• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Reduced Switch Count Multilevel Inverter Topologies for Open End Induction Motor Drives

Kshirsagar, Abhijit January 2016 (has links) (PDF)
MU LT I L E V E L inverters are becoming the preferred choice for medium voltage high power applications. Multilevel inverters have a number of inherent advantages over conventional two level inverters. The output voltage has multiple steps or levels, resulting in reduced dV/dt, which leads to lower electromagnetic interference, making it easier to meet electromagnetic compatibility (EMC) regulations. Multilevel inverters have a much lower effective switching frequency, which leads to a reduction in switching losses. The output voltage of multilevel inverters has a much lower harmonic content. In applications such as power conversion or grid-connection, filters need to be much smaller, or can be eliminated. In motor drive applications, the low harmonic content results in smoother, ripple-free shaft torque. The neutral-point clamped (NPC), cascaded H-bridge (CHB) and flying capacitor (FC) topologies were among the earliest multilevel topologies. NPC topologies require additional clamping diodes to clamp the output to the DC bus midpoint. CHB topologies use a number of isolated DC suplies to generate multilevel output. FC topologies work with a single DC link but use additional floating capacitors. Since then, a number derivatives and improvements to these topologies have been proposed. Topologies with low switch counts are desirable because of the corresponding reduction in system size and cost. A low total component count is also desirable since it results in better reliability. Induction motors in high power applications are often operated in the open-end configuration. Here, the start terminals of the motor phase windings are connected to one three phase inverter, while the end terminals are connected to a second three-phase inverter. The two inverters are typically powered by isolated supplies to prevent the flow of common mode currents through the motor. The open end configuration has a number of advantages It can be used with nearly all high power motors with no need for electrical or mechanical modification, since all six winding terminal are available externally. The two inverters driving the open-end motor are effectively cascaded. As a result, two inverters of lower voltage and power rating can replace a single inverter with higher voltage and power rating. In addition, if one of the inverter fails, it can be bypassed and the system can be operated at reduced power. In many applications such as heating, ventilation and air conditioning (HVAC), the load power is proportional to the cube of the shaft speed, so a 50% reduction in power translates to only 20% reduction in speed, thereby improving overall system reliability. The cascading of inverters also enables multilevel operation, which is exploited for the topologies proposed in this thesis. In the open-end configuration it is important to ensure that both the DC supplies deliver power to the load. Otherwise, power can circulate through the motor windings. In addition, if the two inverters are powered by rectifier supplies, the DC bus of one inverter can charge uncontrollably, resulting in distortion of phase voltages and currents. If DC bus overcharging continues unchecked the DC bus voltage can even exceed the system rating, resulting in permanent damage. This thesis proposes two novel topologies for open-end induction motor drives with low switch counts. Both topologies are powered by two unequal, isolated DC sources having DC voltages in a 3:1 ratio. Multiple levels in the output voltage are obtained using a number of floating capacitors in each phase. Modulation and control schemes are also proposed for both topologies to ensure that DC bus overcharging never occurs, while all the capacitor voltages are kept balanced at their nominal values. The first of these two topologies is a nine level inverter for open end induction motor drives. It consists of two three-level flying capacitor inverters connected to the induction motor in the open end configuration. The two inverters are powered by DC sources of voltage 6VDC/8 and 2VDC/8, which generates an effective phase voltage having nine levels in steps of VDC/8. This topology has only eight switches and two floating capacitors per phase. The space vector structure for this topology is hexagonal, and has 217 space vector locations. A space-vector based formulation is used to determine the pole voltage of the inverter such that DC bus over charging is prevented. In addition, selection of switching states is used to balance the voltages of all floating capacitors. This scheme allows the floating capacitors to be charged up during system startup, thereby eliminating the need for separate pre-charging circuitry. A level-shifted carrier PWM based modulation scheme has been developed, which can be used with both scalar and vector control schemes. The gating signal for switches turning on must be delayed by a small amount (to allow the complementary switch to turn of), failing which current shoot through can occur. This delay is called dead time, during which gate signals to both complementary devices are turned of. Under certain conditions in the flying capacitor topology, the pole voltage can contain large undesirable transients during the dead time which result in phase current distortion, and electromagnetic noise. A novel scheme to eliminate this problem is proposed using a digital state machine approach. The switching state for each subsequent switching interval is determined based on the present switching state such that the pole voltage does not contain a transient, without affecting the phase voltage of the inverter, and irrespective of the current magnitude or direction. The state machine was implemented using an FPGA, and required an additional computation time of just 20ns, which is much smaller than the inverter dead time duration of typically 2.5µs. The second novel topology proposed in this thesis is a seventeen level inverter for an open end induction motor drive. Here, one three-level inverter and one seven-level inverter are connected to the two ends of the induction machine. The three-level inverter is a flying capacitor inverter. The seven-level inverter is a hybrid topology – it consists of an H-bridge cascaded to each phase of a three level flying capacitor inverter. This scheme is also powered by two isolated DC sources in 3:1 ratio with magnitudes 12VDC/16 and 4VDC/16. The effective phase voltage has seventeen levels in steps of VDC/16. This topology has a total of twelve switches and three floating capacitors per phase. The space vector structure for this topology is hexagonal, and has 817 space-vector locations. Space vector analysis was used to determine the pole voltages, and the switching states such that DC bus overcharging is prevented while also balancing the voltages of the floating capacitors. A non-iterative algorithm was developed for determining the switching states, suitable for implementation in digital logic using an FPGA. The scheme is able to charge the all capacitors at startup as well, eliminating the need for separate pre-charging circuits. Hardware prototypes were built for both the topologies described above for experimental verification, and used to drive a three phase 50Hz, 1.5kW, four pole induction motor in V/f control mode. The inverters topologies were built using 1200V, 75A IGBT half-bridge modules (Semikron SKM75GB12T4) with hybrid opto-isolated gate drivers (Mitsubishi M57962). Three phase rectifiers were used to create the asymmetric DC supplies Hall effect sensors were used to sense the DC link and floating capacitor voltages and phase currents (LEM LV20P voltage sensors and LA55 current sensors). Signal conditioning circuitry was built using discrete components. The PWM signals and V/f controller were implemented using a digital signal processor (Texas Instruments TMS320F28335). Synchronous PWM with was used to eliminate sub-harmonics from the phase voltage, and to ensure three-phase and half-wave symmetry. The internal ADC of the DSP was used for sampling all voltages and currents. The remaining digital logic for switch state selection was implemented on a FPGA (Xilinx Spartan3 XC3S200). Dead time functionality was also implemented within the FPGA, eliminating the need for separate dead time hardware. Both topologies were first tested for steady state operation over the full modulation range, and the pole voltages, phase voltages and phase currents were recorded. System startup, and the ability of the controllers to balance all the capacitors at startup was tested next. The capacitor voltages were also observed during sudden loading, by quickly accelerating the motor. Finally, the phenomenon of DC bus overcharging was also demonstrated. These results demonstrate the suitability of the proposed topology for a number of applications, including industrial drives, alternate energy systems, power conversion and electric traction.
2

Multilevel Dodecagonal Space Vector Structures and Modulation Schemes with Hybrid Topologies for Variable Speed AC Drives

Kaarthik, R Sudharshan January 2015 (has links) (PDF)
MULTILEVEL inverters are the preferred choice of converters for electronic power conversion for high power applications. They are gaining popularity in variety of industrial applications including electric motor drives, transportation, energy management, transmission and distribution of power. A large portion of energy conversion systems comprises of multilevel inverter fed induction motor drives. The multilevel inverters are ideal for such applications, since the switching frequency of the devices can be kept low. In conventional two level inverters, to get nearly sinusoidal phase current waveform, the switching frequency of the inverter is increased and the harmonics in the currents are pushed higher in the frequency spectrum to reduce the size and cost of the filters. But higher switching frequency has its own drawbacks – in particular for medium voltage, high power applications. They cause large dv_/ dt stresses on the motor terminals and the switching devices, leading to increased electromagnetic interference (EMI) problems and higher switching losses. Harmonics in the motor currents can further be minimized by adopting dodecagonal voltage space vector (SV) switching (12-sided polygon). In case of dodecagonal SV switching, the fifth and seventh order (6n , 1, n = odd) harmonics are completely eliminated for the full modulation range including over modulation and twelve step operation in the motor phase voltages and currents. In addition to low order harmonic current suppression, the linear modulation range for dodecagonal SV switching is also more by 6% when compared to that of the conventional hexagonal SV switching. The dodecagonal voltage SV structure is made possible by connecting two inverters with DC-link voltages Vd and 0:366Vd on either side of an open-end winding induction motor. The dodecagonal space vector switching can be used to produce better quality phase voltage and current waveforms and overcome the problem of low order fifth and seventh harmonic currents and to improve the range for linear modulation while reducing the switching frequency of the inverters when compared to that of the conventional hexagonal space vector based inverters. This thesis focuses on three aspects of multilevel dodecagonal space vector structures (i) Two new power circuit topologies that generate a multilevel dodecagonal voltage space vector structure with symmetric triangles, (ii) A multilevel dodecagonal SV structure with nineteen concentric dodecagons, (iii) Pulse width modulation (PWM) timing calculation methods for a general N-level dodecagonal SV structure. (i) Two new power circuit topologies capable of generating multilevel dodecagonal voltage space vector structure with symmetric triangles with minimum number of DC link power supplies and floating capacitor H-bridges are proposed. The first power topology is composed of two hybrid cascaded five level inverters connected to either side of an open end winding induction machine. Each inverter consists of a three level neutral point clamped (NPC) inverter, cascaded with an isolated capacitor fed H-bridge making it a five level inverter. The second topology is a hybrid topology for a normal induction motor (star or delta connected), where the power is fed to the motor only from one side. The proposed scheme retains all the advantages of multilevel topologies as well the advantages of the dodecagonal voltage space vector structure. Both topologies have inherent capacitor balancing for floating H-bridges for all modulation indices including transient operations. The proposed topologies do not require any pre-charging circuitry for startup. PWM timing calculation method for space vector modulation is also explored in this chapter. Due to the symmetric arrangement of congruent triangles within the voltage space vector structure, the timing computation requires only the sampled reference values and does not require any iterative searching, off-line computation, look-up tables or angle estimation. Experimental results for steady state operation and transient operation are also presented to validate the proposed concept. (ii) A multilevel dodecagonal voltage space vector structure with nineteen concentric do-decagons is proposed for the first time. This space vector structure is achieved by connecting two sets of asymmetric hybrid five level inverters on either side of an open-end winding induction motor. The dodecagonal structure is made possible by proper selection of DC-link voltages and switching states of the inverters. In addition to that, a generic and simple method for calculation of PWM timings using only sampled reference values (v and v ) is proposed. This enables the scheme to be used for any closed loop application like vector control. Also, a new switching technique is proposed which ensures minimum switching while eliminating the fifth and seventh order harmonics and suppressing the eleventh and thirteenth harmonics, eliminating the need for bulky filters. The motor phase voltage is a 24-stepped waveform for the entire modulation range thereby reducing the number of switchings of the individual inverter modules. Experimental results for steady state operation, transient operation including start-up have been presented and the results of Fast Fourier Transform (FFT) analysis is also presented for validating the proposed concept. (iii) A method to obtain PWM timings for a general N-level dodecagonal voltage space vector structure using only sampled reference values is proposed. Typical methods that are used to find PWM timings for dodecagonal SV structures use modulation index and the reference vector angle, to get the timings T1 and T2 using trigonometric calculations. This method requires look-up tables and is difficult to implement in closed loop systems. The proposed method requires only two additions to compute these timings. For multilevel case, typical iterative methods need timing calculations (matrix multiplications) to be performed for each triangle. The proposed method is generic and can be extended to any number of levels with symmetric structures and does not require any iterative searching for locating the triangle in which the tip of the reference vector lies. The algorithm outputs the triangle number and the PWM timing values of T0, T1 and T2 which can be set as the compare values for any carrier based PWM module to obtain space vector PWM like switching sequences. Simulation and experimental results for steady state and transient conditions have been presented to validate the proposed method. A 3.7 kW, 415 V, 50 Hz, 4-pole open-end winding induction motor was used for the experimental studies. The semiconductor switches that were used to realize the power circuit for the experiment were 75 A, 1200 V insulated-gate bipolar transistor (IGBT) half-bridge modules (SKM75GB12T4). Opto-isolated gate drivers with desaturation protection (M57962L) were used to drive the IGBTs. For the speed control and PWM timing computation a digital signal processor (DSP-TMS320F28335) with a clock frequency of 150 MHz was used. For modulation frequencies 10 Hz and below, a constant sampling frequency of 1 kHz was used as the frequency modulation ratio is high. For modulation frequencies above 10 Hz, synchronous PWM strategy was used. The time duration Ts is the sampling interval for which the timings T1 , T2 and T0 are calculated. As in the case of any synchronous PWM method, the duration of sampling time (Ts) is a function of the fundamental frequency of the modulating signal. In this case, Ts = 1_.fm • 12n) sec. where fm is fundamental frequency in Hertz and ‘n’ is the number of samples per 30ý dodecagonal sector. The PWM timings and the triangle data (from the DSP) is fed to field programmable gate array (FPGA) (SPARTAN XC3S200) clocked at 50 MHz where the actual gating pulses are generated. The capacitor balancing algorithm and the dead-time modules were implemented within FPGA. No external hardware was used for generation of dead-time. The dead-time block generates a constant dead-time of 2 s for all the switches. Extensive testing was done for steady state operations and transient operations including quick acceleration and start-up to validate the proposed concepts. With the advantages like extension of linear modulation range, elimination of fifth and seventh harmonics in phase voltages and currents for the full modulation range, suppression of eleventh and thirteenth harmonics in phase voltages and currents, reduced device voltage ratings, lesser dv_dt stresses on devices and motor phase windings, lower switching frequency, inherent cascaded H-bridge (CHB) capacitor balancing, the proposed space vector structures, the inverter power circuit topologies, the switching techniques and the PWM timing calculation methods can be considered as viable schemes for medium voltage, high power motor drive applications.

Page generated in 0.0442 seconds