• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 6
  • 6
  • 6
  • 6
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 98
  • 98
  • 59
  • 57
  • 19
  • 17
  • 16
  • 15
  • 15
  • 14
  • 12
  • 12
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da resposta tecidual e capacidade de mineralização de cimentos que contém compostos biocerâmicos, resinosos e com hidróxido de cálcio /

Bueno, Carlos Roberto Emerenciano. January 2015 (has links)
Orientador: Eloi Dezan Junior / Banca: Luciano Tavares Ângelo Cintra / Banca: Marco Antonio Húngaro Duarte / Resumo: A obturação ideal é uma combinação de um cimento com um material sólido, geralmente guta percha, que corrobora com o escoamento do cimento fluido, espalhando-o e preenchendo possíveis espaços vazios. Em virtude da possibilidade de contato direto com os tecidos periapicais, estes cimentos devem ser biocompatíveis e, se possível, estimular a mineralização para proporcionar selamento apical. Com o objetivo de avaliar, in vivo, a resposta tecidual e a capacidade de mineralização dos cimentos endodônticos Smartpaste® Bio, Sealapex® e Acroseal®, foi realizado implante subcutâneo em 40 ratos Wistar e adotados os períodos experimentais de 7, 15, 30 e 60 dias (10 animais por período de tempo). Cada animal recebeu quatro implantes, três tubos de polietileno com os cimentos a serem testados e um tubo vazio como controle. Após cada período pós-operatório, os animais foram eutanasiados e os tubos de polietileno, juntamente com o tecido circunjacente foram removidos e fixados. Para a análise histológica da espessura da cápsula fibrosa, infiltrado inflamatório e mineralização as peças foram incluídas em historresina, e coradas em HE, Von Kossa ou permaneceram sem coloração para a luz polarizada. Os resultados foram submetidos ao teste de Kruskal Wallis e Dunn (p<0,05). Resultados: Todos os cimentos produziram reação inflamatória moderada nos períodos iniciais. O Smartpaste Bio® apresentou a menor reação inflamatória aos 15 dias (p<0,05). O Sealapex® induziu maior mineralização, seguido do Smartpaste Bio®. O Acroseal® não apresentou indução de mineralização. Conclusão: Ao final do experimento, todos os cimentos testados apresentaram compatibilidade tecidual. Com exceção do Acroseal, todos induziram mineralização. / Abstract: The cleaning and shaping of root canals is essential to achieve biological and mechanical goals in the endodontic treatment, providing the appropriate conical shape for subsequent obturation. The optimal obturation is a combination of a sealer with a central core, usually gutta percha, spreading and filling possible gaps. Once there is a direct contact with periapical tissue, the sealer should be biocompatible and, if possible, stimulate mineralization to perform an apical sealing. In order to evaluate in vivo biological response and tissue mineralization capacity of the endodontic sealers Smartpaste Bio® Sealapex® and Acroseal®, subcutaneous implants in 40 Wistar rats were performed. Analisys were at 7, 15, 30 and 60 days experimental periods (10 animals for each time period). Each animal received four implants, three polyethylene tubes with the sealers in test and one empty tube as control. After each post-operative period animals were euthanized and the polyethylene tubes, along with surrounding tissue were removed and fixed. In order to histologically analysis fibrous capsule thickness, inflammatory infiltrate and mineralization, the pieces were included in historesin and stained in HE, Von Kossa or remained without staining for observation under polarized light. The results were statistically analyzed by Kruskal-Wallis and Dunn (p<0,05). Results: All sealers promoted moderate inflammatory reaction at initial periods. Smartpaste Bio® presented the lowest inflammatory reaction at 15 days period (p<0.05). Sealapex® induced higher mineralization, followed by Smartpaste Bio®. Acroseal® showed no mineralization areas. Conclusion: At the end of the experiment, all tested sealers presented biocompatibility. With exception of Acroseal, all induced biomineralization. / Mestre
12

Análise in vitro da proliferação celular e produção de mediadores inflamatórios por células da conjuntiva estimuladas por materiais utilizados na confecção de próteses oculares /

Silva, Emily Vivianne Freitas da. January 2015 (has links)
Orientador: Marcelo Coelho Goiato / Coorientador: Sandra Helena Penha de Oliveira / Banca: Aimée Guiotti / Banca: Rafael Consani / Resumo: A prótese ocular é utilizada para a reabilitação estética e funcional da ausência ocular. O conhecimento da sua biocompatibilidade é importante para a utilização sem reações danosas aos usuários. O objetivo neste estudo foi avaliar a citotoxicidade de materiais utilizados na confecção de próteses oculares, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por células da conjuntiva humana. Inicialmente, foi analisada a influência de diferentes períodos de formação e de exposição dos extratos de resina acrílica branca (N1), termopolimerizada em água aquecida, sobre culturas de células da conjuntiva. Foram confeccionados 24 corpos de prova em resina, sendo 12 para cada período de exposição de células da conjuntiva aos extratos da resina testada (24 e 72 horas). Após a formação dos extratos por 24, 48 e 72 horas de imersão em meio de cultura e, 24 horas em água seguido de 24 horas de imersão em meio, os ensaios propostos foram realizados (n=3). Em seguida, foi avaliado o efeito citotóxico de diferentes métodos de polimerização de resina acrílica N1 em células da conjuntiva. Foram confeccionados 9 corpos de prova em resina (n=3), termopolimerizados em água aquecida, por energia de microondas ou ativados quimicamente, utilizados para a formação dos extratos dessas resinas. Os extratos foram obtidos após 72 horas de imersão dos corpos de prova em meio de cultura e, então, expostos às células da conjuntiva por 72 horas para a realização dos ensaios propostos. Adicionalmente, foi analisada a influência da presença do pigmento acrílico na confecção da prótese de resina acrílica N1, termopolimerizada em água aquecida... / Abstract: Ocular prosthesis is a treatment option for esthetical and functional rehabilitation of ocular absence. The knowledge of ocular prosthesis material's biocompatibility is important to ensure a safe use in patients. The aim of this study was to evaluate the cytotoxic effect of ocular prosthesis materials, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by a human conjunctival cell line. Initially, the influence of different preparation and exposition periods of eluates from heat-polymerized ocular prosthesis N1 color acrylic resin in human conjunctival cell line was evaluated. A total of 24 acrylic resin samples were manufactured and divided into 2 groups, according to the eluate exposition period to conjunctival cell line (24 and 72 hours). Eluates corresponding to 24, 48 and 72 hours of resin sample immersion in medium and, 24 hours of resin sample immersion in water followed by 24 hours of immersion in medium, were prepared (n=3) for the proposed tests. Then, the cytotoxic effect of different polymerization methods of ocular prosthesis N1 color acrylic resin was analyzed. A total of 9 acrylic resin samples were manufactured (n=3), according to the polymerization method: heat-polymerization in water bath, polymerization by microwave energy and auto-polymerization. Eluates corresponding to 72 hours of resin sample immersion in medium were prepared for proposed tests and exposed to conjunctival cell line for 72 hours. Additionally, the influence of pigment incorporation on the cytotoxicity of heat-polymerized ocular prosthesis N1 color acrylic resin was evaluated... / Mestre
13

Estudo comparativo das tensões e microdeformações ao redor de pilares protéticos microunit e ucla sob carregamento axial estático

Santis, Leandro Ruivo de [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:16Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:17Z : No. of bitstreams: 1 000860699.pdf: 2264641 bytes, checksum: 4f5c8ea2c3254608562a9141ab7a55ca (MD5) / O objetivo deste estudo in vitro foi comparar a microdeformação e a concentração de tensões ao redor de implantes, geradas por cargas axiais estáticas, em pilares protéticos microunit e ucla, por meio da extensometria e fotoelasticidade. Foram confeccionados dois blocos em poliuretano, sendo inseridos três implantes de hexágono externo em cada. Os implantes do primeiro bloco receberam pilares protéticos microunit e, nos implantes do segundo bloco, foram instalados pilares protéticos ucla. As respectivas coifas plásticas foram posicionadas sobre os pilares protéticos microunit. As coifas plásticas microunit e ucla foram adaptadas a uma estrutura em resina padronizada e fundidas em liga Ni-Cr. Os blocos foram duplicados em resina fotoelástica. As supraestruturas metálicas foram parafusadas sobre os respectivos pilares protéticos. Os blocos fotoelásticos foram submetidos a uma carga axial de 7,5 kgf usando um dispositivo de aplicação de carga adaptado em polariscópio. Foram colados quatro extensômetros na superfície superior de cada bloco em poliuretano, tangenciando cada um dos implantes. Foi utilizado um dispositivo de aplicação de cargas com carga axial de 30 kgf sobre os pontos A, B e C, durante 10 segundos. Os dados obtidos foram analisados estatisticamente através do teste RM ANOVA dois fatores e teste post hoc de Sidak (p<0,05). Os pilares protéticos ucla apresentaram menores valores médios de microdeformação (597,8 με), quando comparado aos pilares protéticos microunit (988,3 με). O fator pilar foi estatisticamente significante (p <0,0001), o ponto de aplicação da carga não foi estatisticamente significante (p = 0,9437). Os pilares protéticos ucla mostraram padrões de distribuição de tensão semelhantes aos pilares protéticos microunit. O padrão de distribuição das tensões foi diferente no ponto de aplicação de carga B. Em conclusão, a p presença de pilar prótetico convencional interferiu.... / The aim of this in vitro study was to compare microstrain and stress development around implants during axial loading, varying abutment type and load application point, using strain gauge and photoelastic analysis. Two polyurethane blocks were made, being inserted three external hexagon implants each. Microunit abutments were screwed on the first block and UCLA abutments were screwed on the second block. The respective plastic copings were installed onto the microunit abutments. The plastic copings and UCLA abutments were adapted to a standard resin pattern and cast in Ni-Cr alloy. The blocks were replicated in photoelastic resin. The metallic structures were screwed into the microunit abutments and into the implant plataform, respectively. The photoelastic blocks were submitted to a static vertical 7,5 kgf load using a load application device adapted on polariscope. Four strain gauges were bonded to the surface of each polyurethane block, tangetially to each implant. A static vertical 30 kgf load was applied for 10 seconds, using a load application device on points A, B and C. The data were analyzed by two-way RM ANOVA and Sidak's post hoc test (p< 0.05). Ucla abutments showed lower microstrain mean values (597,8 με) when compared to microunit abutments (988,3 με). The abutment factor was statistically significant (p<0.0001), load application point wasn't statistically significant (p=0,9437). UCLA system showed similar stress distribution patterns to conventional abutments. The pattern of stress distribution was different at point B. In conclusion, the presence of conventional prosthetic pillar interfered in stress distribution and microstrain development
14

Análise in vitro da proliferação celular e produção de mediadores inflamatórios por células da conjuntiva estimuladas por materiais utilizados na confecção de próteses oculares

Silva, Emily Vivianne Freitas da [UNESP] 07 April 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-04-07. Added 1 bitstream(s) on 2015-09-17T15:46:23Z : No. of bitstreams: 1 000847893.pdf: 1252256 bytes, checksum: 1fd716895e2784e4359da8659fd760e0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A prótese ocular é utilizada para a reabilitação estética e funcional da ausência ocular. O conhecimento da sua biocompatibilidade é importante para a utilização sem reações danosas aos usuários. O objetivo neste estudo foi avaliar a citotoxicidade de materiais utilizados na confecção de próteses oculares, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por células da conjuntiva humana. Inicialmente, foi analisada a influência de diferentes períodos de formação e de exposição dos extratos de resina acrílica branca (N1), termopolimerizada em água aquecida, sobre culturas de células da conjuntiva. Foram confeccionados 24 corpos de prova em resina, sendo 12 para cada período de exposição de células da conjuntiva aos extratos da resina testada (24 e 72 horas). Após a formação dos extratos por 24, 48 e 72 horas de imersão em meio de cultura e, 24 horas em água seguido de 24 horas de imersão em meio, os ensaios propostos foram realizados (n=3). Em seguida, foi avaliado o efeito citotóxico de diferentes métodos de polimerização de resina acrílica N1 em células da conjuntiva. Foram confeccionados 9 corpos de prova em resina (n=3), termopolimerizados em água aquecida, por energia de microondas ou ativados quimicamente, utilizados para a formação dos extratos dessas resinas. Os extratos foram obtidos após 72 horas de imersão dos corpos de prova em meio de cultura e, então, expostos às células da conjuntiva por 72 horas para a realização dos ensaios propostos. Adicionalmente, foi analisada a influência da presença do pigmento acrílico na confecção da prótese de resina acrílica N1, termopolimerizada em água aquecida... / Ocular prosthesis is a treatment option for esthetical and functional rehabilitation of ocular absence. The knowledge of ocular prosthesis material's biocompatibility is important to ensure a safe use in patients. The aim of this study was to evaluate the cytotoxic effect of ocular prosthesis materials, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by a human conjunctival cell line. Initially, the influence of different preparation and exposition periods of eluates from heat-polymerized ocular prosthesis N1 color acrylic resin in human conjunctival cell line was evaluated. A total of 24 acrylic resin samples were manufactured and divided into 2 groups, according to the eluate exposition period to conjunctival cell line (24 and 72 hours). Eluates corresponding to 24, 48 and 72 hours of resin sample immersion in medium and, 24 hours of resin sample immersion in water followed by 24 hours of immersion in medium, were prepared (n=3) for the proposed tests. Then, the cytotoxic effect of different polymerization methods of ocular prosthesis N1 color acrylic resin was analyzed. A total of 9 acrylic resin samples were manufactured (n=3), according to the polymerization method: heat-polymerization in water bath, polymerization by microwave energy and auto-polymerization. Eluates corresponding to 72 hours of resin sample immersion in medium were prepared for proposed tests and exposed to conjunctival cell line for 72 hours. Additionally, the influence of pigment incorporation on the cytotoxicity of heat-polymerized ocular prosthesis N1 color acrylic resin was evaluated...
15

Avaliação da resposta tecidual e capacidade de mineralização de cimentos que contém compostos biocerâmicos, resinosos e com hidróxido de cálcio

Bueno, Carlos Roberto Emerenciano [UNESP] 17 April 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-04-17. Added 1 bitstream(s) on 2015-09-17T15:46:13Z : No. of bitstreams: 1 000847813.pdf: 1156662 bytes, checksum: e3a0303748f054a31dace31d9b37dea5 (MD5) / A obturação ideal é uma combinação de um cimento com um material sólido, geralmente guta percha, que corrobora com o escoamento do cimento fluido, espalhando-o e preenchendo possíveis espaços vazios. Em virtude da possibilidade de contato direto com os tecidos periapicais, estes cimentos devem ser biocompatíveis e, se possível, estimular a mineralização para proporcionar selamento apical. Com o objetivo de avaliar, in vivo, a resposta tecidual e a capacidade de mineralização dos cimentos endodônticos Smartpaste® Bio, Sealapex® e Acroseal®, foi realizado implante subcutâneo em 40 ratos Wistar e adotados os períodos experimentais de 7, 15, 30 e 60 dias (10 animais por período de tempo). Cada animal recebeu quatro implantes, três tubos de polietileno com os cimentos a serem testados e um tubo vazio como controle. Após cada período pós-operatório, os animais foram eutanasiados e os tubos de polietileno, juntamente com o tecido circunjacente foram removidos e fixados. Para a análise histológica da espessura da cápsula fibrosa, infiltrado inflamatório e mineralização as peças foram incluídas em historresina, e coradas em HE, Von Kossa ou permaneceram sem coloração para a luz polarizada. Os resultados foram submetidos ao teste de Kruskal Wallis e Dunn (p<0,05). Resultados: Todos os cimentos produziram reação inflamatória moderada nos períodos iniciais. O Smartpaste Bio® apresentou a menor reação inflamatória aos 15 dias (p<0,05). O Sealapex® induziu maior mineralização, seguido do Smartpaste Bio®. O Acroseal® não apresentou indução de mineralização. Conclusão: Ao final do experimento, todos os cimentos testados apresentaram compatibilidade tecidual. Com exceção do Acroseal, todos induziram mineralização. / The cleaning and shaping of root canals is essential to achieve biological and mechanical goals in the endodontic treatment, providing the appropriate conical shape for subsequent obturation. The optimal obturation is a combination of a sealer with a central core, usually gutta percha, spreading and filling possible gaps. Once there is a direct contact with periapical tissue, the sealer should be biocompatible and, if possible, stimulate mineralization to perform an apical sealing. In order to evaluate in vivo biological response and tissue mineralization capacity of the endodontic sealers Smartpaste Bio® Sealapex® and Acroseal®, subcutaneous implants in 40 Wistar rats were performed. Analisys were at 7, 15, 30 and 60 days experimental periods (10 animals for each time period). Each animal received four implants, three polyethylene tubes with the sealers in test and one empty tube as control. After each post-operative period animals were euthanized and the polyethylene tubes, along with surrounding tissue were removed and fixed. In order to histologically analysis fibrous capsule thickness, inflammatory infiltrate and mineralization, the pieces were included in historesin and stained in HE, Von Kossa or remained without staining for observation under polarized light. The results were statistically analyzed by Kruskal-Wallis and Dunn (p<0,05). Results: All sealers promoted moderate inflammatory reaction at initial periods. Smartpaste Bio® presented the lowest inflammatory reaction at 15 days period (p<0.05). Sealapex® induced higher mineralization, followed by Smartpaste Bio®. Acroseal® showed no mineralization areas. Conclusion: At the end of the experiment, all tested sealers presented biocompatibility. With exception of Acroseal, all induced biomineralization.
16

Formação de biofilme in vitro e viabilidade de fibroblastos gengivais humanos (FMM-1) em novos materiais cerâmicos /

Dal Piva, Amanda Maria de Oliveira. January 2017 (has links)
Orientador: Marco Antonio Bottino / Coorientadora: Lilian Costa Anami / Banca: Rodrigo Othávio de Assunção e Souza / Banca: Rubens Nisie Tango / Resumo: Este estudo avaliou a morfologia superficial de duas cerâmicas recentemente lançadas no mercado, o crescimento de biofilme heterotípico e a viabilidade de fibroblastos gengivais humanos (FMM-1) em contato com estes materiais após vitrificação ou polimento. Para isto, foram confeccionados 46 blocos (4,5x4,5x1,5 mm) de cada cerâmica: zircônia parcialmente estabilizada por ítria com alta translucidez (HT) e silicato de lítio reforçado por zircônia (SUP). Os blocos foram sinterizados/cristalizados e as superfícies dos espécimes padronizadas com aplicação de glaze (subgrupos "g"). A rugosidade superficial (Ra e RSm) foi mensurada por rugosímetro de contato (n=20) e qualitativamente por perfilometria óptica (n=2). Após esterilização, os espécimes foram contaminados para a formação de biofilme com a associação de S. mutans, S. sanguinis e C. albicans no período de 16 h (n=8) e o biofilme formado foi quantificado através da contagem de unidades formadoras de colônia (UFC) e analisado por microscopia eletrônica de varredura. A viabilidade celular a fibroblastos FMM-1 foi avaliada através do teste MTT. Cinco amostras (15x15x1,5 mm) foram confeccionadas de forma semelhante e utilizadas para determinação da energia livre de superfície (ELS) através de goniometria. Em seguida, os espécimes não-destruídos (n=26) foram resubmetidos ao protocolo de lixamento e então, polidos conforme recomendação do fabricante para avaliação das superfícies polidas (subgrupos "p") sob todas análises em estud... (Resumo completo, clicar acesso eletrônico abaixo) / ABSTRACT : This study evaluated the morphology of two ceramic materials recently introduced on the market, as well as the formation of heterotypic biofilm and the viability of human gingival fibroblasts (FMM-1) in contact with these materials after glazing or polishing. For this, 46 blocks (4.5x4.5x1.5 mm) of each ceramic were made: high translucency zirconia partially stabilized by yttrium (HT) and lithium silicate reinforced by zirconium (SUP). The blocks were sintered/crystallized and surfaces were standardized with glaze application (subgroup "g"). The surface roughness (Ra and RSm) was evaluated through a contact rugosimeter (n=20) and qualitatively by profilometry (n=2). After sterilization, specimens were contaminated for heterotypic biofilm formation with association of S. mutans, S. sanguinis and C. albicans during 16 h of formation (n=8) and the biofilm was quantified by counting the colony forming units (CFU/mL) and analyzed by scanning electron microscopy (SEM). The viability of FMM-1 fibroblasts was evaluated by MTT assay. 5 samples (15x15x1.5 mm) were prepared in a similar way and used to determine the surface free energy (SFE) by goniometry. Then, the non-destroyed specimens (n=26) were resubmitted to the sandpaper polishing and finished as recommended by the manufacturer to evaluate the polished surfaces (subgroup "p") under all analyzes in study. Roughness data was evaluated using the nonparametric Kruskal-Wallis, Dunn and Mann-Whitney tests. SFE, MTT and....(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
17

Avaliação da resposta tecidual a cimentos cirúrgicos : estudo histológico realizado em alvéolo dental de ratos /

Saito, Célia Tomiko Matida Hamata. January 2005 (has links)
Orientador: Pedro Felício Estrada Bernabé / Banca: Letícia Helena Theodoro / Banca: João Eduardo Gomes Filho / Resumo: Os materiais odontológicos estão presentes em todas as especialidades. Na periodontia, aliado a uma técnica cirúrgica criteriosa, os cimentos cirúrgicos são materiais que ocupam posição importante. A proposta deste estudo foi avaliar a intensidade da resposta inflamatória e a deposição óssea em alvéolos de ratos após o implante dos cimentos cirúrgicos Coe-pak®, Perio Bond® e Voco pac®. Seguindo a remoção dos incisivos superiores direitos de 84 ratos machos (Rattus norvegicus albinus, Wistar), implantou-se em cada alvéolo um tubo de polietileno dos quais 63 estavam preenchidos com os cimentos e os restantes 21 tubos estavam vazios, compondo o grupo controle. A avaliação histológica considerou o número de células inflamatórias, a neoformação angioblástica, a densidade de fibroblastos e a presença e localização da deposição de tecido ósseo nos períodos pós-operatórios de 7, 14 e 28 dias. A análise estatística dos dados obtidos foi realizada utilizando-se Análise de Variância e teste de Krukal-Wallis. No critério infiltrado inflamatório, aos 28 dias, houve diferença estática significativa (p<0,01) entre o cimento Voco pac® e o grupo controle. Quanto à presença e localização da deposição de tecido ósseo houve diferença no grupo controle, comparando os períodos de 7 e 28 dias (p<0,01). Na associação de todos os critérios avaliados, o cimento Perio Bond® apresentou resultado menos favorável, significativamente diferente (p<0,01) do grupo controle. Respeitadas as condições experimentais deste estudo, pode-se concluir que o cimento Voco pac® evidenciou aos 28 dias maior número de células inflamatórias; enquanto cimentos Coe-pak® e Perio Bond® demonstraram comportamentos semelhantes ao grupo controle e considerando-se a associação dos resultados de todos os critérios nos períodos analisados neste estudo, o cimento Perio Bond®... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this investigation was to investigate the inflammatory tissue reaction and bone deposition in rat's dental sockets in the presence of three periodontal dressing (Coe-pak®, Perio Bond® e Voco pac®). After the exodontic removal of the right upper incisors of the eighty-four male rats, one polyethylene tube was implanted in each dental socket. Twenty one of these were empty and the other sixty-three tubes were fulfilled with periodontal dressings. The number of inflammatory cells, angioblastic neoformation, fibroblastic density and bone neoformation were evaluated after 7, 14 and 28 days. Significant differences (p<0.05) were observed in the number of inflammatory cells at 28 days, when Voco pac® was implanted. Considering bone neoformation, there was significant difference (p<0.01) between 7 and 28 days, in control group. When all events evaluated were associated, Perio Bond® showed the most severe response, which was staticcally different (p<0.01) from the control group. The following conclusions were obtained: after 28 days, Voco pac® presented at 28 days the greater number of inflammatory cells, while Coe-pak® and Perio Bond® periodontal dressings showed same number of the control group and when all events an periods of time were associated, Perio Bond® showed the most severe inflammatory response. / Mestre
18

Estudo comparativo das tensões e microdeformações ao redor de pilares protéticos microunit e ucla sob carregamento axial estático /

Santis, Leandro Ruivo de January 2015 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: Rodrigo Tiossi / Resumo: O objetivo deste estudo in vitro foi comparar a microdeformação e a concentração de tensões ao redor de implantes, geradas por cargas axiais estáticas, em pilares protéticos microunit e ucla, por meio da extensometria e fotoelasticidade. Foram confeccionados dois blocos em poliuretano, sendo inseridos três implantes de hexágono externo em cada. Os implantes do primeiro bloco receberam pilares protéticos microunit e, nos implantes do segundo bloco, foram instalados pilares protéticos ucla. As respectivas coifas plásticas foram posicionadas sobre os pilares protéticos microunit. As coifas plásticas microunit e ucla foram adaptadas a uma estrutura em resina padronizada e fundidas em liga Ni-Cr. Os blocos foram duplicados em resina fotoelástica. As supraestruturas metálicas foram parafusadas sobre os respectivos pilares protéticos. Os blocos fotoelásticos foram submetidos a uma carga axial de 7,5 kgf usando um dispositivo de aplicação de carga adaptado em polariscópio. Foram colados quatro extensômetros na superfície superior de cada bloco em poliuretano, tangenciando cada um dos implantes. Foi utilizado um dispositivo de aplicação de cargas com carga axial de 30 kgf sobre os pontos A, B e C, durante 10 segundos. Os dados obtidos foram analisados estatisticamente através do teste RM ANOVA dois fatores e teste post hoc de Sidak (p<0,05). Os pilares protéticos ucla apresentaram menores valores médios de microdeformação (597,8 με), quando comparado aos pilares protéticos microunit (988,3 με). O fator pilar foi estatisticamente significante (p <0,0001), o ponto de aplicação da carga não foi estatisticamente significante (p = 0,9437). Os pilares protéticos ucla mostraram padrões de distribuição de tensão semelhantes aos pilares protéticos microunit. O padrão de distribuição das tensões foi diferente no ponto de aplicação de carga B. Em conclusão, a p presença de pilar prótetico convencional interferiu.... / Abstract: The aim of this in vitro study was to compare microstrain and stress development around implants during axial loading, varying abutment type and load application point, using strain gauge and photoelastic analysis. Two polyurethane blocks were made, being inserted three external hexagon implants each. Microunit abutments were screwed on the first block and UCLA abutments were screwed on the second block. The respective plastic copings were installed onto the microunit abutments. The plastic copings and UCLA abutments were adapted to a standard resin pattern and cast in Ni-Cr alloy. The blocks were replicated in photoelastic resin. The metallic structures were screwed into the microunit abutments and into the implant plataform, respectively. The photoelastic blocks were submitted to a static vertical 7,5 kgf load using a load application device adapted on polariscope. Four strain gauges were bonded to the surface of each polyurethane block, tangetially to each implant. A static vertical 30 kgf load was applied for 10 seconds, using a load application device on points A, B and C. The data were analyzed by two-way RM ANOVA and Sidak's post hoc test (p< 0.05). Ucla abutments showed lower microstrain mean values (597,8 με) when compared to microunit abutments (988,3 με). The abutment factor was statistically significant (p<0.0001), load application point wasn't statistically significant (p=0,9437). UCLA system showed similar stress distribution patterns to conventional abutments. The pattern of stress distribution was different at point B. In conclusion, the presence of conventional prosthetic pillar interfered in stress distribution and microstrain development / Mestre
19

Avaliação da reação tecidual frente aos cimentos MTA Ângelus® cinza e um MTA fotopolimerizável experimental : análise microscópica em alvéolos dentários de ratos /

Costa, Mariana Machado Teixeira de Moraes. January 2008 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Robson Frederico Cunha / Banca: Ivaldo Gomes de Moraes / Banca: Fabíola Lemos Melhado / Banca: Roberta Okamoto / Resumo: Para contornar algumas dificuldades de manipulação do agregado de trióxido mineral (MTA) convencional, um MTA fotopolimerizável vem sendo desenvolvido. Desta forma, o objetivo do presente estudo foi avaliar a resposta tecidual frente ao uso deste material. Para isso, 57 tubos de polietileno preenchidos com o MTA experimental e o MTA cinza foram implantados em alvéolos de ratos. Como grupo controle, foram implantados tubos vazios. Os animais foram sacrificados após 30, 60 e 90 dias, sendo realizada a análise microscópica dos cortes obtidos e corados com Hematoxilina e Eosina. Foi possível concluir que o MTA fotopolimerizável apresentou uma resposta semelhante ao MTA cinza, caracterizada pela ausência de uma inflamação severa e pela deposição de tecido mineralizado em contato com o material. / Abstract: The aim of this study was to evaluate the tissue reaction to a Light Cured MTA or MTA Ângelus® gray. It was used 57 animals, which were divided in three groups. In the Control Group, empty tubes were inserted into the rat's sockets immediately after extraction. In the other groups, the tubes were filled with Light Cured MTA or MTA Ângelus®. After 30, 60 and 90 days after the implantation, the animals were sacrificed and the right hemi-maxilas were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6μm thickness and stained with HE. It was possible to conclude that Light Cured MTA presented a similar response when compared to MTA Ângelus®, being characterized by a mild inflammatory response and dystrophic calcifications areas. Despite of a favorable healing process obtained with this new experimental MTA, further studies should be conducted to elucidate these material properties and confirm the present results. / Doutor
20

Avaliação da resposta tecidual em ratos, a microrganismos anaeróbios e facultativos inativados associados a soluções preparadas com extratos vegetais aquoso e hidroalcoólico de Araçá (Psidium cattleianum) : análise edemogênica e microscópica /

Ruviére, Denise Belucio. January 2008 (has links)
Resumo: O objetivo do presente estudo foi avaliar, in vivo, a resposta biológica imediata e tardia de soluções aquosa e hidroalcoólica preparadas com extrato vegetal de Araçá (Psidium cattleianum) associadas a microrganismos inativados. O controle utilizado foi soro fisiológico associado aos microrganismos inativados. Foi utilizado 0,1mL de uma suspensão contendo Porphyromonas gingivalis ATCC 33277, Prevotella intermedia ATCC 25611, Fusobacterium nucleatum ATCC 25586, Enterococcus faecalis ATCC 29212, Peptostreptococcus micros ATCC 33270 e Porphyromonas endodontalis ATCC 35406 inativados por calor, a qual foi misturada a 1mL de soro fisiológico ou solução aquosa ou hidroalcoólica de araçá. Para a análise edemogênica (resposta imediata), foram utilizados 18 ratos machos (Rattus norvegicus). Sob anestesia geral, os animais receberam injeção intravenosa de azul de Evans a 1%. Após 30 minutos, foi injetado 0,1mL da mistura de uma das soluções ou soro (associados aos microrganismos inativados), na região subcutânea dorsal. Os animais foram sacrificados após 3 e 6 horas e as peças obtidas colocadas em formamida por 72 horas. A leitura da análise edemogênica foi realizada em espectrofotômetro com comprimento de onda de 630ηm. Para a análise microscópica (resposta tardia), tubos de polietileno contendo as soluções ou soro fisiológico acrescidos da solução de microrganismos inativados foram implantados na região dorsal de 30 ratos machos, que foram mortos após 7 e 30 dias. Não foi observada diferença significante (p>0,05) na quantidade de edema dos diferentes grupos nos tempos pós-operatórios. Os resultados obtidos pela leitura das lâminas em microscópio óptico apontaram reparo no período de 30 dias significativamente superior ao de 7 dias... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate, in vivo, the immediate and late biological reactions of hydro alcoholic and watery solutions prepared with vegetable extract of Araça (Psidium cattleianum), associated to inactivated microorganisms. For the control group, physiological serum, associated to inactivated microorganisms, was used. For performing the investigation it was used 0.1mL of a suspension containing Porphyromonas gingivalis ATCC 33277, Prevotella intermedia ATCC 25611, Fusobacterium nucleatum ATCC 25586, Enterococcus faecalis ATCC 29212, Peptostreptococcus micros ATCC 33270 and Porphyromonas endodontalis ATCC 35406, inactivated by heat, which was mixed to 1mL of physiological serum or watery solution or hydro alcoholic extract of Araça. For the edemogenic analysis (immediate reaction), 18 male mice (Rattus norvegicus) were used. The animals, under general anesthesia, received Evans blue intra shot at 1%. Thirty (30) minutes later, 0,1mL of one of the extracts or the serum - associated to the inactivated microorganisms - was injected on the animal dorsal under skin region. The animals were sacrificed after 3 and 6 hours and the materials obtained were placed into formamide for 72 hours. The edemogenic analysis reading was made by spectrophotometer with 630ηm wavelength. For the morphological analysis (late reaction), 30 mice received implant of polyethylene duct with the extracts or the serum, added by the solution of inactivated microorganisms on the dorsal region, and after 7 and 30 days they were sacrificed. No significant difference (p>0,05) in the edema amount of the different groups was observed postoperatively. Results obtained from the reading of species, in optical microscopy, showed a repair in the 30-day-period, which was significantly superior when compared to the 7-day-period (p<0,0001)... (Complete abstract click electronic access below) / Orientador: Eloi Dezan Júnior / Coorientador: Elerson Gaetti Jardim Júnior / Banca: Ana Cláudia Okamoto / Banca: Leda Maria Pescinini Salzedas / Banca: Maria Aparecida de Andrade Moreira Machado / Banca: Fábio Luiz Camargo Villela / Doutor

Page generated in 0.5295 seconds