• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modélisation et simulation d'un bioréacteur à membranes immergées pour le traitement des eaux usées urbaines et hospitalières / Modelling and simulation of a Submerged Membrane Bioreactor for the treatment of urban and hospital wastewater.

González Hernández, Yusmel 20 December 2018 (has links)
Dans cette thèse, la modélisation d'un bioréacteur à membranes immergées (BaMI) et son évaluation avec des valeurs expérimentales de BaMI à l'échelle du banc et à l'échelle pilote pour le traitement des effluents résiduels urbains et hospitaliers, ont été étudiées respectivement. L'objectif principal de ce travail était de développer un nouveau modèle intégré plus phénoménologique pour la description du fonctionnement de ces systèmes. A cet effet, un nouveau modèle biologique a été développé en utilisant le modèle de boues activés 3 (ASM3 du l’anglais activated sludge model) et en tenant en compte la croissance et le stockage de substrat simultané, et la production de substances polymères extracellulaires solubles et liées, qui, conjointement avec des solides en suspension totales ont été les principales variables de lien avec le nouveau modèle de colmatage de la membrane, en tenant compte de l'influence de ces substances sur la porosité du gâteau. Une nouvelle procédure d'identification des paramètres pour la calibration en prenant en compte leurs influence sur le modèle et leur incertitude a été développé. Cette procédure a permis de calibrer et de valider avec succès les nouveaux modèles développés, en utilisant les données des systèmes étudiés. Parallèlement, une nouvelle méthodologie a été développée pour le fractionnement de la matière carboné selon les modèles ASM en tenant compte du phénomène de stockage du substrat. Enfin, une étude de la sensibilité paramétrique a été réalisé, où le modèle intégré a répondu de manière adéquate aux variations des principales variables qui influent sur le colmatage de la membrane, avec une élevée correspondance entre la plupart des cas et ce qui a été rapporté dans la littérature, mettant en évidence une fois de plus le caractère phénoménologique et la validité du nouveau modèle développé. / This thesis presents the modelling of a submerged membrane bioreactor (SMBR) using experimental values coming from SMBR at bench and pilot scale, for the treatment of urban and hospital wastewater respectively. The main objective of this work was to develop a global model integrating a biological model and a model for membrane fouling, with upgraded precision, consistency and calibration in the description of the functioning of these systems. For this, concerning the biological model, an evolution of the Activated Sludge Model 3 (ASM3), including the simultaneous growth and substrate storage, and the bound and soluble extracellular polymeric substances (EPS) production was proposed. The concentration of these EPS joined to those of the total suspended solids (TSS) are the variables transmitted to the new version of the membrane fouling model. This last one can take into account the influence of these substances in the cake porosity. A new procedure was developed to calibrate the parameters taking into account their influence on the model and their uncertainty. This procedure used the data obtained on experimental SMBR and respirometry. It allowed the calibration and successful validation of the developed model. At the same time, a methodology was adapted for the carbon material fractionation according to the ASM models taking into account the phenomenon of substrate storage. Finally, a parametric sensitivity study was conducted, where the global model achieved to respond adequately to the perturbations of the main variables that influence on the membrane fouling process. The high correspondence obtained between numerical and experimental results, as well as the ability of the model to explain most of the cases reported in the literature, evidence the relevance of phenomena considered in the model. Thus, the developed model is justified and the interest of the phenomenological feature of the model is highlighted.
2

Aération pour le décolmatage dans les bioréacteurs à membranes immergées pour le traitement des eaux usées : impact sur le milieu biologique et la filtration / Aeration for fouling limitation in submerged membrane bioreactors for wastewater treatment : impact on biological media and filtration

Braak, Etienne 08 November 2012 (has links)
Cette étude présente les travaux réalisés pour comprendre l'effet de l'aération sur le milieu biologique et sur la filtration dans les bioréacteurs à membranes immergées pour une gamme de paramètres opératoires proche de celles utilisées sur stations réelles. Notre démarche fait le lien entre paramètres opératoires (débit d'aération), hydrodynamique à l'échelle macroscopique (tailles et vitesses de bulles), hydrodynamique à l'échelle locale (contraintes de cisaillement) et propriétés du milieu biologique (taille de flocs et substances polymériques extracellulaires solubles). De moins bonnes performances de filtration à plus forte aération pourraient être expliquées par une plus grande déstructuration des boues sur le court terme. Par ailleurs tout effet d'évolution des boues sur le long terme en fonction des conditions d'aération a été écarté. / This work contributes to the knowledge on aeration for fouling prevention in submerged membrane bioreactors, which represents a great part of energy consumption of the process. More precisely it aims at estimating the impact of aeration on mixed liquor properties for operational parameters range close to those used in full scale plants. Our study links operational parameters (airflow rate), hydrodynamics at macroscopic scale (bubble sizeand velocity), hydrodynamics at local scale (shear stresses), biological media properties (floc size and soluble extracellular polymeric substances), and filtration performance (transmembrane pressure variations). Hydrodynamics characterisation of two phase flow in membrane module enabled to highlight differences between air/water and air/sludge hydrodynamics with 15-25 % lower bubble velocities in sludge but one order of magnitude higher shear stress (maximal values of 10 Pa). Controlled breakdown of biological media was performed by imposing constant shear stress (range 0,1-10 Pa) to mixed liquor samples. Increase of shear induced a decrease of floc size, and soluble extracellular polymeric substances release. The comparison with shear value obtained by simulation showed that stresses induced by aeration were in the range of mixed liquor destructuration. A pilot campaign showed that wastewater had a stronger impact on the long term on mixed liquor properties, and thus filtration performances, than aeration. However higher transmembrane pressure increase rate observed on pilot for higher airflow at similar wastewater quality could be explained by stronger breakage of biological agregates on short term
3

Efeito das condições hidrodinâmicas no desempenho de um biorreator com membranas submersas em pressão constante

Cadore, Ígor Renz January 2015 (has links)
O processo de Biorreatores com Membranas (BRM) foi desenvolvido no final da década de 1960, consistindo em um sistema que associa o tratamento biológico de efluentes com o mecanismo de separação por membranas, e apresenta vantagens com relação ao tratamento convencional, tais como maior eficiência de tratamento e um menor espaço físico de instalação para a mesma capacidade de tratamento. O fenômeno de incrustação das membranas (em inglês, fouling) representa a principal limitação desse processo, de modo que uma das condições operacionais mais importantes na prevenção da incrustação em um sistema BRM Submerso (BRMS) é a vazão de aeração. Diante desta situação, o objetivo do trabalho consiste em avaliar os efeitos das condições hidrodinâmicas no desempenho do processo, tais como vazão de aeração, densidade de empacotamento do módulo de membranas e geometria dos aeradores. O sistema utilizado no trabalho consistiu em um BRMS automatizado, operando em pressão constante e de forma contínua, durante um período de 4 dias. Os módulos foram construídos com membranas poliméricas de microfiltração do tipo fibra oca, cujo material foi a poli(éter)-imida (PEI). Três diferentes vazões de aeração foram estudadas (2, 5 e 8 L.min-1), mostrando, a partir dos resultados, que existe uma vazão de aeração limite benéfica ao sistema e que, acima deste valor, um melhor desempenho não pode ser atingido, inclusive, podendo prejudicá-lo. Para o sistema de estudo, a vazão de 5 L.min-1 apresentou o melhor desempenho, seguido de 8 e 2 L.min-1. O estudo da densidade de empacotamento do módulo mostrou que esta é uma variável que também exerce influência no desempenho do processo de BRMS. Módulos com dois diferentes diâmetros foram testados (2,54 cm e 1,91 cm); o melhor resultado foi observado no módulo de maior diâmetro. A menor densidade de empacotamento resulta em um maior espaçamento entre as fibras, provocando uma aeração mais homogênea no interior do feixe de membranas. As duas geometrias de aeração testadas (Modo 1 e Modo 2) apresentaram resultados semelhantes de fluxo permeado, indicando que o Modo 2 de aeração não melhorou o desempenho do processo como se esperava. A maior homogeneidade de aeração no interior de feixe, a partir de aeradores construídos com as próprias fibras, não foi atingida, mostrando que um novo projeto de aeradores deve ser estudado. Em todas as condições hidrodinâmicas testadas, a eficiência do tratamento foi verificada, uma vez que a remoção de matéria orgânica para COT e DQO foi de 96% e 93%, respectivamente. Propriedades do permeado, como condutividade elétrica, pH e turbidez foram mensuradas, apresentando variações menores que as medidas do efluente, revelando a capacidade que o sistema apresenta em suportar as variações na corrente de alimentação. / The Membrane Bioreactor (MBR) process was developed in the late 1960. The system consists in a combination of biological process and membrane separation mechanism, and the advantages with respect of conventional treatment are the higher treatment efficiency and a smaller area of installation for the same treatment capacity. The main limitation of this process is the membrane fouling, in a way that air flow rate represents an important operating condition to prevent the fouling formation in Submerged Membrane Bioreactors (SMBR). In this sense, the aim of this work is to evaluate the effects of hydrodynamic conditions on process performance, such as air flow rate, packing density of the membrane module and aeration geometry. The system used consists in a pilot-scale SMBR, which operates at constant pressure and continuous mode during a period of 4 days. The modules were built with hollow fiber polymeric microfiltration membrane and the material is poly(ether)imide (PEI). For the three different air flow rates studied (2, 5 and 8 L.min-1), results showed there is a limit value for this parameter, in which above this value a better performance will not be obtained, even can be worse. The air flow rate of 5 L.min-1 presented the best performance, followed by 8 and 2 L.min-1. The module packing density study for two diameters (0.75 and 1 inch), the best result was observed in the larger diameter module, because lower packing density causes more space between fibres, increasing the aeration homogeneity inside de fibre bundle. Both aeration geometry tested showed similar permeate flows, indicating the different geometry used did not affect the performance process. The aerators constructed with the hollow fibers did not promote aeration homogeneity inside the bundle, and new aeration geometry must be projected. For all hydrodynamics conditions, the system treatment was efficient in removing organical matter, since the removal for TOC and COD was 96% and 93%, respectively. Permeate properties such as electrical conductivity, pH and turbidity measurements presented minor variations than effluent properties measurements, showing the system capacity to withstand with feed stream variations.
4

Efeito das condições hidrodinâmicas no desempenho de um biorreator com membranas submersas em pressão constante

Cadore, Ígor Renz January 2015 (has links)
O processo de Biorreatores com Membranas (BRM) foi desenvolvido no final da década de 1960, consistindo em um sistema que associa o tratamento biológico de efluentes com o mecanismo de separação por membranas, e apresenta vantagens com relação ao tratamento convencional, tais como maior eficiência de tratamento e um menor espaço físico de instalação para a mesma capacidade de tratamento. O fenômeno de incrustação das membranas (em inglês, fouling) representa a principal limitação desse processo, de modo que uma das condições operacionais mais importantes na prevenção da incrustação em um sistema BRM Submerso (BRMS) é a vazão de aeração. Diante desta situação, o objetivo do trabalho consiste em avaliar os efeitos das condições hidrodinâmicas no desempenho do processo, tais como vazão de aeração, densidade de empacotamento do módulo de membranas e geometria dos aeradores. O sistema utilizado no trabalho consistiu em um BRMS automatizado, operando em pressão constante e de forma contínua, durante um período de 4 dias. Os módulos foram construídos com membranas poliméricas de microfiltração do tipo fibra oca, cujo material foi a poli(éter)-imida (PEI). Três diferentes vazões de aeração foram estudadas (2, 5 e 8 L.min-1), mostrando, a partir dos resultados, que existe uma vazão de aeração limite benéfica ao sistema e que, acima deste valor, um melhor desempenho não pode ser atingido, inclusive, podendo prejudicá-lo. Para o sistema de estudo, a vazão de 5 L.min-1 apresentou o melhor desempenho, seguido de 8 e 2 L.min-1. O estudo da densidade de empacotamento do módulo mostrou que esta é uma variável que também exerce influência no desempenho do processo de BRMS. Módulos com dois diferentes diâmetros foram testados (2,54 cm e 1,91 cm); o melhor resultado foi observado no módulo de maior diâmetro. A menor densidade de empacotamento resulta em um maior espaçamento entre as fibras, provocando uma aeração mais homogênea no interior do feixe de membranas. As duas geometrias de aeração testadas (Modo 1 e Modo 2) apresentaram resultados semelhantes de fluxo permeado, indicando que o Modo 2 de aeração não melhorou o desempenho do processo como se esperava. A maior homogeneidade de aeração no interior de feixe, a partir de aeradores construídos com as próprias fibras, não foi atingida, mostrando que um novo projeto de aeradores deve ser estudado. Em todas as condições hidrodinâmicas testadas, a eficiência do tratamento foi verificada, uma vez que a remoção de matéria orgânica para COT e DQO foi de 96% e 93%, respectivamente. Propriedades do permeado, como condutividade elétrica, pH e turbidez foram mensuradas, apresentando variações menores que as medidas do efluente, revelando a capacidade que o sistema apresenta em suportar as variações na corrente de alimentação. / The Membrane Bioreactor (MBR) process was developed in the late 1960. The system consists in a combination of biological process and membrane separation mechanism, and the advantages with respect of conventional treatment are the higher treatment efficiency and a smaller area of installation for the same treatment capacity. The main limitation of this process is the membrane fouling, in a way that air flow rate represents an important operating condition to prevent the fouling formation in Submerged Membrane Bioreactors (SMBR). In this sense, the aim of this work is to evaluate the effects of hydrodynamic conditions on process performance, such as air flow rate, packing density of the membrane module and aeration geometry. The system used consists in a pilot-scale SMBR, which operates at constant pressure and continuous mode during a period of 4 days. The modules were built with hollow fiber polymeric microfiltration membrane and the material is poly(ether)imide (PEI). For the three different air flow rates studied (2, 5 and 8 L.min-1), results showed there is a limit value for this parameter, in which above this value a better performance will not be obtained, even can be worse. The air flow rate of 5 L.min-1 presented the best performance, followed by 8 and 2 L.min-1. The module packing density study for two diameters (0.75 and 1 inch), the best result was observed in the larger diameter module, because lower packing density causes more space between fibres, increasing the aeration homogeneity inside de fibre bundle. Both aeration geometry tested showed similar permeate flows, indicating the different geometry used did not affect the performance process. The aerators constructed with the hollow fibers did not promote aeration homogeneity inside the bundle, and new aeration geometry must be projected. For all hydrodynamics conditions, the system treatment was efficient in removing organical matter, since the removal for TOC and COD was 96% and 93%, respectively. Permeate properties such as electrical conductivity, pH and turbidity measurements presented minor variations than effluent properties measurements, showing the system capacity to withstand with feed stream variations.
5

Efeito das condições hidrodinâmicas no desempenho de um biorreator com membranas submersas em pressão constante

Cadore, Ígor Renz January 2015 (has links)
O processo de Biorreatores com Membranas (BRM) foi desenvolvido no final da década de 1960, consistindo em um sistema que associa o tratamento biológico de efluentes com o mecanismo de separação por membranas, e apresenta vantagens com relação ao tratamento convencional, tais como maior eficiência de tratamento e um menor espaço físico de instalação para a mesma capacidade de tratamento. O fenômeno de incrustação das membranas (em inglês, fouling) representa a principal limitação desse processo, de modo que uma das condições operacionais mais importantes na prevenção da incrustação em um sistema BRM Submerso (BRMS) é a vazão de aeração. Diante desta situação, o objetivo do trabalho consiste em avaliar os efeitos das condições hidrodinâmicas no desempenho do processo, tais como vazão de aeração, densidade de empacotamento do módulo de membranas e geometria dos aeradores. O sistema utilizado no trabalho consistiu em um BRMS automatizado, operando em pressão constante e de forma contínua, durante um período de 4 dias. Os módulos foram construídos com membranas poliméricas de microfiltração do tipo fibra oca, cujo material foi a poli(éter)-imida (PEI). Três diferentes vazões de aeração foram estudadas (2, 5 e 8 L.min-1), mostrando, a partir dos resultados, que existe uma vazão de aeração limite benéfica ao sistema e que, acima deste valor, um melhor desempenho não pode ser atingido, inclusive, podendo prejudicá-lo. Para o sistema de estudo, a vazão de 5 L.min-1 apresentou o melhor desempenho, seguido de 8 e 2 L.min-1. O estudo da densidade de empacotamento do módulo mostrou que esta é uma variável que também exerce influência no desempenho do processo de BRMS. Módulos com dois diferentes diâmetros foram testados (2,54 cm e 1,91 cm); o melhor resultado foi observado no módulo de maior diâmetro. A menor densidade de empacotamento resulta em um maior espaçamento entre as fibras, provocando uma aeração mais homogênea no interior do feixe de membranas. As duas geometrias de aeração testadas (Modo 1 e Modo 2) apresentaram resultados semelhantes de fluxo permeado, indicando que o Modo 2 de aeração não melhorou o desempenho do processo como se esperava. A maior homogeneidade de aeração no interior de feixe, a partir de aeradores construídos com as próprias fibras, não foi atingida, mostrando que um novo projeto de aeradores deve ser estudado. Em todas as condições hidrodinâmicas testadas, a eficiência do tratamento foi verificada, uma vez que a remoção de matéria orgânica para COT e DQO foi de 96% e 93%, respectivamente. Propriedades do permeado, como condutividade elétrica, pH e turbidez foram mensuradas, apresentando variações menores que as medidas do efluente, revelando a capacidade que o sistema apresenta em suportar as variações na corrente de alimentação. / The Membrane Bioreactor (MBR) process was developed in the late 1960. The system consists in a combination of biological process and membrane separation mechanism, and the advantages with respect of conventional treatment are the higher treatment efficiency and a smaller area of installation for the same treatment capacity. The main limitation of this process is the membrane fouling, in a way that air flow rate represents an important operating condition to prevent the fouling formation in Submerged Membrane Bioreactors (SMBR). In this sense, the aim of this work is to evaluate the effects of hydrodynamic conditions on process performance, such as air flow rate, packing density of the membrane module and aeration geometry. The system used consists in a pilot-scale SMBR, which operates at constant pressure and continuous mode during a period of 4 days. The modules were built with hollow fiber polymeric microfiltration membrane and the material is poly(ether)imide (PEI). For the three different air flow rates studied (2, 5 and 8 L.min-1), results showed there is a limit value for this parameter, in which above this value a better performance will not be obtained, even can be worse. The air flow rate of 5 L.min-1 presented the best performance, followed by 8 and 2 L.min-1. The module packing density study for two diameters (0.75 and 1 inch), the best result was observed in the larger diameter module, because lower packing density causes more space between fibres, increasing the aeration homogeneity inside de fibre bundle. Both aeration geometry tested showed similar permeate flows, indicating the different geometry used did not affect the performance process. The aerators constructed with the hollow fibers did not promote aeration homogeneity inside the bundle, and new aeration geometry must be projected. For all hydrodynamics conditions, the system treatment was efficient in removing organical matter, since the removal for TOC and COD was 96% and 93%, respectively. Permeate properties such as electrical conductivity, pH and turbidity measurements presented minor variations than effluent properties measurements, showing the system capacity to withstand with feed stream variations.

Page generated in 0.0752 seconds