Spelling suggestions: "subject:"ressonância dde plasmon dde superfície"" "subject:"ressonância dde plasmon dee superfície""
1 |
Modificação eletroquímica da superfície de filmes finos de ouro SERS e SPR ativosJarske, André Oliveira Silva January 2011 (has links)
Thin metal films have attracted much interest because they provide a way to produce surface plasmon resonance (SPR) in the Kretschmann configuration. This technique is a very sensitive for determining small changes at the interface between a metallic layer and
a dielectric medium, and the metals generally used are silver and gold once their surface plasmon resonances are located in the visible range. Thin films of gold, due their stability and diversity applications, have been extensively studied by electrochemistry, surface enhanced Raman spectroscopy (SERS) and techniques of Microscopic such as AFM and
STM. The Raman technique has been used to the analysis of organics compounds in determined system. However, in very low concentration levels is inefficient due to weak signal or interference from noise. A developed method to markedly increase the signal of a species presented at many levels is the SERS. One of the major considerations for the formation of a SERS-active surface is surface roughness, and this has been realized by various ways. In the present work, we analyzed the efects of various oxidation-reduction cycles (ORCs) on the surface of the thin films of gold using the techniques of cyclic voltammetry, microscopy, UV-Vis spectroscopy and SPR, which will be used to evaluate
the efficiency of electrochemically modified substrates as SERS and SPR active. Initially,
the film was cycling in a solution of H2SO4 to remove impurities from the surface. After
this procedure, the 50 nm and 100 nm thick gold films, deposited on a glass substrate,
were subjected to a series of ORCs in a solution of H2SO4 containing 0,005 M KCl
electrolyte. As the number of ORCs is increased, the roughness of the film increased. We used techniques of microscopy, Spectroscopy UV-Vis, Resonance Plasmon Surface and Cyclic Voltammetry to characterize the surface of the film as a function of roughness. A “home − made” SPR system based on the configuration of Kretschmann was utilized for analyzed the changes provoked in surface film before and after the electrochemically
modified. The medium size of the gold islands deposited was analyzed for Atomic Force
Microscopy (AFM) and Scanning Tunneling Microscopy (STM). This same metallic film,
after passing for oxidation processes and reduction, was used to obtain a spectrum SER
using an organic molecule the 2-thiouracil adsorbed on the surface of the film. The results observed for AFM, STM and cyclic voltammetry shows that surfaces electrochemically modified increase the roughness, and that the changes modified o depth of the signal SPR. These change provoked electrochemistry after various ORC improve significantly the Raman sign of molecules adsorbed on the surfaces of the metallic films. Finally, we conducted an evaluation of the roughness factor obtained through the techniques of AFM, STM and cyclic voltammetry. _______________________________________________________________________________________ RESUMO: Filmes finos metalicos tem despertado muito interesse devido a possibildade de produzir Ressonancia de Plasmons de Superfıcie (SPR) utilizando uma configuracao de Kretschmann. Esta tecnica e muito sensıvel na determinacao de pequenas mudancas na interface entre uma camada metalica e um meio dieletrico, e os metais usados geralmente
sao prata e ouro, uma vez que a ressonancia de plasmon da superfıcie desses metais
esta localizada na regiao do visıvel. Esses filmes, devido a sua estabilidade e diversidade de aplicacoes, tem sido extensivamente estudados por tecnicas eletroquımicas, espectroscopia Raman intenficada por superfıcie (SERS) e por tecnicas de microscopia tais como o AFM e STM. A Espectroscopia Raman tem sido utilizada para a analise de compostos
organicos em determinados sistemas. No entanto, em sistemas que possuem concentracoes muito baixas, o sinal Raman e extremamente fraco e ineficiente, ou sofre interferencias de ruıdos. Um dos metodos desenvolvidos para aumentar significativamente o sinal de uma especie adsorvida sobre uma superfıcie metalica em varios nıveis e o SERS. Uma das consideracoes importantes para a formacao de um substrato SERS ativo e a rugosidade da superfıcie, e a obtencao dessas superfıcies tem sido realizado de diversas maneiras. No presente trabalho, analisamos o efeito de diferentes ciclos de oxidacao-reducao (ORCs) sobre a superfıcie de filmes finos de ouro, utilizando as tecnicas de voltametria cıclica, microscopias, espectroscopia UV-Vis e SPR, que serao utilizadas para avaliar a eficiencia dos substratos modificados eletroquimicamente como SERS e SPR ativos. Inicialmente, o filme e ciclado em uma solucao de H2SO4 para remover as impurezas da superfıcie. Apos este procedimento, os filmes com espessuras de 50 e 100 nm, depositados sobre um substrato de vidro, foram submetidos a uma serie de ORCs em uma solucao de H2SO4.
|
2 |
Desenvolvimento de metodologia para funcionalizar superfícies de ouro com biomoléculas. Construção de biosensor para detecção de citocromo c. / Development of methodology to functionalize gold surfaces with biomolecules. Construction of biosensor for detection of cytochrome cTrolise, Rodrigo Matias 16 December 2010 (has links)
Neste trabalho estão apresentadas novas estratégias para funcionalizar superfícies de ouro baseadas na sustentação de bicamadas lipídicas em superfícies de sensores de imagem por Ressonância de Plasmons de Superfície (SPRi) e a construção de um biosensor para detecção de citocromo c. SPRi é uma técnica ótica de gravimetria em tempo real. Por meio de medidas de variações de índice de refração (n) próximas a uma interface, a adsorção e desorção de moléculas podem ser mensuradas. Inicialmente testamos várias estratégias para encontrar um suporte adequado que se ligasse na superfície de ouro e que oferecesse sustentação e estabilidade para a bicamada de fosfolipídeo biotinilado. Estudos de FT-IR e MEV mostraram que a quitosana facilita a formação de uma bicamada íntegra de fosfolipídeos, de tal modo, que a mesma alcança valores de espessura próximos àqueles previstos, ~ 34,5 Å. Além disso, mostramos que esse sistema apresenta vantagens perante outros modelos, tais como, (poli-lisina/fosfolipídeos) e (tiol hidrofóbico/fosfolipídeo). Utilizando-se o complexo químico biotina/estreptoavidina conseguimos imobilizar o anticorpo anti cit c na bicamada, mantendo-o afastado da superfície de ouro. A construção do biosensor foi acompanhada com experimentos de SPRi. O limite de detecção de citocromo c atingido foi de 10-11mol/L. Um sensor construído somente com BSA e anticorpo anti cit c apresentou sensibilidade semelhante. Esta sensibilidade é em torno de três ordens de grandeza superior aos experimentos de imunoblotting usualmente utilizados para detecção de cit c. A principal limitação deste biosensor, tal como de outros imunoensaios, está intimamente ligada às vantagens e desvantagens dos anticorpos como ferramentas analíticas. / In this work we developed new strategies to functionalize gold surfaces based on the support of lipid bilayers on the surfaces of surface plasmon resonance imaging sensors (SPRi) and the construction of a biosensor for detection of cytochrome c. SPRi is an optical gravimetric real time technique. Through measurements of changes in refractive index (n) in close proximity to an interface, the adsorption and desorption of molecules can be measured. Initially we tested several strategies for finding a suitable medium that would adsorb on the gold surface and also support and stabilize a biotinylated phospholipid bilayer. Studies of FT-IR and SEM showed that chitosan induces the formation of an intact phospholipid bilayer, so that it reaches thickness values close to those expected, ~ 34.5 Å. Furthermore, we showed that this system has advantages in relation to other models, such as (poli-lisine/phospholipids) and (thiol hydrophobic / phospholipid). Using the chemical complex biotin/streptavidin anti cyt c antibody could be immobilized in the bilayer, keeping it away from the gold surface. The construction of the biosensor was accompanied with SPRi experiments. The limit of detection of cytochrome c was achieved from 10-11mol / L. A sensor built only with BSA and anti cyt c showed similar sensitivity. This sensitivity is about three orders of magnitude higher than the immunoblotting experiments commonly used for detection of cyt c. The main limitation of this biosensor, like in other immunoassays, is linked to the advantages and disadvantages of antibodies as analytical tools.
|
3 |
Desenvolvimento de metodologia para funcionalizar superfícies de ouro com biomoléculas. Construção de biosensor para detecção de citocromo c. / Development of methodology to functionalize gold surfaces with biomolecules. Construction of biosensor for detection of cytochrome cRodrigo Matias Trolise 16 December 2010 (has links)
Neste trabalho estão apresentadas novas estratégias para funcionalizar superfícies de ouro baseadas na sustentação de bicamadas lipídicas em superfícies de sensores de imagem por Ressonância de Plasmons de Superfície (SPRi) e a construção de um biosensor para detecção de citocromo c. SPRi é uma técnica ótica de gravimetria em tempo real. Por meio de medidas de variações de índice de refração (n) próximas a uma interface, a adsorção e desorção de moléculas podem ser mensuradas. Inicialmente testamos várias estratégias para encontrar um suporte adequado que se ligasse na superfície de ouro e que oferecesse sustentação e estabilidade para a bicamada de fosfolipídeo biotinilado. Estudos de FT-IR e MEV mostraram que a quitosana facilita a formação de uma bicamada íntegra de fosfolipídeos, de tal modo, que a mesma alcança valores de espessura próximos àqueles previstos, ~ 34,5 Å. Além disso, mostramos que esse sistema apresenta vantagens perante outros modelos, tais como, (poli-lisina/fosfolipídeos) e (tiol hidrofóbico/fosfolipídeo). Utilizando-se o complexo químico biotina/estreptoavidina conseguimos imobilizar o anticorpo anti cit c na bicamada, mantendo-o afastado da superfície de ouro. A construção do biosensor foi acompanhada com experimentos de SPRi. O limite de detecção de citocromo c atingido foi de 10-11mol/L. Um sensor construído somente com BSA e anticorpo anti cit c apresentou sensibilidade semelhante. Esta sensibilidade é em torno de três ordens de grandeza superior aos experimentos de imunoblotting usualmente utilizados para detecção de cit c. A principal limitação deste biosensor, tal como de outros imunoensaios, está intimamente ligada às vantagens e desvantagens dos anticorpos como ferramentas analíticas. / In this work we developed new strategies to functionalize gold surfaces based on the support of lipid bilayers on the surfaces of surface plasmon resonance imaging sensors (SPRi) and the construction of a biosensor for detection of cytochrome c. SPRi is an optical gravimetric real time technique. Through measurements of changes in refractive index (n) in close proximity to an interface, the adsorption and desorption of molecules can be measured. Initially we tested several strategies for finding a suitable medium that would adsorb on the gold surface and also support and stabilize a biotinylated phospholipid bilayer. Studies of FT-IR and SEM showed that chitosan induces the formation of an intact phospholipid bilayer, so that it reaches thickness values close to those expected, ~ 34.5 Å. Furthermore, we showed that this system has advantages in relation to other models, such as (poli-lisine/phospholipids) and (thiol hydrophobic / phospholipid). Using the chemical complex biotin/streptavidin anti cyt c antibody could be immobilized in the bilayer, keeping it away from the gold surface. The construction of the biosensor was accompanied with SPRi experiments. The limit of detection of cytochrome c was achieved from 10-11mol / L. A sensor built only with BSA and anti cyt c showed similar sensitivity. This sensitivity is about three orders of magnitude higher than the immunoblotting experiments commonly used for detection of cyt c. The main limitation of this biosensor, like in other immunoassays, is linked to the advantages and disadvantages of antibodies as analytical tools.
|
4 |
Caracterização por ressonância de plasmons de superfície de biossensores eletroquímicos aplicados à detecção de neurotoxinas. / Characterization by surface plasmon resonance of electrochemical biosensors applied to neurotoxins detection.Souza, Diego Custódio de 13 November 2013 (has links)
Os dispositivos biossensores foram primeiramente pesquisados por Clark e Lyons, em 1962, visando medir o nível de glicemia. Atualmente, há uma popularização dos medidores de glicemia e diversas tecnologias foram desenvolvidas, principalmente, para aplicações em diagnósticos médicos e monitoramento ambiental. No entanto, há uma ampla quantidade de aplicações para biossensores ainda não disponível no mercado. A imobilização de espécies bioativas que interagem diretamente com o analito, chamada de superfície bioativa, é frequentemente considerada a etapa mais difícil no desenvolvimento de biossensores para novas aplicações. O objetivo deste trabalho é demonstrar a caracterização da camada bioativa desenvolvida pela técnica de construção de camadas auto-organizadas usando o princípio da adsorção eletrostática. Para isto, foram utilizadas três diferentes concentrações de soluções compostas por ligações covalentes entre nanotubos de carbono de paredes múltiplas e três diferentes biomateriais, Polietilenoimina, Ácido Desoxirribonucléico e enzimas do tipo Hidrolase de Organofosforados. As diferentes soluções polieletrolíticas foram caracterizadas pela técnica de ressonância de plasmons de superfície e simultaneamente formaram camadas auto-organizadas na superfície de um eletrodo de carbono vítreo. A atividade das enzimas foi analisada por voltametria cíclica para as diferentes concentrações das soluções utilizadas. Os resultados mostraram que a caracterização por ressonância de plasmons de superfície promove o controle da adsorção eletrostática. A variação do ângulo de ressonância de plasmons de superfície corresponde à intensidade e à saturação das interações eletrostáticas entre as camadas. Biossensores desenvolvidos com soluções de maior concentração, consequentemente, ampliaram os limites de detecção e elevaram a resolução do sinal elétrico. Em aplicações para medir baixas concentrações do analito, o adequado controle das concentrações das soluções poli eletrolíticas reduz os custos no desenvolvimento de biossensores especialmente, com relação ao custo de enzimas isoladas. / The biosensor devices were first researched by Clark and Lyons in 1962, aiming to measure the blood glucose level. Currently, there is a popularization of blood glucose meters and several technologies have been developed mainly for applications in medical diagnostics and environmental monitoring. However, there is a wide range of applications for biosensors not yet available. The immobilization of bioactive species that interact directly with the analyte, called bioactive surface, is often considered the most difficult step in the biosensors development for new applications. The objective of this work is to demonstrate the characterization of the bioactive surface developed by self-assembled monolayers technique using the electrostatic adsorption principle. For this, we used three different concentrations of solutions composed of covalent bonds between multi-walled carbon nanotubes and three different biomaterials, Polyethyleneimine, Deoxyribonucleic Acid and Organophosphorous Hydrolase enzymes. These enzymes catalyze the hydrolysis of phosphorus compounds such as organophosphorous neurotoxins. The different polyelectrolyte solutions were characterized by the technique of surface plasmon resonance, and simultaneously, self-assembled monolayers were formed on the surface of a glassy carbon electrode. The enzymes activity was analyzed by cyclic voltammetry for the different concentrations of the solutions used. The results showed that the surface plasmon resonance characterization promote the control of electrostatic adsorption. The variation of the surface plasmon resonance angle corresponds the intensity and saturation of electrostatic interactions between the layers. Biosensors developed with solutions of higher concentration, consequently, widened the detection limits, and increased the resolution of the electrical signal. In applications to measure low concentrations of analyte, adequate control of the concentrations of polyelectrolytes solutions reduces costs in the development of biosensors especially, the cost of isolated enzymes.
|
5 |
Caracterização por ressonância de plasmons de superfície de biossensores eletroquímicos aplicados à detecção de neurotoxinas. / Characterization by surface plasmon resonance of electrochemical biosensors applied to neurotoxins detection.Diego Custódio de Souza 13 November 2013 (has links)
Os dispositivos biossensores foram primeiramente pesquisados por Clark e Lyons, em 1962, visando medir o nível de glicemia. Atualmente, há uma popularização dos medidores de glicemia e diversas tecnologias foram desenvolvidas, principalmente, para aplicações em diagnósticos médicos e monitoramento ambiental. No entanto, há uma ampla quantidade de aplicações para biossensores ainda não disponível no mercado. A imobilização de espécies bioativas que interagem diretamente com o analito, chamada de superfície bioativa, é frequentemente considerada a etapa mais difícil no desenvolvimento de biossensores para novas aplicações. O objetivo deste trabalho é demonstrar a caracterização da camada bioativa desenvolvida pela técnica de construção de camadas auto-organizadas usando o princípio da adsorção eletrostática. Para isto, foram utilizadas três diferentes concentrações de soluções compostas por ligações covalentes entre nanotubos de carbono de paredes múltiplas e três diferentes biomateriais, Polietilenoimina, Ácido Desoxirribonucléico e enzimas do tipo Hidrolase de Organofosforados. As diferentes soluções polieletrolíticas foram caracterizadas pela técnica de ressonância de plasmons de superfície e simultaneamente formaram camadas auto-organizadas na superfície de um eletrodo de carbono vítreo. A atividade das enzimas foi analisada por voltametria cíclica para as diferentes concentrações das soluções utilizadas. Os resultados mostraram que a caracterização por ressonância de plasmons de superfície promove o controle da adsorção eletrostática. A variação do ângulo de ressonância de plasmons de superfície corresponde à intensidade e à saturação das interações eletrostáticas entre as camadas. Biossensores desenvolvidos com soluções de maior concentração, consequentemente, ampliaram os limites de detecção e elevaram a resolução do sinal elétrico. Em aplicações para medir baixas concentrações do analito, o adequado controle das concentrações das soluções poli eletrolíticas reduz os custos no desenvolvimento de biossensores especialmente, com relação ao custo de enzimas isoladas. / The biosensor devices were first researched by Clark and Lyons in 1962, aiming to measure the blood glucose level. Currently, there is a popularization of blood glucose meters and several technologies have been developed mainly for applications in medical diagnostics and environmental monitoring. However, there is a wide range of applications for biosensors not yet available. The immobilization of bioactive species that interact directly with the analyte, called bioactive surface, is often considered the most difficult step in the biosensors development for new applications. The objective of this work is to demonstrate the characterization of the bioactive surface developed by self-assembled monolayers technique using the electrostatic adsorption principle. For this, we used three different concentrations of solutions composed of covalent bonds between multi-walled carbon nanotubes and three different biomaterials, Polyethyleneimine, Deoxyribonucleic Acid and Organophosphorous Hydrolase enzymes. These enzymes catalyze the hydrolysis of phosphorus compounds such as organophosphorous neurotoxins. The different polyelectrolyte solutions were characterized by the technique of surface plasmon resonance, and simultaneously, self-assembled monolayers were formed on the surface of a glassy carbon electrode. The enzymes activity was analyzed by cyclic voltammetry for the different concentrations of the solutions used. The results showed that the surface plasmon resonance characterization promote the control of electrostatic adsorption. The variation of the surface plasmon resonance angle corresponds the intensity and saturation of electrostatic interactions between the layers. Biosensors developed with solutions of higher concentration, consequently, widened the detection limits, and increased the resolution of the electrical signal. In applications to measure low concentrations of analyte, adequate control of the concentrations of polyelectrolytes solutions reduces costs in the development of biosensors especially, the cost of isolated enzymes.
|
6 |
Aplicativo web para projeto de sensores ópticos baseados em ressonância de plasmons de superífice em interfaces planaresCAVALCANTI, Leonardo Machado 16 August 2016 (has links)
Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2017-01-30T18:17:26Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
DISSERTACAO_LEO_DEFESA - FINAL - CATALOGADA PDF.pdf: 4585329 bytes, checksum: 4b70c80127866cd2da97a6217bb6a34f (MD5) / Made available in DSpace on 2017-01-30T18:17:27Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
DISSERTACAO_LEO_DEFESA - FINAL - CATALOGADA PDF.pdf: 4585329 bytes, checksum: 4b70c80127866cd2da97a6217bb6a34f (MD5)
Previous issue date: 2016-08-16 / CNPQ / Um dos principais desafios no projeto de sensores baseados em Ressonância de Plasmons de Superfície — RPS — é maximizar sua sensibilidade. Neste trabalho é proposto o uso de dois algoritmos heurísticos, Monte Carlo e Enxame de Partículas, para otimização de sensores baseados em RPS em interfaces planares, i.e, nas configurações de Kretschmann e de Otto, sem o auxílio da aproximação lorentziana para a curva de ressonância. Devido à natureza probabilística dos algoritmos, consegue-se obter um método simples e robusto para atingir essa otimização. É feita uma comparação quanto à eficiência computacional dos algoritmos em relação ao método tradicional de otimização, ficando demonstrado que o método de Enxame de Partículas é o mais eficiente em relação às outras técnicas. Com o emprego desse método, a dependência espectral dos parâmetros ótimos é obtida para sensores utilizando vários metais nas configurações de Kretschmann e de Otto, tanto para aplicações em meios gasosos quanto em meios aquosos. Um aplicativo foi desenvolvido e sua funcionalidade demonstrada, que pode ser executado diretamente via web, com base na metodologia proposta, para otimização de sensores RPS em interfaces planares. / One of the main challenges in the design of surface plasmon resonance – SPR – sensor systems is to maximize their sensitivity. In this work one proposes the use of two heuristic algorithms, Monte Carlo and Particle Swarm, for optimization of SPR sensors in planar interfaces, i.e, in the Kretschmann and Otto configurations, without use of the Lorentzian approximation to the resonance curve. Because of the probabilistic nature of the algorithms, one manages to obtain a simple and robust method to achieve optimization. A comparison is made on the computational efficiency of the algorithm relative to the traditional method of optimization, showing that the particle swarm optimization method is more efficient compared to other techniques. By employing this method, the spectral dependence of optimum parameters is obtained for sensors using a wide range of metal films in the Kretschmann and Otto configurations, both for applications in gaseous an in aqueous media. An app was developed and its functionality can be demonstrated, by direct execution via web, based on the proposed methodology for optimization of SPR sensors on planar interfaces.
|
7 |
Implantação iônica de baixa energia em polímero para desenvolvimento de camadas compósitas nanoestruturadas condutoras litografáveis. / Low energy ion implantation into polymers to develop conductive composite layers for lithography.Teixeira, Fernanda de Sá 28 June 2010 (has links)
Eletrônica utilizando polímero em substituição ao silício é uma área de pesquisa recente com perspectivas econômicas promissoras. Compósitos de polímeros com partículas metálicas apresentam interessantes propriedades elétricas, magnéticas e ópticas e têm sido produzidos por uma grande variedade de técnicas. Implantação iônica de metais utilizando plasma é um dos métodos utilizados para obtenção desses compósitos condutores. Neste trabalho é realizada implantação de íons de ouro de baixa energia em PMMA utilizando plasma. O PMMA tem grande importância tecnológica sendo largamente utilizado como resiste em litografias por feixe de elétrons, raios-X, íons e deep-UV. Como resultado da implantação iônica de baixa energia em PMMA há formação de uma camada nanométrica de material condutor. Esse novo material, denominado compósito isolante-condutor, permite criar micro e nanodispositivos através de técnicas largamente utilizadas em microeletrônica. Medidas elétricas são realizadas in situ em função da dose de íons metálicos implantada, o que permite um estudo das propriedades de transporte desses novos materiais, que podem ser modeladas pela teoria da percolação. Simulações utilizando o programa TRIDYN permitem obter a profundidade e o perfil da implantação dos íons. São mostradas caracterizações importantes tais como Microscopia Eletrônica de Transmissão, Microscopia de Varredura por Tunelamento, Espalhamento de Raios-X a Baixos Ângulos, Difração de Raios-X e Espectroscopia UV-vis. Essas técnicas permitem visualizar e investigar o caráter nanoestruturado do compósito metal-polímero. Ainda como parte deste projeto, as camadas condutoras formadas no polímero são caracterizadas quanto à manutenção das suas características de elétron resiste. / Electronics using polymers instead of silicon is a recent research area with promising economic perspectives. Polymer with metallic particles composites presents interesting electrical, magnetic and optical properties and they have been produced by a broad variety of techniques. Metal ion implantation using plasma is one of the used methods to obtain conductor composites. In this work it is performed low energy gold ion implantation in PMMA by using plasma. PMMA has great technological importance once it is broadly used as resist in electron-beam, X-ray, ion and deep UV lithography. As a result of low energy ion implantation in PMMA, a nanometric conducting layer is formed. This new material, named insulator-conductor composite, can allow the creation of micro and nanodevices through well known microelectronics techniques. Electrical measurements are performed in situ as a function of metal ions implanted dose, which allows the investigation of electrical transport of these new materials, which can be modeled by the percolation theory. Simulations using TRIDYN computer code provide the prediction of depth profile of implanted ions. Important characterizations are showed such as Transmission Electron Microscopy, Scanning Tunneling Microscopy, Small Angle X-Ray Scattering, X-Ray Diffraction and UV-vis Spectroscopy. These techniques allow to visualize and to investigate the nanostructured character of the metal-polymer composite. Still as a part of this project, the conducting layers formed are characterized in relation to the maintenance of their characteristics as electron-beam resist.
|
8 |
Implantação iônica de baixa energia em polímero para desenvolvimento de camadas compósitas nanoestruturadas condutoras litografáveis. / Low energy ion implantation into polymers to develop conductive composite layers for lithography.Fernanda de Sá Teixeira 28 June 2010 (has links)
Eletrônica utilizando polímero em substituição ao silício é uma área de pesquisa recente com perspectivas econômicas promissoras. Compósitos de polímeros com partículas metálicas apresentam interessantes propriedades elétricas, magnéticas e ópticas e têm sido produzidos por uma grande variedade de técnicas. Implantação iônica de metais utilizando plasma é um dos métodos utilizados para obtenção desses compósitos condutores. Neste trabalho é realizada implantação de íons de ouro de baixa energia em PMMA utilizando plasma. O PMMA tem grande importância tecnológica sendo largamente utilizado como resiste em litografias por feixe de elétrons, raios-X, íons e deep-UV. Como resultado da implantação iônica de baixa energia em PMMA há formação de uma camada nanométrica de material condutor. Esse novo material, denominado compósito isolante-condutor, permite criar micro e nanodispositivos através de técnicas largamente utilizadas em microeletrônica. Medidas elétricas são realizadas in situ em função da dose de íons metálicos implantada, o que permite um estudo das propriedades de transporte desses novos materiais, que podem ser modeladas pela teoria da percolação. Simulações utilizando o programa TRIDYN permitem obter a profundidade e o perfil da implantação dos íons. São mostradas caracterizações importantes tais como Microscopia Eletrônica de Transmissão, Microscopia de Varredura por Tunelamento, Espalhamento de Raios-X a Baixos Ângulos, Difração de Raios-X e Espectroscopia UV-vis. Essas técnicas permitem visualizar e investigar o caráter nanoestruturado do compósito metal-polímero. Ainda como parte deste projeto, as camadas condutoras formadas no polímero são caracterizadas quanto à manutenção das suas características de elétron resiste. / Electronics using polymers instead of silicon is a recent research area with promising economic perspectives. Polymer with metallic particles composites presents interesting electrical, magnetic and optical properties and they have been produced by a broad variety of techniques. Metal ion implantation using plasma is one of the used methods to obtain conductor composites. In this work it is performed low energy gold ion implantation in PMMA by using plasma. PMMA has great technological importance once it is broadly used as resist in electron-beam, X-ray, ion and deep UV lithography. As a result of low energy ion implantation in PMMA, a nanometric conducting layer is formed. This new material, named insulator-conductor composite, can allow the creation of micro and nanodevices through well known microelectronics techniques. Electrical measurements are performed in situ as a function of metal ions implanted dose, which allows the investigation of electrical transport of these new materials, which can be modeled by the percolation theory. Simulations using TRIDYN computer code provide the prediction of depth profile of implanted ions. Important characterizations are showed such as Transmission Electron Microscopy, Scanning Tunneling Microscopy, Small Angle X-Ray Scattering, X-Ray Diffraction and UV-vis Spectroscopy. These techniques allow to visualize and to investigate the nanostructured character of the metal-polymer composite. Still as a part of this project, the conducting layers formed are characterized in relation to the maintenance of their characteristics as electron-beam resist.
|
Page generated in 0.1292 seconds