• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • Tagged with
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Interações entre a atmosfera e a superfície terrestre: variações da temperatura e umidade na bacia B do Núcleo Cunha (IF) - SP / Interactions between atmosphere and land surface: temperature and humidity variations in Basin B of Núcleo Cunha (IF) - SP

Armani, Gustavo 08 October 2004 (has links)
Os objetivos desta pesquisa são: a) compreender como a temperatura do ar e a umidade relativa na bacia B do Núcleo Cunha (IF) estão relacionadas aos controles climáticos (altitude, declividade e orientação das vertentes, vegetação, a configuração do céu, etc); b) entender qual a importância de cada controle climático nas variações de temperatura e umidade relativa sob a ação de diferentes sistemas atmosféricos. Os controles microclimáticos produzem alterações no ritmo da temperatura e da umidade relativa de diferentes formas e graus de importância em função do sistema atmosférico atuante. Entretanto, a combinação de controles climáticos específicos pode criar ambientes que mantém o ritmo da temperatura e umidade mais estável, independente do sistema atmosférico que estiver atuando. A água no solo desempenha um papel fundamental na minimização das variações da temperatura e da umidade em ambientes específicos. A vegetação também desempenha um papel importante no controle dos valores de umidade relativa, sendo mais relevante que a declividade e a orientação da vertente. As unidades climáticas da Bacia B foram delimitadas como síntese de todas as interações entre os atributos e controles climáticos. O conceito de unidade climática como um espaço onde a interação entre os atributos e controles climáticos tem uma certa homogeneidade, permitiu a delimitação de quatro topoclimas e muitas unidades microclimáticas na bacia B. / The objectives of this work are: a) to undestand how the air temperature and relative humidity in Basin B of Núcleo Cunha (IF) relate to micro and topoclimatic controls (altitude, gradient, slope orientation, vegetation, sky diagram, etc.); b) to comprehend the relative importance of each micro and topoclimatic control in the air temperature and relative humidity variation within different atmospheric systems. Micro and topoclimatic controls influence temperature and relative humidity variation differently in each atmospheric system. However, the arrangement of some specific climatic controls generates environments that conserve the rhythm of temperature and relative humidity, whatever the atmospheric system. Water in the soil has an evident role in the reduction of temperature and relative humidity variation. Vegetation has a fundamental role in the maintenance of the relative humidity, being clearly more importante than gradient and slope orientation. Climatic units of Basin B were delimited as a synsthesis of all interactions. The concept of climate units as a space where climatic attributes and controls keep a relative homogeneity, made possible the identification of four topoclimates and several microclimates units.
2

Influência e correlação de variáveis meteorológicas com infarto agudo do miocárdio e diabetes mellitus.

PEREIRA, Heronides dos Santos. 17 September 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-09-17T12:44:51Z No. of bitstreams: 1 HERONIDES DOS SANTOS PEREIRA - TESE (PPGRN) 2012.pdf: 2978004 bytes, checksum: 87298fe36a826d21fc333216def2bb79 (MD5) / Made available in DSpace on 2018-09-17T12:44:51Z (GMT). No. of bitstreams: 1 HERONIDES DOS SANTOS PEREIRA - TESE (PPGRN) 2012.pdf: 2978004 bytes, checksum: 87298fe36a826d21fc333216def2bb79 (MD5) Previous issue date: 2012-02-29 / As modificações no processo de urbanização das cidades e as mudanças que ocorrem com as variáveis meteorológicas sobre uma região contribuem para maior ocorrência de morbidades. Este trabalho teve o objetivo de estudar a influência e correlação de elementos meteorológicos nos casos de infarto agudo do miocárdio e diabetes mellitus em Campina Grande-PB nos anos de 2000 a 2009, visando entender o comportamento habitual e melhorar o controle sobre essas doenças, mediante as médias mensais de pressão atmosférica, temperatura média do ar, temperaturas máxima e mínima do ar, amplitude térmica, umidade relativa do ar, precipitação pluvial, velocidade do vento, insolação e evaporação. Utilizando-se de dados meteorológicos coletados na estação climatológica principal do Instituto Nacional de Meteorologia localizada na Empresa Brasileira de Pesquisa Agropecuária em Campina Grande (07º13’ Sul, 35º53’ Oeste). Altitude de 543 m e de informações sobre morbidades fornecidas pela Secretaria Municipal de Saúde da Prefeitura Municipal de Campina Grande-PB, este trabalho apresenta correlações que envolvem essas variáveis. Possíveis relações entre as variáveis dependentes e independentes, comprovando a influência do clima nas morbidades estudadas, foram demonstradas, neste estudo, utilizando-se Análise de Componentes Principais. Verificou-se que os elementos meteorológicos influenciam diretamente na incidência do infarto agudo do miocárdio e do diabetes mellitus e que os elementos que mais contribuíram para o aumento do número de casos de infarto agudo do miocárdio são a temperatura máxima do ar e a velocidade do vento. Os casos de diabetes mellitus teve melhor correlação com a precipitação e insolação, contudo, as temperaturas máximas e mínimas do ar também foram grandes responsáveis pelas referidas incidências. Foi verificado também que a insolação foi o principal elemento meteorológico na incidência das morbidades estudadas. / The changes in the cities urbanization process and the changes that occur with meteorological variables over a region contribute to higher incidence of morbidity. This work aimed to study the influence of meteorological elements and its correlation in cases of acute myocardial infarction and diabetes mellitus in Campina Grande-PB in the years 2000 to 2009, in order to understand the normal behavior and improve control of these diseases, by the monthly averages of atmospheric pressure, mean temperature, maximum and minimum temperatures of air, temperature range, relative humidity, rainfall, wind speed, solar radiation and evaporation. Using weather data collected at the main meteorological station of the National Institute of Meteorology located at the Brazilian Enterprise for Agricultural Research in Campina Grande (07 º 13 'South, 35 ° 53' W). Altitude 543 m and information about morbidity provided by the Municipal Health Department of Campina Grande-PB city, this study presents correlations involving these variables. Possible relationships between the dependent and independent variables, showing the influence of climate on the morbidities studied were demonstrated in this study using Principal Component Analysis. It was found that the weather elements directly influence the incidence of acute myocardial infarction and diabetes mellitus and the factors that contributed most to the increase in the number of cases of acute myocardial infarction are the maximum air temperature and wind speed. The cases of diabetes mellitus had better correlation with rainfall and sunshine, however, the maximum and minimum temperatures of air were also largely responsible for these incidents. It was also noticed that sunlight was the main weather element in the incidence of morbidities studied.
3

Interações entre a atmosfera e a superfície terrestre: variações da temperatura e umidade na bacia B do Núcleo Cunha (IF) - SP / Interactions between atmosphere and land surface: temperature and humidity variations in Basin B of Núcleo Cunha (IF) - SP

Gustavo Armani 08 October 2004 (has links)
Os objetivos desta pesquisa são: a) compreender como a temperatura do ar e a umidade relativa na bacia B do Núcleo Cunha (IF) estão relacionadas aos controles climáticos (altitude, declividade e orientação das vertentes, vegetação, a configuração do céu, etc); b) entender qual a importância de cada controle climático nas variações de temperatura e umidade relativa sob a ação de diferentes sistemas atmosféricos. Os controles microclimáticos produzem alterações no ritmo da temperatura e da umidade relativa de diferentes formas e graus de importância em função do sistema atmosférico atuante. Entretanto, a combinação de controles climáticos específicos pode criar ambientes que mantém o ritmo da temperatura e umidade mais estável, independente do sistema atmosférico que estiver atuando. A água no solo desempenha um papel fundamental na minimização das variações da temperatura e da umidade em ambientes específicos. A vegetação também desempenha um papel importante no controle dos valores de umidade relativa, sendo mais relevante que a declividade e a orientação da vertente. As unidades climáticas da Bacia B foram delimitadas como síntese de todas as interações entre os atributos e controles climáticos. O conceito de unidade climática como um espaço onde a interação entre os atributos e controles climáticos tem uma certa homogeneidade, permitiu a delimitação de quatro topoclimas e muitas unidades microclimáticas na bacia B. / The objectives of this work are: a) to undestand how the air temperature and relative humidity in Basin B of Núcleo Cunha (IF) relate to micro and topoclimatic controls (altitude, gradient, slope orientation, vegetation, sky diagram, etc.); b) to comprehend the relative importance of each micro and topoclimatic control in the air temperature and relative humidity variation within different atmospheric systems. Micro and topoclimatic controls influence temperature and relative humidity variation differently in each atmospheric system. However, the arrangement of some specific climatic controls generates environments that conserve the rhythm of temperature and relative humidity, whatever the atmospheric system. Water in the soil has an evident role in the reduction of temperature and relative humidity variation. Vegetation has a fundamental role in the maintenance of the relative humidity, being clearly more importante than gradient and slope orientation. Climatic units of Basin B were delimited as a synsthesis of all interactions. The concept of climate units as a space where climatic attributes and controls keep a relative homogeneity, made possible the identification of four topoclimates and several microclimates units.
4

Avaliação da qualidade ambiental: mercado municipal de São Carlos/SP / Evaluation of environmental quality: municipal market of São Carlos/SP

Silva, Lênin de Matos 30 November 2012 (has links)
O Mercado Municipal de São Carlos é um centro comercial bastante importante, reunindo diversos tipos de lojas e serviços. Um grande número de pessoas frequenta o local diariamente, além de ser o ambiente de trabalho de vários comerciantes. Foi realizado diagnóstico da qualidade do ambiente interno do Mercado Municipal da cidade de São Carlos/SP, através do monitoramento dos seguintes parâmetros: MP10; MP2,5; \'CO IND.2\'; CO; COV; temperatura; umidade relativa e ruído. As coletas de dados foram realizadas durante o ano de 2011. Para todos os parâmetros analisados foram escolhidos 12 pontos amostrais internos e um ponto amostral externo, com exceção do ruído, que teve 9 pontos internos. Os dados amostrais internos de MP10 e de MP2,5 revelaram concentrações médias de 44,55 \'mü\'g/m³ e 31,96 \'mü\'g/m³, respectivamente. As concentrações externas médias foram de 35,60 \'mü\'g/m³ para MP10 e de 25,91 \'mü\'g/m³ para MP2,5. As concentrações médias observadas de material particulado estiveram abaixo dos valores recomendados pela OMS. A razão MP2,5/MP10 esteve acima de 70% indicando predominância de particulado superfino na fração MP10 do material particulado em suspensão. Análises químicas por fluorescência de raios-X foram realizadas no material particulado coletado e os elementos químicos identificados foram: Si, Al, S, Ca, Fe, Ti, Cu, Zn e V. Observou-se que os dados de \'CO IND.2\' ficaram abaixo do limite recomendado pela Resolução ANVISA 09, que é de 800 ppm, os dados internos também foram maiores que os externos. Para o CO e COV, os pontos com maiores concentrações foram os próximos dos acessos ao Mercado pela Rua Episcopal, sendo também maiores os dados internos que o externos. Os dados de temperatura e umidade relativa se mostraram, em geral, fora das faixas de recomendações da Resolução ANVISA 09, o que indica que o ambiente interno do Mercado pode ser desconfortável em relação a esses dois parâmetros. Os níveis internos de ruído observados estiveram acima daqueles recomendados pela Norma Técnica L11.032 (CETESB), que é de 50 dBA. Obteve-se pontos com médias acima de 70 dBA, evidenciando que o local é ruidoso, o que pode acarretar problemas à saúde de seus frequentadores. / The Municipal Market of São Carlos city is a very important commercial center, bringing together different types of shops and services. A large number of people attends the local daily, and it is the work environment of several merchants. A diagnostic of the quality of the indoor environment of the Municipal Market of Sao Carlos/SP was conduct, by monitoring the following parameters: PM10, PM2,5; \'CO IND.2\', CO, VOCs, temperature, humidity and noise. The data collections were performed during the year 2011. For all analyzed parameters were chosen 12 sampling indoor points and an outdoor point, with the exception of noise, which had 9 indoor points. The indoor data of PM10 and PM2,5 showed average concentrations of 44.55 \'mü\'g/m³ and 31.96 \'mü\'g/m³, respectively. The outdoor medium concentrations were 35.60 \'mü\'g/m³ for PM10 and 25.91 \'mü\'g/m³ for PM2,5. The average concentrations of particulate matter observed were below the values recommended by WHO. The reason MP2,5/MP10 was above 70%, indicating the predominance of fine particulate matter at the PM10 fraction. Chemical analysis by X-rays fluorescence was performed in the particulate matter collected and the chemicals identified were: Si, Al, S, Ca, Fe, Ti, Cu, Zn and V. It was observed that the \'CO IND.2\' data were below the limit recommended by ANVISA Resolution 09 which is 800 ppm, the indoor data were also higher than outdoor data. For CO and VOCs, the points with the highest concentrations were the ones near the accesses to the Market by the Episcopal Street, and also higher indoor data that the outdoor. The data of temperature and relative humidity proved generally outside the ranges of the recommendations ANVISA Resolution 09, which indicates that the indoor environment of the market may be uncomfortable considering these two parameters. The indoor noise levels were observed above those recommended by the Technical Standard L11.032 (CETESB), which is 50 dBA. There were some points with averages above 70 dBA, showing that the Market can be a noisy environment, which can cause health problems for their users.
5

DESENVOLVIMENTO E VALIDAÇÃO DE SISTEMAS DE MONITORAMENTO DE BAIXO CUSTO DE TEMPERATURA E UMIDADE RELATIVA DO AR / DEVELOPMENT AND DOWN MONITORING SYSTEMS VALIDATION COST OF TEMPERATURE AND HUMIDITY ON AIR

Rêgo, Márlison de Sá 11 January 2016 (has links)
From the perspective of optimizing the planning, management and management of water resources in the national context the hydrometeorological monitoring systems have gone through the process of technological innovation. Increased monitoring of potential for reduced costs and improved quality of monitored data motivate this field of research. Starting from the importance of the variables of temperature and relative humidity among the variables monitored, this paper proposes the development of three hardware systems and software based on an open platform, which measure these values accurately from three sensors low cost, RHT01, RHT02 and RHT03 available in the market from the year 2005. These sensors are part of the advancement of sensor lines, newly created, polymer and semiconductor oxides. The technological base of each system is the microcontroller "arduino rev. 3 ", which he managed an electronic circuit capable of collecting and storing data from hydro-meteorological variables, in a flash memory device (sd card). Then, in order to check the reliability on the operation, each system was subjected to three data collection tests, at three different sites operating simultaneously with conventional systems used by the Micrometeorology Laboratory of UFSM (LMMET/UFSM). Local tests are situated in the municipality of Santa Maria, in the state of Rio Grande do Sul, Brazil. The microclimate conditions were different among trials due to location. The first test was performed on the terrace of the INPE-UFSM facilities, the second test in micrometeorology Laboratory of UFSM and the third in a rural area of central campus of UFSM, characterized by the pampa biome, which is located a network monitoring tower micro-sulfux. The collections occurred during the months from April to June, representing the final step of the fall season and the beginning of winter in 2015. The first trial lasted eleven days, the second and third Thirteen Eleven. The time discretization of the collections was a minute. With the data collected was carried out comparative analysis of inexpensive and conventional systems by graphic systems for analysis, descriptive statistics, and statistics such as Pearson correlation coefficients, ANOVA and Tukey test. With determination coefficient values (R2) higher than 0.90 in all tests and no significant difference between low-cost sensors and analyzed conventional systems, with only one exception, the results indicated the feasibility of using these sensors to generate Data medium temperature and relative humidity for a minimum time interval from generation 1 minute, 15 minutes, 30 minutes and 1 hour. The results also indicated the possibility of further quantitative research on the influence of the sensors under the measured data. / Na perspectiva de otimizar o planejamento, manejo e gestão dos recursos hídricos no contexto nacional os sistemas de monitoramento hidrometeorológico tem passado pelo processo de inovação tecnológica. O aumento do potencial de monitoramento pela diminuição dos custos e a melhora na qualidade dos dados monitorados motivam esse campo de pesquisa. Partindo-se da relevância das variáveis de temperatura e umidade relativa do ar dentre as variáveis monitoradas, o presente trabalho propõe o desenvolvimento de três sistemas de hardware e software baseados em uma plataforma livre, que meçam essas grandezas com precisão a partir de três sensores de baixo custo, RHT01, RHT02 e RHT03, disponíveis no mercado a partir do ano de 2005. Estes sensores fazem parte do avanço das linhas de sensores, recém-criadas, de polímeros e óxidos semicondutores. A base tecnológica de cada sistema foi o microcontrolador arduino rev. 3 , o qual gerenciou um circuito eletrônico capaz de coletar e armazenar dados das variáveis hidrometeorológicas, em um dispositivo de memória flash ( sd card ). Em seguida, com o objetivo de verificar a confiabilidade quanto ao funcionamento, cada sistema foi submetido a três testes de coleta de dados, em três locais diferentes operando em simultâneo com sistemas convencionais utilizados pelo Laboratório de Micrometeorologia da UFSM (LMMET/UFSM). Os locais dos testes estão situados no município de Santa Maria, no Estado do Rio Grande do Sul, Brasil. As condições de microclima entre os testes eram diferentes em virtude do local. O primeiro teste foi realizado no terraço das instalações do INPE-UFSM, o segundo teste no laboratório de micrometeorologia da UFSM e o terceiro em uma área rural do campus central da UFSM, caracterizada pelo bioma pampa, onde fica localizada uma torre de monitoramento da rede micro-sulfux. As coletas ocorreram durante os meses de abril a junho, correspondendo a etapa final da estação de outono e início do inverno no ano de 2015. O primeiro teste durou onze dias, o segundo treze e o terceiro onze. A discretização temporal das coletas foi de um minuto. Com os dados coletados realizou-se análise comparativa dos sistemas de baixo custo e os sistemas convencionais mediante a análise de gráficos, medidas descritivas, e de estatísticas tais como a correlação linear de Pearson, análise de variância e teste Tukey. Com valores de coeficiente de determinação (R2) superiores a 0,90 em todos os testes e não havendo diferença significativa entre os sensores de baixo custo analisados e o sistemas convencional, com apenas uma única exceção, os resultados indicaram a viabilidade do uso destes sensores para geração de dados médios de temperatura e umidade relativa do ar para intervalo de tempo mínimo de geração de 1 minuto, 15 minutos, 30 minutos e 1 hora. Os resultados também indicaram a possibilidade de pesquisas quantitativas posteriores sobre a influência do abrigo dos sensores nos dados mensurados.
6

Avaliação da qualidade ambiental: mercado municipal de São Carlos/SP / Evaluation of environmental quality: municipal market of São Carlos/SP

Lênin de Matos Silva 30 November 2012 (has links)
O Mercado Municipal de São Carlos é um centro comercial bastante importante, reunindo diversos tipos de lojas e serviços. Um grande número de pessoas frequenta o local diariamente, além de ser o ambiente de trabalho de vários comerciantes. Foi realizado diagnóstico da qualidade do ambiente interno do Mercado Municipal da cidade de São Carlos/SP, através do monitoramento dos seguintes parâmetros: MP10; MP2,5; \'CO IND.2\'; CO; COV; temperatura; umidade relativa e ruído. As coletas de dados foram realizadas durante o ano de 2011. Para todos os parâmetros analisados foram escolhidos 12 pontos amostrais internos e um ponto amostral externo, com exceção do ruído, que teve 9 pontos internos. Os dados amostrais internos de MP10 e de MP2,5 revelaram concentrações médias de 44,55 \'mü\'g/m³ e 31,96 \'mü\'g/m³, respectivamente. As concentrações externas médias foram de 35,60 \'mü\'g/m³ para MP10 e de 25,91 \'mü\'g/m³ para MP2,5. As concentrações médias observadas de material particulado estiveram abaixo dos valores recomendados pela OMS. A razão MP2,5/MP10 esteve acima de 70% indicando predominância de particulado superfino na fração MP10 do material particulado em suspensão. Análises químicas por fluorescência de raios-X foram realizadas no material particulado coletado e os elementos químicos identificados foram: Si, Al, S, Ca, Fe, Ti, Cu, Zn e V. Observou-se que os dados de \'CO IND.2\' ficaram abaixo do limite recomendado pela Resolução ANVISA 09, que é de 800 ppm, os dados internos também foram maiores que os externos. Para o CO e COV, os pontos com maiores concentrações foram os próximos dos acessos ao Mercado pela Rua Episcopal, sendo também maiores os dados internos que o externos. Os dados de temperatura e umidade relativa se mostraram, em geral, fora das faixas de recomendações da Resolução ANVISA 09, o que indica que o ambiente interno do Mercado pode ser desconfortável em relação a esses dois parâmetros. Os níveis internos de ruído observados estiveram acima daqueles recomendados pela Norma Técnica L11.032 (CETESB), que é de 50 dBA. Obteve-se pontos com médias acima de 70 dBA, evidenciando que o local é ruidoso, o que pode acarretar problemas à saúde de seus frequentadores. / The Municipal Market of São Carlos city is a very important commercial center, bringing together different types of shops and services. A large number of people attends the local daily, and it is the work environment of several merchants. A diagnostic of the quality of the indoor environment of the Municipal Market of Sao Carlos/SP was conduct, by monitoring the following parameters: PM10, PM2,5; \'CO IND.2\', CO, VOCs, temperature, humidity and noise. The data collections were performed during the year 2011. For all analyzed parameters were chosen 12 sampling indoor points and an outdoor point, with the exception of noise, which had 9 indoor points. The indoor data of PM10 and PM2,5 showed average concentrations of 44.55 \'mü\'g/m³ and 31.96 \'mü\'g/m³, respectively. The outdoor medium concentrations were 35.60 \'mü\'g/m³ for PM10 and 25.91 \'mü\'g/m³ for PM2,5. The average concentrations of particulate matter observed were below the values recommended by WHO. The reason MP2,5/MP10 was above 70%, indicating the predominance of fine particulate matter at the PM10 fraction. Chemical analysis by X-rays fluorescence was performed in the particulate matter collected and the chemicals identified were: Si, Al, S, Ca, Fe, Ti, Cu, Zn and V. It was observed that the \'CO IND.2\' data were below the limit recommended by ANVISA Resolution 09 which is 800 ppm, the indoor data were also higher than outdoor data. For CO and VOCs, the points with the highest concentrations were the ones near the accesses to the Market by the Episcopal Street, and also higher indoor data that the outdoor. The data of temperature and relative humidity proved generally outside the ranges of the recommendations ANVISA Resolution 09, which indicates that the indoor environment of the market may be uncomfortable considering these two parameters. The indoor noise levels were observed above those recommended by the Technical Standard L11.032 (CETESB), which is 50 dBA. There were some points with averages above 70 dBA, showing that the Market can be a noisy environment, which can cause health problems for their users.
7

Mikroklima archívů / Environment of archives

Onderek, Aleš January 2018 (has links)
The thesis focuses on the way inventories are stored in depositories. Later on, it develops a project of the air-conditioning system in the archive. The last part of the thesis deals with an experiment which examines the interior environment of the depository.
8

Monitoring of Partial Discharges on Cable Terminations : An experimental approach to evaluate non-conventional online PD measurement techniques / Övervakning av partiella urladdningar vid kabeländar : En experimentell utvärdering av icke-konventionella mättekniker

Sibo, Tony January 2023 (has links)
The transmission of electric power over long distances has historically posed challenges. However, the advent of high-voltage engineering has not only addressed distance barriers and power losses in electricity transmission and distribution, but it has also significantly improved the efficiency and transmission capacity of power grids. However, the use of high-voltage techniques has presented new challenges in identifying suitable insulator materials capable of withstanding high electrical stresses associated with elevated voltages. A significant issue arising from these extreme electrical stresses is the occurrence of partial discharges (PDs). Those are electrical sparks or pulses in the magnitude order of pico- or nano-coulombs (pC or nC) emitted from high voltage conductors due to the presence of impurities, contaminants or defects in their insulation system. PDs pose a serious threat to the insulation material due to their aggressive nature in breaking down weak points or links inside the insulation system leading to short-circuit and system failure. Means of offline or conventional testing of power assets against partial discharges has proven to be extremely precise but it is often an unavailable option since it requires a total power shutdown. In this paper, the performance of existing online PD detection techniques is tested and evaluated in terms of performance against conventional PD monitoring methods. Five non-intrusive detectors including an infrared camera (IR-camera), an ultrasonic sensor , a temperature and relative humidity sensor (TRH-sensor), high-frequency current transformer (HFCT sensor) and transient earth voltage antenna (TEV-antenna) were tested in a laboratory experiment for detection of PDs emitted by artificially-created defects inside a medium-voltage cable termination. The results showed varying sensitivity levels among the sensors, with the HFCT sensor demonstrating the highest sensitivity to all types and magnitudes of PDs. The IR-camera and ultrasonic sensor also showed potential, while the TRH-sensor exhibited poor sensitivity. The TEV-antenna had limited reliability. The findings of this study are that the HFCT system proved to be highly reliable for online PD monitoring, followed by the IR-camera and ultrasonic sensor, while the TEV-antenna and TRH-sensor showed lower reliability. In future work, further research on testing the HFCT system on-site can be conducted along with performing longer thermographic detection tests using the IR-camera to further investigate their potential in online PD detection. / Överföring av elektrisk kraft över långa avstånd har historiskt sett varit utmanande. Införandet av högspänningsteknik har inte bara övervunnit avståndsbarriärer och effektförluster vid överföring och distribution av elkraft, utan det har också avsevärt förbättrat kraftnätens effektivitet och överföringskapacitet. Användningen av högspänningsteknik har dock också inneburit nya utmaningar såsom utveckling av lämpliga isoleringsmaterial som tål höga elektriska påfrestningar vid höga spänningar. Ett betydande problem som härrör från dessa extrema elektriska spänningar är förekomsten av partiella urladdningar. Dessa urladdningar identifieras vara elektriska gnistor eller pulser i storleksordningen pico- eller nanocoulombs (pC eller nC) som emitteras från högspänningsledare på grund av närvaron av föroreningar eller defekter i närliggande isoleringssystem. PD:er utgör ett allvarligt hot mot isoleringsmaterialet på grund av deras aggressiva natur för att bryta ner svaga punkter eller länkar i isoleringssystemet, vilket kan leda till kortslutningar och systemfel. Konventionella metoder för att testa nätkomponenter mot partiella urladdningar har visat sig vara extremt noggranna, men detta är ofta inte ett tillgängligt alternativ eftersom det kräver ett totalt strömavbrott för att utföras. I denna studie testades och utvärderades prestandan hos befintliga metoder för online-detektering av partiell urladdning i förhållande till konventionella övervakningsmetoder. Fem icke-invasiva detektorer, inklusive en infraröd kamera, en ultraljudssensor, en temperatur- och relativ fuktighetssensor, en högfrekvent strömtransformator och en transient jordspänningsantenn, testades i ett laboratorieexperiment för att upptäcka partiella urladdningar orsakade av artificiellt skapade defekter i en mellanspänningskabelavslutning. Resultaten visade varierande känslighetsnivåer bland sensorerna, där högfrekventa strömtransformatorn visade den högsta känsligheten för alla typer och storlekar av partiella urladdningar. Den infraröda kameran och ultraljudssensorn visade också potential, medan temperatur- och relativ fuktighetssensorn visade låg känslighet. Den transienta jordspänningsantennen hade begränsad tillförlitlighet. Slutsatsen av denna studie är att den högfrekventa strömtransformatorn visade sig vara mycket tillförlitlig för online-övervakning av partiella urladdningar, följt av den infraröda kameran och ultraljudssensorn, medan den transienta jordspänningsantennen, temperatur- och fuktighetssensorn visade lägre tillförlitlighet. I framtida forskning kan ytterligare undersökningar av det högfrekventa strömtransformatorsystemet utföras på plats, tillsammans med längre termografiska detekteringstester med hjälp av den infraröda kameran för att ytterligare undersöka deras potential för onlinedetektering av partiella urladdningar.

Page generated in 0.1228 seconds