• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 8
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 34
  • 11
  • 8
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Neue Synthesen und Reaktionen von Vinylthiocyanaten

Müller, Anett. January 1999 (has links)
Chemnitz, Techn. Universiẗat, Diss., 1999. / Dateien im PS-Format.
2

Role of the lactoperoxidase system in raw milk preservation

Fonteh, Florence Anyangwe January 2001 (has links)
No description available.
3

A review of the pharmacology and use of thiocyanate in the treatment of hypertension

O'Brien, Arthur January 1946 (has links)
Thesis (M.D.)--Boston University
4

Estudo espectrofotométrico do sistema cobalto(II)/tiocianato e seu aproveitamento analítico / Spectrophotometric study of cobalt(II)/thiocyanate system and its analytical use

Sader, Ana Paula de Oliveira 09 December 2002 (has links)
Estudos sobre a formação dos complexos de metais, seus equilíbrios e, também, o aproveitamento analítico desses diferentes sistemas constituem uma tradicional linha de pesquisa em Química. Mais especificamente, as espécies formadas entre os vários pseudo-haletos e outros ligantes, com muitos cátions dos metais de transição, vêm sendo sistematicamente investigadas em nossos laboratórios de Química Analítica. Nesta linha, o emprego do íon tiocianato como ligante tem se destacado dentre os métodos analíticos para a determinação de cobalto, cuja procura tem sido crescente à medida que o homem, ao longo de sua evolução, descobre e produz novos materiais contendo esse metal. Desta forma, tendo em vista algumas características típicas do sistema Co(II)/SCN-, tal como sua intensa coloração, objetivou-se, nesta oportunidade, explorá-lo espectrofotometricamente com maior profundidade. Conseqüentemente, diversos parâmetros envolvidos na complexação dos íons cobalto (II) pelo tiocianato, tais como: a acidez do meio, a concentração disponível de ligante e a presença de solventes orgânicos no sistema, tiveram seus efeitos avaliados individualmente. Com os resultados destes estudos, estabeleceram-se as condições experimentais otimizadas para a montagem do método analítico, visando a determinação de íons cobalto(II). São elas: C (HClO4) =0,050 mol L-1 C (SCN-)=0,203 mol L-1 C(THF)=60% (v/v) Através de estudos espectrofotométricos preliminares, observou-se que o sistema apresenta dois máximos de absorção nestas condições experimentais: 316 e 622 nm, sendo esta última banda, aquela normalmente utilizada neste tipo de trabalho. Estudos de calibração nos dois comprimentos de onda indicaram que as leituras obedecem fielmente à lei de Beer em ambos os casos, porém com sensibilidade significativamente maior na região ultravioleta (E(316nm)= 1,20 x 104 e E(622nm)= 1,95 x 103 L mol-1 cm-1). Outros estudos sobre estabilidade, repetibilidade (precisão) e de possíveis interferentes também foram realizados, sendo os resultados bastante satisfatórios para fins analíticos. Observou-se interferência das espécies: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+, Cd2+, quando presentes em concentrações cem vezes superiores à de cobalto(II). Entretanto, tal efeito desaparece quando estes íons acham-se em concentrações dez vezes maior do que a do metal de interesse. Aplicações analíticas do método proposto foram testadas em um produto farmacêutico (vitamina B12) e em uma liga odontológica, com resultados plenamente satisfatórios, já que os erros percentuais obtidos ficaram dentro da faixa aceitável (< 5%). A técnica de espectroscopia de absorção atômica foi utilizada paralelamente nestas análises, para efeito comparativo, na qual a determinação de cobalto mostrou-se possível na liga odontológica, mas inadequada para o fármaco (erro da ordem de 20%), nas condições de abertura realizadas. A comparação dos resultados mostra a potencialidade do método proposto, tendo em conta a simplicidade, exatidão e custo das aparelhagens. Finalizando, a possível influência do níquel (presente naturalmente em diversas amostras reais) na determinação de cobalto foi avaliada sob as condições experimentais estabelecidas para o método espectrofotométrico proposto. Observou-se que este “contaminante" natural exibe um pico de absorção em 245 nm e, através dos estudos, confirmou-se a aditividade das absorbâncias dos respectivos complexos (Co e Ni). Testou-se a possibilidade de determinação espectrofotométrica simultânea destes dois metais, através de leituras nos respectivos máximos (245 e 316 nm), empregando-se um sistema algébrico com duas equações simples, cujos resultados foram plenamente satisfatórios. As faixas úteis de trabalho, em termos de concentrações de cobalto e níquel foram, respectivamente: 0,94 a 4,04 mg L-1 e 28,7 a 123,7 mg L-1, respectivamente. / Studies about the formation of metallic complexes, their equilibria and also the analytical utilization of these different systems represent a traditional research line in Chemistry. More specifically, the species formed among the various pseudohalides and other ligands, with several cations of transition metals, have been systematically investigated in our Laboratories. The use of the thiocyanate ion as ligand has been intensive from among the analytical methods for cobalt(II) determination, of which interest has increased more recently, according to the man discovers and production of new materials containing this metal. Due some typical characteristics of the system Co(II)/SCN-, such as its colored complexes, the principal purpose of this study was to explore it more carefully by visible-ultraviolet spectrophotometry. Consequently, several parameters involved in the cobalt(II)/thiocyanate complexes formation, such as acidity level, concentration of free ligand, and the percentage of organic solvents in the system, had their respective effects evaluated individually. Through the results of these diverse studies, appropriate experimental conditions were established for the analytical methods, for the determination of the cobalt(II) ion. They are: C (HClO4)=0.050 mol L-1 C (SCN-)=0.203 mol L-1 C(THF)=60% (v/v) Preliminary spectrophotometry studies showed two absorption maxima (peaks) under these optimized experimental conditions: 316 and 622 nm, being this last visible band normally applied for this type of work (determination). Calibration studies at these two wavelengths showed that the Beer’s Law is obeyed in both cases, but a higher sensitivity was obtained in the ultraviolet region ( E(316nm)= 1.20 x 104 e E(622nm)= 1.95 x 103 L mol-1 cm-1). Other studies about stability, precision, accuracy and possible interferences were also performed, showing satisfactory results for the analytical purposes. It was observed some interference of the following species: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+ and Cd2+, when present in concentrations one hundred times higher than the cobalt(II). However, this effect disappears when these ions are presented on concentration just ten times higher. Analytical applications of the proposed method were tested for a pharmaceutical product (B12 vitamin) and for an odontological alloy, with large success, since the percentage of error was within the tolerance range (<5%). Atomic absorption spectroscopy was also used in this analysis for comparision, in which the cobalt determination was possible for the alloy but inadequate for the pharmaceutical product (error about 20%). Comparison of the results shows the potentiality of this alternative spectrophotometric method, taking in account its simplicity, accuracy and equipments prices. Finally, the influence of nickel (naturally present in several real samples) on the spectrophotometric cobalt determination was evaluated, under the optimized experimental conditions. It was observed that this natural “contaminating" exhibits an absorption peak at 245 nm. Other confirmatory studies show the additivities of the respective absorbances (nickel and cobalt/thiocyanate complexes), allowing the simultaneous spectrophotometric determination of these these metals, using a matematical system with two equations (peaks 245 and 316 nm). This attempt was well satisfactory and the useful concentration ranges for cobalt and nickel were, respectively, 0.94 to 4.04 mg L-1 and 28.7 to 123.7 mg L-1.
5

Estudo espectrofotométrico do sistema cobalto(II)/tiocianato e seu aproveitamento analítico / Spectrophotometric study of cobalt(II)/thiocyanate system and its analytical use

Ana Paula de Oliveira Sader 09 December 2002 (has links)
Estudos sobre a formação dos complexos de metais, seus equilíbrios e, também, o aproveitamento analítico desses diferentes sistemas constituem uma tradicional linha de pesquisa em Química. Mais especificamente, as espécies formadas entre os vários pseudo-haletos e outros ligantes, com muitos cátions dos metais de transição, vêm sendo sistematicamente investigadas em nossos laboratórios de Química Analítica. Nesta linha, o emprego do íon tiocianato como ligante tem se destacado dentre os métodos analíticos para a determinação de cobalto, cuja procura tem sido crescente à medida que o homem, ao longo de sua evolução, descobre e produz novos materiais contendo esse metal. Desta forma, tendo em vista algumas características típicas do sistema Co(II)/SCN-, tal como sua intensa coloração, objetivou-se, nesta oportunidade, explorá-lo espectrofotometricamente com maior profundidade. Conseqüentemente, diversos parâmetros envolvidos na complexação dos íons cobalto (II) pelo tiocianato, tais como: a acidez do meio, a concentração disponível de ligante e a presença de solventes orgânicos no sistema, tiveram seus efeitos avaliados individualmente. Com os resultados destes estudos, estabeleceram-se as condições experimentais otimizadas para a montagem do método analítico, visando a determinação de íons cobalto(II). São elas: C (HClO4) =0,050 mol L-1 C (SCN-)=0,203 mol L-1 C(THF)=60% (v/v) Através de estudos espectrofotométricos preliminares, observou-se que o sistema apresenta dois máximos de absorção nestas condições experimentais: 316 e 622 nm, sendo esta última banda, aquela normalmente utilizada neste tipo de trabalho. Estudos de calibração nos dois comprimentos de onda indicaram que as leituras obedecem fielmente à lei de Beer em ambos os casos, porém com sensibilidade significativamente maior na região ultravioleta (E(316nm)= 1,20 x 104 e E(622nm)= 1,95 x 103 L mol-1 cm-1). Outros estudos sobre estabilidade, repetibilidade (precisão) e de possíveis interferentes também foram realizados, sendo os resultados bastante satisfatórios para fins analíticos. Observou-se interferência das espécies: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+, Cd2+, quando presentes em concentrações cem vezes superiores à de cobalto(II). Entretanto, tal efeito desaparece quando estes íons acham-se em concentrações dez vezes maior do que a do metal de interesse. Aplicações analíticas do método proposto foram testadas em um produto farmacêutico (vitamina B12) e em uma liga odontológica, com resultados plenamente satisfatórios, já que os erros percentuais obtidos ficaram dentro da faixa aceitável (< 5%). A técnica de espectroscopia de absorção atômica foi utilizada paralelamente nestas análises, para efeito comparativo, na qual a determinação de cobalto mostrou-se possível na liga odontológica, mas inadequada para o fármaco (erro da ordem de 20%), nas condições de abertura realizadas. A comparação dos resultados mostra a potencialidade do método proposto, tendo em conta a simplicidade, exatidão e custo das aparelhagens. Finalizando, a possível influência do níquel (presente naturalmente em diversas amostras reais) na determinação de cobalto foi avaliada sob as condições experimentais estabelecidas para o método espectrofotométrico proposto. Observou-se que este “contaminante” natural exibe um pico de absorção em 245 nm e, através dos estudos, confirmou-se a aditividade das absorbâncias dos respectivos complexos (Co e Ni). Testou-se a possibilidade de determinação espectrofotométrica simultânea destes dois metais, através de leituras nos respectivos máximos (245 e 316 nm), empregando-se um sistema algébrico com duas equações simples, cujos resultados foram plenamente satisfatórios. As faixas úteis de trabalho, em termos de concentrações de cobalto e níquel foram, respectivamente: 0,94 a 4,04 mg L-1 e 28,7 a 123,7 mg L-1, respectivamente. / Studies about the formation of metallic complexes, their equilibria and also the analytical utilization of these different systems represent a traditional research line in Chemistry. More specifically, the species formed among the various pseudohalides and other ligands, with several cations of transition metals, have been systematically investigated in our Laboratories. The use of the thiocyanate ion as ligand has been intensive from among the analytical methods for cobalt(II) determination, of which interest has increased more recently, according to the man discovers and production of new materials containing this metal. Due some typical characteristics of the system Co(II)/SCN-, such as its colored complexes, the principal purpose of this study was to explore it more carefully by visible-ultraviolet spectrophotometry. Consequently, several parameters involved in the cobalt(II)/thiocyanate complexes formation, such as acidity level, concentration of free ligand, and the percentage of organic solvents in the system, had their respective effects evaluated individually. Through the results of these diverse studies, appropriate experimental conditions were established for the analytical methods, for the determination of the cobalt(II) ion. They are: C (HClO4)=0.050 mol L-1 C (SCN-)=0.203 mol L-1 C(THF)=60% (v/v) Preliminary spectrophotometry studies showed two absorption maxima (peaks) under these optimized experimental conditions: 316 and 622 nm, being this last visible band normally applied for this type of work (determination). Calibration studies at these two wavelengths showed that the Beer’s Law is obeyed in both cases, but a higher sensitivity was obtained in the ultraviolet region ( E(316nm)= 1.20 x 104 e E(622nm)= 1.95 x 103 L mol-1 cm-1). Other studies about stability, precision, accuracy and possible interferences were also performed, showing satisfactory results for the analytical purposes. It was observed some interference of the following species: I-, Al3+, IO3-, Mn2+, NO2-, BrO3-, S2O32-, Hg2+ and Cd2+, when present in concentrations one hundred times higher than the cobalt(II). However, this effect disappears when these ions are presented on concentration just ten times higher. Analytical applications of the proposed method were tested for a pharmaceutical product (B12 vitamin) and for an odontological alloy, with large success, since the percentage of error was within the tolerance range (<5%). Atomic absorption spectroscopy was also used in this analysis for comparision, in which the cobalt determination was possible for the alloy but inadequate for the pharmaceutical product (error about 20%). Comparison of the results shows the potentiality of this alternative spectrophotometric method, taking in account its simplicity, accuracy and equipments prices. Finally, the influence of nickel (naturally present in several real samples) on the spectrophotometric cobalt determination was evaluated, under the optimized experimental conditions. It was observed that this natural “contaminating” exhibits an absorption peak at 245 nm. Other confirmatory studies show the additivities of the respective absorbances (nickel and cobalt/thiocyanate complexes), allowing the simultaneous spectrophotometric determination of these these metals, using a matematical system with two equations (peaks 245 and 316 nm). This attempt was well satisfactory and the useful concentration ranges for cobalt and nickel were, respectively, 0.94 to 4.04 mg L-1 and 28.7 to 123.7 mg L-1.
6

Hybrid inorganic heterostructures and methods of fabricating p-type semiconductors for optoelectronic devices

Liang, Jian Wei 11 1900 (has links)
For III-nitride wide-bandgap materials, the lack of efficient p-type wide bandgap semiconductors limits the full potential of group-III nitride-based optoelectronic devices. Conventional wide bandgap p-type materials consisting of magnesium-doped gallium nitride (GaN:Mg) and magnesium-doped aluminum gallium nitride (AlGaN:Mg) typically exhibit low hole carrier concentrations of <1018 cm-3 . Hence, I used different wide bandgap inorganic p-type materials as a promising solution, e.g., copper thiocyanate (CuSCN). CuSCN has multiple attractive properties that hold potential for applications in III-nitride materials. For example, its energy band gap is up to 3.9 e.V and its electron effective mass is higher than its hole effective mass. These two key features make CuSCN a potential wide bandgap p-type material for III-nitride systems. By exposing CuSCN to chlorine, Cl2-infused CuSCN thin film achieves a hole concentration up to 3 × 1018 cm-3 and maintains its visible-light-blind optical properties. Based on these desirable features, p CuSCN/n-GaN heterojunction ultraviolet photodetectors, as well as the p-CuSCN and n GaN interface, were fabricated to investigate the potential applications of p-CuSCN in III nitride devices. Moreover, p-CuSCN also benefits the corresponding organic solar cells; p CuSCN-based organic solar cells perform better in power conversion efficiency and stability tests under various conditions than intrinsic CuSCN-based organic solar cells. This work on p-CuSCN not only paves the way for new III-nitride semiconductor devices, but may also potentially enable the development of organic devices with better performance and longer lifetime. To explore the potential of transition metal oxides in UV photodetectors, NiO was selected to proceed with device fabrication because of its wider energy bandgap and lower hole effective mass than other transition metal oxides. Since single crystal quality is required to maintain its visible-light-blind optical property, brand-new templates were invented to grow single-crystal NiO thin films, TiN/MgO, and TiN/Si. Use of TiN thin film between NiO and the substrates provides a good back-side metal contact for NiO-based semiconductor devices. Several tools were employed to ascertain the single-crystal quality of as-grown NiO thin films on TiN/MgO and TiN/Si. I demonstrate NiO/TiN/MgO and NiO/TiN/Si bilayer structures may pave the way towards better NiO-based ultraviolet optoelectronic devices.
7

Estudo espectrofotométrico de oxidação no sistema Ferro(II)/Tiocianato e seu aproveitamento analítico. / Spectrophotometric study of oxidation in the Iron(II)/Thiocyanate system and some analytical applications.

Martins, Fernando Grine 19 July 2002 (has links)
Uma das linhas mais tradicionais de trabalho na área da Química é a de formação de complexos. Em nossos laboratórios tal, estudo é realizado de modo sistemático, geralmente envolvendo pseudo-haletos e haletos com cátions de metais de transição. As intensas colorações produzidas pela maioria das reações de complexação, entre um pseudo-haleto e um metal, têm sido bastante exploradas espectrofotometricamente para a determinação individual ou a especiação do respectivo metal. A forte cor vermelha característica de complexos formados entre o ferro e o tiocianato é uma das maiores evidências da analogia existente entre os ligantes tiocianato e azoteto (N3-). A pouca sensibilidade dos complexos formados no sistema Fe3+/SCN-, em meio aquoso, dificulta a aplicação de métodos clássicos fotométricos mais rigorosos. Estudos feitos em nossos laboratórios, em presença de alguns solventes e usando ferro-II, têm mostrado uma rápida oxidação do metal, seguida por imediata complexação, o que vêm possibilitando novas estratégias para se determinar o total de ferro em uma amostra, bem como a sua especiação. Objetivando dar continuidade a linha de pesquisa, que envolve o estudo da oxidação do ferro-II, vários parâmetros que afetam a velocidade de oxidação neste sistema reacional, assim como: acidez, concentração de ligante, temperatura e presença de solvente orgânico, foram cuidadosamente verificados. Reunindo as condições ideais necessárias para o estudo de complexação utilizando íons ferrosos, sendo elas: C H+ = 30 mmolL-1 C SCN- = 250 mmolL-1 CAcetona = 70 % (v/v) T = 25ºC &#955;máx = 480nm tempo de espera = 7 minutos Após a sondagem espectrofotométrica do sistema, foram realizados estudos de calibração, de estabilidade, de precisão e de possíveis interferentes. A curva analítica espectrofotométrica, para a determinação de ferro total, obedece à lei de Beer (r = 0,9993), mostrando a potencialidade de aproveitamento analítico desse sistema. O valor da absortividade molar média (e) determinado foi da ordem de 2,10.104 mol-1. L.cm-1. A faixa ideal de trabalho para a determinação de ferro é de 1 a 8 ppm. Comprovou-se uma boa precisão, bem como uma constância de leituras ótima para fins analíticos. Apenas as espécies NO2-, S2032-, C2042-, HPO42-, H2PO4-, Co2+ e Cu2+ mostraram interferência significativas (Er > 5 %) no método proposto. Concluindo a aplicação analítica do método, foi realizada determinação de ferro em produtos farmacêuticos e rochas naturais. Estudos comparativos dos resultados foram feitos utilizando também a absorção atômica como medidas paralelas. Na análise dessas amostras, o estudo comparativo entre a espectrofotometria e a absorção atômica apresentou resultados concordantes, não mostrando nenhuma interferência, visto que os erros percentuais obtidos acharem-se dentro do limite analítico comumente aceitável (< 5%). Os resultados obtidos mostraram a viabilidade e potencialidade do método espectrofotométrico proposto, como um método analítico alternativo para a determinação do ferro de maneira simples, precisa e exata. / One of the most traditional lines of work in the Chemistry is about the complex formation. In our laboratories this study is accomplished under a systematic way, principally involving pseudohalide and halide ligands with cations of transition metals. The intense color produced by the reactions among the pseudohalide ligands and metal have been so much explored by spectrophotometic analises. The strong red color characteristic of compounds formed between iron(III) and thiocyanate ions is one of the largest evidences of the analogy existent between the thiocyanate and azide(N3-) ligands. Studies done in our laboratories in the presence of some solvents and using iron-II ion have showed a fast oxidation of this metal followed by immediate reaction between the pseudohalide ligand and the metal. The possibilities of new methods for determination of the total amount of iron in a sample, as well as its speciation, have been analysed. During the study of the oxidation of the iron-II, several parameters that affect the oxidation speed in this system like: acidity, ligands concentration, temperature and presence of organic solvent, were verified carefully. This way, the recommended experimental conditions for a rapid oxidation and utilizing this system (determination of total iron) are: C H+= 30 mmolL-1 C SCN-= 250 mmolL-1 CAcetone = 70 % (v/v) T = 25ºC &#955;máx = 480nm waiting time = 7 minutes Calibration, stability, precision and diverse ions effect studies could be done using absorbances values for the ferric complexes that are measured at 480 nm. The analytical curve for the total iron determination, obeys the Beer law (r = 0,9993), showing potentiality for the analytical use of this system. The value of the average molar absortivity is 2,10.104 mol-1.L.cm-1. The ideal range of work for the determination of iron is from 1 to 8 ppm. A good precision was verified by suitable studies. About diverse ion effects, just the species NO2-, S2032-, C2042-, HPO42-, H2PO4-, Co2+ and Cu2+ showed some interference on determination in the proposed method. Concluding the analytical application of present method, determination of iron was tested in pharmaceutical product and natural rocks. Comparative studies of the results were made also using the atomic absorption as parallel measures. In these analysis samples, the comparative study between the spectrophotometric and atomic absorption presented concordant results, not evidencing significant interferences (errors commonly acceptable, <5%). The obtained results showed the viability and potentiality of the proposed method, as an alternative analytical manner for the determination of the metal with precision and exactness.
8

Scope and Mechanism of a Novel Base Induced Cyclization of Benzyl 1 Alkynyl Sulfones

Hossain, Mohammad Selim 20 November 2012 (has links)
Recent work has shown that sulfones are unique synthetic tools capable of undergoing numerous transformations and reactions. The sulfone group is a strong electron withdrawing group and has the ability to stabilize an α-sulfonyl carbanion. As such, unsaturated sulfones can undergo a variety of reactions, i.e. conjugate additions, alkylation etc. Beside this, α sulfonyl carbanion can be generated with strong base and α sulfonyl carbanion can also be used in various reactions. This report is an investigation of a novel base induced cyclization of various alkynyl sulfones. The results revealed that the reaction does not significantly depend on the electronic effects of substituents in the aromatic ring. Additional versatility in this process was demonstrated with respect to a diverse array of functionality at various positions i.e. benzylic position, aromatic ring and terminal position of alkyne. These alkynyl sulfones, bearing a larger group at ortho position and any group at benzylic position underwent intramolecular cyclization when treated with base affording benzothiopyran S,S-dioxide. The results demonstrated that the cyclization efficiency was significantly influenced by the steric effects of substituents of aromatic ring at ortho positions and blocking the terminal position with phenyl since the cyclization reaction gave low or no yields with aromatic rings having a substituent at para, meta or to position than those having no substituent. It was also found that 2-thiophenylmethyl sulfones cyclize more efficiently than benzyl and furfuryl sulfones. The evidence from mechanistic studies points to a mechanism for the cyclization that involves disruption of aromaticity. To disrupt aromaticity, a deprotonation at benzylic position is a requirement for this cyclization reaction. Results suggest that the cyclization also requires an available hydrogen at the point where the potential ring would be fused. Several intermediates were also observed spectroscopically and identified by ReactIR®.
9

The effect of ammonium thiocyanate in the application of direct dyes

Hester, Jimmie Morris January 1960 (has links)
No description available.
10

Rapid reactions kinetics of the formation of the ferric thiocyanate complex /

Below, John Frederick, January 1955 (has links)
Thesis (Ph. D. in Chemistry)--University of California, Berkeley, Jan. 1956. / Includes bibliographical references (p. 115-116). 46

Page generated in 0.0707 seconds