutivos, até atingirem a dose total de 60Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentam 4mm de altura e 2mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento e depois analisou-se o modo de fratura. Foram selecionados 5 espécimes de cada substrato, para a realização da análise morfológica da superfície dental por meio da microscopia confocal, sendo estes avaliados a cada 10Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para realização da MEV. O sistema adesivo CL apresentou desempenho superior, em ambos substratos, quando comparado o SB; quanto ao tempo da restauração, tanto em esmalte quanto em dentina, o grupo 2 apresentou os menores valores; o padrão de fratura predominante para todos os grupos foi a Adesiva; houveram alterações morfológicas notáveis em esmalte e dentina após a dose acumulativa de 30Gy, onde aos 60Gy, no esmalte, os prismas se tornaram amorfos e a camada interprismática degradada, e na dentina os túbulos dentinários encontravam-se completamente obliterados; na análise da interface adesiva do grupo 2 notou-se que quase não houve formação de tags e nos grupos 3 de esmalte a camada adesiva formada era mais fina, porém com formação de tags mais prolongados e na dentina houve formação de gaps. / Head and neck cancer is among all kinds of cancer the seventh most common and radiotherapy (RT) is one of its main treatments, which is widely used and efficient, but side effects are unavoidable. A dental treatment before RT is very important to reduce/eliminate infectious foci in the oral cavity, so it is essential to eliminate carious lesions, and after RT \"radiation caries\", which are a side effect of the treatment, must be eliminated. Adhesive systems are the most indicated to restore teeth of patients undergoing RT, so this study aimed to evaluate in vitro the effect of RT in the moment of the dental restorations in enamel and dentin, using shear bond strength tests, evaluate morphologic alterations at teeth surface during RT, with a laser confocal microscopy and to evaluate qualitatively the union interface of the composite/ dental substrate by scanning electron microscope (SEM). It was used 60 third molars, which were sectioned into 120 fragments of enamel and 120 of dentin, and after the surface prepare the specimens were randomly divided into 4 groups (n=30): G1 (control) - no irradiated substrate + restorative procedure; G2 - restorative procedure performed before RT; G3 - restorative procedure performed after RT; e G4 - restorative procedure performed 6 months after RT. Each group was divided into 2 subgroups: Subgroup \"A\" (SGA) in which was used the AdperTM Single Bond 2 (SB); and subgrup \"B\" in which was used Clearfil SE Bond (CL), for the restorative procedure. The specimens were fractionally irradiated by a dose of 2Gy/day, 5 consecutive days, until it reached a total dose of 60Gy, in a total of 30 fractions, lasting 6 weeks. For the restorative treatment the resin Z350 was chosen, and for standardization it was used a matrix so all specimens had 4mm height and 2mm in diameter. The specimens were submitted to shear bond strength test and the fracture pattern was evaluated. It was chosen 5 specimens of each substrate for the morfological evaluation of the dental surface by a laser confocal microscopy, those were evaluate every 10Gy. To evaluate the adhesive interface it was chosen 3 specimens of each group and those were prepared for the SEM. A better performance was observed for the CL, in both dental substrates, rather than the SB; according to the period of restoration, in both enamel and dentin, Group 2 has showed lower values; the predominant fracture pattern to all groups was the Adesive one; there were morphological alterations in enamel and dentin after a cumulative dose of 30Gy, the prisms of enamel became formless and the interprismatic region was degraded after 60Gy, at the dentin the dental tubules were completely amorphous; the analysis of the interface adhesion has showed that in group 2 tags were barely formed, and in group 3 of enamel the adhesive layer was thinner, but tags were longer, and at the dentin gaps were observed.
213

Estudo sobre a resistência ao cisalhamento de um solo residual compactado não saturado. / Study on the shear strength of a residual unsaturated soil.

Oliveira, Orlando Martini de 22 June 2004 (has links)
O principal enfoque deste estudo é investigar alguns aspectos da resistência ao cisalhamento e as propriedades de retenção de água de um solo residual compactado no estado não saturado. Foi utilizado um solo residual de gnaisse retirado do campo experimental de geotecnia da Universidade de São Paulo. Com base na curva de compactação foram escolhidos três pontos de moldagem para o estudo, estando os mesmos associados à umidade ótima, ao ramo seco e ao ramo úmido. Foram realizadas algumas series de ensaios triaxiais sob condições saturadas (CAU e CD), e um grande número de ensaios triaxiais não saturados com teor de umidade constante (CW). Os ensaios triaxiais CW não saturados, foram feitos com medição de sucção utilizando um tensiômetro de alta capacidade (TAC) colocado na base do corpo de prova. Estudos específicos relacionados com a técnica de medição de sucção com o uso do TAC foram feitos. Com os resultados dos ensaios de resistência foram obtidas, para diferentes pressões confinantes, as variações dos valores da resistência ao cisalhamento (q) em função da sucção. Estas relações permitiram a definição das superfícies de ruptura para as três condições de moldagem. Foram investigados também aspectos relativos à forma de carregamento, a velocidade de carregamento, o tipo de compactação e a trajetória de umedecimento. São apresentados detalhes de como a resistência do solo é afetada por estas variáveis. O estudo define os procedimentos para obtenção das superfícies de resistência do solo no estado não saturado, com o uso de ensaios de compressão simples, feitos com medição de sucção durante o ensaio, e com a envoltória do solo saturado. As curvas de retenção do solo foram obtidas sob diversas condições de moldagem e umedecimento, e utilizado as técnicas de translação de eixos, placa de sucção, tensiômetro e papel filtro. Estas curvas foram utilizadas como ferramenta para se verificar a aplicabilidade dos modelos de previsão de resistência propostos por Vanapalli et al (1996) e Khalili e Khabbaz (1998), ao solo estudado. / The main focus of this study is to investigate some aspects of the shear strength and water retention properties of a compacted residual soil, under unsaturated condition. A residual of gneiss obtained from the geotechnical experimental site of the University of São Paulo was used. Based on the compaction curve three molding conditions were adopted for the study: one associated with the optimum water content, and two others located at the dry side and wet side of the compaction curve. A series of triaxial tests were performed under saturated conditions (CAU and CD), and a great number of triaxial tests under unsaturated conditions at constant water content (CW). The CW tests were performed with suction measurement using a high capacity tensiometer (HCT) placed at the base of the sample. Investigations were carried out associated with the use of the CHT. Based on the shear strength tests performed under different confining pressure the relation between shear strength and suction were determined. With this relation it was possible to define the shear surface for the three molding conditions. It were also investigated aspects related with type of loading, speed of the test, type of compaction and moisture path after compaction. It is presented details on how the shear strength is affected by these parameters. The study defines a procedure to obtain the shear surface of an unsaturated soil using unconfining tests, with suction measurement and using the shear envelope obtained at saturated condition. The retention curves were obtained at different molding conditions, following distinct moisture path. The retention curves were determined using axis translation technique, suction plate, filter paper and tensiometer. The retention curves were used as a tool to evaluate the applicability of the models presented by Vanapalli et al (1996) and Khalili and Khabbaz (1998) to infer the shear strength of the residual soil studied.
214

Propriedades física e adesiva do esmalte dental após radioterapia e colagem de bráquetes ortodônticos / Physical and adhesive properties of dental enamel after radiotherapy and bonding orthodontic brackets

Santin, Gabriela Cristina 01 December 2014 (has links)
O objetivo deste trabalho foi avaliar as propriedades físicas e adesivas do esmalte dental após radioterapia e colagem de bráquetes ortodônticos metálicos e cerâmicos. O estudo foi dividido em duas etapas. Na primeira, foram utilizados 10 molares permanentes humanos hígidos, que foram seccionados em fragmentos de esmalte de 1 mm² e divididos entre grupo irradiado e não irradiado, de forma pareada. O grupo irradiado foi submetido à radiação ionizante, com uma dose total de 60 Gy, 2 Gy/dia, durante seis semanas, com intervalo de dois dias entre às semana. Os fragmentos de esmalte dental foram submetidos a teste mecânicos de microcisalhamento para verificar se a radioterapia alterou a resistência coesiva do esmalte dental irradiado. A segunda etapa deste estudo utilizou-se de 90 pré-molares humanos hígidos e devidamente preparados, divididos em seis grupos/subgrupos (n=15): G1 - dentes não irradiados e não envelhecidos; G2 - dentes não irradiados e envelhecidos; G3 - dentes irradiados e envelhecidos; Subgrupos: bráquetes metálicos (M) e bráquetes cerâmicos (C). Os grupos G2 e G3 foram submetidos à envelhecimento artificial acelerado por meio de termociclagem, simulando o período aproximado de 1 a 2 anos, tempo esse indicado para o início de tratamento ortodôntico em pacientes pós radioterapia. Em seguida, os grupos G2 e G3 foram submetidos à radioterapia, conforme descrito. Finalizado o ciclo radioterápico, os bráquetes foram colados no esmalte dental dos espécimes com compósito Transbond XT, sendo o bráquete metálico Morelli e cerâmico Radiance. Após 24 horas, os corpos de prova foram submetidos à teste mecânico de cisalhamento e a superfície do esmalte avaliada em microscopia confocal de varredura à laser (MCVL) avaliando o índice de remanescente adesivo (IRA) e modo de fratura. Em seguida, quatro corpos de prova que apresentaram fratura do tipo coesiva de cada grupo/subgrupos foram devidamente preparados e a interface compósito/esmalte avaliada em MCVL e microscopia eletrônica de varredura. Os fragmentos de esmalte dental submetidos à radiação apresentaram menores valores de resistência ao cisalhamento do que o esmalte dental não irradiado (p<0,05). Levando em consideração a interação dos fatores dos espécimes submetidos ao teste de cisalhamento, os grupo/subgrupos submetidos à radiação e colados bráquetes cerâmicos, apresentaram menores valores de resistência. Os grupos não submetidos à irradiação, G1-M e G2-M, apresentaram com maior frequência IRA escore 0 (sem compósito na superfície), enquanto, os grupos G1-C, G2-C, G3-M e G3-C apresentaram mais de 50% de compósito aderido à superfície Quanto ao modo de fratura, os grupos controle apresentaram em sua maioria os tipos de fratura adesiva (Ad) e coesiva resina (CR), independente do tipo de bráquete Os bráquetes metálicos colados em esmalte dental submetidos à irradiação apresentaram fratura do tipo mista coesiva resina/adesiva (CR/Ad), enquanto os bráquetes cerâmicos resultaram em fraturas coesiva resina (CR) e coesiva resina/adesiva (CR/Ad). Nas imagens obtidas da região de interface compósito/esmalte, observou-se que os tags de resina foram mais extensos no esmalte dental irradiado, circundando os prismas de esmalte. Assim, conclui-se que a radiação diminuiu a resistência coesiva do esmalte dental e que os espécimes submetidos à radioterapia apresentaram maior falha adesiva entre bráquete/compósito e tags de resina mais extensos e profundos quando comparados ao grupo controle / The objective of this study was to evaluate the physical and adhesive properties of the enamel after radiotherapy and bonding of metal and ceramic orthodontic brackets. The study was divided into two stages. In the first one, 10 human permanent molars, which were cut into fragments of enamel 1 mm² and divided between irradiated and non-irradiated group, in a paired form. The irradiated group was subjected to ionizing radiation, with a total dose of 60 Gy, 2 Gy / day for six weeks, with an interval of two days between the weeks. The enamel fragments were subjected to mechanical testing to verify that microshear radiotherapy changed cohesive strength of the irradiated enamel. In The second phase of this study, was used 90 healthy and properly prepared human premolars,divided into six groups / subgroups (n = 15): G1 - non-irradiated teeth and not aged; G2 teeth unirradiated and aged; G3 - irradiated and aged teeth; Subgroups: metallic brackets (M) and ceramic brackets (C). G2 and G3 were subjected to accelerated artificial aging by thermal cycling, simulating period of approximately 1 to 2 years, this time indicated for the beginning of orthodontic treatment in post radiotherapy patients. Then the G2 and G3 groups underwent radiotherapy as described. After the radiotherapy cycle, the brackets were bonded on the enamel specimens with Transbond XT, and the metallic and Morelli ceramic bracket Radiance. After 24 hours, the specimens were subjected to mechanical shear test and evaluated the enamel surface in confocal laser scanning microscopy (CLSM) evaluating the adhesive remnant index (ARI) and fracture mode. Then four specimens showed that the cohesive fracture type were properly prepared for each group / subgroup and the composite interface / enamel evaluated CLSM and scanning electron microscopy. Fragments enamel subjected to radiation had significantly lower shear strength than the non-irradiated enamel (p <0.05). Considering the interaction of the factors of the specimens subjected to shear stress, the group / subgroup undergoing radiation and bonded ceramic brackets showed lower resistance values. The two groups were subjected to irradiation, G1 and G2-M-M, showed more IRA frequency scores of 0 (no composite surface), while the C-G1, G2, C, G3 and G3-M-C groups had more 50% of adhesive left on the surface Concerning the fracture mode, the control groups showed mostly the types of adhesive fracture (Ad) and cohesive resin (CR), regardless of the bracket\'s metal brackets bonded submitted to enamel irradiation, that showed mixed type of cohesive resin / adhesive (CR / Ad) fracture, while ceramic brackets resulted in cohesive fractures resin (CR) and cohesive resin / adhesive (CR / Ad). In images obtained from the composite region / enamel interface, it was observed that the resin tags were more extensive in the irradiated tooth enamel surrounding the enamel prisms. Thus, it is concluded that radiation decreased the tensile strength of the enamel and the specimens treated with radiotherapy had higher adhesive failure between bracket / composite and tags of more extensive and deep resin, compared to the control group
215

Adesão de diferentes sistemas adesivos ao esmalte e à dentina de dentes decíduos submetidos à radioterapia / Adhesion of different adhesive systems to the enamel and dentin of primary teeth that have undergone radiotherapy

Talitha de Siqueira Mellara 06 December 2016 (has links)
A radioterapia (RT), quando aplicada na região de cabeça e pescoço, pode ocasionar alterações estruturais no esmalte e na dentina que poderiam influenciar o comportamento dos sistemas adesivos. O presente estudo teve como objetivo avaliar a influência da RT na adesão dos sistemas adesivos (Clearfil SE Bond e Adper&trade; Single Bond 2) ao esmalte (E) e à dentina (D) de dentes decíduos, em diferentes tempos (antes e após a RT). Foram utilizados 60 molares decíduos seccionados obtendo um total de 120 fragmentos de esmalte e 120 de dentina que, após o preparo da superfície, foram divididos aleatoriamente em 4 grupos (n=30/grupo): G1 (controle) - esmalte/dentina sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT, G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo no subgrupo A empregado o sistema adesivo etch-rinse Adper&trade; Single Bond 2; e no subgrupo B o adesivo self-etch Clearfil SE Bond. Os espécimes foram irradiados com fração de dose de 2 Gy, por 5 dias consecutivos, até atingir a dose total de 60 Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentasse 4 mm de altura e 2 mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento (célula de carga 50 kgf e velocidade 0,5 mm/minuto) obtendo-se o resultado em N, o qual foi transformado em MPa. A análise do padrão de fratura foi realizada em microscopia confocal (MC). Foram selecionados 5 espécimes de esmalte e 5 espécimes de dentina, para realização da análise morfológica da superfície dental por meio de microscopia confocal, sendo estes avaliados a cada 10 Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para análise em microscopia eletrônica de varredura (MEV). O esmalte e a dentina foram analisados separadamente, sendo os dados analisados por ANOVA a 2 critérios e pós- teste de tukey (p<0,05). O nível de significância adotado foi 5%. Pode-se observar que, para ambos os substratos, o Clearfil SE Bond (E: 20,19 MPa; D: 17,61 MPa) apresentou adesão estatisticamente superior ao Single Bond (E: 17,21 MPa; D: 15,45 MPa) (p<0,05). Quanto ao momento da realização da restauração, tanto no esmalte quanto na dentina, o grupo 2 apresentou os menores valores. Na comparação fator irradiação observou-se que a irradiação afetou negativamente a adesão do esmalte e da dentina (p<0,05), no entanto no grupo 4 não observou-se alteração (p>0,05). O tipo de fratura predominante foi adesiva, que aumentou a predominância com a irradiação. Na análise em MC houve alterações morfológicas em esmalte e dentina após a dose cumulativa de 40 Gy. Em MEV observou-se a alterações na formação de tags e de camada híbrida. Pôde-se concluir que a radioterapia alterou a morfologia da superfície do esmalte e da dentina, e afetou a adesão dos sistemas adesivos, sendo necessário esperar pelo menos 6 meses para a realização dos procedimentos restauradores, tendo o sistema Clearfil SE Bond menos influenciado. / When radiotherapy (RT) is performed in the head and neck region, it could lead to structural alteration in enamel and dentin that could influence the behavior of the bonding agents. The present study aimed to evaluate whether the RT interferes in the bonding o two adhesive systems (Clearfil SE Bond e AdperTM Single Bond 2) to enamel (E) and dentin (D) of primary teeth, in different times (before and after RT). Sixty primary molars were cut in a total of 120 fragments of enamel and 120 of dentin, which after the surface polishing were randomly divided into 4 groups (n=30/group): G1 (control) - enamel and dentin without RT + restorative procedures; G2 - restorative procedures performed before RT; G3 - restorative procedures performed after RT; and G4 - restorative procedures performed 6 months after RT. Each one of the groups was then divided into 2 subgroups: subgroup A using the etch-rinse Adper&trade; Single Bond 2; and subgroup B using the self-etch Clearfil SE Bond. The specimens were irradiated in dose fractions of 2 Gy, for 5 consecutive days, until reaching the final dose of 60Gy, in a total of 30 fractions, during 6 weeks. The restorative procedures were done using the Z350 composite, and for standardization of the restorations a matrix was used, so the specimens all presented 4 mm height and 2 mm of diameter. The specimens were submitted to the shear bond strength test (load of 50 kgf and speed of 0.5 mm/minute), the result was obtained in N and then transformed to Mpa. The fracture pattern was analyzed in a confocal microscopy (MC). Five specimens of enamel and 5 of dentin were chosen to the morphological analyzes also by MC, those specimens were evaluated every 10 Gy. As for the bonding interface 3 specimens of each group were chosen, and prepared for scanning electron microscopy (SEM). Enamel and dentin were evaluated separately, data was analyzed by the ANOVA and Post Test Tukey (p<0.05). Significance level was 5%. It could be observed that for both substrates the Clearfil SE Bond (E: 20.19 MPa; D: 17.61 MPa) was statically superior than Single Bond (E: 17.21 MPa; D: 15.45 MPa) (p<0.05). As for the time of restoration, group 2 had the worst results, in both enamel and dentin. It was observed that that radiation affected negatively the bonding in enamel and dentin (p<0.05), however, in the group 4 no alterations were observed (p<0.05). The predominant fracture pattern was the adhesive, which had raised its prevalence according to the radiation. In the MC analyses there were morphological alteration in enamel and dentin after the cumulative doses of 40 Gy. It was observed, by SEM, tags formations and alterations on the hybrid layer. It could be concluded that RT had affected the morphological surface of enamel and dentin, and that it affected the adhesion of the bonding systems, indicating that it should be waited at least 6 months after RT to perform restorative procedures, in which the Clearfil SE Bond was less affected.
216

Efeito da radioterapia na adesão e interface ao substrato de dentes permanentes / Effect of radiotherapy on bonding and bonding interface to substrate of permanent teeth

Juliana Arid 27 November 2015 (has links)
O câncer de cabeça e pescoço é, dentre todos os tipos de cânceres, o sétimo mais comum, dentre suas principais formas de tratamento está a radioterapia (RT), que é amplamente utilizada e eficiente, mas os efeitos colaterais aos tecidos adjacentes são inevitáveis. A realização do tratamento odontológico previamente a radioterapia é de suma importância e visa eliminar/reduzir os focos infecciosos presentes na cavidade bucal, sendo essencial a eliminação das lesões de cárie, e após a radioterapia é fundamental tratar as \"cáries de radiação\", que é um dos efeitos colaterais do tratamento radioterápico de cabeça e pescoço. Os sistemas resinosos são os materiais mais indicados para restauração dos dentes de pacientes submetidos à radioterapia, por isso o objetivo do presente estudo foi avaliar in vitro o efeito da radiação, no momento em que é realizada a restauração ao esmalte e a dentina, por meio de teste de cisalhamento, analisar longitudinalmente as alterações morfológicas na superfície do substrato dental durante a radiação por meio de microscopia confocal a laser e analisar qualitativamente a interface de união compósito/substrato dental por meio de microscopia eletrônica de varredura (MEV). Foram utilizados 60 terceiros molares permanentes, que foram seccionados em um total de 120 fragmentos de esmalte e 120 de dentina, e após o preparo da superfície foram divididos aleatoriamente em grupos 4 grupos (n=30): G1 (controle) - substrato sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT; G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo empregado no subgrupo \"A\" (SGA) o adesivo AdperTM Single Bond 2 (SB); e no subgrupo \"B\" (SGB) o adesivo Clearfil SE Bond (CL), para o procedimento restaurador. Os espécimes foram irradiados com fração de dose de 2Gy, 5 dias consecutivos, até atingirem a dose total de 60Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentam 4mm de altura e 2mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento e depois analisou-se o modo de fratura. Foram selecionados 5 espécimes de cada substrato, para a realização da análise morfológica da superfície dental por meio da microscopia confocal, sendo estes avaliados a cada 10Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para realização da MEV. O sistema adesivo CL apresentou desempenho superior, em ambos substratos, quando comparado o SB; quanto ao tempo da restauração, tanto em esmalte quanto em dentina, o grupo 2 apresentou os menores valores; o padrão de fratura predominante para todos os grupos foi a Adesiva; houveram alterações morfológicas notáveis em esmalte e dentina após a dose acumulativa de 30Gy, onde aos 60Gy, no esmalte, os prismas se tornaram amorfos e a camada interprismática degradada, e na dentina os túbulos dentinários encontravam-se completamente obliterados; na análise da interface adesiva do grupo 2 notou-se que quase não houve formação de tags e nos grupos 3 de esmalte a camada adesiva formada era mais fina, porém com formação de tags mais prolongados e na dentina houve formação de gaps. / Head and neck cancer is among all kinds of cancer the seventh most common and radiotherapy (RT) is one of its main treatments, which is widely used and efficient, but side effects are unavoidable. A dental treatment before RT is very important to reduce/eliminate infectious foci in the oral cavity, so it is essential to eliminate carious lesions, and after RT \"radiation caries\", which are a side effect of the treatment, must be eliminated. Adhesive systems are the most indicated to restore teeth of patients undergoing RT, so this study aimed to evaluate in vitro the effect of RT in the moment of the dental restorations in enamel and dentin, using shear bond strength tests, evaluate morphologic alterations at teeth surface during RT, with a laser confocal microscopy and to evaluate qualitatively the union interface of the composite/ dental substrate by scanning electron microscope (SEM). It was used 60 third molars, which were sectioned into 120 fragments of enamel and 120 of dentin, and after the surface prepare the specimens were randomly divided into 4 groups (n=30): G1 (control) - no irradiated substrate + restorative procedure; G2 - restorative procedure performed before RT; G3 - restorative procedure performed after RT; e G4 - restorative procedure performed 6 months after RT. Each group was divided into 2 subgroups: Subgroup \"A\" (SGA) in which was used the AdperTM Single Bond 2 (SB); and subgrup \"B\" in which was used Clearfil SE Bond (CL), for the restorative procedure. The specimens were fractionally irradiated by a dose of 2Gy/day, 5 consecutive days, until it reached a total dose of 60Gy, in a total of 30 fractions, lasting 6 weeks. For the restorative treatment the resin Z350 was chosen, and for standardization it was used a matrix so all specimens had 4mm height and 2mm in diameter. The specimens were submitted to shear bond strength test and the fracture pattern was evaluated. It was chosen 5 specimens of each substrate for the morfological evaluation of the dental surface by a laser confocal microscopy, those were evaluate every 10Gy. To evaluate the adhesive interface it was chosen 3 specimens of each group and those were prepared for the SEM. A better performance was observed for the CL, in both dental substrates, rather than the SB; according to the period of restoration, in both enamel and dentin, Group 2 has showed lower values; the predominant fracture pattern to all groups was the Adesive one; there were morphological alterations in enamel and dentin after a cumulative dose of 30Gy, the prisms of enamel became formless and the interprismatic region was degraded after 60Gy, at the dentin the dental tubules were completely amorphous; the analysis of the interface adhesion has showed that in group 2 tags were barely formed, and in group 3 of enamel the adhesive layer was thinner, but tags were longer, and at the dentin gaps were observed.
217

Propriedades física e adesiva do esmalte dental após radioterapia e colagem de bráquetes ortodônticos / Physical and adhesive properties of dental enamel after radiotherapy and bonding orthodontic brackets

Gabriela Cristina Santin 01 December 2014 (has links)
O objetivo deste trabalho foi avaliar as propriedades físicas e adesivas do esmalte dental após radioterapia e colagem de bráquetes ortodônticos metálicos e cerâmicos. O estudo foi dividido em duas etapas. Na primeira, foram utilizados 10 molares permanentes humanos hígidos, que foram seccionados em fragmentos de esmalte de 1 mm² e divididos entre grupo irradiado e não irradiado, de forma pareada. O grupo irradiado foi submetido à radiação ionizante, com uma dose total de 60 Gy, 2 Gy/dia, durante seis semanas, com intervalo de dois dias entre às semana. Os fragmentos de esmalte dental foram submetidos a teste mecânicos de microcisalhamento para verificar se a radioterapia alterou a resistência coesiva do esmalte dental irradiado. A segunda etapa deste estudo utilizou-se de 90 pré-molares humanos hígidos e devidamente preparados, divididos em seis grupos/subgrupos (n=15): G1 - dentes não irradiados e não envelhecidos; G2 - dentes não irradiados e envelhecidos; G3 - dentes irradiados e envelhecidos; Subgrupos: bráquetes metálicos (M) e bráquetes cerâmicos (C). Os grupos G2 e G3 foram submetidos à envelhecimento artificial acelerado por meio de termociclagem, simulando o período aproximado de 1 a 2 anos, tempo esse indicado para o início de tratamento ortodôntico em pacientes pós radioterapia. Em seguida, os grupos G2 e G3 foram submetidos à radioterapia, conforme descrito. Finalizado o ciclo radioterápico, os bráquetes foram colados no esmalte dental dos espécimes com compósito Transbond XT, sendo o bráquete metálico Morelli e cerâmico Radiance. Após 24 horas, os corpos de prova foram submetidos à teste mecânico de cisalhamento e a superfície do esmalte avaliada em microscopia confocal de varredura à laser (MCVL) avaliando o índice de remanescente adesivo (IRA) e modo de fratura. Em seguida, quatro corpos de prova que apresentaram fratura do tipo coesiva de cada grupo/subgrupos foram devidamente preparados e a interface compósito/esmalte avaliada em MCVL e microscopia eletrônica de varredura. Os fragmentos de esmalte dental submetidos à radiação apresentaram menores valores de resistência ao cisalhamento do que o esmalte dental não irradiado (p<0,05). Levando em consideração a interação dos fatores dos espécimes submetidos ao teste de cisalhamento, os grupo/subgrupos submetidos à radiação e colados bráquetes cerâmicos, apresentaram menores valores de resistência. Os grupos não submetidos à irradiação, G1-M e G2-M, apresentaram com maior frequência IRA escore 0 (sem compósito na superfície), enquanto, os grupos G1-C, G2-C, G3-M e G3-C apresentaram mais de 50% de compósito aderido à superfície Quanto ao modo de fratura, os grupos controle apresentaram em sua maioria os tipos de fratura adesiva (Ad) e coesiva resina (CR), independente do tipo de bráquete Os bráquetes metálicos colados em esmalte dental submetidos à irradiação apresentaram fratura do tipo mista coesiva resina/adesiva (CR/Ad), enquanto os bráquetes cerâmicos resultaram em fraturas coesiva resina (CR) e coesiva resina/adesiva (CR/Ad). Nas imagens obtidas da região de interface compósito/esmalte, observou-se que os tags de resina foram mais extensos no esmalte dental irradiado, circundando os prismas de esmalte. Assim, conclui-se que a radiação diminuiu a resistência coesiva do esmalte dental e que os espécimes submetidos à radioterapia apresentaram maior falha adesiva entre bráquete/compósito e tags de resina mais extensos e profundos quando comparados ao grupo controle / The objective of this study was to evaluate the physical and adhesive properties of the enamel after radiotherapy and bonding of metal and ceramic orthodontic brackets. The study was divided into two stages. In the first one, 10 human permanent molars, which were cut into fragments of enamel 1 mm² and divided between irradiated and non-irradiated group, in a paired form. The irradiated group was subjected to ionizing radiation, with a total dose of 60 Gy, 2 Gy / day for six weeks, with an interval of two days between the weeks. The enamel fragments were subjected to mechanical testing to verify that microshear radiotherapy changed cohesive strength of the irradiated enamel. In The second phase of this study, was used 90 healthy and properly prepared human premolars,divided into six groups / subgroups (n = 15): G1 - non-irradiated teeth and not aged; G2 teeth unirradiated and aged; G3 - irradiated and aged teeth; Subgroups: metallic brackets (M) and ceramic brackets (C). G2 and G3 were subjected to accelerated artificial aging by thermal cycling, simulating period of approximately 1 to 2 years, this time indicated for the beginning of orthodontic treatment in post radiotherapy patients. Then the G2 and G3 groups underwent radiotherapy as described. After the radiotherapy cycle, the brackets were bonded on the enamel specimens with Transbond XT, and the metallic and Morelli ceramic bracket Radiance. After 24 hours, the specimens were subjected to mechanical shear test and evaluated the enamel surface in confocal laser scanning microscopy (CLSM) evaluating the adhesive remnant index (ARI) and fracture mode. Then four specimens showed that the cohesive fracture type were properly prepared for each group / subgroup and the composite interface / enamel evaluated CLSM and scanning electron microscopy. Fragments enamel subjected to radiation had significantly lower shear strength than the non-irradiated enamel (p <0.05). Considering the interaction of the factors of the specimens subjected to shear stress, the group / subgroup undergoing radiation and bonded ceramic brackets showed lower resistance values. The two groups were subjected to irradiation, G1 and G2-M-M, showed more IRA frequency scores of 0 (no composite surface), while the C-G1, G2, C, G3 and G3-M-C groups had more 50% of adhesive left on the surface Concerning the fracture mode, the control groups showed mostly the types of adhesive fracture (Ad) and cohesive resin (CR), regardless of the bracket\'s metal brackets bonded submitted to enamel irradiation, that showed mixed type of cohesive resin / adhesive (CR / Ad) fracture, while ceramic brackets resulted in cohesive fractures resin (CR) and cohesive resin / adhesive (CR / Ad). In images obtained from the composite region / enamel interface, it was observed that the resin tags were more extensive in the irradiated tooth enamel surrounding the enamel prisms. Thus, it is concluded that radiation decreased the tensile strength of the enamel and the specimens treated with radiotherapy had higher adhesive failure between bracket / composite and tags of more extensive and deep resin, compared to the control group
218

Resistência ao cisalhamento de selante associado a dois sistemas adesivos, após contaminação salivar: influência da fotopolimerização individual e simultânea / Shear bond strength of a pit-and-fissure sealant associated with two adhesive systems after salivary contamination: influence of individual and simultaneous light curing

Jaciara Miranda Gomes da Silva 06 August 2007 (has links)
Este trabalho teve por objetivo avaliar \"in vitro\" a resistência ao cisalhamento de um selante resinoso (Fluroshield - F) em associação com um sistema adesivo total-etch (Adper Single Bond 2-SB) e um self-etching (Clearfil S3 Bond-S3) em condições de contaminação salivar, comparando dois protocolos de fotopolimerização: individual do sistema adesivo e, em seguida, do selante ou simultânea de ambos materiais conjuntamente. Superfícies mesiais e distais de 45 terceiros molares humanos hígidos foram incluídas e planificadas, o sítio de adesão delimitado (Ø 3mm) e os corpos-de-prova alocados aleatoriamente em 6 grupos experimentais (n=15), de acordo com o tratamento empregado: I- F aplicado sobre o esmalte condicionado com ácido fosfórico a 37% (controle). Os demais grupos foram contaminados com saliva (0,01ml por 10 s) e a seguir foram aplicados: II- SB e F fotopolimerizados separadamente; III- SB e F fotopolimerizados conjuntamente; IVS3 e F fotopolimerizados separadamente; V- S3 e F fotopolimerizados simultaneamente; VI- F aplicado sem associação com adesivos sobre o esmalte condicionado e contaminado. A seguir, um cilindro de selante foi confeccionado com o auxílio de uma mesa metálica e de matriz de teflon bipartida sobre o sítio de adesão. Após armazenamento durante 24 horas a 37°C em água destilada, os espécimes foram submetidos ao teste de resistência ao cisalhamento em Máquina de Ensaios Universal (0,5mm/min; 50Kgf). As interfaces adesivas foram analisadas quanto ao tipo de fratura em microscópio óptico com 20x de aumento e para análise qualitativa, três espécimes de cada grupo, foram selecionados e analisados em microscópio eletrônico de varredura. As médias obtidas, em MPa, e os desvios padrão foram: I-12,28 (±4,29); II-8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V- 11,45 (±3,77); e VI-7,47 (±1,99). A análise estatística, por meio da Análise de Variância e teste de Fisher, demonstrou que a contaminação salivar afetou negativamente a resistência adesiva. A associação do sistema adesivo self-etching ao selante resultou em uma média semelhante estatisticamente ao grupo controle. Comparando os protocolos de fotopolimerização, não houve diferença estatisticamente significante entre os grupos nos quais foi realizada a fotopolimerização simultânea ou individual dos materiais. Com base nestes resultados pôde-se concluir que o protocolo de fotopolimerização não afetou os valores de resistência adesiva ao esmalte condicionado e contaminado. A associação do sistema adesivo self-etching Clearfil S3 Bond ao selante Fluroshield aumentou a resistência ao cisalhamento com diferença estastísticamente significante em relação aos grupos nos quais foi utilizado o sistema adesivo Adper Single Bond 2 e com valor médio semelhante ao grupo controle, no qual o selante foi aplicado em condições ideais, na ausência de contaminação salivar. / The purpose of this study was to evaluate in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with a total-etch (Adper Single Bond 2 - SB) and a self-etching adhesive system (Clearfil S3 Bond - S3) under conditions of salivary contamination, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal surfaces from 45 sound third molars were embedded, flattened and a 3-mm-diameter bonding site was demarcated. The specimens were randomly assigned to 6 experimental groups (n=15), according to the bonding technique: I - F was applied to the enamel etched with 37% phosphoric acid. The other groups were contaminated with saliva (0.01 mL during 10 s). II - SB and F were light cured separately; III - SB and F were light cured together; IV - 3S and F were light cured separately; V - 3S and F were light cured simultaneously; VI - F was applied to salivary-contaminated etched enamel without an intermediate bonding agent layer. Thereafter, a sealant cylinder was fabricated using a metallic clamping device and a split Teflon matrix placed over the bonding site. After 24-hour storage in distilled water at 37°C, shear bond strength was measured using a knifeedge blade in a universal testing machine (0.5 mm/mm; 50 kgf). The debonded interfaces were examined with an optical microscope to determine the failure modes. For a qualitative analysis, 3 specimens from each group were selected and observed under scanning electron microscopy. Means (±SD) in MPa were: I-12,28 (±4,29); II 8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V-11,45 (±3,77); and VI-7,47 (±1,99). Statistical analysis by ANOVA and Fisher\'s test showed that salivary contamination affected negatively the bond strength. The association between the self-etching adhesive system and sealant yielded bond strength mean statistically similar to that of the control group. Comparing the curing protocols, there was no statistically significant difference between the groups with simultaneous or individual light curing of the materials. Based on these results, it may be concluded that the curing protocol did not affect the bond strength to the contaminated etched enamel. The association of Clearfil S3 Bond self-etching adhesive system to Fluroshield sealant increased the shear bond strength with statistically significant difference from the groups with Adper Single Bond 2 adhesive system, and showing mean value similar to that of the control group, in which the sealant was applied under ideal conditions, without salivary contamination.
219

Avaliação da Resistência ao Cisalhamento de Resíduos Sólidos Urbanos com Codisposição de Lodo de Tratamento de Esgoto através de Ensaios de Cisalhamento Direto de Grandes Dimensões

de Queiroz Motta, Eduarda 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:38:43Z (GMT). No. of bitstreams: 2 arquivo6632_1.pdf: 6764865 bytes, checksum: 22507d03f369d858a9f0f728efb1c48b (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta tese apresenta uma avaliação da resistência ao cisalhamento de resíduos sólidos urbanos com codisposição de lodo de tratamento de esgoto. Neste sentido, verifica-se através de ensaios de cisalhamento direto de grandes dimensões sua influência nos parâmetros de resistência, e por outro lado, verifica-se através de reatores em escala de laboratório a alteração dos processos biodegradativos dos resíduos sólidos na geração de gases (concentração, pressão e vazão). Avalia-se também, a influência de materiais fibrosos presentes nos resíduos (plásticos, têxteis, dentre outros) como elemento de reforço na resistência ao cisalhamento. Para o desenvolvimento desta pesquisa, foi construído um equipamento de cisalhamento direto de grandes dimensões onde foram realizados ensaios com amostras com três diferentes composições, utilizando-se resíduos sólidos pré-tratados mecanicamente, sendo: 1) amostra total; 2) resíduos com redução dos materiais fibrosos; 3) resíduos com adição de lodo. Finalmente, foi realizada uma análise de estabilidade de taludes de RSU, utilizando-se a geometria usual de projetos de aterros sanitários, onde foram considerados: sua composição com e sem codisposição de lodo; o efeito das fibras como componente de reforço; e a influência de poro-pressão de lixiviados e do biogás. Os resultados da pesquisa mostram a importância dos componentes fibrosos na resistência ao cisalhamento dos resíduos sólidos, conferindo altos valores aos parâmetros de resistência devido à tensão de tração das fibras. Verificou-se também que é possível se atingir poro-pressões de biogás e lixiviado muito altas, dentro de uma situação de estabilidade
220

Efeito de diferentes modelos de envelhecimento na resistência de união em dentina decídua hígida e cariada / Different degradations models to evaluate bond strength in sound and caries primary dentin

Ana Flávia Bissoto Calvo 04 March 2015 (has links)
A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00). O modelo in situ influenciou negativamente os valores de RU nos grupos RC e CIVMR (p<0,001) no substrato hígido e na RC (p<0,001), CIVMR (p=0,001) e CIVAV p=0,020) no substrato cariado. Concluí-se que no modelo in vitro, seis meses em água destilada não foram suficientes para degradar a interface de união dos materiais avaliados e o modelo in situ é uma metodologia rápida que pode ser utilizada para avaliar a degradação da interface de união de materiais restauradores em dentina cariada de dentes decíduo. / Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days. Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00). The in situ model, adversely, influenced the BS in RC and RMGIC groups (p <0.001) in sound substrate, and in RC (p <0.001), RMGIC (p = 0.001) and HVGIC (p = 0.020) in caries-affected dentin. We can concluded that in in vitro model, using six months distilled water, was not sufficient to degrade the bonded interface of the evaluated materials and in situ model is a faster method to evaluate degradation of the adhesion interface of restorative materials in cariesaffected dentin.

Page generated in 0.0907 seconds