Systémy vytápění a chlazení v kancelářských provozech / Heating and cooling systems in office operationsDostál, Petr January 2020 (has links)
The diploma thesis deals with the design of the heating and cooling system, inclu-ding hot water preparation for the administrative part of the production hall. The first part of the thesis briefly discusses the history of heating and cooling of office buildings, legislative requirements and current solutions. The second part contains the design of the entire heating and cooling system with heat pump as a source of heat and cold. The final part of the thesis describes the experimental measure-ment and evaluation of the efficiency of the ice rink source.
|
42 |
Kotelny na biomasu / Biomass boiler roomEgerle, Dušan January 2013 (has links)
The aim of this project is heating and warm water preparation for apartment block in Choceň (Pardubice region). Apartment block has three aboveground heated floors and one underground unheated floor. The heat source is gasifying firewood boiler or pellet boiler which is at the same time used for water heating but only in the winter time. The other parts of the year the solar collectors are installed and used for water heating. The heat source is located in detached room with its own access, in boiler room.
|
43 |
Analýza možností akumulační tepelné elektrárny v podmínkách ČR / Use storage thermal power in Czech republicBednář, František January 2014 (has links)
This diploma’s thesis analyzes the possibility of accumulation of thermal power plants in the Czech Republic. The thesis is divided into several parts. The first part describes the different types of storage power plants, the historical development of power storage for compressed air and the appropriateness of their location. The second part is devoted to the design of storage power plant for compressed air in South Moravia. In the next chapter, a calculation is made of all equipment storage power plant, including turbo-compressor, combustion chamber, combustion turbines, the volume of storage tanks and two heat exchangers. The last part is the economic analysis of the return on investment of such a project.
|
44 |
Návrh otopné soustavy s tepelným čerpadlem vzduch-voda v kombinaci s bivalentním zdrojem / Design of a space heating system with an air-water heat pump and bivalent heat sourceSkočík, Lukáš January 2015 (has links)
The thesis is engaged in complete reconstruction of a heat system of a family house with higher heat loss, i.e. heat source, piping and radiators. As a heat source is chosen air-water heat pump. Heat system is designed with panel radiators with regard to minimum building interventions. A required power for hot water heating is calculated and selected a heat pump from suitable power range in combination with storage tank with hot water tank. The bivalent point is determined, as backup source are heating elements installed in storage tank. Drawings and circuit diagrams with safety elements are attached. In the end is calculation of estimated return.
|
45 |
Plavecký areál v Humpolci / The swimming centre in HumpolecKubíčková, Žaneta January 2016 (has links)
The diploma thesis is concerned with the swimming pool compound which is situated in the area of the Czech-Moravian Highlands, in the town Humpolec and it contains the complete documentary materials (documentation) for the execution of the project, fire safety solution to the building with respect to building physics, structural assess of wooden constructions and air- conditioning of the swimming hall. In the swimming compound there is a swimming hall with five swimming pools with the total water area of 605,4 m2 (swimming pool, the swimming pool for non-swimmers, relaxing swimming pool, whirpool, wading pool) and other additional services – four saunas with bar, massages,solarium and two buffets. The capacity of the swimming hall is 286 persons, the capacity of the whole compound is 418 persons. As for the shape of the building, it is designed as five rectangulars of different heights embedded into each other. Under the part of the swimming centre there is a basement and its external ground plan size is 61,33m*52,83. The basement serves as utility rooms of the whole building. The load-bearing construction of the swimming hall is designed using beam girders and pillars, made of glued laminated timber. In the rest of the building there is a brick construction system. Around the swimming hall there is a glass fronted facade.
|
46 |
Konstrukce sila na cukr / Sugar storage tankKotík, Libor January 2015 (has links)
The matter of this thesis is static design and examination of prestressed storage tank to 50000 tons of sugar. Computational model of the steel roof structure is processed and its effect on the silos. Loads is provided of sugar. Optimal design is performed and assessment ultimate and serviceability limit state reinforced concrete and prestressing horizontal silo wall including local load. Next, it is performed the design of a reinforced concrete of the plane bed and column and assessment at the ultimate limit state. The thesis is also drawing documentation, technical report and visualization of construction process. The aim of this work is to the design of the main components based on the required storage capacity tank, mechanical properties of the stored material and technical amenities.
|
47 |
Analysis of a novel thermoelectric generator in the built environmentLozano, Adolfo 05 October 2011 (has links)
This study centered on a novel thermoelectric generator (TEG) integrated into the built environment. Designed by Watts Thermoelectric LLC, the TEG is essentially a novel assembly of thermoelectric modules whose required temperature differential is supplied by hot and cold streams of water flowing through the TEG. Per its recommended operating conditions, the TEG nominally generates 83 Watts of electrical power. In its default configuration in the built environment, solar-thermal energy serves as the TEG’s hot stream source and geothermal energy serves as its cold stream source. Two systems-level, thermodynamic analyses were performed, which were based on the TEG’s upcoming characterization testing, scheduled to occur later in 2011 in Detroit, Michigan.
The first analysis considered the TEG coupled with a solar collector system. A numerical model of the coupled system was constructed in order to estimate the system’s annual energetic performance. It was determined numerically that over the course of a sample year, the solar collector system could deliver 39.73 megawatt-hours (MWh) of thermal energy to the TEG. The TEG converted that thermal energy into a net of 266.5 kilowatt-hours of electricity in that year. The second analysis focused on the TEG itself during operation with the purpose of providing a preliminary thermodynamic characterization of the TEG. Using experimental data, this analysis found the TEG’s operating efficiency to be 1.72%.
Next, the annual emissions that would be avoided by implementing the zero-emission TEG were considered. The emission factor of Michigan’s electric grid, RFCM, was calculated to be 0.830 tons of carbon dioxide-equivalent (CO2e) per MWh, and with the TEG’s annual energy output, it was concluded that 0.221 tons CO2e would be avoided each year with the TEG. It is important to note that the TEG can be linearly scaled up by including additional modules. Thus, these benefits can be multiplied through the incorporation of more TEG units.
Finally, the levelized cost of electricity (LCOE) of the TEG integrated into the built environment with the solar-thermal hot source and passive ground-based cold source was considered. The LCOE of the system was estimated to be approximately $8,404/MWh, which is substantially greater than current generation technologies. Note that this calculation was based on one particular configuration with a particular and narrow set of assumptions, and is not intended to be a general conclusion about TEG systems overall. It was concluded that while solar-thermal energy systems can sustain the TEG, they are capital-intensive and therefore not economically suitable for the TEG given the assumptions of this analysis. In the end, because of the large costs associated with the solar-thermal system, waste heat recovery is proposed as a potentially more cost-effective provider of the TEG’s hot stream source. / text
|
48 |
Kondenzační technika a odvody spalin / Condensing technology and flue gasMüller, Jan January 2014 (has links)
This thesis is developed as a proposal for heating for a primary school and kindergarten in the region of Brno-countryside. For the insulated building, a combination of heating and air-conditioning is proposed. The concept is designed so that the air-conditioning preheats the exterior air and the heating system warms the incoming air to a comfortable temperature. For the required thermal performance, sources of heat (for gas and pellets) and a layout solution for the boiler room is designed. Drainage of combustion products is proposed for both solutions. The project solution is per the extent of the construction permit. The theoretical part is linked with the practical part through the condensation boilers, their function and division, and drainage of combustion products. The experiment for the given topic was conducted on the drainage of combustion products. The pressure loss of the reverse knob was determined in relation to the flow rate of air in the condensation boilers as this loss is essential in assessing the drainage of combustion products.
|
49 |
Sportovní a kulturní areál, Otradov / Sports and cultural centre, OtradovMyška, Jan January 2016 (has links)
The subject of this diploma thesis is the preparation of project documentation for the implementation of new sports and cultural centre Otradov. The dominant feature of the complex objects stands and multipurpose hall. The building is architecturally designed with an effort to fit in too much of rural architecture. Multipurpose hall has two floors, one third roofed flat roof, two-thirds of the roof ridge. The core system is aerated concrete blocks. The building is two-storey grandstand with the carrier deck. Roofing is solved by means of broken wooden beams. Sanitary facilities is dealt wall system and roofed shed roof. Athletics track, the surface of the polyurethane mixture designed for sports.
|