1

Réalisation d'une plateforme biopuce sans marquage basée sur la lithographie douce

Lalo, Helene 16 March 2009 (has links) (PDF)
L'amélioration des biopuces et de leurs lecteurs est un enjeu crucial dans l'industrie actuelle qui réclame des méthodes d'analyses moléculaires plus sensibles et moins onéreuses. Dans ce but, plusieurs points doivent être revus : sensibilité du lecteur, densité des puces, marquage en fluorescence des biomolécules. Nous avons mis en place et développé différentes techniques de dépôt de molécules basées sur la lithographie douce ainsi qu'une technique de détection d'interaction biologique par diffraction afin de créer une plateforme biopuce complète, sans marquage et à bas coût. A travers ce mémoire de thèse, la structuration de diverses molécules à l'échelle nanométrique sur un substrat sera étudiée : structuration de dendrimères, de polymères à empreintes moléculaires (MIP), d'ADN. Nous verrons des techniques pour structurer des couches à l'échelle nanométrique par lithographie douce, mais sans avoir recours préalablement à la lithographie électronique pour créer les moules. De même, nous étudierons le " macrotimbre " qui permet le dépôt de plusieurs molécules différentes en une seule étape (multiplexage) par lithographie douce. Une technique de détection par diffraction de la lumière sera développée afin de passer outre l'étape de marquage qui porte le risque d'endommager la molécule et donc de dénaturer ses fonctions. Ce travail se place dans le cadre d'un projet de développement industriel en partenariat avec la société INNOPSYS et dont l'objectif est de démocratiser l'analyse biopuce en une solution financièrement accessible aux hôpitaux et aux laboratoires d'analyses et non plus seulement aux seuls organismes de recherche.
2

Développements de méthodes de préparation d’échantillons pour l’analyse protéomique quantitative : application à la recherche de biomarqueurs de pathologies / Development of sample preparation methods for quantitative proteomics : application to diseases biomarkers research

Muller, Leslie 21 December 2017 (has links)
Les stratégies de protéomique quantitative sans marquage sont très attractives dans le domaine de la recherche de biomarqueurs de pathologies. Cependant, elles requièrent une pleine maîtrise du schéma analytique et de sa répétabilité. Plus particulièrement, la préparation d’échantillons nécessite d’être suffisamment répétable pour ne pas impacter la qualité et la fiabilité des résultats. Les objectifs de cette thèse étaient de développer et d’optimiser des méthodes analytiques pour la protéomique quantitative, en particulier pour l’étape de préparation d’échantillons. Ainsi, un protocole innovant, simple, rapide et permettant l’analyse quantitative sans marquage d’un grand nombre d’échantillons avec une haute répétabilité a été développé et optimisé : le « Tube-Gel ». Par ailleurs, des préparations d’échantillons adaptées à différentes matrices biologiques pour la recherche de biomarqueurs ont été élaborées. Les méthodes mises au point et leur application ont permis de proposer des candidats biomarqueurs pour plusieurs pathologies : le glioblastome, les lymphomes B diffus à grandes cellules, et les complications survenant sur les greffons rénaux. / Label-free quantitative proteomics strategies are very attractive for diseases biomarkers researches. These approaches require the full control and the repeatability of the analytical workflow. In particular, the sample preparation has to be repeatable enough to ensure the quality and reliability of the results. Objectives of this work were to optimize and develop analytical methods for quantitative proteomics, with a special focus on the sample preparation step. Thus, an innovative, easy and fast protocol allowing the analysis of high sample numbers with high repeatability was developed and further optimized: the “Tube-Gel” protocol. Besides,sample preparations adapted to a variety of biological matrices were developed for the search of biomarkers. The developed methods and their application allowed the identification of potential biomarkers for a variety of diseases: glioblastoma, diffuse large B-cell lymphomas and renal transplants failures.
3

Nouvelles technologies intégrées d'adressage et de détection des interactions moléculaires pour application de biopuces en diagnostic moléculaire in vitro / Novel integrated technologies of patterning and detection for the conception of microarrays dedicated to in vitro molecular diagnosis

Foncy, Julie 12 December 2013 (has links)
Le marché du diagnostic connait un essor considérable depuis l’avènement de labiologie moléculaire. Plus précis et souvent plus rapide, le diagnostic moléculaire in vitro(DIV) est de plus en plus utilisé dans les laboratoires d’analyses médicales. L’ensemble destests dédiés au marché du DIV répond à des contraintes socio-économiques très précisescomme : la fiabilité du résultat, le délai de réponse court, le faible coût et la facilitéd’utilisation. Les indicateurs socio-économiques montrent que la technologie des biopuces estun potentiel bon candidat pour répondre aux attentes du marché. En effet, cet outil permetl’analyse simultanée de plusieurs dizaines voire centaines de séquences nucléiques et doncl’identification d’autant d’organismes en une seule analyse. Cette technologie s’inscrit encomplément de la PCR en apportant l’avantage de l’analyse multiplexée à moyen débit. Deplus, elle permet de donner une réponse globale de la multiplicité des espèces présentes dansl’échantillon sans avoir besoin de passer par une étape de culture. Néanmoins, cettetechnologie n’est pas optimisée pour le marché du DIV. En effet, son usage est complexe, peurobuste et trop cher pour concurrencer les méthodes actuelles (microbiologie pasteurienne,PCR, Elisa, etc..). Dans le but de réduire le coût de fabrication des biopuces à ADN, il estdonc nécessaire de développer des méthodes alternatives. Dans un premier temps, l’objectif de cette thèse Cifre a été de mettre au point unprototype nouveau de dépôt de biomolécules basé sur la lithographie douce, permettant dedéposer les oligonucléotides sondes de façon multiplexée et selon des motifs micrométriques.Cette nouvelle technologie a été évaluée par rapport aux technologies de références. Puis,nous avons développé un procédé innovant de double fonctionnalisation de surface. Ceprocédé simple et rapide a pour avantages de fonctionnaliser la biopuce avec la chimie desurface et les sondes en une seule étape et d’augmenter les signaux d’hybridation. La secondepartie de la thèse a été de coupler cette nouvelle technologie à la détection des événementsd’hybridation sans marquage en utilisant la diffraction de la lumière. La principale différenceavec la méthode de détection par fluorescence repose sur l’adressage des sondes. En effet, ledépôt doit être réalisé sous forme de réseaux de lignes nanométriques diffractants de façon àce que l'interaction entre les molécules déposées et les cibles qui interagissent soit trèssensible. Cette seconde phase du projet a été très ambitieuse et innovante. La faisabilité decette méthode de détection, démontrée par des simulations théoriques, a fait l’objet d’untravail d’optimisation très important et les résultats obtenus montrent que cette technologiesans marquage est possible. / The diagnosis market increased since the advent of molecular biology. More precise and often faster, the in vitro molecular diagnosis (DIV) is more and more used in medical analyses laboratories. DNA chips technology seems to be a good candidate to answer the market expectations. Indeed, this tool allows making several hundreds of analyses simultaneously. Furthermore, it allows giving a global answer of all the present species in the sample without the need of a culture step. Nevertheless, this technology is not optimized for the market of the DIV. Indeed, its use is complex and too expensive in comparison with the current methods (Pasteur microbiology, PCR, Elisa, etc.). So it is necessary to develop an alternative method to reduce the manufacturing cost and simplify the use of DNA chips. First, the goal of this industrial PhD Cifre supported by the Dendris Company was to complete a new prototype of biomolecules deposition based on soft lithography, allowing multiplexing the deposition of oligonucleotides probes along micro and nanometric patterns.This new technology was compared with the reference technologies. Then, we developed an innovative process of surface co-functionalization. This simple and fast process permits to functionalize the DNA chips with both surface chemistry and probes in a single step and to increase the hybridization signals. The second part of this PhD thesis was to couple this new technology with label-free detection using light diffraction. The main difference with fluorescence-based detection was about probes patterning. Indeed, we needed to generate molecular gratings of nanometric lines to diffract efficiently light from a laser beam. We showed that the absolute diffraction intensity increase with the gratings thickness, which is directly correlated with, probes and targets interactions. The second phase of the project was very ambitious and innovative because we demonstrated the feasibility of this label-free detection. And now we can think that this technology will appear as an alternative method for the diagnosis
4

Biodétection optique sans marquage basée sur la diffraction de motifs moléculaires submicroniques

Cau, Jean Christophe 21 November 2008 (has links) (PDF)
La détection d'interactions biologiques est un des enjeux majeurs de différents domaines tels que le diagnostic médical ou le criblage de médicaments. L'objectif de ce travail est le développement d'une technique de biodétection sans marquage basée sur la diffraction d'un réseau de lignes submicroniques composées de biomolécules. Pour cela, nous développons un modèle optique permettant de simuler la réponse de biocapteurs diffractifs qui détermine les paramètres clefs adaptés à une détection optimale. Nous démontrons l'application de cette technologie à la détection de deux interactions biochimiques différentes, l'une représentant le domaine du diagnostic, l'autre celui du criblage pharmacologique. En se basant sur ces résultats, une corrélation avec le modèle développé est effectuée. Nous proposons aussi un procédé parallèle de dépôt par tamponnage moléculaire de différentes biomolécules en une seule étape, intégré dans le système de détection. Une réflexion sur le rôle et l'impact au niveau du citoyen de cette technologie, et plus généralement des nanotechnologies, est présentée.
5

Conception et implémentation d'un imageur CMOS de colonne actif pour capteurs basés sur SPR

Salazar Soto, Arnoldo 30 October 2013 (has links) (PDF)
Cette thèse présente la conception et la mise en œuvre d'un imageur CMOS pour être utilisé dans biocapteurs intégrés basés sur Résonance Plasmonique de Surface (SPR). Tout d'abord, les conditions optimales pour la résonance plasmon dans une interface compatible CMOS / post-CMOS sont obtenus par modélisation avec COMSOL. Deuxièmement, un imageur CMOS de Colonne Actif (CMOS-ACS) du 32x32 pixels est mis en œuvre sur une technologie CMOS 0,35 um. Dans une interface d'or-eau avec une excitation de prisme, on constate que pour les prismes avec des indices de réfraction de 1,55 et 1,46, le couplage optimal avec le plasmon est obtenu pour des films d'or d'une épaisseur de 50 et 45 nm, respectivement. Dans ces conditions, environ 99,19% et 99,99% de l'énergie de la lumière incidente est transférée à le surface plasmon pour les deux prismes respectivement, à condition que la lumière incidente, avec une longueur d'onde de 633 nm, arrive avec un angle d'incidence de 68,45° et 79,05° respectivement. Il est également obtenu qu'un changement de RIU 10-4 de l'indice de réfraction du milieu diélectrique, produit un changement de 0,01 ° dans l'angle de résonance de plasmons qui, dans un schéma de modulation d'intensité de lumière produit une variation de 0,08% dans la lumière réfléchie au photodétecteur. En ce qui concerne le imageur CMOS, une photodiode n-well/p-substrate est choisi comme l'élément de photodétection, en raison de sa faible capacité de jonction, ce qui conduit à un rendement élevé et le gain de conversion élevé comparativement à une photodiode n-diff/p-substrate. Des simulations sur ordinateur avec Cadence et Silvaco produit une capacité de jonction de 31 FF et 135 fF respectivement. Le pixel de l'imageur est basé sur une configuration à trois transistors (3T) et présente un facteur de remplissage de 61%. Le circuit de lecture utilise une technique de capteur de colonne actif (ACS) pour réduire le bruit à motif fixe (Fixed Pattern Noise ou FPN en anglais) liée au le Capteur à Pixels Actif (APS) traditionnelle. En outre, Non-Corrélés Echantillonnage Double (Non-Correlated Double Sampling ou NCDS en anglais) et Delta double échantillonnage (DDS) sont utilisés comme techniques de réduction du bruit. Un montage optique expérimental est utilisé pour caractériser les performances de l'imageur, et nous avons obtenu un gain en conversion de 7,3 uV/e-, une capacité de jonction de la photodiode de 22 fF, un bruit de lecture de 324,5 uV, ce qui équivaut à 45 électrons, et une gamme dynamique de 50,5 dB. Les avantages de l'ACS et NCDS-DDS sont observées dans le niveau faible de FPN du pixel et de la colonne, avec une valeur de 0,09% et 0,06% respectivement. Le travail présenté dans cette thèse est une première étape vers l'objectif de développer une plateforme entièrement intégrée SPR pour biocapteurs, incorporant source de lumière, l'interface SPR, canal microfluidique, les éléments d'optique et imageur CMOS.
6

Technical improvements for analysis of recalcitrant proteins by LC-MS : the myccorhiza responsive membrane proteome as a case study / Vers l'étude quantitative et fonctionnelle des protéomes membranaires des racines mis en jeu au cours de la symbiose mycorhizienne à arbuscules de Medicago truncatula par des approches de protéomique hors gel

Abdallah, Cosette 26 October 2012 (has links)
La symbiose mycorhizienne à arbuscules (SMA) est le résultat de l'interaction entre les racines de plus de 80% des familles de plantes terrestres et les champignons MA. Divers types de membranes jouent un rôle crucial dans la mise en place et le fonctionnement de la SMA chez l’hôte végétal. Si l’électrophorèse bidimensionnelle (2-DE) reste la méthode la plus couramment utilisée pour des analyses protéomiques quantitatives dans la SMA, elle résout difficilement les protéines membranaires en raison de leur hydrophobicité, leur précipitation au point isoélectrique (pI) et leur faible abondance comparativement aux protéines cytosoliques. Donc peu nombreuses sont les protéines membranaires identifiées comme étant régulées en réponse à la symbiose. Afin d’avoir accès à cette catégorie de protéines et contourner les défauts de la 2-DE, l’application de nouvelles méthodes permet de réaliser des analyses quantitatives avec marquage chimique (comme l’iTRAQ) ou non (label-free). Dans ce contexte, deux méthodes de protéomique quantitative, iTRAQ-OFFGEL-CL-SM/SM et « label-free » 1-DE-CL-SM/SM, sont adoptées dans ce travail visant à identifier et quantifier les variations d’accumulation des protéines microsomales de racines de Medicago truncatula inoculées par Rhizophagus irregularis, préalable indispensable à l’analyse de leur rôle fonctionnel dans la SMA. Un protocole d’extraction donnant accès à des fractions radiculaires enrichies en protéines microsomales nécessaires pour les analyses ultérieures est décrit dans cette étude. En plus de l’analyse quantitative du protéome membranaire en réponse à la SMA, une approche méthodologique a été mise en place afin d’étudier l’impact du marquage iTRAQ sur le pI des peptides. / Arbuscular mycorrhizas (AM) are widespread symbiotic associations between plant roots and AM fungi. Deep membrane alterations are the foremost morphological changes occurring in the host plant in response to AM symbiosis. Two-dimensional gel electrophoresis (2-DE) is the workhorse method in AM proteomics. Membrane proteins are under-represented in 2-DE because of their hydrophobicity, low abundance, and precipitation at their isoelectric point, thereby few are the identified membrane proteins involved in sustaining the AM symbiosis. Membrane proteomics is still challenging due to 2-DE related shortcomings, however latest trends and advancements in mass spectrometry (MS)-based quantitative proteomics offer enormous potential to monitor membrane protein change in abundance in large scale experiments. In the current work microsomal proteins of Medicago truncatula roots inoculated with Rhizophagus irregularis were, for the first time, scrutinised by state-of-the-art MS-based proteomic approaches iTRAQ-OFFGEL-LC-MS/MS and label-free 1-DE-LC-MS/MS. The applied workflows combine two novel proteomic procedures, label-based and -free, targeting an insight view on the membrane proteome changes in AM symbiosis. A subcellular fractionation method is herein described to access the total membrane-associated proteins with sufficient recovery and purity for their subsequent in-depth analysis. In addition to the biological gain by shedding the light on candidate AM-related membrane proteins, a methodological approach was carried out in the present work in order to elucidate the iTRAQ labelling impact on peptide isoelectric points.
7

Analyse quantitative d’images de phase obtenues par interféromètrie à décalage quadri-latéral. Applications en biologie / Quantitative phase images analysis obtained by quadri-wave lateral shearing interferometry. Applications to biology

Aknoun, Sherazade 04 December 2014 (has links)
Ces travaux de thèse, consacrés à l'étude et analyse quantitative d'images de phase obtenues par interférométrie à décalage quadri-latéral, ont pour but la caractérisation d'un point de vue métrologique d'un outil de mesure et de ses différentes applications. Cette technique d'interférométrie, développée initialement par la société Phasics pour les marchés de la métrologie optique et de la caractérisation de faisceaux laser essentiellement, peut aussi permettre d'obtenir la cartographie d'un champ électromagnétique complexe grâce à une mesure de front d'onde. En l'utilisant sur un microscope en condition d'imagerie, ont été obtenues des images de l'intensité et de la différence de chemin optique introduite par un échantillon semi-transparent, définissant ainsi une nouvelle technique de contraste de phase quantitatif. La première partie de cette thèse sera consacrée aux techniques en microscopie qui permettent une quantification. Nous verrons les enjeux de l'obtention de ce caractère quantitatif et ce qu'il signifie dans le cadre de différentes techniques utilisant la fluorescence. On étudiera la mesure dans le cadre d'une approximation dite "projective" réalisant certaines hypothèses. On verra quelles sont les grandeurs accessibles grâce à une mesure dans le cadre de cette approximation et quelles applications en biologie peuvent être développées concernant les éléments isotropes dans une première partie et les éléments anisotropes dans une seconde partie.Nous démontrerons la possible transposition de ces applications réalisées en deux dimensions en trois dimensions avec une résolution axiale suffisante permettant une reconstruction tomographique. / The aim of this thesis, dedicated to the study and quantitative analysis of phase images obtained thanks to quadri-wave lateral shearing interferometry, is to caracterize a metrological tool and its three proposed different applications.This work has been done in collaboration between Institut Fresnel (Marseille, France) and Phasics company (Palaiseau, France) and continues that of Pierre Bon who has been in charge the application this technique to microscopy. This interferometric technique, developped by Phasics, for optical metrology and lasers characterization, allows to record complex eletromagnetic field maps thanks to a wave front measurement. By using it in the microscope image plane, one can obtain inetnsity and optical path difference images of a semi-transparent biological sample. this technique is now considered as a new quantitative phase contrast technique.The first part of this manuscript will be a state of the art of quantitative microscopy techniques. The issues of quantification and its meanings in the framework of different fluorescent and phase based techniques will be discussed.A description of the technique that is used and its comparison with similar phase techniques will be done.The measurement, under the projective approximation, is studied leading to different variables. We show different applications concerning isotropic elements in a first part and anisotropic elements in the second one.We show how this measurement is trnasposed to the third dimensions allowing three dimensional imaging and complete reconstruction of refractive index maps of biological samples.
8

Micro électrochimie et optique couplées pour l'imagerie et l'étude de réactions chimiques de surface

Munteanu, Sorin 15 October 2012 (has links) (PDF)
L'objectif est de développer des méthodes permettant de suivre et de quantifier la réactivité chimique de surface à l'échelle micrométrique. Nous proposons une approche optique qui utilise une détection sans marquage basée sur un changement d'indice de réfraction. Le principe repose sur le couplage entre techniques d'imagerie, de microscopie optique et de micro-électrochimie pour étudier et cartographier en temps réel et in situ des processus (électro)chimiques interfaciaux. Les potentialités de ces techniques sont mises en évidence sur un système modèle : l'électrogreffage de films minces organiques sur des surfaces par réduction de sels de diazonium. La réactivité (bio)chimique est étudiée ex situ et in situ sur différentes surfaces d'or : des microélectrodes ou des macroélectrodes décorées par impression par microcontact ou par lithographie. La méthode est intéressante pour examiner la réactivité chimique de diverses molécules immobilisées vis-à-vis de radicaux électrogénérés. Ces microscopies opto-électrochimiques montrent que la microlithographie modifie la réactivité de surface et qu'elle doit donc être réalisée soigneusement quand on cherche à déterminer la réactivité de la surface. Finalement, ces travaux sont appliqués au développement d'une méthode analytique par microscopie électrochimique (SECM) pour détecter des mouvements mécaniques de microleviers suite à un changement de tension de surface.
9

Conception d'un imageur CMOS à colonne active pour un biocapteur optique SPR / Design and Implementation of a CMOS imager with active column for SPR-based sensors / Diseño e implementaciòn de un sensor de imagen CMOS de columna activa para biosensores basados en SPR

Salazar Soto, Arnoldo 30 October 2013 (has links)
Cette thèse présente la conception et la mise en œuvre d'un imageur CMOS pour être utilisé dans biocapteurs intégrés basés sur Résonance Plasmonique de Surface (SPR). Tout d'abord, les conditions optimales pour la résonance plasmon dans une interface compatible CMOS / post-CMOS sont obtenus par modélisation avec COMSOL. Deuxièmement, un imageur CMOS de Colonne Actif (CMOS-ACS) du 32x32 pixels est mis en œuvre sur une technologie CMOS 0,35 um. Dans une interface d'or-eau avec une excitation de prisme, on constate que pour les prismes avec des indices de réfraction de 1,55 et 1,46, le couplage optimal avec le plasmon est obtenu pour des films d'or d'une épaisseur de 50 et 45 nm, respectivement. Dans ces conditions, environ 99,19% et 99,99% de l'énergie de la lumière incidente est transférée à le surface plasmon pour les deux prismes respectivement, à condition que la lumière incidente, avec une longueur d'onde de 633 nm, arrive avec un angle d'incidence de 68,45° et 79,05° respectivement. Il est également obtenu qu'un changement de RIU 10-4 de l'indice de réfraction du milieu diélectrique, produit un changement de 0,01 ° dans l'angle de résonance de plasmons qui, dans un schéma de modulation d'intensité de lumière produit une variation de 0,08% dans la lumière réfléchie au photodétecteur. En ce qui concerne le imageur CMOS, une photodiode n-well/p-substrate est choisi comme l'élément de photodétection, en raison de sa faible capacité de jonction, ce qui conduit à un rendement élevé et le gain de conversion élevé comparativement à une photodiode n-diff/p-substrate. Des simulations sur ordinateur avec Cadence et Silvaco produit une capacité de jonction de 31 FF et 135 fF respectivement. Le pixel de l'imageur est basé sur une configuration à trois transistors (3T) et présente un facteur de remplissage de 61%. Le circuit de lecture utilise une technique de capteur de colonne actif (ACS) pour réduire le bruit à motif fixe (Fixed Pattern Noise ou FPN en anglais) liée au le Capteur à Pixels Actif (APS) traditionnelle. En outre, Non-Corrélés Echantillonnage Double (Non-Correlated Double Sampling ou NCDS en anglais) et Delta double échantillonnage (DDS) sont utilisés comme techniques de réduction du bruit. Un montage optique expérimental est utilisé pour caractériser les performances de l'imageur, et nous avons obtenu un gain en conversion de 7,3 uV/e-, une capacité de jonction de la photodiode de 22 fF, un bruit de lecture de 324,5 uV, ce qui équivaut à 45 électrons, et une gamme dynamique de 50,5 dB. Les avantages de l'ACS et NCDS-DDS sont observées dans le niveau faible de FPN du pixel et de la colonne, avec une valeur de 0,09% et 0,06% respectivement. Le travail présenté dans cette thèse est une première étape vers l'objectif de développer une plateforme entièrement intégrée SPR pour biocapteurs, incorporant source de lumière, l'interface SPR, canal microfluidique, les éléments d'optique et imageur CMOS. / This dissertation presents the design and implementation of a CMOS imager for use in integrated biosensors based on Surface Plasmon Resonance. First, the optimal conditions for plasmon resonance in a CMOS/Post-CMOS compatible interface are obtained by COMSOL modelling. Second, a 32x32-pixel CMOS-Active Column Sensor (CMOS-ACS) is implemented on 0.35 um CMOS technology. In a gold-water interface with prism excitation, it is found that for prisms showing refractive indexes of 1.55 and 1.46, optimal plasmon coupling is obtained for gold films with thicknesses of 50 and 45 nm respectively. Under these conditions, approximately 99.19% and 99.99% of the incident light's energy is transferred to the surface plasmon for both prism respectively, provided that the incident light, with a wavelength of 633 nm, arrives with incidence angles of 68.45° and 79.05° respectively. It is also obtained that a change of 10-4 RIU in the refractive index of the dielectric medium, produces a change of 0.01° in the plasmon resonance angle, which under a light intensity modulation scheme produces a change of 0.08% in the reflected light's energy reaching the photodetector. Concerning the CMOS imager, a n-well/p-substrate photodiode is selected as the photosensing element, due to its low junction capacitance, which results in high efficiency and high conversion gain compared to the n-diff/p-substrate photodiode. Computer simulations with Cadence and Silvaco produced a junction capacitance of 31 fF and 135 fF respectively. The imager's pixel is based on a three-transistor (3T) configuration and shows a fill factor of 61%. The readout circuitry employs an Active Column Sensor (ACS) technique to reduce the Fixed Pattern Noise (FPN) associated with traditional Active Pixel Sensors (APS). Additionally, Non-Correlated Double Sampling (NCDS) and Delta Double Sampling (DDS) are used as noise reduction techniques. An experimental optical setup is used to characterize the performance of the imager, obtaining a conversion gain of 7.3 uV/e-, a photodiode junction capacitance of 21.9 fF, a read noise of 324.5 uV, equivalent to ~45 e- and a dynamic range of 50.5 dB. The benefits of ACS and NCDS-DDS are observed in the low pixel and column FPN of 0.09% and 0.06% respectively. The work presented in this thesis is a first step towards the goal of developing a fully integrated SPR-biosensing platform incorporating light source, SPR interface, microfluidic channel, optical elements and CMOS imager.
10

Le dosage des cytochromes P450 (CYPs) humains par spectrométrie de masse : applications en toxicologie / The dosage of cytochromes P450 (CYPs) humans by mass spectrometry : applications in toxicology

Al Ali, Ahmad 10 June 2014 (has links)
Les cytochromes P450 (CYPs) jouent un rôle essentiel dans le métabolisme oxydatif de nombreux composés endogènes et exogènes. L’expression de CYPs est extrêmement variable en fonction de facteurs physiopathologiques, génétiques et environnementaux. Le métabolisme des xénobiotiques par les CYPs dépend en partie de la nature, de la quantité et de l’activité d’isoformes des CYPs impliqués. L'analyse quantitative de l'expression de CYP dans les organes du métabolisme, tels que le foie, sont d'une importance particulière étant donné que la biotransformation réalisée par les CYPs est souvent un facteur critique qui affecte l'efficacité, la disponibilité et la toxicité des médicaments chez l'homme. La technique actuelle de dosage la plus courante est l’immunoquantification par Western Blot. Cette technique est limitée par la disponibilité et la spécificité de l'anticorps. Les techniques de protéomique par spectrométrie de masse, permettant d’analyser de très faibles quantités de protéines en mélange, sont les méthodes de choix pour l’identification et la quantification des CYPs dans différents organes. Nous avons développé et validé une méthode pour doser 6 CYPs (1A2, 2C9, 2D6, 2J2, 3A4 et 3A5) par spectrométrie de masse en couplage chromatographique. Cette méthode, simple, rapide de sensibilité satisfaisante et peu coûteuse, a été validée dans différents types de matrices biologiques (lignées cellulaires hépatiques et neuronales, baculosomes). Ensuite, elle a été appliquée à grande échelle pour l’analyse de 50 foies humains (microsomes et mitochondries) afin d’étudier la relation phénotype/génotype pour les CYPs. Cette méthode pourra être appliquée à d’autres CYPS, est un outil utile qui permettra d’améliorer la compréhension et la prédiction pharmacocinétique et toxique de médicaments et d’autres produits chimiques. / Cytochromes P450 (CYPs) play a key role in the oxidative metabolism of many endogenous and exogenous compounds. The expression of CYPs is extremely variable depending on patho-physiological, genetic and environmental factors. The metabolism of xenobiotics by CYPs depends on the nature the quantity and the activity of CYP isoforms involved. Quantitative analysis of CYP expression in organs such as liver, are of particular importance since the biotransformation performed by CYPs is often a critical factor that affects the efficiency, availability and drug toxicity in humans. The most common technique is the immune-quantitation (Western Blot). This technique is limited by the availability and specificity of the antibody. Mass spectrometry-based proteomics, able to analyze very small amounts of protein in a mixture, are the methods of choice for identification and quantification of CYPs in different organs. We developed and validated a method for dosing 6 CYPs (1A2, 2C9, 2D6, 2J2, 3A4 and 3A5) by liquid chromatography coupled with mass spectrometry. This simple, rapid, low-cost method has an adequate sensitivity, and has been validated in different types of biological matrices (liver and neuronal cell lines, baculosomes). It has been applied at large-scale to analyze these 6 CYPs in 50 human livers samples (microsomes and mitochondria) to study the phenotype/genotype relationship. This method, which could easily be applied to other CYPs, provides an important tool to improve the understanding and prediction of pharmacokinetics and toxicity profile of drugs and other chemicals.