• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da autoxidação dos complexos de Cu(II), Ni(II) e Co(II)/tetraglicina induzida por S(IV) / Study of the autoxidation of the complexes of Cu (II), Ni (II) and Co (II)/tetraglycine induced by S(IV)

Sebastian, Maria Vespertina Alipazaga 19 September 2003 (has links)
O presente trabalho apresenta estudos espectrofotométricos relacionados à autoxidação dos complexos de Cu(II), Ni(II) e Co(II)/tetraglicina induzida por sulfito. Nossos estudos verificaram que a autoxidação de Cu(II)/tetraglicina (1,0x10-3 mol L-1) em pH = 9,0 (tampão borato) é afetada pela presença de traços de Ni(II) ou Co(II). Na ausência de Ni(II) ou Co(II), a reação é muito ineficiente e lenta com períodos de indução longos (aproximadamente 4 h). Ni(II) ou Co( II) em concentrações baixas ( 10-5 - 10-6 mol L-1) afetam significativamente a cinética: o período de indução diminui drasticamente (a menos de 2 s) e a formação de Cu(III) é fortemente acelerada com simultâneo aumento da eficiência da reação. A atividade catalítica e o sinergismo positivo de Co(II) e Ni(II) podem ser explicados pela oxidação mais rápida de Co(II) ou Ni(II)/tetraglicina pelo oxigênio dissolvido. O processo eletroquímico relacionado aos sistemas Cu(II)/Cu(III)/tetraglicina e Ni(II)/Ni(III)/tetraglicina são reversíveis, possibilitando monitorá-los adequadamente mediante o uso da técnica de eletrodo rotativo disco-anel. Entretanto, o sistema Co(II)/Co(III)/tetraglicina é irreversível. Esses estudos mostraram que as espécies de Cu(III) e Ni(III) geradas no eletrodo disco são instáveis nas condições experimentais empregadas. O efeito sinérgico positivo na presença de Ni(II) (que permitiu aumentar a sensibilidade) foi aproveitado para desenvolvimento de método espectrofotométrico e amperométrico simples e sensível para a determinação indireta de sulfito em meio aquoso. O método espectrofotométrico está baseado na medida de absorbância do complexo de Cu(III)/tetraglicina (gerado na presença de sulfito e traços de Ni(II)) em 365 nm. O método amperométrico em análise por injeção em fluxo baseia-se na medida de corrente (0,1 V vs Ag/AgCl) em função da concentração de Cu(III)/tetraglicina gerado quimicamente, na presença de sulfito e traços de Ni(II). Os métodos desenvolvidos foram empregados para a determinação de S(IV), em vinhos e sucos, após a sua extração da amostra acidificada, os resultados obtidos concordaram com aqueles obtidos pelo método iodométrico. / The present work presents spectrophotometric studies related to the sulfite induced autoxidation of Cu(II), Ni(II) and Co(II)/tetraglycine complexes. The sulfite induced autoxidação of Cu(II)/tetraglycine (1.0x10-3 mol L-1) at pH = 9.0 (borate buffer) is affected by the presence of small quantities of the Ni(II) or Co(II). In the absence of added nickel (II) or cobalt (II), the reaction is very inefficient and slow with one large induction period (about 4 h). Trace amounts of Ni(II) or Co(II) (10-5 - 10-6 M) affect the kinetic significantly: the induction period drastically decreases (less than 2 s) and the formation of Cu(III) is strongly accelerated. The effectiveness of Cu(III) formation becomes much higher. The catalytic activity and the positive synergism of Co(II) and Ni(II) may be explained by the faster oxidation of Co(II) or Ni(II)/tetraglycine complexes by dissolved oxygen. The electrochemistry of Cu(II)/Cu(III)/tetraglycine and Ni(II)/Ni(III)/tetraglycine systems are reversible, such as it was possible to monitor them by using the rotating ring-disk electrode technique. However, the Co(II)/Co(III)/tetraglycine system is irreversible. Those studies showed that the Cu(III) and Ni(III) species generated on the disk electrode are unstable in the employed experimental conditions. The positive sinergistic effect in the presence of Ni(II) (which allowed to increase the sensibility) was taken in advantage for development of one simple and sensitive spectrophotometric and amperometric method for indirect determination of sulfite in aqueous medium. The spectrophotometric method is based on the absorbance measurement of the Cu(III)/tetraglicyne complex (generated in the presence of sulfite and small quantities of Ni(II)) at 365 nm. The amperometric method by flow injection analysis is based on the current measurement (0.1 V vs Ag/AgCl) as function of Cu(III)/tetraglycine concentration chemically generated, in the presence of sulfite and Ni(II). The methods were employed for the determination of S(IV), in wines and juices, after its extraction from acidified samples and the results were in agreement with those obtained by the iodometric procedure.
2

Estudo da autoxidação dos complexos de Cu(II), Ni(II) e Co(II)/tetraglicina induzida por S(IV) / Study of the autoxidation of the complexes of Cu (II), Ni (II) and Co (II)/tetraglycine induced by S(IV)

Maria Vespertina Alipazaga Sebastian 19 September 2003 (has links)
O presente trabalho apresenta estudos espectrofotométricos relacionados à autoxidação dos complexos de Cu(II), Ni(II) e Co(II)/tetraglicina induzida por sulfito. Nossos estudos verificaram que a autoxidação de Cu(II)/tetraglicina (1,0x10-3 mol L-1) em pH = 9,0 (tampão borato) é afetada pela presença de traços de Ni(II) ou Co(II). Na ausência de Ni(II) ou Co(II), a reação é muito ineficiente e lenta com períodos de indução longos (aproximadamente 4 h). Ni(II) ou Co( II) em concentrações baixas ( 10-5 - 10-6 mol L-1) afetam significativamente a cinética: o período de indução diminui drasticamente (a menos de 2 s) e a formação de Cu(III) é fortemente acelerada com simultâneo aumento da eficiência da reação. A atividade catalítica e o sinergismo positivo de Co(II) e Ni(II) podem ser explicados pela oxidação mais rápida de Co(II) ou Ni(II)/tetraglicina pelo oxigênio dissolvido. O processo eletroquímico relacionado aos sistemas Cu(II)/Cu(III)/tetraglicina e Ni(II)/Ni(III)/tetraglicina são reversíveis, possibilitando monitorá-los adequadamente mediante o uso da técnica de eletrodo rotativo disco-anel. Entretanto, o sistema Co(II)/Co(III)/tetraglicina é irreversível. Esses estudos mostraram que as espécies de Cu(III) e Ni(III) geradas no eletrodo disco são instáveis nas condições experimentais empregadas. O efeito sinérgico positivo na presença de Ni(II) (que permitiu aumentar a sensibilidade) foi aproveitado para desenvolvimento de método espectrofotométrico e amperométrico simples e sensível para a determinação indireta de sulfito em meio aquoso. O método espectrofotométrico está baseado na medida de absorbância do complexo de Cu(III)/tetraglicina (gerado na presença de sulfito e traços de Ni(II)) em 365 nm. O método amperométrico em análise por injeção em fluxo baseia-se na medida de corrente (0,1 V vs Ag/AgCl) em função da concentração de Cu(III)/tetraglicina gerado quimicamente, na presença de sulfito e traços de Ni(II). Os métodos desenvolvidos foram empregados para a determinação de S(IV), em vinhos e sucos, após a sua extração da amostra acidificada, os resultados obtidos concordaram com aqueles obtidos pelo método iodométrico. / The present work presents spectrophotometric studies related to the sulfite induced autoxidation of Cu(II), Ni(II) and Co(II)/tetraglycine complexes. The sulfite induced autoxidação of Cu(II)/tetraglycine (1.0x10-3 mol L-1) at pH = 9.0 (borate buffer) is affected by the presence of small quantities of the Ni(II) or Co(II). In the absence of added nickel (II) or cobalt (II), the reaction is very inefficient and slow with one large induction period (about 4 h). Trace amounts of Ni(II) or Co(II) (10-5 - 10-6 M) affect the kinetic significantly: the induction period drastically decreases (less than 2 s) and the formation of Cu(III) is strongly accelerated. The effectiveness of Cu(III) formation becomes much higher. The catalytic activity and the positive synergism of Co(II) and Ni(II) may be explained by the faster oxidation of Co(II) or Ni(II)/tetraglycine complexes by dissolved oxygen. The electrochemistry of Cu(II)/Cu(III)/tetraglycine and Ni(II)/Ni(III)/tetraglycine systems are reversible, such as it was possible to monitor them by using the rotating ring-disk electrode technique. However, the Co(II)/Co(III)/tetraglycine system is irreversible. Those studies showed that the Cu(III) and Ni(III) species generated on the disk electrode are unstable in the employed experimental conditions. The positive sinergistic effect in the presence of Ni(II) (which allowed to increase the sensibility) was taken in advantage for development of one simple and sensitive spectrophotometric and amperometric method for indirect determination of sulfite in aqueous medium. The spectrophotometric method is based on the absorbance measurement of the Cu(III)/tetraglicyne complex (generated in the presence of sulfite and small quantities of Ni(II)) at 365 nm. The amperometric method by flow injection analysis is based on the current measurement (0.1 V vs Ag/AgCl) as function of Cu(III)/tetraglycine concentration chemically generated, in the presence of sulfite and Ni(II). The methods were employed for the determination of S(IV), in wines and juices, after its extraction from acidified samples and the results were in agreement with those obtained by the iodometric procedure.
3

Estabilização de Cu(III) em meio contendo peptídeos: estudos eletroquímicos e aplicações analíticas / Stabilization of Cu (III) in medium containing peptides: electrochemical studies and analytical applications

Lowinsohn, Denise 05 May 2003 (has links)
Neste trabalho são apresentados alguns resultados relacionados a estudos sobre o comportamento eletroquímico do Cu(II) em meio contendo diferentes peptídeos (tri, tetra e pentaglicina) em função da acidez utilizando-se voltametria cíclica. Os experimentos foram realizados em uma faixa de pH entre 7,0 e 10,0. Experimentos espectrofotométricos e coulométricos também foram feitos, ambos para se caracterizar as espécies de Cu(II) e Cu(III) em solução e provar a existência da degradação dos complexos de Cu(III). Além disso, experimentos para esses sistemas também foram realizados em diferentes temperaturas utilizando eletrodo rotativo na configuração disco-anel. Estudos eletroanalíticos demonstraram a potencialidade de se empregar o sistema Cu(II)/Cu(III) no desenvolvimento de metodologia eletroanalítica para a determinação de sulfito. Neste contexto, um método amperométrico indireto para a determinação de sulfito em fluxo é proposto neste trabalho. O método baseia-se na medida amperométrica (OV vs Ag/AgCI (sat. NaCI)) do Cu(III) gerado quimicamente no processo de auto¬-oxidação do S(IV) em soluções de Cu(II)/tetraglicina na presença de traços de Ni(II) utilizando uma célula em fluxo com sistema adequado para separação de gases. A oxidação espontânea do complexo pelo oxigênio dissolvido e S(IV) é muito lenta ao contrário do que ocorre quando há traços de Ni(II). A faixa de trabalho foi de 20-100 µmoIL-1 com limite de detecção de 2µmoIL-1 (S/N=3). A repetibilidade para a determinação (100µmoIL-1) levou a um desvio de 4,9% (n = 38), valor superior aos encontrados na literatura para determinações de sulfito em vinho por FIA com detecção amperométrica indireta (1-4,6%), e a freqüência analítica foi de 40h-1, valor coerente com os dos outros métodos amperométricos. Ambas as análises de sulfito em amostras de vinhos e de sucos tiveram seus resultados comparados com aqueles obtidos utilizando-se o método padrão. / The electrochemistry of Cu(II) in aqueous solutions containing triglycine, tetraglycine and pentaglycine had been investigated at glassy carbon surfaces. Experiments were carried out in the pH range between 7.0 and 10.0. A correlation between voltammetric waves and the nature of the Cu(II) species involved in the electrochemical steps was performed. Spectrophotometric and coulometric studies were also done to characterise Cu(II) and Cu(III) species in solution and prove the existence of a degradation step related to Cu(III) complexes. Rotating ring-disc voltammetry was employed to follow this chemical step coupled to the electrode reaction, at three different temperatures. Data show that Cu(III)/triglycine species degrade, with faster kinetics, when the results are compared with those obtained for tetraglycine and pentaglycine. An indirect amperometric method for the determination of sulfite in a flow injection configuration is described. The method is based on the amperometric measurement (OV vs Ag/AgCI (sat. NaCI)) of Cu(III) chemically generated by the sulfite induced autoxidation of Cu(II)/tetraglycine complex in the presence of traces of Ni(II) with a manifold that incorporates flow extraction of sulfite as SO2 through a PTFE membrane. The operational range was 2µmoIL-1 with a detection limit of 2µmolL-1 (S/N = 3). The repeatability for the determination (100 2µmolL-1) was evaluated to be 4.9% (n = 20) and the analytical frequency was 40h-1. Results for 3 wines and 2 juices samples showed excellent agreement with those obtained by using a recommended procedure for sulfite analysis.
4

Estabilização de Cu(III) em meio contendo peptídeos: estudos eletroquímicos e aplicações analíticas / Stabilization of Cu (III) in medium containing peptides: electrochemical studies and analytical applications

Denise Lowinsohn 05 May 2003 (has links)
Neste trabalho são apresentados alguns resultados relacionados a estudos sobre o comportamento eletroquímico do Cu(II) em meio contendo diferentes peptídeos (tri, tetra e pentaglicina) em função da acidez utilizando-se voltametria cíclica. Os experimentos foram realizados em uma faixa de pH entre 7,0 e 10,0. Experimentos espectrofotométricos e coulométricos também foram feitos, ambos para se caracterizar as espécies de Cu(II) e Cu(III) em solução e provar a existência da degradação dos complexos de Cu(III). Além disso, experimentos para esses sistemas também foram realizados em diferentes temperaturas utilizando eletrodo rotativo na configuração disco-anel. Estudos eletroanalíticos demonstraram a potencialidade de se empregar o sistema Cu(II)/Cu(III) no desenvolvimento de metodologia eletroanalítica para a determinação de sulfito. Neste contexto, um método amperométrico indireto para a determinação de sulfito em fluxo é proposto neste trabalho. O método baseia-se na medida amperométrica (OV vs Ag/AgCI (sat. NaCI)) do Cu(III) gerado quimicamente no processo de auto¬-oxidação do S(IV) em soluções de Cu(II)/tetraglicina na presença de traços de Ni(II) utilizando uma célula em fluxo com sistema adequado para separação de gases. A oxidação espontânea do complexo pelo oxigênio dissolvido e S(IV) é muito lenta ao contrário do que ocorre quando há traços de Ni(II). A faixa de trabalho foi de 20-100 µmoIL-1 com limite de detecção de 2µmoIL-1 (S/N=3). A repetibilidade para a determinação (100µmoIL-1) levou a um desvio de 4,9% (n = 38), valor superior aos encontrados na literatura para determinações de sulfito em vinho por FIA com detecção amperométrica indireta (1-4,6%), e a freqüência analítica foi de 40h-1, valor coerente com os dos outros métodos amperométricos. Ambas as análises de sulfito em amostras de vinhos e de sucos tiveram seus resultados comparados com aqueles obtidos utilizando-se o método padrão. / The electrochemistry of Cu(II) in aqueous solutions containing triglycine, tetraglycine and pentaglycine had been investigated at glassy carbon surfaces. Experiments were carried out in the pH range between 7.0 and 10.0. A correlation between voltammetric waves and the nature of the Cu(II) species involved in the electrochemical steps was performed. Spectrophotometric and coulometric studies were also done to characterise Cu(II) and Cu(III) species in solution and prove the existence of a degradation step related to Cu(III) complexes. Rotating ring-disc voltammetry was employed to follow this chemical step coupled to the electrode reaction, at three different temperatures. Data show that Cu(III)/triglycine species degrade, with faster kinetics, when the results are compared with those obtained for tetraglycine and pentaglycine. An indirect amperometric method for the determination of sulfite in a flow injection configuration is described. The method is based on the amperometric measurement (OV vs Ag/AgCI (sat. NaCI)) of Cu(III) chemically generated by the sulfite induced autoxidation of Cu(II)/tetraglycine complex in the presence of traces of Ni(II) with a manifold that incorporates flow extraction of sulfite as SO2 through a PTFE membrane. The operational range was 2µmoIL-1 with a detection limit of 2µmolL-1 (S/N = 3). The repeatability for the determination (100 2µmolL-1) was evaluated to be 4.9% (n = 20) and the analytical frequency was 40h-1. Results for 3 wines and 2 juices samples showed excellent agreement with those obtained by using a recommended procedure for sulfite analysis.
5

Estudos de lesão ao DNA promovida pela autoxidação de S(IV) na presença de complexos de Cu(III)/tetraglicina. Efeito sinérgico de Ni(II), Co(II) e Mn(II) / Studies of DNA damage induced by sulfite autoxidation in the presence of Cu(II)/tetraglycine complexes. Effect synergistic of Ni(II), Co(II) and Mn(II).

Moreno, Ruben Gregorio Moreno 09 December 2005 (has links)
O presente trabalho apresenta estudos de lesão em biomoléculas (DNA e 2\'-deoxiguanosina) induzida por Cu(III)/tetraglicina (Cu(III)/G4), radicais de óxidos de enxofre (SO3·-, SO4·-, SO5·-), HO· e HSO5-, espécies estas geradas durante a autoxidação de S(IV) na presença de Cu(II)/G4 ou Cu(II) (ausência de tetraglicina) e traços de um segundo íon metálico (Ni(II), Co(II) ou Mn(II)). A formação dos radicais SO3·- e HO· foi detectada pela técnica de ressonância paramagnética eletrônica (EPR). As técnicas de espectrofotometria e dicroísmo circular foram empregadas para avaliar a formação de Cu(III)/G4 em diferentes condições experimentais, na presença e ausência de S(IV), e a interação entre os complexos de cobre (II)/(III) e a molécula de DNA. A eficiência da formação de Cu(III) depende da acidez, concentração de S(IV) e dos tampões utilizados. A lesão no DNA plasmidial pUC19 foi verificada empregando-se a técnica de eletroforese em gel de agarose. A extensão da lesão no DNA depende da acidez, concentração de S(IV), tempo de incubação e da presença de um segundo íon metálico. Usando a técnica de cromatografia líquida de alta eficiência (HPLC) foi possível estudar a oxidação de 2\'-deoxiguanosina a 8-oxo-7,8-dihidro-2\'-deoxiguanosina na presença dos oxidantes fortes gerados durante a autoxidação de S(IV) catalisada por Cu(II)/G4. Um estudo comparativo do efeito de vários íons metálicos evidenciou o sinergismo de Cu(II) e traços de um segundo íon metálico (Ni(II), Co(II) ou Mn(II), complexados ou não com tetraglicina). / The present work presents studies related to biomolecules damage (DNA and 2\'-deoxyguanosine) induced by Cu(III)/tetraglycine (Cu(III)/G4), oxysulfur radicals (SO3·-, SO4·-, SO5·-) and HSO5-, species generated during S(IV) autoxidation in the presence of Cu(II)/G4 or Cu(II) (absence of tetraglycine) and trace level of a second metal ion (Ni(II), Co(II) or Mn(II)). The formation of SO3·- and HO· radicals was detected by electronic paramagnetic resonance technique (EPR). Spectrophotometric and circular dichroism techniques were used to evaluate the Cu(III)/G4 formation in different experimental conditions, in the presence and the absence of S(IV), and the interaction of copper (II)/(III) complexes and DNA molecule. The effectiveness of Cu(III) formation depends on the acidity, S(IV) concentration, and buffers used. The damage on pUC 19 plasmid DNA was verified by agarose gel electrophoresis. The extent on the DNA damage was related to acidity, S(IV) concentration, incubation time and to the presence of a second metal ion. Using the high performance liquid chromatography technique (HPLC) it was possible to study the oxidation of 2\'-deoxyguanosine to 8-oxo-7,8-dihydro-2\'-deoxyguanosine in the presence of strong oxidants generated during the S(IV) autoxidation catalyzed by Cu(II)/G4. A comparative study of the effect of several metal ions showed the synergism of Cu(II) and traces of a second metal ion (Ni(II), Co(II) or Mn(II), as tetraglycine complexes or not).
6

Estudos de lesão ao DNA promovida pela autoxidação de S(IV) na presença de complexos de Cu(III)/tetraglicina. Efeito sinérgico de Ni(II), Co(II) e Mn(II) / Studies of DNA damage induced by sulfite autoxidation in the presence of Cu(II)/tetraglycine complexes. Effect synergistic of Ni(II), Co(II) and Mn(II).

Ruben Gregorio Moreno Moreno 09 December 2005 (has links)
O presente trabalho apresenta estudos de lesão em biomoléculas (DNA e 2\'-deoxiguanosina) induzida por Cu(III)/tetraglicina (Cu(III)/G4), radicais de óxidos de enxofre (SO3·-, SO4·-, SO5·-), HO· e HSO5-, espécies estas geradas durante a autoxidação de S(IV) na presença de Cu(II)/G4 ou Cu(II) (ausência de tetraglicina) e traços de um segundo íon metálico (Ni(II), Co(II) ou Mn(II)). A formação dos radicais SO3·- e HO· foi detectada pela técnica de ressonância paramagnética eletrônica (EPR). As técnicas de espectrofotometria e dicroísmo circular foram empregadas para avaliar a formação de Cu(III)/G4 em diferentes condições experimentais, na presença e ausência de S(IV), e a interação entre os complexos de cobre (II)/(III) e a molécula de DNA. A eficiência da formação de Cu(III) depende da acidez, concentração de S(IV) e dos tampões utilizados. A lesão no DNA plasmidial pUC19 foi verificada empregando-se a técnica de eletroforese em gel de agarose. A extensão da lesão no DNA depende da acidez, concentração de S(IV), tempo de incubação e da presença de um segundo íon metálico. Usando a técnica de cromatografia líquida de alta eficiência (HPLC) foi possível estudar a oxidação de 2\'-deoxiguanosina a 8-oxo-7,8-dihidro-2\'-deoxiguanosina na presença dos oxidantes fortes gerados durante a autoxidação de S(IV) catalisada por Cu(II)/G4. Um estudo comparativo do efeito de vários íons metálicos evidenciou o sinergismo de Cu(II) e traços de um segundo íon metálico (Ni(II), Co(II) ou Mn(II), complexados ou não com tetraglicina). / The present work presents studies related to biomolecules damage (DNA and 2\'-deoxyguanosine) induced by Cu(III)/tetraglycine (Cu(III)/G4), oxysulfur radicals (SO3·-, SO4·-, SO5·-) and HSO5-, species generated during S(IV) autoxidation in the presence of Cu(II)/G4 or Cu(II) (absence of tetraglycine) and trace level of a second metal ion (Ni(II), Co(II) or Mn(II)). The formation of SO3·- and HO· radicals was detected by electronic paramagnetic resonance technique (EPR). Spectrophotometric and circular dichroism techniques were used to evaluate the Cu(III)/G4 formation in different experimental conditions, in the presence and the absence of S(IV), and the interaction of copper (II)/(III) complexes and DNA molecule. The effectiveness of Cu(III) formation depends on the acidity, S(IV) concentration, and buffers used. The damage on pUC 19 plasmid DNA was verified by agarose gel electrophoresis. The extent on the DNA damage was related to acidity, S(IV) concentration, incubation time and to the presence of a second metal ion. Using the high performance liquid chromatography technique (HPLC) it was possible to study the oxidation of 2\'-deoxyguanosine to 8-oxo-7,8-dihydro-2\'-deoxyguanosine in the presence of strong oxidants generated during the S(IV) autoxidation catalyzed by Cu(II)/G4. A comparative study of the effect of several metal ions showed the synergism of Cu(II) and traces of a second metal ion (Ni(II), Co(II) or Mn(II), as tetraglycine complexes or not).

Page generated in 0.0515 seconds