11

[en] METHODOLOGY FOR EVALUATING THE CONTINUITY OF THE DISTRIBUTION SERVICE IN LOCATIONS WITH ACCESS RESTRICTIONS DUE TO RECORDS OF VIOLENCE / [pt] METODOLOGIA PARA AVALIAÇÃO DA CONTINUIDADE DO SERVIÇO DE DISTRIBUIÇÃO EM LOCAIS COM RESTRIÇÃO DE ACESSO POR REGISTROS DE VIOLÊNCIA

THAIS ROUPE BORGES 30 October 2023 (has links)
[pt] Os segmentos de geração, transmissão e distribuição constituem a cadeia produtiva do setor elétrico, sendo o consumidor ou carga o último elo que deve ser atendido pelas distribuidoras. A percepção de qualidade, e consequentemente a satisfação do cliente, está intrinsecamente relacionada, entre outros fatores, à continuidade do fornecimento assegurada pelas concessionárias. No Brasil, a Agência Nacional de Energia Elétrica (ANEEL) é responsável por regular o setor de distribuição e estabelecer indicadores de referência com o objetivo de avaliar a eficiência das concessionárias em termos de confiabilidade e qualidade do serviço prestado. Diversos fatores podem impactar a continuidade da distribuição de energia, sendo alguns mais conhecidos e gerenciáveis pelas empresas, como quedas de objetos na rede ou sobrecarga de equipamentos. No entanto, outros fatores, como restrições de acesso a determinadas áreas devido à violência e ao controle territorial por grupos criminosos, apresentam desafios complexos e de gerenciabilidade inexistente por parte das distribuidoras. Essas limitações dificultam a pronta recomposição do serviço em situações emergenciais, resultando em tempos de falha mais longos e afetando negativamente os indicadores de continuidade monitorados pela ANEEL, bem como a satisfação do consumidor. Neste contexto, a presente dissertação propõe uma metodologia focada em identificar os ativos da distribuidora localizados em áreas com evidências de violência, o que implica em acesso limitado pelas equipes de campo. É utilizada a base de dados geográfica da distribuidora (BDGD) para identificar as unidades transformadoras em áreas com evidências de violência, também delineadas por plataformas de dados públicos. Técnicas de clusterização e testes estatísticos são então utilizados para aferir se os índices de continuidade nessas áreas são significativamente diferentes e superiores aos de locais em que não se observa registros de violência. Sistemas de distribuição dos estados do Rio de Janeiro e Pernambuco são utilizados para testar a eficácia da metodologia proposta. Diversos testes são realizados e os resultados obtidos são plenamente discutidos. / [en] The segments of generation, transmission and distribution constitute the production chain of the electricity sector, with the consumer or load being the last link that must be served by the distributors. The perception of quality, and consequently customer satisfaction, is intrinsically related, among other factors, to the continuity of supply ensured by the concessionaires. In Brazil, the National Electric Energy Agency (ANEEL) is responsible for regulating the distribution sector and establishing benchmarks in order to assess the efficiency of concessionaires in terms of reliability and quality of service provided. Several factors can impact the continuity of energy distribution, some of which are better known and manageable by companies, such as falling objects on the network or overloading equipment. However, other factors, such as access restrictions to certain areas due to violence and territorial control by criminal groups, present complex challenges and non-existent manageability on the part of the distributors. These limitations make it difficult to promptly restore the service in emergency situations, resulting in longer failure durations and negatively affecting the continuity indicators monitored by ANEEL, as well as consumer satisfaction. In this context, this dissertation proposes a methodology focused on identifying the distributor s assets located in areas with evidence of violence, which implies limited access by field service teams. The distribution company s geographic database (BDGD) is used to identify transforming units in areas with evidence of violence, also delineated by public data platforms. Clustering techniques and statistical tests are then used to assess whether the continuity indices in these areas are significantly different and higher than those in places where there are no records of violence. Distribution systems in the states of Rio de Janeiro and Pernambuco are used to test the effectiveness of the proposed methodology. Several tests are carried out and the results obtained are fully discussed.
12

[en] DISTRIBUTED GENERATION IMPACT ON VOLTAGE STABILITY CONDITIONS / [pt] IMPACTO DA GERAÇÃO DISTRIBUÍDA NAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

FABIO BICALHO DE ARAUJO 10 June 2013 (has links)
[pt] Após a incidência de inúmeros colapsos de tensão em sistemas elétricos de potência por todo o mundo, a segurança de tensão tornou-se um assunto de extrema importância. O fenômeno de estabilidade de tensão deve-se à operação do sistema com carregamento elevado e se manifesta pela existência de uma máxima transferência de potência pela rede e ações de controle de tensão tendo efeito oposto ao usual. Com o aumento da inserção de geração distribuída, usualmente conectada à rede de distribuição existente e em tensões mais baixas, a possibilidade de ocorrência do fenômeno precisa ser investigada. É demonstrada a possibilidade de ocorrência em barras com geradores ou compensadores síncronos, onde a máxima potência gerada poderia estar limitada e o controle de tensão poderia ter o efeito oposto ao esperado. É apresentado o ferramental utilizado na avaliação das condições de estabilidade de tensão composto de índices com significado físico e matemático. Estabeleceu-se um procedimento para realizar simulações nos sistemas-teste IEEE 34 Barras e 70 Barras. É analisado o impacto do gerador nas condições de estabilidade de tensão, no perfil de tensão em regime permanente e nas perdas de potência ativa. Concluiu-se que, nos testes realizados, a injeção de potência ativa pelo gerador foi limitada por tensões fora da faixa permitida e não por problemas de estabilidade de tensão. / [en] After several incidence of voltage collapse in electric power systems around the world, the voltage security has become a matter of utmost importance. The phenomenon of voltage stability is due to the operation of the system with high loading and is manifested by the existence of a maximum power transfer over the network and efforts to control voltage having the opposite effect than usual. With increased integration of distributed generation, usually connected to the existing distribution network at lower voltages, the possibility of occurrence of the phenomenon should be investigated. It is demonstrated the possibility of occurrence in buses of synchronous generators or synchronous condensers, where the maximum generated power could be limited and the voltage control could have the opposite effect. It presented the tools used in assessing the conditions of voltage stability composite indexes with physical and mathematical meaning. I was established a procedure for performing simulations on IEEE 34 bus and 70 bus test systems. It analyzed the impact of the generator under the conditions of voltage stability, voltage profile in the steady state and the power losses. It was concluded that, in tests, the injection of active power from the generator was limited by voltage out of range allowed and not by voltage stability problems.