1

Nanoscale Thermal Transport at Graphene-Soft Material Interfaces

Liu, Ying 05 July 2016 (has links)
Nanocomposites consist of graphene dispersed in matrices of soft materials are promising thermal management materials. A fundamental understanding of the thermal transport at graphene-soft material interfaces is essential for developing these nanocomposites. In this dissertation, thermal transport at graphene-octane interfaces was investigated using molecular dynamics simulations, and the results revealed several important characteristics of such thermal transport. The interfacial thermal conductance of graphene-octane interfaces were studied first. It was found that the interfacial thermal conductance exhibits a distinct duality: if heat enters graphene from one side of its basal plane and leaves it through the other side, the corresponding interfacial thermal conductance, Gacross, is large; if heat enters graphene from both sides of its basal plane and leaves it at a position far away on its basal plane, the corresponding interfacial thermal conductance, Gnon-across, is small. Gacross is ~30 times larger than Gnon-across for a single-layer graphene immersed in liquid octane. Additional analysis showed that this duality originates partially from the strong, positive correlations between the heat fluxes at the two surfaces of a graphene layer. The interfacial thermal conductance of the graphene-soft material interfaces in presence of defects in the graphene was then studied. The results showed that the heat transfer at the interfaces is enhanced by defects. Estimations based on effective medium theories showed that the effective thermal conductivity of the graphene-based composites could even be enhanced with defects in graphene when heat transfer at the graphene-soft material interface is the bottleneck for the thermal transport in these composites. To describe the interfacial thermal transport at graphene interfaces uniformly, a nonlocal constitutive model was proposed and validated to replace the classical Kapitza model. By characterizing the thermal transport properties of graphene interfaces using a pair of thermal conductance, the model affords a uniform description of the thermal transport at graphene interfaces for different thermal transport modes. Using this model, the data interpretation in time domain thermalreflectance (TDTR) measurements was investigated, and the results showed that the interfacial thermal conductance measured in typical TDTR tests is that of the across mode for thin-layered materials. / Ph. D.
2

Matériaux d'Interface Thermique Nanostructurés / Thermal Interface Materials Nanostructured

Daon, Joffrey 06 December 2016 (has links)
Dans le domaine de la microélectronique de puissance, les progrès de miniaturisation ne cessent de s’accroître. En effet, le nombre de composants par unité de surface a suivie durant de nombreuses années la loi de Moore. Cette évolution implique une augmentation de la densité d’énergie à évacuer sous forme de chaleur, ce qui rend le contrôle de la température de fonctionnement difficile et a pour effet de diminuer la fiabilité des systèmes électroniques.C’est pourquoi, le management thermique des matériaux d’interface thermique est indispensable pour pérenniser le bon fonctionnement des dispositifs de puissance dans leur environnement. L’utilité de ces matériaux est d’améliorer l’évacuation de la chaleur des composants électroniques vers le milieu environnant via un dissipateur thermique (radiateur, fluide caloporteur). Pour tenter de répondre à ces besoins, ce sujet de thèse est basé sur l’utilisation de nanotubes de carbone verticalement alignés, associée à des polymères fonctionnels. Les études se sont portées sur l’ensembledes résistances de contact existantes au sein d’un matériau d’interface thermique, depuis les nanotubes decarbone / Polymère / jusqu’au substrat de cuivre.L’optimisation des interactions est portée sur l’étude de différents polymères ayant la capacité d’engendrer des liaisons covalentes avec les nanotubes de carbone et avec le substrat de cuivre. L’intérêt de ces liaisons covalentes est d’améliorer le transfert de la chaleur via les phonons. Enfin, l’augmentation de la conductivité thermique intrinsèque des polymères est envisagée.Concernant les résultats obtenus, il apparait une nette diminution de chacune des résistances de contact étudiées. Afin de mieux comprendre ces résultats, des études de ces interfaces in-situ ont été réalisées. / With progress in microelectronics, the miniaturization of devices is a current issue and the component density on a device follows Moore’s law. As a consequence the power density reaches levels that challenge device reliability. New heat dissipation strategies are needed to efficiently drain heat.Thermal interface materials (TIMs) are used to transfer heat across interfaces, for example between the device and its packaging. However, to meet microelectronics requirement, commercials TIMs still need to be highly thermally conductive.In order to achieve these requirements, this work is focused on the use of vertically aligned carbon nanotubes (VACNTs) and functional polymers. All thermal contact resistances existing in TIMs, from VACNTs / Polymer / to substrate are studied.Interaction optimizations are based on the study of different polymers which are specially designed to develop covalent bonding with the CNTs sidewalls and/or metallic surface. The interest of these covalent bondings is to improve the thermal transfer by phonons. Finally, the increase of the intrinsic thermal conductivity of the polymer is considered.Regarding the results, a decrease of all thermal contact resistances is shown. In order to have a better understanding of these results, the thermal interfaces obtained are analyzed in situ.
3

Nanobulles et nanothermique aux interfaces / Nanobubbles and nanothermy across interfaces

Lombard, Julien 10 November 2014 (has links)
L'étude des nanobulles de vapeur générées autour de nanoparticules métalliques chauffées par un laser dans de l'eau a connu un intérêt croissant au cours de la dernière décennie, motivé notamment par leur utilisation potentielle pour des applications biomédicales. Ces travaux sont majoritairement expérimentaux et il n'existe pas de description complète des phénomènes physiques régissant la génération et la dynamique des nanobulles. L'objet de cette thèse est de répondre à ces questions fondamentales par la résolution numérique d'un modèle fondé sur les équations de conservation locales dans le fluide (masse, quantité de mouvement et énergie) et prenant en compte la thermodynamique du fluide, les effets capillaires et la résistance thermique à l'interface or-fluide. Par la résolution de ce modèle, nous avons accès à la thermodynamique du fluide avant sa vaporisation et pendant la durée de l'existence des nanobulles, ce qui permet la description de leur dynamique. Dans un second temps, nous définissons le critère de vaporisation dans le fluide par le franchissement de la température spinodale du fluide. Enfin, nous effectuons le bilan énergétique de la production et de la croissance des nanobulles, pour optimiser le transfert énergétique entre le laser et la nanobulle. Nous nous intéressons enfin à la conductance thermique d'interface due au couplage électron-phonon entre un métal et un diélectrique. Après avoir souligné l'influence de ce type de couplage sur le transfert énergétique interfacial, nous présentons des résultats préliminaires concernant le chauffage d'un fluide par des nanoparticules de type cœur-coquille or-silicium / Nanobubbles produced around metal nanoparticles heated by a laser pulse have received an increasing interest over the last decade. This interest is motivated by the possible use of those nanobubbles as an agent for cancer therapy. Existing studies are mainly experimental and a complete description of the mechanisms controlling the nanobubbles generation and evolution is still lacking. The aim of this thesis is to answer those fundamental issues by numerically solving a model based on the conservation equations inside the fluid (mass, momentum and energy). This model accounts for the thermodynamics of the fluid, capillary effects and a thermal interface resistance across the particle-fluid interface. Solving this model gives information about the thermodynamics of the fluid before and after its vaporization, which allows for the description of the bubbles dynamics. Then, we can define a criterion for bubbles generation, which corresponds to the crossing of the spinodal temperature of the fluid. Finally, we investigate the role played by the interface thermal resistance arising from electron-phonon couplings between a metal and a dielectric. We present some preliminary results concerning the heating of a fluid with core-shell nanoparticles
4

Analysis of Building Envelops to Optimize Energy Efficiency as per Code of Practice for Energy Efficient Buildings in Sri Lanka - 2008

Kumari, Epa January 2012 (has links)
Residential and commercial buildings consume approximately 20% of the global energy generation. This value is continuously growing and the governments across the globe have realized the importance of regulating the building construction to optimize the energy utilization. Energy efficient building codes have been developed to optimize the energy efficiency in buildings. OTTV (Overall Thermal Transfer Value) is a key parameter for evaluating energy efficiency of building envelops in the present building code of Sri Lanka. In this research, the prescriptive requirements mentioned in the building code for the building envelops to optimize the energy efficiency of five (05) commercial buildings has been analyzed. The indoor climate was modeled and the annual cooling energy variation with Overall Thermal Transfer Value was studied using “DesignBuilder” software. A cost benefit analysis was carried out for enhanced energy efficiency building envelops applications. It was attempted to develop a general relationship between the OTTV and annual cooling energy requirement for each building. It has been observed that a second order polynomial relationship with R2 of 0.861 exists for RDA building, linear relationship with R2 of 0.838 exists for AirMech building. However a specific relationship could not be observed for BMICH, SLSI and WTC buildings. The impact on cooling energy requirement from envelop parameter modification is unique for each building. In some instances the reduction of OTTV has not resulted in any reduction of the cooling energy requirement. There is a combined effect from each building component which affects the final cooling energy requirement. A simulation based technique to be used to find the optimum building envelops design.
5

Transport Thermique aux Interfaces : Angle Critique des Phonons, Transfert à Travers un Gap; Transfert Autour d'une Nanoparticule Colloïdale Cœur-Coquille / Thermal Transport at Interfaces : Phononic Critical Angle, Phonon Tunneling across a Vacuum Gap; Transfer around Core-Shell Colloidal Nanoparticles

Alkurdi, Ali 05 October 2017 (has links)
Cette thèse s'inscrit dans le domaine de la nanothermique, c'est à dire, l'étude des transferts de chaleur à l'échelle du nanomètre, pour lesquels la loi de Fourier n'est plus valide. A cette échelle, l'interface domine le transport thermique par sa résistance au flux d'énergie thermique. Cetterésistance se manifeste par une discontinuité de la température aux interfaces. Il est important de pouvoir la prédire afin de contrôler et aménager les flux thermiques dans les application en microélectroniques où la taille des transistors modernes devient nanomètrique. Le but de cette thèse est d'une part, d'étudier la transmission angulaire des phonons et prédire la résistance de Kapitza aux interfaces entre solides, de quantifier le transfert d'énergie assuré par les phonons au travers d'un gap de vide nanométrique, et d'autre part d'étudier le transfert thermique dans un système nanoparticule cœur-coquille immergé dans l'eau. Nous avons développé une nouvelle méthode de dynamique de réseau couplée à l'utilisation de constantes de force issus des calculs ab-initio. Cette méthode permet d'obtenir la transmission des phonons entre deux solides, en fonction de leur fréquence et vecteur d'onde, en tenant comptede la dispersion des phonons en volume dans les deux milieux. Nous avons également appliqué la méthode pour décrire le transfert thermique à travers un gap de vide entre deux solides. Enfin, nous nous sommes intéressés au transfert thermique autour d'une nanoparticule (NP) immergée dans l'eau et chauffée par un faisceau laser. Nous avons comparé l'efficacité de chauffage des NPs homogènes d'or à celles de type cœur-coquille or-silice / This thesis is devoted to the study of interfacial thermal transport at the nanoscale where Fourier’s law is not valid. This is because, at this scale, phonon mean free path becomes smaller to the characteristic length of the system, thus the heat transfer is no longer diffusive but rather ballistic. As a consequence, the thermal boundary resistance (TBR) becomes a determinant factor in heat transfer. The goal of this thesis is, firstly, to study phonon transmission and predict the thermal boundary conductance at interface between two solids. To this end, we have developed a new approach, which combines lattice dynamics calculations and inputs from ab initio, and we have applied our LD model to two types of solid structures: the face-centered cubic (FCC) crystal solid and the diamond-like crystal solid.Secondly, we aim to quantify the phononic contribution in heat transfer across a nanometric vacuum gap that separates two solids. We have used this ab initio LD model to predict the contribution of phonons in the heat transfer across a vacuum gap in two systems: the Au/vacuum-gap/Au and the Si/vacuum-gap/Si. Our results indicate that phonons do contribute significantly to heat transfer across a nanometric/subnanometric vacuum gap. Finally, we have investigated heat transfer in a system made of a core-shell nanoparticle (NP) immersed in water and heated by a laser pulse. We have used the four temperatures model, we have solved numerically the heat transfer equations in the system, taking into account the thermal boundary resistance (TBR) and the interfacial electron-phonon coupling
6

Analise numerica do desempenho termico de trocadores de calor de correntes cruzadas / Numerical analysis of thermal performance of crossflow heat exchangers

Tomazeti, Cristina Autuori 25 July 2006 (has links)
Orientador: Carlos Alberto Carrasco Altemani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-07T14:45:34Z (GMT). No. of bitstreams: 1 Tomazeti_CristinaAutuori_D.pdf: 4089449 bytes, checksum: 65558b112b34461f8da3f544b8666a0d (MD5) Previous issue date: 2006 / Resumo: Uma análise foi desenvolvida para avaliar o desempenho de trocadores de calor compactos de correntes cruzadas de placas aletadas com canais de seção transversal arbitrária. Os coeficientes convectivo e de atrito foram obtidos através de simulação numérica, tanto no regime de escoamento laminar quanto no turbulento, utilizando o pacote computacional PHOENICS. Estes resultados foram então usados junto com o método da efetividade para avaliar as características térmicas e de escoamento do trocador de calor. As simulações foram efetuadas inicialmente para o escoamento e a transferência de calor entre duas placas placa paralelas isotérmicas e bastante próximas, porque os resultados podiam ser comparados com aqueles disponíveis na literatura. Resultados numéricos adicionais foram obtidos, em seguida, para seis dutos de paredes isotérmicas com seções transversais distintas. Um deles era um duto retangular, e os outros cinco eram passagens típicas de placas aletadas utilizadas em trocadores de calor compactos. O fluido de trabalho era o ar e as simulações foram tridimensionais devido à presença das paredes das aletas. Perfis uniformes de velocidade e de temperatura sempre foram utilizados na entrada dos dutos, de forma que os resultados refletem os efeitos combinados de entrada hidrodinâmica e térmica. Os resultados para o duto retangular e o método da efetividade foram utilizados para prever o desempenho térmico de um trocador de calor de correntes cruzadas composto por um empilhamento de dutos retangulares idênticos. O desempenho deste trocador de calor foi avaliado também por uma simulação direta do escoamento cruzado e da transferência de calor através da parede de separação de dois dutos retangulares adjacentes do empilhamento. Os resultados obtidos foram bastante semelhantes, fornecendo confiança para a análise anterior. As simulações efetuadas para os cinco dutos típicos de placas aletadas de dimensões pequenas apresentaram resultados similares aos valores experimentais obtidos da literatura. Eles foram utilizados para avaliar o desempenho de trocadores de calor compactos de correntes cruzadas compostos por empilhamentos destas placas aletadas. Vários parâmetros como o volume total, o peso, a potência de bombeamento, a efetividade, a taxa de geração adimensional de entropia, e a eficiência exergética também foram avaliados para comparar os trocadores compactos de calor considerados / Abstract: An analysis was developed to evaluate the performance of cross flow compact heat exchangers with plate-fin passages of arbitrary cross section. The convective and the friction coefficients were obtained by numerical simulation, either in the laminar or the turbulent flow regimes, using the software PHOENICS. These results were then employed together with the effectiveness method to evaluate the heat exchanger thermal and flow characteristics. The simulations were performed initially for the flow and heat transfer between two closely spaced parallel isothermal plates, because the results could be compared with those available in the literature. Additional numerical results were obtained, next, for six isothermal wall ducts with distinct cross sections. One was a rectangular duct, and the other five were typical plate-fin passages employed in compact heat exchangers. The working fluid was air and the simulations were three dimensional due to the fins walls. Uniform velocity and temperature profiles were always assumed at the duct inlet, so that the results reflected the combined effects of hydrodynamic and thermal entrance. The results for the rectangular duct and the effectiveness method were employed to predict the thermal performance of a cross flow heat exchanger made from a stack of identical rectangular ducts. The performance of this heat exchanger was also evaluated by a direct simulation of the cross flow and the heat transfer through the separating wall of two adjacent rectangular ducts of the stack. The results compared favorably, lending confidence to the previous analysis. The simulations performed for the five typical plate-fin passages of small cross section presented results similar to the experimental values obtained from the literature. They were used to evaluate the performance of cross flow compact heat exchangers composed of stacks of these plate-fins. Several parameters like total volume, weight, pumping power, effectiveness, rate of dimensionless entropy generation, and exergetic efficiency were also evaluated to compare the distinct compact heat exchangers / Doutorado / Termica e Fluidos / Mestre em Engenharia Mecânica
7

Cogénération héliothermodynamique avec concentrateur linéaire de Fresnel : modélisation de l’ensemble du procédé / Concentrating solar power based cogeneration with Linear Fresnel Collector : modelling of the whole process

Veynandt, François 01 December 2011 (has links)
Le concentrateur à réflecteur linéaire de Fresnel (LFR) est une technologie solaire thermodynamique en plein essor : petites applications industrielles (chaleur, froid, électricité) à centrales électriques (10-100 MWel). Ce travail de thèse établit un modèle global du procédé solaire, en régime permanent, pour un prédimensionnement du système. Le modèle comprend trois parties chaînées : (i) les transferts radiatifs dans le concentrateur optique, modélisés précisément par une méthode de Monte Carlo (environnement EDStar) ; (ii) les transferts thermiques dans le récepteur, évalués analytiquement (puissances, températures) ; (iii) le cycle thermodynamique, avec Thermoptim. L’application étudiée couple un concentrateur LFR à un moteur Ericsson. L’air est fluide caloporteur et de travail. Un prototype est en construction. L’hybridation et le stockage thermique sont des options clés. Un modèle systémique permettrait d’optimiser l’opération du procédé, en étudiant son comportement dynamique. / Linear Fresnel Reflector (LFR) is a promising Concentrating Solar Power technology. Research is booming and industrial applications are emerging. Applications range from small production units (heat, cold, electricity) to utility scale power plants (several tenths of MW). This PhD work establishes a global model of the solar process, in order to improve our knowledge of the system’s performances. It is a static model suited for a pre-design of the system. The model is chaining three parts. Radiative heat transfer in the optical concentrator is modelled by Monte Carlo statistical Method. The algorithm enables a detailed study of any geometrical configuration, especially through absorbed power flux maps on the receiver. The simulation tool is using the environment of development EDStar. The thermal model calculates analytically the useful thermal power, losses and temperature profiles along the receiver (glass cover, fluid, pipe...). The thermodynamic cycle is simulated analytically using the software Thermoptim. The studied application uses air as heat transfer and working fluid. Air directly feeds an Ericsson engine. The engine developed by LaTEP laboratory is promising for small scale cogeneration (1 to several tenths of kWel). The prototype Linear Fresnel Reflector built in Ecole des Mines d’Albi will enable experimental study of a solar process coupling an LFR concentrator and an Ericsson engine. The technology under study can feed a power plant or a cogeneration system in the industry, producing electricity and heat at 100 to 250°C. Hybridisation with an other energy source (biomass, gas...) and thermal storage (molten salt?) are key features to investigate. To optimise the operating strategy of the process, dynamic behaviour must be studied: a systemic or agent based model is a very relevant approach.
8

Torche à plasma micro-onde à la pression atmosphérique : transfert thermique / Microwave plasma torch at atmospheric pressure : thermal transfer

Gadonna, Katell 23 April 2012 (has links)
Parmi les torches à plasma microonde, la torche à injection axiale (TIA) est utilisée depuis de nombreuses années pour créer des espèces chimiquement actives dans des applications comme l'analyse de gaz, les traitements de surface et les traitements d'effluents gazeux. Notre étude porte sur l'énergie transférée par le plasma créé par cette torche à pression atmosphérique, qui trouve son intérêt notamment dans le chauffage de l'hélium pour la montée en altitude d'un ballon dirigeable. La TIA permet de coupler de l'énergie microonde (2.45 GHz) à un gaz injecté axialement à la sortie d'une buse. La TIA donne lieu à un plasma hors équilibre thermodynamique formé d'un dard de forte luminosité, avec une densité maximale de particules chargées à la sortie de la buse. Notre étude porte sur l'expérience et la modélisation de cette torche pour comprendre la répartition du champ électromagnétique, l'écoulement du système gaz/plasma et le transfert de chaleur du plasma au gaz.Des mesures par spectroscopie optique d'émission dans l'argon et l'hélium ont permis de trouver les températures du gaz (1500 K vs 3000 K) en fonction des conditions expérimentales (débit, puissance). Elles ont été estimées en ajustant les spectres ro-vibrationnels de N2 obtenus à ceux issus du logiciel SPECAIR. La mesure de la densité électronique (de l'ordre de quelques 10^14 cm^-3) a été réalisée dans un plasma d'hélium par élargissement Stark de la raie Hβ. Ces mesures ont un double objectif : obtenir des données d'entrée au modèle et valider ses résultats.La modélisation se partage en deux modules réalisés avec le logiciel COMSOL Multiphysics: (i) un module électromagnétique 3D qui résout les équations de Maxwell, (ii) un module hydrodynamique 2D qui résout les équations de Navier-Stokes pour le système gaz/plasma en prenant en compte les ions. Un module plasma, en cours de développement, résoudra les équations fluides pour les électrons et les ions du plasma.Cette modélisation réussit à prédire des températures similaires à celles obtenues expérimentalement et a permis de montrer l'influence du plasma sur l'écoulement et la température du gaz ainsi que l'efficacité du transfert de chaleur du plasma au gaz. / Among the microwave plasma torches, the axial injection torch (TIA) has been used for several years to create chemically active species, in applications such as gas analysis, surface processing and gaseous waste treatments. Our study concerns the energy transferred from the plasma created by the torch at atmospheric pressure, which finds its interest in particular in the heating of helium in a dirigible balloon to achieve its rise in altitude. The TIA allows the coupling of microwave energy (2.45 GHz) with a gas injected axially at the nozzle's exit. The TIA produces a non equilibrium plasma with a high luminosity and a maximum density of charged particles at the nozzle's exit. Our study involves both experiment and modelling of this torch in order to understand the distribution of the electromagnetic field, the flow of gas / plasma system and the plasma-to-gas heat transfer.Measurements by optical emission spectroscopy in argon and helium allowed to determine the gas temperature (1500K vs 3000 K) based on experimental conditions (flow, power). They were estimated by fitting the N2 ro-vibrational spectra obtained from air, using the SPECAIR software. The measurement of electron density (of about a few 10^14 cm^-3) was performed in a helium plasma by Stark broadening of the Hβ. Experiments have a double objective : to obtain input data for the model and to validate its results. Modelling uses two modules of the COMSOL Multiphysics software: (i) a 3D electromagnetic module, which solves Maxwell's equations, (ii) a 2D hydrodynamic module, which solves the Navier-Stokes equations for the gas / plasma system taking into account the ions. A plasma module, which solves the fluid equations for electrons and ions is in development This modelling succeeded in predicting temperatures similar to those obtained experimentally and showed the influence of plasma upon flow and the gas temperature and the efficiency of heat transfer from the plasma to the gas.
9

Modélisation couplée Compatibilité Électromagnétique - Thermique d’architectures de câblages électriques embarquées / Coupled EMC - Thermal Modeling of Electrical Wiring Architectures Embedded

Mahiddini, Florian 24 May 2018 (has links)
Le développement d’aéronefs « plus » voire « tout » électriques a pour conséquence la conception d’architectures électriques embarquées de plus en plus complexes entraînant une très nette augmentation du nombre de câbles électriques à déployer au sein des véhicules. Parmi les contraintes rencontrées lors des phases de définition et d’intégration des réseaux de câblages, les aspects de compatibilité électromagnétique et de gestion des échauffements thermiques deviennent de plus en plus critiques. Ainsi, ces travaux de thèse sont dédiés au développement d’une méthodologie permettant la prédiction d’une part, des courants induits par et sur les réseaux de câblages et d’autre part, de leur niveaux d’échauffement. En particulier, l’analyse bibliographique effectuée à cette occasion montre que les phénomènes électrostatiques (à la base de la théorie des lignes de transmission) et de conduction stationnaire de la chaleur sont strictement analogues, ce qui autorise une résolution simultanée de ces deux problèmes pour les réseaux de câblages considérés. Les présents travaux démontrent que le calcul des paramètres électriques primaires (p.u.l) du réseau et de la distribution de température dans le plan transverse peut se faire de manière totalement couplé à l’aide d’un schéma numérique basé sur la Méthode des Moments(MoM). Le choix de l’utilisation des équations intégrales pour la résolution de ce problème de potentiel se fonde sur plusieurs avantages tels qu’une utilisation optimisée des ressources de calcul et l’utilisation d’algorithmes efficaces de résolution, de surcroît naturellement parallélisables pour de futurs développements. Les outils de calculs thermiques développés dans le cadre de cette thèse, et qui ont vocation à être intégrés dans la suite logicielle CRIPTE de l’ONERA, ont fait l’objet d’une validation expérimentale pour plusieurs configurations de harnais électriques. Les comparaisons simulations-mesures présentent de bons accords bien que les expérimentations menées aient montré la difficulté d’obtenir précisément des valeurs du coefficient d’échange thermique,même dans des conditions parfaitement maîtrisées. Les travaux ouvrent enfin des perspectives nouvelles sur l’optimisation en terme de masse des réseaux de câblage (EWIS). / The on-going development of “more” or “all” electrical aircraft leads to the design of ever-complex embeddedelectrical networks, which causes a significant increase of electrical cables to be used within these innovativevehicles. Among the constraints encountered during the definition and integration phases of the network, thoserelated to the electromagnetic compatibility between equipment as well as the management of thermal heatingby Joule’s effect become more and more stringent. Thus, this thesis is dedicated to the development of anoriginal methodology enabling the prediction of both induced and crosstalk currents as well as the heating upstate in complex bundles of cables. Indeed, literature review explicitly shows that electrostatic and stationaryheat transfer phenomena are, from a mathematical standpoint, strictly the same which allows the simultaneouscomputation of these two problems for an arbitrary network. This research work demonstrates that the determinationof primary electrical parameters (per unit length) and the temperature distribution within a givencross-section can be handled with the numerical Method Of Moment (MoM). This choice is motivated by theseveral inherent advantages of the method like an optimized use of the computer resource and the naturalparallelization of the algorithms. The developed numerical tools, intended to be fully integrated in the in-housesoftware suite CRIPTE, has been validated during an experimental campaign that has involved several typesof bundles. Although the comparisons between experimental and simulated results comply with each other,experiments reveal the hard task of getting a precise estimation of the heat transfer coefficients, even in awell-controlled environment. Finally, these works open new and very promising perspectives for future EWIS(Electrical Wiring Interconnection System) in term of mass optimization.
10

Étude hydrodynamique et thermique d'un nouveau concept de récepteur solaire à suspensions denses gazparticules / Hydrodynamic and Thermal Study of a New Concept of Solar Receiver using Dense Suspensions of Particles

Boissière, Benjamin 17 April 2015 (has links)
Parmi les centrales solaires thermiques à concentration, la technologie des centrales à tour offre l'un des rendements les plus importants de production d'énergie. Néanmoins, l'efficacité et la sécurité de ces centrales sont améliorables. En effet, les sels fondus, généralement utilisés comme fluide de transfert thermique, présentent une plage limitée d'utilisation (200-550°C), à l'origine des limites d'efficacité de la conversion thermique-électrique, ainsi que de consommations parasites d'énergie de chauffage. De plus, leurs caractères corrosif et comburant sont à l'origine de sévères contraintes de sécurité. Un nouveau concept de récepteur solaire, dont les caractéristiques permettent de s'affranchir des contraintes associées aux sels fondus, est présenté dans ce manuscrit. Il utilise des suspensions denses de particules fluidisées par un gaz comme fluide de transfert et de stockage de l'énergie thermique. Ce concept, et la technologie de récepteur associée, a été brevetée par Flamant et Hemati dans le cadre d'une collaboration entre le Laboratoire CNRS-PROMES d'Odeillo, et l'Institut National Polytechnique de Toulouse. Son développement a reçu le soutien financier du CNRS, puis de la Commission Européenne. Les propriétés thermiques du carbure de silicium ont déterminé le choix de ce solide. Le diamètre moyen des particules utilisées avoisine 60 micromètres (groupe A). Ces particules présentent d'excellentes propriétés de fluidisation pour des vitesses de gaz faibles. La construction et l'exploitation d'une maquette froide transparente ont permis de démontrer la faisabilité hydrodynamique du concept. Cette maquette est un échangeur à deux passes. Chaque passe est constituée de deux tubes verticaux en parallèle. L'une est traversée par un débit vertical ascendant de solide, l'autre descendant. Un débit de solide continu, stable et équitablement réparti a été obtenu à l'intérieur des tubes. La caractérisation hydrodynamique détaillée de l'écoulement, et du comportement globale de la maquette, en fonction des conditions opératoires, a été effectué sur la partie ascendante de l'écoulement dans l'échangeur. La construction et l'exploitation d'une maquette chaude, constituée d'un seul tube traversé par une suspension dense en écoulement ascendant, chauffé par 3 fours d'une puissance totale de 5,6 kW, a permis d'estimer la capacité de transfert thermique de ce nouveau type d'échangeur. Le contrôle et la stabilité des conditions opératoires a permis d'évaluer l'effet de ces dernières sur le transfert thermique entre l'échangeur et la suspension dense de fines particules le traversant. La modélisation par 3 approches du transport ascendant de la suspension dense a également été réalisée. Une approche corrélative 1D basée sur le formalisme du modèle Bulle-Emulsion, adapté afin de tenir compte de l'entraînement des particules dans le sillage des bulles. Ce modèle permet de représenter la structure diphasique de l'écoulement. Une autre approche 1D a été utilisée. Elle repose sur la résolution des équations locales de conservation de masse et de quantité de mouvement sur chaque phase gaz et solide. Cette méthode permet de s'affranchir des hypothèses du modèle Bulle-Emulsion. Enfin, la simulation numérique 3D a été réalisée sur un maillage complet du système, de telle sorte que les conditions aux bornes imposées son identiques à celle imposée par l'opérateur (débit de fluidisation, débit d'aération, débit de solide, pression de la nourrice). Cette dernière apporte des informations sur la structure locale de l'écoulement, dont les caractéristiques permettent d'expliquer l'efficacité du transfert thermique entre la suspension et la paroi observé expérimentalement. / Among concentrating solar power plants, solar tower technology is one of the more power efficient. Nevertheless, their efficiency and safety can be improved. Indeed, molten salts, commonly used as heat transfer fluid, have a limited range of operating temperature (470-820K), thus lowering the thermal-electrical conversion efficiency, and increasing parasitic power consumption. Moreover, they are corrosive and combustion agent, leading to severe safety constraints. A new concept of solar receiver is presented in the present study, the characteristics of which avoid most of the molten salts drawbacks. It uses dense gas-particle suspension as heat transfer and storage fluid. This concept and the associated technology has been patented by Flamant et Hemati in the frame of a collaboration between the PROMES-CNRS Laboratory of Odeillo and the Polytechnic National Institute of Toulouse. Its development has been first supported by the CNRS, and later by the European Commission. Thermal properties of silicon carbide have determined the choice of this solid. The mean diameter of particles is around 64 microns (A group). These particles have excellent fluidisation properties at low gas velocities. The construction and the operation of a transparent cold mockup allowed demonstrating the hydrodynamic feasibility of this concept. This mockup is composed of two passes. Each pass is composed of two tubes in parallel. One pass is upward flow of solid, the other is downward flow. A steady, stable and evenly distributed solid flow has been set inside the tubes. The global behaviour of the system and the hydrodynamics of the suspension has been evaluated as a function of operating parameters on the upward pass. The construction and the operation of a hot mockup allowed estimating the heat transfer efficiency of this new kind of exchanger. On this mockup, the dense suspension flows upward inside a single tube, heated by three ovens of 5.6 kW total power. Thanks to the control and stability of the operating parameters, their effects on the heat transfer between the tube and the dense gas-solid suspension has been accurately determined. Modelling of the suspension upward flow has been performed using 3 approaches. The first one is based on the 1D Bubble-emulsion formalism, adapted to take into account the solid entrainment by the bubble wakes. It allows modelling the diphasic structure of the flow. The resolution of the local mass and momentum balance equation on each phase has also been performed. It allows to sidestep the Bubble-Emsulion assumptions, and to study the effects of drag models. 3D simulation has been performed on a complete mesh of the system, so that the boundary conditions are the same as those imposed by the operator (fluidisation flow rate, aeration flow rate, solid flow rate, dispenser pressure). These simulations give information on the local structure of the suspension flow, influencing on the heat transfer efficiency between the exchanger wall and the suspension.