• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação audiológica e quantificação da exposição ao ruído em profissionais do corpo de bombeiros

Taxini, Carla Linhares [UNESP] January 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2013Bitstream added on 2014-06-13T18:51:59Z : No. of bitstreams: 1 taxini_cl_me_mar.pdf: 994922 bytes, checksum: e166b3ee238a723adbb2ea5aaf4a6767 (MD5) / O bombeiro é um profissional que possui treino e equipamento adequado para desenvolver diversas tarefas como apagar incêndios, resgatar pessoas e fornecer assistência em desastres naturais, e dessa forma, estão constantemente expostos ao ruído. Tal exposição pode ocasionar a perda auditiva induzida pelo ruído (PAIR), que se caracteriza por uma perda insidiosa e cumulativa, do tipo neurossensorial. Sendo assim objetivou-se delinear o perfil audiológico dos bombeiros e mapear os diferentes ambientes acústicos a que estes profissionais se expõem. Participaram desse estudo 41 bombeiros que foram submetidos à anamnese audiológica, inspeção do conduto auditivo, audiometria tonal liminar, logoaudiometria, imitanciometria e emissões otoacústica evocadas por produto de distorção (EOAPD). Foram realizadas também as medições das exposições dos níveis de pressão sonora (NPS) dos equipamentos e nos ambientes do 10º Grupamento de Bombeiros da cidade de Marília-SP utilizando um audiodosímetro digital. Como resultado obteve-se 11 (27%) dos bombeiros com limiares tonais sugestivos de PAIR, no entanto, destes, apenas 4 (36%) foram bilaterais, 2 (18%) unilaterais com orelha contralateral não sugestiva de PAIR e 5 (46%) unilaterais com orelha contralateral normal. Nas amplitudes das EOAPD houve diferença significativa entre as orelhas normais e as orelhas sugestivas de PAIR nas frequências de 4 e 6 kHz à direita e 6 kHz à esquerda, e entre as orelhas normais e não sugestivas de PAIR em 2, 3 e 6 kHz à direita e em 1, 2, 3, 4, 6 e 8 kHz à esquerda. Houve correlação significativa entre os resultados das audiometrias tonais liminares e as EOAPD para as frequências de 2, 3, 4 e 6 kHz à direita e para 1, 2, 3, 4, 6, e 8 kHz à esquerda. No mapeamento sonoro as medições realizadas na Central de Operações dos Bombeiros Militares (COBOM) registraram nível equivalente... / The firefighter is a professional who has training and equipment to conduct various tasks such as putting out fires, rescue people and give assistance in the natural disaster, so they are constantly exposed to the noise. This exposure can lead to noise-induced hearing loss (NIHL), which is characterized by an insidious and cumulative sensorineural loss. The aim was trace the audiological profile of firefighters and to analyze the acoustic environments that these professionals are exposed. The study included 41 firefighters who were submitted to audiologic anamnesis, inspection of the external auditory canal, pure tone audiometry, speech audiometry, tympanometry and distortion product otoacoustic emissions (DPOAE). Were also carried out measurements the sound pressure levels of the equipment and environments in the 10th Fire Department in Marília-SP using a digital dosimeter. The result of this study showed 11 (27%) of firefighters had hearing thresholds suggestive of NIHL, however only 4 (36%) of these cases were suggestive of bilateral NIHL, 2 (18%) was unilateral with opposite ear not suggestive of NIHL, and 5 (46%) was unilateral with opposite normal ear. It was observed statistical difference in DPOAE the amplitudes of normal ears and of ears suggestive of NIHL in the frequencies of 4 and 6 kHz at the right ear and 6 kHz at the left ear, and between normal ears and the ears not suggestive of NIHL in 2, 3 and 6 kHz at the right and 1, 2, 3, 4, 6 and 8 kHz at the left ears. There was correlation between the results of pure tone audiometry and DPOAE in 2, 3, 4 and 6 kHz frequencies of right ears and 1, 2, 3, 4, 6, and 8 kHz of left ear. In the sound mapping, the measurements performed in the Operations Center of Military Firefighters recorded the equivalent noise level (Leq) was 79,35 dB(A) in the external environment and 92,37 dB(A) in the head-sets... (Complete abstract click electronic access below)
2

Análise dos níveis de ruído produzidos pelas canetas de alta rotação nas freqüências de bandas de oitavas e as atenuações dos protetores auriculares

Ferreira, Nelly Foster [UNESP] 07 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-07Bitstream added on 2014-06-13T18:31:53Z : No. of bitstreams: 1 ferreira_nf_me_araca.pdf: 683484 bytes, checksum: 2fa8b5c7c47d7b349064e3a92d49096b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O aumento das fontes produtoras de ruído tem prejudicado a qualidade de vida dos profissionais, acelerando a deterioração do aparelho auditivo, podendo causar lesões irreversíveis, dependendo da intensidade do ruído e do tempo de exposição. O objetivo do presente estudo foi analisar o nível de ruído de 3 marcas diferentes de instrumentos de alta rotação, e identificar qual será o menos lesivo ao profissional e, ainda, verificar as atenuações produzidas por protetores auriculares tipo plug de 4 diferentes marcas e indicar o de maior eficiência na prática profissional. O instrumento utilizado foi um medidor de nível sonoro, decibelímetro com filtro de banda de oitava e terça oitava. Foram feitas no total de 740 medições, sendo que os resultados dessas medições foram analisados juntamente com as atenuações em decibels nas freqüências de bandas de 1/1 oitavas das 4 marcas diferentes de protetores auriculares do tipo plug, disponíveis, atualmente, no mercado. Os resultados da aferição de ruído em média de 72,1dB para Caneta B; 79,8 dB para Caneta C e 80,8 dB Caneta A, não ultrapassam o limite de 85 dB, conforme a NR-15 da norma de Segurança e Medicina do Trabalho e, portanto, não sendo obrigatório o uso do protetor auditivo. No entanto todos os valores ficaram acima de 65 dB da norma NBR-10152 de conforto acústico. Em relação ao protetor auricular, pode-se observar que, a maior média apresentada foi da marca Pomp Plus (26,7 dB), seguido da Dura Plus Plug (25,6 dB), CO-MAXXI (24,8 dB) e 3M1270 (24,8 dB), no entanto, convém salientar que houve altos valores do desvio padrão nas atenuações em todas as freqüências. Conclui-se que o profissional deve adotar medias de comportamento preventivo, como o uso do protetor auricular, mesmo que não obrigatório, para evitar lesões auditivas ao longo de sua carreira. / The increase of the producing sources of noise has been harmful to the quality of professionals' life, speeding up the deterioration of the auditory device, it could be causing irreversible injuries, depending on the intensity of the noise and the exposition time. The objective of the present study was analyze the level of noise of 3 different marks of high speed handpieces, and to verify the attenuations produced for auditive protectors type plug of 4 different marks and to indicate the more efficiency in the practical professional. The instrument used was a sound level meter, with band of eighth filter. It had been made in the total of 740 measurements, being that the results of these measurements had been analyzed together with the attenuations in decibels in each frequency of the 4 different marks of auditive protectors, available, currently, in the market. The results of the measurements of noise in average of 72.1dB for high speed handpiece B, 79.8 dB for high speed handpiece C and 80.8 dB high speed handpiece A, and these values does not above 85 dB in accordance to NR-15 of the Security and Work Medicine Norms and does not obligate the use of auditive protector. However all the values had been above of 65 dB of the NBR-10152 norm of acoustic comfort. In relation to the auditive protector, it can be observed that, the presented average greater was of the mark Pomp Plus (26.7 dB), followed of Dura Plus Plug (25.6 dB), CO-MAXXI (24.8 dB) and 3M1270 (24.8 dB), however the standard deviation of the attenuations in all the frequencies is high values. It is concluded that the professional must adopt measured of preventive behavior, as the use of the auditive protector, exactly that not obligator, to prevent them about auditory injuries in all career.

Page generated in 0.1124 seconds