• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • Tagged with
  • 15
  • 15
  • 15
  • 15
  • 8
  • 8
  • 8
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resistência de vias aéreas inferiores de indivíduos obesos medida através da oscilometria de impulso

Gonçalves de Albuquerque, Cláudio 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T16:23:21Z (GMT). No. of bitstreams: 2 arquivo2891_1.pdf: 2072524 bytes, checksum: 8ab122b9c42267080ed267bbae1c259c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O sistema de oscilometria de impulso (IOS) é uma técnica de avaliação da mecânica do sistema respiratório que necessita de cooperação mínima dos pacientes, bastando que estes respirem normalmente, em volume corrente, em um bocal. Os principais dados obtidos são a medida da resistência total de vias aéreas (R5Hz), da resistência de vias aéreas centrais (R20Hz), da freqüência de ressonância (Fres), que estima a resistência de vias aéreas periféricas e também pode ser obtida pela diferença R5Hz-R20Hz, e da reatância do sistema respiratório (X5Hz), que mede os componentes elásticos pulmonares. Uma característica peculiar do IOS é a possibilidade de avaliar a distensibilidade das vias aéreas nos diversos volumes pulmonares, e, assim, indiretamente, o grau de remodelamento destas vias aéreas. Na revisão narrativa, abordamos inicialmente alguns aspectos dos princípios biofísicos e da aplicabilidade clínica dos dados obtidos através do IOS, bem como procuramos estabelecer sua relação com os outros métodos de avaliação da mecânica pulmonar. Neste tipo de revisão, os trabalhos mais relevantes, na opinião dos autores, são selecionados a partir de pesquisa bibliográfica empregando descritores selecionados. No artigo original foram estudados indivíduos com vários níveis de índice de massa corpórea (IMC) nos quais a medida da resistência de vias aéreas (Rva) foi realizada empregando o IOS. Verificamos que há uma maior Rva periféricas em indivíduos com IMC ≥ 40kg/m2 comparados aos indivíduos não obesos. Houve uma moderada correlação entre o IMC e a Rva periférica (medidas através da R5Hz-R20Hz e da Fres), a correlação entre o IMC e o fluxo expiratório a 25 e 75% da capacidade vital forçada (FEF25-75%) obtido pela espirometria foi fraca. Também observamos que a oscilometria de impulso foi capaz de identificar alterações da mecânica pulmonar em pacientes que apresentaram teste espirométrico normal. As propriedades do IOS tornam o teste útil na análise e identificação de anormalidades das vias aéreas que não podem ser observadas por outras técnicas de avaliação. É necessário que mais pesquisas sejam realizadas para estabelecer critérios e graduações bem definidas desta técnica, visto o grande potencial de sua utilização e facilidade da realização do exame
2

Estudo da resistividade das vias aéreas em camundongos obesos

TEIXEIRA, Vanessa Pereira 07 February 2014 (has links)
A obesidade está aumentando de forma epidêmica em todo o mundo e a mesma possui efeito profundo na fisiologia da respiração, estando associada com estado de crônica inflamação sistêmica, que pode promover a hiper-reatividade das vias aéreas. Para estudar os processos que ocorrem nas vias aéreas, o presente estudo teve como objetivo avaliar a resistividade das vias aéreas de camundongos da linhagem Swiss induzidos à obesidade. Como metodologia foi realizada a análise dos efeitos da indução da obesidade pelo modelo de redução de ninhada; mecânica respiratória para analisar a resistividade do sistema respiratório pela mensuração das variáveis: elastância tecidual (Htis), das resistências dos pulmões (Gtis) e das vias aéreas (Raw) e histeresividade (η); análise morfométrica do tecido pulmonar para quantificar as células inflamatórias e os alvéolos normais, colapsados e hiperinsuflados; quantificação das proteínas colágeno III e elastina dos animais da ninhada normal e reduzida por meio da técnica do Western Blot, para verificar a presença de remodelamento. De acordo com os resultados obtidos foi possível constatar a eficácia do modelo de indução, pois houve aumento do peso corporal, do índice de Lee e da massa de gordura periepididimal e retroperitoneal. Com relação à mecânica pulmonar, não houve diferença entre os grupos para os valores basais, após a administração de salina (Sal) e metacolina (MCh), nos parâmetros Raw, Gtis, Htis e η. Frente ao desafio com salbutamol (Salb), apenas o η, que representa relação entre dissipação e conservação de energia nos tecidos pulmonares, apresentou diferença entre os grupos, sendo maior no grupo ninhada reduzida. Esse resultado pode ser atribuído a heterogeneidade acarretada pela broncoprovocação e a diminuição da resposta a broncodilatadores promovida pela inflamação e pela alteração da matriz extracelular. Houve diminuição de alvéolos normais e aumento do colapso alveolar, que pode acarretar aumento da viscoelasticidade pulmonar e heterogeneidade apresentada pelo mesmo o que também pode ser atribuído à presença do aumento de colágeno III e diminuição da elastina, encontrados neste estudo. Essa alteração do conteúdo de fibras colágenas e elásticas sugere um processo de remodelamento. Houve aumento de células inflamatórias mononucleares e polimorfonucleares o que indica presença de processo inflamatório, que também pode auxiliar no processo de remodelamento e desencadear hiper-responsividade. Portanto, a obesidade acarretou aumento de células inflamatórias, alterações na matriz extracelular do parênquima pulmonar e colapso alveolar nos animais da ninhada reduzida, porém não houve modificação nos parâmetros Raw, Gtis, Htis da mecânica pulmonar entre os grupos e no parâmetro η houve diferença após a administração do salbutamol, demonstrando que não houve alteração da responsividade. / Obesity is increasing in epidemic form throughout the world and it has a profound effect on the physiology of respiration and is associated with a state of chronic systemic inflammation, which can promote the hyperreactivity of the airways. To study the processes that occur in the airways, this study aimed to evaluate the resistivity of the airways strain obesity induced Swiss mice. We analyzed the effects of induction of obesity by reducing litter model; respiratory mechanics, to analyze the resistivity of the respiratory system by: tissue elastance (Htis), the resistances of the lungs (Gtis) and airway (Raw) and histeresividade (η), morphometric analysis of lung tissue for quantification of inflammatory cells and normal, collapsed and hyperinflated alveoli; quantification of the proteins collagen type III and elastin in animals normal and litter reduced by the technique of Western Blot to verify the presence of remodeling. According to the obtained results it can be seen that the induction model was effective because there was an increase in body weight, Lee index and mass periepididymal and retroperitoneal fat. With respect to lung mechanics, there was no difference between groups for baseline values after administration of saline (Sal) and methacholine (MCh) in Raw, Gtis, Htis and η parameters. Upon salbutamol (Salb) challenge, only the η, which represents a relationship between dissipation and energy conservation in the lung tissues, differed between groups, being higher in reduced litter group. This result can be attributed to heterogeneity entailed by bronchial provocation and diminished response to bronchodilators promoted by inflammation and alterations of the extracellular matrix. There was a decrease in normal alveoli and alveolar collapse increases, which can lead to an increased heterogeneity of lung and viscoelasticity for the same which can be attributed to the presence of increased and decreased collagen III, elastin, found in this study. This change of the content of collagen and elastic fibers suggests a remodeling process. There was an increase of mononuclear and polymorphonuclear inflammatory cells indicating the presence of inflammation, which can also aid in the remodeling process and lead to hyper- responsiveness. Therefore, obesity caused increase in inflammatory cells, changes in the extracellular matrix of the lung parenchyma and alveolar collapse in animals reduced litter, but there was no change in Raw, Gtis, Htis parameters of pulmonary mechanics between groups and the parameter η was no difference after administration of salbutamol, demonstrating that there had no change in responsiveness. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
3

Resistência das vias aéreas : técnica do interruptor versus pletismografia : uma nova abordagem

Gritti, Leandro Antonio January 2010 (has links)
Fundamentação: A resistência das vias aéreas (Rva) é a diferença de pressão entre o alvéolo e a boca dividida pela taxa de fluxo. Este parâmetro pode ser obtido pela pletismografia, técnica mais complexa e disponível em poucos centros. O método do interruptor (Rint) é simples, de fácil execução, exigindo pouca colaboração, portátil, baixo custo relativo à pletismografia. Em crianças há valores de referência e correlação com a técnica pletismográfica. Em adultos existem poucos dados de correlação. Objetivo: Avaliar a concordância da Rva pelo método do Rint com o método pletismográfico. Método: As medidas de Rint foram feitas na expiração, em posição sentada, com clipe nasal e suporte das bochechas. O exame pletismográfico foi realizado da maneira habitual. Realizamos medidas de comparação entre os métodos antes e após a administração inalatória de broncodilatador. Resultados: Analisamos um total de 87 pacientes de 18 a 82 anos de idade, sendo 52,5% mulheres. Houve concordância entre os métodos (r=0,8 e ICC=0,8) para pacientes com VEF1% ≥ 60. O Rint também teve boa concordância com a pletismografia no diagnóstico de aumento da resistência das vias aéreas, notadamente para medidas de Rint ≥4 cm/H2O/L/s (RV >8 e índice Kappa 0,73). Conclusão: O presente estudo identificou que a concordância entre o Rint e a pletismografia é boa em indivíduos menos graves (VEF1%≥60). A concordância no diagnóstico de aumento ou normalidade da Rva entre os dois métodos foi forte. O Rint é um método potencialmente útil na prática assistencial em adultos.
4

Resistência das vias aéreas : técnica do interruptor versus pletismografia : uma nova abordagem

Gritti, Leandro Antonio January 2010 (has links)
Fundamentação: A resistência das vias aéreas (Rva) é a diferença de pressão entre o alvéolo e a boca dividida pela taxa de fluxo. Este parâmetro pode ser obtido pela pletismografia, técnica mais complexa e disponível em poucos centros. O método do interruptor (Rint) é simples, de fácil execução, exigindo pouca colaboração, portátil, baixo custo relativo à pletismografia. Em crianças há valores de referência e correlação com a técnica pletismográfica. Em adultos existem poucos dados de correlação. Objetivo: Avaliar a concordância da Rva pelo método do Rint com o método pletismográfico. Método: As medidas de Rint foram feitas na expiração, em posição sentada, com clipe nasal e suporte das bochechas. O exame pletismográfico foi realizado da maneira habitual. Realizamos medidas de comparação entre os métodos antes e após a administração inalatória de broncodilatador. Resultados: Analisamos um total de 87 pacientes de 18 a 82 anos de idade, sendo 52,5% mulheres. Houve concordância entre os métodos (r=0,8 e ICC=0,8) para pacientes com VEF1% ≥ 60. O Rint também teve boa concordância com a pletismografia no diagnóstico de aumento da resistência das vias aéreas, notadamente para medidas de Rint ≥4 cm/H2O/L/s (RV >8 e índice Kappa 0,73). Conclusão: O presente estudo identificou que a concordância entre o Rint e a pletismografia é boa em indivíduos menos graves (VEF1%≥60). A concordância no diagnóstico de aumento ou normalidade da Rva entre os dois métodos foi forte. O Rint é um método potencialmente útil na prática assistencial em adultos.
5

Resistência das vias aéreas : técnica do interruptor versus pletismografia : uma nova abordagem

Gritti, Leandro Antonio January 2010 (has links)
Fundamentação: A resistência das vias aéreas (Rva) é a diferença de pressão entre o alvéolo e a boca dividida pela taxa de fluxo. Este parâmetro pode ser obtido pela pletismografia, técnica mais complexa e disponível em poucos centros. O método do interruptor (Rint) é simples, de fácil execução, exigindo pouca colaboração, portátil, baixo custo relativo à pletismografia. Em crianças há valores de referência e correlação com a técnica pletismográfica. Em adultos existem poucos dados de correlação. Objetivo: Avaliar a concordância da Rva pelo método do Rint com o método pletismográfico. Método: As medidas de Rint foram feitas na expiração, em posição sentada, com clipe nasal e suporte das bochechas. O exame pletismográfico foi realizado da maneira habitual. Realizamos medidas de comparação entre os métodos antes e após a administração inalatória de broncodilatador. Resultados: Analisamos um total de 87 pacientes de 18 a 82 anos de idade, sendo 52,5% mulheres. Houve concordância entre os métodos (r=0,8 e ICC=0,8) para pacientes com VEF1% ≥ 60. O Rint também teve boa concordância com a pletismografia no diagnóstico de aumento da resistência das vias aéreas, notadamente para medidas de Rint ≥4 cm/H2O/L/s (RV >8 e índice Kappa 0,73). Conclusão: O presente estudo identificou que a concordância entre o Rint e a pletismografia é boa em indivíduos menos graves (VEF1%≥60). A concordância no diagnóstico de aumento ou normalidade da Rva entre os dois métodos foi forte. O Rint é um método potencialmente útil na prática assistencial em adultos.
6

Avaliação experimental da responsividade das vias aéreas em camundongos após indução do enfisema pulmonar por elastase

CERVILHA, Daniela Aparecida de Brito 10 January 2014 (has links)
A Doenca Pulmonar Obstrutiva Cronica (DPOC) e uma patologia que apresenta obstrucao ao fluxo aereo. No enfisema ocorre destruicao da matriz extracelular que resulta no alargamento do espaco aereo. A hiper-responsividade bronquica pode ocorrer em pacientes com DPOC. Nesse contexto o objetivo desse estudo foi averiguar a responsividade bronquica apos desafio com metacolina (MCh) em um modelo de enfisema induzido por elastase pancreatica de porco (PPE). Para tal utilizamos camundongos machos Swiss (25-30g), divididos aleatoriamente em tres grupos: o grupo controle foi instilado via intratraqueal com solucao salina e o grupo enfisema subdividido em dois grupos instilados com PPE (0,3 e 0,6U). Apos 20 dias, os animais foram anestesiados, traqueostomizados, acoplados em ventilador para pequenos animais e submetidos a inalacao de salina e MCh (50 e 100mg/mL). A avaliacao da mecanica respiratoria utilizou o modelo de fase constante e os parametros analisados foram resistencia das vias aereas (Raw), resistencia tecidual (G), elastancia tecidual (H) e histeresividade (ƒÅ). Apos o teste, os pulmoes foram removidos para analises histologicas e quantificacao de proteinas. Os resultados da mecanica respiratoria mostraram que os valores de Raw, G e ƒÅ, tanto basais quanto apos nebulizacao com salina, nao apresentaram diferencas entre os grupos quando comparado com o grupo controle, porem a H no grupo enfisema 0,6U foi menor quando comparado com o grupo controle. Apos o desafio com MCh 100mg/mL, a Raw foi atenuada nos animais com enfisema 0,3U. A G aumentou nos animais com enfisema 0,3U. A H nos animais com enfisema 0,6U diminuiu. A ƒÅ apos nebulizacao de MCh 50 e 100mg/ml elevou-se nos animais instilados com PPE 0,3 e 0,6U. Na analise morfologica, o grupo tratado com PPE 0,6U aumentou as areas de colapso alveolar, o numero de alveolos hiperinsuflados foi maior nos grupos enfisema 0,3 e 0,6U, o intercepto linear medio elevou-se em ambos os grupos tratados com PPE e o numero de alveolos normais reduziu em ambos os grupos enfisema quando comparado com o grupo controle. A quantificacao de proteinas mostrou diminuicao de elastina no grupo 0,6U e aumento de colageno tipo III nos grupos 0,3 e 0,6U. Os resultados mostraram que animais com enfisema induzido por PPE 0,3U apresentam atenuacao da responsividade bronquica durante a inalacao de MCh (100mg/mL), sugerindo que a perda da integridade do epitelio pulmonar e o remodelamento tecidual aumentam a heterogeneidade dos pulmoes. / Chronic Obstructive Pulmonary Disease (COPD) is a disease that presents airflow obstruction. In emphysema, there is destruction of the extracellular matrix resulting in enlargement of the airspace. The bronchial hyperresponsiveness can occur in patients with COPD. In this context, the objective of this study was to evaluate the responsiveness after bronchial challenge with methacholine (MCh) in a model of emphysema induced by porcine pancreatic elastase (PPE). Swiss male mice (25 - 30g) were randomly divided into three groups: the control group was intratracheally instilled with saline and emphysema group was subdivided into two other groups that were instilled with PPE (0.3 and 0.6 U). After 20 days the animals were anesthetized , tracheotomized , connected to ventilator for small animals and subjected to inhalation of salina and MCh (50 and 100mg/mL) . The evaluation of respiratory mechanics used the model of constant phase and the parameters analyzed were airway resistance (Raw), tissue resistance (G), tissue elastance (H) and hysteresivity (ç). The lungs were removed for histological analysis and quantification of proteins after the test. The results of respiratory mechanics showed that the baseline and after nebulization with saline the parameters Raw, G and ç showed no differences between groups when compared with the control group, but the H in group emphysema 0.6U was lower . After challenge with MCh 100mg/mL Raw was attenuated in animals with emphysema 0.3U. The G increased in animals with emphysema 0.3U. The H in animals with emphysema 0.6 U decreased. The ç after misting of MCh 50 and 100mg/mL increased in animals instilled with PPE 0.3 and 0.6U. In the morphological analysis the group treated with PPE 0.6U increased areas of alveolar collapse, alveolar number of hyperinflation was higher in groups emphysema 0.3 and 0.6U, linear mean intercept increased in both groups treated with PPE and reduced number of normal alveoli in both groups emphysema when compared with the control group. The protein quantification showed decrease of elastin in the group 0.6 U and increased collagen type III in the groups treated with PPE. Our results show that animals with elastase-induced emphysema 0.3U have attenuation of bronchial hyperresponsiveness during inhalation of MCh (100mg/mL), suggesting that loss of integrity of the epithelial lung tissue and tissue remodeling increased the heterogeneity of lungs. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
7

Desenvolvimento de um sistema FOT (Técnica de Oscilações Forçadas) e sua aplicação na avaliação da mecânica respiratória / Development of a FOT system (Forced Oscillation Technique) and its application in evaluation of respiratory mechanics

Cruz, Andrea Fonseca da 01 December 2016 (has links)
INTRODUÇÃO: A avaliação da mecânica respiratória descreve as propriedades mecânicas do sistema respiratório (SR) através da determinação de índices úteis para avaliar a função pulmonar. Nos pacientes em ventilação mecânica, os métodos mais utilizados são o estático, por meio de pausas em que a resistência inspiratória (RINS) e a elastância estática (EST) são calculadas, e o dinâmico, onde a aplicação da equação do movimento (EM) dos gases estima a resistência (REM) e a elastância (EEM) do SR. Já nos indivíduos atentos e respirando espontaneamente, a espirometria e a pletismografia são as técnicas mais empregadas e a EM também é uma opção. A técnica de oscilação forçada (FOT) possibilita a medição da impedância mecânica do SR e seus componentes resistivos (RFOT), elásticos (EFOT) e inerciais, que têm sido utilizados na avaliação da mecânica respiratória. OBJETIVOS: Desenvolver um sistema FOT e avaliar sua aplicabilidade na monitorização da mecânica respiratória nos pacientes em ventilação mecânica e nos indivíduos em ventilação espontânea. MÉTODOS: Um sistema FOT composto de oscilador, módulo de sinais e softwares de aquisição e processamento foi desenvolvido e validado utilizando modelos mecânicos. Em suínos sob ventilação mecânica, o sistema FOT foi utilizado durante a titulação decrescente da pressão positiva ao final da expiração (PEEP) e a RFOT e EFOT em cada PEEP foi comparada com a REM e EEM. Em pacientes intubados e sob ventilação mecânica, o sistema FOT foi utilizado na PEEP, na pressão média e na pressão de platô do ciclo ventilatório. Nos pacientes a RFOT e EFOT, foram comparadas com a REM e EEM e também com a RINS e a EEST. Nos voluntários, a FOT foi superimposta à respiração espontânea e a RFOT e EFOT foi comparada com a REM e EEM obtidas por meio da pressão transpulmonar. RESULTADOS: A validação do sistema FOT nos modelos mecânicos foi bem-sucedida e resultou em valores próximos dos esperados. Nos seis suínos analisados, as diferenças encontradas entre a FOT e a EM tiveram origem principalmente na variabilidade de cenários e nos valores dos parâmetros fluxo, volume e pressão empregados em cada método. Nos quatro pacientes, as características dos métodos e a variabilidade dos parâmetros ventilatórios explicaram a maior parte das diferenças observadas. Nos quatro voluntários, assim como na literatura, os dados da FOT apresentaram valores maiores que os dados EM, porém, as causas ainda não foram totalmente esclarecidas. CONCLUSÕES: O sistema FOT foi desenvolvido conforme os requisitos de segurança, portabilidade e usabilidade. A impedância mecânica e seus componentes podem ser utilizados na avaliação da mecânica respiratória, mas sua comparação direta com outros métodos não é possível devido as diferenças intrínsecas dos métodos e principalmente pelos distintos valores de fluxo, volume e pressão encontrados em cada um dos métodos / INTRODUCTION: The evaluation of respiratory mechanics describes the mechanical properties of the respiratory system (SR) through the determination of useful indexes to assess lung function. In mechanically ventilated patients, the most commonly used methods are: 1) static, through end-inspiratory and end-expiratory hold maneuvers, the resistance (RINS) and static elastance (EEST) are calculated; 2) dynamic, where the application of the equation of motion (EM) estimates the resistance (REM) and the elastance (EEM) of the SR. In spontaneously breathing individuals, spirometry and plethysmography are the most used techniques and EM is also an option. The forced oscillation technique (FOT) enables the measurement of the mechanical impedance of the SR and its resistive (RFOT), elastic (EFOT) and inertial components that have been used to assess respiratory mechanics. OBJECTIVES: Develop a FOT system and to evaluate its effectiveness in monitoring respiratory mechanics in mechanically ventilated patients and individuals in spontaneous ventilation. METHODS: A FOT system comprising the oscillator, the signal module and software for acquisition and processing were developed and validated using mechanical models. In pigs under mechanical ventilation, the FOT system was used during the positive end-expiratory pressure (PEEP) titration and RFOT and EFOT in each PEEP was compared with REM and EEM. In intubated and mechanically ventilated patients, the FOT system was used at the PEEP, mean pressure and plateau pressure of the ventilatory cycle. In patients, RFOT and EFOT were compared with REM and EEM and also with the RINS and EEST. In volunteers, the FOT was superimposed to the spontaneous breathing and RFOT and EFOT were compared with REM and EEM obtained with the transpulmonary pressure. RESULTS: The validation of the FOT system in the mechanical models was successful and resulted in values close to those expected. In the six pigs tested, the differences between the FOT and EM were due to the variability in the scenarios and in the values of the parameters flow, volume and pressure used in each method. In four patients evaluated, the characteristics of the methods and the variability of ventilatory parameters explained most of the differences observed. In our four volunteers, as well as in literature, the FOT data showed higher values that EM data, however, the causes have not yet been fully clarified. CONCLUSIONS: The FOT system was developed according to the safety, usability and portability requirements. The mechanical impedance and its components can be used to evaluate the respiratory mechanics, but its direct comparison to other methods is not possible due to intrinsic differences between methods and mainly by different values of flow, volume and pressure found in each method
8

Desenvolvimento de um sistema FOT (Técnica de Oscilações Forçadas) e sua aplicação na avaliação da mecânica respiratória / Development of a FOT system (Forced Oscillation Technique) and its application in evaluation of respiratory mechanics

Andrea Fonseca da Cruz 01 December 2016 (has links)
INTRODUÇÃO: A avaliação da mecânica respiratória descreve as propriedades mecânicas do sistema respiratório (SR) através da determinação de índices úteis para avaliar a função pulmonar. Nos pacientes em ventilação mecânica, os métodos mais utilizados são o estático, por meio de pausas em que a resistência inspiratória (RINS) e a elastância estática (EST) são calculadas, e o dinâmico, onde a aplicação da equação do movimento (EM) dos gases estima a resistência (REM) e a elastância (EEM) do SR. Já nos indivíduos atentos e respirando espontaneamente, a espirometria e a pletismografia são as técnicas mais empregadas e a EM também é uma opção. A técnica de oscilação forçada (FOT) possibilita a medição da impedância mecânica do SR e seus componentes resistivos (RFOT), elásticos (EFOT) e inerciais, que têm sido utilizados na avaliação da mecânica respiratória. OBJETIVOS: Desenvolver um sistema FOT e avaliar sua aplicabilidade na monitorização da mecânica respiratória nos pacientes em ventilação mecânica e nos indivíduos em ventilação espontânea. MÉTODOS: Um sistema FOT composto de oscilador, módulo de sinais e softwares de aquisição e processamento foi desenvolvido e validado utilizando modelos mecânicos. Em suínos sob ventilação mecânica, o sistema FOT foi utilizado durante a titulação decrescente da pressão positiva ao final da expiração (PEEP) e a RFOT e EFOT em cada PEEP foi comparada com a REM e EEM. Em pacientes intubados e sob ventilação mecânica, o sistema FOT foi utilizado na PEEP, na pressão média e na pressão de platô do ciclo ventilatório. Nos pacientes a RFOT e EFOT, foram comparadas com a REM e EEM e também com a RINS e a EEST. Nos voluntários, a FOT foi superimposta à respiração espontânea e a RFOT e EFOT foi comparada com a REM e EEM obtidas por meio da pressão transpulmonar. RESULTADOS: A validação do sistema FOT nos modelos mecânicos foi bem-sucedida e resultou em valores próximos dos esperados. Nos seis suínos analisados, as diferenças encontradas entre a FOT e a EM tiveram origem principalmente na variabilidade de cenários e nos valores dos parâmetros fluxo, volume e pressão empregados em cada método. Nos quatro pacientes, as características dos métodos e a variabilidade dos parâmetros ventilatórios explicaram a maior parte das diferenças observadas. Nos quatro voluntários, assim como na literatura, os dados da FOT apresentaram valores maiores que os dados EM, porém, as causas ainda não foram totalmente esclarecidas. CONCLUSÕES: O sistema FOT foi desenvolvido conforme os requisitos de segurança, portabilidade e usabilidade. A impedância mecânica e seus componentes podem ser utilizados na avaliação da mecânica respiratória, mas sua comparação direta com outros métodos não é possível devido as diferenças intrínsecas dos métodos e principalmente pelos distintos valores de fluxo, volume e pressão encontrados em cada um dos métodos / INTRODUCTION: The evaluation of respiratory mechanics describes the mechanical properties of the respiratory system (SR) through the determination of useful indexes to assess lung function. In mechanically ventilated patients, the most commonly used methods are: 1) static, through end-inspiratory and end-expiratory hold maneuvers, the resistance (RINS) and static elastance (EEST) are calculated; 2) dynamic, where the application of the equation of motion (EM) estimates the resistance (REM) and the elastance (EEM) of the SR. In spontaneously breathing individuals, spirometry and plethysmography are the most used techniques and EM is also an option. The forced oscillation technique (FOT) enables the measurement of the mechanical impedance of the SR and its resistive (RFOT), elastic (EFOT) and inertial components that have been used to assess respiratory mechanics. OBJECTIVES: Develop a FOT system and to evaluate its effectiveness in monitoring respiratory mechanics in mechanically ventilated patients and individuals in spontaneous ventilation. METHODS: A FOT system comprising the oscillator, the signal module and software for acquisition and processing were developed and validated using mechanical models. In pigs under mechanical ventilation, the FOT system was used during the positive end-expiratory pressure (PEEP) titration and RFOT and EFOT in each PEEP was compared with REM and EEM. In intubated and mechanically ventilated patients, the FOT system was used at the PEEP, mean pressure and plateau pressure of the ventilatory cycle. In patients, RFOT and EFOT were compared with REM and EEM and also with the RINS and EEST. In volunteers, the FOT was superimposed to the spontaneous breathing and RFOT and EFOT were compared with REM and EEM obtained with the transpulmonary pressure. RESULTS: The validation of the FOT system in the mechanical models was successful and resulted in values close to those expected. In the six pigs tested, the differences between the FOT and EM were due to the variability in the scenarios and in the values of the parameters flow, volume and pressure used in each method. In four patients evaluated, the characteristics of the methods and the variability of ventilatory parameters explained most of the differences observed. In our four volunteers, as well as in literature, the FOT data showed higher values that EM data, however, the causes have not yet been fully clarified. CONCLUSIONS: The FOT system was developed according to the safety, usability and portability requirements. The mechanical impedance and its components can be used to evaluate the respiratory mechanics, but its direct comparison to other methods is not possible due to intrinsic differences between methods and mainly by different values of flow, volume and pressure found in each method
9

Alterações do espaço aéreo faríngeo em pacientes hiperdivergentes submetidos a osteotomias maxilomandibulares com diferentes amplitudes de rotação anti-horária do plano oclusal /

Borsato, Karina Tostes. January 2020 (has links)
Orientador: Jonas Bianchi / Resumo: A rotação anti-horária do plano oclusal (RAHPO), quando associada à cirurgia de avanço maxilomandibular (AMM), tem demonstrado resultados eficazes com melhoras volumétricas do espaço aéreo. Em média são reportadas RAHPO de 4 a 6 º, sendo que poucos estudos avaliaram os efeitos do AMM associado a amplas RAHPO (≥8) no espaço aéreo. Além disso, esse procedimento aumenta a carga mecânica na articulação temporomandibular (ATM), podendo ocasionar processos degenerativos condilares. Deste modo, é necessário avaliar se os possíveis riscos à saúde das ATMs, são justificados em razão de uma melhora adicional das dimensões do espaço aéreo. Portanto, o objetivo desse estudo foi avaliar se as mudanças promovidas pelo AMM e amplas RAHPO promove aumentos adicionais significativos do espaço aéreo faríngeo quando comparadas com moderadas RAHPO (<8º). Para isso, foi realizado um estudo retrospectivo longitudinal, utilizando TCFC de 62 indivíduos submetidos a cirurgia de AMM e diferentes RAHPO em dois tempos distintos: T1-pré cirúrgico e T2-pós cirúrgico. A amostra foi dividida em 2 grupos: Grupo 1 – 32 pacientes submetidos a AMM com ampla RAHPO (média -10.75, DP 2.59) e Grupo 2 – 30 pacientes submetidos a AMM com moderadas RAHPO (média -3.86, DP 2.67). As alterações morfológicas das vias aéreas superiores total, retropalatal e retroglossal foram analisadas no Software Dolphin Imaging® a partir das medidas de volume, área, mínima área axial e medidas lineares lateral e anteroposterior. Como res... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
10

Morfologia craniofacial e da via aérea em indivíduos com Espectro Oculoauriculovertebral /

Parizotto, Julianna de Oliveira Lima. January 2020 (has links)
Orientador: João Roberto Gonçalves / Resumo: O espectro oculoauriculovertebral (EOAV), também conhecido como Síndrome de Goldenhar, afeta o desenvolvimento de estruturas dos 1º e 2º arcos branquiais que envolvem alterações mandibulares, oculares, vertebrais, auriculares e estruturas extracranianas. A maioria dos estudos sobre o EOAV são relatos clínicos e aqueles com populações significativas são descrições fenotípicas. Os estudos que avaliaram a morfologia tiveram seus resultados limitados ao incluir indivíduos com envolvimento unilateral, bilateral, leve, moderado e grave, na mesma amostra. Dessa forma, os objetivos do presente estudo foram de caracterizar a morfologia craniofacial e da via aérea e suas possíveis correlações em uma amostra homogênea (n = 18) composta apenas por indivíduos com EOAV unilateral grave. A análise da via aérea foi realizada por meio do Software Dolphin Imaging®. Para avaliar a morfologia craniofacial, sete medidas morfométricas foram realizadas com Software Materialize Mimics®. Para comparar as variáveis das vias aéreas e morfométricas, foi utilizado um grupo controle pareado por idade e sexo. Pelo teste de Shapiro-Wilk, observou-se que 13 das 35 variáveis não apresentaram distribuição normal. O teste t de Student foi aplicado para as variáveis de distribuição normal e Mann-Whitney para aquelas sem distribuição normal. Comparando os grupos Controle e OAVS para medidas craniofaciais, 16 das 26 variáveis foram estatisticamente significantes e, para as medidas das vias aéreas, todas foram esta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Oculoauriculovertebral spectrum (OAVS), also known as Goldenhar Syndrome, affects the development of structures of the 1st and 2nd branchial arches that involve mandibular, ocular, vertebral, auricular changes, as well as extracranial structures. Most OAVS studies are clinical reports, and those with significant populations are phenotypic description. Studies that evaluated morphology had their results limited by including individuals with unilateral, bilateral, mild, moderate and severe involvement in the same sample. The objectives of this study were to characterize the craniofacial and airway morphology and its possible correlations in a homogeneous sample (n = 18) composed only of unilateral severe OAVS individuals. Airway analysis was performed using Dolphin Imaging® software. To evaluate craniofacial morphology, seven morphometric measurements were performed by Materialize Mimics® Software. To compare airway and morphometric variables, a control group matched by age and sex was used. Through the Shapiro-Wilk test, it was observed that 13 of the 35 variables did not have normal distribution. Student's t-test was applied for the normal distribution variables and Mann-Whitney for those without normal distribution. Comparing the Control and OAVS groups for craniofacial measurements, 16 of the 26 variables were statistically significant, and for airway measurements all were statistically significant except for the RG Area variable. Pearson and Spearman's correlation coef... (Complete abstract click electronic access below) / Mestre

Page generated in 0.117 seconds