• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Magicads potential för ventilationssystem : - en studie om beräkningsprogrammets tillförlitlighet angående tryckfall i ett ventilationssystem med ett tilluft -och frånluftssystem

Pettersson, Martin January 2018 (has links)
Detta examensarbete är en del av energiingenjörsutbildningen i värmeteknik på Mälardalens högskola i Västerås och är en fördjupning inom ventilationsteknik. Arbetet har utförts med hjälp av företaget VentPartner i Västerås som har tillgodosett med det aktuella studerande ventilationssystemet. Syftet med detta examensarbete var att undersöka om beräkningsprogrammet MagiCAD är tillförlitligt med avseende på tryckfall i ventilationssystem samt vilken potential och påverkan programmet eventuellt kan ha för ventilationsbranschen. Tre stycken olika beräkningsmetoder för tryckfall har utförts; MagiCAD simuleringar, handberäkningar med formler och diagram samt fysiska mätningar med mätinstrument. Syftet har gått ut på att göra en jämförelse mellan dessa tre beräkningsmetoder för att med hjälp och tillsammans med tidigare forskning fastställa MagiCADs trovärdighet samt undersöka eventuella brister hos beräkningsprogrammet. Det studerade ventilationssystemet för den aktuella studien var ett till- och frånluftssystem på VentPartners kontor i Västerås. Systemet hade ett tilluftsflöde på 250 l/s och ett frånluftsflöde på 260 l/s. I arbetets tidiga skeende utfördes först ett platsbesök i syfte att ta fram referensdata av det utvalda ventilationssystemet. Med hjälp av stege, tumstock och en utskriven skiss av systemet samlade man in längd och dimensioner på kanaler, kanalernas placering i höjdled, produktinformation på don, spjäll och ljuddämpare. Därefter utfördes själva designen och uppritningen av ventilationssystemet i MagiCAD med hjälp av referensdata. När det projekterade ventilationssystemet var färdigt i MagiCAD utfördes själva tryckfallssimuleringen i beräkningsprogrammet. De manuella handberäkningarna utfördes med hjälp av formler och diagram och genomfördes i programmet Excel. De fysiska mätningarna utfördes vid ett separat platsbesök på VentPartners kontor och utfördes med universalmätaren Swema 3000 som Ventpartner tillgodosatte. Resultatet av tryckfallen ifrån MagiCAD simuleringarna och handberäkningarna skiljde sig endast en aning, både för tillufts -och frånluftssystemet. Medans tryckfallen ifrån de fysiska mätningarna skiljde sig betydligt mer jämförelsevis mot de andra två beräkningsmetoderna. Detta berodde på att MagiCAD och handberäkningarna utgår ifrån ideala förhållanden, vilket verkligheten aldrig är. Slutsatsen blev att beräkningsprogrammet MagiCAD är ett väldigt komplett och behagligt projekterings -och simuleringsprogram som är tillförlitligt. Dock har programmet sina brister i en del anpassningsfunktioner till verkligheten, men potentialen för framtiden ser ljus ut.
2

Att ta fram underlag för val av luftbehandlingssystem med återvinningssystem i Förvaltarens fastigheter / To provide data for the selection of HVAC systems with recycling systems in the Förvaltarens properties

Mohamed, Mahamud, Long, Xianyun January 2014 (has links)
Sverige och EU har man som mål att halvera energianvändningen fram till 2050 och det arbetet måste starta nu. Det är 15 miljoner kvm byggyta som måste halvera sin energianvändning varje år och i 40 år framåt. Redan idag är 70 % av alla hus till 2050 byggda, vilket innebär att även om vi skulle bygga passivhus fram tills dess skulle det inte räcka för att nå målet. Det är alltså en stor utmaning att halvera energianvändningen till 2050. En jämförelsestudie har genomförts mellan två värmeåtervinningssystem. Frånluftssystem med värmeåtervinning och från- och tilluftssystem med värmeåtervinning. Med hjälp av resultaten av genomförda projekt från två olika fastighetsägare har slutsatser kunnat dras. Slutsatserna är underlag till parametrar som påverkar valet av värmeåtervinningssystem. För att veta vad som är lämpligt har intervjuer genomförts med sakkunniga personer, fastighetsbolags energiansvariga, leverantörer samt konsulter.  Utifrån de intervjuer som genomfördes har uppfattning uppkommit om att alla har olika synpunkter och värderingar vid val av ventilationssystem samt att det är många faktorer som spelar roll vid val av ventilationssystem. I rapporten intervjuas två av Stockholms största fastighetsbolag: Stockholms Hem och Svenska Bostäder. Både fastighetsbolagen genomförde ett ”pilotprojekt” där man utfört prövning och utveckling av nya tekniska system. Syftet med pilotprojektet var att göra ett underlag för framtida projekt. De båda fastighetsbolagens val av ventilationssystem var situationsanpassade. Stockholms hem valde att använda sig av FX pga. affärsmässiga skäl samt utformningen av fastigheterna. Svenska Bostäder utförde större projekt där man totalrenoverade fastigheter, och därmed använde sig av FTX pga. klimatmässiga skäl. / Sweden has alongside with EU set a up goal to reduce the usage of energy with 50 % by 2050, a goal that Sweden to start working towards today/now. It is 15 million square meters of building space that needs to decrease its use of energy every year in 40 years. 70 % of all the buildings that are meant to be build in Sweden by 2050 are already made today, this strongly implicates that we will not be able to reach the goal even if the remaining 30% are strictly passive houses. It will be a demanding challenge to reduce the energy usage to half of its current state. A comparison has been made between two studies on waste heat recovery system, specifically the exhaust system with heat recovery and exhaust and supply air with heat recovery. A conclusion has be drawn from results of the two studies that were made. The conclusions are the main source for the parameters affecting the choice of waste heat recovery system. In order to know what was suitable for the goal, Interviews were made with experienced staffs, a property company, energy managers, contractors and consultants. Based on the interviews made, we concluded that all the parties had different views and standards when selecting a ventilation system, since there are many factors that play major roles in different areas. “Stockholms Hem” and “Svenska Bostäder” which is Two of Stockholm’s leading real estate companies were interviewed for this report. The two companies conducted a “pilot project” where they performed the investigation and development of new established technical systems. The pilot project was meant to be a base for future projects. The company’s choice of ventilation system was adapted after the situation. “Stockholms hem” chaose to use the an exhaust air heat pump due to business related reason and the design of the building, whereas “Svenska bostäder “ implemented major projects that renovated properties thus they chose an exhaust supply air heat exchange system due to climate reasons.
3

Självdrag eller FTX? : En jämförelse av ventilationssystem / Self-Exhaust Ventilation or Supply and Exhaust Ventilation ? : A Comparison of Ventilation Systems

Ali Mahmood, Chro, Yousefi, Leyla January 2023 (has links)
SammanfattningIntroduktion: Sedan år 2000 har antalet byggnader i Sverige ökat kraftigt. Enligt Statiska centralbyrån (SCB) fanns över 5 miljoner bostäder i Sverige i slutet av år 2021. Av dessa bostäder är cirka 42 % villor, 51 % flerbostadshus och resterande är lägenheter i specialbostäder. Energiförbrukningen i småhus har ökat med cirka 22% sedan 1970-talet, främst på grund av ökad användning av cirkulationspumpar, golvvärme och ventilation. Detta har resulterat i ökad miljöpåverkan från byggsektorn. Effektivisering av ventilationssystem har varit ett fokusområde under lång tid, eftersom användningsfasen av ventilationssystemen har visat sig ha hög energianvändning och stor miljöpåverkan. En studie visar att VVS-systemen påverkar miljön både vid tillverknings- och användningsfasen. Dessutom har nya lågenergihus en högre miljöpåverkan i byggfasen på grund av användningen av mer material för att minska driftanvändningen. Valet av ventilationssystem är avgörande för villor, eftersom ett effektivt ventilationssystem inte bara förbättrar inomhusluften utan också minskar risken för hälsoproblem som kan uppstå vid otillräcklig ventilation. Nyckelord: Livscykelkostnad, LCC, Ventilationssystem, Självdragssystem, FTX-system, VIP-Energy, Från- och tilluftssystem, Värmeåtervinning. Syfte: Syftet med examensarbetet är att visa att valet av ventilationssystem har betydelse för minskad klimatpåverkan vid tillverknings- och användningsfasen under 30 års tid. Mål: Målet är att ta fram vilket av självdragsventilation och från- och tilluftssystem med värmeåtervinning som är mest ekonomiskt och ger lägst klimatpåverkan baserat på ett livscykelperspektiv på ett småhus under en kalkylperiod på 30 år. Frågeställningar: Vilken av självdrag och FTX är mest effektivt med tanke på energiförbrukningen under tillverknings- och användningsfasen?Hur påverkar självdrag respektive FTX-systemet uppvärmningskostnaderna för ett småhus under förutsättning att uppvärmningen sker med fjärrvärme?Vilket av de två ventilationssystemen är mest ekonomisk lönsamt enligt en jämförande LCC, baserad på ett småhus med en kalkylperiod på 30 år?Vilket av ventilationssystemen orsakar störst klimatpåverkan? Metod: Metoden är en fallstudie där VIP-Energy används för att visa byggnadens energiförbrukning timme för timme under ett helt år. En LCC-beräkning utförs för att bestämma kostnaden för ventilationssystemet under dess livslängd, inklusive uppskattade underhållskostnader och nyinvesteringar. Slutsats: Baserat på energiförbrukningen under tillverknings- och användningsfasen är det mer effektivt att använda självdrag istället för ett FTX-system. Självdrag med vedeldning har ett lägre fjärrvärmebehov jämfört med FTX-systemet och ger därmed lägre årliga uppvärmningskostnader. Över en 30-årsperiod har självdragssystemet en lägre total livscykelkostnad än FTX-systemet. FTX-systemet har en högre elförbrukning och därmed en större påverkan på klimatet än självdragssystemet. / AbstractIntroduction: Since the year 2000, the number of buildings in Sweden has seen a significant increase. According to the Statistics Sweden (SCB), there were over 5 million dwellings in Sweden at the end of 2021. Out of these dwellings, approximately 42% are single-family houses, 51% are multi-family buildings, and the remaining is apartments in specialized housing. The energy consumption in single-family houses has increased by around 22% since the 1970’s, primarily due to the increased use of circulation pumps, underfloor heating, and ventilation. This has resulted in an increased environmental impact from the construction sector. Efficiency improvements in ventilation systems have been a longstanding focus due to the high energy consumption and significant environmental impact associated with their operational phase. A study reveals that HVAC systems impact the environment both during the manufacturing and the operational phases. Furthermore, new low-energy buildings have a higher environmental footprint during the construction phase due to the increased use of materials aimed at reducing operational energy consumption. The choice of a ventilation system is crucial for homes, as an efficient ventilation system not only improves indoor air quality but also reduces the risk of health problems that can arise from inadequate ventilation. Keywords: Life Cycle Cost, LCC, Ventilation System, Self-Exhaust Ventilation, Supply and Exhaust Ventilation, VIP-Energy, Supply and Exhaust Air System, Heat Recovery. Purpose: The purpose of the thesis is to demonstrate that the choice of ventilation system has a significant impact on reducing environmental emissions during the manufacturing and operational phases over a 30-year period. Goal: The objective is to determine which of self-exhaust ventilation and supply and exhaust ventilation with heat recovery is the most cost-effective and has the lowest climate impact based on a life-cycle perspective for a single-family building over a calculation period of 30 years.Questions: Which of self-exhaust ventilation and supply and exhaust ventilation is the most efficient in terms of energy consumption during the manufacturing and usage phases?How do self-exhaust ventilation and supply and exhaust ventilation affect the heating costs for a single-family building assuming that heating is provided through district heating?Which of the two ventilation systems is most economically viable according to a comparative Life Cycle Cost (LCC) analysis, based on a single-family building with a calculation period of 30 years?Which of the two ventilation systems causes the greatest climate impact?

Page generated in 0.0523 seconds