• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação da capacidade de campo em Latossolos com diferentes texturas / Determination of field capacity in Oxisols with different textures

Rezende, Carlos Henriques da Silva 22 July 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-05-25T11:15:58Z No. of bitstreams: 1 texto completo.pdf: 2204951 bytes, checksum: 3f4ce19b1d0adbca4886da2542cbf9aa (MD5) / Made available in DSpace on 2017-05-25T11:15:58Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2204951 bytes, checksum: 3f4ce19b1d0adbca4886da2542cbf9aa (MD5) Previous issue date: 2016-07-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A interação da molécula de água com a matriz do solo provoca o fenômeno da retenção de água. A quantidade de água retida no solo após o excesso ter sido drenado por ação da gravidade é denominada “capacidade de campo”, sendo estimada por meio de métodos de laboratório que podem não retratar o real valor de campo, gerando grandes desperdícios ou deficiências no manejo da irrigação, por exemplo. Diante do exposto, o objetivo deste trabalho foi determinar a capacidade de campo in situ pelo método da densidade de fluxo de água e comparar estes valores com estimativas obtidas por meio de métodos realizados em laboratório. O experimento foi realizado em um Latossolo Vermelho Amarelo Argiloso e um Latossolo Vermelho Amarelo Franco-argilo-arenoso, localizados nos municípios de Viçosa e João Pinheiro, respectivamente, com tempo de redistribuição de aproximadamente 2.160 h. Para o LVA de textura média a densidade de fluxo de 1,0 mm dia -1 foi encontrada em 10, 46, 70 e 94 h, com umidades e potenciais mátricos do solo de: 0,223 m 3 m -3 e 9,66 kPa; 0,232 m 3 m -3 e 11,12 kPa; 0,24 m 3 m -3 e 11,59 kPa; 0,243 m 3 m -3 e 11,83 kPa, para as profundidades 0,10; 0,20; 0,30 e 0,40 m, respectivamente. Para densidade de fluxo 0,1 mm dia -1 , os tempos correspondentes foram 190, 358, 354 e 674 h, com umidades e potenciais mátricos de: 0,199 m 3 m -3 e 17,41 kPa; 0,203 m 3 m -3 e 20,11 kPa; 0,214 m 3 m -3 e 20,42 kPa; 0,216 m 3 m -3 e 22,35 kPa para as profundidades 0,10; 0,20; 0,30 e 0,40 m, respectivamente. A melhor estimativa alcançada para a capacidade de campo deste LVA foi a densidade de fluxo 1,0 mm dia -1 , dado o longo tempo decorrido para se alcançar a densidade de 0,1 mm dia -1 . Para o LVA de textura argilosa, a densidade de fluxo de 1,0 mm dia -1 foi encontrada em 12, 24, 36 e 70 h, com umidades e potenciais mátrico de 0,45 m 3 m -3 e 1,86 kPa; 0,485 m 3 m -3 e 1,44 kPa; 0,513 m 3 m -3 e 1,43 kPa; 0,514 m 3 m -3 e 1,54 kPa para as profundidades 0,10; 0,20; 0,30 e 0,40 m, respectivamente. Valores bem maiores daqueles encontrados para o LVA de textura média, dado a menor capacidade de retenção de água naquele solo por apresentar menor teor de argila, matéria orgânica e microporosidade. Considerando a densidade de fluxo 0,1 mm dia -1 , os tempos encontrados foram 144, 192, 288 e 503 h, com umidades e potenciais mátrico de 0,43 m 3 m -3 e 4,14 kPa; 0,473 m 3 m -3 e 3,45 kPa; 0,504 m 3 m -3 e 3,41; 0,507 m 3 m -3 e 3,30 kPa para as profundidades 0,10; 0,20; 0,30 e 0,40 m, respectivamente. Para o LVA de textura argilosa a densidade de fluxo de 0,1 mm dia -1 é a melhor estimativa para os valores de capacidade de campo, com redução do fluxo inicial da ordem de 25, 38, 48 e 54 vezes para as profundidades 0,10; 0,20; 0,30 e 0,40 m, respectivamente. Os potenciais mátricos desta densidade de fluxo variaram entre 3,3 e 4,14 kPa. O método de laboratório que mais se aproximou da capacidade de campo no LVA de textura média foi a umidade equivalente ao potencial mátrico médio de 10 kPa, obtido por meio da CRA. Os demais métodos apresentaram baixa concordância com o método de campo, sub ou superestimando as estimativas alcançadas. Para o Latossolo de textura argilosa, todos os métodos apresentaram baixa similaridade com o método de campo, devendo-se considerar umidade da CRA entre valores de 3,3 e 4,14 kPa, encontrados em campo neste trabalho. O equivalente de umidade e ponto de inflexão das curvas de retenção de água, tanto obtida pela mesa de tensão + extrator de Richards, como pelo método da evaporação, demonstraram sempre dispersão dos dados em comparação com o método de campo, além de baixo coeficiente de determinação, demostrando não serem adequados para estimar a capacidade de campo para estes solos. / The interaction of water molecule with the soil matrix causes water retention phenomenon. The amount of water retained in the soil after draining the excess by gravity is called "field capacity", estimated by laboratory methods that may not portray the actual field value, generating large waste or deficiencies in management irrigation, for example. Thus, the aim of this work was to determine the in situ field capacity by the water flow density method and to compare these values with estimates obtained using laboratory methods. The experiment was conducted in a clayey Oxisol and franco Latosol sandy clay, located in the municipalities of Viçosa and João Pinheiro, respectively, With redistribution time of approximately 2,160 h. For the average LVA texture, a flow density of 1,0 mm day -1 was found at 10, 46, 58 and 70 h with soil moisture and matric potentials: 0,223 m 3 m -3 and 9,66 kPa; 0,232 m 3 m -3 and 11,12 kPa; 0,24 m 3 m -3 and 11,59 kPa; 0,243 m 3 m -3 and 11,83 kPa, at depths of 0,10; 0,20; 0,30 and 0,40 m, respectively. To flow density of 0,1 mm day -1 , the corresponding times were 190, 358, 574 and 694 h with potential humidities and matric potentials of: 0,199 m 3 m -3 and 17,41 kPa; 0,203 m 3 m -3 and 20,11 kPa; 0,214 m 3 m -3 and 20,42 kPa; 0,216 m 3 m -3 and 22,35 kPa to the depths 0,10; 0,20; 0,30 and 0,40 m, respectively. The best estimate reached for the field capacity of this LVA was the flow density of 1,0 mm day - , due to the long time to reach the density of 0,1 mm day -1 . To the clay-textured LVA, the flow density of 1,0 mm day -1 was obtained at 12, 24, 36 and 70 h with humidities and matric potentials of 0,45 m 3 m -3 and 1,86 kPa; 0,485 m 3 m -3 and 1,44 kPa; 0,513 m 3 m -3 and 1,43 kPa; 0,514 m 3 m -3 and 1,54 kPa to the depths 0,10; 0,20; 0,30 and 0,40 m, respectively. For the clay-textured LVA, the flow density of 0,1 mm day -1 is the best estimate for the field capacity values, with initial flow reduction of the order of 25, 38, 48 and 54 times at depths 0,10; 0,20; 0,30 and 0,40 m, respectively. The potentiometric potentials of this flux density ranged from 3,3 to 4,14 kPa. The laboratory method that most approached the field capacity in the medium texture LVA was the moisture equivalent to the average matric potential of 10 kPa, obtained through CRA. The other methods presented low agreement with the field method, underestimating or overestimating the obtained estimates. For the clay-textured Oxisol, all methods presented low similarity with the field method, considering the moisture content of CRA between 3,3 and 4,14 kPa, found in this field. The moisture equivalent and inflection point of water retention curves, both prepared by the tension table + Richard ́s extractor, such as by the method of evaporation, always displayed data dispersion compared to the field method, in addition to low coefficient of determination, showing no they are suitable for estimating field capacity for these soils.
2

Avaliação das técnicas de laboratório e campo para realização de ensaios de permeabilidade de solos / Evaluation of laboratory and field techniques to perform soil permeability tests

Fernandes, Marcos Túlio 10 March 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-06-13T13:08:03Z No. of bitstreams: 1 texto completo.pdf: 5266479 bytes, checksum: 9df900f8f2b36cd9928c836253b4a1c5 (MD5) / Made available in DSpace on 2017-06-13T13:08:03Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5266479 bytes, checksum: 9df900f8f2b36cd9928c836253b4a1c5 (MD5) Previous issue date: 2017-03-10 / Determinar o valor do coeficiente de permeabilidade (K) é uma das grandes premissas de diversos projetos e análises envolvendo o fluxo de água no solo, portando esse parâmetro deve ser bem caracterizado, pois este fluxo influencia no processo de infiltração em diversas obras da engenharia geotécnica. O objetivo deste trabalho foi avaliar qual técnica de ensaio reporta melhor esta propriedade do solo, as premissas de execução de cada uma, comparar os resultados dos ensaios executados em campo com os de laboratório e discutir a discrepância entre eles. Para desenvolver este estudo foram realizados ensaios em três áreas com solos distintos, todas situadas no município de Viçosa-MG; a primeira área estudada está localizada próxima à estação de tratamento de água na rua Saae, sendo esta constituída por um solo classificado como argiloso; a segunda se situa próximo ao Aeroporto, ao lado da BR 356, saída do município de Viçosa em direção a Ubá, sendo o solo presente no local considerado um silte argiloso; e a terceira área está situada dentro da Universidade Federal de Viçosa em um local conhecido como Vila Secundino e é constituída por uma areia siltosa. Nestas áreas foram executados ensaios de campo com o permeâmetro de carga constante Guelph, permeâmetro de tubo sob carga variável e infiltrômetro de anéis concêntricos, sendo todos os ensaios feitos na camada superficial do solo a 15 cm de profundidade, e também, ensaios em laboratório com o permeâmetro de parede rígida e permeâmetro de parede flexível utilizando-se a célula triaxial, em amostras indeformadas e compactadas. Foram ainda verificadas algumas correlações para coeficiente de permeabilidade em solo granular para a área do Vila Secundino. Nos ensaios com o infiltrômetro, o modelo que melhor representou a curva de velocidade de infiltração foi o de Kostiakov e Lewis, embora os demais modelos demonstrassem boa resposta; a velocidade de infiltração básica (VIB) encontrada no ensaio tendeu a ser maior do que a obtida pela equação de Kostiakov (1932) e houve uma boa aproximação do modelo de Massad (1986) com a VIB do ensaio. Com os ensaios no permeâmetro de tubo, foi possível verificar que o fator forma empregado no cálculo varia com o tipo de solo, mostrando-se menor ou maior dependendo do solo. Com o permeâmetro Guelph notou-se que a utilização do método de uma carga reporta valores similares ao de duas cargas para (K), e que a escolha do fator (α*) influencia diretamente no cálculo. Ao analisar as equações para o cálculo de (K) em solo granular verificou-se que a elaborada por Amer e Award (1974) demonstrou melhor desempenho dentre as equações analisadas. Nos ensaios de laboratório não houve uma diferença significativa dos valores de (K) encontrados com o permeâmetro de parede rígida e parede flexível, o que pode ser notado é uma tendência a redução do coeficiente de permeabilidade no solo do ETA nos ensaios executados no permeâmetro de parede flexível. Dos ensaios de campo realizados observou-se que todos reportaram valores maiores do que os de laboratório, sendo o permeâmetro Guelph o que demonstrou melhor desempenho em todas as áreas estudadas, quando comparado com os ensaios de laboratório. Notou-se ao final das análises que tratamentos estatísticos envolvendo ensaios de permeabilidade são muito difíceis devido ao alto coeficiente de variação encontrado nos ensaios, resultando apenas em uma noção de ordem de grandeza entre os valores obtidos, e que a escolha de qual ensaio utilizar, dependerá da finalidade a que o mesmo se destina. / Determining the value of the permeability coefficient (K) is one of the main assumptions of several projects and analyzes involving the flow of water in the soil, it should be well characterized, as this flow influences the infiltration process, drainage projects, check of barriers for contaminants, among other works of geotechnical engineering. The objective of this work was to evaluate which test technique reports this property of the soil better and the premises of execution of each one, comparing the results of the tests performed in the field with those of the laboratory, exemplifying the discrepancy between them. In order to develop this study, tests were carried out in three regions with distinct soils, all located in the municipality of Viçosa-MG; The first region studied is located near the water treatment plant in Saae street, which is made up of a soil classified as clayey, the second is located near the Airport, next to the BR 356, leaving the municipality of Viçosa in the direction of Ubá. The soil present in the site being considered clay silt, and the third area is present within the Federal University of Viçosa in a place known as Vila Secundino, consisting of silty sand. In these areas, field tests were carried out with the Guelph constant load permeameter, tube permeate under variable load and concentric ring infiltrator, all the tests described being done in the soil surface layer at 15 cm depth, as well as laboratory tests with the rigid wall permeameter and flexible wall permeability using the triaxial cell, in undisturbed and compacted samples, besides verifying some relations for the permeability coefficient in granular soil. In the tests with the infiltrator, the model that best represented the infiltration speed curve was that of Kostiakov and Lewis, although the other models showed good response; The VIB found in the assay tended to be greater than that of the Kostiakov equation (1932) and there was a good approximation of the Massad (1986) method with the VIB of the assay. With the test tube permeameter, we can see that the form factor used in the calculation, varies with the type of soil, showing lesser or greater depending upon the soil. With the Guelph permeameter it was observed that the use of the one- charge method reports values similar to those of two loads for (K), and that the choice of factor (α *) directly influences the calculation. When analyzing the equations for the calculation of (K) in granular soil it was verified that the one elaborated by Amer and Award (1974) demonstrated better performance among the equations analyzed. In the laboratory tests there was not a significant difference of the values of (K) found with the rigid wall permeability and flexible wall, what can be noticed is a tendency to reduce the permeability coefficient in the soil of the ETA in the tests executed in the permeameter of Flexible wall. From the field tests performed, it was observed that all reported higher values than those from the laboratory, the Guelph permeameter being the closest to the laboratory tests. It was notable at the end of the analyzes that statistical treatments involving permeability tests are very difficult due to the high coefficient of variation found in the tests, and can only have a notion of order of magnitude between the values obtained, and that the choice of which assay to use, will depend on the purpose for which it is intended.
3

Impacto das ações antrópicas e do clima no uso e ocupação do solo na Bacia Hidrográfica do Rio Pajeú

FRANÇA, Luciana Mayla de Aquino 22 February 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-20T21:09:17Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luciana Mayla de Aquino França.pdf: 6387653 bytes, checksum: 97f7f7917d8ad768f84a66be005d1909 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-21T18:57:45Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luciana Mayla de Aquino França.pdf: 6387653 bytes, checksum: 97f7f7917d8ad768f84a66be005d1909 (MD5) / Made available in DSpace on 2018-09-21T18:57:45Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luciana Mayla de Aquino França.pdf: 6387653 bytes, checksum: 97f7f7917d8ad768f84a66be005d1909 (MD5) Previous issue date: 2017-02-22 / CAPES / Desde o início da ocupação humana sob a terra as bacias hidrográficas são as regiões que mais favorecem o desenvolvimento humano, principalmente em áreas semiáridas, onde ficar próximo ao rio era questão de sobrevivência. Com isso e a intensificação de fatores climáticos, o uso e ocupação do solo dessas áreas tem sofrido grandes mudanças. Neste sentido, o objetivo desde estudo é analisar como os impactos das ações antrópicas e do clima vem afetando a dinâmica do uso e ocupação do solo na bacia hidrográfica do rio Pajeú. Para isso, foram utilizadas imagens do sensor MODIS, a bordo do satélite TERRA, referente ao produto MCD12Q1 para o período compreendido entre os anos de 2001 e 2013 para a realização de treze mapas de uso e ocupação do solo de forma a realizar uma análise espaço-temporal do uso e ocupação do solo na área de estudo. Para o estudo climático, foram utilizados dados anuais de 8 estações meteorológicas no período de 1998 a 2013, para estimar o índice de anomalia de precipitação. Os resultados apontam que ao longo dos anos ocorreram mudanças principalmente referentes a diminuição de cobertura vegetal densa e aumento de áreas sem vegetação, bem como diminuição de terras férteis e aumento de áreas de vegetação seca. O Índice de Anomalia de Chuva-IAC mostra que a precipitação é fator fundamental para a análise da variação espacial e temporal do uso e ocupação do solo em áreas semiáridas. Com relação a correlação, não foram encontrados valores significantes estatisticamente para a comparação entre uso e ocupação do solo e índice de anomalia de chuva, porém para a classe vegetação arbustiva aberta foi encontrado valor de r de -4.888. / Since the beginning of human occupation under ground river basins are the regions that most favours human development, especially in semi-arid areas, where to stay near the River was a matter of survival. With that and the intensification of climatic factors, use and soil occupation of these areas has undergone major changes. In this sense, the objective since study is to analyze how the impacts anthropogenic and climate actions comes affecting the dynamics of the use and occupation of the ground in the catchment area of the river Pajeú. For this, we used images from the MODIS sensor aboard the TERRA satellite, for the MCD12Q1 product to the period between the years of 2001 and 2013 for the implementation 13 maps of soil use and occupation in order to achieve a spatio-temporal analysis of the use and occupation of the soil in the study area. For climate study, monthly data were used 8 seasons weather in 1998 to 2013 period, to estimate the index of precipitation anomaly. The results show that over the years occurred changes mainly related to the decrease of dense vegetation cover and increased areas without vegetation, as well as decrease of fertile lands and increase areas of dry vegetation. The Rain Anomaly index-IAC shows that precipitation is factor central to the analysis of spatial and temporal variability of use and occupation of the soil in semi-arid areas. In relation to the correlation, no significant values were found statistically for the comparison between usage and occupation of the soil and the index of rainfall anomaly, but for the open Bush vegetation class was found value of R-4,888.
4

Teor foliar de nitrogênio em videira fertirrigada e sua relação com atributos do solo e da planta /

Silva, Thassio Monteiro Menezes da January 2020 (has links)
Orientador: Luís Henrique Bassoi / Resumo: Sensores podem auxiliar no monitoramento do nitrogênio no tecido foliar e da água no solo, mas para esse propósito eles necessitam ser calibrados. Assim, o presente trabalho teve como objetivo propor um procedimento para o uso do clorofilômetro em ma área de produção comercial de uva para vinho, no contexto da vitivinicultura de precisão, avaliando a variabilidade temporal do teor de nitrogênio foliar e as suas relações com as zonas homogêneas de solo e da planta. O estudo foi desenvolvido no município de Espirito Santo do Pinhal, estado de São Paulo, no ciclo de produção de 2019 de um vinhedo com a cv. Chardonnay sobre o porta-enxerto Paulsen 1103. O vinhedo foi irrigado e fertirrigado por um sistema de irrigação por gotejamento. O equipamento HS2 HydroSense, calibrado para diferentes zonas homogêneas quanto a fração granulométrica do solo, foi utilizado em 6 datas durante o ciclo de produção para a determinação do conteúdo de água a 0-20 cm de profundidade, e em 20 pontos por zona. O índice relativo de clorofila foi medido pelo clorofilômetro ClorofiLOG CFL 1030 em 4 datas durante o ciclo de produção, e em 40 plantas por data. Para a calibração do clorofilômetro, amostras de folhas foram coletadas para a determinação em laboratório dos teores de clorofila e de nitrogênio. A produção por planta, número de cachos por planta, massa média de cachos por planta e produtividade da área total foram determinados. A maturação tecnológica das bagas foi observada por amostragens periód... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Sensors can assist in monitoring leaf tissue nitrogen and soil water, but for this purpose they need to be calibrated. Thus, the present study aimed to propose a procedure for the use of a chlorophyll meter in a commercial growing area of wine grapes, within the context of precision viticulture, evaluating the temporal variability of leaf nitrogen content and its relationship with homogeneous soil and plant zones. The study was carried out at Espirito Santo do Pinhal, state of São Paulo, Brazil, in the 2019 growing season of vineyard of cv. Chardonnay grifted on Paulsen 1103 rootstock. Plants were irrigated and fertigated by a drip irrigation system. The HS2 HydroSense equipment, calibrated for different homogeneous zone of soil fractions, was used to determine the water content at 0-20 cm depth in 6 days throughout the growing season, at 20 points in each zone. The relative chlorophyll index was measured using the chlorophyll meter ClorofiLOG CFL 1030 in 4 days throughout the growing season, in 40 plants by day. Leaf samples were collected for laboratory determination of chlorophyll and nitrogen contentes and calibration of the chlorophyll meter. The production per plant, number of bunches per plant, average mass of bunches per plant and yield (total area) were determined. The technological maturation was observed by periodic sampling of berries to determination of pH, malic acid and soluble solids in laboratory. From the mathematical models generated, the chlorophyll meter ... (Complete abstract click electronic access below) / Mestre
5

Sistema para avaliação da umidade relativa do solo utilizando a análise de impedância e técnicas de ultrassom

Damacedo, João Marcos Ferreira 21 May 2010 (has links)
Visando a melhoria dos processos agrícolas para produção sustentável de alimentos, o conhecimento do teor de umidade relativa vem a cooperar no processo de irrigação, apontada como uma grande consumidora de água, além de auxiliar em estudos hidrológicos, meteorológicos, geotécnicos, dentre outros. Este trabalho apresenta o desenvolvimento do hardware e firmware de um protótipo para ser utilizado com técnicas de ultrassom e análise de impedância, visando o desenvolvimento de futuros produtos para avaliar o teor de água no solo. Para a análise da impedância foi utilizado um sensor de placas paralelas, separadas 24 mm uma da outra, utilizadas juntamente com o hardware e firmware desenvolvido, para detectar a variação da constante dielétrica do solo com acréscimo de água, através da variação da fase dos sinais de tensão e corrente ao passar pelo sensor inserido no meio. Obteve-se, ao analisar 15 amostras, uma relação logarítmica crescente da variação de fase em função do acréscimo de água no solo. No estudo da caracterização da umidade do solo através do ultrassom, obteve-se resultados preliminares expressivos para as mudanças da amplitude dos sinais ultrassônicos de 40 kHz e 100 kHz no modo transmissão/recepção ao propagar-se no solo com diferentes níveis de umidade. / To improve agricultural processes for sustainable food production, knowledge of the moisture is useful to cooperate in the irrigation process, identified as a major consumer of water, besides helping in hydrological studies, meteorological, geotechnical, among others. This paper presents the development of the hardware and firmware of a prototype to be used with ultrasound techniques and impedance analysis for the development of future products to evaluate the water content in soil. For the impedance analysis, it was used a parallel plate sensor, with the plates separated from 24 mm each other, used together with the hardware and firmware developed to detect the variation of dielectric constant with the increase of soil water, by varying the phase of voltage and current signals in the sensor inserted in the medium. The results obtained, when analyzing 15 samples, presented a ratio of logarithmic growing of the phase variation due to increased soil water. In the study of characterization of soil moisture using a transmission/reception ultrasound system, the preliminary results have shown significant changes in the amplitude of ultrasonic waves of 40 kHz and 100 kHz propagating through the soil at different moisture levels.
6

Sistema para avaliação da umidade relativa do solo utilizando a análise de impedância e técnicas de ultrassom

Damacedo, João Marcos Ferreira 21 May 2010 (has links)
Visando a melhoria dos processos agrícolas para produção sustentável de alimentos, o conhecimento do teor de umidade relativa vem a cooperar no processo de irrigação, apontada como uma grande consumidora de água, além de auxiliar em estudos hidrológicos, meteorológicos, geotécnicos, dentre outros. Este trabalho apresenta o desenvolvimento do hardware e firmware de um protótipo para ser utilizado com técnicas de ultrassom e análise de impedância, visando o desenvolvimento de futuros produtos para avaliar o teor de água no solo. Para a análise da impedância foi utilizado um sensor de placas paralelas, separadas 24 mm uma da outra, utilizadas juntamente com o hardware e firmware desenvolvido, para detectar a variação da constante dielétrica do solo com acréscimo de água, através da variação da fase dos sinais de tensão e corrente ao passar pelo sensor inserido no meio. Obteve-se, ao analisar 15 amostras, uma relação logarítmica crescente da variação de fase em função do acréscimo de água no solo. No estudo da caracterização da umidade do solo através do ultrassom, obteve-se resultados preliminares expressivos para as mudanças da amplitude dos sinais ultrassônicos de 40 kHz e 100 kHz no modo transmissão/recepção ao propagar-se no solo com diferentes níveis de umidade. / To improve agricultural processes for sustainable food production, knowledge of the moisture is useful to cooperate in the irrigation process, identified as a major consumer of water, besides helping in hydrological studies, meteorological, geotechnical, among others. This paper presents the development of the hardware and firmware of a prototype to be used with ultrasound techniques and impedance analysis for the development of future products to evaluate the water content in soil. For the impedance analysis, it was used a parallel plate sensor, with the plates separated from 24 mm each other, used together with the hardware and firmware developed to detect the variation of dielectric constant with the increase of soil water, by varying the phase of voltage and current signals in the sensor inserted in the medium. The results obtained, when analyzing 15 samples, presented a ratio of logarithmic growing of the phase variation due to increased soil water. In the study of characterization of soil moisture using a transmission/reception ultrasound system, the preliminary results have shown significant changes in the amplitude of ultrasonic waves of 40 kHz and 100 kHz propagating through the soil at different moisture levels.

Page generated in 0.0882 seconds