• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 95
  • 95
  • 74
  • 64
  • 34
  • 31
  • 25
  • 24
  • 14
  • 14
  • 14
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo comparativo do vidro bioativo e osso autógeno em aumento do assoalho de seios maxilares de humanos / Comparative study of bioactive glass and autogenous bone graft in human maxillary sinus augmentation

Pereira, Rodrigo dos Santos [UNESP] 19 July 2016 (has links)
Submitted by RODRIGO DOS SANTOS PEREIRA null (rd2502@yahoo.com.br) on 2016-09-02T13:14:45Z No. of bitstreams: 1 Tese Rodrigo.pdf: 108582918 bytes, checksum: 2c7b303850ee3479eadff15a0275764a (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: No campo “Versão a ser disponibilizada online imediatamente” foi informado que seria disponibilizado o texto completo porém no campo “Data para a disponibilização do texto completo” foi informado que o texto completo deverá ser disponibilizado apenas 6 meses após a defesa. Caso opte pela disponibilização do texto completo apenas 6 meses após a defesa selecione no campo “Versão a ser disponibilizada online imediatamente” a opção “Texto parcial”. Esta opção é utilizada caso você tenha planos de publicar seu trabalho em periódicos científicos ou em formato de livro, por exemplo e fará com que apenas as páginas pré-textuais, introdução, considerações e referências sejam disponibilizadas. Se optar por disponibilizar o texto completo de seu trabalho imediatamente selecione no campo “Data para a disponibilização do texto completo” a opção “Não se aplica (texto completo)”. Isso fará com que seu trabalho seja disponibilizado na íntegra no Repositório Institucional UNESP. Por favor, corrija esta informação realizando uma nova submissão. Agradecemos a compreensão. on 2016-09-05T20:04:15Z (GMT) / Submitted by RODRIGO DOS SANTOS PEREIRA null (rd2502@yahoo.com.br) on 2016-09-13T00:17:32Z No. of bitstreams: 1 Tese Rodrigo.pdf: 108582918 bytes, checksum: 2c7b303850ee3479eadff15a0275764a (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-13T14:30:15Z (GMT) No. of bitstreams: 1 pereira_rs_dr_arafo.pdf: 108582918 bytes, checksum: 2c7b303850ee3479eadff15a0275764a (MD5) / Made available in DSpace on 2016-09-13T14:30:15Z (GMT). No. of bitstreams: 1 pereira_rs_dr_arafo.pdf: 108582918 bytes, checksum: 2c7b303850ee3479eadff15a0275764a (MD5) Previous issue date: 2016-07-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A deficiência óssea vertical do seio maxilar impossibilita a instalação de implantes dentais necessários para a reabilitação protética contudo, técnicas cirúrgicas para a elevação da membrana sinusal e o uso dos biomateriais para enxertia óssea permitiram alterar esta condição. O ósseo autógeno é considerado o mais previsível e o padrão ouro para tal finalidade porém, biomateriais como o vidro bioativo, amplamente utilizado na odontologia, permitem substituí-lo. O objetivo deste estudo foi avaliar formação óssea, o comportamento celular e a taxa de reabsorção do vidro bioativo em 2 proporções: puro (grupo 1); adicionado ao osso autógeno 1:1 (grupo 2), comparando com o osso autógeno (grupo 3) em seios maxilares de humanos. Com 15 dias de operados os pacientes realizaram um tomografia computadorizada (TC) cone beam para determinar o volume inicial do enxerto (T1). Após 6 meses uma nova TC foi realizada determinando o volume ósseo final (T2) e também, a coleta das biópsias com a instalação simultânea de implantes dentais. As amostras foram divididas em 3 áreas: leito, intermediária e apical onde foram avaliadas a histomorfometria e imunomarcações para Runx2, VEGF, osteocalcina e TRAP. No grupo 1 os resultados foram de 42.6%, 44.5% e 48% de formação óssea no leito, intermediária e apical respectivamente. No grupo 2 as taxas encontradas foram de 36.6% no leito, 33.2% na intermediária e 45.8% na apical. No grupo 3 foi de 34.4% para o leito, 35.0 na intermediária e 42.0% na apical. (p>0.05) Os 3 grupos apresentaram-se com comportamento semelhante nas imunomarcações realizadas mostrando estar maturado e calcificado o suficiente para receber implantes dentais. As taxas de reabsorção também mostraram-se semelhantes com 44.2% para o grupo 1, 37.9% para o grupo 2 e 45.7% no grupo 3. (p>0.05) Assim, podemos concluir que o vidro bioativo possui resultados equiparados ao osso autógeno. / Vertical bone deficit due maxillary sinus pneumatization forbid the dental implants placement required for prosthetic rehabilitation however, surgical techniques to elevate maxillary sinus membrane and studies about biomaterials, allows repair these situation. Autogenous bone graft is considered the most predictable and the gold standard for this nevertheless, biomaterials as bioactive glass, has been widely used in dental surgery and allows substitute it. The aim of this study was evaluate the bone formation, the cellular behavior and the resorption rates of bioactive glass in 2 proportions: pure (group 1); add to autogenous bone graft (group 3), comparing then with autogenous bone graft in human maxillary sinus. Post-operative cone beam computed tomography (CT) was used to measure the initial graft volume after 15 days (T1). Six months later, another CT was performed to evaluate the final graft volume (T2) and determine the graft resorption rate and the harvest of biopsies with dental implants placement simultaneously. The samples were divided in 3 areas: bed, intermediately and apical which were evaluated to histomorphometric and immunostaining to Runx2, VEGF, osteocalcin and TRAP. In group 1 the bone formation were 42.6%, 44.5 and 48.0% for bed, intermediately and apical respectively. In group 2 the rates were 36.6% in bed, 33.2% in intermediately and 45.8% in apical. In group 3 were 34.4% in bed, 35.0% in intermediately and 42.0% in apical. (p>0.05) the 3 groups had the same behavior for the 4 proteins showing be matured and calcified to receive dental implants. The resorption rates were similar for the 3 groups with 44.2% % for group 1, 37.9% for group 2 and 45.7% for group 3. (p>0.05) In conclusion, the bioactive glass is a good substitute to autogenous bone graft in both proportions evaluated.
92

Análise comparativa de diferentes substitutos ósseos sintéticos microporosos em calvária de coelhos / Comparative analysis of different Synthetic microporous bone substitutes in rabbit calvaria

Levandowski Junior, Nelson 14 July 2014 (has links)
Made available in DSpace on 2016-12-08T15:56:17Z (GMT). No. of bitstreams: 1 Resumo LEVANDOWSKI.pdf: 475369 bytes, checksum: 6234f28eabf60dbad017c95e2d659f76 (MD5) Previous issue date: 2014-07-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nanotechnology involves creation, manipulation and exploitation of materials at the nanoscale. This Science has led to research and development of new materials consisting of molecules, particles and/or grains in the nanometer scale. The Research Group in Biomaterials of UDESC develops studies in the field of nanotechnology and nanomaterials for more than a decade with the goal of developing nanostructured biomaterials with different characteristics of conventional biomaterials, capable of promoting early bone formation and contributes significantly within the bone healing and quality of life The first step of this Thesis research aimed to characterize six different granular microporous biomaterials divided into two groups. Group I was composed of hydroxyapatite (HAp), beta tricalcium phosphate (TCP), and biphasic calcium phosphate (BCP) at a concentration of 60% HAp and 40% TCP by volume. Group II consisted of three compositions of nanocomposites in hydroxyapatite matrix, with 5% by volume of the second nanometric phase, in the following compositions: HAp-SiO2n, HAp-TiO2n and HAp-Al2O3-αn. The results of the characterization were related to X-ray diffraction analysis (XRD), Fourier transformed infrared spectroscopy (FTIR), morphological and microstructural characterization, specific surface area, hydrostatic density and open porosity. After characterization studies, the calcium phosphate biomaterials and nanocomposites were used for simultaneous comparative analysis of bone formation in a method of guided bone augmentation in rabbit calvaria. Blood clot (C) and bovine hydroxyapatite BioOss® (HAP-BOV) served as control. The results of histomorphometric analysis demonstrated that the biomaterial HAp-SiO2 showed the highest amount of mineralized bone tissue after 45 days (39.07%), followed by HAp (36.92%), TCP (31.3%), BCP (31.2%), HAp-Al2O3 (28.88%), HAp-BOV (26.45%), HAp-TiO2 (15.92%) and C (3.6%). After 90 days, analysis was performed only for Group I and the 14 HAp biomaterial had the highest amount of mineralized bone tissue (49.46%), followed by BCP (41.5%), TCP (35.18%) and C (6.26%). The results of the characterization and in vivo studies showed that calcium phosphates HAp, TCP, BCP and nanocomposite HAp-SiO2 were biocompatible and do not induced inflammatory tissue reactions. Their microstructural characteristics, with lower grain than 800nm and interconnected microporosity above 25%, provided better performance of bone formation in relation to commercial biomaterial used as control. / A nanotecnologia envolve a criação, manipulação e exploração de materiais na escala nanométrica. Esta Ciência tem levado à investigação e ao desenvolvimento de novos materiais constituídos por moléculas, partículas e/ou grãos na escala do nanômetro. O Grupo de Pesquisa em Biomateriais da UDESC desenvolve pesquisas na área de nanotecnologia e nanomateriais há mais de uma década com o objetivo de desenvolver biomateriais nanoestruturados com características diferenciadas dos biomateriais convencionais, capazes de promover a neoformação óssea precoce e contribuir significativamente dentro dos processos de reparação tecidual e com a qualidade de vida. A primeira etapa deste trabalho de Tese teve por objetivo realizar a caracterização de seis diferentes biomateriais microporosos granulados, divididos em dois grupos. O grupo I foi composto pelos biomateriais hidroxiapatita (HAp), fosfato tricálcico beta (TCP) e fosfato de cálcio bifásico (BCP) na concentração de 60% HAp e 40% TCP em volume. O grupo II foi formado por três composições de biomateriais nanocompósitos em matriz de hidroxiapatita, a 5% em volume da segunda fase nanométrica, nas seguintes composições: HAp-SiO2n, HAp-TiO2n e HAp-Al2O3-n. Os resultados de caracterização obtidos relacionaram os dados referentes à análise por difratometria de raios X (DRX), espectroscopia de infravermelho com transformada de Fourier (FTIR), caracterização morfológica e microestrutural, área superficial, densidade hidrostática e porosidade aberta. Após a realização dos estudos de caracterização, os biomateriais fosfatos de cálcio e nanocompósitos foram utilizados para uma análise comparativa simultânea de formação óssea em um método de aumento ósseo guiado em calvária de coelhos. Como controle foram utilizados o coágulo sanguíneo (C) e a hidroxiapatita bovina BioOss® (HAP-BOV). Os resultados da análise histomorfométrica demonstraram que o biomaterial HAp-SiO2 apresentou a maior quantidade de tecido ósseo mineralizado aos 45 dias (39,07%), seguido da HAp (36,92%), TCP (31,3%), BCP (31,2%), HAp-Al2O3 (28,88%), HAp-BOV (26,45%), HAp-TiO2 (15,92%) e C (3,6%). A análise aos 90 dias foi realizada apenas para o grupo I e o biomaterial HAp apresentou a maior 12 quantidade de tecido ósseo mineralizado (49,46%), seguido por BCP (41,5%), TCP (35,18%) e C (6,26%). Os resultados obtidos dos estudos de caracterização e de formação óssea mostraram que os fosfatos de cálcio microporosos HAp, TCP, BCP e o nanocompósito microporoso HAp-SiO2 foram biocompatíveis e não induziram reações teciduais inflamatórias. Suas características microestruturais, com grãos inferiores a 800nm e microporosidade interconectada acima de 25%, proporcionaram um melhor desempenho de formação óssea em relação ao biomaterial comercial utilizado como controle.
93

Análise da utilização do osteoscafTM como substituto ósseo em cirurgia de levantamento de seio maxilar / Use of OsteoScaf™ in maxillary sinus augmentation

Camila Lopes Cardoso 04 March 2013 (has links)
Procedimentos de levantamento do seio maxilar têm sido realizados para aumentar o volume ósseo e promover a estabilidade do implante, na região posterior de maxilas severamente atrofiadas. Ao longo dos anos, resultados de vários estudos demonstraram que alguns substitutos ósseos podem suportar implantes em função, após o levantamento de seio maxilar, igual ou melhor quando utilizado o osso autógeno. Neste estudo, foi avaliado o comportamento de um substituto ósseo completamente biodegradável (OsteoScaf™) no modelo experimental de levantamento de seio maxilar em coelhos. Além disso, ele foi comparado com o osso autógeno e outros dois substitutos ósseos, não totalmente biodegradáveis, disponíveis comercialmente (Bio-Oss® e BoneCeramic®). Avaliação clínica, tomografia computadorizada por feixe cônico, microtomografia computadorizada, análises microscópicas e análise molecular, através da técnica de PCR, foram realizadas após 2, 4 e 8 semanas de cirurgia. O levantamento de seio maxilar utilizando o osso autógeno demonstrou maior reabsorção, ao longo do tempo, comparado aos substitutos ósseos, os quais revelaram maior neoformação óssea após 8, 4 e 2 semanas, respectivamente. O grupo Bio-Oss® apresentou maior neoformação óssea, ao longo do tempo, quando comparado aos grupos Osteoscaf™ e BoneCeramic®, os quais foram qualitativamente emelhantes. O grupo BoneCeramic® mostrou uma resposta celular de células gigantes até 8 semanas. Concluiu-se que os substitutos ósseos, neste estudo, obtiveram melhor desempenho do que o osso autógeno, e o OsteoScaf™ demonstrou maior reabsorção do que os outros grupos, em todos períodos. / Maxillary sinus augmentation procedures have been applied to increase bone volume and to promote stability of implants in the severely atrophied posterior maxilla. Over the years, the outcomes of several studies have demonstrated that some bone substitutes can support implants in function after sinus augmentation as well as, or better than those with autogenous bone. Our experimental model evaluated the behavior of a fully biodegradable bone substitute (OsteoScaf™) in a rabbit sinus lift procedure. We compared this with autogenous bone and other two available non-biodegradable bone substitutes (Bio-Oss® and BoneCeramic®). Clinical evaluation, Cone Beam Computed Tomography, Microcomputed Tomography, microscopic and molecular evaluation were used for data analysis at 2, 4 and 8 weeks after sinus augmentation. Autogenous bone was more resorbed over time than the other materials. All bone substitutes showed more bone formation at 8, 4 and 2 weeks, respectively. Bio-Oss® showed more bone formation/timepoint than Osteoscaf™ and Boneceramic®, which were similar. Boneceramic® showed a florid giant cell response up to 8 weeks. We concluded that the bone graft materials all performed better than autogenous bone and OsteoScaf™ showed comparative bone growth yet greater degradation than the other two materials.
94

Avaliação por meio da tomografia computadorizada de feixe cônico da disponibilidade óssea da sínfise mandibular

Gabriel Fiorelli Bernini 08 November 2013 (has links)
Introdução: As características anatômicas dos ossos maxilares e suas possíveis variações apresentam um grande interesse, pela crescente demanda por procedimentos cirúrgicos como cirurgias ortognáticas e colocação de implantes osseointegráveis. Nessa perspectiva, existe particular interesse em relação aos enxertos ósseos autógenos, considerando-se a necessidade crescente de sua aplicação associados aos implantes, naqueles indivíduos com reabsorções e defeitos ósseos. O conhecimento da anatomia e do conteúdo da área inter-forames mentuais e possíveis implicações clínicas são ainda controversos e pouco documentados. A tomografia computadorizada de feixe cônico (TCFC) possibilita a reformatação da imagem em três dimensões permitindo um estudo mais detalhado da região da sínfise mandibular. Objetivo: Avaliar as dimensões da sínfise mandibular para enxertia óssea, nas reformatações panorâmicas e parassagitais obtidas por TCFC. Material e Métodos: Foram determinadas: a distância inter-forames mentuais, a distância entre a cortical vestibular e a cortical lingual e a distância entre o ápice dos dentes anteriores inferiores e a base da mandíbula. Será avaliada também a presença de alças anteriores do nervo mentual e extensão anterior das mesmas nas duas reformatações. Utilizou-se 200 TCFC, de homens e mulheres adultos, proveniente dos arquivos de imagem do Departamento de Estomatologia da Faculdade de Odontologia de Bauru/USP. A visibilidade e as medições da sínfise mandibular foram avaliadas pela TCFC através da ferramenta de distância do i-CAT Vision Software nas reformatações panorâmica (RfPan) e parassagital (RfPsg) determinando assim suas medidas para realização de cirurgia para remoção de enxerto ósseo. Resultados: A média das medidas da distância inter-forames mentuais, para obter a largura da área doadora, foi de 42,27 mm; entre a cortical vestibular externa e a cortical lingual externa, para obter a espessura total da área doadora foi de 10,31 mm para o lado direito, 10,07 mm para o lado esquerdo e 10,5 mm para a linha média; entre a cortical vestibular interna e a cortical lingual interna, para obter a espessura do trabeculado medular da área doadora foi de 5,82 mm para o lado direito, 5,54 mm para o lado esquerdo e 5,93 mm para a linha média; entre o ápice dos dentes anteriores inferiores, preferencialmente os caninos, e a base da mandíbula, para obter a altura da área doadora foi de 13,03 mm para o lado direito, 12,87 mm para o lado esquerdo e 17,86 para a linha média. A alça anterior do forame mentual foi visualizada em 47 das 200 imagens de TCFC, ou 23,5% delas, sendo em 36 (18%) do lado direito e do lado esquerdo, 3 (1,5%) apenas do lado direito e 8 apenas do lado esquerdo (4%). A média das medidas da distância entre a alça anterior e a base da mandíbula foi de 7,02 mm para o lado direito e 6,73 mm para o lado esquerdo. Conclusões: A sínfise mandibular pode fornecer um volume de 632,51 mm3 (32,47 x 4,87 x 4 mm), quando utilizarmos as novas margens de segurança preconizadas, ou até 1.344,13 mm3 (32,47 x 7,87 x 5,26 mm), quando consideradas as margens de segurança previamente descritas. Esses valores mostram a disponibilidade óssea da sínfise mandibular como uma das principais opções para remoção de enxerto autógeno em reconstruções parciais dos maxilares. / Introduction: The anatomical characteristics of the maxillary bones and their possible variations present a great interest by increasing demand for surgical procedures such as orthognathic surgery and placement of osseointegrated implants. From this perspective, there is particular interest in relation to autogenous bone grafts, considering the growing need for their application associated with implants in those individuals with resorption and bone defects. The knowledge of the anatomy and content of the mental inter-foramina area and possible clinical implications are still controversial and poorly documented. Cone beam computed tomography (CBCT) allows reformatting of a three-dimensional image allowing a more detailed study of the mandibular symphysis region. Objective: To assess the dimensions of the mandibular symphysis for bone grafting in panoramic and parasagittal reconstructions obtained by CBCT. Material and Methods: Determined were: the mental inter-foramina distance, the distance between the buccal cortical and lingual cortical and the distance between the apex of the mandibular anterior teeth and the base of the mandibula. The presence of anterior loops of the mental nerve and anterior extension of the same in the two reconstructions will also be evaluated. Two hundred CBCT`s from adult men and women were utilized, obtained from the image files of the Department of Stomatology, Bauru School of Dentistry / USP. The visibility and measurements of the mandibular symphysis were evaluated by CBCT through the distance tool from the i-CAT Vision Software in panoramic (RfPan) and parasagittal (RfPsg) reconstructions, thus determining their measurements to perform surgery for the removal of the bone graft. Results: The average measurement of the mental inter-foramina distance, to obtain the width of the donor area was 42.27 mm between the outer buccal cortical and external lingual cortical, and to obtain the total thickness of the donor area was 10.31 mm to the right side, 10.07 mm to the left side and 10.5 mm to the midline; between the internal buccal cortical and internal lingual cortical to obtain the thickness of the trabecular medullary of the donor area was 5.82 mm to the right side, 5.54 mm to the left side and to 5.93 mm to the midline, between the apex of the anterior teeth, preferably canines and the base of the mandibula to obtain the height of the donor area was 13.03 mm to the right side, 12.87 mm to the left and 17.86 to the midline. The anterior loop of the mental foramen was visualized in 47 out of 200 CBCT images, or 23.5%, and in 36 (18%) of the right and left sides, 3 (1.5%) only on the right side and 8 only the left side (4%). The average measure of the distance between the anterior loop and the base of the mandibula is 7.02 mm to the right side and 6.73 mm to the left side. Conclusions: The mandibular symphysis can provide a volume of 632.51 mm3 (32.47 x 4.87 x 4 mm), when the new recommended safety margins are used, or until 1344.13 mm3 (32.47 x 7.87 x 5.26 mm), when considering the safety margins previously described. These values show the available bone of the mandibular symphysis as one of the main options for removal of the autogenous graft in partial maxillary reconstructions.
95

Desenvolvimento e caracterização de um cimento ósseo esponjoso para preenchimento de falhas ósseas. Análise morfométrica e ensaio mecânico / Development and characterization of a cancellous cement repair of bone defects. Morphometric analisys and mechanical testing

Bruno Cimatti 28 June 2012 (has links)
Introdução: O tratamento dos tumores ósseos benignos é frequentemente realizado por abordagem intralesional com curetagem do tumor e preenchimento da falha óssea com substâncias biológicas ou sintéticas. Entre as biológicas estão os vários tipos de enxertos e o maior representante das sintéticas é o cimento ósseo ou polimetilmetacrilato (PMMA). O uso do cimento ósseo compacto pode apresentar problemas devido à necrose térmica, ao afrouxamento asséptico, à incapacidade de remodelação e à elasticidade inadequada em relação ao osso normal. O desenvolvimento de um cimento ósseo esponjoso que atenda a estas demandas mecânicas e biológicas e que seja de fácil manipulação no ambiente cirúrgico tem estimulado alguns pesquisadores. Basicamente, é possível formar poros no interior do cimento por mistura de substâncias hidrossolúveis ou por reação química produtora de gás. Objetivo: Desenvolver e caracterizar fisicamente e mecanicamente um cimento ósseo com poros intercomunicantes de aspecto estrutural esponjoso. Material e métodos: A produção de cimento esponjoso foi realizada misturando-se o PMMA com bicarbonato de sódio e ácido cítrico. Foram confeccionados 90 corpos de prova com 40 mm de altura por 20 mm de diâmetro distribuídos em 6 grupos (n=15): G1 formado por cimento esponjoso em que antes da polimerização do cimento foram adicionados bicarbonato de sódio e ácido cítrico na proporção de 10% em relação ao componente sólido do cimento (polímero); G2 - cimento esponjoso na proporção de 20%; G3 - cimento esponjoso na proporção de 30%; G4 - cimento ósseo de PMMA compacto; G5 - formado por cimento de poliuretana de mamona (Bioósteo®) na proporção de 20%; G6 formado de corpos de prova cilíndricos de osso esponjoso extraído com trefina de côndilos tibiais proximais de bovinos. A qualidade do cimento esponjoso foi avaliada por macroscopia, cálculo de densidade, imersão em azul de metileno, tomografia computadorizada, microscopia eletrônica de varredura e ensaio mecânico de compressão. Resultados: A melhor forma de produção de cimento esponjoso foi pela mistura de PMMA e componentes efervescentes. O teste da imersão em azul de metileno mostrou que os G2 e G3 apresentaram melhor intercomunicabilidade. As análises com o microscópio eletrônico de varredura (MEV) mostraram uma ampla variação no tamanho e distribuição dos poros que medem de 50m a 3mm. Em relação aos ensaios mecânicos não houve diferenças significativas entres os grupos de cimento esponjoso G1, G2 e G3. Estes grupos apresentaram valores pouco inferiores aos do grupo G6 de osso esponjoso bovino. O grupo G4 (PMMA compacto) apresentou valores extremamente altos quando comparado ao osso esponjoso bovino e ao cimento esponjoso. O grupo G5 de cimento ósseo de mamona não atingiu os valores aceitáveis de resistência mecânica. Conclusão: Foi possível desenvolver um cimento esponjoso à base de polimetilmetacrilato pela mistura com os aditivos efervescentes, bicarbonato de sódio e ácido cítrico, que apresenta características físicas e mecânicas desejadas como substituto ósseo esponjoso nas curetagens para tratamento de tumores ósseos benignos. O cimento de mamona esponjoso na forma testada mostrou-se inadequado para os fins pretendidos. / Introduction: Benign bone tumors are usually treated by intralesional curettage. The bone defect may be filled with synthetic or biological substitutes. Polymetylmethacrylate (PMMA) is the most popular synthetic substitute and the solid form is associated to thermal necrosis, aseptic loosening, bone remodeling prevention and distinct elasticity. Research of porous cement that solves these drawbacks and can be molded intraoperatively has encouraged many authors. For surgical purposes, porosity can be achieved by mixing hydrosoluble substances or by gas-foaming reactions. Objective: Development and physical and mechanical characterization of a bone cement with interconnecting pores and cancellous bone like structural aspect. Methods: Porous cement was produced by adding the effervescent components sodium bicarbonate and citric acid to PMMA. Six groups of fifteen cylindrical samples (40 mm height, 20 mm diameter) were compared. G1, G2 and G3 groups consisted of porous cement specimens of PMMA with 10%, 20% and 30% of effervescent components respectively. G4 consisted of solid PMMA cement specimens. G5 group consisted of porous ricinic polyurethane cement (Bioósteo®) with 20% effervescent components specimens. The control group G6 consisted of bovine cancellous bone samples. The porous cements were characterized in terms of porosity, density, pore interconnectivity and compressive strength. Macroscopic evaluation and measuring, methylene blue immersion, Scanning Electron Microscopy (SEM), mechanical testing and a special computed tomography reading software were employed for these evaluations. Results: The pilot study showed that adding effervescent components to PMMA was the best solution for porous cement production. The methylene blue immersion test showed that G2 and G3 groups had better pore interconnection. Scanning electron microscopy (SEM) showed a wide variation in pore size, from 50m to 3mm, and pore distribution. No significant differences between G1, G2 and G3porous cement groups were found regarding to mechanical strength and Young Modulus. Cancellous bovine bone, G6, was slightly stronger and less elastic than these groups. This property is potentially beneficial considering osteointegration as a consequence of Wolfs law. Solid PMMA is extremely strength and inelastic. These properties do not match with cancellous bone. The porous ricinic polyurethane cement (Bioósteo®) is unacceptably weak. Conclusion: Porous cement was developed by adding effervescent components, sodium bicarbonate and citric acid, to polymethylmetacrylate. Physical and mechanical properties are very similar to cancellous bone. Further investigations to evaluate its bone substitute potential should be encouraged. The porous ricinic polyurethane cement (Bioósteo®) is inadequate these purpose.

Page generated in 0.065 seconds