• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 28
  • 7
  • 7
  • 4
  • 4
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 97
  • 25
  • 24
  • 23
  • 21
  • 20
  • 14
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desenvolvimento de sensores baseados em reflectometria no domínio do tempo para análise de combustíveis. / Time domain reflectometry-based sensors development for fuel analysis.

Rodrigues, Daniel Brás Rochinha 05 September 2016 (has links)
Este trabalho apresenta um estudo da técnica da Reflectometria no Domínio do Tempo - TDR, para qualificação de álcool combustível. Há grande interesse na qualificação de combustíveis pois a adulteração é uma prática comum no Brasil e tem implicações nocivas no funcionamento do motor, causa maior poluição ambiental e evasão fiscal. O presente estudo foi focado em etanol adulterado com água, utilizando uma sonda comercial e sondas desenvolvidas neste trabalho, tendo sido dividido em três etapas: a primeira etapa consistiu em confirmar a viabilidade da técnica TDR para o tema proposto utilizando o sensor comercial de umidade de solo VG400 da Vegetronix, enquanto que o segundo passo tratou da simulação de sondas dos tipos bifilar, microstrip, coaxial e helicoidal em simulador tridimensional de eletromagnetismo, visando a escolha e otimização do tipo de sonda a ser usada para a qualificação do combustível. O terceiro e último passo consistiu na fabricação das sondas simuladas escolhidas e na realização de ensaios utilizando amostras de etanol com variadas proporções de água. Este estudo mostrou que a sonda helicoidal, que é uma proposta original deste trabalho, apresentou maior sensibilidade entre os modelos escolhidos, mostrando uma variação de resposta entre as amostras de etanol e água puros 12,5% maior que a sonda bifilar, que é a segunda sonda mais sensível dentre as estudadas. / This work presents a study of the Time-Domain Reflectometry - TDR technique for ethanol fuel qualification. There is a great interest in fuel qualification since adulteration is a common practice, which brings harmful consequences to the vehicle motor functioning, besides causing higher environmental pollution and tax evasion. The present study is focused on the qualification of ethanol adulterated with water, by using a commercial probe and probes developed in this work. It was divided in three steps: the first step has confirmed the viability of the technique for the proposed theme using a commercial sensor Vegetronix VG400 for soil moisture analysis. The second step was the simulation of bifilar, microstrip, coaxial and helical probe geometries using a 3D eletromagnectics software, leading to the optimization of the probe for fuel qualification. The last step was the fabrication of the simulated probes and the test of their performance into alcohol adulterated with various proportions of water. This study showed that the helical probe, an original proposal of this work, presented higher sensibility among the chosen models. Its response variation between pure alcohol and pure water was 12.5% greater than the bifilar probe, which was the second most sensitive sensor among the studied geometries.
32

Desenvolvimento de sensores baseados em reflectometria no domínio do tempo para análise de combustíveis. / Time domain reflectometry-based sensors development for fuel analysis.

Daniel Brás Rochinha Rodrigues 05 September 2016 (has links)
Este trabalho apresenta um estudo da técnica da Reflectometria no Domínio do Tempo - TDR, para qualificação de álcool combustível. Há grande interesse na qualificação de combustíveis pois a adulteração é uma prática comum no Brasil e tem implicações nocivas no funcionamento do motor, causa maior poluição ambiental e evasão fiscal. O presente estudo foi focado em etanol adulterado com água, utilizando uma sonda comercial e sondas desenvolvidas neste trabalho, tendo sido dividido em três etapas: a primeira etapa consistiu em confirmar a viabilidade da técnica TDR para o tema proposto utilizando o sensor comercial de umidade de solo VG400 da Vegetronix, enquanto que o segundo passo tratou da simulação de sondas dos tipos bifilar, microstrip, coaxial e helicoidal em simulador tridimensional de eletromagnetismo, visando a escolha e otimização do tipo de sonda a ser usada para a qualificação do combustível. O terceiro e último passo consistiu na fabricação das sondas simuladas escolhidas e na realização de ensaios utilizando amostras de etanol com variadas proporções de água. Este estudo mostrou que a sonda helicoidal, que é uma proposta original deste trabalho, apresentou maior sensibilidade entre os modelos escolhidos, mostrando uma variação de resposta entre as amostras de etanol e água puros 12,5% maior que a sonda bifilar, que é a segunda sonda mais sensível dentre as estudadas. / This work presents a study of the Time-Domain Reflectometry - TDR technique for ethanol fuel qualification. There is a great interest in fuel qualification since adulteration is a common practice, which brings harmful consequences to the vehicle motor functioning, besides causing higher environmental pollution and tax evasion. The present study is focused on the qualification of ethanol adulterated with water, by using a commercial probe and probes developed in this work. It was divided in three steps: the first step has confirmed the viability of the technique for the proposed theme using a commercial sensor Vegetronix VG400 for soil moisture analysis. The second step was the simulation of bifilar, microstrip, coaxial and helical probe geometries using a 3D eletromagnectics software, leading to the optimization of the probe for fuel qualification. The last step was the fabrication of the simulated probes and the test of their performance into alcohol adulterated with various proportions of water. This study showed that the helical probe, an original proposal of this work, presented higher sensibility among the chosen models. Its response variation between pure alcohol and pure water was 12.5% greater than the bifilar probe, which was the second most sensitive sensor among the studied geometries.
33

Estudo do colapso do solo através de ensaios de placa monitorados com tensiômetros e tomografia computadorizada / Study of soil collapse through plate tests monitored with tensiometers and computerized tomography

Conciani, Wilson 28 April 1997 (has links)
Esta tese apresenta um estudo de solos colapsíveis utilizando provas de carga em placas executados com inundação da cava. Durante o ensaio a sucção foi monitorada com tensiômetros instalados em cinco profundidades distintas. A inundação da cava foi também monitorada pelo uso da técnica de reflectometria no domínio do tempo. Desta forma pode-se acompanhar a evolução da frente de infiltração e da sucção durante todas as fases do ensaio. Foi introduzido também o uso da tomografia computadorizada para registrar as alterações causadas no solo pelo carregamento e posterior inundação. O acompanhamento da frente de infiltração durante o ensaio foi importante para conhecer a profundidade de influência do colapso no maciço do solo. De posse dos valores de sucção, foi possível a utilização de modelos para solo não saturado para verificar a sua aplicabilidade na previsão de comportamento de estruturas de fundação. A tomografia computadorizada forneceu informações a respeito da distribuição de massa específica do solo antes e depois do carregamento, permitindo concluir que a região mais afetada pelo colapso se restringe a 0,25 D. / This thesis presents a soil collapse study using plate load tests performed with soaking the test pit. During the test suction was monitored by tensiometers embedded at five different depths. Thus, it was possible to follow the wetting front and suction evolution all over the tests stages. lt was also introduced the computerized tomography technique to record the soil changing caused by loading and wetting. Monitoring the wetting front during the test was important to know the influence depth of collapse at soil mass. Having the suction values it was possible to use behaviour models of unsaturated soils to verity their applicability on predicting foundations structure settlements. The computerized tomography yields informations about soil unit weight distribution before and after loading, allowing concludes that collapse most affected region is restrained up to 0.25 D.
34

Utilização da técnica da reflectometria no domínio do tempo para medidas de condutividade elétrica aparente de um solo / Use of the time domain reflectometry technique for soil bulk electrical conductivity measurements

Oro, Alice Leal Terres 20 July 2006 (has links)
Made available in DSpace on 2017-07-10T19:25:03Z (GMT). No. of bitstreams: 1 Alice Leal Terres Oro.pdf: 734105 bytes, checksum: 00f0a2e6f0c0139384a1298b29fdcc57 (MD5) Previous issue date: 2006-07-20 / Measurements of solute concentrations at soils are essential to optimize irrigation and fertilizer application, to study surface runoff and erosion and to evaluate soil salinity. For this purpose, Time Domain Reflectometry is a dielectric technique that has been shown to give accurate water content and electrical conductivity values. Used under both laboratory and field conditions, this a non-destructive essay takes simultaneous measurements of electrical conductivity and soil water content, using a single probe and testing only one sample region. Although there are many ways in which electrical conductivity may be obtained with Time Domain Reflectometry equipment, few of them are characterized by simplicity and straight forwardness. Because of that, this study aimed to evaluate different methods to determine electrical conductivity at solutions and soils. A sequence of laboratory experiments was conducted in deformed soil samples of an Oxisol from West Parana State, arranged in columns 0,30 m height, with an internal diameter of 0,19 m. The three wire probes, with manual assembling and without impedance-matching transformer, were vertically installed in soil columns, considering as a control one the column which soil received only distilled water. The others treatments were defined according to the sodium chloride content: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 and 0,15 N. The electrical conductivity was determined using waveforms collected with specific software and there wasn t signal attenuation. It was found a linear relationship between the bulk electrical conductivity and the pore water electrical conductivity under constant water content. It was concluded that soils with significant iron contents display an atypical dielectric behavior that limits the applicability of the equipment for measuring not only soil moisture but bulk electrical conductivity also. / Medidas de concentrações de solutos em solos são essenciais para otimizar a irrigação e aplicações de fertilizantes, para estudar escoamento superficial e erosão e para avaliar a salinidade do solo. Para tal fim, a Reflectometria no Domínio do Tempo é uma técnica dielétrica que tem sido capaz de fornecer valores precisos, tanto para teores de água como para condutividade elétrica do solo. Empregada tanto em condições de laboratório como em condições de campo, esta técnica não-destrutiva realiza medidas simultâneas das duas grandezas, empregando uma única sonda e testando a mesma região da amostra. Embora existam várias técnicas através das quais a condutividade elétrica pode ser determinada com um equipamento de Reflectometria no Domínio do Tempo, poucas técnicas são caracterizadas pela simplicidade e pela rapidez. Devido a isso, o presente trabalho objetivou avaliar diferentes métodos para a determinação da condutividade elétrica de soluções e de solos. O trabalho foi desenvolvido em condições de laboratório, usando amostras deformadas de um Latossolo Vermelho distroférrico da Região Oeste do Paraná, acondicionadas em colunas com comprimento de 0,30 m e diâmetro de 0,19 m. As sondas com 3 hastes, montadas de forma artesanal e sem qualquer equalização de impedâncias, foram instaladas verticalmente nas colunas de solo, sendo considerada como controle a coluna cujo solo recebeu água destilada. Os outros tratamentos foram definidos conforme os teores de cloreto de sódio adicionado: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 e 0,15 N. A condutividade elétrica foi determinada a partir das formas de onda coletadas com um programa específico e não ocorreu atenuação de sinal. Encontrou-se uma relação linear entre as medidas de condutividade elétrica total do solo e a condutividade elétrica da solução do solo, sob umidade constante. Também se concluiu que solos com alto teor de Fe exibem um comportamento dielétrico atípico, o qual limita a aplicabilidade da técnica.
35

Utilização da técnica da reflectometria no domínio do tempo para medidas de condutividade elétrica aparente de um solo / Use of the time domain reflectometry technique for soil bulk electrical conductivity measurements

Oro, Alice Leal Terres 20 July 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:24Z (GMT). No. of bitstreams: 1 Alice Leal Terres Oro.pdf: 734105 bytes, checksum: 00f0a2e6f0c0139384a1298b29fdcc57 (MD5) Previous issue date: 2006-07-20 / Measurements of solute concentrations at soils are essential to optimize irrigation and fertilizer application, to study surface runoff and erosion and to evaluate soil salinity. For this purpose, Time Domain Reflectometry is a dielectric technique that has been shown to give accurate water content and electrical conductivity values. Used under both laboratory and field conditions, this a non-destructive essay takes simultaneous measurements of electrical conductivity and soil water content, using a single probe and testing only one sample region. Although there are many ways in which electrical conductivity may be obtained with Time Domain Reflectometry equipment, few of them are characterized by simplicity and straight forwardness. Because of that, this study aimed to evaluate different methods to determine electrical conductivity at solutions and soils. A sequence of laboratory experiments was conducted in deformed soil samples of an Oxisol from West Parana State, arranged in columns 0,30 m height, with an internal diameter of 0,19 m. The three wire probes, with manual assembling and without impedance-matching transformer, were vertically installed in soil columns, considering as a control one the column which soil received only distilled water. The others treatments were defined according to the sodium chloride content: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 and 0,15 N. The electrical conductivity was determined using waveforms collected with specific software and there wasn t signal attenuation. It was found a linear relationship between the bulk electrical conductivity and the pore water electrical conductivity under constant water content. It was concluded that soils with significant iron contents display an atypical dielectric behavior that limits the applicability of the equipment for measuring not only soil moisture but bulk electrical conductivity also. / Medidas de concentrações de solutos em solos são essenciais para otimizar a irrigação e aplicações de fertilizantes, para estudar escoamento superficial e erosão e para avaliar a salinidade do solo. Para tal fim, a Reflectometria no Domínio do Tempo é uma técnica dielétrica que tem sido capaz de fornecer valores precisos, tanto para teores de água como para condutividade elétrica do solo. Empregada tanto em condições de laboratório como em condições de campo, esta técnica não-destrutiva realiza medidas simultâneas das duas grandezas, empregando uma única sonda e testando a mesma região da amostra. Embora existam várias técnicas através das quais a condutividade elétrica pode ser determinada com um equipamento de Reflectometria no Domínio do Tempo, poucas técnicas são caracterizadas pela simplicidade e pela rapidez. Devido a isso, o presente trabalho objetivou avaliar diferentes métodos para a determinação da condutividade elétrica de soluções e de solos. O trabalho foi desenvolvido em condições de laboratório, usando amostras deformadas de um Latossolo Vermelho distroférrico da Região Oeste do Paraná, acondicionadas em colunas com comprimento de 0,30 m e diâmetro de 0,19 m. As sondas com 3 hastes, montadas de forma artesanal e sem qualquer equalização de impedâncias, foram instaladas verticalmente nas colunas de solo, sendo considerada como controle a coluna cujo solo recebeu água destilada. Os outros tratamentos foram definidos conforme os teores de cloreto de sódio adicionado: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 e 0,15 N. A condutividade elétrica foi determinada a partir das formas de onda coletadas com um programa específico e não ocorreu atenuação de sinal. Encontrou-se uma relação linear entre as medidas de condutividade elétrica total do solo e a condutividade elétrica da solução do solo, sob umidade constante. Também se concluiu que solos com alto teor de Fe exibem um comportamento dielétrico atípico, o qual limita a aplicabilidade da técnica.
36

Perdas de água por evaporação de um solo cultivado com milho nos sistemas de plantio direto e convencional / Loss of water evaporation of cultived soil with maize in notillage system and conventional tillage

Andrade, Juliano Gomes de 04 April 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Worldwide, the agricultural sector is the largest consumer of water, reaching about 69% of total water derived from rivers, lakes and underground aquifers. Because of this huge consumption of water by agriculture and the scarcity of water in various parts of the world there is a social and environmental pressure very big, mainly on irrigated agriculture in order to improve the efficiency of the use of water. This study aimed to quantify the loss of water from the soil by evaporation, in the early stages of development of the corn crop sown in cultivation from no-tillage system and conventional tillage. The work was developed in Experimental Area of the Department of Rural Engineering of the Federal University of Santa Maria (UFSM), RS. The experiment was conducted in the period from October 28, 2006 to December 10, 2006 and consisted of four treatments: (i) direct maize sowing in bare soil (PD0), (ii) direct sowing of corn with 3,0 Mg ha-1 of straw on the soil surface (PD3), (iii) direct sowing of corn with 6,0 Mg ha-1 of straw on the soil surface (PD6), and (iv) conventional tillage of the soil without coverage of straw on the surface (PC). The loss of water from the soil were determined in four cycles of dry soil during the first 38 days after the emergence of culture, holding up the water balance in soil layers from 0 to 10 cm and 10 to 30 cm, from data of volumetric soil moisture determined with a TDR at intervals of 15 minutes. It was also determined, for the first cycle of drying soil coefficients of evaporation(K) and reducing of water evaporation from the soil (Kr), as the methodology of Kc Dual. For the short duration of the cycles of drying of the soil, growth and development of plants were not affected by the system of cultivation of the soil in the early stages of development of the corn crop. In layer from 0 to 10 cm depth for the first cycle of drying of the soil, 3,0 Mg ha-1 of straw on the surface provided a reduction in the loss of water by evaporation of 24,6% and 19,9% in relation to the PC and PD0, respectively. With 6.0 Mg ha-1 of straw, the reduction was 50,7% and 47,6%, respectively. In the first 30 cm of the soil profile, the reduction in losses of water was 18.2% and 23% respectively to 3.0 Mg ha-1 of straw. Increasing to 6.0 Mg ha-1 reduction was 38,3% and 42,0% respectively. With the growth of culture, the increase in the loss of water in the soil was due to the bigger development of plants with increasing participation of transpiration in water consumption by culture, by shading the surface at the higher leaf area index of the plants. Treatments with PC and PD0 show Ke higher, reaching 1,32 and 1,17, respectively. With the presence of straw, the maximum value of K was reduced to approximately 50% compared with the treatments without straw on the surface reaching values of 0,70 and 0,44, respectively, when EToac was 10,0 mm. The treatments of PC and PD0 showed a fast reduction in the coefficient of reduction of water evaporation from soil, after 6,5 mm of EToac. The lowest value of Kr at the end of the cycle of drying, 0,47, was observed for the treatment PD0. The PD6 has remained longer in the first stage of evaporation, reducing the Kr when EToac exceeded 20,0 mm. / Mundialmente, o setor agrícola é o maior consumidor de água, alcançando cerca de 69% do total de água derivada de rios, lagos e aqüíferos subterrâneos. Em função deste grande consumo de água pela agricultura e pela escassez de água em várias partes do mundo, há uma pressão social e ambiental muito grande, principalmente sobre a agricultura irrigada, a fim de melhorar a eficiência do uso da água. Este estudo teve como objetivo quantificar as perdas de água do solo por evaporação, nos estádios iniciais de desenvolvimento da cultura do milho semeada em sistema de cultivo direto e preparo convencional. O trabalho foi desenvolvido em Área Experimental do Departamento de Engenharia Rural da Universidade Federal de Santa Maria (UFSM), RS. O experimento foi conduzido no período de 28 de outubro de 2006 a 10 de dezembro de 2006 e constituiu-se de quatro tratamentos: (i) semeadura direta do milho em solo desnudo (PD0); (ii) semeadura direta do milho com 3,0 Mg ha-1 de palha na superfície do solo (PD3); (iii) semeadura direta do milho com 6,0 Mg ha-1 de palha na superfície do solo (PD6) e, (iv) preparo convencional do solo, sem cobertura de palha na superfície (PC). As perdas de água do solo foram determinadas em quatro ciclos de secagem do solo durante os primeiros 38 dias após a emergência da cultura, realizando-se o balanço hídrico do solo nas camadas de 0 a 10 cm e de 10 a 30 cm, a partir dos dados de umidade volumétrica do solo determinada com um TDR em intervalos de 15 minutos. Determinou-se também, para o primeiro ciclo de secagem do solo os coeficientes de evaporação (Ke) e de redução da evaporação da água do solo (Kr), conforme a metodologia do Kc Dual de cultivo. Pela curta duração dos ciclos de secagem do solo, o crescimento e o desenvolvimento das plantas não foram influenciados pelo sistema de cultivo do solo nas fases iniciais de desenvolvimento da cultura do milho. Na camada de 0 a 10 cm de profundidade, para o primeiro ciclo de secagem do solo, 3,0 Mg ha-1 de palha na superfície proporcionou uma redução nas perdas de água por evaporação de 24,6% e 19,9% em relação ao PC e PD0, respectivamente. Com 6,0 Mg ha-1 de palha, a redução foi de 50,7% e 47,6%,respectivamente. Nos primeiros 30 cm do perfil do solo, a redução nas perdas de água foi de 18,2% e 23%, respectivamente com 3,0 Mg ha-1 de palha. Aumentando para 6,0 Mg ha-1 a redução foi de 38,3% e 42% respectivamente. Com o crescimento da cultura, o aumento nas perdas de água do solo foi devido ao maior desenvolvimento das plantas com aumento da participação da transpiração no consumo de água pela cultura, pelo sombreamento da superfície pelo maior índice de área foliar das plantas. Os tratamentos com PC e PD0 apresentam Ke mais elevado, chegando a 1,32 e 1,17, respectivamente. Com a presença de palha, o máximo valor de Ke foi reduzido para aproximadamente 50% comparados com os tratamentos sem palha na superfície atingindo valores de 0,70 e 0,44, respectivamente, quando EToac era de 10,0 mm. Os tratamentos de PC e PD0 apresentaram uma rápida redução no coeficiente de redução da evaporação da água do solo, após 6,5 mm de EToac. O menor valor de Kr no final do ciclo de secagem, 0,47, foi observado para o tratamento PD0. O PD6 manteve-se por mais tempo no primeiro estagio da evaporação, reduzindo o Kr quando a EToac superou 20,0 mm.
37

Estudo do colapso do solo através de ensaios de placa monitorados com tensiômetros e tomografia computadorizada / Study of soil collapse through plate tests monitored with tensiometers and computerized tomography

Wilson Conciani 28 April 1997 (has links)
Esta tese apresenta um estudo de solos colapsíveis utilizando provas de carga em placas executados com inundação da cava. Durante o ensaio a sucção foi monitorada com tensiômetros instalados em cinco profundidades distintas. A inundação da cava foi também monitorada pelo uso da técnica de reflectometria no domínio do tempo. Desta forma pode-se acompanhar a evolução da frente de infiltração e da sucção durante todas as fases do ensaio. Foi introduzido também o uso da tomografia computadorizada para registrar as alterações causadas no solo pelo carregamento e posterior inundação. O acompanhamento da frente de infiltração durante o ensaio foi importante para conhecer a profundidade de influência do colapso no maciço do solo. De posse dos valores de sucção, foi possível a utilização de modelos para solo não saturado para verificar a sua aplicabilidade na previsão de comportamento de estruturas de fundação. A tomografia computadorizada forneceu informações a respeito da distribuição de massa específica do solo antes e depois do carregamento, permitindo concluir que a região mais afetada pelo colapso se restringe a 0,25 D. / This thesis presents a soil collapse study using plate load tests performed with soaking the test pit. During the test suction was monitored by tensiometers embedded at five different depths. Thus, it was possible to follow the wetting front and suction evolution all over the tests stages. lt was also introduced the computerized tomography technique to record the soil changing caused by loading and wetting. Monitoring the wetting front during the test was important to know the influence depth of collapse at soil mass. Having the suction values it was possible to use behaviour models of unsaturated soils to verity their applicability on predicting foundations structure settlements. The computerized tomography yields informations about soil unit weight distribution before and after loading, allowing concludes that collapse most affected region is restrained up to 0.25 D.
38

Avaliação de modelos matemáticos para dimensionamento do bulbo molhado na irrigação por gotejamento / Evaluation of mathematical models for wet bulb design in drip irrigation

Sato, Lucas Massayuki 30 March 2012 (has links)
Made available in DSpace on 2016-06-02T18:55:23Z (GMT). No. of bitstreams: 1 4272.pdf: 2401909 bytes, checksum: 472e7aaca2322a7de8b1b169aa30fdd5 (MD5) Previous issue date: 2012-03-30 / Financiadora de Estudos e Projetos / The increasing current demand of water has caused conflicts between their multiple uses, being the agriculture responsible for the use of the largest portion of this natural resource. In this context, drip irrigation has shown growth in irrigated area due to their potential to achieve high efficiency in water application. Drip irrigation is characterized by the application of small volumes of water at high frequency directly in the root zone of plants, helping to maintain soil moisture near field capacity in a given volume of soil usually called the wet bulb. Knowing the dimensions of the wetted generated to be used in drip irrigation project is of fundamental importance for the proper design and operation of drip irrigation systems. The objective of this study was to test the performance of the mathematical models Schwartzman and Zur Reprinted and HYDRUS-2D in predicting dimensions of wet bulb generated generated by emitters of different flow flow rates. In its first part, held at the experimental field of Taubate University, were collected the dimensions of the wet bulbs generated by drip of 2, 4 and 8 L h-1 in a dystrophic red-yellow. In the second, were simulated the dimensions of wet bulb using Schwartzman and Zur Reprinted and HYDRUS-2D models. Statistical analysis used to evaluate the performance of these models have shown that the model Schwartzman Zur Reproduced predicted the experimental data set with an accuracy of 94%, whereas in the case of model HYDRUS-2D, this accuracy was 85%. It was concluded that the two studied models can adequately estimate the dimensions of the wet bulb, for the studied conditions, highlighting, however, that the model performed better was Schwartzman-Zur Reprinted. / A crescente demanda de água tem originado conflitos entre seus usos múltiplos, sendo a agricultura responsável pela utilização da maior parcela deste recurso natural. Neste quadro, a irrigação por gotejamento tem apresentado crescimento em área irrigada devido a sua potencialidade de obter alta eficiência na aplicação de água. A irrigação por gotejamento é caracterizada pela aplicação de pequenos volumes de água em alta frequência diretamente na zona radicular das plantas, permitindo manter a umidade do solo próxima a sua capacidade de campo em um determinado volume de solo denominado normalmente de bulbo molhado. O conhecimento das dimensões do bulbo molhado gerado pelo gotejador a ser utilizado no projeto de irrigação é de fundamental importância para o correto dimensionamento e operação dos sistemas de irrigação por gotejamento. O objetivo deste trabalho foi testar o desempenho dos modelos Schwartzman-Zur Reproduzido e HYDRUS-2D na previsão das dimensões dos bulbos molhados gerados por gotejadores de diferentes vazões. Na sua primeira parte, realizada na área experimental da Universidade de Taubaté, foram coletadas as dimensões dos bulbos molhados gerados por gotejadores de 2, 4 e 8 L.h-1 em um Latossolo vermelhoamarelo. Na segunda, foram simuladas as dimensões dos bulbos molhados utilizando-se os modelos matemáticos Schwartzman-Zur Reproduzido e HYDRUS-2D. Os estudos estatísticos utilizados para avaliar o desempenho desses modelos mostraram que o modelo de Schwartzman-Zur Reproduzido ajustou os dados experimentais com precisão de 94%, enquanto que, no caso do modelo HYDRUS-2D, esta precisão foi de 85%. Concluiu-se que os dois modelos estudados podem estimar adequadamente as dimensões do bulbo molhado para as condições estudadas, destacando-se, porém, que o modelo que apresentou melhor desempenho foi o de Schwartzman-Zur Reproduzido.
39

Influência dos resíduos vegetais na superfície do solo na dinâmica de evaporação da água e temperatura do solo / Influence of plant residues on the soil surface in the dynamics of water evaporation and soil temperature

Chabat, Manuel Camilo Moura 21 May 2010 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The availability and proper management of water represent fundamental aspects of the development of sustainable agricultural production systems, since it has direct impact on crop productivity. Maintaining crop residues on the soil surface reduces soil water loss by evaporation and soil temperature changes. Irrigation may be an efficient and safe tool to increase and support crop yields. The accuracy of crop evapotranspiration calculation is important for obtaining satisfactory results, in this context the use of dual crop coefficient allows for the accurate estimation considering separately evaporation soil and crop transpiration. Thus, the objective was to evaluate the influence of plant residues on the surface on the dynamics of water evaporation and soil temperature in the early stages of development of soybean plants. Moreover: (i) quantify plant residues effects on water evaporation, (ii) determine the effect of coverage on soil temperature and (iii) to compare the results obtained under field conditions with simulations performed with the dual crop coefficient methodology. A trial was done on a set of drainage lysimeters installed in a rain-out shelter, located in Las Brujas Experimental Station (34 ° 40 '19''S, 56 ° 20'24''W., altitude 45 m) of the National Research Institute of Agriculture (INIA), Uruguay. Design experimental was completely randomized, factorial with three replications. The factor A was composed of two levels of ground cover (0 and 4 Mg ha-1 of oat straw) and the factor B represented the area of soybean cultivation (with and without plants). Water losses were determined in soil drying cycles based on reference evapotranspiration (ETo). It was estimated by the Penman-Monteith equation.The soil water content was determined with TDR sensors installed at 0-10 cm and 10-30 cm depth. Soil temperature was measured with thermometers installed at 5 and 10 cm depths, records every 30 minutes. The evaporation rate of soil water was reduced 50% by plant residues on the soil surface. The soil cover resulted in maximum temperature 6 º C lower, minimum temperature 2 ° C higher and temperature range 40% lower. The soil water simulations using dual crop coefficient methodology resulted in good agreement with values measured in soil lysimeters without cover and on the ground covered by crop residues. / A disponibilidade e o manejo apropriado da água representam aspectos fundamentais para o desenvolvimento de sistemas de produção agrícola sustentáveis, visto que esta tem impacto direto na produtividade das culturas. A manutenção de resíduos vegetais na superfície do solo diminui as perdas de água do solo por evaporação e altera a temperatura do solo. A irrigação se apresenta como uma ferramenta eficiênte e segura de aumentar e estabilizar os rendimentos das culturas. A exatidão no cálculo da evapotranspiração das culturas é importante para a obtenção de resultados satisfatórios, nesse contexto o uso de coeficientes culturais duais permite realizar estimativas precisas considerando separadamente a evaporação do solo e a transpiração da cultura. Dessa forma, o objetivo deste trabalho foi avaliar a influência dos resíduos vegetais na superfície sobre a dinâmica de evaporação de água e temperatura do solo nas fases iniciais de desenvolvimento de plantas de soja. Alem disso: (i) quantificar o efeito dos resíduos vegetais na evaporação de água; (ii) determinar o efeito da cobertura na temperatura do solo e; (iii) comparar os resultados obtidos em nivel de campo com simulações realizadas com a metodologia de coeficientes culturais duais. Foi realizado um experimento num conjunto de lisimetros de drenagem instalados em uma casa de vegetação móvel (rainout shelter), localizado na Estação Experimental Las Brujas (34°40´ 19´´ S., 56°20´24´´ W., altitude 45 m) do Instituto Nacional de Investigación Agropecuaria (INIA), Uruguai. O delineamento experimental utilizado foi o inteiramente casualizado, bifatorial com três repetições. O fator A foi constituido de dois níveis de cobertura do solo (0 e 4 Mg ha-1 de palha de aveia) e o fator B representou o cultivo da área com soja (com e sem cultivo). As perdas de água foram determinadas em ciclos de secagem do solo baseados na evapotranspiração de referência (ETo), estimada pela equação Penman Monteith-FAO. O conteúdo volumétrico de água foi determinado com sensores TDR instalados nas camadas de 0-10 cm e de 10-30 cm de profundidade. A temperatura do solo foi medida com termômetros instalados nas profundidades de 5 e 10 cm, com leituras a cada 30 minutos. A taxa de evaporação de água do solo foi diminuída em 50% pelos resíduos vegetais na superfície do solo. A cobertura do solo resultou em temperatura máxima 6 ºC menor, temperatura mínima 2 ºC maior e amplitude térmica 40% menor. As estimativas de água disponível no solo efetuadas com a metodologia dos Kc duais apresentaram boa concordância com valores medidos nos lisímetros tanto no solo sem cobertura como no solo coberto por residuos vegetais.
40

[en] RAIN VS. MOISTURE RELATIONSHIP IN UNSATURATED SOILS / [pt] RELAÇÃO CHUVA VS. UMIDADE EM SOLOS NÃO SATURADOS

MARCELA STRONGYLIS 21 June 2021 (has links)
[pt] O propósito do trabalho é avaliar a viabilidade técnica do uso de sondas tipo TDR e tensiômetros no monitoramento de encostas não saturadas. Com tais instrumentos, objetiva-se monitorar a variação da sucção mátrica e da umidade no solo em períodos chuvosos, visando aperfeiçoar os sistemas de alerta usados em áreas de risco e, consequentemente, minimizar perdas materiais e humanas. Para as medições, foram instalados uma estação meteorológica (munida de um pluviômetro, um datalogger, uma placa solar e uma antena para a transmissão de dados via internet), quatro sensores de umidade tipo TDR e um tensiômetro de alta capacidade em uma encosta localizada a montante da Faculdade de Medicina de Petrópolis, cidade da região serrana do estado do Rio de Janeiro. Foram registrados cerca de três meses de dados das sondas tipo TDR e, por conta de uma pane elétrica, apenas treze dias de dados do tensiômetro. As sondas tipo TDR apresentaram tempos de resposta rápidos, com nítidos aumentos de umidade volumétrica com o início de um evento chuvoso. Elas também apresentaram sensibilidade adequada para serem utilizadas em sistemas de alerta, sendo capazes de registrar alterações de umidade volumétrica com pequenos volumes de chuva. As curvas características encontradas através de ensaios de papel filtro mostraram um bom paralelo entre as sucções medidas diretamente pelo tensiômetro e aquelas obtidas indiretamente pelas sondas tipo TDR, através da conversão das umidades volumétricas em sucção. / [en] The purpose of this work is to evaluate the technical feasibility of using TDR probes and tensiometers to monitor unsaturated slopes. The objective is to monitor with these instruments the variation of matric suction and soil moisture during rainy periods, aiming to improve the warning systems used in hazardous areas and, consequently, to minimize human and material loss. For the measurements, a meteorological station (equipped with a rain gauge, a datalogger, a solar panel and an antenna for data transmission via internet), four TDR-type humidity sensors and a high capacity tensiometer were installed in a slope located in the University of Medicine of Petrópolis, city of the mountainous region of the state of Rio de Janeiro. Approximately three months of data were collected from the TDR probes and only thirteen days of tensiometer data due to a power outage. TDR-type probes showed fast response time, with clear increases in volumetric humidity with the beginning of a rainfall event. They also showed adequate sensitivity to be used in warning systems, being able to register changes in volumetric humidity with small precipitation amounts. The characteristic curves found by the filter method showed a good correlation with the suctions measured directly by the tensiometer and those obtained indirectly by the TDR probes, by converting the volumetric humidity into suction.

Page generated in 0.0431 seconds