• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 1
  • Tagged with
  • 8
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dentina humana e bovina: estudo comparativo das propriedades físicas e características da hibridização de sistemas adesivos convencionais ou grander modificados: análise em mev /

Gonçalves, Sérgio Eduardo de Paiva. January 2005 (has links)
Resumo: A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilíbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades físicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada híbrida em dentina humana e bovina. A tensão superficial de quatro diferentes líquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro líquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada híbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatística de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os líquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A long-lasting adhesion is still one of the biggest challenges of the modern Dentistry. A new approach to reaching the equilibrium of the adhesion to the dental tissues emerges based on the observation of the results obtained with the Grander Technology for revitalizing water. The aim of this study was to verify the influence of this technology on the physical properties of two adhesive systems (conventional and self-etching) through the measurement of the surface tension and of the contact angle and through the evaluation of the formed hybrid layer in human and bovine dentin. The surface tension of four different liquids (water, Single Bond - 3M, Clearfil SE primer - Kuraray and Clearfil SE bond - Kuraray) was measured before and after submitting these liquids to the Grander modifying unit, with the aid of a goniometer (Ramé-hart). The measurement of the contact angle of the liquids followed the same procedure using three distinct surfaces: titanium plate, human dentin and bovine dentin. The hybrid layer formed for both: non-modified and Grander modified adhesive systems, was evaluated in SEM. For this purpose human and bovine dentin samples were prepared. The teeth were fixed in acrylic resin and the dentin surfaces exposed and finished with various grit polishing paper discs. These dentin surfaces were then treated with the adhesive procedures (normal and Grander modified), before the placement of a double composite resin layer (Z250- 3M). After storage at 37oC for 24h, the SEM analysis were conducted. The data were submitted to ANOVA and Turkeys test 5%. The results showed statistically significant reduction for the surface tension of all liquids modified by the Grander technology, as well as for the contact angle in the human dentin. Statistically significant were also the results showing a thicker hybrid layer formation with the two adhesive systems when modified by the Grander... (Complete abstract click electronic access below)
2

Influência de diferentes sistemas adesivos dentários resinosos aplicados em dentina humana frente a um desafio cariogênico bacteriano, in vitro / The influence of different resin dental adhesive systems applied to human dentine in the face of an in vitro bacterial cariogenic challenge, in vitro

Espejo, Luciana Cardoso 21 October 2008 (has links)
Neste estudo, o objetivo foi avaliar, in vitro, o comportamento de três sistemas adesivos dentários (SAD), sendo dois autocondicionantes Clearfil SE Bond Kuraray Co (CSEB) e Xeno III Dentsply (X-III) e um condicione e lave de 3 passos Scothbond Multi-Purpose Plus - 3M ESPE (SBMP), no que se refere à inibição de lesões recidivantes de cárie em dentina, frente à um desafio cariogênico bacteriano, que utilizou uma cepa de Streptococcus mutans. Além destes materiais, foi inserido no estudo um controle negativo (CN), o qual não recebeu tratamento adesivo. A amostra formada por terceiros molares humanos (n=40) foi preparada com cavidades Classe V e restaurada com a resina composta (RC) Z250 (3M ESPE), deixando-se um nicho na interface restauração/dente na parede gengival em dentina. Os quatro grupos experimentais (n=10) foram submetidos ao desafio cariogênico para o desenvolvimento das lesões durante 30 dias. Foi realizada em microscopia óptica de luz (MOL) a medição das variáveis: profundidade da lesão de parede, extensão da lesão de parede e profundidade da lesão externa e em MEV (Microscopia Eletrônica de Varredura) a análise morfológica das lesões de cárie formadas. Os dados referentes às lesões foram analisados através de Análise de Variância, testes auxiliares, além do Teste de Brown e Forsythe, com grau de significância de 5%. A metodologia adotada foi capaz de desenvolver lesões externas e de parede e de padronizar uma fenda entre restauração/dente. Em relação às variáveis estudadas, concluiu-se que o CSEB apresentou menores lesões de parede em profundidade e extensão do que os demais SAD, e que os resultados do X-III foram similares estatisticamente ao SBMP para as mesmas variáveis. Quanto a profundidade da lesão externa, todos os SAD tiveram comportamento semelhante. / The aim of this study was to evaluate the in vitro behavior of three dental adhesive systems (DAS), namely the two self etching Clearfil SE Bond Kuraray Co (CSEB) and Xeno III Dentsply (X-III) as well as the three-step etch and rinse Multi-Purpose Plus 3M ESPE (SBMP), concerning the inhibition of secondary dentine caries in the face of a bacterial cariogenic challenge using Streptococcus mutans. Besides the aforementioned material, a negative control group (NC) which did not receive any adhesive treatment was included in this study. The sample, which consisted of human third molars (n=40), in which class-V cavities prepares were restored with the composite resin (CR) Z250 (3M ESPE). An interfacial gap was left between teeth and restorations in the dentinal gingival wall. The four experimental groups (n=10) were exposed to a cariogenic challenge during 30 days. Light Optical Microscopy (LOM) was used to measure wall caries lesion depth, wall caries lesion extension and outer caries lesion depth. SEM (Scanning Electron Microscopy) was the method chosen for the morphological analysis of the formed carie lesions. The data regarding lesions was analyzed through Analysis of Variance and Component of Variance Model in addition to the Brown-Forsythe test at a 5% significance level. The adopted methodology could develop external and wall lesions, also standardizing a gap between restorations and teeth. About the studied variables, it was possible to conclude that CSEB presented the smallest wall lesions both in depth and extension, and the X-III and SBMP results were statistically similar concerning the same variables. Regarding outer lesion depth, all DAS showed similar behaviour.
3

Efeito do jateamento com vidro niobofosfato na resistência de união de um adesivo em dentina afetada por cárie / Effect of blasting with niobophosphate glass on the bond strength of an adhesive in dentin affected by caries

LEAL, Adriana Mara Araujo 29 February 2016 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-08-31T20:05:30Z No. of bitstreams: 1 Tese-AdrianaMaraAraujoLeal.pdf: 1605470 bytes, checksum: 5e809d0da87d46e2077716ab7023a4a6 (MD5) / Made available in DSpace on 2017-08-31T20:05:30Z (GMT). No. of bitstreams: 1 Tese-AdrianaMaraAraujoLeal.pdf: 1605470 bytes, checksum: 5e809d0da87d46e2077716ab7023a4a6 (MD5) Previous issue date: 2016-02-29 / FAPEMA / Objectives: To evaluate the effect of airborne-particle abrasion with niobium phosphate bioglass (NbG) microparticles on the bond strength (µTBS) and longevity of an adhesive system to different dentin substrates. Methods and Materials: Caries-free molars were used in this study. The dentin surfaces were evaluated in three groups: (1) Control – Healthy Dentin; (2) Partial removal of carious tissue; (3) complete removal of carious tissue. Half the teeth in each group were submitted to airborne-particle abrasion with NbG microparticles (15s/1cm/5bar). After this, the adhesive Clearfil S3 was applied and composite buildups were constructed incrementally; and specimens were longitudinally sectioned to obtain bonded sticks (1.0 mm2) to be tested in tension (0.5 mm/min) immediately or after 6 months of storage in water. The fracture patterns were evaluated by stereomicroscope (40x) and then by scanning electron microscopy (SEM). The data were analyzed by the Kruskal-Wallis (post-hoc Dunn) and Mann-Whitney tests (α=0.05). Results: Healthy dentin showed the highest bond strength (µTBS). Airborne-particle abrasion with NbG increased the µTBS values in the complete caries removal group. The bond strength values in the 24-hr period were higher than those at 6 months. In the majority of the specimens the fracture mode was adhesive/ mixed. Conclusion: The authors concluded that airborne-particle abrasion on dentin with NbG particles increased the µTBS in the group in which carious dentin was completely removed. / Objetivo: Avaliar o efeito do jateamento de micropartículas de vidro niobofosfato (NbG) na resistência de união (RU) e na longevidade de um sistema adesivo em diferentes substratos dentinários. Dezoito molares extraídos livres de cárie foram usados. As superfícies de dentina foram avaliadas em três grupos: (1) Controle – Dentina Sadia; (2) Remoção parcial do tecido cariado; (3) Remoção total do tecido cariado. Metade dos dentes de cada grupo sofreu um jateamento com partículas de NbG (15s/1cm/5bar). Em seguida o adesivo Clearfil S3 Bond Plus foi aplicado e uma coroa de resina composta foi construída. Os dentes foram seccionados para obtenção dos espécimes (1,0 mm2) e submetidos ao teste de microtração (0,5 mm/min) imediatamente e após 6 meses de estocagem em água. Os padrões de fratura foram avaliados usando estereomicroscópio (40x) e levados ao microscópio eletrônico de varredura (SEM). Os dados foram analisados pelos testes Kruskal-Wallis (pos-hoc Dunn) e Mann-Whitney (α=0.05). Resultados: A dentina sadia apresentou os maiores valores de RU. O jateamento com NbG aumentou os valores de RU no grupo remoção total. Os valores de RU no período de 24h foram superiores ao de 6 meses. A maioria das fraturas dos espécimes foi adesiva/mista. Conclusão: Os autores concluíram que o jateamento à dentina com partículas NbG aumentou a RU no grupo onde a dentina cariada foi totalmente removida.
4

Influência de diferentes sistemas adesivos dentários resinosos aplicados em dentina humana frente a um desafio cariogênico bacteriano, in vitro / The influence of different resin dental adhesive systems applied to human dentine in the face of an in vitro bacterial cariogenic challenge, in vitro

Luciana Cardoso Espejo 21 October 2008 (has links)
Neste estudo, o objetivo foi avaliar, in vitro, o comportamento de três sistemas adesivos dentários (SAD), sendo dois autocondicionantes Clearfil SE Bond Kuraray Co (CSEB) e Xeno III Dentsply (X-III) e um condicione e lave de 3 passos Scothbond Multi-Purpose Plus - 3M ESPE (SBMP), no que se refere à inibição de lesões recidivantes de cárie em dentina, frente à um desafio cariogênico bacteriano, que utilizou uma cepa de Streptococcus mutans. Além destes materiais, foi inserido no estudo um controle negativo (CN), o qual não recebeu tratamento adesivo. A amostra formada por terceiros molares humanos (n=40) foi preparada com cavidades Classe V e restaurada com a resina composta (RC) Z250 (3M ESPE), deixando-se um nicho na interface restauração/dente na parede gengival em dentina. Os quatro grupos experimentais (n=10) foram submetidos ao desafio cariogênico para o desenvolvimento das lesões durante 30 dias. Foi realizada em microscopia óptica de luz (MOL) a medição das variáveis: profundidade da lesão de parede, extensão da lesão de parede e profundidade da lesão externa e em MEV (Microscopia Eletrônica de Varredura) a análise morfológica das lesões de cárie formadas. Os dados referentes às lesões foram analisados através de Análise de Variância, testes auxiliares, além do Teste de Brown e Forsythe, com grau de significância de 5%. A metodologia adotada foi capaz de desenvolver lesões externas e de parede e de padronizar uma fenda entre restauração/dente. Em relação às variáveis estudadas, concluiu-se que o CSEB apresentou menores lesões de parede em profundidade e extensão do que os demais SAD, e que os resultados do X-III foram similares estatisticamente ao SBMP para as mesmas variáveis. Quanto a profundidade da lesão externa, todos os SAD tiveram comportamento semelhante. / The aim of this study was to evaluate the in vitro behavior of three dental adhesive systems (DAS), namely the two self etching Clearfil SE Bond Kuraray Co (CSEB) and Xeno III Dentsply (X-III) as well as the three-step etch and rinse Multi-Purpose Plus 3M ESPE (SBMP), concerning the inhibition of secondary dentine caries in the face of a bacterial cariogenic challenge using Streptococcus mutans. Besides the aforementioned material, a negative control group (NC) which did not receive any adhesive treatment was included in this study. The sample, which consisted of human third molars (n=40), in which class-V cavities prepares were restored with the composite resin (CR) Z250 (3M ESPE). An interfacial gap was left between teeth and restorations in the dentinal gingival wall. The four experimental groups (n=10) were exposed to a cariogenic challenge during 30 days. Light Optical Microscopy (LOM) was used to measure wall caries lesion depth, wall caries lesion extension and outer caries lesion depth. SEM (Scanning Electron Microscopy) was the method chosen for the morphological analysis of the formed carie lesions. The data regarding lesions was analyzed through Analysis of Variance and Component of Variance Model in addition to the Brown-Forsythe test at a 5% significance level. The adopted methodology could develop external and wall lesions, also standardizing a gap between restorations and teeth. About the studied variables, it was possible to conclude that CSEB presented the smallest wall lesions both in depth and extension, and the X-III and SBMP results were statistically similar concerning the same variables. Regarding outer lesion depth, all DAS showed similar behaviour.
5

Efeito do jateamento com vidro niobofosfato na resistência de união de um adesivo em dentina afetada por cárie / Effect of blasting with niobophosphate glass on the bond strength of an adhesive in dentin affected by caries

Leal, Adriana Mara Araújo 29 February 2016 (has links)
Submitted by Rosivalda Pereira (mrs.pereira@ufma.br) on 2017-05-10T20:18:37Z No. of bitstreams: 1 AdrianaLeal.pdf: 1605345 bytes, checksum: 700a558a6725b2db9159b45c403c2cbb (MD5) / Made available in DSpace on 2017-05-10T20:18:37Z (GMT). No. of bitstreams: 1 AdrianaLeal.pdf: 1605345 bytes, checksum: 700a558a6725b2db9159b45c403c2cbb (MD5) Previous issue date: 2016-02-29 / Fundação de Amparo à Pesquisa e ao Desenvolvimento Científico e Tecnológico do Maranhão (FAPEMA) / Objectives: To evaluate the effect of airborne-particle abrasion with niobium phosphate bioglass (NbG) microparticles on the bond strength (µTBS) and longevity of an adhesive system to different dentin substrates. Methods and Materials: Caries-free molars were used in this study. The dentin surfaces were evaluated in three groups: (1) Control – Healthy Dentin; (2) Partial removal of carious tissue; (3) complete removal of carious tissue. Half the teeth in each group were submitted to airborne-particle abrasion with NbG microparticles (15s/1cm/5bar). After this, the adhesive Clearfil S3 was applied and composite buildups were constructed incrementally; and specimens were longitudinally sectioned to obtain bonded sticks (1.0 mm2) to be tested in tension (0.5 mm/min) immediately or after 6 months of storage in water. The fracture patterns were evaluated by stereomicroscope (40x) and then by scanning electron microscopy (SEM). The data were analyzed by the Kruskal-Wallis (post-hoc Dunn) and Mann-Whitney tests (α=0.05). Results: Healthy dentin showed the highest bond strength (µTBS). Airborne-particle abrasion with NbG increased the µTBS values in the complete caries removal group. The bond strength values in the 24-hr period were higher than those at 6 months. In the majority of the specimens the fracture mode was adhesive/ mixed. Conclusion: The authors concluded that airborne-particle abrasion on dentin with NbG particles increased the µTBS in the group in which carious dentin was completely removed. / Objetivo: Avaliar o efeito do jateamento de micropartículas de vidro niobofosfato (NbG) na resistência de união (RU) e na longevidade de um sistema adesivo em diferentes substratos dentinários. Dezoito molares extraídos livres de cárie foram usados. As superfícies de dentina foram avaliadas em três grupos: (1) Controle – Dentina Sadia; (2) Remoção parcial do tecido cariado; (3) Remoção total do tecido cariado. Metade dos dentes de cada grupo sofreu um jateamento com partículas de NbG (15s/1cm/5bar). Em seguida o adesivo Clearfil S3 Bond Plus foi aplicado e uma coroa de resina composta foi construída. Os dentes foram seccionados para obtenção dos espécimes (1,0 mm2) e submetidos ao teste de microtração (0,5 mm/min) imediatamente e após 6 meses de estocagem em água. Os padrões de fratura foram avaliados usando estereomicroscópio (40x) e levados ao microscópio eletrônico de varredura (SEM). Os dados foram analisados pelos testes Kruskal-Wallis (pos-hoc Dunn) e Mann-Whitney (α=0.05). Resultados: A dentina sadia apresentou os maiores valores de RU. O jateamento com NbG aumentou os valores de RU no grupo remoção total. Os valores de RU no período de 24h foram superiores ao de 6 meses. A maioria das fraturas dos espécimes foi adesiva/mista. Conclusão: Os autores concluíram que o jateamento à dentina com partículas NbG aumentou a RU no grupo onde a dentina cariada foi totalmente removida.
6

Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantes

Lanza, Célia Regina Moreira [UNESP] 06 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-06Bitstream added on 2014-06-13T19:43:57Z : No. of bitstreams: 1 lanza_crm_dr_arafo.pdf: 5945078 bytes, checksum: 092aa2094ca72bbfeb2e0b5301a1b69e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente. / This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin.
7

Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantes /

Lanza, Célia Regina Moreira. January 2007 (has links)
Orientador: Josemeri Hebling / Banca: Roberval de Almeida Cruz / Banca: José Carlos Pereira / Banca: Elisa Maria Aparecida Giro / Banca: Carlos Alberto dos Santos Cruz / Resumo: Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente. / Abstract: This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin. / Doutor
8

Analyse d'une interface adhérente dentine/titane en fonction de différents matériaux d'assemblage / Study of a dentin adhesive / titanium interface mediated by different resin luting cement

Schittly, Estelle 18 April 2016 (has links)
Le fil directeur durant cette période de recherche a été l’étude d’une interface dentine/titane assemblée par collage. L’objectif était d’optimiser et de simplifier des étapes du protocole d’assemblage, d’améliorer et d’étudier les performances de l’interface adhérente. Dans ce travail, les interfaces ont été testées in vitro par cisaillement.Cette étude a comporté trois volets :Le but de la première étude a été d’évaluer un assemblage par ciment verre ionomère (CVI), le Fuji Plus®, appliqué en association avec des adhésifs auto-mordançants sur la dentine. Trois des combinaisons « système auto-mordançant/Fuji Plus® » ont été appliquées et les résultats obtenus montrent des améliorations significatives entre 9% et 44% par rapport aux valeurs obtenues sur des éprouvettes de témoin.Le second volet expérimental a eu pour objectif de tester la compatibilité entre cinq systèmes adhésifs auto-mordançants (SAM) et deux composites d’assemblage (CA). Les SAM1 se sont révélés totalement incompatibles avec les CA chémopolymérisés ou duals. Inversement, les SAM2 étaient compatibles avec des CA chémopolymérisants ou duals. Une corrélation positive a été trouvée entre le pH des SAM ou les résines testées et les données de cisaillement.La dernière étude a été dédiée à l’évaluation de l'effet du stockage dans l’eau sur la résistance à la flexion (σf) et sur la résistance au cisaillement (RC) d’une interface dentine/titane assemblée par quatre résines adhésives auto-mordançantes (MRAM). Cette étude a montré que le stockage dans l'eau durant 60 jours a affecté négativement la résistance à la flexion de certains matériaux. L'adhésion dentine/titane offerte par Rely X® et G-Cem® était significativement plus élevée que celle de Maxcem® et SmartCem2®. / The aim of this work was to study a bonding dentin/titanium interface. The objective was to optimize and simplify the steps of the bonding protocol, improve and know well the performance of the adhesive interface. In this work, all interfaces have been tested in vitro by shearing.This study included three parts :The purpose of the first study was to evaluate an assemblage by glass ionomer cement (GIC), the Fuji plus®, applied in combination with self-etch bonding system on dentin. Three combinations "system self-etching / Fuji Plus®" were applied and the results obtained by test showed significant improvements from 9% to 44% higher than the values obtained on control specimens.The second experimental part was designed to test the compatibility between five self-etch bonding systems (SEBS) and two resin luting cements (RLC). Significant differences of bond strength in shear were observed according to both the curing mode of the RLC and the adhesive. The SEBS1 proved totally incompatible with chemical or dual cured RLC. Conversely, two-steps SEBS were compatible with RLC chemical/dual cured RLC. A positive correlation was found between the pH of the SEBS or the tested resins and the shear data.The latest study was devoted to evaluate the effect of the storage condition on flexural strength (σf) and shear bond strength (SBS) of a dentin/titanium interface assembled by four self-etch adhesive resin (SEARC). This study showed that the storage in water for 60 days has negatively affected the bending resistance of certain materials. The dentin/titanium adherence offered by Rely X® and G-Cem® was significantly higher than that of Maxcem® and SmartCem2®.

Page generated in 0.0949 seconds