• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 162
  • 3
  • 1
  • 1
  • Tagged with
  • 169
  • 169
  • 87
  • 80
  • 78
  • 65
  • 63
  • 50
  • 39
  • 39
  • 36
  • 32
  • 28
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Regulador MPC de tensão e velocidade integrado para unidades geradoras hidrelétricas

Menarin, Henrique Augusto January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Automação e Sistemas, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:33:48Z (GMT). No. of bitstreams: 1 325188.pdf: 6857768 bytes, checksum: 028cd5e4880d01d901291738cd104bee (MD5) Previous issue date: 2013 / Um conjunto razoável de objetivos de controle está associado à geração de energia hidrelétrica. Isto envolve o seguimento às referências de tensão, velocidade e potência, o amortecimento de oscilações eletromecânicas e o atendimento a restrições dos atuadores e de capabilidade do gerador. Adicionalmente, o processo é não linear e há acoplamento entre as variáveis controladas. Tradicionalmente, cada objetivo é tratado por malhas de controle específicas, cada qual com seus parâmetros de sintonia. Propõe-se o uso de um Controlador Preditivo baseado em Modelo (MPC) visando a atender todos os objetivos de controle de forma integrada. O controle proposto utiliza um modelo não linear simplificado da unidade geradora para o cálculo das predições. O controlador foi testado em vários cenários em comparação com o esquema de controle convencional. Obteve-se excelente desempenho de controle, sem o uso de malhas auxiliares. Também é discutida a influência dos parâmetros de sintonia sobre a resposta do processo. Verifica-se pelos resultados de simulações que a estratégia proposta é viável e permite melhorar o desempenho do sistema de controle, em comparação com controladores convencionais.<br> / Abstract : A wide set of control objectives is associated with the hydropower generation. This involves the tracking of terminal voltage, speed and active power references, the damping of electromechanical oscillations limitation of the generator operating point and actuators output. Additionally, the controlled process is non-linear and the variables are dynamically coupled. Each control objective is traditionally handled by dedicated control loops, each of them with isolated tuning parameters. The use of a Model Predictive Control (MPC) scheme is proposed as to consider all control objectives in an integrated calculation. The proposed controller uses a simplified non-linear model of the generating unit for calculating the predictions. The controller was tested in various cases, comparing its performance with the conventional control scheme. An excellent control performance was obtained, without need of auxiliar control loops. The influence of the tuning parameters on response characteristics is also discussed. The simulation results indicate that the strategy is viable and can improve the performance of the control system, compared to conventional controllers.
72

Implementação e análise de metodologias de identificação de oscilações eletromecânicas em um ambiente de desenvolvimento de aplicativos para o processamento de sincrofasores

Jeremias, Thiago January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T19:35:48Z (GMT). No. of bitstreams: 1 314918.pdf: 5341112 bytes, checksum: 20b11cc79ff2a0aef92b99a644caea46 (MD5) / Neste trabalho é descrito um ambiente de desenvolvimento de aplicativos para o processamento de dados fasoriais provenientes de SPMS, destinado à prototipação de metodologias e análise do desempenho do Sistema Interligado Nacional. O ambiente computacional, denominado DFAM, foi desenvolvido em Matlab® e possui funcionalidades como: análise em regime permanente, análise de ocorrências, qualidade de energia elétrica, identificação e detecção de eventos e estudos de oscilações eletromecânicas. Este ambiente tem sido amplamente utilizado no âmbito do Projeto MedFasee (LabPlan/UFSC), na realização de estudos do SIN e tem permitido o desenvolvimento de diversos outros trabalhos científicos. Fazem parte deste trabalho, a avaliação do desempenho de métodos de identificação de oscilações eletromecânicas, sendo estes os métodos de Prony, HTLS, Feixe de Matrizes, N4SID, Realização Balanceada Estocástica e Wiener-Hopf. Para uma adequada utilização destes métodos em sincrofasores são sugeridos ajustes nos parâmetros, tais como: ordem do modelo, tamanho da janela e dimensão das matrizes de dados. A demonstração deste ambiente computacional e avaliação das metodologias são feitas utilizando dados monitoradas pelo SPMS MedFasee BT de três grandes ocorrências no SIN. A primeira perturbação escolhida ocorreu em 10/02/2011 em que o SIN é separado em três subsistemas. Com esta ocorrência mostrou-se a efetividade das metodologias e dos ajustes de parâmetros aplicados em situações de ringdown, juntamente com a validação do cálculo das formas modais. O segundo evento ocorreu em 02/09/2011 envolvendo a UHE de Itaipu, com rejeição de carga de 5.100 MW desta usina. Com este evento, confirmam-se a eficiência dos métodos para ringdown e avaliam-se os métodos para processamento de dados ambientes. Os resultados encontrados foram satisfatórios, com destaque para o desempenho do método RBE que apresentou melhores resultados, com pouco esforço computacional. O terceiro evento analisado são de oscilações sustentadas que se mantiveram dos dias 05 a 09/05/2012 quando na região do Mato Grosso do Sul. Com este evento mostra-se a eficiência do método DFT aplicadas a dados ambientes, podendo ser estendida para monitoramento em tempo real.<br> / Abstract : This work describes an environment for developing applications for the processing of synchrophasors data, for the methodologies prototyping and performance analysis of the Brasilian Interconnected Power System. The computational environment called DFAM, was developed in Matlab ® and it has features such as: steady state analysis, events analysis, power quality analysis, detection and identification of events and eletromechanical oscillations analysis. The DFAM have been used to conduct studies of the Brazilian Interconected Power System (BIPS), and it have permited develop new methodologies uder the MedFasee Project (LabPlan/UFSC). Also as part of this work, has been evaluated the performance of methods for identification of electromechanical oscillations, which are the methods of Prony, HTLS, Matrix Pencil, N4SID, Balanced Stochastic Realization and Wiener-Hopf. For a proper use of these methods in synchrophasor are suggested adjustments to parameters such as: model order, the window size and dimension of the data matrix. The demonstration of this computing environment and the evaluation methodologies have made using data monitored by Low Voltage SPMS MedFasee of three major occurrences on BIPS. The first chosen disturbance occurred on Feb 02, 2010 wherein the BIPS was separated into three subsystems. With this occurrence was demonstrate the effectiveness of methods and parameter settings applied in rindgdown situations, along with the validation of the calculation of mode shapes. The second event occurred on Sept 02, 2011 involving the Itaipu Hydroelectric Power Plant, with load shedding of 5,100 MW from this plant. In this event was confirmed the efficiency of the methods for ringdown and was evaluated the methods for processing ambient data. The results were satisfactory, with emphasis on the performance of the RBE method that showed better results, with little computational effort. The third event analysed are permanent oscillations during the days May 05-09, 2012 in the Mato Grosso do Sul. With this event was showed the efficiency of the DFT method applied to ambient data, and was indicated that this method can be extended to monitoring in real time.
73

Identificação e classificação de pontos críticos de geração de potência reativa em estudos de máximo carregamento

Coelho, Viviane Berri January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2013-06-26T00:56:24Z (GMT). No. of bitstreams: 1 312058.pdf: 5183736 bytes, checksum: ce32c7cab0db88a68f2b0f9287979949 (MD5) / Esta dissertação apresenta uma metodologia para identificar e classificar os pontos de carregamento crítico em sistemas de potência. Duas estratégias são utilizadas como base desta metodologia. A primeira visa encontrar o ponto de máximo carregamento da rede elétrica e a correspondente solução do fluxo de potência. Esta abordagem assume que a curva PV é uma forma quadrática, com esta característica se tornando mais acentuada conforme o nível de carregamento do sistema se aproxima do ponto crítico. As principais motivações para o uso deste método são a rapidez da obtenção da solução e a robustez numérica do processo iterativo nas proximidades do ponto de máximo carregamento. A segunda estratégia utiliza um esquema preditor-corretor para identificar os pontos críticos de geração de potência reativa na rede elétrica, mediante o aumento do seu nível de carregamento. Assim, as barras que atingem o limite de geração de potência reativa são identificadas e os valores dos fatores de carregamento correspondentes são calculados simultaneamente. Na etapa de correção, as equações do fluxo de potência correspondentes a cada barra que atinge o limite de potência reativa incluem a representação da magnitude da tensão de referência e do balanço de potência reativa da referida barra PV, ajustadas respectivamente nos valores de referência e no limite atingido. A classificação dos pontos críticos é baseada em conceitos oriundos da Teoria da Bifurcação e em índices calculados com auxílio das relações de sensibilidade da geração de potência reativa com a magnitude das tensões nodais. Os resultados obtidos para dois sistemas testes, onde o primeiro é o sistema IEEE de 24 Barras, enquanto o segundo é um sistema equivalente da Região Sul do país, composto por 82 barras, ilustram as características principais dos métodos apresentados. / This dissertation presents a methodology to identify and to classify the critical loadability points in power systems. Two strategies are used as the basis of this methodology. The first aims to find the maximum loadability of the electrical network and its corresponding power flow solution. This approach assumes that the PV curve is a quadratic form, this feature becoming more accented as the loadability level is closer to the critical point. The main motivation to use this method are the fast way the critical solution is obtained and the numerical robustness of the iterative process around the maximum loadability point. The second strategy uses a predictor-corrector scheme to identify the loadability points related to critical levels of reactive power generation, as the loadability level increases. Thus, the buses whose limits of reactive power generation are reached are identified and the corresponding loadability factor is computed simultaneously. In corretor step, the equations of the power flow corresponding to the bus which has reached the reactive power generation limit include the modeling of both the reference voltage magnitude and the reactive power balance of the PV bus whose limit has been reached. The classification of these critical points is based on both some concepts from the Bifurcation Theory and indexes computed with the aid of sensitivity relationships between the reactive power generation and the bus voltage magnitude. The numerical results obtained with two test-systems, the IEEE 24 Buses and a reduced network equivalent to the power system of the Souther Region of Brazil, illustrate the main features of the methodology presented.
74

Estratégia em dois estágios utilizando rotações de givens em blocos para a inclusão de medidas fasoriais na estimação de estados em sistemas de potência

Bez, Daniel Martins January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro Tecnologico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2013 / Made available in DSpace on 2013-12-05T23:02:16Z (GMT). No. of bitstreams: 1 320585.pdf: 4182638 bytes, checksum: 02a21b067c23556c490f50767ef6c939 (MD5) Previous issue date: 2013 / Nesta dissertação é desenvolvida uma estratégia de estimação de estados em dois estágios para incorporar medidas fasoriais à estimação de estados em sistemas de potência. O primeiro estágio consiste de um estimador convencional, que processa apenas medidas oriundas do sistema SCADA. Nenhuma restrição é imposta ao seu algoritmo de solução. O segundo estágio é formado por um estimador que processa medidas fasoriais sincronizadas combinando-as com o resultado do primeiro estágio, de modo a obter, em uma etapa de pós processamento, a estimativa final combinada dos dois sistemas de medição.O segundo estágio é formulado em coordenadas retangulares, resultando em um modelo de medição linear. Como consequência, não é necessário recorrer a métodos iterativos e a solução é obtida de forma direta. A contrapartida da mudança do sistema de coordenadas é que as características estatísticas dos dados (e dos resultados do primeiro estágio) são alteradas. Além disso, as matrizes do problema passam a apresentar uma estrutura em blocos 2 x 2.Para solucionar o problema do segundo estágio foi desenvolvido um estimador de estados ortogonal baseado nas rotações de Givens em blocos. Este algoritmo, e a extensão matricial das rotações rápidas de Givens, são desenvolvimentos próprios deste trabalho que atendem às características do problema do segundo estágio sem abrir mão da robustez numérica.A metodologia proposta é avaliada através de casos de estudo conduzidos com os sistemas-teste de 14, 30 e 57 barras do IEEE. Resultados numéricos indicam melhoria na qualidade dos estados estimados quando todas as propriedades estatísticas e estruturais do problema do segundo estágio são consideradas através do método ortogonal baseados nas rotações de Givens em blocos <br> / Abstract: This thesis addresses a two-stage strategy to incorporate phasor measurements to power system state estimation. The ?rst stage consists of a conventional state estimator, which processes measurements acquired from SCADA systems only. No restriction is imposed upon its solution algorithm. The second stage processes phasor measurements combining them with the results of the ?rst stage in order to obtain, in a post-processing step, a ?nal state estimate based ondata from both measurement systems. The second stage formulation makes use of rectangular coordinates, resulting in a linear measurement model. Therefore, it is not necessary to rely on iterative methods and the solution is directly obtained. The price to be paid for this transformation is that the data statistical properties are modi?ed. Additionally, matrices of the measurement model of the second stage present a 2×2 block structure. An orthogonal state estimator based on a block form of Givens rotations has been developed in this thesis to solve the second stage. This algorithm, and the extended matrix form of fast Givens rotations, are developments of this thesis that meet the second stage requirements without com promising numerical robustness. Case studies are conducted on IEEE benchmark systems to evaluate the proposed methodology. Numerical results indicates quality improvements in the estimates when all statistical and structural properties of the second stage are considered through the proposed method.
75

Avaliação do impacto causado na proteção pela interligação de produtores independentes no sistema de distribuição de energia

Tavares, Temóstenes Nunes January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-21T03:59:14Z (GMT). No. of bitstreams: 1 210374.pdf: 4465741 bytes, checksum: f3d15d251ce94ce70c1b28884dcb682e (MD5) / O presente trabalho tem como objetivo apresentar uma análise acerca dos impactos, positivos e negativos, causados pela interconexão de produtores independentes de energia nos sistemas de distribuição. Esta avaliação aborda principalmente o comportamento dos sistemas de proteção empregados nas concessionárias de energia, visando detectar problemas e características inerentes que se apresentam nos sistemas quando os mesmos estão sob conexão dos novos agentes de geração. Outros temas que naturalmente se relacionam à interligação de novos produtores também foram abordados, como modificações nos níveis de curto circuito, redistribuição de fluxos de potência, elevações nos perfis de tensão e carregamento dos alimentadores dentre outros. Para tais avaliações foram utilizadas ferramentas computacionais para a realização de simulações. Uma ferramenta computacional para verificar a coordenação entre os dispositivos de proteção empregados nos sistemas de distribuição foi implementada. Dispondo de uma interface gráfica, o programa verifica a coordenação entre as proteções, traçando as curvas dos dispositivos num gráfico log-log, exibindo se existe seletividade entre os mesmos. Um sistema teste real foi utilizado nas simulações deste trabalho. Composto de um alimentador radial em nível de tensão 13,8 kV, com ramos de derivação, o sistema teste possui 45 nós. Foi estudado o caso de um produtor independente com geradores síncronos conectados ao longo de diferentes posições no alimentador, com seus respectivos perfis de geração. Os resultados obtidos indicaram que os dispositivos não direcionais perdem a seletividade com os novos fluxos de corrente, sendo necessário rever os esquemas de proteção adotados. Resultados benéficos como melhoria da regulação de tensão e suporte de reativos foram observados, porém possibilidades de ilhamentos, substituição de dispositivos, ônus financeiros contrapõem tais ganhos nas condições operativas do sistema.
76

Contribuição ao estudo da proteção de sistemas elétricos de potência

Mustafa, Thair Ibrahim Abdel Hamid January 2004 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-21T11:53:11Z (GMT). No. of bitstreams: 1 204072.pdf: 4243559 bytes, checksum: 1bc87ff64847aaadbf6352bb0e858613 (MD5)
77

Sistema especialista para auxílio à recomposição de subestações de transmissão na fase fluente

Sartor Filho, Alceu January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T01:07:27Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:32:38Z : No. of bitstreams: 1 184725.pdf: 5376536 bytes, checksum: 0cb41f57b3af585da915344f4e4c8348 (MD5) / Neste trabalho de mestrado são apresentadas as diversas etapas do desenvolvimento de um Sistema Especialista Baseado em Regras, proposto para auxiliar os operadores de subestações de sistemas de transmissão de energia elétrica na tarefa de recompor o sistema após contingências com desligamentos definitivos. As características do problema da recomposição de sistemas de potência (aspecto combinatorial, solução em vários estágios, diversos critérios a serem atendidos) dificultam a obtenção de soluções satisfatórias através de métodos analíticos. O Sistema Especialista desenvolvido visa dar apoio na etapa fluente da recomposição, quando os operadores realizam uma seqüência de manobras específica para cada situação, a partir de instruções de operação preparadas atavés de estudos prévios, sem necessidade de troca de informações com o centro de operação do sistema. O conhecimento armazenado na base de regras do sistema especialista foi adquirido a partir dos manuais de operação e de especialistas na área. O sistema possui integração com um Sistema de Supervisão e Controle, permitindo a obtenção direta de informações da rede elétrica, sem a entrada de dados pelo operador. Apesar do grande número de regras colocadas na base de conhecimento, o uso de uma estrutura modular facilita a etapa de verificação e validação da ferramenta, assim como futuras manutenções. Os benefícios diretos que podem ser obtidos com o uso deste sistema são a diminuição da duração das interrupções de fornecimento e da probabilidade de erros humanos durante a recomposição.
78

Estimação da seção em falta em sistemas elétricos de potência via redes neurais e sistemas especialistas realizada em nível de centro de controle

Cardoso Junior, Ghendy January 2003 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T11:43:30Z (GMT). No. of bitstreams: 0 / O presente trabalho aborda aspectos relativos à estimação da seção em falta em sistemas elétricos de potência (230 kV e 500 kV), realizada em nível de centro de controle, utilizando informações sobre a operação de dispositivos de proteção (relés e disjuntores). Tal metodologia deve ser empregada após a ocorrência de contingências com desligamentos definitivos, antes do processo de recomposição da rede. A ausência de uma formulação analítica para o problema propicia a utilização dos conceitos de técnicas não convencionais que incorporam o vasto campo da inteligência artificial. Dentre tais técnicas destacam-se as redes neurais artificiais e os sistemas especialistas. Neste trabalho as redes neurais foram utilizadas no tratamento das incertezas envolvidas em mensagens sobre atuação de relés e disjuntores, enquanto um sistema especialista é utilizado para complementar os resultados obtidos pelas redes neurais. De modo geral, o processo de diagnóstico segue três etapas principais: inicialmente são executadas as redes neurais a partir dos alarmes observados, sendo que um modelo de rede é empregado para cada componente elétrico; em seguida é identificada a área desligada, com base na operação de disjuntores de modo a determinar a topologia da rede desligada; por fim, é realizado o tratamento das informações de falta externa fornecidas pelos modelos neurais. Os resultados mostram que a metodologia proposta é aplicável em sistemas reais de grande porte, apresenta capacidade de generalização com relação a mensagens de operação de relés e disjuntores, as faltas múltiplas não necessitam de tratamento adicional, tal como os casos oriundos da atuação de proteções de retaguarda remota.
79

Uma metodologia para alocação de custos em um ambiente desregulamentado de energia elétrica

Medeiros, Andre Della Rocca January 2003 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T13:13:08Z (GMT). No. of bitstreams: 1 202546.pdf: 1004422 bytes, checksum: cb4166d99f920804cdd2277285427d21 (MD5) / A restruturação das empresas de energia elétrica que vem ocorrendo em diversos países, tem modificado as estratégias de gerenciamento e operação dos sistemas de potência. Uma das principais mudanças observadas é a transformação de um ambiente verticalizado e regulado num ambiente de contratos entre os diversos agentes integrantes. A implantação do novo modelo exige tanto a decomposição como a alocação dos custos relacionados ao suprimento de energia elétrica. Técnicas alocação de custos e estabelecimento de preços baseadas em custos marginais podem gerar excedentes de remuneração e apresentam volatilidade, pois refletem condições instantâneas. Por outro lado, a divisão do custo via critérios do tipo pro rata recupera exatamente o custo do serviço porém resulta em penalizações indiscriminadas. Neste trabalho, propõe-se o uso da metodologia de Aumann-Shapley para a alocação de custos, pois a mesma satisfaz as propriedades fundamentais requeridas para uma alocação justa. Mostra-se que esta metodologia pode ser aplicada de forma generalizada na alocação de custo de potências ativa e reativa, das perdas de potência ativa na rede de transmissão e do congestionamento. Sua aplicação permite recuperar o valor do serviço com precisão, fornecendo os fatores efetivos de participação de cada agente no custo total, independentemente das perdas e do congestionamento na rede.
80

Predição espacial temporal de sistemas elétricos de potência incluindo fontes renováveis emergentes / Spatio-temporal prediction os electric power systems including emergent renewable energy sources

Milanezi Junior, Jayme 12 March 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-15T18:54:01Z No. of bitstreams: 1 2014_JaymeMilaneziJunior.pdf: 6506741 bytes, checksum: 35af0d3d19c8dcffb7174539404b393b (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-16T17:36:58Z (GMT) No. of bitstreams: 1 2014_JaymeMilaneziJunior.pdf: 6506741 bytes, checksum: 35af0d3d19c8dcffb7174539404b393b (MD5) / Made available in DSpace on 2014-10-16T17:36:58Z (GMT). No. of bitstreams: 1 2014_JaymeMilaneziJunior.pdf: 6506741 bytes, checksum: 35af0d3d19c8dcffb7174539404b393b (MD5) / A atividade de planejamento de sistemas de potência inclui, como um de seus maiores desafios, a predicação do comportamento da carga. Com a finalidade de otimizar oinvestimento ante os dados de consumo, as empresas do setor elétrico lançam mão de várias técnicas de previsão da evolução da demanda que devem atender. No presente trabalho, o tema da predição espacial e temporal da carga é enfrentado, estudando e incorporando, simultaneamente, a tendência hoje já observada de inclusão de fonte sem microgeração distribuída. Três fontes renováveis e emergentes de geração foram consideradas como geradoras de energia pelos consumidores: enguias elétricas, painéis fotovoltaicos para aproveitamento da luz solar e de interiores, e antenas para reciclagemda energia existente nas ondas eletromagnéticas de radiodifusão. Quatro métodos preditivos foram empregados para prever o comportamento da carga: modelo Auto-Regressivo (AR), Auto-Regressivo com Variável eXógena (ARX), Auto-Regressivo deMédia Móvel com Variável eXógena (ARMAX) e Redes Neurais Artificiais (ANN). Os dados de consumo foram as máximas demandas semanais registradas em 8 Subestações da cidade de Leipzig (Saxônia, Alemanha), durante os anos de 2001, 2002, 2003 e 2004.O dado exôgeno considerado foi a temperatura, em valores diretos e logarítmicos. Das 209 semanas existentes entre 2001 e 2004, as 200 primeiras destinaram-se ao ajuste dos coeficientes nos modelos AR e ao treinamento da rede neural; as 9 semanas restantesforam destinadas à comparação de resultados. A aplicação das técnicas deu-se, assim,em dois estágios: no primeiro, os dados reais da rede de Leipzig foram considerados, eno segundo estágio trabalhou-se com novos valores de demandas máximas, originadaspela inserção de valores hipotéticos de energia recebida das três fontes citadas. Emambos os estágios, o modelo ARMAX foi o de melhor precisão na previsão de dados.O sistema de redes neurais demonstrou ser um sistema sub-ótimo de previsão. ______________________________________________________________________________ ABSTRACT / Power systems planning activities include load behavior prediction as one of its mostchallenging tasks. In order to optmize investments related to consumption data, utilitiesfrom the Electrical Sector resort to several forecasting techniques so that theycan predict the power demand which these utilities must support. Along the presentwork, issues related to the spatial and temporal predictions are faced, considering,simultaneously, the observed trend of microgeneration spread. Three emergent renewablesources were proposed to be taken on by consumers: electric eels, photovoltaicsolar panels for outdoor generation and indoor light energy harvesting, and antennasfor radio frequency energy recycling. Four predictive methods were employed in orderto forecast load evolution: Auto-Regressive (AR), Auto-Regressive with eXogeneousinputs (ARX), Auto-Regressive Moving Average with eXogeneous inputs (ARMAX)models and Artificial Neural Networks (ANN). Consumption data were the maximumweekly power demands registered over 8 Power Substations from the city of Leipzig(Saxony, Germany), during the years 2001, 2002, 2003 and 2004. The exogeneousvariable adopted was temperature, in realistic and in logarithmic values. During the209 weeks which are comprised between 2001 and 2004, the _rst 200 weeks served tocoe_cients adjustments, with regards to AR models, and the trainning of the neuralnetwork, in the case of ANN. The last 9 weeks were destinated for results comparison.Techniques were undertaken in two stages: _rstly, only realistic data from LeipzigSubstations were considered, and in the second stage, new values for maximum powerdemands were obtained by means of simulations upon the three emergent sources. Inboth stages, ARMAX model returned the _ttest results, whereas ANN characterizeditself as a sub-optimal prediction system.

Page generated in 0.0897 seconds