• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Comparação entre a radiografia panorâmica e a tomografia computadorizada de feixe cônico para avaliação de septos em seios maxilares

Haas, Letícia Fernanda January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-09-15T04:09:32Z (GMT). No. of bitstreams: 1 334015.pdf: 1357587 bytes, checksum: 2c6c5ab0c9d15f37baf1881a940b4f5f (MD5) Previous issue date: 2015 / Os septos são estruturas de osso cortical, localizados no interior dos seios maxilares, que dividem parcialmente estas estruturas. A presença do septo configura um obstáculo adicional na cirurgia de levantamento do assoalho do seio maxilar, pois aumenta o risco de perfuração da membrana sinusal assim como dificulta a visualização e o acesso adequados de toda a extensão do seio maxilar, o que pode causar um enxerto incompleto. Os exames mais utilizados para a avaliação de septo são a radiografia panorâmica e as reconstruções multiplanares da tomografia computadorizada de feixe cônico (TCFC). O objetivo deste estudo foi avaliar a capacidade diagnóstica da radiografia panorâmica, da reconstrução panorâmica da TCFC e das imagens transversais quando comparadas com a imagem axial em detectar a presença, localização e orientação do septo em seio maxilar. Para a análise da associação das variáveis foi utilizado o teste de chi quadrado ou exato de Fischer. O nível de significância adotado foi a < 0,05. Para o diagnóstico de presença ou ausência de septo a radiografia panorâmica (7,1%) e a reconstrução panorâmica da TCFC (4,2%) foram semelhantes à imagem axial, todavia as imagens transversais diferiram estatisticamente (12,1%). Em relação ao diagnóstico da localização do septo, a radiografia panorâmica (35%), a reconstrução panorâmica da TCFC (33,3%) e as imagens transversais (29,3%) foram diferentes estatisticamente da imagem axial. No diagnóstico da orientação do septo a radiografia panorâmica (1,4% ântero posterior 64,1% bucopalatal), a reconstrução panorâmica da TCFC (27,3% e 72,4% bucopalatal) e as imagens transversais (0,9% ínfero superior, 9,1% ântero posterior e 90,9% bucopalatal) diferiram estatisticamente da imagem axial. Conclui-se que, a radiografia panorâmica, a reconstrução panorâmica da TCFC e as imagens transversais não fornecem as informações necessárias para a localização e orientação de septo em seio maxilar.<br> / Abstract : Septa are cortical bone structures located within the maxillary sinuses, which partially divide these. The presence of the septum sets an additional obstacle in the maxillary sinus floor lifting surgery, which increases sinus membrane perforation risk and makes it difficult to view and adequately access the entire length of the maxillary sinus, which can cause an incomplete graft. The most common tests used for septum evaluation are panoramic radiograph and multiplanar reconstruction of cone beam computed tomography (CBCT). The objective of this study was to evaluate the diagnostic ability of panoramic radiography, panoramic reconstruction of CBCT and cross-sectional images compared with the axial image to detect the presence, location and orientation of the septum in the maxillary sinus. To analyze the association of the variables we used the chi square or Fisher exact test. The significance level was a < 0.05. For the diagnosis of the presence or absence of the septum, panoramic radiography (7.1%) and the panoramic reconstruction of CBCT (4.2%) were similar to the axial image, however the cross-sectional images differed significantly (12.1%). Regarding the diagnosis of septa location, panoramic radiograph (35%), the panoramic reconstruction of CBCT (33.3%) and cross-sectional images (29.3%) were statistically different from the axial image. Regarding the diagnosis of orientation of the septum, panoramic radiography (1,4% antero posterior and 64,1% bucopalatal), the panoramic reconstruction of CBCT (27,3% and 72,4% bucopalatal), and in cross-sectional images (0,9% infero superior, 9,1% antero posterior and 90,9% bucopalatal) statistically different axial image. In conclusion, the panoramic radiography, panoramic reconstruction of CBCT and cross-sectional images do not provide the necessary information to locate and septum guidance in the maxillary sinus.
92

Acurácia diagnóstica das imagens tomográficas de feixe cônico, com diferentes voxels, na avaliação da cobertura óssea

Oliveira, Luciana Koser 04 December 2014 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2015-07-17T19:42:18Z No. of bitstreams: 1 OLIVEIRA, Luciana Koser.pdf: 2962253 bytes, checksum: 4fe6292b5bc0b9a60eeb5545680814a7 (MD5) / Made available in DSpace on 2015-07-17T19:42:18Z (GMT). No. of bitstreams: 1 OLIVEIRA, Luciana Koser.pdf: 2962253 bytes, checksum: 4fe6292b5bc0b9a60eeb5545680814a7 (MD5) / CNPQ / Uma correta avaliação da condição óssea é essencial para o diagnóstico, prognóstico e estratégias de tratamento do suporte ósseo periodontal. As informações advindas do exame clínico, associadas ao diagnóstico por imagem, servem de guia para uma avaliação apurada sobre o osso alveolar e a possível presença de defeitos ósseos. A tomografia computadorizada de feixe cônico (TCFC) ainda é subutilizada em diagnóstico periodontal, além de pouco pesquisada. Objetivo: Assim, o presente estudo foi desenvolvido com o intuito de estabelecer a acurácia diagnóstica da TCFC na avaliação da cobertura óssea, utilizando diferentes voxels. Material e Métodos: Nos maxilares de cinco crânios secos, com dentição completa, foram identificados 63 defeitos ósseos nos 180 terços dentários de doze dentes anteriores, analisados com o auxílio de um paquímetro digital. Para a aquisição das imagens foi utilizado o aparelho CS 9000 3D Extraoral Dental Cone Beam Imaging System (Carestream Dental, Rochester, USA), com 60 kVp, 8 mA(maxila)/ 6,3 mA(mandíbula) e, primeiramente, a utilização do voxel de 0,2mm, seguido, num segundo momento, da utilização do voxel de 0,076mm. Posteriormente, as imagens adquiridas e reconstruídas nos planos axial e parassagital foram avaliadas por 2 examinadores experientes, de acordo com um protocolo específico, referindo presença ou ausência de cobertura óssea (CO). Todos os dados foram tabulados e analisados pelos testes McNemar e Kappa, adotando o valor de p ≤ 0,05. Resultados: Na avaliação das reconstruções axiais e parassagitais juntas, com voxel 0,2, 95,24% dos sítios com ausência de CO, foram diagnosticados através de imagens por TCFC pelos dois avaliadores, cuja concordância se mostrou substancial (parassagitais, K=0,652; axiais, K=0,756). Na avaliação das reconstruções com voxel 0,076, 93,89% dos sítios com ausência de CO foram diagnosticados e a concordância dos avaliadores se mostrou quase perfeita (parassagitais, K=0,875; axiais, K=0,889). Conclusão: A TCFC apresenta elevada sensibilidade, especificidade e acurácia no diagnóstico da CO, quer em reconstruções parassagitais, quer em reconstruções axiais. As reconstruções parassagitais apresentaram melhor especificidade e acurácia no diagnóstico da CO nos dentes anteriores, quando comparadas com as reconstruções axiais, que por sua vez apresentaram uma sensibilidade superior à das imagens parassagitais, em ambos os voxels analisados. Portanto, é necessária e vantajosa a avaliação dinâmica multiplanar das imagens para confirmar o diagnóstico da cobertura óssea com consequente auxílio nas estratégias de tratamento. Ao comparar os dois voxels avaliados (0,2 e 0,076), os resultados se equivaleram, o que significa que nem sempre haverá ganho de diagnóstico, reduzindo-se, progressivamente, o tamanho do voxel. / A correct assessment of bone condition is crucial for the diagnosis, prognosis and treatment strategies of periodontal bone support. The information resulting from clinical examination, associated with image diagnostic, serve as a guide for an accurate assessment of the alveolar bone and the possible presence of bone defects. The cone beam computed tomography (CBCT) is still underutilized in periodontal diagnosis, besides little researched. Purpose: The aim of the present study was to establish the diagnostic accuracy of the CBCT in the evaluation of bone cover, using different voxels. Material and Methods: In the jaws of five dried skulls, with complete dentition, were identified 63 bone defects in 180 thirds of twelve anterior teeth, analyzed with a digital caliper rule. For the acquisition of the images was used the CS 9000 3D Extraoral Dental Cone Beam Imaging System (Carestream Dental, Rochester, USA), with 60 kVp, 8 mA(maxillae)/ 6.3 mA(jaw) and primarily, the use of voxel of 0.2mm, followed by a second time, with the use of voxel of 0.076mm. Later, the images acquired and reconstructed in axial and parasagittal planes were evaluated by 2 experienced examiners, according to a specific protocol, indicating presence or absence of bone cover. All data were tabulated and analyzed by McNemar and Kappa tests, adopting the value of p≤0,05. Results: In the evaluation of axial and parassagital reconstructions together, with voxel 0.2, 95.24% of the sites with absence of bone cover were diagnosed through images by CBTC, by two assessors, whose agreement was substantial (parassagital reconstructions, K=0.652; axial, K=0.756). In the evaluation of the 0,076 voxel reconstructions, 93,89% of sites with absence of bone cover were diagnosed and the assessors’s agreement was almost perfect (parassagital reconstructions, K=0,875; axial, K=0,889). Conclusion: CBTC offers high sensitivity, specificity and accuracy in diagnosis of bone cover and either in parassagital reconstructions, or in axial reconstructions. The parassagital reconstruction images showed better specificity and accuracy in bone cover diagnosis of anterior teeth than the axial reconstruction ones, which in turn had a higher sensitivity than the parassagital reconstruction images, in both voxels analyzed. Therefore, it is necessary and advantageous a dynamic multiplanar image evaluation to confirm bone cover diagnosis, in order to help treatment strategies. Comparing the voxels evaluated (0.2, 0.076), the results were equivalent, which means that not always there will be gain of diagnosis, reducing progressively the size of the voxel.
93

Avaliação das variações anatômicas do canal mandibular em tomografia computadorizada

Pinto, Regina Lucia Seixas January 2018 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2018-09-05T13:12:32Z No. of bitstreams: 1 TESE Fiinal REGINA.pdf: 1968324 bytes, checksum: 42efa0f0ccbcfdcae94a952140abbdda (MD5) / Approved for entry into archive by Edvaldo Souza (edvaldosouza@ufba.br) on 2018-09-12T21:08:32Z (GMT) No. of bitstreams: 1 TESE Fiinal REGINA.pdf: 1968324 bytes, checksum: 42efa0f0ccbcfdcae94a952140abbdda (MD5) / Made available in DSpace on 2018-09-12T21:08:32Z (GMT). No. of bitstreams: 1 TESE Fiinal REGINA.pdf: 1968324 bytes, checksum: 42efa0f0ccbcfdcae94a952140abbdda (MD5) / O uso das técnicas para obtenção de imagens tridimensionais, como os exames de tomografia computadorizada (TC), tem contribuído significativamente para a visualização das condições de normalidade e alterações das estruturas do complexo dentomaxilofacial, minimizando riscos potenciais diante de procedimentos cirúrgicos que possam envolver a integridade dessas estruturas. Este estudo teve como objetivo avaliar a presença de variações anatômicas do canal mandibular, as quais foram relacionadas ao sexo e lado afetado do indivíduo. A amostra foi constituída por 302 exames de TC multidetectores de mandíbula, de alta resolução, com janela óssea. Foram obtidas reconstruções panorâmicas e transversais da mandíbula, a partir dos cortes axiais obtidos, que foram avaliados duas vezes por um único observador. Os resultados mostraram que 85 (28,1%) TC eram de homens e 217 (71,9%) de mulheres. Do total de exames, 209 (69,2%) apresentaram trajeto único, sendo 44 (14,9%) CMd únicos, bilaterais e altos; 66 (21,9%) CMd únicos, bilaterais e intermediários, e 98 (32,5%) CMd únicos, bilaterais e baixos. As demais TC (93 exames – 30,8%) apresentaram outras variações, sendo 66 (21,9%) com ramificações do CMd, com o tipo 1 de duplicação o padrão mais frequente, e 27 (8,9%) com ausência de simetria. A presença de forames mentual e mandibular acessórios e loop anterior foi pequena; em contrapartida, houve uma grande prevalência de canais na região anterior da mandíbula. Já o canal incisivo mostrou-se presente em 238 (78,8%) TC, mais frequente no sexo feminino. Não foram encontradas associações significantes entre as variações encontradas e o sexo do indivíduo (p> 0,05). / The use of techniques to obtain three-dimensional images, such as computed tomography (CT) scans, has significantly contributed to the visualization of normal conditions and alterations of structures from the dentomaxillofacial complex, minimizing potential risks from surgical procedures that may involve integrity structures. This study aimed to evaluate the presence of anatomical variations of the mandibular canal, which were related to the sex and affected side. The sample consisted of 302 high resolution multidetector mandible CT scans with a bone window. Panoramic and transverse reconstructions of the mandible were obtained from the axial sections, which were evaluated twice by a single observer. The results showed that, 85 (28.1%) CT were men and 217 (71.9%) were women; of the total number of exams, 209 (69.2%) had a single course, of which 45 (14.9%) were bilateral single high MC; 66 (21.9%) bilateral single intermediate MC and 98 (32.5%) bilateral single low MC. The others CT (93 – 30.8%) CT had other variations, 66 (21.9%) were branches of MC and type 1 was the most frequent duplication pattern, and 27 (8.9%) lack of symmetry. As for the presence of accessory mental and mandibular foramina, and anterior loop was small; in contrast there was a high prevalence of canals in the anterior region of the mandible. The mandibular incisive canal was present in 238 (78.8%) CT, more frequent in females. No significant associations were observed between the variations found and the gender of the individual (p> 0.05).
94

Estudo comparativo dos efeitos dentários e periodontais imediatos entre expansão maxilar rápida e lenta por meio de tomografia computadorizada de cone-beam

Brunetto, Mauricio January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-03-04T20:47:08Z (GMT). No. of bitstreams: 1 301034.pdf: 31868781 bytes, checksum: 35c65b6f5843f64944d8700d5510f69d (MD5) / O objetivo deste trabalho foi analisar e comparar, através de imagens de tomografia computadorizada de cone-beam (TCCB), os efeitos imediatos da terapia de expansão maxilar rápida (EMR) e expansão maxilar lenta (EML ) sobre o posicionamento dos primeiros molares superiores, bem como a repercussão sobre a tábua óssea alveolar vestibular destes dentes. A amostra foi composta por 33 pacientes, 18 do sexo feminino e 15 do masculino, média etária de 9 anos, distribuídos aleatoriamente em dois grupos: EMR (n=17) e EML (n=16). Os procedimentos de EMR e EML consistiram, respectivamente, em 2 ativações (0,4mm) diárias e 2 ativações (0,4mm) semanais até que o parafuso expansor atingisse 8mm de expansão. Imagens de tomografia computadorizada de cone-beam (TCCB) foram realizadas ao início (T1) e após a estabilização do parafuso expansor (T2). Os dados foram obtidos através de método padronizado de análise das imagens. O teste Wilcoxon Matched Pairs foi empregado para análise intragrupos, enquanto análise de variância (ANOVA) e correlação de Spearman nas comparações intergrupos. Os dois procedimentos causaram movimentação significativa para vestibular dos dentes 16 e 26. O grupo EML apresentou maior movimento de corpo e o grupo EMR maior inclinação dentária. Perdas ósseas significativas tanto em altura quanto espessura foram detectadas nos dois grupos. O grupo EML apresentou alterações periodontais maiores e mais significativas. Modificações na frequência de ativação do aparelho disjuntor podem influenciar os efeitos dentários e periodontais do tratamento. / The purpose of this study was to analyze and compare the immediate effects of rapid maxillary expansion (RME) and slow maxillary expansion (SME) protocols on the positioning of the upper first molars as well as on the buccal alveolar bone of these teeth by means of conebeam computerized tomography (CBCT). The sample consisted of 33 children, 18 female, and 15 male, with mean age of 9 years, randomly distributed into two groups: RME (n = 17) and SME (n = 16). Patients in the RME group received two turns (0.4 mm) per day and those in the SME group received two turns (0.4 mm) per week until 8 mm of expansion was achieved in both groups. CBCT images were taken before treatment (T1) and after the stabilization of jackscrews (T2). Data were gathered through a standardized analysis of CBCT images. Intragroup statistical analysis was accomplished by a Wilcoxon matched-pairs test, and intergroup statistical analysis was accomplished through analysis of variance (ANOVA). Linear relationships among all variables were determined by Spearman correlation. Both protocols caused buccal displacement of the upper first permanent molars. The upper first molars demonstrated more body displacement in the SME group, while more inclination was observed in the RME group. Vertical and horizontal bone loss was detected in both groups; however, the SME group presented major bone loss. Modifications in the frequency of activation of the palatal expander might influence the dental and periodontal effects of palatal expansion.
95

Melhoria do desempenho metrológico da tomografia computadorizada por raixos X por meio da seleção sistemática dos parâmetros de configuração

Nardelli, Vitor Camargo January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2013-06-25T23:21:45Z (GMT). No. of bitstreams: 1 310201.pdf: 24900586 bytes, checksum: 0d8653a287d04bb1e9c86e79e56d699a (MD5) / A aplicação industrial da tomografia computadorizada (CT) vem crescendo rapidamente na caracterização da geometria de peças. Durante o processo de medição, o usuário deve tomar decisões com relação a parâmetros que influenciam diretamente a qualidade da imagem e, consequentemente, o resultado da medição. Porém, as complexidades inerentes ao processo de medição por CT fazem com que boa parte dos usuários tenham dificuldades para relacionar os valores dos parâmetros de configuração com a qualidade dos dados gerados pela medição. Isso leva normalmente a um processo iterativo de escolha, que afeta negativamente o tempo de setup. Diante deste contexto, o propósito de pesquisa foi demonstrar que é possível sistematizar o processo de seleção dos parâmetros de configuração de forma a obter resultados adequados em termos da incerteza e o tempo de medição, sem necessidade de iteração. Desta forma, usuários com menos conhecimento, tempo e experiência também poderão ser capazes de obter resultados robustos para medições com CT. Como a definição de um critério de qualidade é um aspecto fundamental para a comparabilidade dos resultados, uma importante contribuição deste trabalho é a avaliação da qualidade dos dados gerados por CT através da análise da dispersão dos pontos extraídos de uma determinada característica de referência de uma peça ou padrão. A utilização deste indicador de dispersão em uma abordagem experimental sistêmica resultou na estruturação de um conjunto de regras e recomendações para apoiar o processo de seleção dos parâmetros de configuração. O método para seleção sistemática dos parâmetros de configuração apresentado neste trabalho irá contribuir na orientação de usuários de CT, auxiliar fabricantes na otimização de hardwares e softwares de seus sistemas e auxiliar os metrologistas na identificação e redução das causas de erro das medições. / The application of industrial computed tomography (CT) for the geometrical characterization of work pieces within the scope of quality assurance processes is growing rapidly. When planning the execution of a specific measurement task, the user has to make decisions about the values of parameters that directly influence the image quality and therefore the measurement result. Due to the large number of parameters, the planning and setup processes can be very time consuming. The complex relationships between this parameters and the measurement result makes the planning process strongly dependent on the experience of the user, leading frequently to a trial-and-error setup approach. Based on this context, the purpose of this research is to demonstrate that the process for defining the setup parameters can be sistemized in order to obtain better results in terms of measurement uncertainty and measurement time, without the need of a iterative approach. Therefore, users with less knowledge, time and experience would also be able to get robust measurements from CT systems. Since the definition of a quality index is an essencial requirement for the comparability of the results, an important contribution of this thesis is to assess the quality of the CT extracted data by the analysis of extracted integral features. A systematic experimental approach combined the proposed quality index resulted in the structuring a set of rules and recommendations to assist users on the selection of the setup parameters. The information provided by the systematic approach for selection of setup parameters is complementary to a framework project aiming in developing support systems to help CT users in selecting adequate setup parameters; assisting manufactures on the optimization of their CT systems; and assisting researchers on quantifying sources of measurement errors.
96

Desenvolvimento e validação de novas peças-padrão para tomografia computadorizada industrial

Santos, Rafael Pacheco dos January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2012 / Made available in DSpace on 2013-12-05T22:16:11Z (GMT). No. of bitstreams: 1 317589.pdf: 37414152 bytes, checksum: 0973f5f946c7598685f365423aa96da2 (MD5) Previous issue date: 2012 / A tomografia computadorizada por raios X (TC) é uma emergente tecnologia de medição por coordenadas. Devido ao seu princípio físico que utiliza a atenuação de raios X, a TC permite um controle simultâneo das características geométricas e do material, sendo adequada para a medição de peças de alta complexidade geométrica, de baixa rigidez e de baixa densidade. Durante o processo de preparação de medição (setup) as decisões tomadas pelo usuário têm grande influência sobre a qualidade final da medição. Trata-se de uma etapa demorada e fortemente dependente da experiência do usuário, o que leva geralmente a soluções iterativas baseadas em prova e erro. A geração e sistematização do conhecimento sobre as relações entre a tarefa de medição, parâmetros de configuração e a matriz de voxel resultante pode ser considerado um importante passo para a consolidação da TC no âmbito da metrologia dimensional. Uma iniciativa nesse sentido é desenvolvida no escopo do programa BRAGECRIM. O projeto CT Metro prevê a melhoria do processo de setup através do desenvolvimento de um sistema que objetiva orientar o operador na escolha dos parâmetros de medição. Dentro desse escopo, o presente trabalho teve como objetivo o desenvolvimento e validação experimental de um conjunto de peças que emulem aspectos específicos das tarefas de medição desempenhadas por tomógrafos industriais e que representem a sua grande diversidade. Tais peças foram desenvolvidas com uma abordagem sistemática levando em consideração aspectos específicos da tecnologia. Por fim, um conjunto de medições permitiu a validação das peças e um ganho significativo no entendimento sobre a relação entre parâmetros de configuração e qualidade do processo de medição.<br> / Abstract : The industrial computed tomography (CT) is an emerging technology of coordinate measuring. Due to its physical principle that uses the attenuation of X-ray, CT allows concurrent control of the geometric and materialcharacteristics. It is suitable for measuring the geometric pieces of high complexity, low stiffness and low density. During the preparation process the definition of setup parameters are very important over measurement quality, however is slow and strongly dependent on the user experience which usually leads to iterative solutions. The generation and systematization of knowledge about the relationship among the measurement task, setup parameters and the resulting voxel matrix can be considered an important step towards the consolidation of CT in the context of dimensional metrology. One initiativein this way is developed within the scope of the project CTmetro. This project has the object to design software which will help the user on definition of setup parameters.Within this framework the present work had as objective the development and experimental validation of a set of pieces that emulate specific aspects of measurement tasks performed by industrial CT scanners and representing its great diversity. These pieces were developed with a systematic approach that used the best practices of precision engineering taking into account the specific aspects of technology. Taking care about the manufacturing process that enabled the calibration with low uncertainty values. Finally, the set of measurements allow the validation of parts as well as a significant gain in understanding the relationship between setup parameters and quality of the measurement process.
97

Desenvolvimento de metodologias para a detecção automatizada de pontos de referência anatômicos (landmarks) em volumes tomográficos cerebrais humanos

Silva, Alex Sandro da 20 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência da Computação, Florianópolis, 2002 / Made available in DSpace on 2012-10-20T00:48:45Z (GMT). No. of bitstreams: 1 269457.pdf: 1842356 bytes, checksum: a7560245bb85db0a4bfe7ecfb602fcfd (MD5) / Este trabalho apresenta o desenvolvimento de uma ferrramenta para adaptar automaticamente um atlas cerebral digital, sendo utilizadas imagens de tomografia computadorizada. Será utilizado, para servir como base de um sistema de coordenadas ajustado para cada paciente, um plano conhecido como Plano Horizontal Alemão. O Plano Horizontal Alemão é calculado a partir da base do quarto ventrículo, uma estrutura intracerebral de fácil visualização, e os centros de ambos os olhos. Este plano foi escolhido por atender aos requisitos de relacionamento com a biometria do paciente (posicionamento do quarto ventrículo e olhos) e possibilidade de cálculo com base nas imagens tomográficas. O objetivo é adaptar automaticamente um Atlas Cerebral Digital a qualquer paciente onde foi necessário elaborar uma metodologia de identificação e reconhecimento dessas estruturas intracerebrais (olhos e base do quarto ventrículo). / This work presents the development of tool to adaptation automatically of a brain atlas digital, being used images of computed tomography. A coordinates system adjusted for each patient will be used to serve as base, a known plan as German Horizontal Plan. The German Horizontal Plan is calculated from the fourth ventricle base, a brain structure of easy visualization, and the centers of both the eyes. This plan was chosen by support of the requirements of relationship with the biometric position of the patient (positioning of the fourth ventricle and eyes) and possibility of calculation in tomographic images. The objective is automatically to adapt Brain Atlas Digital to any patient where it was necessary to elaborate a methodology of identification and recognition of these brain structures (eyes and base of the fourth ventricle).
98

Estudo da precisão da análise de tomografias espirais de mandíbulas humanas secas realizadas pelo tomógrafo X-Mind Tome

Munhoz, Felipe Camargo [UNESP] 22 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-22Bitstream added on 2014-06-13T18:53:16Z : No. of bitstreams: 1 munhoz_fc_me_araca.pdf: 428760 bytes, checksum: 52e5bedbe2781e905f522cced7cbd981 (MD5) / O sucesso dos implantes dentários depende de um cuidadoso planejamento préoperatório. O exame radiográfico é de fundamental importância na avaliação da morfologia, inclinação óssea e localização de estruturas anatômicas críticas durante os procedimentos de implantação, quando é necessário medir a quantidade de osso disponível. A Tomografia convencional é um exame de extrema importância, pois permite a mensuração da altura e espessura do rebordo alveolar, determinantes na escolha do tamanho do implante. Poucos autores estudaram a influência da variação do movimento tomográfico na qualidade da imagem. O objetivo deste trabalho foi elucidar precisamente as áreas avaliadas pelas imagens fornecidas por tomografias realizadas pelo tomógrafo espiral X-MIND TOME, fabricado em 2005 pela SOREDEX, Helsink, Finlândia. Foram utilizadas dez mandíbulas humanas secas, desdentadas na região dos pré-molares e molares. Os implantes foram posicionados bilateralmente em oito mandíbulas e unilateralmente em duas, com a distância de 4 mm um do outro. Em seguida, cada mandíbula foi adaptada ao tomógrafo, onde foi realizada uma radiografia panorâmica prévia, com magnificação de 50%. Sobre esta radiografia foi colocado um template que determina a região a ser avaliada, sendo realizados cortes de 4mm de largura, nos dois lados da mandíbula. Comparou-se então a solicitação ao tomógrafo com os resultados obtidos, quanto à distância e a ordem dos cortes solicitados. Foram realizadas 19 tomografias que foram avaliadas utilizando-se o programa Radioimp RADIO MEMORY – Belo Horizonte – Brasil. Em seguida, os dados foram tabulados, analisados e estudados estatisticamente, com nível de significância 5%. Através do teste de Wilcoxon, não foram evidenciadas diferenças estatisticamente significantes nos dados obtidos pelas tomografias, sendo, portanto, precisas. / The success of dental implants depends on a carefull pre-opertative planning. The radiographic exam is of main importance for a correct evaluation of morphology, bone inclination and location of critical anatomical structures during the surgical procedures for dental implants, when it’s necessary to measure the amount of available bone. The conventional Tomography is a very important exam, because it allows the measurement of height and thickness of the alveolar bone for the determination of the implant’s size. Few authors studied the influence of the tomographic movement variation in the quality of the image. The aim of the present paper is to clarify the precision of the areas evaluated by the images given by the spiral scanning X-MIND TOME, made in 2005 by SOREDEX, Helsink, Finland. There were used 10 dried mandibles, toothless in the region of pre-molars and molars. The implants were placed in both sides in eight mandibles and in one side in two, with the distance of 4mm one from another. After this, each mandible was placed in the scanning, where a previous panoramic radiograph was taken, with magnification of 50%. Upon this radiograph, it was placed a template to determine the region to be evaluated, where there were made cuts of 4mm of width, in both sides of the mandible. The scanning request was then compared to the obtained results. It was made 19 radiographs that were evaluated using the Radioimp program (RADIO MEMORY – Belo Horizonte – Brazil). The data were then analyzed and studied statistically, with significance of 5%. Throught wilcoxon test, there were not noticed statistical differences in the data obtained in the tomographies, that showed to be precise.
99

Identificação do sexo de psitacídeos (Amazona aestiva) por meio da avaliação gonadal, utilizando a tomografia computadorizada (TC)

Lehmkuhl, Ricardo Coelho [UNESP] 30 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-30Bitstream added on 2014-06-13T20:47:24Z : No. of bitstreams: 1 lehmkuhl_rc_dr_botfmvz.pdf: 1482245 bytes, checksum: 30e1c612a38d10c841536db8a5de2264 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar a técnica de tomografia computadorizada como meio da visibilização e identificação dos órgãos reprodutivos (gônadas). Utilizou-se 38 aves da espécie Amazona aestiva, com sexo indeterminado e idade superior a cinco anos, para realizar o exame tomográfico utilizou-se anestesia dissociativa a base de quetamina e xilazina. As aves foram posicionadas em decúbito dorsal, e realizou-se os cortes axiais com intervalo de um milímetro. As imagens tomográficas adquiridas foram submetidas à reconstrução multiplanar (MPR) com cortes dorsais e sagitais, possibilitando a caracterização das gônadas tanto masculina, quanto feminina, com 100% de eficiência, confirmadas por meio de análise comparativa com técnica de polimorfismo de DNA, demonstrando a eficácia da tomografia computadorizada na avaliação e sexagem de psitacídeos da espécie Amazona aestiva / The aim of this study was to evaluate the technique of computed tomography (CT) to visualize and identify the reproductive organs (gonads). Thirty-eight Amazona aestiva parrots of unknown sex, older than 5 years of age were used. For anesthesia, ketamine and xylazine were administered. The birds were placed in dorsal recumbency for CT and images were acquired with axial slices at 1-mm collimation. Multiplanar reconstruction (MPR) was performed using dorsal and sagittal slices in order to identify male and female gonads, reaching 100% efficiency as confirmed by the DNA polymorphism technique, so demonstrating the efficacy of the tomography for sexing Psittacidae parrots of the species Amazona aestiva
100

Avaliaçao da taxa de compressao sem perdas em projeçoes de tomografia computadorizada

Martins, Valdir, Ribeiro, Eduardo Parente 27 October 2010 (has links)
No description available.

Page generated in 0.024 seconds