Spelling suggestions: "subject:"5issues 2analysis."" "subject:"5issues 3analysis.""
11 |
Análise de elementos traço presentes em tecidos mamários canino através da técnica de fluorescência de raios X / Analysis of trace elements present in canine breast tissue by fluorescence X-ray techniqueCozer, Thamara Cristina 30 March 2016 (has links)
CAPES / Estudos realizados com cães apontam que dos grupos tumorais analisados, os de mama representam cerca de 25% a 50% dos tipos de tumores. Deste total, metade é considerado maligno. Apesar de representar um valor considerável de malignidade, estudos nesta área são poucos representativos e escassos na literatura. É de conhecimento que os tumores são causados por mudanças químicas e bioquímicas que ocorrem na célula. Atualmente, pesquisas são realizadas para entender o comportamento dessas alterações e por este motivo é de grande valia conhecer os elementos traço presentes nestes tecidos. Para esta finalidade a técnica mais empregada é a de ED-XRF (Fluorescência de Raios X de Dispersão de Energia), uma vez que é uma técnica analítica não destrutiva que permite determinar e quantificar a composição elementar das amostras, porém não identifica elementos com baixos números atômicos (menor que Z=10). Foram analisadas 56 amostras de tecido mamário canino benignas e malignas, fixadas em formalina a 10% tamponada e mantida à temperatura ambiente. Primeiramente para a quantificação dos elementos traço Ca, Fe, Cu e Zn foram determinadas as curvas de calibração de padrões diluídos em água, com concentrações de Ca, Fe, Cu e Zn, variando de 400 mg/kg a 35 mg/kg, de 20 mg/kg a 2 mg/kg, de 10 mg/kg a 1 mg/kg e de 100 mg/kg a 9 mg/kg, respectivamente. As medições foram submetidas à técnica de ED-XRF utilizando um tubo de raios X com ânodo de prata e técnica de exposição de 30 kV e 100uA e um tempo de exposição de 1000 segundos (incerteza ≤ 3%). O código XRMC (X-Ray Monte Carlo) foi utilizado para validação do método experimental, que tem o objetivo de simular computacionalmente as respostas esperadas para os ensaios experimentais validando assim a eficácia da metodologia. As concentrações dos elementos traço obtidas foram analisadas estatisticamente onde verificou-se uma variação significativa do elemento Zn, estando este presente em maior concentração no tecido mamário maligno do que no benigno. Este resultado pode estar relacionado à presença deste elemento nas matrizes de metaloproteinases, e em neoplasias malignas estão mais concentradas porque há característica de invasão tumoral neste tipo de neoplasia. Em outra comparação estatística pode-se verificar que os elementos traços Fe, Cu e Zn tem concentração equivalente tanto na região central do tumor tanto quanto na periferia, com exceção do Ca, este concentrando-se mais na região tumoral o que pode se dever às calcificações. Estudos nessa área são de grande potencial por permitir um melhor entendimento do processo patológico em tumores mamários caninos. / Studies with dogs show that the breast cancer represent about 25% to 50% of tumor types. Of this total, half is considered malignant. Despite representing a considerable amount of malignancy, studies in this area are few representative and scarce in the literature. It is known that tumors are caused by chemical and biochemical changes that occur in the cell. Currently, surveys are conducted to understand the behavior of these changes and for this reason, it is of great value to know the trace elements present in these tissues. For this purpose, the most common technique is to ED-XRF (X-Ray Fluorescence Energy Dispersion) since it is a non-destructive analytical technique to determine and quantify the elemental composition of the samples, although it doesn’t identify elements with low atomic numbers (less than Z= 10). Were analyzed 56 samples of canine breast tissue benign and malignant, fixed in 10% buffered formalin and kept at ambient temperature. First, for the measurement of trace elements Ca, Fe, Cu and Zn were determined standards for calibration curves diluted in water to concentrations of Ca, Fe, Cu and Zn, ranging from 400 mg/kg to 35 mg/kg, from 20 mg/kg to 2 mg/kg, from 10 mg/kg to 1 mg/kg and from 100 mg/kg to 9 mg/kg, respectively. Measurements were subjected to ED-XRF technique using an X-ray tube with silver anode and exposure technique of 30 kV and 100 uA and exposure time of 1000 seconds (uncertainty ≤ 3%). The XRMC code (X-Ray Monte Carlo) was used for validation of experimental method, which is intended to simulate by computer the expected responses for experimental tests, therefore validating the methodology efficiency. The concentrations of trace elements obtained were analyzed statistically where there was a significant variation of Zn element, the latter being present in higher concentration in malignant breast tissue than benign. This result may be related to the presence of this element in the matrix metalloproteinases, and malignant neoplasms are more concentrated because there are characteristic of tumor invasion in this type of neoplasm. In another statistical comparison it can be seen that the trace elements Fe, Cu and Zn is equivalent concentration both in the central region of the tumor as well as in the periphery, with the exception of Ca, this focusing more on the tumor region may be due to calcifications. Studies in this area are of great potential for allowing a better understanding of the disease process in canine mammary tumors.
|
12 |
Estudo da aplicação da técnica de ED-XRF para caracterização elementar de tecidos mamáriosCastilho, Priscila Resmer 27 August 2014 (has links)
CAPES / O câncer de mama deve atingir cerca de 57.120 novos pacientes no Brasil em 2014, como divulgado pelo serviço de epidemiologia do Instituto Nacional de Câncer. Pesquisadores têm associado neoplasias mamárias às alterações nas concentrações de alguns elementos no tecido da mama, tais como: cálcio, ferro, cobre e zinco. Neste sentido a técnica de espectroscopia por fluorescência de raios X surge como uma ferramenta para caracterização elementar deste tipo de tecido. A eficácia da referida técnica é fortemente dependente do espectro de raios X incidente na amostra, bem como do procedimento de calibração do sistema de medição. Neste trabalho foi avaliada a influência dos filtros de alumínio na eficiência de medição das concentrações dos elementos atrelados à neoplasias mamárias e avaliação das concentrações mínimas que o equipamento do Laboratório de Física Nuclear Aplicada da Universidade Tecnológica Federal do Paraná é capaz de registrar. O equipamento sobe investigação foi o da Amptek composto por um kit de um tubo de raios X modelo Mini-X e um detector do modelo X-123SD. Dos resultados, observou-se que para a quantificação dos referidos elementos simultaneamente, o uso de filtros de Al com espessura de 0,25 mm proporciona melhor eficácia na excitação dos mesmos. Além disso, foi verificado que são necessárias curvas de calibração específicas para cada elemento, as quais foram obtidas com cinco padrões biológicos da Agência Internacional de Energia Atômica. Os resultados permitiram comparar as concentrações dos padrões certificados aos obtidos pelos cálculos, assim como quantificar duas amostras de tecido mamário de características neoplásicas. / Breast cancer can reach around 57.120 new cases in Brazil in 2014, according the service of epidemiology in the National Cancer Institute. Researchers have been associated mammary neoplasm with changes of elements concentrations such as: calcium, iron, copper and zinc. In this way the technique of X-Ray Fluorescence appears like a tool to characterize this kind of neoplasm. The effectiveness of this technique is strongly dependent of X-ray spectrum incident on the sample as well as the calibration procedure of the measuring system. In present work, were evaluated the influence of aluminum filters on the measurement efficiency of the concentrations of the elements changed in mammary neoplasm and to evaluate the minimum concentrations that the equipment of the Laboratory of Applied Nuclear Physics at Federal University of Technology – Paraná is capable to register. The equipment under study was the Amptek kit of X-ray tube Mini-X and detector X-123SDD. The results obtained shown a simultaneous analysis, in that Al filters with thicknesses of 0.25 mm provides the best efficiency. Besides, it was verified that specifics calibration curves for each element was required, and it were obtained with five biological standards of International Atomic Energy Agency. The results made possible to compare the concentration of biological standards certificates with the equation obtained, in addition to analyze quantitatively two sample of breast tissue.
|
Page generated in 0.0379 seconds