Spelling suggestions: "subject:"soil aquifer treatment"" "subject:"oil aquifer treatment""
11 |
Evaluation of Soil Aquifer Treatment in a Lab Scale Soil Column ExperimentPradhan, Prarthana 12 December 2018 (has links)
Soil aquifer treatment (SAT) during managed aquifer recharge has been studied as a method of providing additional environmental barriers to pathogens and contaminants in indirect potable reuse (IPR) applications. A soil column study was conducted by Hampton Roads Sanitation District in order to evaluate the effectiveness of SAT, as a component of its IPR project involving the replenishment of the Potomac Aquifer System (PAS), in providing a sustainable source of drinking water. Four packed soil columns were constructed with sand from the PAS and were designed to simulate the travel time of 3 days and 30 days. The tests conducted aimed at evaluating pathogen removal (MS2, E. coli and Cryptosporidium oocysts); evaluating attenuation of regulated (nitrate, nitrite, bromate, trihalomethane (THM), haloacetic acids (HAA), organic carbon) and unregulated contaminants of concern that affect drinking water quality. Effective pathogen removal was observed with 6 to 7-log removals of MS2 and E. coli and 3 to 5-log removals of microbeads, used as a surrogate for Cryptosporidium. Removal across 3 day columns was comparable to 30-day columns but the potential to achieve higher removal with longer retention time was acknowledged. Nitrate, bromate, THMs and HAAs were completely reduced in 30-day columns. Total organic carbon was removed at 25 – 35% in all four columns. Seven out of the 106 contaminants of emerging concern (CEC) tested were consistently detected in the column feed and effluent at concentrations greater than 100 ng/L; some compounds showed potential for removal while no conclusive results were drawn for the remaining compounds. / MS / Potable reuse is a sustainable solution to the increasing water demands of the present and more so the future. Hampton Road Sanitation District (HRSD) aims to treat effluent from its wastewater treatment plants using advanced treatment process for direct recharge of the Potomac aquifer system. This is a method of indirect potable reuse termed as managed aquifer recharge (MAR). MAR can provide additional environmental barriers to contaminants present in water through a process of natural attenuation called soil aquifer treatment (SAT). A soil column study was conducted at HRSD’s pilot scale facility in order to asses SAT under controlled conditions at a meaningful scale. Attenuation of pathogens; regulated contaminants (nitrate, nitrite, bromate, etc.) and contaminants of emerging concern was evaluated through the soil columns. The results showed effective removal of most contaminants of interest which demonstrated that SAT potentially improves water quality and meets public health standards in potable reuse applications.
|
12 |
Optimizing Managed Aquifer Recharge (MAR) Systems for Removal of Trace Organic Chemicals (TOrCs)Alidina, Mazahirali 06 1900 (has links)
Managed aquifer recharge (MAR) is a low-energy subsurface water treatment system with the potential of being an important component of sustainable water reuse schemes. Alongside common wastewater contaminants, MAR systems have been shown to attenuate a range of trace organic chemicals (TOrCs). Despite several factors being possibly important for TOrC attenuation, many have not been investigated in depth. This research effort investigated three factors affecting attenuation of the moderately degradable TOrCs: primary substrate, adaptation of the microbial community to presence of TOrCs, and groundwater temperature. The overall goal was to optimize TOrC attenuation using different MAR configurations considering how these factors affect TOrC attenuation.
The primary substrate composition and concentration significantly impacted attenuation of the moderately degradable TOrCs. Lower primary substrate concentrations and more refractory carbon generally resulted in better TOrC transformation, a more diverse microbial community in the infiltration zone and more diverse capabilities for TOrC degradation. The enzyme group cytochrome P450 may be important for TOrC transformation since its genes were more abundant under carbon-starving primary substrate conditions. Adaptation of the microbial community by pre-exposure to TOrCs was not required in order to degrade them. However, adaptation to the primary substrate was necessary for TOrC biotransformation due to its effect on the microbial community. Attenuation of most TOrCs was unaffected by changes in temperature. Some moderately degradable TOrCs, however, were better attenuated at higher temperatures likely due to increased microbial activity. Others were better degraded at lower temperatures likely due to favorable sorption conditions.
In the context of applying MAR systems to potential water reuse schemes within Saudi Arabia, a reconnaissance study of TOrC occurrence in treated wastewater effluents was undertaken. Most of the TOrCs targeted were detected at similar concentrations to US effluents at comparable plants. One of the plants studied, however, displayed a significantly different TOrC footprint from the other treatment plants due to the large number of international visitors in its sewershed. Findings from this occurrence study as well from other tasks provided inputs to a risk assessment framework to compare the effectiveness of MAR systems as part of a multiple-barrier water reuse scheme.
|
13 |
Effects of Experimental Scale on the Adsorption of Two Pharmaceutical Drugs Detected in Municipal Wastewater EffluentMoore, Michael 01 June 2022 (has links) (PDF)
Pharmaceutical drugs are being produced and consumed in increasing quantities every year and are poorly treated by conventional wastewater treatment processes, leading to increasing detection of such compounds in surface water, groundwater, and municipal drinking water. Soil aquifer treatment (SAT) is a promising method for treating these emerging compounds through combined adsorption and degradation of target compounds in soil. This thesis examines the consistency of results from typical studies like adsorption isotherms and soil columns utilized in analysis of SAT performance, across varying experimental scales. The adsorption behavior of two pharmaceuticals was investigated as a function of experimental scale and soil organic content in adsorbent media. This thesis shows that broad trends in pharmaceutical adsorption are not dependent upon experimental scale. Across adsorption isotherm, bench-scale soil column, and large-scale soil column experiments, adsorption and of both drugs was greater in organic soil than inorganic soil, although dispersive transport may have increased in some experiments. Across all experiments, carbamazepine was adsorbed by soils more than diclofenac. Some inconsistencies were observed across scales between the two organic soils, a mediumorganic and high-organic soil, where adsorption was generally greater in high organic soil, but sometimes observed to be greater in medium organic soil. This may suggest that the decrease of experimental control resulting from increased experimental scale obfuscates more nuanced relationships in SAT experimental conditions. Broad trends in data showing whether or not a soil displayed significant adsorptive behavior and which pharmaceutical was adsorbed more were consistent. However, the degree of partitioning via adsorption varied across scales as experimental control decreased with increasing physical scale.
|
14 |
Efficiency of soil aquifer treatment in the removal of wastewater contaminants and endocrine disruptors : a study on the removal of triclocarban and estrogens and the effect of chemical oxygen demand and hydraulic loading rates on the reduction of organics and nutrients in the unsaturated and saturated zones of the aquiferEssandoh, Helen Michelle Korkor January 2011 (has links)
This study was carried out to evaluate the performance of Soil Aquifer Treatment (SAT) under different loading regimes, using wastewater of much higher strength than usually encountered in SAT systems, and also to investigate the removal of the endocrine disruptors triclocarban (TCC), estrone (E1), 17β-estradiol (E2) and 17α-ethinylestradiol (EE2). SAT was simulated in the laboratory using a series of soil columns under saturated and unsaturated conditions. Investigation of the removal of Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Dissolved Organic Carbon (DOC), nitrogen and phosphate in a 2 meter long saturated soil column under a combination of constant hydraulic loading rates (HLRs) and variable COD concentrations as well as variable HLR under constant COD showed that at fixed HLR, a decrease in the influent concentrations of DOC, BOD, total nitrogen and phosphate improved their removal efficiencies. It was found that COD mass loading applied as low COD wastewater infiltrated over short residence times would provide better effluent quality than the same mass applied as a COD with higher concentration at long residence times. On the other hand relatively high concentrations coupled with long residence time gave better removal efficiency for organic nitrogen. Phosphate removal though poor under all experimental conditions, was better at low HLRs. In 1 meter saturated and unsaturated soil columns, E2 was the most easily removed estrogen, while EE2 was the least removed. Reducing the thickness of the unsaturated zone had a negative impact on removal efficiencies of the estrogens whereas increased DOC improved the removal in the saturated columns. Better removal efficiencies were also obtained at lower HLRs and in the presence of silt and clay. Sorption and biodegradation were found to be responsible for TCC removal in a 300 mm long saturated soil column, the latter mechanism however being unsustainable. TCC removal efficiency was dependent on the applied concentration and decreased over time and increased with column depth. Within the duration of the experimental run, TCC negatively impacted on treatment performance, possibly due to its antibacterial property, as evidenced by a reduction in COD removals in the column. COD in the 2 meter column under saturated conditions was modelled successfully with the advection dispersion equation with coupled Monod kinetics. Empirical models were also developed for the removal of TCC and EE2 under saturated and unsaturated conditions respectively. The empirical models predicted the TCC and EE2 removal profiles well. There is however the need for validation of the models developed
|
15 |
Efficiency of soil aquifer treatment in the removal of wastewater contaminants and endocrine disruptors. A study on the removal of triclocarban and estrogens and the effect of chemical oxygen demand and hydraulic loading rates on the reduction of organics and nutrients in the unsaturated and saturated zones of the aquifer.Essandoh, Helen M.K. January 2011 (has links)
This study was carried out to evaluate the performance of Soil Aquifer Treatment
(SAT) under different loading regimes, using wastewater of much higher strength
than usually encountered in SAT systems, and also to investigate the removal of the
endocrine disruptors triclocarban (TCC), estrone (E1), 17¿-estradiol (E2) and 17¿-
ethinylestradiol (EE2). SAT was simulated in the laboratory using a series of soil
columns under saturated and unsaturated conditions.
Investigation of the removal of Chemical Oxygen Demand (COD), Biochemical
Oxygen Demand (BOD), Dissolved Organic Carbon (DOC), nitrogen and phosphate
in a 2 meter long saturated soil column under a combination of constant hydraulic
loading rates (HLRs) and variable COD concentrations as well as variable HLR
under constant COD showed that at fixed HLR, a decrease in the influent
concentrations of DOC, BOD, total nitrogen and phosphate improved their removal
efficiencies. It was found that COD mass loading applied as low COD wastewater
infiltrated over short residence times would provide better effluent quality than the
same mass applied as a COD with higher concentration at long residence times. On
the other hand relatively high concentrations coupled with long residence time gave
better removal efficiency for organic nitrogen. Phosphate removal though poor under
all experimental conditions, was better at low HLRs.
In 1 meter saturated and unsaturated soil columns, E2 was the most easily removed
estrogen, while EE2 was the least removed. Reducing the thickness of the
unsaturated zone had a negative impact on removal efficiencies of the estrogens
whereas increased DOC improved the removal in the saturated columns. Better
removal efficiencies were also obtained at lower HLRs and in the presence of silt
and clay.
Sorption and biodegradation were found to be responsible for TCC removal in a 300
mm long saturated soil column, the latter mechanism however being unsustainable.
TCC removal efficiency was dependent on the applied concentration and decreased
over time and increased with column depth. Within the duration of the experimental
run, TCC negatively impacted on treatment performance, possibly due to its
antibacterial property, as evidenced by a reduction in COD removals in the column.
COD in the 2 meter column under saturated conditions was modelled successfully
with the advection dispersion equation with coupled Monod kinetics. Empirical
models were also developed for the removal of TCC and EE2 under saturated and
unsaturated conditions respectively. The empirical models predicted the TCC and
EE2 removal profiles well. There is however the need for validation of the models
developed / Netherlands Organisation for International Cooperation in Higher Education (Nuffic) / The Appendix files for this thesis are unavailable online via Bradford Scholars.
|
16 |
Recarga gerenciada do aqüífero do Aeroporto Internacional Governador André Franco Montoro, Guarulhos/SP: estudo piloto do sistema solo-aqüífero. / Managed aquifer recharge of the Governor André Franco Montoro International Airport, Guarulhos/SP: pilot study of soil-aquifer system.Okpala, Walter Onyebuchi 15 February 2011 (has links)
O Aeroporto Internacional Governador André Franco Montoro (GRU), São Paulo, depende inteiramente da água subterrânea para suprir sua demanda. Entretanto, a prática de extração excessiva, que aumenta continuamente para atender à demanda de um número cada vez maior de passageiros e às dificuldades envolvidas com a recarga natural do aqüífero, levou a Empresa Brasileira de Infraestrutura Aeroportuária (Infraero) a procurar outras fontes de abastecimento. Embora a busca de solução para o problema da escassez da água, passe pela opção de recarga gerenciada do aqüífero, a falta da experiência nacional nessa área restringe a tomada da decisão na adoção dessa prática no país. Objetivando contribuir com estudos de viabilidade técnica da recarga gerenciada de aqüíferos em geral e, em particular, do Aeroporto Internacional Governador André Franco Montoro, este trabalho tem o objetivo de verificar, em escala piloto, a capacidade do solo-aqüífero do aeroporto em tratar adequadamente o esgoto gerado localmente. Para atingir esse objetivo, uma área adequada foi selecionada entre as diversas avaliadas, para a construção de uma unidade piloto de recarga de aqüífero. No local selecionado, amostras indeformadas da camada não saturada foram coletadas, caracterizadas e, posteriormente, montadas em colunas experimentais especiais, pelas quais o esgoto foi infiltrado de maneira controlada. Como os resultados desta primeira fase experimental não foram adequadamente atendidos, foi decidido efetuar coletas de amostras indeformadas em uma segunda área do aeroporto, que indicou a existência de uma camada vadosa mais profunda, mas perfil de solo semelhante ao perfil anterior. Os ensaios de colunas foram efetuados com amostras de ambas as áreas, indicando que o solo superficial do aeroporto deverá ser eliminado, ou substituído por uma camada de areia grossa para permitir uma recarga gerenciada que permita a produção de águas com qualidade adequada para os usos preconizados. Os diferentes cenários utilizados nesta pesquisa envolveram a infiltração nas colunas de recarga com esgotos secundários produzidos no aeroporto, após passagem por duas lagoas de retenção, a infiltração do mesmo efluente tratado por um processo físico-químico de coagulação/floculação/sedimentação e pelo mesmo efluente das lagoas de retenção após tratamento por um sistema de membranas de ultrafiltração. Os resultados obtidos são considerados como resultados parciais, uma vez que toda a profundidade do aqüífero não foi utilizada e pelo fato de que, face às restrições acadêmicas vigentes o tempo disponível para a realização da pesquisa foi extremamente restringido. Entretanto, considera-se este trabalho como pioneiro, pelo fato dele se constituir na primeira pesquisa sobre recarga gerenciada no Brasil e, ainda, por fornecer subsídios teóricos e práticos para suportar outros estudos semelhantes que se farão necessários para compreender e promover a prática de recarga gerenciada de aqüíferos no Brasil. / The Governor André Franco Montoro International Airport, São Paulo, entirely depends on groundwater to meet its demand. However, excessive extraction practice which increase continuously in order to attend the demand of increasing number of passengers and the difficulty involved with natural recharge of its aquifer led the Federal Airport Administration Agency (Infraero) to search for other sources of water supply. Although the search for solution for water scarcity problem goes through managed aquifer recharge, lack of national experience in this area restricts decision making in adopting this practice in the country. Contributing to the technical feasibility studies of managed aquifer recharge in general and the Governor André Franco Montoro International Airport in particular, this research has the objective of verifying at the pilot scale level, the capacity of airport soil-aquifer in adequately treating wastewater generated locally. In order to reach this objective, an adequate location was selected within the alternatives evaluated for the construction of a pilot unit for aquifer recharge. Undeformed samples were collected from the unsaturated layer of the selected place, characterized and afterwards, recharged through special experimental columns with wastewater which was filtered in a controlled form. As the results of the first experimental phase were not adequately met, a decision was made to collect undeformed samples from a second location in the airport. The collection indicated the existence of deep unsaturated layer with the soil profile being similar to the profile of the soil layer from which the first samples were collected. The soil column tests were carried out with samples from both areas, indicating that superficial part of airport soil will be eliminated or substituted with a coarse sandy layer in order to permit a managed aquifer recharge which allows production of water that meets the quality of its required uses. Of the different scenarios verified in this research was infiltration of secondary wastewater produced at the airport through soil columns. Another was infiltration of wastewater after its pre-treatment by physicalchemical processes of coagulation/flocculation/sedimentation and still a third scenario, through pre-treatment of secondary effluent by ultrafiltration membrane. The results obtained are considered partial since the total aquifer depth was not used and the fact that academic restrictions limited excessively the time period of the research. However, considering this as a pioneer work, and the fact that it constitutes the first research about managed aquifer recharge in Brazil, and with it, bringing theoretical and practical contributions to support other similar studies which would be necessary in understanding and promoting managed aquifer recharge practice in Brazil.
|
17 |
Recarga gerenciada do aqüífero do Aeroporto Internacional Governador André Franco Montoro, Guarulhos/SP: estudo piloto do sistema solo-aqüífero. / Managed aquifer recharge of the Governor André Franco Montoro International Airport, Guarulhos/SP: pilot study of soil-aquifer system.Walter Onyebuchi Okpala 15 February 2011 (has links)
O Aeroporto Internacional Governador André Franco Montoro (GRU), São Paulo, depende inteiramente da água subterrânea para suprir sua demanda. Entretanto, a prática de extração excessiva, que aumenta continuamente para atender à demanda de um número cada vez maior de passageiros e às dificuldades envolvidas com a recarga natural do aqüífero, levou a Empresa Brasileira de Infraestrutura Aeroportuária (Infraero) a procurar outras fontes de abastecimento. Embora a busca de solução para o problema da escassez da água, passe pela opção de recarga gerenciada do aqüífero, a falta da experiência nacional nessa área restringe a tomada da decisão na adoção dessa prática no país. Objetivando contribuir com estudos de viabilidade técnica da recarga gerenciada de aqüíferos em geral e, em particular, do Aeroporto Internacional Governador André Franco Montoro, este trabalho tem o objetivo de verificar, em escala piloto, a capacidade do solo-aqüífero do aeroporto em tratar adequadamente o esgoto gerado localmente. Para atingir esse objetivo, uma área adequada foi selecionada entre as diversas avaliadas, para a construção de uma unidade piloto de recarga de aqüífero. No local selecionado, amostras indeformadas da camada não saturada foram coletadas, caracterizadas e, posteriormente, montadas em colunas experimentais especiais, pelas quais o esgoto foi infiltrado de maneira controlada. Como os resultados desta primeira fase experimental não foram adequadamente atendidos, foi decidido efetuar coletas de amostras indeformadas em uma segunda área do aeroporto, que indicou a existência de uma camada vadosa mais profunda, mas perfil de solo semelhante ao perfil anterior. Os ensaios de colunas foram efetuados com amostras de ambas as áreas, indicando que o solo superficial do aeroporto deverá ser eliminado, ou substituído por uma camada de areia grossa para permitir uma recarga gerenciada que permita a produção de águas com qualidade adequada para os usos preconizados. Os diferentes cenários utilizados nesta pesquisa envolveram a infiltração nas colunas de recarga com esgotos secundários produzidos no aeroporto, após passagem por duas lagoas de retenção, a infiltração do mesmo efluente tratado por um processo físico-químico de coagulação/floculação/sedimentação e pelo mesmo efluente das lagoas de retenção após tratamento por um sistema de membranas de ultrafiltração. Os resultados obtidos são considerados como resultados parciais, uma vez que toda a profundidade do aqüífero não foi utilizada e pelo fato de que, face às restrições acadêmicas vigentes o tempo disponível para a realização da pesquisa foi extremamente restringido. Entretanto, considera-se este trabalho como pioneiro, pelo fato dele se constituir na primeira pesquisa sobre recarga gerenciada no Brasil e, ainda, por fornecer subsídios teóricos e práticos para suportar outros estudos semelhantes que se farão necessários para compreender e promover a prática de recarga gerenciada de aqüíferos no Brasil. / The Governor André Franco Montoro International Airport, São Paulo, entirely depends on groundwater to meet its demand. However, excessive extraction practice which increase continuously in order to attend the demand of increasing number of passengers and the difficulty involved with natural recharge of its aquifer led the Federal Airport Administration Agency (Infraero) to search for other sources of water supply. Although the search for solution for water scarcity problem goes through managed aquifer recharge, lack of national experience in this area restricts decision making in adopting this practice in the country. Contributing to the technical feasibility studies of managed aquifer recharge in general and the Governor André Franco Montoro International Airport in particular, this research has the objective of verifying at the pilot scale level, the capacity of airport soil-aquifer in adequately treating wastewater generated locally. In order to reach this objective, an adequate location was selected within the alternatives evaluated for the construction of a pilot unit for aquifer recharge. Undeformed samples were collected from the unsaturated layer of the selected place, characterized and afterwards, recharged through special experimental columns with wastewater which was filtered in a controlled form. As the results of the first experimental phase were not adequately met, a decision was made to collect undeformed samples from a second location in the airport. The collection indicated the existence of deep unsaturated layer with the soil profile being similar to the profile of the soil layer from which the first samples were collected. The soil column tests were carried out with samples from both areas, indicating that superficial part of airport soil will be eliminated or substituted with a coarse sandy layer in order to permit a managed aquifer recharge which allows production of water that meets the quality of its required uses. Of the different scenarios verified in this research was infiltration of secondary wastewater produced at the airport through soil columns. Another was infiltration of wastewater after its pre-treatment by physicalchemical processes of coagulation/flocculation/sedimentation and still a third scenario, through pre-treatment of secondary effluent by ultrafiltration membrane. The results obtained are considered partial since the total aquifer depth was not used and the fact that academic restrictions limited excessively the time period of the research. However, considering this as a pioneer work, and the fact that it constitutes the first research about managed aquifer recharge in Brazil, and with it, bringing theoretical and practical contributions to support other similar studies which would be necessary in understanding and promoting managed aquifer recharge practice in Brazil.
|
18 |
Soil aquifer treatment of artificial wastewater under saturated conditionsEssandoh, Helen M.K., Tizaoui, Chedly, Mohamed, Mostafa H.A., Amy, G., Brdjanovic, D. January 2011 (has links)
A 2000 mm long saturated laboratory soil column was used to simulate soil aquifer treatment under saturated conditions to assess the removal of chemical and biochemical oxygen demand (COD and BOD), dissolved organic carbon (DOC), nitrogen and phosphate, using high strength artificial wastewater. The removal rates were determined under a combination of constant hydraulic loading rates (HLR) and variable COD concentrations as well as variable HLR under a constant COD. Within the range of COD concentrations considered (42 mg L(-)(1)-135 mg L(-)(1)) it was found that at fixed hydraulic loading rate, a decrease in the influent concentrations of dissolved organic carbon (DOC), biochemical oxygen demand (BOD), total nitrogen and phosphate improved their removal efficiencies. At the high COD concentrations applied residence times influenced the redox conditions in the soil column. Long residence times were detrimental to the removal process for COD, BOD and DOC as anoxic processes and sulphate reduction played an important role as electron acceptors. It was found that total COD mass loading within the range of 911 mg d(-)(1)-1780 mg d(-)(1) applied as low COD wastewater infiltrated coupled with short residence times would provide better effluent quality than the same mass applied as a COD with higher concentration at long residence times. The opposite was true for organic nitrogen where relatively high concentrations coupled with long residence time gave better removal efficiency.
|
19 |
Grundwasseranreicherung unter den geologischen, hydrochemischen und geografischen Bedingungen des Distrito Federal, BrasilienGaffron, Anne 06 January 2015 (has links) (PDF)
The Distrito Federal in Western Central Brazil is characterized by a high share of urban population and a predicted growth of population. The corresponding increasing water consumption is associated with a falling groundwater table. The existing wastewater treatment plants could reach their capacity limits due to further increasing amounts of urban wastewater in conjunction with heavy precipitation events. During these events, untreated wastewater can become a contamination source for protected resources such as soil and water. This problem can be solved by soil aquifer recharge. This is a unique technique to take the load off the treatment plants, to store the water in the aquifer, and to improve the water quality during the soil passage. The controlled infiltration of pretreated municipal wastewater in the tropical soils can ensure the regional groundwater balance and backup high quality water as a suitable drinking water resource.
The objective of the present thesis was to define suitable soils and areas for a soil aquifer treatment in the Distrito Federal to support the decentralized wastewater treatment management. For the identification of suitable soils, representative samples were taken. The soil samples were examined with respect to their pedological and geochemical properties. For the characterization of the unsaturated hydraulic conditions, in situ infiltration tests and a 3D infiltration monitoring were performed. Additionally, the retention potentials for sewage ingredients were determined for each soil with unsaturated, hydrochemical and geoelectrical column tests. Thus, it was possible to calculate the retention potentials of each soil against the wastewater content of an artificial wastewater.
The artificial wastewater with known composition was infiltrated through the soil columns. The retention potentials of the soils were calculated by balancing the hydrochemical data. Afterwards, for the implementation of the hydraulic data and the data from the column tests, a utility analysis was performed to merge all parameters. Finally, the field and laboratory studies were combined within a GIS-based usability analysis to blend the determined parameter with geo-data to identify suitable areas for a soil aquifer treatment. Parameters as slope, land use and land cover were included in this analysis.
After the evaluation of the hydrochemical balances, predominantly the younger soils turn out as suitable for an artificial recharge with water of impaired quality because of their high retention potential for TOC. The Gleissolo featured a retention potential of almost 100 % for TOC. However, a high hydraulic conductivity in the soils is necessary to ensure an effective artificial recharge. The Gleissolo featured the lowest measured hydraulic conductivity in the field test with 1,12 x 10-8 m/s. Due to the consideration of the determined hydraulic and hydrochemical data in the utility analysis, each parameter was weighted to embrace the requirement of an effective artificial recharge.
The results of the laboratory and field tests have shown that the soil group of Latossolos is suitable for a soil aquifer treatment. These soils offer the best infiltration characteristics and a good retention potential against sewage ingredients for an effective artificial groundwater recharge with pretreated wastewater. Additional to that, slope, land use/land cover, depth of soil, and a defined distance to conservation area were considered in a GIS-based usability analysis. Additionally, the categorized soils from the utility analysis were included to identify suitable regions.
The outcome of the thesis is a GIS-based usability analysis map which shows suitable areas for a soil aquifer treatment ranked by their category of suitability. Additionally, the thesis provides crucial evidences for soil parameters which have positive effects on wastewater infiltration. In addition, the 3D infiltration monitoring and the measured resistivity distribution showed that the gravitatively controlled infiltration influences only the soil zone immediately beneath the irrigation. Furthermore, it was found that the proxy of the geoelectrical resistivity is not (sufficiently) conclusive for the sorption potential of conductive wastewater ingredients. / O Distrito Federal, localizado no Centro-Oeste Brasileiro, é caracterizado por um intenso processo de urbanização o qual deve aumentar ainda mais nas próximas décadas. O correspondente crescimento no consumo de água está, também, associado ao rebaixamento dos níveis das águas subterrâneas. O atual sistema de tratamento de efluentes pode atingir seu limite de operação diante do crescimento demográfico e aumento de eventos extremos de chuva. Durante esses eventos, efluentes não tratados podem tornar-se uma fonte de contaminação aos recursos hídricos e solos. Uma solução é recarga artificial de águas subterrâneas. A mesma armazena o efluente pré-tratado nas águas subterrâneas e melhora a qualidade do mesmo durante o processo de percolação no solo. A infiltração controlada em solos tropicais pode contribuir para a qualidade das águas subterrâneas e balanço hídrico, servindo assim como fonte para o abastecimento de água.
Essa tese tem como objetivo a identificação de áreas e solos propícios à recarga artificial de águas subterrâneas no Distrito Federal a fim de dar suporte à gestão decentralizada de tratamento de efluentes. Para a identificação dessas áreas, amostras representativas à diferentes tipos de solos foram obtidas. As amostras foram examinadas de acordo com suas propriedades pedológicas e geoquímicas. Para a caracterização das condições hidráulicas não saturadas, realizaram-se diversos testes de infiltração in situ, bem como o monitoramento 3D. Ainda, determinou-se para cada solo o potencial de retenção de poluentes através de testes de coluna insaturados, hidroquímico e geoelétricos. Dessa forma foi possível calcular os potenciais de retenção para cada solo quando utilizados efluentes sintéticos.
Com base na contabilização de todos os dados hidroquímicos, calculou-se os potenciais de retenção de poluentes para o determinado efluente de composição conhecida. Mais a frente, para a implementação de dados hidráulicos e dados dos testes de coluna, utilizou-se uma análise de utilidade considerando todos os parâmetros. Finalmente, estudos de laboratório e campo foram combinados em uma análise baseada em sistema de informação geográfica (SIG). O mesmo permite o cruzamento de um determinado parâmetro obtido com uma base de dados georeferenciados (p. ex. classes de solos) a fim de identificar as áreas mais propícias. Parâmetros tais como declividade, uso e cobertura de solo foram incluídos nessa análise.
Após a avaliação dos balanços hidroquímicos, identificou-se que os solos jovens possuem um alto potencial de retenção de carbono orgânico total (COT). Os mesmos mostraram-se adequados para recarga de águas subterrâneas com efluente residuário pré-tratado. Como exemplo, o Gleisolo apresentou um potencial de retenção de aproximadamente 100% de COT. No entanto, é importante lembrar que, a fim de garantir uma retenção efetiva, a condutividade hidráulica do solo deve ser alta. Nesse caso, o Gleisolo apresentou baixos valores no teste de campo com uma condutividade hidráulica de 1,12 x 10-8 m/s.
Ainda, os dados hidráulicos e hidroquímicos medidos foram integrados à uma análise de uso-benefício. No caso, cada parâmetro recebe um peso de modo a atender às demandas de uma recarga efetiva de águas subterrâneas.
Resultados mostram que o grupo de solo classificado com Latossolo é propício para a recarga de águas subterrâneas. O mesmo oferece a melhor característica de infiltração e potencial de retenção de contaminantes para uma recarga artificial com efluentes pré-tratados. Declividade, uso e ocupação de solo, profundidade do solo e uma distância devida de áreas de conservação foram contemplados na análise de utilidade baseada em SIG. Além disso, os colos caracterizados pela análise de uso-benefício foram incluídos com o intuito de identificar as regiões mais propícias para a prática.
O resultado da tese é uma representação gráfica georeferenciada das áreas propícias para a aplicação de recarga artificial de águas subterrâneas. Ainda, a tese fornece evidências cruciais de parâmetros do solo que tem efeitos positivos na infiltração de efluentes pré-tratados. O monitoramento 3D de infiltração e a distribuição de resistividade medida mostram que infiltração controlada por gravidade influencia apenas a zona do solo imediata à superfície de irrigação. Mas a frente, foi determinado que o proxy da resistividade geoelétrica não é válido para o potencial de retenção de contaminantes condutores. / Der Distrito Federal ist durch eine starke Urbanisierung geprägt. Das ohnehin bereits starke Bevölkerungswachstum wird Prognosen zufolge weiter zunehmen. Der damit verbundene Anstieg des Wasserverbrauchs wird auch in absinkenden Grundwasserständen widergespiegelt. Weiterhin ist das westliche Zentralbrasilien aufgrund seiner Lage in den wechselfeuchten Tropen durch eine starke Saisonalität der Niederschläge geprägt. Das erhöhte Abwasseraufkommen in Verbindung mit extremen Niederschlagsereignissen kann zu einer deutlichen Überbelastung der vorhandenen Kläranlagen führen. In Extremsituationen kann ungeklärtes Abwasser in die Bodenzone gelangen und somit Schutzgüter wie Boden und Wasser kontaminieren. Eine effiziente Maßnahme gegenüber der unkontrollierten Versickerung von ungeklärtem Abwasser sowie zur Vorbeugung absinkender Grundwasserspiegel ist die gezielte Infiltration von vorbehandeltem Abwasser in Verbindung mit einer Grundwasseranreicherung. Diese Maßnahme umfasst einen zusätzlichen Reinigungsschritt des vorgereinigten Abwassers und dient zur Vorbeugung gegenüber absinkenden Grundwasserspiegeln.
Ziel der Arbeit war es, geeignete Böden und Flächen für eine Grundwasseranreicherung mit vorbehandeltem Abwasser im Distrito Federal auszuweisen. Zur Identifizierung geeigneter Böden wurden repräsentative Bodenproben auf ihre pedologischen und geochemischen Eigenschaften hin untersucht.
Zusätzlich wurden in situ Durchlässigkeitstests und ein Versickerungsmonitoring aufgebaut, um zur Klärung der Infiltrationseigenschaften beizutragen. Für die Laboruntersuchungen wurden die Bodenproben im Hinblick auf ihre Schadstoffrückhaltepotentiale untersucht. Dazu wurden kombinierte hydrochemische und geoelektrische sowie ungesättigte Säulenversuche durchgeführt. Dadurch war es möglich, Rückschlüsse auf die Sorptionsleistung der Böden gegenüber den Abwasserinhaltsstoffen einer künstlichen Abwasserlösung schließen zu können. Die Bodensäulen wurden mit einem künstlichen Abwasser mit bekannter Schadstoffzusammensetzung überstaut.
Auf der Grundlage der Bilanzierung aller hydrochemischen Daten wurden die Schadstoffrückhaltepotentiale für die Abwasserinhaltsstoffe berechnet. Anschließend wurden die experimentell ermittelten Parameter in einer Nutzwertanalyse zusammengefasst, um so geeignete Böden für eine effiziente Grundwasseranreicherung mit vorbehandeltem Abwasser zu identifizieren. Abschließend wurden die Feld- und Laboruntersuchungen mit einer GIS-basierten Nutzbarkeitsanalyse komplettiert, um die gemessenen Parameter mit weiteren vorliegenden, räumlich aufgelösten Daten verschneiden zu können. In diese Analyse wurden Parameter wie Gefälle, Landnutzung und Landbedeckung einbezogen.
Bei der Auswertung der hydrochemischen Bilanzen kristallisierten sich vorwiegend die jungen Böden aufgrund ihrer hohen Schadstoffrückhaltepotentiale als geeignete Böden für eine Grundwasseranreicherung mit vorbehandeltem Abwasser heraus. Exemplarisch wies der Gleissolo ein Sorptionspotential von fast 100 % für den Parameter TOC auf. Allerdings müssen Böden für eine effektive Grundwasseranreicherung mit vorbehandeltem Abwasser zusätzlich zu den hohen Sorptionsleistungen auch hohe hydraulische Durchlässigkeiten aufweisen. Für den Gleissolo wurde im Feldversuch die niedrigste hydraulische Durchlässigkeit von 1,12 x 10-8 m/s bestimmt. Durch die Einbindung der gemessenen hydraulischen und hydrochemischen Daten in eine Nutzwertanalyse konnten diese Parameter gewichtet werden, um so den Ansprüchen einer effektiven Grundwasseranreicherung gerecht zu werden.
Im Ergebnis der durchgeführten Untersuchungen hat sich gezeigt, dass sich die Bodengruppe der Latossole besonders gut für eine Grundwasseranreicherung mit vorbehandeltem Abwasser eignet. Diese Böden weisen die besten Infiltrationsbedingungen sowie gute Sorptionseigenschaften für eine effizient gestaltete Grundwasseranreicherung auf. Mit Hilfe der GIS-basierten Nutzbarkeitsanalyse geografischer Parameter wurden Flächen ausgezeichnet, die sich in Bezug auf Gefälle, Landnutzung/Landbedeckung, Bodentiefe und einer adäquaten Distanz zu Schutzgebieten für eine Grundwasseranreicherung mit vorbehandeltem Abwasser eignen.
Zusätzlich wurden die mit Hilfe der Nutzwertanalyse kategorisierten Böden in die Flächenidentifizierung einbezogen. Das Resultat dieser Arbeit liegt in Form einer Karte vor, in der die Gebiete, die für eine Grundwasseranreicherung mit vorbehandeltem Abwasser geeignet sind, nach Kategorien geordnet, verzeichnet sind. Zusätzlich dazu liefert die Arbeit entscheidende Hinweise auf Bodeneigenschaften, die sich positiv auf eine Abwasserinfiltration auswirken. Darüber hinaus konnte durch das geoelektrische 3D-Monitoring und der dabei gemessenen Verteilung des spezifischen elektrischen Widerstandes gezeigt werden, dass die Infiltration gravitativ gesteuert nur die Bodenzone direkt unterhalb der Verrieselung beeinflusste. Weiterhin wurde festgestellt, dass das Proxy des geoelektrischen Widerstandes im Labormaßstab nicht aussagekräftig genug ist, um Rückschlüsse auf die Sorption leitfähigkeitsrelevanter Abwasserinhaltsstoffe geben zu können.
|
20 |
Grundwasseranreicherung unter den geologischen, hydrochemischen und geografischen Bedingungen des Distrito Federal, BrasilienGaffron, Anne 24 September 2014 (has links)
The Distrito Federal in Western Central Brazil is characterized by a high share of urban population and a predicted growth of population. The corresponding increasing water consumption is associated with a falling groundwater table. The existing wastewater treatment plants could reach their capacity limits due to further increasing amounts of urban wastewater in conjunction with heavy precipitation events. During these events, untreated wastewater can become a contamination source for protected resources such as soil and water. This problem can be solved by soil aquifer recharge. This is a unique technique to take the load off the treatment plants, to store the water in the aquifer, and to improve the water quality during the soil passage. The controlled infiltration of pretreated municipal wastewater in the tropical soils can ensure the regional groundwater balance and backup high quality water as a suitable drinking water resource.
The objective of the present thesis was to define suitable soils and areas for a soil aquifer treatment in the Distrito Federal to support the decentralized wastewater treatment management. For the identification of suitable soils, representative samples were taken. The soil samples were examined with respect to their pedological and geochemical properties. For the characterization of the unsaturated hydraulic conditions, in situ infiltration tests and a 3D infiltration monitoring were performed. Additionally, the retention potentials for sewage ingredients were determined for each soil with unsaturated, hydrochemical and geoelectrical column tests. Thus, it was possible to calculate the retention potentials of each soil against the wastewater content of an artificial wastewater.
The artificial wastewater with known composition was infiltrated through the soil columns. The retention potentials of the soils were calculated by balancing the hydrochemical data. Afterwards, for the implementation of the hydraulic data and the data from the column tests, a utility analysis was performed to merge all parameters. Finally, the field and laboratory studies were combined within a GIS-based usability analysis to blend the determined parameter with geo-data to identify suitable areas for a soil aquifer treatment. Parameters as slope, land use and land cover were included in this analysis.
After the evaluation of the hydrochemical balances, predominantly the younger soils turn out as suitable for an artificial recharge with water of impaired quality because of their high retention potential for TOC. The Gleissolo featured a retention potential of almost 100 % for TOC. However, a high hydraulic conductivity in the soils is necessary to ensure an effective artificial recharge. The Gleissolo featured the lowest measured hydraulic conductivity in the field test with 1,12 x 10-8 m/s. Due to the consideration of the determined hydraulic and hydrochemical data in the utility analysis, each parameter was weighted to embrace the requirement of an effective artificial recharge.
The results of the laboratory and field tests have shown that the soil group of Latossolos is suitable for a soil aquifer treatment. These soils offer the best infiltration characteristics and a good retention potential against sewage ingredients for an effective artificial groundwater recharge with pretreated wastewater. Additional to that, slope, land use/land cover, depth of soil, and a defined distance to conservation area were considered in a GIS-based usability analysis. Additionally, the categorized soils from the utility analysis were included to identify suitable regions.
The outcome of the thesis is a GIS-based usability analysis map which shows suitable areas for a soil aquifer treatment ranked by their category of suitability. Additionally, the thesis provides crucial evidences for soil parameters which have positive effects on wastewater infiltration. In addition, the 3D infiltration monitoring and the measured resistivity distribution showed that the gravitatively controlled infiltration influences only the soil zone immediately beneath the irrigation. Furthermore, it was found that the proxy of the geoelectrical resistivity is not (sufficiently) conclusive for the sorption potential of conductive wastewater ingredients. / O Distrito Federal, localizado no Centro-Oeste Brasileiro, é caracterizado por um intenso processo de urbanização o qual deve aumentar ainda mais nas próximas décadas. O correspondente crescimento no consumo de água está, também, associado ao rebaixamento dos níveis das águas subterrâneas. O atual sistema de tratamento de efluentes pode atingir seu limite de operação diante do crescimento demográfico e aumento de eventos extremos de chuva. Durante esses eventos, efluentes não tratados podem tornar-se uma fonte de contaminação aos recursos hídricos e solos. Uma solução é recarga artificial de águas subterrâneas. A mesma armazena o efluente pré-tratado nas águas subterrâneas e melhora a qualidade do mesmo durante o processo de percolação no solo. A infiltração controlada em solos tropicais pode contribuir para a qualidade das águas subterrâneas e balanço hídrico, servindo assim como fonte para o abastecimento de água.
Essa tese tem como objetivo a identificação de áreas e solos propícios à recarga artificial de águas subterrâneas no Distrito Federal a fim de dar suporte à gestão decentralizada de tratamento de efluentes. Para a identificação dessas áreas, amostras representativas à diferentes tipos de solos foram obtidas. As amostras foram examinadas de acordo com suas propriedades pedológicas e geoquímicas. Para a caracterização das condições hidráulicas não saturadas, realizaram-se diversos testes de infiltração in situ, bem como o monitoramento 3D. Ainda, determinou-se para cada solo o potencial de retenção de poluentes através de testes de coluna insaturados, hidroquímico e geoelétricos. Dessa forma foi possível calcular os potenciais de retenção para cada solo quando utilizados efluentes sintéticos.
Com base na contabilização de todos os dados hidroquímicos, calculou-se os potenciais de retenção de poluentes para o determinado efluente de composição conhecida. Mais a frente, para a implementação de dados hidráulicos e dados dos testes de coluna, utilizou-se uma análise de utilidade considerando todos os parâmetros. Finalmente, estudos de laboratório e campo foram combinados em uma análise baseada em sistema de informação geográfica (SIG). O mesmo permite o cruzamento de um determinado parâmetro obtido com uma base de dados georeferenciados (p. ex. classes de solos) a fim de identificar as áreas mais propícias. Parâmetros tais como declividade, uso e cobertura de solo foram incluídos nessa análise.
Após a avaliação dos balanços hidroquímicos, identificou-se que os solos jovens possuem um alto potencial de retenção de carbono orgânico total (COT). Os mesmos mostraram-se adequados para recarga de águas subterrâneas com efluente residuário pré-tratado. Como exemplo, o Gleisolo apresentou um potencial de retenção de aproximadamente 100% de COT. No entanto, é importante lembrar que, a fim de garantir uma retenção efetiva, a condutividade hidráulica do solo deve ser alta. Nesse caso, o Gleisolo apresentou baixos valores no teste de campo com uma condutividade hidráulica de 1,12 x 10-8 m/s.
Ainda, os dados hidráulicos e hidroquímicos medidos foram integrados à uma análise de uso-benefício. No caso, cada parâmetro recebe um peso de modo a atender às demandas de uma recarga efetiva de águas subterrâneas.
Resultados mostram que o grupo de solo classificado com Latossolo é propício para a recarga de águas subterrâneas. O mesmo oferece a melhor característica de infiltração e potencial de retenção de contaminantes para uma recarga artificial com efluentes pré-tratados. Declividade, uso e ocupação de solo, profundidade do solo e uma distância devida de áreas de conservação foram contemplados na análise de utilidade baseada em SIG. Além disso, os colos caracterizados pela análise de uso-benefício foram incluídos com o intuito de identificar as regiões mais propícias para a prática.
O resultado da tese é uma representação gráfica georeferenciada das áreas propícias para a aplicação de recarga artificial de águas subterrâneas. Ainda, a tese fornece evidências cruciais de parâmetros do solo que tem efeitos positivos na infiltração de efluentes pré-tratados. O monitoramento 3D de infiltração e a distribuição de resistividade medida mostram que infiltração controlada por gravidade influencia apenas a zona do solo imediata à superfície de irrigação. Mas a frente, foi determinado que o proxy da resistividade geoelétrica não é válido para o potencial de retenção de contaminantes condutores. / Der Distrito Federal ist durch eine starke Urbanisierung geprägt. Das ohnehin bereits starke Bevölkerungswachstum wird Prognosen zufolge weiter zunehmen. Der damit verbundene Anstieg des Wasserverbrauchs wird auch in absinkenden Grundwasserständen widergespiegelt. Weiterhin ist das westliche Zentralbrasilien aufgrund seiner Lage in den wechselfeuchten Tropen durch eine starke Saisonalität der Niederschläge geprägt. Das erhöhte Abwasseraufkommen in Verbindung mit extremen Niederschlagsereignissen kann zu einer deutlichen Überbelastung der vorhandenen Kläranlagen führen. In Extremsituationen kann ungeklärtes Abwasser in die Bodenzone gelangen und somit Schutzgüter wie Boden und Wasser kontaminieren. Eine effiziente Maßnahme gegenüber der unkontrollierten Versickerung von ungeklärtem Abwasser sowie zur Vorbeugung absinkender Grundwasserspiegel ist die gezielte Infiltration von vorbehandeltem Abwasser in Verbindung mit einer Grundwasseranreicherung. Diese Maßnahme umfasst einen zusätzlichen Reinigungsschritt des vorgereinigten Abwassers und dient zur Vorbeugung gegenüber absinkenden Grundwasserspiegeln.
Ziel der Arbeit war es, geeignete Böden und Flächen für eine Grundwasseranreicherung mit vorbehandeltem Abwasser im Distrito Federal auszuweisen. Zur Identifizierung geeigneter Böden wurden repräsentative Bodenproben auf ihre pedologischen und geochemischen Eigenschaften hin untersucht.
Zusätzlich wurden in situ Durchlässigkeitstests und ein Versickerungsmonitoring aufgebaut, um zur Klärung der Infiltrationseigenschaften beizutragen. Für die Laboruntersuchungen wurden die Bodenproben im Hinblick auf ihre Schadstoffrückhaltepotentiale untersucht. Dazu wurden kombinierte hydrochemische und geoelektrische sowie ungesättigte Säulenversuche durchgeführt. Dadurch war es möglich, Rückschlüsse auf die Sorptionsleistung der Böden gegenüber den Abwasserinhaltsstoffen einer künstlichen Abwasserlösung schließen zu können. Die Bodensäulen wurden mit einem künstlichen Abwasser mit bekannter Schadstoffzusammensetzung überstaut.
Auf der Grundlage der Bilanzierung aller hydrochemischen Daten wurden die Schadstoffrückhaltepotentiale für die Abwasserinhaltsstoffe berechnet. Anschließend wurden die experimentell ermittelten Parameter in einer Nutzwertanalyse zusammengefasst, um so geeignete Böden für eine effiziente Grundwasseranreicherung mit vorbehandeltem Abwasser zu identifizieren. Abschließend wurden die Feld- und Laboruntersuchungen mit einer GIS-basierten Nutzbarkeitsanalyse komplettiert, um die gemessenen Parameter mit weiteren vorliegenden, räumlich aufgelösten Daten verschneiden zu können. In diese Analyse wurden Parameter wie Gefälle, Landnutzung und Landbedeckung einbezogen.
Bei der Auswertung der hydrochemischen Bilanzen kristallisierten sich vorwiegend die jungen Böden aufgrund ihrer hohen Schadstoffrückhaltepotentiale als geeignete Böden für eine Grundwasseranreicherung mit vorbehandeltem Abwasser heraus. Exemplarisch wies der Gleissolo ein Sorptionspotential von fast 100 % für den Parameter TOC auf. Allerdings müssen Böden für eine effektive Grundwasseranreicherung mit vorbehandeltem Abwasser zusätzlich zu den hohen Sorptionsleistungen auch hohe hydraulische Durchlässigkeiten aufweisen. Für den Gleissolo wurde im Feldversuch die niedrigste hydraulische Durchlässigkeit von 1,12 x 10-8 m/s bestimmt. Durch die Einbindung der gemessenen hydraulischen und hydrochemischen Daten in eine Nutzwertanalyse konnten diese Parameter gewichtet werden, um so den Ansprüchen einer effektiven Grundwasseranreicherung gerecht zu werden.
Im Ergebnis der durchgeführten Untersuchungen hat sich gezeigt, dass sich die Bodengruppe der Latossole besonders gut für eine Grundwasseranreicherung mit vorbehandeltem Abwasser eignet. Diese Böden weisen die besten Infiltrationsbedingungen sowie gute Sorptionseigenschaften für eine effizient gestaltete Grundwasseranreicherung auf. Mit Hilfe der GIS-basierten Nutzbarkeitsanalyse geografischer Parameter wurden Flächen ausgezeichnet, die sich in Bezug auf Gefälle, Landnutzung/Landbedeckung, Bodentiefe und einer adäquaten Distanz zu Schutzgebieten für eine Grundwasseranreicherung mit vorbehandeltem Abwasser eignen.
Zusätzlich wurden die mit Hilfe der Nutzwertanalyse kategorisierten Böden in die Flächenidentifizierung einbezogen. Das Resultat dieser Arbeit liegt in Form einer Karte vor, in der die Gebiete, die für eine Grundwasseranreicherung mit vorbehandeltem Abwasser geeignet sind, nach Kategorien geordnet, verzeichnet sind. Zusätzlich dazu liefert die Arbeit entscheidende Hinweise auf Bodeneigenschaften, die sich positiv auf eine Abwasserinfiltration auswirken. Darüber hinaus konnte durch das geoelektrische 3D-Monitoring und der dabei gemessenen Verteilung des spezifischen elektrischen Widerstandes gezeigt werden, dass die Infiltration gravitativ gesteuert nur die Bodenzone direkt unterhalb der Verrieselung beeinflusste. Weiterhin wurde festgestellt, dass das Proxy des geoelektrischen Widerstandes im Labormaßstab nicht aussagekräftig genug ist, um Rückschlüsse auf die Sorption leitfähigkeitsrelevanter Abwasserinhaltsstoffe geben zu können.
|
Page generated in 0.0798 seconds