Spelling suggestions: "subject:"aminais eletromiográfico"" "subject:"aminais eletromiográfica""
1 |
Compressão de sinais de eletromiografia utilizando transformada de Wavelets e alocação de bits por sub-bandasTrabuco, Marcel Henrique 17 August 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2012. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-01-10T12:48:01Z
No. of bitstreams: 1
2012_MarcelHenriqueTrabuco.pdf: 10707374 bytes, checksum: 9fb7b5419b9c44273d681f72ba45d112 (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2013-01-28T13:26:43Z (GMT) No. of bitstreams: 1
2012_MarcelHenriqueTrabuco.pdf: 10707374 bytes, checksum: 9fb7b5419b9c44273d681f72ba45d112 (MD5) / Made available in DSpace on 2013-01-28T13:26:43Z (GMT). No. of bitstreams: 1
2012_MarcelHenriqueTrabuco.pdf: 10707374 bytes, checksum: 9fb7b5419b9c44273d681f72ba45d112 (MD5) / Em face ao crescente uso de sinais de eletromiografia pela medicina, é imprescindível a otimização do processo de codificação dos sinais envolvidos. Assim, esta pesquisa visa colaborar com essa crescente necessidade. Aqui é apresentado um codificador de sinais
baseado em transformada Wavelet e alocação de bits por sub-bandas. Foram implementadas e comparadas três formas distintas de alocação de bits: exponencial, linear e raiz-quadrática, todas decrescentes. Comparações com outros codificadores presentes na literatura são apresentadas. Verificou-se que alocação raiz-quadrática decrescente aplicada a alocação de bits por sub-banda gerou um melhor resultado quando comparada com as outras formas de alocação e resultados melhores ou semelhantes foram alcançados na
comparação com outros codificadores presentes na literatura. No esenvolvimento do codificador, buscou-se sempre a máxima compressão, mas sem a perda de fidelidade do sinal reconstruído, característica fundamental da análise de sinais eletromiográficos. ______________________________________________________________________________ ABSTRACT / Given the increasing use of electromyographic signals by the medicine, is essential to optimize the process of encoding the signals involved. So this research intends to collaborate with this growing need. In this work, an encoder signal based on wavelet transform and bit allocation for sub-bands is presented. Were implemented and compared three methods of allocating bits: exponential, linear and quadratic-root, all decreasing. It
was found that decreasing quadratic-root allocation applied to the bits allocation per sub-band produced the best results when compared with other forms of allocation and similar or better results were achieved in comparison to other encoders in the literature. In the development of the encoder, always sought to maximum compression, but without loss of
fidelity of the reconstructed signal, a fundamental characteristic of the analysis of electromyographic signals.
|
2 |
Parâmetros discriminadores de estacionariedade fisiológica em sinais de eletromiografia de superfície aplicados no estudo da fadiga / Discriminatory parameters for physiological stationarity in surface electromyography applied in fatigue analysisRocha Júnior, Valdinar de Araújo 22 November 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2017-02-23T16:15:43Z
No. of bitstreams: 1
2016_ValdinardeAraújoRochaJúnior.pdf: 4581584 bytes, checksum: e9f5e7a03217d7a664a1063c3e8ee236 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-03-13T20:05:38Z (GMT) No. of bitstreams: 1
2016_ValdinardeAraújoRochaJúnior.pdf: 4581584 bytes, checksum: e9f5e7a03217d7a664a1063c3e8ee236 (MD5) / Made available in DSpace on 2017-03-13T20:05:38Z (GMT). No. of bitstreams: 1
2016_ValdinardeAraújoRochaJúnior.pdf: 4581584 bytes, checksum: e9f5e7a03217d7a664a1063c3e8ee236 (MD5) / A presente investigação tem como objeto de estudo o processamento do sinal eletromiográfico utilizado na análise da fadiga muscular. As técnicas de processamento de sinais tradicionalmente aplicadas à eletromiografia de superfície (EMG-S) produzem índices de fadiga com grande variação espacial (os índices sofrem grandes distorções por conta de mudanças na posição dos eletrodos de captação). Os índices de fadiga obtidos com técnicas clássicas também exibem grande variação temporal (eles não apresentam o mesmo resultado quando o procedimento experimental é repetido duas ou mais vezes). Com a finalidade de superar essas limitações, três novos parâmetros eletromiográficos que destacam as faixas de frequência mais reprodutíveis do sinal foram desenvolvidos: o escalar ponderado de Fourier (scale weighted Fourier – SWF); o escalar ponderado wavelet (scale weighted wavelet – SWW) e a razão wavelet entre a energia das escalas de baixa frequência e a energia total dos coeficientes (wavelet index of ratio of energies at scales of low frequency and wavelets energy – WIRELT). Além da criação de novos parâmetros, uma nova metodologia de análise de sinal também foi concebida para reduzir os problemas de variação espacial e temporal dos índices. Tal metodologia baseia-se em modelo estocástico markoviano que indica a não estacionariedade introduzida no sinal eletromiográfico pela fadiga utilizando processo de acumulação de parâmetros. A avaliação do modelo proposto foi feita em conjunto de sinais reais captados no bíceps braquial de homens e mulheres durante contração isométrica fatigante. Os sinais foram registrados com arranjo linear de eletrodos e o modelo estocástico foi aplicado tanto aos novos parâmetros desenvolvidos quanto aos parâmetros clássicos descritos na literatura (RMS, ZCR, MDF e WIRELT). As avaliações realizadas mostraram que os novos parâmetros são capazes de ressaltar as faixas de frequência mais reprodutíveis do sinal de EMG-S. Verificou-se também que o modelo estocástico indica a fadiga muscular independente do parâmetro eletromiográfico ao qual ele é aplicado. Com a utilização do novo modelo, alguns parâmetros tornam-se mais ou menos sensíveis à fadiga, dependendo da intensidade da contração isométrica. Em relação à variação espacial e temporal, os índices de fadiga obtidos com o novo processamento mostraram-se mais reprodutíveis que os índices calculados com métodos tradicionais. A nova metodologia também permitiu diferenciar a taxa de fadiga de homens e mulheres e sinalizar a fadiga mais acentuada em indivíduos que realizaram teste com maior intensidade de contração. Os resultados do presente estudo indicam que o processamento proposto constitui ferramenta de análise eletromiográfica da fadiga que minimiza os problemas identificados nas abordagens clássicas de tratamento do sinal de EMG-S. / The study object of the present investigation is the signal processing of electromyography signal used in muscular fatigue analysis. The traditional signal process techniques applied in surface electromyography produce fatigue indexes with high spatial variance (the indexes are distorted with electrode positioning changes). The fatigue indexes coming from classic techniques also show high temporal variance (they do no present the same result when experimental procedure is repeated twice or more times). Aiming to overcome these limitations, three new electromyographic parameters that highlight the most reliably signal frequency bands were developed: the scale weighted Fourier (SWF); the scale weighted wavelet (SWW) and the wavelet index of ratio of energies at scales of low frequency and wavelets energy (WIRELT). Besides the development of new parameters, a new methodology for signal analysis was conceived to minimize problems with spatial and temporal indexes variations. This methodology is based on a markovian stochastic model that indicates the non-stationarity inserted in electromyographic signal by the fatigue using a cumulative parameters process. The evaluation of the proposed model was performed in a set of real signals obtained in biceps brachii of men and women during isometric fatiguing contractions. The signals were acquired by a linear electrode array and the stochastic model was applied in the new and in the classic electromyographic parameters described in literature (RMS, ZCR, MDF e WIRELT). The evaluation performed showed that the new parameters are able to highlight the most reliable signal frequency bands of the EMG-S. It was found that stochastic model indicates the muscular fatigue regardless of the parameter in which it is applied. With the use of the new model, some parameters became more or less sensitive to fatigue depending on isometric contraction intensity. In relation to spatial and temporal variation, the fatigue indexes established with new signal processing have revealed to be more reliable than the ones obtained with traditional methods. The new signal processing also allowed to distinguish the fatigue rates in men and women, and indicated steeper fatigue rate in tests with more intense contractions. The results of the present study showed that the signal processing proposed is an electromyographic tool that minimizes the problems identified in classical approaches for EMG-S signal treatment.
|
3 |
Definição de parâmetros para o estudo da fadiga muscular em exercícios dinâmicos utilizando a metodologia acumulativa-normalizada por meio de eletromiografiaSilva, Hédipo José Ribeiro e 17 August 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2018. / Esta dissertação compreende o estudo da fadiga muscular, e aborda a determinação de parâmetros que possibilitem a avaliação objetiva da fadiga muscular em esforços físicos dinâmicos utilizando EMG-S (eletromiografia de superfície). O trabalho tem enfase na busca que parâmetros que permitam a repetibilidade da avaliação em diferentes voluntários e diferentes tipos de esforços físicos. Além de índices indicadores de fadiga já consolidados na literatura, usar-se-á um indicador demostrado pelo grupo de pesquisa da Universidade de Brasília, que mostrou bastante eficácia e sensibilidade quanto à evolução da fadiga muscular. Tanto para este parâmetro quanto para os outros abordou-se, além da verificação direta dos indicadores uma análise com indicadores acumulativos. As avaliações realizadas mostraram que, ajustando os parâmetros de processamento de sinais flexivelmente de acordo com cada sinal, tanto os novos quanto os parâmetros clássicos se mostram tão promissores na análise de exercícios dinâmicos como já observado na análise de exercícios isostáticos. Os modelos determinantes de indicadores de fadiga através de EMG-S mostraram um grau de reprodutibilidade alvissareiro em relação a diferentes pessoas, diferente exercício e diferentes músculos de estudo. / This work comprises the study of muscle fatigue and addresses the determination of parameters that allow the objective evaluation of muscle fatigue in dynamic physical efforts using EMG-S(surface electromyography). The work focuses on the search for parameters that allow the repeatability of the evaluation in different volunteers and different types of physical efforts. In addition to indexes of fatigue already consolidated in the literature, an indicator will be used, demonstrated by the research group of the University of Brasília, which showed a great deal of efficacy and sensitivity regarding the evolution of muscular fatigue. For both this parameter and the others, it was approached, besides the direct verification of the indicators, an analysis with cumulative indicators. The evaluations showed that by adjusting the signal processing parameters flexibly according to each signal, both the new and the classical parameters are shown as promising in the analysis of dynamic exercises as already observed in the analysis of isotactic exercises. The determinant models of fatigue indicators through EMG-S showed a degree of reproducibility in relation to different people, different exercise and different study muscles.
|
4 |
Estudo do comportamento do sinal eletromiográfico de superfície em atividades subaquáticasVeneziano, Wilson Henrique 24 April 2006 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2006. / Submitted by mariana castro (nanacastro0107@hotmail.com) on 2009-12-01T19:16:56Z
No. of bitstreams: 1
tese Wilson Henrique Veneziano - eng eletrica.pdf: 6826947 bytes, checksum: 60507809db546d0f1f8cb14afe1f61b6 (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2009-12-03T13:15:27Z (GMT) No. of bitstreams: 1
tese Wilson Henrique Veneziano - eng eletrica.pdf: 6826947 bytes, checksum: 60507809db546d0f1f8cb14afe1f61b6 (MD5) / Made available in DSpace on 2009-12-03T13:15:27Z (GMT). No. of bitstreams: 1
tese Wilson Henrique Veneziano - eng eletrica.pdf: 6826947 bytes, checksum: 60507809db546d0f1f8cb14afe1f61b6 (MD5)
Previous issue date: 2006-04-24 / Nesta tese de doutorado em Engenharia Elétrica foram desenvolvidas metodologias para a aquisição, o processamento e a interpretação de sinais eletromiográficos (EMG) de superfície em ambientes subaquáticos. Também se estudou o efeito do ambiente aquático sobre as variáveis eletromiográficas. Quatro experimentos contemplando os músculos abdutor curto do polegar e bíceps braquial foram realizados em ambientes aéreo e subaquático. No primeiro experimento, foi avaliada a repetibilidade de um protocolo envolvendo contrações isométricas do abdutor curto do polegar, tendo o resultado mostrado uma boa repetibilidade do processo de captação e processamento do EMG. Esse protocolo foi utilizado no segundo experimento, cujo objetivo foi o de avaliar se existem diferenças nas variáveis do sinal de EMG (amplitude e parâmetros espectrais) medido no ar e na água. Não foram encontradas diferenças estatisticamente significativas. Em um terceiro experimento, o sinal de EMG do bíceps braquial foi medido nos ambientes aéreo e subaquático, tanto em situação de imersão somente do membro superior como de imersão do corpo até a altura da vértebra C7. Foram encontradas diferenças significativas entre os ambientes; entretanto, o resultado foi o oposto quando uma pulseira especial compensadora do empuxo foi utilizada no ambiente subaquático. Ou seja, o experimento mostrou que ocorre diferença na amplitude do sinal de EMG em água somente quando não são compensadas as forças de empuxo e de arrasto. Um quarto experimento contemplou contrações dinâmicas do bíceps braquial, em ambientes aéreo e subaquático. Concluiu-se que, desde que compensados os fatores perturbadores (forças de empuxo e de arrasto e temperatura da água), o valor retificado médio, a freqüência média e a velocidade de condução das fibras musculares não apresentam diferença significativa quando o sinal é captado em um meio ou no outro. Outra contribuição é que os trabalhos desta tese de doutorado apresentam uma metodologia cuidadosa para a captação e o processamento de sinais eletromiográficos de superfície em ambientes subaquáticos. _______________________________________________________________________________ ABSTRACT / In this doctoral thesis in Electrical Engineering, methodologies for acquisition, processing and interpretation of the surface electromyographic (EMG) signals in underwater environments were developed. The effect of the aqueous environment on the electromyographic variables was studied as well. Four experiments involving both the abductor pollicis brevis and the biceps brachii muscles were performed in aerial and in underwater conditions. In the first experiment, the repeatability of a protocol involving isometric contractions of the abductor pollicis brevis muscle was evaluated, and the results showed that the protocol developed has a good repeatability. This protocol was used in the second experiment, whose goal was to evaluate if there are differences in the electromyographic variables (amplitude and spectral parameters) measure in air or underwater. The results showed no significant differences between the electromyographic variables in the two environments. In the third experiment, the electromyographic signal was measured in the biceps brachii, in both aerial and underwater environments for both total body immersion and only the immersion of the limb. The experiment showed significant differences between the electromyographic variables measured in the two environments. However, when the effect of the buoyancy force exerted by the water on the arm was compensated for, no significant differences were found. This experiment showed that decreases in EMG variables measured in water are just due to the buoyancy effects and that, once these effects are counteracted, there are no differences between the electromyographic variables measured in the two environments. In the fourth experiment the electromyographic signal was measured in the biceps brachii, during dynamic contractions, for both air and aqueous environments. Several electromyographic measurements (average rectified value, mean freque ncy and conduction velocity) were studied, and the results showed that, if the effects of water temperature and of buoyancy and dragging forces of the water are properly counteracted, then there are no significant differences in the electromyographic measurements. These results are important, since it settles the fact that there is no effect of water on the electromyographic signals other than the buoyancy and dragging forces. The work is also important because it presents different techniques for dealing with and for analyzing surface EMG signals measured in underwater environments.
|
5 |
Compressão de sinais eletromiográficos baseada em técnicas bidimensionaisMelo, Wheidima Carneiro de 27 June 2014 (has links)
Submitted by Kamila Costa (kamilavasconceloscosta@gmail.com) on 2015-06-15T22:12:07Z
No. of bitstreams: 1
Dissertacao-Wheidima C de Melo.pdf: 2703087 bytes, checksum: e6e1c33a03cbfdb7ab483f0f6f9e6dc7 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T15:15:11Z (GMT) No. of bitstreams: 1
Dissertacao-Wheidima C de Melo.pdf: 2703087 bytes, checksum: e6e1c33a03cbfdb7ab483f0f6f9e6dc7 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T15:16:09Z (GMT) No. of bitstreams: 1
Dissertacao-Wheidima C de Melo.pdf: 2703087 bytes, checksum: e6e1c33a03cbfdb7ab483f0f6f9e6dc7 (MD5) / Made available in DSpace on 2015-06-16T15:16:09Z (GMT). No. of bitstreams: 1
Dissertacao-Wheidima C de Melo.pdf: 2703087 bytes, checksum: e6e1c33a03cbfdb7ab483f0f6f9e6dc7 (MD5)
Previous issue date: 2014-06-27 / Não Informada / Traditionally, electromyographic signals are compressed to one-dimensional techniques, which are specifically developed for this purpose. However, some studies have shown that the compression of biological signals such as images, via its pre-processing and rearrangement on a two-dimensional array, can lead to good results. The present work an investigation of the compression electromyographic signals like images, three main contributions: the use of new encoders, the development of new pre-processing techniques and modification of the coding core of a specific compressor, so that existing redundancies are better exploited. With respect to the pre-processing of the signal, two new techniques are introduced: ordering a percentage difference and targeting similarity which have the potential to increase the performance of encoded pictures. Optionally for compression of electromyographic signals, propose to the high efficiency video coding encoder, which features state of the art in video compression. Furthermore, an investigation of the paradigm that uses recurrence multiscale standards, known as multidimensional multiscale parser, is also presented. In summary, the encoder adapts to working with the biological signal by replacing its prediction techniques to improve the exploitation of redundancy, the result of which is termed Bio-MMP. The experiments performed with real electromyographic signals show that the proposed techniques are effective, providing better results than the state of the art in the literature. / Tradicionalmente, sinais eletromiográficos são comprimidos com técnicas unidimensionais, que são desenvolvidas especificamente para esse fim. No entanto, alguns trabalhos têm demonstrado que a compressão de sinais biológicos como imagens, através do seu pré-processamento e rearranjo em uma matriz bidimensional, pode levar a bons resultados. O presente trabalho apresenta uma investigação sobre a compressão de sinais eletromiográficos como imagens, com três principais contribuições: a utilização de novos codificadores, o desenvolvimento de novas técnicas de pré-processamento e a modificação do núcleo de codificação de um compressor específico, de modo que as redundâncias existentes sejam melhor exploradas. No que diz respeito ao pré-processamento do sinal, duas novas técnicas são introduzidas: a ordenação por diferença percentual e a segmentação por similaridade, que apresentam o potencial de aumentar o desempenho do codificados de imagens. Como opção para compressão de sinais eletromiográficos, propõem-se o codificador high efficiency video coding, que apresenta o estado da arte em compressão de vídeo. Além disso, uma investigação do paradigma que utiliza recorrência de padrões multiescalas, conhecido como multidimensional multiscale parser, também é apresentada. Em resumo, adapta-se o codificador para trabalhar com o sinal biológico, através da substituição das suas técnicas de predição, de modo a melhorar a exploração de redundâncias, cujo resultado é denominado de MMP-Bio. Os experimentos realizado com sinais eletromiográficos reais mostram que as técnicas propostas são eficazes, proporcionando resultados superiores ao estado da arte presente na literatura.
|
6 |
Seleção de características para identificação de diferentes proporções de tipos de fibras musculares por meio da eletromiografia de superfícieFreitas, Amanda Medeiros de 14 August 2015 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / Skeletal muscle consists of muscle fiber types that have different physiological and
biochemical characteristics. Basically, the muscle fiber can be classified into type I and
type II, presenting, among other features, contraction speed and sensitivity to fatigue
different for each type of muscle fiber. These fibers coexist in the skeletal muscles
and their relative proportions are modulated according to the muscle functionality and
the stimulus that is submitted. To identify the different proportions of fiber types in the
muscle composition, many studies use biopsy as standard procedure. As the surface
electromyography (EMGs) allows to extract information about the recruitment of different
motor units, this study is based on the assumption that it is possible to use the
EMG to identify different proportions of fiber types in a muscle.
The goal of this study was to identify the characteristics of the EMG signals which
are able to distinguish, more precisely, different proportions of fiber types. Also was
investigated the combination of characteristics using appropriate mathematical models.
To achieve the proposed objective, simulated signals were developed with different
proportions of motor units recruited and with different signal-to-noise ratios. Thirteen
characteristics in function of time and the frequency were extracted from emulated
signals. The results for each extracted feature of the signals were submitted to the
clustering algorithm k-means to separate the different proportions of motor units recruited
on the emulated signals. Mathematical techniques (confusion matrix and analysis
of capability) were implemented to select the characteristics able to identify different
proportions of muscle fiber types. As a result, the average frequency and median frequency
were selected as able to distinguish, with more precision, the proportions of
different muscle fiber types.
Posteriorly, the features considered most able were analyzed in an associated way
through principal component analysis. Were found two principal components of the signals emulated without noise (CP1 and CP2) and two principal components of the
noisy signals (CP1 and CP2 ). The first principal components (CP1 and CP1 ) were
identified as being able to distinguish different proportions of muscle fiber types.
The selected characteristics (median frequency, mean frequency, CP1 and CP1 )
were used to analyze real EMGs signals, comparing sedentary people with physically
active people who practice strength training (weight training). The results obtained
with the different groups of volunteers show that the physically active people obtained
higher values of mean frequency, median frequency and principal components compared
with the sedentary people. Moreover, these values decreased with increasing
power level for both groups, however, the decline was more accented for the group
of physically active people. Based on these results, it is assumed that the volunteers
of the physically active group have higher proportions of type II fibers than sedentary
people.
Finally, based on these results, we can conclude that the selected characteristics
were able to distinguish different proportions of muscle fiber types, both for the emulated
signals as to the real signals. These characteristics can be used in several studies,
for example, to evaluate the progress of people with myopathy and neuromyopathy
due to the physiotherapy, and also to analyze the development of athletes to improve
their muscle capacity according to their sport. In both cases, the extraction of these
characteristics from the surface electromyography signals provides a feedback to the
physiotherapist and the coach physical, who can analyze the increase in the proportion
of a given type of fiber, as desired in each case. / A musculatura esquelética é constituída por tipos de fibras musculares que possuem
características fisiológicas e bioquímicas distintas. Basicamente, elas podem
ser classificadas em fibras do tipo I e fibras do tipo II, apresentando, dentre outras
características, velocidade de contração e sensibilidade à fadiga diferentes para cada
tipo de fibra muscular. Estas fibras coexistem na musculatura esquelética e suas proporções
relativas são moduladas de acordo com a funcionalidade do músculo e com
o estímulo a que é submetido. Para identificar as diferentes proporções de tipos de
fibra na composição muscular, muitos estudos utilizam a biópsia como procedimento
padrão. Como a eletromiografia de superfície (EMGs) nos permite extrair informações
sobre o recrutamento de diferentes unidades motoras, este estudo parte da hipótese
de que seja possível utilizar a EMGs para identificar diferentes proporções de tipos de
fibras em uma musculatura.
O objetivo deste estudo foi identificar as características dos sinais EMGs que sejam
capazes de distinguir, com maior precisão, diferentes proporções de tipos de fibras.
Também foi investigado a combinação de características por meio de modelos
matemáticos apropriados.
Para alcançar o objetivo proposto, sinais emulados foram desenvolvidos com diferentes
proporções de unidades motoras recrutadas e diferentes razões sinal-ruído.
Treze características no domínio do tempo e da frequência foram extraídas do sinais
emulados. Os resultados de cada característica extraída dos sinais emulados foram
submetidos ao algorítimo de agrupamento k-means para separar as diferentes proporções
de unidades motoras recrutadas nos sinais emulados. Técnicas matemáticas
(matriz confusão e técnica de capabilidade) foram implementadas para selecionar as
características capazes de identificar diferentes proporções de tipos de fibras musculares.
Como resultado, a frequência média e a frequência mediana foram selecionadas como capazes de distinguir com maior precisão as diferentes proporções de tipos de
fibras musculares.
Posteriormente, as características consideradas mais capazes foram analisadas
de forma associada por meio da análise de componentes principais. Foram encontradas
duas componentes principais para os sinais emulados sem ruído (CP1 e CP2) e
duas componentes principais para os sinais com ruído (CP1 e CP2 ), sendo as primeiras
componentes principais (CP1 e CP1 ) identificadas como capazes de distinguirem
diferentes proporções de fibras.
As características selecionadas (frequência mediana, frequência média, CP1 e
CP1 ) foram utilizadas para analisar sinais EMGs reais, comparando pessoas sedentárias
com pessoas fisicamente ativas praticantes de treinamentos físicos de força (musculação).
Os resultados obtidos com os diferentes grupos de voluntários mostram que
as pessoas fisicamente ativas obtiveram valores mais elevados de frequência média,
frequência mediana e componentes principais em comparação com as pessoas sedentárias.
Além disto, estes valores decaíram com o aumento do nível de força para
ambos os grupo, entretanto, o decaimento foi mais acentuado para o grupo de pessoas
fisicamente ativas. Com base nestes resultados, presume-se que os voluntários
do grupo fisicamente ativo apresentam maiores proporções de fibras do tipo II, se
comparado com as pessoas sedentárias.
Por fim, com base nos resultados obtidos, pode-se concluir que as características
selecionadas foram capazes de distinguir diferentes proporções de tipos de fibras
musculares, tanto para os sinais emulados quanto para os sinais reais. Estas características
podem ser utilizadas em vários estudos, como por exemplo, para avaliar a
evolução de pessoas com miopatias e neuromiopatia em decorrência da reabilitação
fisioterápica, e também para analisar o desenvolvimento de atletas que visam melhorar
sua capacidade muscular de acordo com sua modalidade esportiva. Em ambos
os casos, a extração destas características dos sinais de eletromiografia de superfície
proporciona um feedback ao fisioterapeuta e ao treinador físico, que podem analisar
o aumento na proporção de determinado tipo de fibra, conforme desejado em cada
caso. / Mestre em Ciências
|
Page generated in 0.13 seconds