Spelling suggestions: "subject:"rugosidade"" "subject:"rugosidades""
111 |
Avalia??o tribol?gica de um ?leo mineral aditivado com nanopart?culas superparamagn?ticas de ?xido de ferroSantos, Marcionila Neli Lima dos 14 August 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2018-01-15T21:40:48Z
No. of bitstreams: 1
MarcionilaNeliLimaDosSantos_DISSERT.pdf: 11845216 bytes, checksum: ab27f3a37cb03e804ce73ec2471f74c4 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-01-17T14:20:49Z (GMT) No. of bitstreams: 1
MarcionilaNeliLimaDosSantos_DISSERT.pdf: 11845216 bytes, checksum: ab27f3a37cb03e804ce73ec2471f74c4 (MD5) / Made available in DSpace on 2018-01-17T14:20:49Z (GMT). No. of bitstreams: 1
MarcionilaNeliLimaDosSantos_DISSERT.pdf: 11845216 bytes, checksum: ab27f3a37cb03e804ce73ec2471f74c4 (MD5)
Previous issue date: 2017-08-14 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / O estudo da s?ntese e propriedades das nanopart?culas superparamagn?ticas vem crescendo de forma significativa ao longo dos anos, abrangendo diversas ?reas do conhecimento. A aditiva??o de nanopart?culas em ?leos minerais ? uma delas, para atuarem como lubrificantes, apresentando propriedades tribol?gicas superiores aos comerciais, reduzindo o coeficiente de atrito e o desgaste dos elementos mec?nicos. Essa disserta??o tem como finalidade estudar o desempenho tribol?gico de um ?leo mineral paraf?nico aditivado com nanopart?culas superparamagn?ticas de ?xido de ferro (SPIONs), a fim de avaliar a influ?ncia da inser??o das nanopart?culas nas propriedades tribol?gicas (coeficiente de atrito e desgaste) quando submetido a diferentes cargas e rugosidades da superf?cie. Os ensaios foram realizados no trib?metro SRV-4. Os par?metros analisados foram tamanhos de nanopart?culas (2 nm, 7 nm e 15 nm), a rugosidade da superf?cie, sendo esta polida, lixada e retificada, e a carga aplicada, no modo rampa de 30N a 250N. A caracteriza??o das nanopart?culas foi realizada por Difra??o de Raio X (DRX), Microscopia Eletr?nia de Transmiss?o (MET) e Sistema de Medidas das Propriedades F?sicas (PPMS). Quanto a caracteriza??o do ?leo puro e do ferrofluido, foi realizada por FTIR. Os valores de coeficiente de atrito foram adquiridos durante o ensaio na SRV-4. J? o desgaste da esfera AISI 52100 e do disco AISI H13 foram analisados por Microscopia Eletr?nica de Varredura (MEV), Espectroscopia Raman e Interferometria de Luz Branca, tendo como refer?ncia os resultados obtidos para o ?leo puro. As SPIONs tiveram suas melhores performances como aditivo antifric??o em baixas cargas (30N e 50N) e em superf?cie rugosa (Retificada). / The study of the synthesis and properties of superparamagnetic nanoparticles is growing up significantly along the years, allowing interaction with many knowledge. The nanoparticles additivation in mineral oils is one of them, for its performance as lubrificants, showing superior tribological properties in comparison with commercial ones, reducing the fricction coefficient and the wear of the mechanical components. The purpose of this research is to study the tribological performance of a parafinic mineral oil additived with superparamagnetic iron oxide nanoparticles (SPIONs), in order to evaluate the influence of the nanoparticles in the tribological properties (fricction coefficient and wear) when exposed to different loads and surface roughnesses differents. The tribotests were using a SRV-4 tribometer. The test parameters were the nanoparticle size (2 nm, 7 nm e 15 nm), the surface roughness, in this case polished, sanded and grounded, and the applied load steps over time (30 N ? 250 N). The nanoparticles characterization was conducted by X-Ray Diffraction (XRD), Transmission Electron Microscopy (TEM) and Physical Property Measurement System (PPMS). About the pure oil characterization and the ferroluids, was performed by FTIR. The fricction coefficient values were obtained during the tribotest in the SRV-4 tribometer. Furthermore, the AISI 52100 stell ball wear and AISI H13 steel disc wear were analyzed by Scanning Electron Microscopy (SEM), Raman Spectroscopy and White Light Interferometry (WLI), using the results obtained for pure oil as references. The SPIONs best results as antifriction additive were obtained with the low loads (30 N and 50 N) and with the rough surface (Ground).
|
112 |
Estudo do desgaste das ferramentas no microfresamento frontal /Manarelli, Flávio Henrique. January 2018 (has links)
Orientador: Alessandro Roger Rodrigues / Resumo: A microusinagem é um dos processos de fabricação capaz de produzir produtos ou geometrias de precisão e complexidade com detalhes menores que 1 mm. Contudo, para um melhor desempenho do processo de usinagem associado à qualidade do produto, entender a interação peça-ferramenta é fundamental. Esta pesquisa determinou a influência do tipo de corte e do avanço da ferramenta no desgaste da fresa (ferramenta), na energia específica de corte (processo) e na rugosidade (peça), ao empregar a operação de microfresamento de topo no aço COS AR60 de grãos ultrafinos. Os ensaios foram realizados em um centro de usinagem Romi D600 com a adaptação de um cabeçote de alta rotação (60 krpm) sem aplicação de fluido de corte. Microfresas de topo reto (Ø 800 µm) com substrato de metal duro e revestidas com TiAlN foram aplicadas nos testes. A profundidade de usinagem e a velocidade de corte foram mantidas constantes em 160 µm e 60 m/min, respectivamente. Foram variados o avanço por dente (3 e 10 µm/z) e o tipo de corte (simétrico em cheio e em face e assimétrico concordante e discordante). Análise de Variância (ANOVA) com intervalo de confiança de 95% foi aplicada a cada uma das três réplicas. Os resultados indicaram que os níveis de desgaste e a redução do diâmetro da microfresa são influenciados pelo avanço da ferramenta e tipo de corte. As maiores reduções no diâmetro (≈11%) foram devido ao impacto periódico da aresta de corte na peça e não pelo efeito de sulcamento (≈4%). Além disso, para o pe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Micro-machining is one of the processes feasible for generating geometries or parts with precision and complexity regarding dimensions smaller than 1 mm. However, the achievement of enhanced machining performance and product quality requires a prior understanding on the tool-workpiece interface. This research detemined the influence of cutting type and cutting feed on wear (tool), specific cutting force (process) and surface roughness (workpiece) when cutting the ultrafine-grained steel COS AR60 under end milling strategy. Machining tests were performed in a CNC machining centre Romi D600 provided with a high-speed spindle (60kpm) without cutting fluid application. TiAlN coated carbide endmill (Ø 800 μm) was used for straight cut with 60 m/min cutting speed, 160 μm depth of cut and feed per tooth of 3 and 10 μm. Analysis of Variance (ANOVA) with confidence interval of 95% was applied to the three runs of each cutting sets. The results have shown that tool wear levels and tool effective diameter are influenced by tool feed and cutting type. Hence, intermittent impact of tool’s cutting edges into the workpiece (≈11%) during cutting revealed to be the major cause of tool wear when compared to cutting mechanism dominated by ploughing (≈4%). Regarding experimental sets with cutting length of 98,018 m there was a predominance of tool edge chipping over abrasion and adhesion when performing face cutting with ploughing at 4.2%. On the other hand, if ploughing increases to 14.3% the m... (Complete abstract click electronic access below) / Mestre
|
113 |
Estudo do desgaste das ferramentas no microfresamento frontal / Study of tool wear in micromillingManarelli, Flávio Henrique 03 September 2018 (has links)
Submitted by Flávio Henrique Manarelli (flaviomanarelli@gmail.com) on 2018-11-01T23:57:49Z
No. of bitstreams: 1
Dissertação_Flávio Henrique Manarelli.pdf: 2986064 bytes, checksum: edc4536a4c2ec5e96e1c49c52019885f (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-11-08T19:00:53Z (GMT) No. of bitstreams: 1
manarelli_fh_me_ilha.pdf: 2986064 bytes, checksum: edc4536a4c2ec5e96e1c49c52019885f (MD5) / Made available in DSpace on 2018-11-08T19:00:54Z (GMT). No. of bitstreams: 1
manarelli_fh_me_ilha.pdf: 2986064 bytes, checksum: edc4536a4c2ec5e96e1c49c52019885f (MD5)
Previous issue date: 2018-09-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A microusinagem é um dos processos de fabricação capaz de produzir produtos ou geometrias de precisão e complexidade com detalhes menores que 1 mm. Contudo, para um melhor desempenho do processo de usinagem associado à qualidade do produto, entender a interação peça-ferramenta é fundamental. Esta pesquisa determinou a influência do tipo de corte e do avanço da ferramenta no desgaste da fresa (ferramenta), na energia específica de corte (processo) e na rugosidade (peça), ao empregar a operação de microfresamento de topo no aço COS AR60 de grãos ultrafinos. Os ensaios foram realizados em um centro de usinagem Romi D600 com a adaptação de um cabeçote de alta rotação (60 krpm) sem aplicação de fluido de corte. Microfresas de topo reto (Ø 800 µm) com substrato de metal duro e revestidas com TiAlN foram aplicadas nos testes. A profundidade de usinagem e a velocidade de corte foram mantidas constantes em 160 µm e 60 m/min, respectivamente. Foram variados o avanço por dente (3 e 10 µm/z) e o tipo de corte (simétrico em cheio e em face e assimétrico concordante e discordante). Análise de Variância (ANOVA) com intervalo de confiança de 95% foi aplicada a cada uma das três réplicas. Os resultados indicaram que os níveis de desgaste e a redução do diâmetro da microfresa são influenciados pelo avanço da ferramenta e tipo de corte. As maiores reduções no diâmetro (≈11%) foram devido ao impacto periódico da aresta de corte na peça e não pelo efeito de sulcamento (≈4%). Além disso, para o percurso de corte adotado de 98,018 m, com 4,2% da usinagem em sulcamento ou inexistente no corte em face, houve predominância de avarias por lascamento e, para o mesmo percurso, porém, com aproximadamente 14,3% do corte em sulcamento, os fenômenos predominantes no desgaste foram abrasão e adesão. O efeito do sulcamento fez com que os fatores tipo de corte e avanço, bem como suas respectivas interações, fossem significativos sobre a energia específica de corte. Os cortes em cheio e corte concordante com avanço de 3 µm/dente proporcionaram condições mais favoráveis para o microfresamento frontal, com melhor acabamento da peça e menores níveis de desgaste da ferramenta de corte. / Micro-machining is one of the processes feasible for generating geometries or parts with precision and complexity regarding dimensions smaller than 1 mm. However, the achievement of enhanced machining performance and product quality requires a prior understanding on the tool-workpiece interface. This research detemined the influence of cutting type and cutting feed on wear (tool), specific cutting force (process) and surface roughness (workpiece) when cutting the ultrafine-grained steel COS AR60 under end milling strategy. Machining tests were performed in a CNC machining centre Romi D600 provided with a high-speed spindle (60kpm) without cutting fluid application. TiAlN coated carbide endmill (Ø 800 μm) was used for straight cut with 60 m/min cutting speed, 160 μm depth of cut and feed per tooth of 3 and 10 μm. Analysis of Variance (ANOVA) with confidence interval of 95% was applied to the three runs of each cutting sets. The results have shown that tool wear levels and tool effective diameter are influenced by tool feed and cutting type. Hence, intermittent impact of tool’s cutting edges into the workpiece (≈11%) during cutting revealed to be the major cause of tool wear when compared to cutting mechanism dominated by ploughing (≈4%). Regarding experimental sets with cutting length of 98,018 m there was a predominance of tool edge chipping over abrasion and adhesion when performing face cutting with ploughing at 4.2%. On the other hand, if ploughing increases to 14.3% the main wear mechanism observed were abrasion and adhesion. Therefore, there was a significant interaction between specific cutting force and the input parameters of feed per tooth and cutting type. As a result, down-milling and channel-milling at the tool feed of 3 μm/tooth leaded to a valuable cutting performance with better workpiece surface roughness and tool wear at low levels.
|
114 |
Estimação da rugosidade gerada no processo de fresamento frontal via redes neurais artificiaisHübner, Henrique Butzlaff January 2016 (has links)
A rugosidade é um parâmetro de acabamento importante nos processos de fabricação por usinagem e é determinado de acordo com a aplicação técnica da superfície usinada. A rugosidade afeta atributos funcionais dos produtos como desgaste, atrito, reflexão da luz, capacidade de manter e espalhar um lubrificante, etc.. Como a inspeção da superfície é normalmente feita com rugosímetros após a operação de usinagem, essa tarefa consome tempo e demanda trabalho, gerando custo adicional ao produto. Assim, este trabalho tem como objetivo estimar os valores das rugosidades média (Ra) e total (Rt) geradas no processo de fresamento frontal a seco do aço SAE 1045 com fresa de topo reto via redes neurais artificiais (RNA). Dessa forma, os valores de rugosidade Ra e Rt podem ser obtidos somente informando os parâmetros do processo ao modelo. Foram considerados como variáveis de entrada do processo a velocidade de corte (vc), o avanço por dente (fz) e o raio de ponta da ferramenta (r). Após uma análise estatística, constatou-se que as variáveis de saída que melhor se correlacionavam com os valores de rugosidade foram a força média no eixo x (Fx) (direção de avanço) e a variação da força no eixo z (Fz) (direção axial). Os dados de força foram obtidos usando um sistema sensório constituído de plataforma piezelétrica, placa de aquisição de dados e computador com software apropriado. Portanto, os cinco parâmetros de entrada utilizados nos 16 modelos testados foram vc, fz, r, Fx e Fz. O algoritmo de treinamento usado foi o de Levemberg-Marquardt. Dentre os testados, os modelos com topologia 5-10-10-1 (cinco entradas e uma saída) apresentaram as melhores capacidade de estimação para os valores de Ra e Rt, mostrando a eficiência da técnica de modelagem da rugosidade por RNA. / The surface roughness is an important finishing parameter in the machining manufacturing processes and it is determined according with the technical application of the machined surface. The surface roughness affects functional attributes of parts such as wear, friction, light reflection, ability to spreading and retaining a lubricant etc. As the surface inspection is usually done with the rugosimeter after the machining operation, this task is time consuming and labor demand, generating additional cost to the product. Thus, this work aims to estimate the values of average roughness (Ra) and total roughness (Rt) generated in the dry end milling process of the SAE 1045 steel via artificial neural networks (ANN). Thus, the roughness values of Ra and Rt may be obtained only by informing the process parameters to the model. Cutting speed (vc), feed per tooth (fz) and tool nose radius (r) were considered as input variables. After statistical analysis, it was found that output variables that best correlate with roughness values were the average force on the x axis (Fx) (feed direction) and the force variation in the z-axis (Fz) (axial direction). The cutting force data signals were obtained using a sensory system composed by piezoelectric platform, data acquisition board and personal computer with appropriate software. Therefore, the five input parameters applied in the 16 models tested were vc, fz, r, Fx and Fz and the training algorithm used was the Levemberg-Marquardt. Among the models tested, those with 5-10-10-1 topology (five inputs and one output) showed the best capacity for estimation of the Ra and Rt values that can demonstrate the modeling technique effectiveness of the surface roughness using ANN.
|
115 |
Estudo de um sistema de medição a laser na análise da textura da superfície gerada por torneamentoMarchiori, Marcelo Mennet January 2013 (has links)
A determinação da rugosidade é parte fundamental para a classificação da qualidade de uma superfície. Assim, iniciou-se este trabalho realizando-se estudos a respeito de seus métodos de medição. Devido à grande adaptabilidade e à velocidade dos métodos a laser, os estudos foram direcionados para estes tipos de técnicas de medição. Verificou-se que esses dispositivos vinculavam-se a sistemas em que o laser refletido era analisado através de sistemas com detectores do tipo CCD, em que a imagem refletida era analisada num todo. Assim, a bibliografia trouxe inspiração para mensurar a rugosidade de uma superfície gerada por torneamento horizontal, a partir da intensidade laser refletida. Propôs-se, então, um método baseado exclusivamente, na intensidade do sinal que era refletido pela superfície em estudo, a contar de uma incidência normal, já que aos autores ressaltavam que quanto maior a rugosidade da superfície menor seria o sinal refletido por ela. O sistema foi montado e sua capacidade de diferenciar distintas rugosidades foi testada. Então foram produzidas amostras com diferentes rugosidades, a fim de se obter uma função que pudesse correlacionar o sinal laser com a respectiva rugosidade (medida esta feita em rugosímetro de agulha). A função de transferência encontrada foi testada em amostras dissemelhantes das que a geraram, com o intuito de comprovar sua eficácia. Amostras fabricadas com ferramentas distintas de corte também foram produzidas e submetidas ao mesmo procedimento. As funções de transferência geradas alcançaram sucesso na previsão da rugosidade em, no máximo, 16,6% dos pontos, considerando uma margem de erro de 20%. A seguir, procurando-se os motivos que pudessem ter causado este percentual, levantou-se a possibilidade de estarem ocorrendo efeitos ópticos capazes de causar interferências devido às irregularidades na superfície. Efeitos capazes de degenerarem o sinal refletido. A comprovação de que o sinal eventualmente poderia estar sendo perturbado aconteceu através de referência bibliográfica e de imagens obtidas por microscopia eletrônica de varredura, em que se pôde observar a existência de estruturas na face das amostras que seriam isolada ou conjuntamente capazes de causar os efeitos citados. / The determination of the roughness is a key for a good classification of a surface. Thereby, the work was started with a study about the roughness measurements methods. Due to the great adaptability and speed of laser methods, the studies were directed to these kinds of measurement techniques. It was observed in the literature that these laser devices were linked to systems where the reflected laser was analyzed by systems with CCD detectors, where the reflected image was entirely analyzed. Hence, the bibliography brought inspiration to measure the surface roughness generated by axial turning from the intensity of the reflected laser. It was proposed then a measurement method exclusively based on the intensity of the signal that was reflected by the surface under study, because the authors noted that as the roughness of surface became bigger as the signal reflected is became smaller. The proposed system has been assembled and ability to distinguish different roughness was tested successfully. Then samples were produced with different roughness in order to obtain a function that would correlate the laser signal with its roughness (this measurement is made by tactile measurement instrument). The transfer function obtained was tested on different samples that generated in order to prove its efficacy. Samples produced with different cutting tools were also produced and subjected to the same procedure. The transfer functions reached a successful prediction of the roughness maximum for 16.6% of the points assuming a margin of error of 20%. So, looking up the reasons that could have caused this percentage we think the possibility as the occurrence of some optical effects that can cause interference due to irregularities on the surface. These optical effects can degenerate the reflected signal. The proof that the signal could possibly be corrupted was made by the bibliographic references and some images obtained by scanning electron microscopy in which they could observe the existence of structures on the sample surfaces that would can be a reason for these effects individually or together.
|
116 |
Influência dos procedimentos de clareamento dental na adesão de acessórios ortodônticos / Influence of dental bleaching on shear bond strength of orthodontic bracketsMariana Martins e Martins 20 February 2008 (has links)
Os agentes clareadores, principalmente aqueles em alta concentração, podem provocar alterações químico-estruturais e morfológicas no esmalte dental. O objetivo desta pesquisa foi avaliar a influência do peróxido de hidrogênio a 35% na adesão de bráquetes ortodônticos colados nos tempos correspondentes a zero e 24 horas e, 7, 21 e 56 dias após a realização do clareamento dental e na morfologia do esmalte dental. Foram utilizados 150 incisivos bovinos dos quais, 120 foram utilizados para confecção dos corpos de prova para os testes de cisalhamento, determinação do índice de adesivo remanescente (ARI) e avaliação da rugosidade superficial do esmalte. Os 30 incisivos restantes foram utilizados para avaliação morfológica do esmalte clareado em microscopia eletrônica de varredura (MEV). O agente clareador utilizado foi o peróxido de hidrogênio a 35% (Whiteness HP FGM ) e o adesivo, o Transbond XT (3M Unitek ). Foram aplicados os testes de Kruskal-Wallis e Mann-Whitney, para avaliação dos resultados referentes às tensões de cisalhamento e valores dos índices ARI e testes T Student e ANOVA para a rugosidade, todos adotando p<0,05. As médias obtidas nos testes de cisalhamento foram: 7,472,18 MPa (controle), 1,350,44 MPa (zero hora), 7,812,54 MPa (24 horas), 9,322,33 MPa (7 dias), 7,312,20 MPa (21 dias) e 6,671,77 MPa (56 dias). Foram constatadas diferenças significativas entre todos os grupos analisados (p<0,001) e de forma pareada nos grupos zero hora (p<0,001) e 7 dias (p=0,027) em relação ao controle e entre zero e 24 horas (p<0,001). O índice ARI (0, 1, 2 e 3) também apresentou diferenças significativas entre todos os grupos (p = 0,011) e na comparação de todos os grupos experimentais com o grupo controle: zero hora (p = 0,001), 24 horas (p = 0,009), 7 dias (p = 0,018), 21 dias (p<0,001) e 56 dias (p = 0,004). Em relação ao grupo controle, o valor da tensão de cisalhamento reduziu de forma significativa, quando a colagem foi realizada logo após o clareamento dental, recuperando-se rapidamente em 24 horas. Tornou-se significativamente maior em 7 dias e, nas semanas seguintes (21 e 56 dias), retornou a valores normais. Em relação ao índice de adesivo remanescente, os procedimentos de clareamento dental promoveram diferentes padrões de fratura da interface esmalte/adesivo/bráquete. O grupo controle apresentou alta incidência de índice 3 (fratura na interface bráquete/adesivo) e nenhum índice 0 (fratura adesiva); comportamento oposto foi observado nos grupos experimentais, com baixa incidência de índice 3 e alta de índice 0. Não foram encontradas diferenças significativas na rugosidade superficial e nem alterações microscópicas na morfologia do esmalte dental dos grupos analisados. / Elementary-chemical and morphological changes may occur in enamel surface by the use of bleaching agents, especially by the higher concentrations. The purpose of this research was to investigate the influence of 35% hydrogen peroxide on orthodontic bracket adhesion at zero hour, 24 hours, 7, 21 and 56 days after dental bleaching and investigate the alterations in enamel morphological structures. Bovine incisors were used in a total of 150, which 120 were prepared for adhesion test, adhesive remnant index (ARI) determination and roughness test. The 30 left were used for morphologic observation of bleached enamel in scan electron microscopy (SEM). The 35% hydrogen peroxide was used as a bleaching agent (Whiteness HP FGM) and the Transbond XT (3M Unitek) as a bonding agent. The Kruskal-Wallis and Mann-Whitney tests were applied for adhesion test and evaluation of ARI scores and the Student T test and ANOVA for roughness test, all adopting p < 0.05. The means of shear bond strength values were 7.472.18 MPa (control), 1.350.44 MPa (zero hour), 7.812.54 MPa (24 hours), 9.322.33 MPa (7 days), 7.312.20 MPa (21 days) e 6.671.77 MPa (56 days). Statiscally significant differences were observed between all the groups (p < 0.001) and were observed in the comparison of zero hour (p < 0.001) and 7 days (p < 0.027) with the control group and in the comparison of zero and 24 hours (p < 0.001). ARI scores (0, 1, 2 e 3) also showed statiscally differences between all the groups (p = 0.011) and at the comparison of all the experimental groups with the control: zero hour (p = 0.001), 24 hours (p = 0.009), 7 days (p = 0.018), 21 days (p<0.001) e 56 days (p = 0.004). In respect to the control group, the shear bond strength values became significantly lower when the bracket was bonded immediately after bleaching and quickly returned to control level in 24 hours. In 7 days became higher and recovered to normal values in the next weeks (21 and 56 days). Different patterns of enamel/adhesive/bracket fractures were observed in bleached enamel when ARI scores were analyzed. The control group showed a high frequency of 3 score (adhesive/bracket fracture) and none of zero score (adhesive fracture), the opposite behavior was observed in the experimental groups, with low frequency of 3 score and high of zero score. No statiscally differences were noted at roughness test and no effects on the surface morphology were observed in the dental enamel of all groups studied at SEM analysis.
|
117 |
Avaliação da influência de um gel a base de peróxido de hidrogênio a 35% sobre a rugosidade superficial de três resinas compostas fotopolimerizáveis de diferentes tamanhos médios de partículas / Evaluation of influence of a gel-based hydrogen peroxide 35% on the surface roughness of three composite resins of different sizes of particlesAndré Fábio Vasconcelos Moro 19 December 2007 (has links)
O clareamento dental se firmou na odontologia como o meio disponível mais simples, comum e conservador de devolver o padrão de cor almejado pelos pacientes. O processo clareador consiste em um ataque a superfície do substrato dentário, provocando pequenas alterações através da quebra de pigmentos, que são longas cadeias de carbono, originando cadeias moleculares cada vez menores até que possam ser eliminadas por difusão. Considerando-se a prática clínica diária nota-se que, algumas vezes, o agente clareador entra em contato com materiais restauradores que ali se encontram, como as resinas compostas por exemplo. Tal procedimento pode ocasionar a indicação de substituição da resina em boas condições clínicas, devido à diferença de cor entre o dente clareado e o compósito. Porém, há casos, como por exemplos: restaurações posteriores e manutenção de clareamento, em que a cor não seria fator decisivo para uma intervenção clínica sobre a restauração. Este estudo avaliou, através de microscopia de força atômica, o efeito de um protocolo de clareamento dentário de consultório a base de peróxido de hidrogênio 35% sobre a rugosidade superficial de três resinas de tamanhos de partículas diferentes (micro-híbrida, microparticulada e nanoparticulada). Vinte e quatro imagens de 5 X 5μm selecionadas aleatoriamente e geradas por microscopia de força atômica foram analisadas estatisticamente por ANOVA e pelo teste SNK (p< 0,05). A análise das topografias demonstrou a resina microparticulada com a menor rugosidade inicial (Rq: 19,22μm e Ra: 14,95μm) e final (Rq: 28,66μm e Ra: 23,06μm), sendo a final semelhante estatisticamente a nanoparticulada inicial (Rq: 29,60μm e Ra: 23,75μm). Seguiram a micro-híbrida inicial (Rq: 35,45μm e Ra: 26,22μm) e a nanoparticulada final (Rq: 40,22μm e Ra: 31,49μm). A resina micro-híbrida final apresentou a maior rugosidade (Rq: 47,41μm e Ra: 36,45μm). Um aumento uniforme e proporcional da rugosidade de superfície nas três resinas testadas foi constatado. Em uma segunda etapa do estudo, a mesma área de superfície foi avaliada antes e depois do procedimento simulador de clareamento e o resultado foi semelhante, porém com a visualização das localidades afetadas. / The bleaching has been in dentistry as the simplest, common and conservative way to return of the pattern of color desired by the patients. The bleaching consists in an attack on dental surface breaking pigments, which are long chains of carbon, causing molecular chains ever smaller until it can be eliminated by diffusion. Considering the practice daily, the bleaching agent contacts restorative materials, such as composite resins for example. This procedure can appoint the replacement of the resin in good clinical conditions due the difference in color between the cleared tooth and composite. But there are cases, for examples: posterior restoratives and maintenance of bleaching, in which color would not be decisive factor for a clinical intervention on the restoration. This study evaluated, through atomic force microscopy, the effect of a memorandum of an in office dental bleaching by hydrogen peroxide 35% on the surface roughness of three types of resins of different sizes of particles (micro-hybrid, microparticles and nanoparticles). Twenty four images of 5 X 5μm randomly selected and generated by atomic force microscopy, were statistically analyzed by ANOVA and the SNK test (p< 0.05). The analysis of topographies showed the microfilled resin with lower initial roughness (Rq: 19.22μm and Ra: 14.95μm) and final roughness (Rq: 28.66μm and Ra: 23.06μm), with the final roughness statistically similar to initial roughness of nanoparticles resin (Rq: 29.60 μm and Ra: 23.75μm). Followed the initial roughness of micro-hybrid resin (Rq: 35.45 μm and Ra: 26.22 μm) and the final roughness of nanoparticles resin (Rq: 40.22μm e Ra: 31.49μm). The final roughness of micro-hybrid resin had the highest roughness (Rq: 47.41 μm and Ra: 36.45 μm). An uniform and proportional increase of surface roughness of the three resins tested was found. A second stage of the study evaluated the same area of surface before and after the procedure simulator of bleaching and the result was the same, with the view of the affected localities.
|
118 |
Avaliação do efeito de diferentes agentes clareadores na rugosidade superficial e estabilidade de cor de dois compósitos / In vitro evaluation of different bleaching agents on the roughness and color stability of two dental compositesAnna Paula Kalix França Mendes 13 February 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar, in vitro, o efeito de dois clareadores a base de peróxido de hidrogênio a 10% e a 35%, Rembrandt Whitening Pen/Oral B e Whiteness HP Maxx/FGM na estabilidade de cor e rugosidade superficial de dois compósitos, sendo um nanohíbrido TPH3/ Dentsply e outro nanoparticulado Filtek Z350/3M ESPE. Foram confeccionados 40 corpos de prova a partir de uma matriz de aço inox com dimensões de 21,0 mm de diâmetro e 2,00 mm de profundidade e divididos em dois grupos conforme o compósito a ser avaliado e submetidos aos seguintes experimentos: Exp. I Ação dos agentes clareadores na estabilidade de cor dos compósitos; Exp. II - Ação dos agentes clareadores na rugosidade superficial dos compósitos; Exp. III - Ação do polimento de superfície na rugosidade superficial e retomada de cor dos compósitos. Tanto a rugosidade como a estabilidade de cor foi avaliada em rugosímetro Mitutoyo SJ 201P e Espectofotômetro de Reflectância Perkin Elmer Lambda 35 UV/VIS respectivamente durante as seguintes etapas do experimento: T0 - após a confecção dos corpos de prova, T1 - após envelhecimento acelerado das amostras por 24 horas por luz ultravioleta, T2 - após submetidas a dois corantes: café e açaí por 7 dias, T3 - após submetidas aos agentes clareadores e T4- após polimento das mesmas. Durante todo o experimento os corpos de prova foram mantidos em saliva artificial e estufa calibrada a 37oC. Os resultados foram tratados estatisticamente por ANOVA e testes de Tukey, comparações múltiplas de Bonferroni e SNK com 5% de significância. Não foram observadas diferenças estatisticamente significantes entre os corantes, o mesmo acontecendo quando os clareadores foram comparados por Teste-t de Student com 5% de significância. Baseado nos resultados obtidos pôde-se concluir que o compósito TPH3 foi mais afetado pelos corantes que o compósito Z350. Os agentes clareadores não foram capazes de promover clareamento dos compósitos nos tempos testados, porém o polimento possibilitou retorno à condição de cor inicial (envelhecida) para o compósito TPH3 o mesmo não acontecendo para o Z350. O polimento não determinou retorno à condição original de rugosidade para qualquer dos compósitos. / The objective of this study was to evaluate, in vitro, the effects of two commercially available bleaching agents containing hydrogen peroxide, Rembrandt Whitening Pen/Oral B and Whiteness HP Maxx/FGM, on the surface roughness and on color change of two composites (TPH3/Dentsply and Filtek Z350/3M ESPE). Twenty specimens of each material were constructed by using a stainless matrix, measuring 21.0 mm diameter and 2.00 mm depth and divided in three groups according the experiments. Group I- effect of the bleaching agents on the composites color change; Group II- effect of the bleaching agents on surface roughness; Group III- effect of polishing procedures on the surface roughness and on color change of the composites. The color measurements were done using a reflectance spectrophotometer Perkin Elmer Lambda 35 UV/VIS according to the CIE L*a*b* color scale and the roughness measurements were obtained using a digital Mitutoyo rugosimeter SJ 201P. The measurements were made in five times: T0: after the specimen preparation; T1: after accelerated aging for 24 hours UV light; T2: after immersed for 07 days at 37o C in either coffee or açaí (a typical fruit of North of Brazil); T3: after bleaching procedures and T4: after finishing and polishing. The results were statistical treated by ANOVA and the differences treated by Tukey, Bonferroni`s test and SNK with 5% of significance. According t-Test with 5% of significance, there were no differences between the staining (coffee and açaí) and neither between the bleaching agents tested. The composite TPH3 showed higher values of discoloration when compared with Filtek Z350, The bleaching agents were not able to improve any kind of whitening on the composites surface. The polishing procedures after bleaching were effective on return the TPH3 to its original color, but they were not capable to return the original roughness of both of the composites.
|
119 |
Influência da aplicação de selantes de superfície na perda de massa e alteração da rugosidade superficial de um compósito após aplicação tópica de flúor fosfato acidulado e ensaio de escovação / Influence of the application of surface sealants on weight loss and change of surface roughness of a composite after topical application of acidulated phosphate fluoride and toothbrushing assayBianca Mataveli Vimercati 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo teve por objetivo avaliar a degradação de um compósito após ciclos de escovação simulada, com ou sem a aplicação de selantes de superfície e com ou sem a aplicação tópica de flúor fosfato acidulado (FFA). A avaliação foi feita através da análise alteração da massa e da rugosidade superficial. Foram confeccionados 80 corpos-de-prova (CP) com o compósito Z250 (3M) (8mm x 3mm) e divididos em 4 grupos. Todos os grupos tiveram as superfícies regularizadas com lixa dágua 1.200. O grupo A (controle) não recebeu selamento, o grupo B recebeu aplicação do selante de superfície Fortify (Bisco), o grupo C, BisCover (Bisco) e o grupo D, Fill Glaze (Vigodent). Após isso, os CP foram armazenados em água destilada por 7 dias, em temperatura ambiente e, posteriormente, pesados em balança analítica para obtenção da massa inicial e submetidos à análise da rugosidade superficial inicial, utilizando rugosímetro Surftest SJ 201 P Mitutoyo. Os grupos A, B, C e D foram subdivididos em 2 grupos cada (n:10) e um subgrupo da cada grupo inicial (A2, B2, C2 e D2) foi submetido à aplicação de FFA (4 min), antes da escovação. Os grupos A1, B1, C1 e D1 permaneceram em água destilada. Após a remoção do FFA, todos os grupos foram armazenados em saliva artificial por 1 hora, em temperatura ambiente. Posteriormente foram submetidos a 30.000 ciclos de escovação, representando 6 meses de escovação diária. Foi utilizada escova dental macia (Ultra) e uma solução de creme dental (Colgate Máxima Proteção Anticáries) e água destilada na proporção de 1:2. Ao fim do ensaio, os CP foram lavados em água corrente por 5 minutos, secos com papel absorvente, pesados novamente para obtenção da massa final e submetidos à análise da rugosidade superficial final. O desgaste de cada CP foi avaliado através da perda de massa, que foi calculada pela diferença das pesagens antes e após a escovação e a alteração da rugosidade superficial foi calculada pela diferença entre os valores das médias de rugosidade superficial inicial e final. Algumas amostras foram analisadas em microscópio de força atômica com finalidade ilustrativa. Os dados obtidos foram tratados estatisticamente. Na análise da alteração de massa, quando comparado os grupos isoladamente, somente o grupo D1(FIL) não sofreu alteração de massa significativa. As comparações entre as médias de alteração de massa dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa somente nas comparações: A1(CONT)xB1(FFY) e B1(FFY)xD1(FIL). Para os grupos que receberam FFA, não houve diferença significativa entre as médias de alteração de massa. Na análise da alteração de rugosidade superficial, quando comparado os grupos isoladamente, houve aumento significativo de rugosidade superficial nos grupos A2(FFA), B2(FFY+FFA), C1(BIS) e C2(BIS+FFA). As comparações entre as médias de alteração de rugosidade superficial dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa apenas na comparação: C1(BIS)xD1(FIL). Para os grupos que receberam FFA, as comparações A2(FFA)xD2(FIL+FFA); B2(FFY+FFA)xD2(FIL+FFA); C2(BIS+FFA)xD2(FIL+FFA) mostraram diferenças significativas. Não foi observada correlação estatisticamente significante entre a alteração de massa e rugosidade superficial entre os grupos analisados. Com base nos resultados obtidos e na análise estatística realizada, pôde-se concluir que a aplicação de FFA e a aplicação de selantes de superfície não tiveram influência na alteração de massa e na rugosidade superficial dos materiais testados. O selante de superfície Fortify não protegeu o compósito após escovação, apresentando uma maior perda de massa no grupo B1 (Fortify) em comparação com o grupo A1 (controle). Os demais selantes testados protegeram o compósito. Não existiu correlação significativa entre perda de massa e alteração da rugosidade. / The aim of this study was to assess the degradation of a composite after simulated toothbrushing cycles, with or no applying surface sealants and with or no topical application of acidulated phosphate fluoride (APF). The assessment was made by analysis of change of weight and of surface roughness. Eighty specimens were made with the Z250 composite (3M) (8 mm x 3 mm) and divided in 4 groups. All the groups have their surfaces regularized with sandpapers 1.200 under water. The group A (control) have not seal, in the group B was applied the surface sealant Fortify (Bisco), in the group C the BisCover (Bisco), and in the group D the Fill Glaze (Vigodent). Following, the specimens were stored in distilled water for 7 days at room temperature and, subsequently, they were weighted in analytical scales for obtaining initial weight and subjected to analysis of initial surface roughness using the Surftest SJ 2001 P Mitutoyo profilometer of surface roughness. The groups A, B, C and D were subdivided in 2 groups each (n = 10) and a subgroup of every initial group (A2, B2, C2, D2) was subjected to application of APF (for 4 minutes) before the toothbrushing. The groups A1, B1, C1 and D1 remained in distillated water. After the removal of the APF, all the groups were stored in artificial saliva for 1 hour at room temperature. Subsequently they were subjected to 30000 cycles toothbrushing, representing 6 months of daily toothbrushing. The soft toothbrush (Ultra) and a toothpaste (ColgateCavity Protection) and distillated water in ratio 1:2 were used. At final of assay, the specimens were washed in running water for 5 minutes, dried with absorbent paper, measured again in order to obtain the final weight, and they were subjected to analysis of final surface roughness. The wear of each specimen was assessed by weight loss, which was calculated by difference of measuring before and after toothbrushing, and the change of surface roughness was calculated by difference between the values of initial and final surface roughness. Some samples were analysed in atomic force microscope with illustrative purpose. The data were treated statistically. In the analysis of weight change, when compared to groups separately, only the group D1 (FIL) have no significant weight change. The comparisons between the means of weight change of groups with or no APF showed there are no significant differences between all the comparisons: A1 (CONT) X B1 (FFY) and B1 (FFY) x D1 (FIL). For the groups with APF, there are no significant differences between the means of weight change. In the analysis of surface roughness change, when compared to groups separately, there was a significant increase of surface roughness in groups A2 (APF), B2 (FFY + APF), C1 (BIS) and C2 (BIS + APF). The comparisons between the means of surface roughness change of the groups with and no APF revealed there no differences significant between all of comparisons. For the groups with no APF, there was significant difference only in comparison C1 (BIS) x D1 (FIL). For the groups with APF, the comparisons A2 (APF) x D2 (FIL + APF), B2 (FFY + APF) x D2 (FIL + APF), C2 (BIS + APF) x D2 (FIL + APF) showed significant differences. It wasnt noted correlation significant statistically between weight change and surface roughness between the groups analyzed. With basis on findings obtained and in the statistical analysis accomplished, it could to conclude that the application of APF and the use of surface sealants have not influence on the weight change and surface roughness of composite tested. The surface sealant Fortfy have not protected the composite after toothbrushing, showing the higher weight loss in the group B1 (Fortfy) when compared to group A1 (control). The remainder sealants tested has protected the composite. There wasnt significant correlation between weight loss and roughness change.
|
120 |
ANÁLISE DA RUGOSIDADE SUPERFICIAL DO ESMALTE HUMANO EXPOSTO OU NÃO À AÇÃO DE AGENTE CLAREADOR APÓS ESCOVAÇÃO COM DIFERENTES DENTIFRÍCIOS / ANALYSIS OF SURFACE ROUGHNESS OF THE HUMAN ENAMEL EXPOSED OR NOT THE ACTION OF BLEACHING AGENT AFTER BRUSHING WITH DIFFERENT DENTIFRICESPachaly, Raquel 16 December 2009 (has links)
The aim this study was to evaluate, in vitro, the average surface roughness (Ra) of human enamel exposed or not to the action of bleaching agent with carbamide peroxide (CP) 10% after brushing with different dentifrices. Ninety-six (96) specimen enamel was used and divided into two groups: GI- exposed to the action of bleaching agent and GII- non exposed to the action of bleaching agent and subdivided into eight subgroups of brushing: (CEW) Close-Up Extra Whitening, (CUB) Colgate Ultra White (CPC) Crest Cavity Protection and (DW) deionized water. The specimens from the GI group were submitted to the bleaching treatment with
PC10% for 6h during14 days; the GII group were stored in artificial saliva for 14 days. After this period the groups were subjected to 35,600 cycles in the mechanical
toothbrushing machine equivalent to 2 years and a half of the normal brushing, using the Oral-B toothbrush. The Ra was measured before and after brushing with Mitutoyo
SJ 201P perfilometer. The results were submitted to ANOVA and Tukey test (5%) and indicated that there is not significant difference in Ra between GI and GII.
Among the subgroups of brushing, it might be observed a significant increase of the roughness for the CEW subgroup with statistical difference for the CUB subgroup.
The subgroups CCP and DW presented intermediate values of Ra not differing from the other subgroups of brushing. These results are related to different abrasives
which are present in the composition of dentifrice once the abrasiveness of the dentifrice depend particle hardness, shape, size, size distribution and concentration. / O objetivo deste trabalho foi avaliar in vitro a rugosidade superficial média (Ra) do esmalte humano exposto ou não à ação de agente clareador com peróxido de carbamida (PC)10% após escovação com diferentes dentifrícios. Foram utilizados 96 espécimes de esmalte divididos em 2 grupos: GI- exposto à ação de gel clareador e GII- não exposto à ação de gel clareador e subdivididos em 8 subgrupos de escovação: (CEW) Close-Up Extra Whitening, (CUB) Colgate Ultra
Branco, (CCP) Crest Cavity Protection e (AD) Água Deionizada. Os espécimes do grupo GI foram submetidos ao tratamento clareador com PC10% por 6h/14 dias; os
do grupo GII ficaram armazenados em saliva artificial por 14 dias. Decorrido este período, os grupos foram submetidos à 35.600 ciclos em máquina de escovação mecânica que corresponde a 2 anos e meio de escovação normal, utilizando escova Oral-B. A Ra foi medida antes e depois da escovação com um Rugosímetro Mitutoyo SJ 201P. Os resultados foram submetidos à ANOVA e ao Teste de Tukey (5%) e indicaram que não existe diferença significativa de Ra entre os grupos GI e GII. Entre os subgrupos de escovação pode-se observar um aumento significativo da rugosidade para o subgrupo CEW com diferença estatística para o subgrupo CUB. Os subgrupos CCP e AD apresentaram valores intermediários de Ra, não diferindo dos demais subgrupos de escovação. Esses resultados estão relacionados com os diferentes abrasivos presentes na composição dos dentifrícios uma vez que a
abrasividade do dentifrício depende da dureza, forma, tamanho, amplitude da distribuição e concentração das partículas.
|
Page generated in 0.0543 seconds