• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Static and Dynamic Characterization of Ionic Polymer Metal Composites - 'Artificial Muscles'

Mudigonda, Ashwin 18 April 2006 (has links)
No description available.
2

Static and Dynamic Characterization of power semiconductors

Mejean, Alexandre January 2019 (has links)
Characterizing  power  switches  is  an  indispensable  step  when  designing  a  converter.  This  thesisinvestigates ways to achieve static and dynamic characterization of semiconductors for high power applications such as power grid or train traction. The static characterization has been tested with a Keysight B1506A device analyzer. The problems encountered have been analyzed and corrected.Then the design of a high current switching test bench for dynamic characterization is explained. The full-bridge  configuration  allows  controlled  and  spontaneous  commutations  so  the  bench  can measure hard and soft switching. The voltage can be up to 10 kV and the current up to 3 kA during the commutation. The choice of the probes is justified. The issues of bandwidth, input impedance and common mode current are taken into account. Data are processed in order to interpolate theswitching loss in hard and soft switching. / Karaktärisering  av  halvledarbrytare  är  ett  viktigt  steg  när  man  utformar  en  omvandlare.  Dennaavhandling undersöker olika sätt att uppnå statisk och dynamisk karakterisering av halvledare för högeffekttillämpningar såsom elnät eller ellok. Statisk karaktäriseringen har utförts med en Keysight B1506A-enhetsanalysator. De problem som uppstått har analyserats och korrigerats.Utformningen    av    en    testbänk    för    dynamisk    karakterisering    förklaras.    Den    kompletta bryggkonfigurationen möjliggör kontrollerad och spontan kommutation med spänningar upp till 10 kV och  strömmar  upp till 3 kA så att  bänken kan mäta hård  och mjuk  växling.  Valet  av sonderna förklaras.   Frågorna   om   bandbredd,   ingångsimpedans   och   common-mode   ström   tas   med   iberäkningen. Data bearbetas för att interpolera kopplings förlusten i hård och mjuk växling.

Page generated in 0.1384 seconds