Spelling suggestions: "subject:"bthermal conditioning"" "subject:"3thermal conditioning""
1 |
Estratégias para minimizar os efeitos de um ambiente térmico adverso para frangos de corte / Patrícia Martiniano de Oliveira. -Oliveira, Patrícia Martiniano de. January 2015 (has links)
Orientador:Marcelo Vasconcelos Meireles / Co-orientador:Max José de Araújo Faria Júnior / Co-orientador:Manoel Garcia Neto / Banca:Leda Gobbo de Freitas Bueno / Banca:Wilson Machado de Souza / Resumo:O calor limita a produção de frangos de corte. Este trabalho avaliou as interações entre termocondicionamento precoce (TCP) e o uso do equilíbrio eletrolítico (EE), sobre o desempenho e características da carcaça das aves. Assim, o balanço eletrolítico (BE = Na + K - Cl), foi ajustado em 350mEq/kg e a relação eletrolítica (K+Cl)/Na em 3:1, pelo programa PPFR. O experimento foi realizado no setor de Zootecnia da Faculdade de Medicina Veterinária de Araçatuba/UNESP. Alojaram-se 240 pintos machos de 1 dia de idade, linhagem Cobb-500®, em bateria metálica com 24 divisões e aquecimento elétrico automático. O delineamento experimental foi inteiramente ao acaso, em arranjo fatorial 2x2, totalizando 4 tratamentos com 6 repetições e 10 aves por parcela experimental. O TCP ocorreu no 5º dia de idade, por 24 horas a 36,5°C, em metade do lote. Posteriormente, as aves foram transferidas para um galpão climatizado e alojadas em boxes, da mesma forma que a outra parcela que não passou pelo TCP. Avaliaram-se os efeitos do estresse calórico crônico (6 horas a 32°C) aplicado do 35º ao 39º dia de idade. Foram monitorados a temperatura e umidade do ar, bem como a temperatura de globo negro. Alimentação e água foram fornecidas ad libitum. Calcularam-se os dados de desempenho zootécnico e a taxa de mortalidade das aves. Submeteram-se os resultados à análise de variância e comparação de médias pelo teste de Tukey. Não houve interação entre o TCP e o EE sobre o desempenho e características da carcaça das aves. As estratégias, TCP e EE mostraram-se ineficazes a fim de amenizar os efeitos do estresse calórico crônico em frangos de corte / Abstract:The heat limits the production of broilers. This study evaluated the interactions between early thermal conditioning (ETC) and the electrolyte balance (EB) on performance and characteristics of birds' carcass. Thus, the electrolyte balance (BE = Na+ + K+ - Cl- ), was set to 350mEq/kg and electrolyte ratio (K+ + Cl- )/ Na+ in 3:1 by PPFR program. The experiment was carried out at the Animal Science department of the Faculty of Veterinary Medicine of Araçatuba / UNESP. It was used 240 male chicks of 1 day old, Cobb-500®, lodged in metal batteries with 24 divisions and automatic electric heating. The experimental design was completely randomized in a factorial arrangement 2x2, totaling 4 treatments with 6 replicates and 10 birds per experimental plot. ETC occurred on the 5th day of age for 24 hours at 36.5 °C in half of the batch. Subsequently, these birds were transferred to an environmentally controlled shed and were grown in boxes, in the same way as the other half that not received ETC treatment. The effects of chronic heat stress (6 hours at 32 °C) applied from the 35th through the 39th day of age were evaluated. Temperature and air humidity, as well black-globe temperature were monitored electronically. Food and water were provided ad libitum. The growth performance data and the mortality rate of birds were measured. The results were subjected to analysis of variance and comparison of means was done by Tukey test. There were no interaction effects between ETC and EB on performance and characteristics of birds' carcass. The strategies ETC and EB proved to be ineffective in order to mitigate the effects of chronic heat stress in broilers / Mestre
|
2 |
Estratégias para minimizar os efeitos de um ambiente térmico adverso para frangos de corte: Patrícia Martiniano de Oliveira. -Oliveira, Patrícia Martiniano de [UNESP] 06 August 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:20Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-08-06. Added 1 bitstream(s) on 2016-06-07T17:16:58Z : No. of bitstreams: 1
000864744.pdf: 2407312 bytes, checksum: 10fe8efab5b26398740fcfe1df7ac526 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / The heat limits the production of broilers. This study evaluated the interactions between early thermal conditioning (ETC) and the electrolyte balance (EB) on performance and characteristics of birds' carcass. Thus, the electrolyte balance (BE = Na+ + K+ - Cl- ), was set to 350mEq/kg and electrolyte ratio (K+ + Cl- )/ Na+ in 3:1 by PPFR program. The experiment was carried out at the Animal Science department of the Faculty of Veterinary Medicine of Araçatuba / UNESP. It was used 240 male chicks of 1 day old, Cobb-500®, lodged in metal batteries with 24 divisions and automatic electric heating. The experimental design was completely randomized in a factorial arrangement 2x2, totaling 4 treatments with 6 replicates and 10 birds per experimental plot. ETC occurred on the 5th day of age for 24 hours at 36.5 °C in half of the batch. Subsequently, these birds were transferred to an environmentally controlled shed and were grown in boxes, in the same way as the other half that not received ETC treatment. The effects of chronic heat stress (6 hours at 32 °C) applied from the 35th through the 39th day of age were evaluated. Temperature and air humidity, as well black-globe temperature were monitored electronically. Food and water were provided ad libitum. The growth performance data and the mortality rate of birds were measured. The results were subjected to analysis of variance and comparison of means was done by Tukey test. There were no interaction effects between ETC and EB on performance and characteristics of birds' carcass. The strategies ETC and EB proved to be ineffective in order to mitigate the effects of chronic heat stress in broilers
|
3 |
Viabilidade técnica e econômica do condicionamento geotérmico de edificações no Rio Grande do Sul / Technical and economic feasibility of geothermal conditioning of buildings in Rio Grande do SulBarcelos, Roberto Hubner January 2018 (has links)
O elevado consumo energético de edificações para o seu condicionamento térmico já é um dos maiores impactos ambientais da construção civil nos países desenvolvidos e, progressivamente, vem se tornando uma preocupação também nos países em desenvolvimento. Uma alternativa renovável relativamente recente, tanto para aquecimento como para resfriamento, são as bombas de calor geotérmicas (ground source heat pumps, GSHPs), que se valem da inércia térmica do solo para reduzir significativamente a demanda energética em relação ao ar. Apesar do seu grande potencial em reduzir o consumo de energia e as emissões de carbono, esta tecnologia ainda é quase inexistente na América Latina, não somente devido à falta de conhecimento ao seu respeito, mas também pela incerteza quanto à sua viabilidade frente a um custo inicial mais elevado. Embora existam muitas pesquisas sobre o funcionamento de GSHPs, grande parte do conhecimento prático quanto ao projeto, desempenho e viabilidade é baseada na experiência dos primeiros países onde a tecnologia começou a se tornar popular, e não pode ser assumida automaticamente como válida em outras situações sem uma avaliação prévia Estudos anteriores apontaram que o retorno econômico de GSHPs tende a ser maior em climas mais frios, enquanto a eficiência tende a ser maior em climas mais amenos, mas com sazonalidade. Por apresentar um bom balanço destas características, o Estado do Rio Grande do Sul apresenta potencial para um desempenho elevado de GSHPs. O objetivo deste trabalho é estimar os níveis de eficiência que esta tecnologia pode atingir em uma cidade de referência no Estado, assim como seu retorno econômico frente a ASHPs (air source heat pumps, ou seja, aparelhos de ar condicionado, ou A/C), seus limitantes e as dificuldades de projeto. Uma edificação unifamiliar residencial em Porto Alegre, projetada especialmente para estudos de sustentabilidade, foi utilizada como caso de estudo para o projeto conceitual completo de um GSHP vertical, um GSHP horizontal e um ASHP. Foram estimadas a demanda de energia e os custos de operação e de implantação para determinadas condições, que foram comparadas em um estudo de viabilidade econômica. Após, os resultados foram extrapolados por uma análise de sensitividade para condições mais genéricas de consumo. Através dos cálculos, observou-se que a tecnologia de GSHPs atingiu o dobro da eficiência dos A/C mais eficientes disponíveis para o caso de estudo. Economicamente, a tecnologia também se mostrou viável, e foram estimados limitantes econômicos a esta viabilidade. Por fim, o processo de projeto desenvolvido pode servir de auxílio a novos projetistas na área. / The high energy consumption in buildings for their thermal conditioning is already one of the greatest environmental impacts of civil construction in developed countries and, progressively, is also becoming a concern in the developing countries. A relatively recent renewable alternative, as much for heating as for cooling, are the ground source heat pumps, GSHPs, which take advantage of the thermal inertia of the ground to significantly decrease the energy demand comparing to air as a source. In spite of their huge potential for decreasing energy comsumption and carbon emissions, this technology is still almost inexistent in Latin America, due not only to lack of awareness, but mainly to uncertainties about their feasibility because of their higher investment cost. Although there are many researches about the characteristics and operation of GSHPs, great part of the practical knowledge as to the design, performance and feasibility is based in the experience from the first countries where the technology spreaded, and cannot be automatically assumed as valid without a previous evaluation. Former studies indicated that the economic profit of GSHPs tends to be higher in colder climates, while the efficiency tends to be higher in milder, but still seasonal climates. For presenting a good balance among these factors, the Rio Grande do Sul State shows potential for a high performance of GSHPs The objective of this work is to estimate the efficiency levels that can be reached by this technology in a reference city in the State, as its financial feedback compared to ASHPs (air source heat pumps, the traditional air conditioners, or A/C), its limitations and the design difficulties. A residential single-family building in Porto Alegre, specifically designed for sustainability studies, was used as case study for the complete conceptual design of a vertical GSHP, a horizontal GSHP and an ASHP. The energy demand and operation and installation costs for specific conditions were estimated and compared in a economic feasibility study. After, the results were extrapolated through a sensitivity analysis for more generic situations of consumption. Through the calculations, it was observed that the technology achieved twice the efficiency of the most efficient A/C available for the case study. Economically, the technology showed itself viable, and economic limitations were also estimated. At last, the developed design process can also serve as aid to new designers in the field.
|
4 |
Viabilidade técnica e econômica do condicionamento geotérmico de edificações no Rio Grande do Sul / Technical and economic feasibility of geothermal conditioning of buildings in Rio Grande do SulBarcelos, Roberto Hubner January 2018 (has links)
O elevado consumo energético de edificações para o seu condicionamento térmico já é um dos maiores impactos ambientais da construção civil nos países desenvolvidos e, progressivamente, vem se tornando uma preocupação também nos países em desenvolvimento. Uma alternativa renovável relativamente recente, tanto para aquecimento como para resfriamento, são as bombas de calor geotérmicas (ground source heat pumps, GSHPs), que se valem da inércia térmica do solo para reduzir significativamente a demanda energética em relação ao ar. Apesar do seu grande potencial em reduzir o consumo de energia e as emissões de carbono, esta tecnologia ainda é quase inexistente na América Latina, não somente devido à falta de conhecimento ao seu respeito, mas também pela incerteza quanto à sua viabilidade frente a um custo inicial mais elevado. Embora existam muitas pesquisas sobre o funcionamento de GSHPs, grande parte do conhecimento prático quanto ao projeto, desempenho e viabilidade é baseada na experiência dos primeiros países onde a tecnologia começou a se tornar popular, e não pode ser assumida automaticamente como válida em outras situações sem uma avaliação prévia Estudos anteriores apontaram que o retorno econômico de GSHPs tende a ser maior em climas mais frios, enquanto a eficiência tende a ser maior em climas mais amenos, mas com sazonalidade. Por apresentar um bom balanço destas características, o Estado do Rio Grande do Sul apresenta potencial para um desempenho elevado de GSHPs. O objetivo deste trabalho é estimar os níveis de eficiência que esta tecnologia pode atingir em uma cidade de referência no Estado, assim como seu retorno econômico frente a ASHPs (air source heat pumps, ou seja, aparelhos de ar condicionado, ou A/C), seus limitantes e as dificuldades de projeto. Uma edificação unifamiliar residencial em Porto Alegre, projetada especialmente para estudos de sustentabilidade, foi utilizada como caso de estudo para o projeto conceitual completo de um GSHP vertical, um GSHP horizontal e um ASHP. Foram estimadas a demanda de energia e os custos de operação e de implantação para determinadas condições, que foram comparadas em um estudo de viabilidade econômica. Após, os resultados foram extrapolados por uma análise de sensitividade para condições mais genéricas de consumo. Através dos cálculos, observou-se que a tecnologia de GSHPs atingiu o dobro da eficiência dos A/C mais eficientes disponíveis para o caso de estudo. Economicamente, a tecnologia também se mostrou viável, e foram estimados limitantes econômicos a esta viabilidade. Por fim, o processo de projeto desenvolvido pode servir de auxílio a novos projetistas na área. / The high energy consumption in buildings for their thermal conditioning is already one of the greatest environmental impacts of civil construction in developed countries and, progressively, is also becoming a concern in the developing countries. A relatively recent renewable alternative, as much for heating as for cooling, are the ground source heat pumps, GSHPs, which take advantage of the thermal inertia of the ground to significantly decrease the energy demand comparing to air as a source. In spite of their huge potential for decreasing energy comsumption and carbon emissions, this technology is still almost inexistent in Latin America, due not only to lack of awareness, but mainly to uncertainties about their feasibility because of their higher investment cost. Although there are many researches about the characteristics and operation of GSHPs, great part of the practical knowledge as to the design, performance and feasibility is based in the experience from the first countries where the technology spreaded, and cannot be automatically assumed as valid without a previous evaluation. Former studies indicated that the economic profit of GSHPs tends to be higher in colder climates, while the efficiency tends to be higher in milder, but still seasonal climates. For presenting a good balance among these factors, the Rio Grande do Sul State shows potential for a high performance of GSHPs The objective of this work is to estimate the efficiency levels that can be reached by this technology in a reference city in the State, as its financial feedback compared to ASHPs (air source heat pumps, the traditional air conditioners, or A/C), its limitations and the design difficulties. A residential single-family building in Porto Alegre, specifically designed for sustainability studies, was used as case study for the complete conceptual design of a vertical GSHP, a horizontal GSHP and an ASHP. The energy demand and operation and installation costs for specific conditions were estimated and compared in a economic feasibility study. After, the results were extrapolated through a sensitivity analysis for more generic situations of consumption. Through the calculations, it was observed that the technology achieved twice the efficiency of the most efficient A/C available for the case study. Economically, the technology showed itself viable, and economic limitations were also estimated. At last, the developed design process can also serve as aid to new designers in the field.
|
5 |
Viabilidade técnica e econômica do condicionamento geotérmico de edificações no Rio Grande do Sul / Technical and economic feasibility of geothermal conditioning of buildings in Rio Grande do SulBarcelos, Roberto Hubner January 2018 (has links)
O elevado consumo energético de edificações para o seu condicionamento térmico já é um dos maiores impactos ambientais da construção civil nos países desenvolvidos e, progressivamente, vem se tornando uma preocupação também nos países em desenvolvimento. Uma alternativa renovável relativamente recente, tanto para aquecimento como para resfriamento, são as bombas de calor geotérmicas (ground source heat pumps, GSHPs), que se valem da inércia térmica do solo para reduzir significativamente a demanda energética em relação ao ar. Apesar do seu grande potencial em reduzir o consumo de energia e as emissões de carbono, esta tecnologia ainda é quase inexistente na América Latina, não somente devido à falta de conhecimento ao seu respeito, mas também pela incerteza quanto à sua viabilidade frente a um custo inicial mais elevado. Embora existam muitas pesquisas sobre o funcionamento de GSHPs, grande parte do conhecimento prático quanto ao projeto, desempenho e viabilidade é baseada na experiência dos primeiros países onde a tecnologia começou a se tornar popular, e não pode ser assumida automaticamente como válida em outras situações sem uma avaliação prévia Estudos anteriores apontaram que o retorno econômico de GSHPs tende a ser maior em climas mais frios, enquanto a eficiência tende a ser maior em climas mais amenos, mas com sazonalidade. Por apresentar um bom balanço destas características, o Estado do Rio Grande do Sul apresenta potencial para um desempenho elevado de GSHPs. O objetivo deste trabalho é estimar os níveis de eficiência que esta tecnologia pode atingir em uma cidade de referência no Estado, assim como seu retorno econômico frente a ASHPs (air source heat pumps, ou seja, aparelhos de ar condicionado, ou A/C), seus limitantes e as dificuldades de projeto. Uma edificação unifamiliar residencial em Porto Alegre, projetada especialmente para estudos de sustentabilidade, foi utilizada como caso de estudo para o projeto conceitual completo de um GSHP vertical, um GSHP horizontal e um ASHP. Foram estimadas a demanda de energia e os custos de operação e de implantação para determinadas condições, que foram comparadas em um estudo de viabilidade econômica. Após, os resultados foram extrapolados por uma análise de sensitividade para condições mais genéricas de consumo. Através dos cálculos, observou-se que a tecnologia de GSHPs atingiu o dobro da eficiência dos A/C mais eficientes disponíveis para o caso de estudo. Economicamente, a tecnologia também se mostrou viável, e foram estimados limitantes econômicos a esta viabilidade. Por fim, o processo de projeto desenvolvido pode servir de auxílio a novos projetistas na área. / The high energy consumption in buildings for their thermal conditioning is already one of the greatest environmental impacts of civil construction in developed countries and, progressively, is also becoming a concern in the developing countries. A relatively recent renewable alternative, as much for heating as for cooling, are the ground source heat pumps, GSHPs, which take advantage of the thermal inertia of the ground to significantly decrease the energy demand comparing to air as a source. In spite of their huge potential for decreasing energy comsumption and carbon emissions, this technology is still almost inexistent in Latin America, due not only to lack of awareness, but mainly to uncertainties about their feasibility because of their higher investment cost. Although there are many researches about the characteristics and operation of GSHPs, great part of the practical knowledge as to the design, performance and feasibility is based in the experience from the first countries where the technology spreaded, and cannot be automatically assumed as valid without a previous evaluation. Former studies indicated that the economic profit of GSHPs tends to be higher in colder climates, while the efficiency tends to be higher in milder, but still seasonal climates. For presenting a good balance among these factors, the Rio Grande do Sul State shows potential for a high performance of GSHPs The objective of this work is to estimate the efficiency levels that can be reached by this technology in a reference city in the State, as its financial feedback compared to ASHPs (air source heat pumps, the traditional air conditioners, or A/C), its limitations and the design difficulties. A residential single-family building in Porto Alegre, specifically designed for sustainability studies, was used as case study for the complete conceptual design of a vertical GSHP, a horizontal GSHP and an ASHP. The energy demand and operation and installation costs for specific conditions were estimated and compared in a economic feasibility study. After, the results were extrapolated through a sensitivity analysis for more generic situations of consumption. Through the calculations, it was observed that the technology achieved twice the efficiency of the most efficient A/C available for the case study. Economically, the technology showed itself viable, and economic limitations were also estimated. At last, the developed design process can also serve as aid to new designers in the field.
|
6 |
Energy Consumption of Thermal Conditioning System for Heavy-duty Electric Vehicles / Energiförbrukning av termiskt konditioneringssystem för tunga elfordonHe, Haohao January 2021 (has links)
The deployment of electric vehicles has speeded up during the past ten years. As heavy-duty trucks are a significant source of GHG emissions, electrification is an encouraging way to lead to sustainability beyond doubt. However, some constraints regarding electric vehicles have emerged. Range extension is a primary challenge of the development of electric vehicles, where thermal conditioning systems can have a considerable impact. Some researches have been done on electric passenger vehicles. However, studies regarding the energy consumption for the thermal conditioning system of heavy-duty electric vehicles are scarcely provided.This study therefore focuses on estimating the energy consumption for the auxiliary heating/cooling and studying the influence of the ambient temperature, vehicle velocity, payload, and driving cycles. A designed integrated thermal conditioning system model was constructed in GT-SUITE, with three subsystems to provide thermal comfort for the truck cabin, meet the operative temperature for battery packs and condition the power electronics and the electric machine. Calibrations were done and yielded acceptable relative errors less than 10%, regarding the cabin and battery heaters.The study shows that the thermal conditioning system consumes the most energy during extremely cold weather, reaching up to 10 kW when the ambient temperature is lower than -20℃. Moreover, the energy consumption during heating/cooling will increase if the vehicle velocity increases. However, it remains stable during mild weather. Payload has different impacts on the energy consumption for heating and cooling. As higher payload results in higher waste heat from the electric machine and batteries, it alleviates the heating while burdens the cooling. Four different driving cycles were simulated, and the result reveals that despite the cycle with the lowest average speed has the highest energy consumption/km, however has the lowest average power.
|
7 |
Verificação dos valores dos coeficientes de convecção do ar no exterior de edifícios no estado da ParaíbaPorto, Eduardo Figueiredo 05 March 2007 (has links)
Submitted by Viviane Lima da Cunha (viviane@biblioteca.ufpb.br) on 2017-07-18T13:27:53Z
No. of bitstreams: 1
arquivototal.pdf: 2894407 bytes, checksum: 993603497277207e108988a17bd6d3b2 (MD5) / Made available in DSpace on 2017-07-18T13:27:53Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 2894407 bytes, checksum: 993603497277207e108988a17bd6d3b2 (MD5)
Previous issue date: 2007-03-05 / This research investigated and analysed the characteristics and peculiarities of wind flowing
that take place in the state of Paraiba in order to verify the local values for the air coefficients
of external convection (hc’s), based in non-dimensional numbers like Prandlt, Reynolds and
Nusselt, and empirical correlations as suggested by Hilpert. These correlations are widely
used and the results demonstrate that the verified values significantly differ from the ones
currently recommended by the Brazilian norms concerning the thermal performance of
buildings and the basic parameters of projects for central air-conditioners. The results
highlighted the need to review these coefficients and take into consideration the
interrelationship between the standards of local ventilation and construction regulations when
calculating the thermal conditioning of buildings in order to minimize environmental impact
and improve energy performance of buildings, which will reduce costs. / Este trabalho investigou e analisou as características e as condições de escoamento dos ventos
que ocorrem no estado da Paraíba, a fim de determinar valores locais para os coeficientes de
convecção do ar externo (hc’s), com base nos números adimensionais de Prandlt, Reynolds e
Nusselt, e correlações empíricas com as sugeridas por Hilpert, que são largamente utilizadas,
cujos resultados demonstraram que os valores verificados diferem significativamente dos
valores atualmente recomendados palas Normas Brasileiras referentes ao desempenho térmico
de edificações, e aos parâmetros básicos de projeto de centrais de ar-condicionado,
conduzindo à necessidade de se reverem tais coeficientes e considerarem as inter-relações
entre o padrão de ventilação local e o de ocupação do solo, quando do cálculo de
acondicionamento térmico de edifícios, para se minimizar os impactos ambientais, otimizar o
desempenho energético de edificações, aumentando a economia de energia reduzindo custos.
|
8 |
Mapeamento e análise espacial do ambiente térmico de aviários de postura abertos em sistemas verticais / Mapping and spatial analysis of the thermal environment of open laying hens housing in vertical systemCoelho, Diogo José de Rezende 21 February 2014 (has links)
Made available in DSpace on 2015-03-26T13:24:00Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1723171 bytes, checksum: 7eb23327b84ea3efaee3e770c680bcc8 (MD5)
Previous issue date: 2014-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the current poultry industry, advances in the areas of nutrition, genetics, management and animal health, along with the importance now being given to the ambiance of the bird to its range of thermal comfort, the activity is allowed to consolidate as one of the most important agricultural sector. The production environment does a fundamental role in the success or failure of the activity, and environmental factors such as temperature and relative humidity are those that most directly affect the birds, because compromise their most important baseline function, which is to maintain of homeothermic own. Thus, the birds require values of temperature and relative humidity of the environmental air within certain specific ranges, and out of this comfort zone, have compromised their performance. The objective of this work was to realize the full thermal mapping of typical barns for layers practiced in Brazil, vertical rearing systems, and to establish the most representative spatial position of the average conditions of temperature and relative humidity of the air inside the housing for better positioning the sensors command of air conditioners panels. The study was conducted in Itanhandu, in Minas Gerais State - Brazil, in a commercial laying hens barn, with the typical patterns used barn creation practiced in Brazil, called vertical systems, during the peak egg production. The barn is 100% automated, having 100,000 birds / barn, housed in four batteries with six levels of cages. The results were presented in two articles: Article I - Mapping the thermal environment of open aviaries in vertical position for the phase of peak egg production system; Article II - Determination of representative spatial position of the average temperature and relative humidity for layer hens in vertical rearing systems. Through the results of the survey, one can observe a thermal variability within the aviary, with the central region had higher temperatures of the extremities, and in situations of maximum temperatures occurrence of heat stress in birds. It was also possible to determine the best allocation for spatial positioning of the temperature sensors and humidity within the facility, and that they represent the internal thermal conditions are distant extremities of the aviary at 1⁄4 the length of the installation, and also away from the sides of barn, so as to be positioned in the intermediate runners, the average height of the battery cages. / Na avicultura atual, os avanços nas áreas da nutrição, genética, manejo e sanidade animal, juntamente com a importância que passou a ser dada à ambientação da ave à sua faixa de conforto térmico, permitiram que a atividade se consolidasse como uma das mais importantes do setor agropecuário. O ambiente de produção desempenha papel fundamental para o sucesso ou fracasso da atividade, sendo que fatores ambientais tais como, temperatura e umidade relativa do ar são os que afetam mais diretamente as aves, pois comprometem a sua função basal mais importante, que é a manutenção da própria homeotermia. Sendo assim, as aves necessitam de valores de temperatura e umidade relativa do ar ambiente dentro de certas faixas específicas e, fora desta zona de conforto, tem seu desempenho comprometido. Objetivou-se com este trabalho realizar o mapeamento térmico completo de aviário de postura típico dos padrões praticados no Brasil, sistemas verticais de criação, bem como estabelecer a posição espacial mais representativa das condições médias de temperatura e umidade relativa do ar interna do alojamento para melhor posicionamento dos sensores de comando dos painéis climatizadores. O trabalho foi desenvolvido no município de Itanhandu - Minas Gerais, em uma granja comercial de aves de postura, sendo o aviário utilizado típico dos padrões de criação praticados no Brasil, denominados sistemas verticais, durante a fase de pico de postura das aves. O aviário é 100% automatizado, possuindo 100.000 aves/aviário, alojadas em quatro baterias com seis andares de gaiolas. Os resultados obtidos foram apresentados em dois artigos: Artigo I - Mapeamento do ambiente térmico de aviários de postura abertos em sistema vertical para a fase de pico de postura das aves; Artigo II - Determinação da posição espacial representativa das condições médias de temperatura e umidade relativa do ar para aviários de postura em sistemas verticais de criação. Por meio dos resultados da pesquisa realizada, pode-se observar uma variabilidade térmica dentro do aviário, com a região central apresentando temperaturas superiores as das extremidades, e nas situações de temperaturas máximas ocorrência de estresse calórico das aves. Foi possível também determinar que os melhores posicionamentos espaciais para alocação dos sensores de temperatura e umidade dentro da instalação, e que estes representassem as condições térmicas internas, são distantes das extremidades do aviário, à 1⁄4 o comprimento da instalação, e também afastadas das laterais do aviário, de modo a ser posicionado nos corredores intermediários, na altura média da bateria de gaiolas.
|
9 |
Respostas de frangos de corte ao estresse térmico agudo ou crônico / Responses of broilers exposed to acute or chronic heat stressSandre, Danilo Gualberto de [UNESP] 03 June 2016 (has links)
Submitted by DANILO GUALBERTO DE SANDRE null (danilo.sandre@hotmail.com) on 2016-07-14T21:57:39Z
No. of bitstreams: 1
TESE e ARTIGO Danilo18.pdf: 1530531 bytes, checksum: 1a9072d60b1aee7abd7f4a51ea079af4 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-18T20:35:09Z (GMT) No. of bitstreams: 1
sandre_dg_me_araca.pdf: 1530531 bytes, checksum: 1a9072d60b1aee7abd7f4a51ea079af4 (MD5) / Made available in DSpace on 2016-07-18T20:35:09Z (GMT). No. of bitstreams: 1
sandre_dg_me_araca.pdf: 1530531 bytes, checksum: 1a9072d60b1aee7abd7f4a51ea079af4 (MD5)
Previous issue date: 2016-06-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dois experimentos envolvendo 1280 pintos machos Cobb 500, foram conduzidos para avaliar as possíveis interações entre condicionamento termo precoce e balanço eletrolítico da dieta sobre o desempenho de frangos de corte, bem como estudar os efeitos do estresse térmico agudo e crônico. No d 8, as aves foram transferidas para 32 boxes, com raspas de madeira e resíduo desidratado de acerola (proporção ½ a ½ ) como cama, mantendo os mesmos tratamentos com oito repetições cada. Os dados da Exp. 1 (stress agudo) e 2 (stress crónico) foram combinados num arranjo fatorial 2x2x2 (com e sem condicionamento térmico precoce (CTP); dieta com e sem equilíbrio eletrolítico (EE); e estresse térmico agudo ou crônico. A dieta com EE foi calculada como mEq / kg para a Na + K-Cl e o valor da relação (K + Cl) / Na, com 300 mEq / kg e uma proporção de 3: 1, respectivamente. As aves foram alimentadas com: (1) uma dieta tradicional (176 mEq / kg e a relação de 3,36: 1) sem CTP; (2) dieta tradicional com CTP; (3) dieta com EE e sem CTP e (4) dieta com EE e CTP. Ração e água foram fornecidas ad libitum. Metade das aves foram expostas a 36 °C durante 24 horas com a idade de 5, enquanto que a outra metade não foi exposto a CTP. Na idade de 38 d, metade dos pintos foram termicamente desafiados por estresse térmico agudo de 36 °C durante 6h e com a idade de 35 a 39 d, outra metade dos pintos foram termicamente desafiado por um estresse térmico crônico de 32 °C por 6h. O consumo de ração, peso corporal (PC), a umidade das fezes e deposição de gordura abdominal foram determinadas a 46 d de idade e taxa de conversão alimentar ajustado foi calculado através da inclusão de PC da mortalidade. Coordenadas tricromáticas (L*, a*, e b*) foram medidos no músculo do peito, às 24h. Nenhum efeito de interação foi encontrado com nenhum dos parâmetros avaliados. Assim, não existe sinergismo para qualquer um dos traços. Houve aumento expressivo da mortalidade [(3,06-65,62%) / P <0,0001] de estresse agudo. O EE aumentou a umidade nas fezes (P = 0,0202). Os conteúdos de lipídios dos tecidos abdominais foram afetados pela exposição ao calor e diminuiu significativamente (P <0,0001) para crônica (53.9g) versus estresse agudo (127.5g). Além disso, um efeito significativo (P <0,0001) valores mais elevados foi encontrado em carne para aguda (66,4 e 23,2) versus o estresse crônico (57,6 e 17,6), em L* e b*, respectivamente. Os resultados sugerem que as aves submetidas a estresse agudo estão sujeitos a síndrome do músculo pálida aves. / Two experiments involving 1280 male Cobb 500 chicks were conducted to evaluate the possible interactions between early thermal conditioning and electrolyte balance of the diet on the performance of broiler chickens, as well as studying the effects of acute and chronic heat stress. On d 8, the broilers were transferred to 32 floor pens with wood shavings as litter while maintaining the same treatments with eight replicates each. The data from Exp. 1 (acute stress) and 2 (chronic stress) were combined in a 2x2x2 factorial arrangement [with and without early thermal conditioning (ETC)]; diet with and without electrolyte balance (EB); and acute or chronic heat stress. The diet with EB was calculated as mEq/kg for Na+K-Cl and the value the ratio (K+Cl)/Na, with 300 mEq/kg and a ratio the 3:1, respectively. The birds were fed: (1) a traditional diet (176 mEq/kg and a ratio the 3.36:1) without ETC; (2) traditional diet with ETC; (3) diet with EB and without ETC and (4) diet with EB and ETC. Feed and water were supplied ad libitum. Half of birds were exposed to 36°C for 24h at the age of 5, whereas the remaining half was not exposed to ETC. At the age of 38 d, half chicks were thermally challenged by an acute heat stress of 36°C for 6h or at the age of 35 to 39 d, another half chicks were thermally challenged by a chronic heat stress of 32°C for 6h. Feed intake, body weight (BW), moisture of feces and abdominal fat deposition were determined at 46 d of age and adjusted feed conversion ratio was calculated by including BW of mortality. Trichromatic coordinates (L*, a*, and b*) were measured on the breast muscle at 24h. No interaction effects were found for any of the parameters evaluated. Thus, there is no synergism for any of the traits. There was expressive increase of mortality [(3.06 to 65.62%) / P<0.0001] from acute stress. The EB increased moisture of feces (P=0.0202). Lipid contents of abdominal tissues was affected by heat exposure with significantly decreased (P<0.0001) to chronic (53.9g) versus acute stress (127.5g). Also, a significant effect (P<0.0001) values higher was found in meat for acute (66.4 and 23.2) versus chronic stress (57.6 and 17.6) on L* and b*, respectively. The results suggest that birds submitted to acute stress are subject to pale poultry muscle syndrome.
|
10 |
Respostas de frangos de corte ao estresse térmico agudo ou crônico /Sandre, Danilo Gualberto de. January 2016 (has links)
Orientador: Guilherme de Paula Nogueira / Cooientador: Garcia Neto, Manoel / Banca: Marcelo Vasconcelos Meireles / Banca: Antonio Celso Pezzato / Resumo: Dois experimentos envolvendo 1280 pintos machos Cobb 500, foram conduzidos para avaliar as possíveis interações entre condicionamento termo precoce e balanço eletrolítico da dieta sobre o desempenho de frangos de corte, bem como estudar os efeitos do estresse térmico agudo e crônico. No d 8, as aves foram transferidas para 32 boxes, com raspas de madeira e resíduo desidratado de acerola (proporção ½ a ½ ) como cama, mantendo os mesmos tratamentos com oito repetições cada. Os dados da Exp. 1 (stress agudo) e 2 (stress crónico) foram combinados num arranjo fatorial 2x2x2 (com e sem condicionamento térmico precoce (CTP); dieta com e sem equilíbrio eletrolítico (EE); e estresse térmico agudo ou crônico. A dieta com EE foi calculada como mEq / kg para a Na + K-Cl e o valor da relação (K + Cl) / Na, com 300 mEq / kg e uma proporção de 3: 1, respectivamente. As aves foram alimentadas com: (1) uma dieta tradicional (176 mEq / kg e a relação de 3,36: 1) sem CTP; (2) dieta tradicional com CTP; (3) dieta com EE e sem CTP e (4) dieta com EE e CTP. Ração e água foram fornecidas ad libitum. Metade das aves foram expostas a 36 °C durante 24 horas com a idade de 5, enquanto que a outra metade não foi exposto a CTP. Na idade de 38 d, metade dos pintos foram termicamente desafiados por estresse térmico agudo de 36 °C durante 6h e com a idade de 35 a 39 d, outra metade dos pintos foram termicamente desafiado por um estresse térmico crônico de 32 °C por 6h. O consumo de ração, peso corporal (PC)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Two experiments involving 1280 male Cobb 500 chicks were conducted to evaluate the possible interactions between early thermal conditioning and electrolyte balance of the diet on the performance of broiler chickens, as well as studying the effects of acute and chronic heat stress. On d 8, the broilers were transferred to 32 floor pens with wood shavings as litter while maintaining the same treatments with eight replicates each. The data from Exp. 1 (acute stress) and 2 (chronic stress) were combined in a 2x2x2 factorial arrangement [with and without early thermal conditioning (ETC)]; diet with and without electrolyte balance (EB); and acute or chronic heat stress. The diet with EB was calculated as mEq/kg for Na+K-Cl and the value the ratio (K+Cl)/Na, with 300 mEq/kg and a ratio the 3:1, respectively. The birds were fed: (1) a traditional diet (176 mEq/kg and a ratio the 3.36:1) without ETC; (2) traditional diet with ETC; (3) diet with EB and without ETC and (4) diet with EB and ETC. Feed and water were supplied ad libitum. Half of birds were exposed to 36°C for 24h at the age of 5, whereas the remaining half was not exposed to ETC. At the age of 38 d, half chicks were thermally challenged by an acute heat stress of 36°C for 6h or at the age of 35 to 39 d, another half chicks were thermally challenged by a chronic heat stress of 32°C for 6h. Feed intake, body weight (BW), moisture of feces and abdominal fat deposition were determined at 46 d of age and adjusted feed conversio... (Complete abstract click electronic access below) / Mestre
|
Page generated in 0.1465 seconds