• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Estudo comparativo entre as tomografias computadorizadas 3D, ortopantomográficas e radiografias periapicais no diagnóstico de lesões periapicais, fraturas radiculares e reabsorções dentais / Comparative study between 3D computed tomography, orthopantomography and periapical radiography for diagnosis of periapical lesions, root fractures and tooth resorptions

Ricardo Affonso Bernardes 19 November 2007 (has links)
O pilar do sucesso do tratamento endodôntico é o diagnóstico e, para esse objetivo, a radiografia é um excelente recurso auxiliar, tanto pelo seu custo, como pela facilidade de obtenção. Contudo, ela tem suas limitações, pois trata-se da imagem bidimensional de um objeto tridimensional e daí a dificuldade encontrada no diagnóstico de lesões periapicais, fraturas radiculares e reabsorções dentais. Com o advento e o uso da tomografia computadorizada (TC), a partir de 1972, houve uma melhora na capacidade diagnóstica, com as imagens tridimensionais. Entretanto, a TC helicoidal tem limitações, na Odontologia, pelo seu custo, alta dose de radiação à qual o paciente é submetido pela presença de artefatos metálicos. Com a introdução da tomografia computadorizada na Odontologia, por meio do sistema de aquisição Cone Beam, essas desvantagens foram minimizadas, ocorrendo o aumento da qualidade diagnóstica da imagem tridimensional. O objetivo deste trabalho foi comparar a capacidade diagnóstica da tomografia computadorizada Cone Beam, utilizando o aparelho Accuitomo 3DX com as radiografias periapicais e ortopantomográficas (panorâmicas), em casos de lesões periapicais, fraturas radiculares e reabsorções dentais. Para isso, foram analisadas imagens obtidas por meio da tomografia e pelas técnicas radiográficas periapical e panorâmica de 150 casos clínicos, por dois examinadores calibrados, usando escores préestabelecidos. Os resultados permitiram afirmar que a técnica da tomografia apresentou diferença estatisticamente significante em relação às demais técnicas, no diagnóstico da extensão e localização de lesões periapicais, fraturas radiculares e reabsorções dentais. / Diagnosis is the basis of success of endodontic treatment; radiography is an excellent aid for that purpose, due to both cost and easy achievement. However, it also has limitations, since it is a bidimensional image of a three-dimensional object; this explains the difficulty in the diagnosis of periapical lesions, root fractures and tooth resorptions. The advent and use of computerized tomography (CT) since 1972 improved the diagnostic ability with utilization of three-dimensional images. However, helical CT is limited in Dentistry, due to its cost, high radiation dose and presence of metallic artifacts. These disadvantages were minimized by introduction of the cone beam system in dentistry, which improved the diagnostic quality of three-dimensional images. This study evaluated the diagnostic ability of cone beam computerized tomography using the appliance Accuitomo 3DX, compared to periapical and panoramic radiographs, in cases of periapical lesions, root fractures and tooth resorptions. Images of 150 clinical cases were obtained by tomography and by periapical and panoramic radiographic techniques and evaluated by two calibrated examiners, using pre-established scores. The results revealed that the tomography technique presented statistically significant difference in relation to the other techniques for diagnosis of the extent and location of periapical lesions, root fractures and tooth resorptions.
142

Tomografia computadorizada aplicada a estudos de compactação de solos / Computed tomography scanner applied to soil compaction studies

Carlos Manoel Pedro Vaz 06 December 1989 (has links)
O presente trabalho estuda a compactação do solo, do ponto de vista da mecânica do solo, isto é, medindo as deformações causadas por forças agindo neste. O equipamento utilizado é um tomógrafo computadorizado de primeira geração que fornece imagens, por transmissão de radiação, de seções transversais de amostras de solo (até aproximadamente 10 cm na configuração utilizada), com precisão de milímetros. Esta imagem é uma matriz de coeficientes de atenuação linear, os quais podem ser correlacionados com a densidade do solo através de uma calibração para cada solo. O trabalho se divide nos seguintes experimentos: a) experimentos básicos de calibração e resolução do equipamento; b) medidas de finas camadas de solo compactado; c) experimentos de transmissão de pressões no solo por implementos agrícolas; d) modelamento pressão-deformação em amostras de solo confinadas, com vários graus de umidade; e) levantamentos de perfis de densidade, com amostras retiradas numa trincheira, comparando com a técnica de penetrômetro. De um modo geral, os resultados evidenciaram um erro de medida da densidade e umidade entre 2 e 3% para uma dada imagem, com resolução espacial da imagem igual a 2 mm. No estudo de finas camadas de solo compactado, foi possível a quantificação de camadas compactadas maiores que 2 mm. Em experimentos de campo, após a passagem de um sulcador num Latossol Vermelho Escuro, para várias condições de densidade, umidade e peso do implemento, foram obtidos resultados desde praticamente nenhum aumento de densidade no perfil da amostra, até 0,08 g/cm3 da superfície de contato solo-implemento para baixo. No experimento com amostras coletadas numa trincheira foi obtida a caracterização de um perfil de densidade com resolução espacial igual a 2 mm, indicando existência de uma região compactada de 30 cm, com densidade de 1,3 a 1,5 g/cm3. Sondagens com o penetrômetro indicaram uma grande dependência deste com a umidade do solo. Sendo que para solo seco, o perfil do penetrômetro se assemelha muito com o perfil de densidade obtido com o TC. No estudo de modelamento pressão-deformação em amostras confinadas, obteve-se uma correlação linear da densidade com a distância da amostra, para uma carga 0,8 mPa, numa dada umidade. Por fim, conclui-se que a TC pode ser utilizada na maioria dos problemas de compactação do solo, com desempenho superior às técnicas tradicionais, tanto em problemas de modelamento pressão-deformação como em problemas de campo. / The soil compaction problem was studied using a first generation computed tomography scanner (CT). This apparatus gets images of soil cross sections samples, with resolution of a few millimeters. We performed the following laboratory and field experiments: a) Basic experiments of equipment calibrations and resolutions studies. b) Measurements of compacted soil thin layers. c) Measurements of soil compaction caused by agricultural tools. d) Stress-strain modelling in confined soil sample, with several moisture degree. e) Characterizations of soil bulk density profile with samples collected in a hole (trench), comparing with a cone penetrometer technique. The results showed errors in soil bulk density and moisture content around 2% and 3%, for an image with 2 mm of spatial resolution. In compacted soil thin layer studies, was possible identified layers grater than 2 mm. Experiments of compacted soil caused by agricultural tools provided results since zero up to 0.08 g/cm3 of soil bulk density increase, in the sample profile. In the experiment with samples collected in a trench, the results shown a compacted region of 30 cm between 1,3 to 1,5 g/cm3. Measurement with cone penetrometer showed a close dependence with soil moisture content. For dry soils, the cone penetrometer profile was very similar to the soil bulk density measured by CT. Stress-strain modelling studies with confined samples, provided an approximatly linear correlation between soil bulk density and sample length, for 0,8 MPa pressure, for a constant moisture content. Finally, we concluded that the CT can be used in the study of soil compaction problems, with better performance than be traditional techniques.
143

Um método D-bar para estimar admitividade em 2-D através de tomografia por impedância elétrica. / A D-bar method for recovering admittivity in 2-D electrical impedance tomography.

Claudia Natalia Lara Herrera 23 August 2012 (has links)
Propõe-se um novo método D-bar de Tomografia por Impedância Elétrica (TIE) para obter, simultaneamente, a condutividade e a permitividade de um domínio 2-D. O algoritmo direto baseia-se na prova de existência e unicidade do artigo de E. Francini [1]. A caracterização de tecidos biológicos é fortemente facilitada a partir do conhecimento de suas propriedades elétricas. Particularmente, nas aplicações médicas de TIE há grande interesse na permitividade, uma vez que, vários autores tem apresentado critérios para distinguir patologias baseados nesta propriedade, um exemplo constitui a determinação de presença ou ausência de sangue em líquidos acumulados no pulmão. Realizam-se testes com dados simulados numericamente e experimentais com o propósito de verificar e entender as propriedades, capacidades e limitações do algoritmo implementado. No caso dos testes numéricos, é desenvolvido um programa que resolve o problema direto da admitividade, o qual permite calcular conjuntos de dados de voltagem numéricos. São simulados dados aplicando padrões de corrente trigonométricos e por pares. As soluções exponencialmente crescentes do problema inverso são parte essencial do algoritmo e devem ser decompostas nas bases dos padrões de injeção de corrente. A compreensão da natureza destas decomposições para padrões de injeção trigonométricos e por pares, levou ao estabelecimento de especificações no projeto de um sistema de TIE para este algoritmo. Os resultados encorajadores numéricos e experimentais obtidos nas reconstruções de condutividade e permitividade, quanto à resolução espacial e às magnitudes, indicam que o algoritmo é promissor para uso clínico. / This work proposes a new D-bar method of Electrical Impedance Tomography (EIT) for reconstructing the conductivity and permittivity simultaneously in a 2-D domain. The direct algorithm presented is based on the existence and uniqueness proof by E. Francini [1]. Biological tissue characterization is strongly facilitated by the knowledge of its electric properties. In EIT medical applications there is great interest in the permittivity as an additional property for distinguishing pathologies. For instance, the determination of presence or absence of blood in fluid accumulation in the lung. Numerical and experimental data tests are carried out in order to verify and understand the properties, capabilities and limitations of the implemented algorithm. A numerical phantom to solve the forward admittivity problem is developed which allows to simulate voltage data sets. Trigonometric and pairwise injection current patterns are applied. Exponentially growing solutions of the inverse problem are a key part of the algorithm, which have to be expanded in terms of the current patterns. Understanding the nature of these expansions for trigonometric and pairwise injection current patterns leads to a set of specifications in the design of an EIT system for this algorithm. The encouraging numerical and experimental results obtained in conductivity and permittivity reconstructions, regarding the magnitude and spatial resolution, indicate that the algorithm is promising for clinical use.
144

Reconstrução não-linear completa de imagens de tomografia por impedância elétrica utilizando o método D-bar 2D. / Reconstruction nonlinear full of images of electrical impedance tomography using the 2D D-bar method.

Miguel Fernando Montoya Vallejo 16 October 2012 (has links)
Neste trabalho desenvolveu-se desenvolver uma versão sem linearizações do método D-bar para Tomografia por Impedância Elétrica (TIE). O problema inverso de TIE é não-linear e mal-posto. O algoritmo baseia-se na prova de existência e unicidade de Adrian Nachman [Ann. of Math. 143 (1996)] para domínios com distribuição de condutividade duas vezes diferenciáveis. O método faz uso de uma Transformada de Fourier não-linear chamada scattering transform, e o caráter mal-posto do Problema Inverso torna-se evidente no cálculo desta transformada, mais especificamente na determinação das soluções Complex Geometrical Optics (CGO). Atuais implementações práticas do método D-bar para padrões trigonométricos tem aproximado os valores na fronteira das soluções CGO por seu comportamento assintótico no cálculo da scattering transform, o que constitue uma linearização nesta etapa específica do método. Neste trabalho calcula-se a scattering transform a partir das soluções exponencialmente crescentes, o que implica calcular as funções Green de Faddeev, com o objetivo de encontrar imagens com maior resolução espacial e precisão nos valores de condutividade por ter resolvido o problema não-linear de forma completa. Dados de simulação numérica e experimentais usando padrões de injeção pula eletrodos e trigonométricos foram usados na avaliação do método. As imagens obtidas apresentam comportamento diferente em função do padrão de injeção utilizado. Do cálculo completo da transformada scattering resultam imagens com melhor resolução espacial. As imagens reconstruídas a partir de padrões de injeção trigonométricos apresentam também melhor resolução espacial comparadas as imagens reconstruídas a partir de padrões por pares, separados por três eletrodos. / This work proposes to develop a version of the D-bar method linearization for Electrical Impedance Tomography (EIT). The inverse problem of EIT is both nonlinear and very ill-posed. The version of the D-bar method implemented here is based on the existence and uniqueness proof of Adrian Nachman [Ann. of Math. 143 (1996)]. The method relies on the use of a nonlinear Fourier transform called the scattering transform, and the inherent ill-posedness of the inverse conductivity problem becomes evident in the computation of the scattering transform, more specifically in the determination of the Complex Geometrical Optics (CGO) solutions. Current practical implementations of the D-bar method using trigonometric patterns have replaced the boundary values of the CGO solutions by their asymptotic behavior in the calculation of the scattering transform, which is a linearization in this particular step of the overall method. This work proposes to calculate the scattering transform from exponentially growing solutions, which implies the calculation of the Faddeev Greens function, with the goal of obtaining images with higher resolution and accuracy in the conductivity values because the full nonlinear problem is solved. Numerical and experimental data using pairwise and trigonometric current injection patterns were used to evaluate the performance of the method. Better spatial resolution is obtained from the complete computation of the scattering transform. Reconstructed images from trigonometric current patterns also show better spatial resolution compared to pairwise current injection patterns, skipping three electrodes.
145

Avaliação da prescrição de tomografias computadorizadas por feixe cônico em universidade pública

Maria Cecilia Sinatura Barros 30 October 2012 (has links)
Durante o século passado, o diagnóstico por imagem na odontologia, foi dominado por radiografias, que são representações bidimensionais de estruturas tridimensionais, com sobreposição e distorções associadas. Com a introdução da tomografia computadorizada cone-beam (TCCB), houve um aumento no interesse por esta tecnologia dado às vantagens, como melhor qualidade de imagem, reconstrução tridimensional, possibilidade de visualização craniofacial, e as doses de radiação mais baixas em comparação com a tomografia computadorizada convencional (TC). A TCCB pode ser aplicada em diversas áreas da Odontologia, tais como: implantodontia, cirurgia, traumatologia, periodontia, endodontia, ortodontia, articulações temporomandibulares. Contudo, os profissionais da saúde devem estar cientes que os avanços tecnológicos terão implicações importantes sobre a prática clínica. Estes mesmos profissionais devem conhecer as indicações, limitações e implicações antes de considerar a utilização de tal equipamento. Sendo assim, o presente estudo pretende analisar, criticamente, a utilização e indicação do exame de imagem TCCB na Faculdade de Odontologia de Bauru USP. Ao mesmo tempo, pretende avaliar quantitativamente o uso deste equipamento em relação ao motivo da solicitação e a área bucal requisitada. / During the past century, the diagnostic for image in the dentistry, was dominated for radiographies, which are bidimensional representation of the tridimensional structure with superposition and distortion associated. With the introduction of cone-beam computed tomography (TCCB), there was an increased interest in this technology due to advantages such as better image quality, three-dimensional reconstruction, ability of craniofacial visualization and lower radiation doses compared with the conventional computed tomography (CT). The TCCB can be applied in various areas of dentistry such as dental implants, surgery, traumatology, periodontics, endodontics, orthodontics, temporomandibular joints. However, health professionals should be aware that technological advances have important implications for clinical practice. These same professionals should know the indications, limitations and implications before considering the use of such equipment. Thus, this study aims to analyze critically the use and indication of imaging examination TCCB in the Bauru Dental School - USP. At the same time, evaluate quantitatively the use of equipment for the purpose of the request.
146

Estudo anatômico e morfométrico da orelha interna da ovelha : através da tomografia computadorizada

Seibel, Valter Alberto Ayres January 2004 (has links)
INTRODUÇÃO: Os trabalhos sobre o uso de ovelhas para cirurgia experimental e treinamento em cirurgia otológica são raros. O presente trabalho estuda a orelha interna da ovelha por meio de tomografia computadorizada e cortes sucessivos de 0,5 mm, no sentido de apresentar dados morfométricos mais precisos relacionados à comparação entre a orelha de ovelhas e a orelha humana. MATERIAIS e MÉTODO: Foi realizado um estudo descritivo sem seguimento no qual foram comparadas as estruturas da orelha interna da ovelha com as dos humanos. Medidas da orelha interna da ovelha e também da orelha interna humana foram obtidas através de tomografias computadorizadas. As medidas foram armazenadas em unidade de disco compacto no padrão DICOM para posterior análise e manipulação em um programa específico de análise de imagens médicas denominado Osíris 4.16. Neste programa, as imagens foram avaliadas quanto às dimensões de determinadas estruturas, utilizando-se recursos de reconstruções multiplanares, os quais permitiram a realização de medidas nos três eixos: sagital, coronal e axial. As medidas foram tabuladas e posteriormente analisadas pelo programa de planilha de dados e análise estatística Microsoft Excel. Foi calculado um tamanho de amostra mínimo de 36 orelhas ovinas para 12 orelhas humanas. RESULTADOS: O estudo morfológico da orelha da ovelha em média e da orelha humana em média revelaram respectivamente que o vestíbulo apresenta 2,4 mm e 2,9 mm de largura, 4,1 mm e 6,8 mm de comprimento e 3,8 mm e 4,3 mm de altura. O comprimento do modíolo ou columela é de 3,4 mm e 5,9 mm. O diâmetro do giro basal externo da cóclea mede 8,2 mm e 9,1 mm e o diâmetro do giro basal interno da cóclea mede 4,9 mm e 6,4 mm. O diâmetro do giro médio externo da cóclea mede 7,1 mm e 6,9 mm e o diâmetro do giro médio interno da cóclea mede 3,7 mm e 4,4 mm. O diâmetro do giro do ápice externo da cóclea mede 6,2 mm e 6,2 mm e o diâmetro do giro do ápice interno da cóclea mede 3,0 mm e 3,5 mm. O raio do canal do giro basal interno da cóclea mede 1,3 mm e 2,1 mm. O promontório em sua espessura mede 1,4 mm e 1,3 mm. O canal ósseo da cóclea mede 19,9 mm e 26,8 mm de comprimento. O meato auditivo interno em seu diâmetro mede 1,6 mm e 5,2 mm e em seu comprimento mede 2,0 mm e 13,0 mm. CONCLUSÃO: Há grande similaridade entre a anatomia da orelha interna da ovelha e a da orelha interna humana nas mensurações realizadas. A maior parte das estruturas estudadas (10 de 15) preservou a relação proposta de 2/3 da dimensão humana em relação à dimensão ovina. Há uma grande contribuição na morfometria para a ovelha como modelo em cirurgia experimental e treinamento em cirurgia otológica.
147

Avaliação tomográfica da orelha contralateral de pacientes com otite média crônica severa / CT scan of the contralateral ear in patients with severe chronic otitis media

Silva, Maurício Noschang Lopes da January 2012 (has links)
Introdução: Alguns estudos apontam para uma tendência à bilateralidade da otite média crônica. Acredita-se que a orelha contralateral possa fornecer indícios da via de formação da doença na orelha principal (a mais acometida), ser um parâmetro da função tubária e predizer o sucesso terapêutico. A tomografia computadorizada é um excelente exame para avaliar as estruturas do osso temporal e as alterações decorrentes de otite média. Objetivo: Avaliar tomografias computadorizadas de orelhas de pacientes com otite média crônica e aferir a prevalência de alterações nas orelhas contralaterais. Métodos: Estudo transversal. Avaliação das tomografias de 75 pacientes do Ambulatório de Otite Média Crônica do Hospital de Clínicas de Porto Alegre por um neurorradiologista. Resultados: a população foi constituída de 50,6% do gênero masculino com média de idade de 36 anos. Encontramos 48% de alterações nas membranas timpânicas das orelhas contralaterais. Quanto à cadeia ossicular, houve 9,3% de alterações nos martelos, 10,7% nas bigornas e 25,3% nos estribos. Na mastóide, 28% dos antros estavam velados. Conclusões: A prevalência de alterações radiológicas nas orelhas contralaterais de pacientes com otite média crônica corrobora com achados de estudos clínicos, funcionais e histopatológicos prévios de que a doença tem caráter bilateral. / Introduction: Some studies indicate a bilateral tendency of chronic otitis media. It is believed that the contralateral ear (CLE) can provide evidences of the route of formation of ear disease in the major (most affected), be a parameter of Eustachian tube function and predict successful treatment. The CT scan is an excellent test to evaluate the structures of the temporal bone and the changes resulting from otitis media. Objective: To evaluate Temporal Bone Computed Tomography of patients with chronic otitis media and describe changes in the contralateral ear. Methods: Cross-sectional study. Evaluation of CT scans of 75 patients with chronic otitis media from Clinicas Hospital of Porto Alegre by a neuroradiologist. Results: Population was consisted of 50.6% males with a mean age of 36 years. We found 48% of changes in the tympanic membranes of the contralateral ears. About ossicular chain, there was 9.3% of changes in malleus, 10.7% in incus and 25.3% in stapes. Mastoid antrum were veiled on 28%. Conclusions: The prevalence of radiographic changes in the contralateral ears of patients with chronic otitis media corroborates with clinical, histopathological and functional resources that this disease has a bilateral feature.
148

Avaliação do desempenho da tomografia computadorizada helicoidal no diagnóstico de pólipos colorretais : estudo clínico

Pfeifer, Gustavo Kuhn January 2001 (has links)
O câncer colorretal é a segunda neoplasia maligna mais prevalente nos países desenvolvidos. O Rio Grande do Sul apresentou as mais elevadas taxas de incidência e mortalidade dessa doença no Brasil no ano 2000 segundo o Instituto Nacional de Câncer. Esse câncer pode ser prevenido se as lesões precursoras, os adenomas, forem diagnosticados e removidos precocemente. Vários centros estão agora explorando o emprego da tomografia computadorizada helicoidal (TC colonografia) no diagnóstico dos pólipos colorretais. Este estudo avaliou o desempenho desse teste radiológico na detecção dessas lesões, utilizando a colonoscopia como padrão-ouro. Foram estudados, de modo prospectivo, 20 pacientes com risco acentuado para neoplasia colorretal (14 homens e seis mulheres). A colonoscopia, realizada após a TC colonografia, diagnosticou 85 pólipos em 19 pacientes. O exame radiológico detectou oito dos 10 pólipos com diâmetro igual ou maior do que 10mm (80%), dois dos 21 iguais ou maiores do que cinco e menores do que 10mm (10%), e um dos 54 pólipos menores do que cinco milímetros (2%). Dois resultados falso-positivos ocorreram em um mesmo paciente. A TC colonografia apresentou sensibilidade de 53%, RESUMO xv especificidade de 100%, valor preditivo positivo de 100% e valor preditivo negativo de 10%. Dezenove pacientes prefeririam ser submetidos à outra colonoscopia na eventualidade de ter que repetir um dos dois exames. Na detecção de pólipos colorretais, a TC colonografia parece útil apenas quando resulta positiva, não servindo para afastar a existência dessas lesões. / Colorectal cancer is the second most common malignancy in developed countries. According to Instituto Nacional de Cancer, in 2000 the state of Rio Grande do Sul presented the highest incidence and mortality rates from this disease in Brazil. This cancer can be prevented if the precursor lesions, the adenomas, are diagnosed and removed early. Many centers are now exploring the use of CT colonography for the diagnosis of colorectal polyps. This study assessed the performance of this radiological method in detecting these lesions, using colonoscopy as the gold standard. Twenty patients (14 men and 6 women) with a high risk for colorectal neoplasia were studied prospectively. Colonoscopy, carried out after CT colonography, diagnosed 85 polyps in 19 patients. The radiological examination identified 8 of the 10 polyps that were 10mm or greater (80%), two of the 21 polyps equal to or greater than 5mm but smaller than 10mm (10%), and one of the 54 polyps smaller than 5mm (2%). Two false positive results were found in a same patient. The sensitivity and specificity per patient of CT colonography for all lesions were 53% and 100% respectively, and the positive predicitive value and negative predictive value were 100% and 10% respectively. Nineteen patients preferred colonoscopy in the event of having to repeat one of the two examinations. For the detection of colorectal polyps, CT colonography seems to be useful only when the result is positive, as the negative results of this examination cannot eliminate the presence of these lesions.
149

Avaliação do Esmalte Dentário Após a Descolagem de Brackets Ortodônticos e da Remoção da Resina Remanescente

Lopes, Mônica Schäffer 08 August 2012 (has links)
Submitted by Lucelia Lucena (lucelia.lucena@ufpe.br) on 2015-03-13T18:08:55Z No. of bitstreams: 2 DISSERTAÇÃO MESTRADO MONICA SCHAFFER.pdf: 1718738 bytes, checksum: 96f6f213957ec36cb4878c8cabad2599 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-13T18:08:55Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO MESTRADO MONICA SCHAFFER.pdf: 1718738 bytes, checksum: 96f6f213957ec36cb4878c8cabad2599 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-08-08 / Objetivos: No presente trabalho foi objetivo avaliar a superfície do esmalte após a descolagem de brackets ortodônticos e remoção da resina remanescente, por meio da técnica da Tomografia por Coerência Óptica (TCO), em 2D e 3D. Materiais e Métodos: Sessenta coroas de incisivos bovinos foram incluídas em resina acrílica, com auxílio de matriz metálica, e em seguida submetidas a polimento manual com lixas d’água com granulações crescentes. A colagem do bracket foi realizada com o sistema TransbondTM XT (3M), e o armazenamento das amostras, em ambiente úmido por 1 semana. No artigo 1, vinte dentes foram divididos (n=10) em grupo A, descolagem com alicate 346/ICE e B, descolagem com pistola 346/Zatty. Foram feitas imagens das amostras em Microscópio Óptico (MO) e TCO 3D, e três avaliadores as classificaram quanto o Índice de Adesivo Remanescente (IAR), que posteriormente foi calculado pelo Teste de Kappa. As imagens em TCO 2D serviram para calcular a espessura do ARI e perda de esmalte. No artigo 2, quarenta dentes foram descolados com alicate 346/ICE e sem seguida divididos (n=10) em G1, remoção da resina remanescente com broca carbide de tungstênio (BCT) 30 laminas em alta rotação + pasta diamantada e disco de feltro/Diamond; G2,Pontas de fibra de vidro em baixa rotação/TDV; G3,Laser Er:YAG 100 mJ/1.00 W e G4,BCT 30 laminas + polimento com discos de óxido de alumínio/Dhpro. Medidas de rugosidade foram tomadas antes e depois da remoção, bem como imagens em TCO 2D,3D e Microscópio Eletrônico de Varredura (MEV). Foi usado teste estatítisco ANOVA. Resultados: O MO e TCO 3D apresentaram 0,83% e 0,70% de concordância no teste de Kappa, respectivamente. Através do TCO 2D, observou-se espessura da resina residual após descolagem do bracket, em torno de 164μm (±34 μm). Resultados do IAR mostraram 72,7% em score 3 e 27,3% em score 2 no grupo A; e 55,6% em score 1, 33,3% em score 2 e 11,1% em score 3, no grupo B. G1, G3 e G4 tiverem rugosidades finais similares, diferente do G2 que apresentou aumento significante (p<0.05). Análises da superfície mostraram ranhuras horizontais e verticais no G1 e G4, áreas pontuais de perda mineral no G3. Conclusões: MO e TCO 3D foram considerados satisfatórios para mensurar o IAR. TCO 2D foi preciso para medir a espessura de resina remanescente. O grupo do alicate (A) apresentou fratura predominantemente na interface bracket/adesivo que preserva mais estrutura de esmalte que o grupo da pistola (B) que a fratura ocorreu frequentemente na interface esmalte/adesivo. A remoção da resina remanescente apresenta influencia direta na rugosidade final. Nenhum método de remoção foi considerado perfeito. Laser Er:YAG produziu a maior perda mineral, e a ponta de fibra de vidro não foi capaz de promover um polimento adequado, apresentando a maior rugosidade final. Todos os 3 métodos de avaliação da superfície foram considerados bons para mensurar a perda de esmalte, entretanto, o TCO apresenta a possibilidade de ser aplicada clinicamente.
150

Avaliação da interface faceta-cimento-esmalte por tomografia por coerência óptica

DIAS, Tereza Januária Costa 21 February 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-27T21:58:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Tereza Januária Costa Dias.pdf: 1240496 bytes, checksum: fc2abe6f690c5ae57559b6627fa606f1 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-05T21:16:11Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Tereza Januária Costa Dias.pdf: 1240496 bytes, checksum: fc2abe6f690c5ae57559b6627fa606f1 (MD5) / Made available in DSpace on 2018-09-05T21:16:11Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Tereza Januária Costa Dias.pdf: 1240496 bytes, checksum: fc2abe6f690c5ae57559b6627fa606f1 (MD5) Previous issue date: 2017-02-21 / O objetivo deste trabalho foi a avaliação da interface de cimentação de micro laminados cerâmicos por tomografia por coerência óptica (OCT), cimentados com diferentes cimentos resinoso (RBC), através da técnica convencional cimentação ou utilizando o dispositivo de vibração sônica (SV) antes da reação de cura do cimento. Os laminados foram preparados à base de IPS e.max (Ivoclar-Vivadent), onde blocos de esmalte bovino foram preparados e divididos aleatoriamente em seis grupos (n = 5) de acordo com os RBC utilizados: All Cem Veneer (FGM Dentscare), ACC/ ACSV; NX3 (Kerr), NX3C/ NX3SV; and RelyX Veneer (3M ESPE), RVC/ RVSV. Os grupos ACC / NX3C / RVC foi submetido à cimentação convencional (C), enquanto que o ACSV / NX3SV / RVSV recebeu o Smart Sonic Device (SSD, FGM Denstcare) operando a 170 Hz antes da reação de cura. A análise de OCT foi realizada antes da aplicação de RBC, 48h após a cimentação e 48h após a ciclagem térmica. O sistema OCT (Ganymede SD-OCT, Thorlabs) opera a 930 nm de comprimento de onda central, taxa de varredura axial de 29 kHz, resolução lateral de 8 μm e resolução axial de 5,8 μm / 4,4 μm no ar / água, respectivamente. Um algoritmo foi desenvolvido em MATLAB para redução de ruído e extraídos o A-scan das imagens filtradas para análise. Histogramas foram extraídos de amostras através do software Image J, onde os tons de cinza foram avaliados. As falhas foram visualizadas em imagens bidimensionais de OCT e confirmadas pelos A-scans. Os testes T-student e Anova foram utilizados quando os casos de normalidade foram indicados. Mann-Whitney e Kruskall-Wallis, quando a normalidade não foi observada. As falhas foram claramente visualizadas em imagens OCT e confirmadas por A-scans. Não houve diferença estatística entre a técnica convencional e o uso da técnica SVD para evitar falhas. Além disso, após o ciclo térmico, apenas RVSV apresentou resultados estatisticamente diferentes em relação aos outros grupos. / To evaluate using optical coherence tomography (OCT) ceramic veneers interface with different resin-based cements (RBC), through conventional technique or using sonic vibration device (SV) before RBC cure reaction. IPS e.max (Ivoclar-Vivadent) veneers were prepared for bovine enamel, and randomly divided into six groups (n=5) according to the RBC used: ACC/ACSV, All Cem Veneer (FGM Dentscare); NX3C/NX3SV, NX3 (Kerr); and RVC/RVSV, RelyX Veneer (3M ESPE). ACC/NX3C/RVC underwent conventional technique cementation (C), whilst ACSV/NX3SV/RVSV received the Smart Sonic Device (SSD, FGM Denstcare) operating at 170 Hz before RBC cure reaction. OCT analysis was performed before the RBC application, 48h after cementation and 48h after thermal cycling. The OCT system (Ganymede SD-OCT, Thorlabs) operates at 930 nm central wavelength, 29 kHz axial scan rate, 8 μm lateral resolution and 5.8 μm/ 4.4 μm axial resolution in air/water, respectively. An algorithm developed in MATLAB to noise reduction and A-scan analysis to filtered images. Histograms were extracted from samples through Image J software Failures were visualized in OCT images and confirmed by A-scans. T-student and Anova were used when the cases of normality were indicated. Mann-Whitney and Kruskall-Wallis, when normality were not. The faults were clearly visualized in OCT images and confirmed by A-scans. There was no statistical difference between the conventional technique and the use of the SVD technique to avoid failures. In addition, after the thermal cycle, only RVSV presented statistically different results in relation to the other groups.

Page generated in 0.0709 seconds