Spelling suggestions: "subject:"rugosidade"" "subject:"rugosidades""
151 |
Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio / Effects of sterilization and clinical use in mechanical properties and surface roughness of nickel titanium wiresPrado, Murilo de Melo 25 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-21T11:25:26Z
No. of bitstreams: 2
Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-21T11:40:15Z (GMT) No. of bitstreams: 2
Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-10-21T11:40:15Z (GMT). No. of bitstreams: 2
Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-03-25 / This study evaluated the effects of sterilization and clinical use in the mechanical properties
and surface roughness gauge wires 0.018 "nickel titanium termoset, with the addition of
copper covers: Ormco (Glendora, CA, USA). Twenty-four samples were the evaluation of
mechanical behavior in the load test and deflection, the scanning electron microscopy and
atomic force microscope to check surface roughness. The tests were performed in four
different situations: 1-packaged by the manufacturer (control); 2- packaged by the
manufacturer and autoclaved; 3- after clinical use 60 days and disinfection and 4- and
autoclaved clinical use. The data were submitted to ANOVA and Tukey test. By applying the
deflection test on three points could be observed that the wires in all groups showed
mechanical behavior in the activation / deactivation similar, with no significant statistical
differences. All wires reached the end point of deactivation with forces approximate the
control group (1.398 ± 0.19 N / mm). The AFM and SEM, all thermoset wires showed
irregularities in its surface topography, and there were no major changes in surface pattern
between the groups for the analyzed wire. The qualitative evaluation of surface roughness
showed grooves and craters, influencing the surface of the wires smoothness, while the
quantitative analyzes showed no statistically significant difference between the groups
evaluated. The concluse is that sterilize the wires and use them clinically for 60 days did not
alter the mechanical behavior and the surface roughness of the wires 0.018" NiTi Thermoset
with addition of copper. / Este estudo avaliou os efeitos da esterilização e uso clínico nas propriedades mecânicas e
rugosidade superficial de fios calibre 0,018” de níquel titânio termoativado com adição de
cobre da marca: Ormco (Glendora, CA, USA). Vinte e quatro amostras foram submetidas à
avaliação do comportamento mecânico no teste de carga e deflexão, à microscopia eletrônica
de varredura e microscópio de força atômica para verificação da rugosidade superficial. Os
testes foram realizados em quatro situações distintas: 1- embalado pelo fabricante (controle);
2- embalado pelo fabricante e autoclavado; 3- após uso clínico 60 dias e desinfecção e 4- uso
clínico e autoclavado. Os dados obtidos foram submetidos à análise estatística ANOVA e
teste de Tukey. Pela aplicação do teste de deflexão em três pontos pôde-se observar que os
fios em todos os grupos apresentaram comportamento mecânico na ativação/desativação
semelhantes, não havendo diferenças estatísticas significantes. Todos os fios chegaram ao
ponto final de desativação com forças aproximadas ao grupo controle (1,398 ±0,19 N/mm).
Ao AFM e MEV, todos os fios termoativados apresentaram irregularidades em sua topografia
superficial, não sendo observadas grandes mudanças no padrão superficial entre os grupos
para cada fio analisado. A avaliação qualitativa da rugosidade superficial demonstrou
ranhuras e crateras, influenciando na lisura superficial dos fios, enquanto a avaliação
quantitativa demonstrou não haver diferença estatisticamente significante entre os grupos
avaliados. Concluiu-se que esterilizar os fios e utilizá-los clinicamente por 60 dias não alterou
o comportamento mecânico e nem a rugosidade superficial dos fios 0,018” NiTi
termoativados com adição de cobre.
|
152 |
Avaliação in vitro da rugosidade superficial de resinas compostas, comparando diferentes sistemas de acabamento e polimento e após a profilaxia com jato de bicarbonato / In vitro evaluation of surface roughness of different composite resins, comparing different finishing and polishing systems and after prophylaxis with bicarbonate jetCarol Brandt Alves 04 October 2012 (has links)
A presente pesquisa in vitro teve como objetivo avaliar a ocorrência de alterações superficiais em três resinas compostas disponíveis comercialmente quando submetidas a tratamentos de polimento e jato de bicarbonato. As alterações foram quantificadas através de análises rugosimétricas e qualificadas através de microscopia eletrônica de varredura. Foram testadas três resinas compostas:nanoparticulada Z350 (3M ESPE, Saint Paul- MN, EUA), microhíbrida Z250 (3M ESPE, Saint Paul- MN, EUA) emicroparticulada Durafill (Heraeus Kulzer, Germany). Para cada resina foram confeccionados quinze corpos de prova com o auxílio de uma matriz aço inox com 7mm de diâmetro e 3 mm de espessura em dois incrementos e fotoativadas seguindo as orientações do fabricante. Os corpos de prova foram mantidos em água destilada a 37°C por 24 horas. Em seguida foram sub divididos em três grupos de acordo com protocolos de acabamento e polimento sendo avaliados o polimento com pontas Enhance® + PoGo (Dentsply, Konstanz, Germany), pontas Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) e discos Sof Lex Pop On (3M ESPE, Saint Paul- MN, EUA). Todos os espécimes foram submetidos à ciclagem térmica de 5 a 55 °C com tempo de imersão 1 minuto por 1000 ciclos. Após a ciclagem os espécimes foram submetidos a jato de bicarbonato (equipamento Ortusonic Ortus, Campo Mourão, PR, Brasil) por 30 segundos. A rugosidade de superfície foi avaliada com o auxílio de uma aparelho rugosímetro ( Mitutoyo SJ- 201P Mitutoyo Tokyo, Japão) em três momentos, sendo a primeira leitura, baseline, realizada após 24hs da confecção dos corpos de prova. A segunda, após o polimento dos corpos de prova e a terceira, após a profilaxia com jato de bicarbonato. A rugosidade foi medida em cinco locais diferentes em cada espécime. Os resultados foram analisados levando em consideração a rugosidade média (Ra), em micrômetros (m). Posteriormente foram realizadas análises ao microscópio eletrônico de varredura. De acordo com a metodologia empregada, conclui-se que a resina que apresentou maior rugosidade de superfície foi a microparticulada (Durafill), as menores rugosidades foram observadas nas resinas compostas nanoparticulada (Z350) e microhibrida (Z250). Os discos Sof Lex Pop On e as pontas Enhance e PoGo produziram superfícies mais lisas do que o sistema de polimento com as pontas Astropol, tais resultados podem ser confirmados com a análise em Microscopia Eletrônica de Varredura (M.E.V). / This in vitro study aimed to evaluate the occurrence of surface changes in three commercially available resin composites when subjected to polishing treatments and bicarbonate jet. The changes were quantified through roughness analysis and qualified by scanning electron microscopy. We tested three composites: nanoparticulated Z350 (3M ESPE, St. Paul, MN, USA), microhybrid Z250 (3M ESPE, St. Paul, MN, USA) e microparticuladed Durafill (Heraeus Kulzer, Germany). For each resin were prepared fifteen test specimens with the aid of a stainless steel matrix with 7mm diameter and 3 mm thick and photoactivated in two increments following the manufacturer\'s instructions. The specimens were kept in water at 37 ° C for 24 hours. Then were divided into three groups according to protocols being evaluated finishing and polishing polishing tips with Enhance ® + PoGo (Dentsply, Konstanz, Germany), tips Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) and Sof Lex Pop On disks (3M ESPE, St. Paul, MN, USA). All specimens were subjected to thermal cycling 5-55 ° C with a soak time of 1 minute per 1000 cycles. After cycling the specimens underwent bicarbonate jet (Ortusonic Ortus equipment, Campo Mourao, Parana, Brazil) for 30 seconds. The surface roughness was evaluated with the aid of a machine rugosimeter (Mitutoyo Mitutoyo SJ-201P Tokyo, Japan) in three stages, with the first reading, baseline, performed 24 hours after the making of the specimens. The second, after polishing the samples and the third, after prophylaxis with bicarbonate jet. The roughness was measured at five different locations on each specimen. The results were analyzed taking into account the average roughness (Ra) in micrometers (mm). Later analyzes were performed by scanning electron microscope. According to the methodology, it is concluded that the resin with the highest surface roughness was microparticulated (Durafill), the lowest roughness was observed in nanoparticled composites (Z350) and microhybrid (Z250). The Sof Lex Pop On disks and tips Enhance and PoGo produced smoother surfaces than polishing system with tips Astropol, these results can be confirmed with the analysis in Scanning Electron Microscopy (SEM).
|
153 |
Avaliação comparativa da resistência à abrasão de resinas compostas "condensáveis", submetidas à escovação simulada, através da alteração de massa e da rugosidade superficial. / "In vitro" ëvaluation of abrasion resistance of "condensable" composite resins after toothbrushing. Wear and superficial roughness analysis.Linda Wang 02 March 2001 (has links)
Resinas compostas "condensáveis" correspondem a uma nova categoria de material restaurador posterior especialmente desenvolvida como alternativa estética ao amálgama. O objetivo deste trabalho foi comparar algumas marcas comerciais Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) e Filtek P-60 (P-60) a dois grupos controles, Silux Plus (SP), de micropartículas, e Z100 (Z), microhíbrida, por meio de um teste in vitro de escovação simulada. Doze corpos-de-prova de cada material foram confeccionados com dimensões de 5mm de diâmetro por 3mm de espessura. Foram realizados 100.000 ciclos de escovação em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e solução de dentifrício e água deionizada. A alteração de massa foi verificada pela diferença entre as médias de massa inicial (antes da escovação) e final (depois da escovação) em balança analítica Sartorius. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 e por meio de microscopia eletrônica de varredura. Os resultados obtidos foram submetidos à análise de ANOVA e Tukey, apresentando diferenças significantes para perda de massa e alteração de rugosidade. As resinas SureFil e Alert apresentaram menor alteração de massa (0,38% e 0,52%), enquanto Solitaire, Prodigy Condensable e Silux Plus as maiores (1,51%, 1,55%, 1,70%). Z100 e P-60 apresentaram alteração de massa intermediária às outras resinas. Diferentemente dos outros grupos, Prodigy Condensable, Solitaire e Z100 apresentaram, após a escovação, superfícies mais lisas (-0,012mm, -0,047mm e -0,065mm respectivamente), enquanto a rugosidade superficial aumentou nos demais grupos (A= 0,073mm, P-60= 0,095mm, Si= 0,158mm e Su= 0,470mm). SureFil apresentou a menor perda de massa e a maior variação de rugosidade superficial comparada às demais resinas testadas. Não houve correlação entre perda de massa e rugosidade superficial. As análises realizadas em microscopia eletrônica de varredura apresentaram-se coerentes com os resultados quantitativos obtidos. De maneira geral, as resinas compostas "condensáveis" apresentaram comportamento semelhante entre si e em relação à resina microhíbrida Z100. / "Condensable" composites resins are a category of posterior materials especially developed as an aesthetic alternative to amalgam. The aim of this research was to compare these materials by an "in vitro" abrasion test simulating toothbrushing. Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) and Filtek P-60 (P-60) were compared to two control groups, microfilleD Silux Plus (SP) and microhybrid Z100 (Z). Twelve samples of each material were prepared with 5mm in diameter and 3mm thick. The abrasion test was applied up to 100.000 cicles by an appropriate machine with soft bristles tips containing dentifrice solution and deionized water. The weight loss was detected by the differences between the initial (before toothbrushing) and the final weight (after toothbrushing) using a Sartorius analytical scale. The evaluation of surface roughness was observed by the difference between initial and final means after 5 readings in a Hommel Tester T1000 testing machine. The specimens were also analysed by SEM. The obtained results (ANOVA and Tukey) showed significant differences of weight and surface roughness between the tested materials. SureFil and Alert exhibited lower loss of weight (Su-0.38%; A-0.52%), Solitaire, Prodigy Condensable, and Silux Plus presented greatest wear(So-1.51%; PC-1.55%, SP-1.70%) while Z100 and Filtek P-60 showed intermediate loss ( Z-1.16%; P-60-1.31%). Differently to the others groups, Prodigy Condensable, Solitaire and Z-100 showed a decrease in surface roughness compared to the initial condition (-0.012mm,-0.047mm and -0.065mm respectively) which increased in the remainder groups (A) 0.073mm, P-60) 0.095mm, Si) 0.158mm and Su) 0.470mm). SureFil presented the lowest weight loss and the highest surface roughness variation comparing to the other tested resins. There was no correlation between wear and surface roughness. The SEM results were in accordance to those obtained by the Hommel Tester T1000 testing machine. "condensable" composites resins showed the same behavior compared to the microhybrid Z100 control resin.
|
154 |
Influência da aplicação de selantes de superfície na rugosidade de resinas compostas / Surface sealant application influence on the resin composite roughness.Flávia Pardo Salata Nahsan 27 March 2009 (has links)
Este estudo avaliou, in vitro, a influência da aplicação de quatro selantes de superfície na rugosidade de duas resinas compostas. Cinqüenta espécimes foram confeccionados e divididos em 10 grupos com 5 espécimes cada, em função da combinação entre resina composta e selante de superfície, sendo: G1. Controle Concept; G2. Concept + Fortify; G3. Concept + Biscover; G4. Concept + Lasting Touch; G5. Concept + Fill Glaze; G6. Controle Esthet X; G7. Esthet X + Fortify; G8. Esthet X + Biscover; G9. Esthet X + Lasting Touch; G10. Esthet X + Fill Glaze. Os espécimes foram confeccionados com uma matriz específica, em quatro incrementos, com dimensões internas de 15mmX4mmX5mm, sendo sua polimerização realizada com o aparelho de lâmpada halógena Curing Light 2500 (500mW/cm2) por 20s cada incremento. Em seguida, foram armazenados em água destilada à 37ºC e umidade absoluta de 100% por 24 horas. Após este período, os espécimes foram adaptados em uma Politriz Metalográfica e planificados com lixas de granulometria 320, 600 e a rugosidade inicial foi aferida. Para a mensuração da rugosidade, utilizou-se o rugosímetro Hommel Tester T1000 basic. Numa segunda fase, aplicaram-se os selantes de superfície, conforme recomendações do fabricante, e uma nova aferição da rugosidade superficial foi realizada. Para o teste de abrasão, os espécimes foram submetidos a 100.000 ciclos de escovação, seguido de nova mensuração da rugosidade. Em adição à rugosidade e com o objetivo de avaliar qualitativamente a superfície de alguns espécimes, a leitura em Microscopia Eletrônica de Varredura foi empregada. Os resultados foram submetidos aos testes ANOVA a 3 critérios e Tukey para comparações individuais entre os diferentes grupos (p<0,05). A aplicação do selante de superfície diminuiu a rugosidade superficial das resinas compostas testadas (G2=0,0727, G3=0,0147, G4=0,0307, G5=0,0253, G6=0,0960, G7=0,0173, G8=0,0333, G9=0,0480). A abrasão simulada aumentou a rugosidade superficial para todos os grupos, com exceção do Fortify (G2=0,0740, G7=0,0673) e Biscover (G7=0,0440), sendo os maiores valores apresentados pelo Lasting Touch (G4= 0,1253, G9=0,0980), seguido do Fill Glaze (G5=0,0933, G10= 0,0847). / This in vitro study evaluated the influence of the application of four surface sealers on the surface roughness of composite resins. Fifty specimens were divided into ten groups according to different patterns of composite resin and surface sealers, as follows: G1. Control with Concept resin; G2. Concept + Fortify; G3. Concept + Biscover; G4. Concept + Lasting Touch; G5. Concept + Fill Glaze; G6. Control with Esthet X; G7. Esthet X + Fortify; G8. Esthet X + Biscover; G9. Esthet X + Lasting Touch; G10. Esthet X + Fill Glaze. Specimens were made in four increments using a stainless steel matrix of 15x5x4mm and resin increments were polymerized with halogen lamp Curing Light 2500 (500mW/cm2) for 20 seconds each. After complete polymerization, specimens were stored in 100% humidity in distilled water at 37ºC for 24 hours. Following storage, specimens were polished using ascending grades (320, 600) of abrasive SiC paper under running water and the initial roughness was measured with a perfilometer Hommel Tester T100 basic (Hommelwerke GmbH ref. # 240851 - Schwenningem - Germany). Surface sealers were applied following the manufacturer\'s instructions and a new measurement of roughness was made. For the abrasive resistance test, specimens were submitted to 100.000 cycles of abrasive dentifrice brushing followed by surface roughness.. Qualitative analisys was made by using MEV. Results were submitted to Three-way ANOVA (p<0,05) and Tuckey\'s test to individual comparisons between different groups. Surface sealant application provided smoother surfaces for of composite resins tested (G2=0.0727, G3=0.0147, G4=0.0307, G5=0.0253, G6=0.0960, G7=0.0173, G8=0.0333, G9=0.0480). The abrasion test increased the surface roughness for all tested groups, except Fortify (G2=0,0740, G7=0,0673) and Biscover (G7=0,0440). Lasting Touch presented rougher surfaces (G4= 0,1253, G9=0,0980), followed by Fill Glaze (G5=0,0933, G10= 0,0847).
|
155 |
Tratamento superficial dos agregados reciclados de RCD com hidrofugantes. / Surface treatment of CDW recycled aggregates with water-repellents.Winnie Franco Santos 04 April 2016 (has links)
A proposta busca reduzir a absorção de água dos agregados reciclados de Resíduos de Construção e Demolição (RCD), através do tratamento de sua superfície com hidrofugante, de maneira que estes não aumentem o consumo de água tampouco reduzam a resistência mecânica. Os agregados reciclados de RCD foram caracterizados quanto à granulometria, morfologia, porosidade, ângulo de contato aparente, absorção de água, análise de imagem e rugosidade superficial. Em seguida, os mesmos foram tratados superficialmente com dois tipos de hidrofugante: solução de silano e parafina. Todos os tratamentos permitiram reduzir a absorção de água dos agregados reciclados de RCD. O tratamento por imersão foi aquele que permitiu obter os melhores resultados e a menor variabilidade entre as técnicas. Os tratamentos hidrofugam a superfície, apesar da parafina apresentar maior molhabilidade. O tratamento com parafina apresentou, em termos de absorção de água, resultados inferiores e menos variáveis que o silano. Os parâmetros de rugosidade constataram que, ambos os materiais perdem seu perfil topográfico original quando tratados com parafina. Os diferentes agregados reciclados com cada hidrofugante foram aplicados em materiais cimentícios analisados no estado fresco e no estado endurecido. Os tratamentos reduziram a absorção e o consumo de água de mistura, porém afetaram negativamente as propriedades mecânicas, devido nova interface gerada (no caso específica de parafina) e falta de molhabilidade nas superfícies. / The proposal aims to reduce the water absorption of the Construction and Demolition Waste (CDW) recycled aggregates through hydrophobic surface treatment, so that these do not increase the concretes water consumption (nor reduce de mechanical strength). The CDW recycled aggregates were characterized regarding granulometry, morphology, porosity, apparent contact angle, water absorption, image analysis and surface roughness. Then they had their surface treated with two types of water-repellent: silane solution and paraffin. All treatments have reduced water absorption of the CDW recycled aggregate. Immersion treatment was the one that allowed the best results and the lowest variability between techniques. The treatments repel water on surface, despite the paraffin presenting better wettability. Paraffin treatment showed, in terms of water absorption, lower and less variable results than silane did. Roughness parameters found that both materials lose their topographic profile when treating with paraffin. The different recycled aggregates with each repellent were applied in cementitious materials analyzed in fresh and hardened state. The treatments reduced absorption and mixing consumption of water in the mixing, but adversely affect mechanical properties due to the new interface created (paraffin wax in special) and the lack of wettability on surfaces.
|
156 |
Metodologia para avaliação da capabilidade de controle de superfícies técnicas usinadas em torno de ultraprecisão / Methodology to assess the capability of the control technical surfaces in ultraprecision turning manufacturingRosana Camargo 21 November 2005 (has links)
A nanotecnologia não é mais um sonho, já faz parte da nossa realidade, do nosso dia a dia. É considerada, por muitos, a quinta Revolução Industrial, uma revolução tecnológica de grande abrangência, que poderá causar impactos talvez sem precedentes na história. A soma anual dos investimentos nesta nova tecnologia é de bilhões de dólares. Devido às inovações oriundas da nanotecnologia, os processos da manufatura e a medição de ultra-precisão vêm se desenvolvendo a cada dia. A nanotecnologia fez da usinagem de ultraprecisão com ferramenta de diamante uma grande aplicação na produção de itens de alto volume, tais como: disco de memória de computadores, lentes de contato, moldes de dentes, cilindros para impressão, espelhos metálicos. A alta integridade da superfície é requerida em todos os itens obtidos por este processo. Em conseqüência, é necessário um método de medição que seja o mais exato possível, isto é, que chegue a resultados o mais próximo possível do valor verdadeiro. Mas o que significa exatidão para uma análise ideal da superfície, uma vez que não existe referência para isso? Superfícies têm sido avaliadas por meio da medição da rugosidade, a qual consiste na determinação de um valor médio, de vários setores, dentro de valores limites preestabelecidos. A metrologia, através de seus métodos e princípios, é um importante instrumento para validar modelos e teorias. O conceito que \"uma vez testado, passa a ser aceito em qualquer lugar\". Daí a crescente necessidade de resultados de medições confiáveis que possam ser validados em qualquer lugar e a qualquer tempo. Assim, um caminho a ser seguido é o de se entenderem profundamente todos os métodos e princípios envolvidos nas operações de medição de rugosidade. E para que um método seja metrologicamente válido (ou aceitável), faz-se necessário realizarem-se comparações de diversas medições, de um mesmo mensurando, utilizando métodos diversos. Havendo discrepância nos resultados, é uma evidência de que as premissas e hipóteses levaram a acreditar que a teoria ou modelo adotado deve ser reavaliado. Este trabalho selecionou os três métodos mais utilizados na caracterização da integridade de superfícies técnicas obtida em torneamento de ultraprecisão com diamante, e descreveu uma metodologia para a avaliação da capabilidade do processo de controle de superfícies técnicas usinadas em torno de ultraprecisão. / Nanotechnology is no longer a dream. It is part of the real world. It is considered by many people as the fifth Industrial Revolution, a technological revolution of great impact in history. The world annual investment in this technology reaches billions of dollars. Due to innovations related to nanotechnology, ultraprecision manufacturing processes and metrology is developing steeply. Nanotechnology made single point diamond turning an important mass production process of, for instance, computer hard discs, contact lenses, moulds, printer cylinders, metallic mirrors, etc. High grade surface integrity is required of items produced by this process. As a consequence, it is necessary to use a measurement method which is most accurate as possible, i.e., resulting in a value as close as possible to the true. But what does true mean if there is no reference for that? Surfaces have been assessed by roughness measurements which determines a mean value of several sectors within pre-determined limits. Metrology, with its methods and principles, is an important instrument to validate models and theories. The concept, once tested, becomes accepted everywhere. Therefore the increasing necessity of reliable measurement results which may be validated anywhere and any time. Thus, it is essential a deep understanding of all methods and principles involved in roughness metrology operations. For a method to be metrologically accepted, it is necessary that it is compared with different methods. In the event of existing discrepancies, the premisses and hypotheses which fundamented the theory or model should be reassessed. Three of the most used methods have been selected to characterize the surface integrity of technical surfaces generated by diamond turning. A methodology to assess the capability of the process of control of those surfaces is proposed.
|
157 |
Análise da rugosidade superficial de diferentes marcas comerciais de resina acrílica para coroas provisórias / Surface roughness analysis of acrylic resin for provisional crowns under different commercial brandsCintia Lumi Nishida 30 June 2010 (has links)
As coroas provisórias apresentam algumas características que podem comprometer a estética e facilitar aderência de microorganismos e formação de placa. Estudos prévios demonstraram que a forma de processamento influi na rugosidade e porosidade de uma marca comercial de resina acrílica comumente utilizada para a confecção de provisórias. Como diferentes marcas comerciais apresentam diferenças de qualidade, o presente estudo teve como objetivo principal avaliar a rugosidade superficial de quatro marcas comerciais de resina acrílica utilizadas na confecção de coroas provisórias (Dencor, Vipi, Duralay e Alike) de acordo com quatro técnicas de manipulação, diretas e indiretas. Os processamentos avaliados foram: GRUPO I autopolimerização sob pressão em matriz de silicona; GRUPO II - autopolimerização térmica em mufla; GRUPO III autopolimerização utilizando a técnica do pincel; GRUPO IV autopolimerização pela mistura em pote dappen. Para cada tipo de processamento foram confeccionados 12 corpos-deprova de cada material, totalizando 48 corpos-de-prova para cada grupo e 192 espécimes ao total. Logo após a confecção dos espécimes foi realizado o teste de rugosidade de superfície (Ra) através de um rugosímetro/perfilômetro. Posteriormente, a superfície dos mesmos foi uniformizada e polida com a utilização de politriz, realizando-se novamente os mesmos testes de rugosidade. Antes do acabamento e polimento de superfície, os resultados encontrados apontaram a maior rugosidade para resina Vipi (4,074 ± 0,541) e técnica da mistura em dappen gupo IV (3,538 ± 0,509), enquanto que a menor rugosidade foi encontrada para resina Alike (2,671 ± 0,512) e técnica da prensagem em mufla grupo II (2,733 ± 0,470). Após acabamento e polimento, a maior rugosidade foi encontrada para resina Vipi (0,207 ± 0,032) e técnica da pressão grupo I (0,172 ± 0,037), enquanto que a menor rugosidade para resina Alike (0,113 ± 0,036) e técnica da prensagem em mufla grupo II (0,138 ± 0,027). Com os resultados obtidos, foi possível concluir que a melhor combinação para confecção de coroas provisórias em resina acrílica foi a técnica da prensagem em mufla associada à resina Alike. / Provisional crowns have some features that may compromise aesthetics and favors adherence of microorganisms and dental plaque formation. Previous studies have shown that processing may influence roughness and porosity of acrylic resins commonly used make provisional crowns. Because the several commercial resins available present differences in their quality the aim of this study was to evaluate the surface roughness of four commercial brands of acrylic resins (Dencor, Vipi, Duralay and Alike) according to four manipulation techniques (two direct and two indirect): GROUP I - autopolimerization under pressure in a silicone matrix; GROUP II autppolimerization in flask; GROUP III - autopolimerization using the bead brush technique; GROUP IV - autopolimerization after mixing in dappen dish. For each type of processing 12 specimens were made of each material, being 48 specimens for each group and 192 specimens in total. After specimens preparation, surface roughness tests (Ra) was performed using a rugosimeter / profilometer. Posteriorly, all surfaces were polished for standardization and same roughness tests were performed again. Before finishing and polishing, the results pointed out that Vipi resin presented the highest roughness (4.074 ± 0.541). Mixing the resin in dappen dish group IV (3.538 ± 0.509) also presented the highest roughness values regarding the technique. The lowest roughness values were found with Alike resin (2.671 ± 0.512) and flask technique group II (2.733 ± 0.470). After finishing and polishing techniques, the highest roughness was found with Vipi resin (0.207 ± 0.032) and the autopolimetization under pressure in silicone matrix technique - group I (0.172 ± 0.037). The lowest roughness values were found with Alike resin (0.113 ± 0.036) and flask technique group II (0.138 ± 0.027). With these results, it was possible to conclude that the best combination for making provisional crowns was the flask technique associated with Alike resin.
|
158 |
Alteração de cor e rugosidade superficial de resina composta clareada após envelhecimento em função do tempo / Color change and surface roughness of composite resin cleared after accelerated artificial aging as a function of timeDaniela de Biagi Freitas 30 July 2010 (has links)
O presente trabalho teve como objetivo analisar “in vitro” a alteração de cor e a rugosidade superficial de uma resina composta (Charisma®) submetidas a tratamento clareador com agente clareador Lase Peroxide Sensy® (CC) e grupo controle sem tratamento clareador (SCL), após envelhecimento (EAA) em função do tempo, realizando-se avaliação superficial complementar por meio de Microscopia Eletrônica de Varredura (MEV) e EDX. Os corpos-de-prova (n=15) foram confeccionados com o auxílio de uma matriz de Teflon nas dimensões de 11x2,0mm, polidos com discos Soft Lex®, na seqüência de abrasividade decrescente e armazenados em saliva artificial a 37ºC (±1ºC), até os momentos de serem submetidos aos tratamentos propostos e à realização das leituras de alteração de cor e rugosidade superficial, nos tempos: 24 horas após a confecção (T0), após envelhecimento artificial acelerado (T1), 24 horas após clareamento (T2), 7dias (T3) e 1 mês após clareamento (T4). As leituras de alteração de cor foram obtidas com o auxílio do aparelho Espectrofotômetro (PCB6807BYK GARDNER) e para as leituras de rugosidade superfícial foi utilizado o Rugosímetro Mitutoyo SJ201P. Os dados foram submetidos à Análise de Variância ANOVA (p≤0,05). Os resultados obtidos foram: a) o fator Tempo teve efeito estatisticamente significante sobre as variáveis ΔE* (T1=T2=T3; T1=T4), L* (T0<T1=T2=T3=T4), a* (T0>T1=T2; T1=T3=T4; T4>T2), b* (T0>T1=T2=T3; T4=T3=T1; T2<T4) e rugosidade superficial (μm) (T0<T1,T2,T3,T4; T1=T2; T1<T3=T4; T2=T3=T4; b) para o fator tratamento com relação a ΔE* e fator L*(CC>SCL), para os fatores a* e b*(CC<SC), c) a interação Tratamento x Tempo não apresentou diferença estatisticamente significante para as variáveis ΔE*, L*, a*, b* e rugosidade superficial, d) as superfícies após EAA apresentaram alterações d) não houve mudanças no EDX antes e após os tratamentos. Conclui-se que a resina Charisma®, apresentou alteração de cor (ΔE*>3,3) e uma estabilidade na rugosidade superficial a partir de T2. / The current study in vitro evaluated the color change and surface roughness of the composite resin Charisma® cleared with Lase Peroxide Sensy® (CCL) and control without bleaching (SCL) after accelerated artificial aging (EAA) as a function of time, performing additional surface evaluation by scanning electron microscopy (MEV) and EDX. To obtain the color change and surface roughness a Spectrophotometer (PCB 6807 BYK GARDNER) and rugosimeter (Mitutoyo SJ- 201P) were employed respectively. Measurements were carried out at five times: 24 hours after preparation (T0), after artificial accelerated aging (T1), 24 hours after bleaching (T2), 7days (T3) and 1 month after bleaching (T4). The specimens (n=15) were prepared with aid of a Teflon (10-mmin diameter and 2mm thick). The specimens were polished with discs Soft Lex®, following abrasiveness decreased, being stored in artificial saliva at 37ºC (±1ºC) until the time of undergoing the proposed treatments and the measurements. The data obtained were submitted to ANOVA parametric test (p ≤ 0.05). The results were: a) time factor had a statistically significant effect on the variables ΔE* (T1 = T2 = T3, T1 = T4), L*(T0 <T1 = T2 = T3 = T4), a* (T0 > T1 = T2; T1=T3 =T4, T4>T2), b* (T0> T1=T2=T3, T4=T3=T1; T2<T4) and roughness(μm) (T0<T1,T2, T3,T4; T1 = T2; T1<T3=T4; T2=T3=T4), b) for treatment factor ΔE* and L* (CC> SCL) for the factors a*and b* (CC <SC), c) Treatment x Time interaction showed no statistically significant difference for the variables ΔE*, L*, a*, b* and surface roughness, d) after EAA the surfaces change d) before and after EAA dont have changes. It is concluded that the resin Charisma®, presented color change (ΔE *> 3.3) and surface roughness stability from T2.
|
159 |
Usos do território e rugosidades: fundamentos socioespaciais do patrimônio histórico do estado do Ceará / Uses of the territory and roughnesses: sociospatial foundations of the historical heritage of the Ceará StateMaria do Carmo Alves 09 February 2017 (has links)
Esta pesquisa buscou retomar o conceito geográfico de rugosidade proposto por Milton Santos, de modo a torná-lo coerente com as dinâmicas desta contemporaneidade, para se compreender a partir da análise do uso do território cearense, como as rugosidades do espaço geográfico exibem os objetos passíveis de preservação, haja vista ampliarem o conhecimento e significado de memória e patrimônio, usualmente propostos pelos historiadores, arquitetos e urbanistas. A tese tem como objeto de estudo os sítios urbanos das cidades de Sobral, Viçosa do Ceará, Aracati e Icó, tombados como Patrimônios Históricos. Fez-se necessário conhecer a totalidade do território e considerar a relação entre três elementos indispensáveis que são os instrumentais teórico, empírico e técnico, e sua indissociabilidade. Desse modo, chegou-se a uma interpretação da essência do processo socioespacial, visto como remanescente, perpétuo e dinâmico, resultado concreto e ativo das relações entre sujeitos e objetos, as rugosidades fundamentam as ações das práticas políticas e sociais. Espera-se que esta pesquisa possa proporcionar um debate com outras disciplinas, especialmente aquelas que dialogam com os estudos sobre patrimônio, memória e preservação, a partir das concepções apresentadas para compreensão da rugosidade como fundamento para entender o uso do território no tempo presente. / This research aim at retaking the geographic concept of roughness proposed by Milton Santos, in order to make it coherent with the contemporaneity dynamics, with the purpose of understanding, from the analysis of the territory use from Ceará State, the way how the roughnesses of the geographic space exhibit the objects susceptible of preservation, once they expand the knowledge and meaning of memory and heritage, usually proposed by historians, architects and urban planners. The thesis aims at studying the urban sites of the following cities: Sobral, Viçosa do Ceará, Aracati and Icó, inscribed on the Historical Heritage List. It was necessary to know the totality of the territory and to consider the relation between three indispensable elements that are the theoretical, empirical and technical tools, and their inseparability. In this way, an interpretation of the essence of the socio-spatial process, seen as remnant, perpetual and dynamic, concrete and active result of the relations between subjects and objects, the roughnesses underlie the actions of the political and social practices. It is expected that that this research may provide a debate with other disciplines, especially those that dialogue with the studies on heritage, memory and preservation, from the conceptions presented in order to understand the roughness as a basis for comprehending the use of the territory in the present time.
|
160 |
Influência das características petrográficas de granitos no processo industrial de desdobramento de blocos / Influence of petrographic characteristics of granites on the industrial process of blocks sawingRogério Pinto Ribeiro 19 December 2005 (has links)
O desdobramento de blocos de granitos, em teares multilâminas, é uma das mais complexas operações da indústria da pedra. A qualidade das superfícies das chapas obtidas no processo de serragem (rugosidade) determina o tempo e os insumos gastos nas operações posteriores de polimento, implicando diretamente no custo final. Embora o Brasil seja um dos maiores produtores mundiais de granitos ornamentais (quatro milhões de 'M POT.2'/mês de placas), surpreendentemente, não se têm na literatura científica trabalhos que dão o devido destaque às propriedades intrínsecas dos granitos no processo de serragem. A presente pesquisa tem como objetivo principal correlacionar parâmetros petrográficos com as características físicas e mecânicas de granitos, dando ênfase ao estudo da influência da mineralogia e da anisotropia textural/estrutural, com vistas à melhor orientação desta etapa industrial. Foram escolhidos tipos de granito consagrados comercialmente e acompanhados os desdobramentos de blocos para medidas diretas da rugosidade das superfícies serradas com o auxílio de um equipamento especialmente construído para esta finalidade. Os resultados mostraram que os aspectos texturais (granulação, arranjo, imbricação, grau de microfissuramento) e de alteração dos minerais são os responsáveis pelas diferenças na rugosidade das chapas e na velocidade de processamento / The sawing of granites blocks using multiblade gangsaws is one of the most complex operations in the stone processing industry. The slab surface quality (roughness) obtained after the sawing process determines the time and the inputs required in subsequent polishing operations and thus has a direct implication on the final product cost. Although Brazil is one of the largest world producers of ornamental granites (four million 'M POT.2'/month of slabs), it is surprising to note that there are very little or no scientific literature works available that address major aspects of the intrinsic properties of granites and their role during the sawing process. The present research has the major objective of correlating petrographic parameters with physical and mechanical characteristics of granites with a major emphasis on the role played by mineralogy and textural/structural anisotropy focusing mainly on how to obtain the best orientation during this industrial stage. The samples used are the most widely used granite of high commercial value in Brazil. The sawing process was monitored and subsequent direct measures of the roughness of the sawed surfaces carried out using an equipment specially built for this purpose. The results obtained show that textural (granulation, arrangement, imbrication, degree of microcracking) and alteration aspects of the minerals are responsible for the observed differences in slab roughness and processing speed
|
Page generated in 0.0405 seconds