• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1151
  • 12
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1192
  • 1192
  • 830
  • 756
  • 358
  • 352
  • 341
  • 310
  • 298
  • 231
  • 199
  • 154
  • 152
  • 143
  • 136
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Dosimetria em tomografia computadorizada de feixe cônico odontológica / Dental Cone Beam Computed Tomography Dosimetry

Rodrigo Antonio Pereira Mauro 13 June 2017 (has links)
Os objetivos deste trabalho foram caracterizar os níveis de referência de radiodiagnóstico para a tomografia computadorizada de feixe cônico odontológica e as características de desempenho dos equipamentos como quilovoltaqgem de pico, rendimento, camada semirredutora, etc., com o intuito de conhecer os níveis dosimétricos em que os pacientes estão expostos, permitindo assim identificar protocolos de aquisição de imagem mais adequados, levando-se em consideração os princípios de radioproteção, e também testar a capacidade de tais equipamentos em alcançar uma imagem de qualidade. A Cone Beam Computed Tomography tem se tornado ferramenta extremamente útil na utilização em procedimentos radiológicos na área odontológica, pois, a riqueza de informações que a imagem 3D trás para o planejamento cirúrgico ou em qualquer procedimento, minimiza as possibilidades de erros, possibilita diagnósticos mais confiáveis e claros, tendo influência direta no resultado final esperado pelo paciente. Por se tratar de uma técnica de imagem que utiliza radiação ionizante, deve-se ter uma atenção criteriosa voltada para os níveis de radiação, além de implementar uma rotina de controle de qualidade. O parâmetro dosimétrico mais utilizado em tomografia computadorizada é o Computed Tomography Dose Index, porém, quando aplicado à tomografia odontológica, a geometria cônica do feixe e ainda a extensão do campo de visão tornam essa grandeza inviável e enganosa, assim, faz-se necessária a padronização de uma grandeza dosimétrica mais otimizada, para evitar a subestimação dos níveis de dose em feixes de ampla abrangência. O PKA tem sido utilizado como uma possível grandeza dosimétrica em tomografia odontológica, uma vez que em sua metodologia de medida, todo o feixe é englobado pelo medidor, não depende da distância fonte - detector, além de ser sensível aos parâmetros de exposição. Diante disso, propõe-se o PKA ser utilizado para estabelecimento dos níveis de dose de referência em diagnóstico odontológico. Os valores PKA obtidos para este estudo estão em uma faixa entre 34,6 mGy.cm^2 e 2901,6 mGy.cm^2, com valor médio de 980,7 mGy.cm^2. Os valores encontrados para os níveis de referência de radiodiagnóstico calculados a partir do 3º quartil estão divididos em três classes referentes ao tamanho do campo de visão, onde para campos pequenos, médios e grandes os valores são 1241 mGy.cm^2, 1521 mGy.cm^2 e 1408 mGy.cm^2 respectivamente, e 1446 mGy.cm^2 é o valor global independente do campo de visão. Os testes de controle de qualidade foram todos positivos, com uma atenção para o i-CAT FLX, que excedeu levemente o limite aceitável para a exatidão do kVp. Uma comparação entre CTDI100 e CTDI300, reportou que o CTDI300 é em média 49% maior em relação ao CTI100. Os níveis de referência de radiodiagnóstico são representativos dos níveis de dose otimizados, e servem como base para adequação e otimização dos parâmetros de exposição do equipamento. Os testes de controle de qualidade alertam para possíveis irregularidades no funcionamento do tomógrafo, e deve complementar obrigatoriamente a rotina dos procedimentos clínicos. / The objectives of this study are to characterize the radiodiagnostic reference levels for computed tomography of dental cones and as performance characteristics of equipment such as peak kyvoltage, yield, semi-reducing layer, etc., in order to know the levels of the values in that users are exposed, thus allowing to identify more adequate image acquisition protocols, taking in basic concepts of radioprotection, and also to test the capacity of such equipment in a quality image. The Cone Beam CT scan has become active, useful in medical, medical, dental, on the Internet, in any situation, minimizes as possibilities of errors, allows for more reliable and clear diagnoses, having a direct influence on the final result expected by the patient. Because it is an imaging technique that uses ionizing radiation, careful attention should be given to radiation levels, in addition to implementing a quality control routine. The dosimetric parameter most commonly used in computed tomography is the Computed tomography dose index, however, when applied to dental tomography, the conic geometry of the beam and still the extension of the field of view make this greatness unfeasible and deceptive, so it is done The. standardization of a more optimized dosimetric quantity, to avoid an underestimation of the dose levels in beams of wide range. The PKA has been used as a possible dosimetric magnitude in dental tomography, since in its measurement methodology, the whole beam is encompassed by the meter, it does not depend on the source - detector distance, besides being sensitive to the exposure parameters. Therefore, it is proposed that PKA be used for the establishment of reference dose levels in dental diagnosis. The PKA values obtained for this study ranged from 34.6 mGy.cm^2 to 2901.6 mGy.cm^2, with a mean value of 980.7 mGy.cm^2. The values found for the levels of radiodiagnostic reference values calculated from the 3rd quartile are divided into three classes referring to the size of the field of vision, where for small, medium and large fields are the values are 1241 mGy.cm^2, 1521 mGy.cm^2 and 1408 mGy.cm^2 respectively, and 1446 mGy.cm^2 is the global independent value of the field of view. The quality control tests were all positive, with an attention to the i-CAT FLX, which slightly exceeded the acceptable limit for kVp accuracy. A face between CTDI100 and CTDI300, reported that the CTDI300 is on average 49% higher than the CTI100. Radiodiagnostic reference levels are representative of optimized dose levels and serve as a basis for adequacy and optimization of the exposure parameters of the equipment. The quality control tests alert to possible irregularities in the operation of the tomograph, and develop properly from the clinical process.
482

"Análise quantitativa das regiões glabelar e espinha nasal anterior visando à colocação de implantes para retenção de prótese nasais" / Quantitative analysis of the glabellar and anterior nasal spine regions for the placement of implants for nasal prosthesis retention

Rodrigo Nogueira dos Santos 02 December 2005 (has links)
Objetivos: Determinar a precisão das mensurações de dois pontos anatômicos craniométricos pré-estabelecidos, glabela e espinha nasal anterior, para verificar a possibilidade deles serem locais potenciais para a colocação de implantes, visando à retenção de próteses nasais. Métodos: Vinte e seis crânios secos de humanos, divididos em dois grupos iguais dos gêneros masculino e feminino, escaneados por meio de um aparelho tomógrafo espiral, de alta resolução, contínuo, com cortes axiais de 1 mm de espessura, produzidos com 1 mm de intervalo de reconstrução, por 2 segundos de tempo com filtro para tecido ósseo. As imagens obtidas foram armazenadas e transferidas para um workstation, contendo o programa de visualização e-film 1.5.3, para o processamento das imagens dos cortes axiais. A leitura destas mensurações foram realizadas independentemente por dois observadores em duas vezes cada um. Os dados obtidos foram submetidos à análise estatística, com duas variáveis, glabela e espinha nasal anterior, levando-se em consideração um fator de variação: gênero masculino e feminino. Resultados: Os valores médios obtidos para a espinha nasal anterior foram de 12,04 mm no gênero masculino e 11,62 mm no gênero feminino e, para a glabela, de 4,06 mm no gênero masculino e 3,60 no gênero feminino. Conclusões: Os pontos craniométricos avaliados apresentaram valores indicativos da possibilidade de serem utilizados para a colocação de implantes, principalmente, a espinha nasal anterior. Quanto ao gênero, na espinha nasal anterior não houve diferença entre os sexos, e na glabela houve uma pequena diferença estatisticamente insignificante. / Objectives: To determine the precision of the measurements of two preestablished craniometric anatomical points, the glabella and anterior nasal spine, in order to verify their possibility as potential locations for placing implants aimed at the retention of nasal prostheses. Methods: Twenty-six dry human crania (13 male and 13 female) were scanned by means of continuous high-resolution spiral tomography equipment, with axial slices of 1 mm in thickness that were produced with reconstruction intervals of 1mm and a record length of 2 seconds, using a filter for bone tissue. The images obtained were stored and transferred to a workstation containing the e-film 1.5.3 imaging software, to process the axial slice images. The readings of these measurements were done independently by two observers, twice for each measurement. The data obtained were submitted by means of statistical analysis using two variables (glabella and anterior nasal spine) and taking into consideration one variation factor (male or female gender). Results: The mean values obtained for the anterior nasal spine were 12.04 mm for males and 11.62 mm for females. For the glabella they were 4.06 mm for males and 3.60 for females. Conclusions: The craniometric points evaluated presented values that indicated the possibility that they could be utilized for placing implants , particularly the anterior nasal spine. With regard to gender, there was no difference for the anterior nasal spine and a small, statistically non-significant difference for the glabella.
483

"Análise das dimensões ósseas peri-orbitárias por meio de tomografia computadorizada visando a colocação de implantes osseointegráveis" / Dimensional analysis of the periorbital regions using computer tomography for osseointegrated implants insertion

Clemente da Silva Fernandes 19 April 2006 (has links)
A Prótese Buco Maxilo Facial é a especialidade da Odontologia responsável pela confecção de próteses intra e extra-bucais, indicadas quando regiões maxilofaciais foram perdidas. Implantes craniofaciais podem servir como ancoragem para próteses faciais, inclusive as óculo-palpebrais. O presente trabalho teve como propósito avaliar o comprimento e a espessura da estrutura óssea da região periorbitária e realizar a validação do método de mensuração proposto. Foram realizadas mensurações lineares de comprimento e largura das corticais ósseas das regiões peri-orbitárias em tomografias computadorizadas de 30 crânios humanos secos. Dois examinadores realizaram as mensurações, duas vezes cada um, com intervalos de no mínimo 7 dias, em pontos de referência determinados de acordo com as horas de um relógio. A análise estatística revelou que, para a grande maioria das medidas, as variações intra e inter-examinadores não apresentaram diferenças significantes (p<0,05), indicando que o método de mensuração proposto é confiável e válido para a mensuração da região peri-orbitária. Verificou-se que os três pontos de maior comprimento seguiram a mesma seqüência anatômica para as órbitas direita e esquerda, localizando-se no rebordo supra-orbitário e sendo compatíveis com a inserção de implantes osseointegráveis intra-bucais. Os três pontos localizados na parede lateral e na região látero-inferior da órbita apresentaram comprimento compatível com a utilização de implantes osseointegráveis intra-bucais. A parede medial de ambas as órbitas não apresentou comprimento favorável à inserção de implantes intra-bucais ou crânio-faciais. Os pontos de maior largura foram observados no rebordo supra-orbitário e na região látero-inferior de ambas as órbitas, e aqueles de menor largura foram encontrados na região látero-superior de ambas as órbitas. / The Maxillofacial Prosthesis is the dental specialty responsible for the confection of extra and intra-oral prosthesis indicated when facial regions have been lost. Craniofacial osseointegrated implants made possible the confection of implantretained facial prosthesis, namely the orbital prosthesis. This work aimed to evaluate the length and the thickness of the bone structure of the periorbital region and to present the validation of the method. Computer tomographies of 30 dry human skulls were made in order to register linear length and width measurements of the periorbital region. Two examiners, two times each one, took the measurements with intervals of at least 7 days between the measurements. Statistics pointed out that, for most instances, the intra and inter-examiners variations were not significant (p<0.05). Therefore, the method proposed is precise and valid for the measurement of the periorbital region. It was verified that the three points with deeper values followed the same anatomical sequence in the supraorbital rim for the right and left orbits, being compatible with the insertion of intraoral osseointegrated implants. The medial wall of both orbits did not present enough length to allow the insertion of intraoral or craniofacial implants. The points of larger width were observed in the supraorbital rim and in the infralateral region of both orbits, and those of smaller width were found in the supralateral region of both orbits.
484

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Lauren Oliveira Lima Bohner 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
485

Avaliação da precisão da tomografia computadorizada por feixe cônico (cone beam) como método de medição do volume ósseo vestibular em implantes dentários / Evaluation of the accuracy of computed tomography cone-beam (cone beam) as a method of measuring buccal bone volume in dental implants

Lucy Naomi Shiratori 07 December 2009 (has links)
A monitoração radiográfica das mudanças no nível ósseo fornece sinais valiosos para assegurarmos a longevidade e estética dos implantes. As radiografias periapicais e panorâmicas são importantes instrumentos que permitem esta avaliação, mas tem limitações, pois fornecem imagem bidimensional. As imagens tomográficas fornecem detalhes para estimar dimensões verticais e horizontais, possibilitam a melhor visualização de defeitos ósseos e estruturas anatômicas para o planejamento cirúrgico, além de permitir a monitoração radiográfica pós-cirúrgica ao redor dos implantes. O propósito deste trabalho foi avaliar a precisão da tomografia computadorizada por feixe cônico (TCCB) na medição do volume ósseo vestibular ao redor de implantes. Foram utilizados 8 crânios secos que receberam de 3 a 6 implantes na região da maxila anterior dependendo da disponibilidade óssea, em seguida foi realizada uma TCCB. Por meio dos cortes das imagens, as medições da parede óssea em 3 pontos do implante foram obtidas, analisadas e comparadas às realizadas no modelo do crânio em gesso, que continha implantes da mesma altura e diâmetro, nos mesmos pontos determinados, ou seja, no ápice do implante (A), a 5 mm do ápice (B) e do primeiro contato osso/implante até a plataforma do implante (C). O resultado do estudo mostrou que para os 3 pontos (A, B, C) não houve diferença estatisticamente significante das medidas realizadas no modelo real com a tomografia, ou seja, a TCCB pode ser um instrumento útil para se avaliar longitudinalmente o volume ósseo vestibular, porém, mais estudos clínicos se fazem necessários para ser utilizado na clínica diária. / Monitoring radiographic changes in bone level provides valuable signals to insure the longevity and aesthetics of implants. The panoramic and intra-oral radiographs are important devices for this assessment, but have limitations, they provide twodimensional images. The computed tomographics images provide details to estimate vertical and horizontal dimensions, allow for better visualization of bone defects and anatomical structures important in surgical planning, avoiding anatomical regions that could result in surgical injuries, and allows radiographic monitoring after surgery around implants , a factor of great importance for aesthetics and longevity of implants. The purpose of this study was to evaluate the accuracy of cone beam computed tomography (TCCB) in measuring the buccal bone volume around these implants. 8 skulls were used to install 3 to 6 implants in the anterior maxilla (canine to canine) depending on the availability of bone. These implants were installed in the skull, and then held a TCCB. Through the courts of the images, measurements of the bone wall at 3 points of the implant were obtained, analyzed and compared to those obtained in the model of the skull in plaster. Implants with the same height and diameter were used in the model and the same points determined, ie, the apex of the implant (A), 5 mm from the apex (B) and the first contact implant-bone to the plataform of the implant, were measured. (C).The results showed that for the 3 points (A, B, C) of the implants, no statistically significant difference in measurements obtained from the plaster model and computed tomographics images. Considering the results, TCCB can be a useful tool for assessing buccal bone volume along the implant, however, further studies are needed to be used in clinical practice.
486

Efeito do artefato de \"beam hardening\" na capacidade de identificação das alterações periodontais e peri-implantares / \"Beam Hardening\" artefact effect in identifying capacity of periodontal and peri-implant changes

Gilberto Araújo Noro Filho 09 December 2015 (has links)
Artefatos ocorrem principalmente, próximos de estruturas de alta densidade como o metal, sendo que essa alteração pode interferir na interpretação das imagens e no diagnóstico. O intuito do presente estudo é avaliar o nível ósseo ao redor de dentes e implantes por meio de dois programas diferentes e a qualidade da imagem na presença de artefatos metálicos. Foram avaliadas imagens de arquivo obtidas através do TCFC Gendex(TM) GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). Os software utilizados foram o Xelis Dental (InfinnitHealthcare, South Korea) e o OsiriX MD (Pixmeo, Geneva, Switzerland) em cortes tomográficos transaxiais de 2 mm. Foram avaliadas 145 imagens de TCFC, sendo incluídos no estudo 35 exames (as idades variaram de 35 a 83 anos), representando um total de 30 Dentes e 30 Implantes, sendo que houve uma distribuição harmônica entre os grupos em relação ao gênero e idade. Três avaliadores treinados realizaram as observações das imagens separadamente em dois períodos distintos e a qualidade da imagem foi classificada em severa, forte, moderada e mínima. Na avaliação da qualidade de imagem os implantes apresentaram uma prevalência maior de artefatos severo e forte. No entanto, as avaliações dos implantes apresentaram uma maior consistência intra-observador, demonstrando, portanto, uma maior dificuldade na classificação dos dentes. Além disso, na avaliação conjunta de dentes e implantes a consistência global dos observadores aumentou. O software OsiriX apresentou desempenho superior nas medidas lineares dos dentes e implantes na avaliação intra-examinador. Embora nenhuma das correlações intraclasse avaliadas tenha sido excelente, a grande maioria foi satisfatória, com valores entre 0,4 e 0,7. Podemos concluir que a presença de artefatos metálicos limita a qualidade da imagem do nível ósseo ao redor dos dentes e implantes, assim como o programa OsiriX apresentou resultados nitidamente superiores na avaliação das medidas lineares. / Artifacts occur mainly near high-density structures, such as metal, this alteration may affect images interpretation and diagnosis. The aim of this study is to evaluate the bone level around teeth and implants through two different software and image quality in presence of metal artefacts. Archival images obtained were evaluated by CBCT Gendex(TM)GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). The software used was Xelis Dental (InfinnitHealthcare, South Korea) and OsiriX MD (Pixmeo, Geneva, Switzerland) in transaxial tomographic slices of 2 mm. We evaluated 145 CBCT images and included in the study 35 exams (ages ranged from 35 to 83 years-old), representing a total of 30 teeth and 30 implants, there was a harmonic distribution between groups in relation gender and age. Three trained examiners made observations of images separately in two distinct periods and the image quality evaluation was classified in severe, strong, moderate and minimal. Evaluation of implants image quality presented a higher prevalence of severe and strong artifacts. However, implants evaluation presented a higher intra-observer consistency, therefore teeth assessment presents a greater difficulty. In addition, joint assessment of teeth and implants increased global consistency of observers. OsiriX software outperformed intra-examiner linear measurements of teeth and implants. Although none of the intraclass correlations evaluated has been excellent, vast majority was satisfactory, with values between 0.4 and 0.7. We conclude that presence of metal artifacts limits the image quality of bone level around teeth and implants as well as software OsiriX presented significantly better results in the evaluation of linear measurements.
487

Radiologia convencional e tomografia computadorizada na avaliação de cães portadores de discopatia torácica, toracolombar, lombar ou lombosacra: estudo comparativo / Radiographic and tomographic exams in the evaluation of dogs with disease in thoracic, thoracolumbar, lumbar or lumbosacral spine: a comparative study

Iara Levino dos Santos 01 September 2006 (has links)
Foram avaliados 58 cães portadores de discopatia nos segmentos torácico, toracolombar, lombar ou lombosacro da coluna vertebral pelos exames radiográficos simples, contrastado (mielografia) e pela tomografia computadorizada (TC). Os animais com padrão de raça definido foram os mais acometidos (88%), sendo a raça Dachshund com maior representatividade (48%). A faixa etária mais acometida foi entre 4-7 anos de idade (48%). O exame radiográfico simples detectou aspectos radiográficos compatíveis com extrusão em 29 observações. A mielografia diagnosticou 98 protrusões, 43 extrusões e 10 hérnias de disco, além de fornecer informações relativas ao grau de comprometimento medular. A TC diagnosticou 84 observações de protrusões, 48 extrusões e 2 hérnias de disco. Os espaços mais comprometidos pela extrusão diagnosticados pelos métodos empregados foram T12-13, T13-L1 e T11-12. A TC esclareceu as dúvidas sugeridas pela mielografia, embora também apresentou limitações quando a compressão medular não apresentou a presença de material hiperatenuante. Nos casos com interrupção da coluna de contraste a TC foi capaz de detectar a extrusão devido à presença de material hiperatenuante em canal medular. Os métodos de diagnóstico por imagem empregados foram complementares e forneceram informações importantes para o prognóstico desses animais. / Disc disease in thoracic, thoracolumbar, lumbar or lumbosacral spine hás been evaluated in 58 dogs by survey radiography, mielography and computed tomography. The disc disease infrequently occurs in mixed-breed dogs; Dachshunds werw at higher risk for disc disease than other breeds (48%. Most dogs are between 4-7 years of age (48%). The survey radiography showed 29 observations of extrusions. The mielography showed 98 protrusions, 43 extrusions and 10 disc herniated. The CT showed 84 protrusions, 48 extrusions and 2 disc herniated. The affected disc spaces by extrusion seen in this study were T12-13, T13-L1 and T11-12. The mielography releasedsomo doubts, that have been resolved by CT; howeverthe CT showed doubts when there wasn´t soft-tissue mineralization in vertebral canal. When thre was a complete blockage of contraste because of contrast material the CT diagnoses the disc lesion because the presence of soft tissue mineralization vertebral canal. The methods of imaging diagnosis used complete each other and provided important information used to assess prognosis of the affected animals.
488

Avaliação por tomografia computadorizada do acometimento pulmonar no pós-parto imediato / An analysis of pulmonary distress after immediate childbirth through the use of computerized tomography

Mariana Natal de Castro Meira 24 March 2009 (has links)
Durante a gravidez o sistema respiratório sofre modificações. Além da elevação do diafragma, provavelmente secundária ao aumento do volume uterino, estudos indicaram que, com a progressão da gestação algumas mudanças em volumes e capacidades pulmonares ocorrem como redução na capacidade residual funcional, volume de reserva expiratório, volume corrente e da capacidade inspiratória. Uma das hipóteses para explicar esses achados é que a elevação do diafragma pode causar colapso pulmonar, que pode ser pior em mulheres que realizaram parto cesariana (PC), quando comparadas as que tiveram parto vaginal (PV). Este estudo avaliou 20 mulheres, 2 a 5 horas após o parto em um Hospital Universitário. Após a obtenção do consentimento livre e esclarecido, 20 mulheres saudáveis, não-fumantes, onde 10 mulheres haviam realizado PV e 10 haviam realizado PC, após o parto foram submetidos à tomografia computadorizada torácica. A imagem foi analisada por um sistema de software (Osíris). A média de atenuação de cada fatia foi expresso em unidades Hounsfield (UH) e medido o percentual da área de colapso pulmonar (em g%). No grupo PV a média foi de -841,90 UH e 3,95 g%, enquanto que no grupo PC a média foi de -765,95 UH e 14,1g%. Estes resultados sugerem que as mulheres submetidas ao PC têm maior área de colapso pulmonar comparado com mulheres submetidas ao PV / During pregnancy the respiratory system undergoes several modifications. Besides the elevation of diaphragm, probably secondary to the increase in uterine volume, studies indicated that with the progression of the gestation some changes in pulmonary volumes and capacities occur, as a reduction in Functional Residual Capacity, Expiratory Reserve Volume, Tidal Volume and Inspiratory Capacity. One of the hypotheses to explain these findings is that the elevation of diaphragm may cause pulmonary collapse, which may be worse in women who underwent a cesarean section when compared to those who had vaginal delivery. This paper evaluates 20 women, 2 to 5 hours after delivery in a University Hospital. After getting informed consent, 20 healthy non-smoking women, 10 who underwent vaginal delivery (VD) and 10 who underwent a cesarean section (CS), were submitted to a chest computed tomography. The images of two different basal lung levels were analyzed by means of a software system (Osiris). The mean attenuation value of each slice in Hounsfield Units (UH) were measured and the percentage area of collapsed lung (in g%) was calculated. In the VD group the mean attenuation was - 841.90 UH and the collapsed area was 3.95 g%, while in the CS group the mean attenuation was -765.95 UH and the collapsed area was 14.1 g%. These results suggested that women who underwent a cesarean section have more collapse at basal lung levels than women who had a vaginal delivery
489

Caracterização morfológica de arco zigomático, maxila e mandíbula em indivíduos com disostose mandibulofacial / Morphological characterization of zygomatic arch, maxilla and mandible in subjects with dysostosis mandibulofacial

Priscila Padilha Moura 11 November 2016 (has links)
Introdução: as disostoses mandibulofaciais representam um grupo de condições geneticamente heterogêneas, caracterizado principalmente por hipoplasia de arco zigomático, hipoplasia mandibular e anomalias de orelhas. Objetivos: caracterizar a morfologia craniofacial de diferentes tipos de disostose mandibulofacial e investigar as alterações de mandíbula, maxila, arco zigomático e côndilo mandibular, meio de avaliação radiológica. Casuística e métodos: fizeram parte deste estudo 54 indivíduos (sendo 25 do sexo feminino e 13 do sexo masculino), com diagnóstico de disostose mandibulofacial definido por profissionais da Seção de Genética Clínica e Biologia Molecular do Hospital de Reabilitação de Anomalias Craniofaciais. Os indivíduos foram submetidos à atualização dos dados genético-clínicos e avaliação radiológica, por meio de tomografia computadorizada (helicoidal ou de feixe cônico). Para a análise morfológica, as imagens adquiridas foram reconstruídas em terceira dimensão e as estruturas craniofaciais segmentadas no software Mimics para auxiliar na descrição das alterações no arco zigomático, maxila e mandíbula A análise dos dados clínicos e morfológicos foi descritiva e em forma de tabela. Resultados: trinta e dois tinham diagnóstico genético-clínico de síndrome de Treacher-Collins, sete de disostose mandibulofacial tipo Bauru, quatro de disostose mandibulofacial tipo Guion-Almeida, um de disostose mandibulofacial com alopecia e dez de disostose mandibulofacial a esclarecer. A análise morfológica mostrou hipoplasia de osso e arco zigomático, maxila e mandíbula em todos os indivíduos avaliados e com alta variabilidade fenotípica. No entanto, os indivíduos com síndrome de Treacher Collins apresentaram um espectro fenotípico mais grave, foram observadas fissuras ósseas de Tessier número 6, 7 e 8, alterações nos côndilos mandibulares, processos coronoides, ramo e corpo mandibular. A disostose mandibulofacial com alopecia mostrou agenesia da porção temporal do arco zigomático, fissura óssea de Tessier número 8 (processo zigomático do osso temporal), mandíbula hipoplásica e assimétrica mandibular, os côndilos foram largos e os processos coronoides hipoplásicos. Na disostose mandibulofacial tipo Guion-Almeida foi observado fissura óssea de Tessier número 7, assimetria de face, hipoplasia mandibular com alterações de côndilo e anomalia de processo coronoide, a disostose mandibulofacial tipo Bauru apresentou uma hipoplasia de maxila bem acentuada com arco zigomático fino e hipoplásico, hipoplasia mandibular, côndilos hipoplásicos e alterações no processo coronoide e os casos com disostose mandibulofacial a esclarecer apresentaram hipoplasia de face média e mandíbula de grau variável e três casos apresentaram alterações esqueléticas, um caso sugere síndrome cerebrocostomandibular, um caso sobrepõe síndrome de Treacher Collins, dois casos sobrepõem os sinais clínicos de disostose mandibulofacial tipo Guion-Almeida e os outros três casos permanecem não esclarecidos. Conclusão: os achados na síndrome de Treacher Collins são mais graves dentro do grupo e os achados radiológicos da disostose mandibulofacial tipo Guion-Almeida sobrepõem aos observados na síndrome de Treacher Collins, os achados na disostose mandibulofacial tipo Bauru são mais leves que os outros grupos e a disostose mandibulofacial com alopecia apresenta um fenótipo peculiar e para os casos de disostose mandibulofacial não esclarecidos, a análise molecular é necessária para auxiliar no diagnóstico / Introduction: Mandibulofacial dysostoses are a genetically heterogeneous group of conditions characterized mainly by hypoplasia of the zygomatic arch, mandibular hypoplasia and ear anomalies. Purpose: Characterize the craniofacial morphology of different types of mandibulofacial dysostosis and investigate the anomalies in zygomatic arch, mandible, maxilla and mandibular condyle, by means of radiological evaluation. Methods: This study included 54 patients (with 25 female and 13 male) diagnosed with mandibulofacial dysostosis defined by professionals from Clinical Genetics Section and Molecular Biology by Hospital for Rehabilitation of Craniofacial Anomalies. The subjects underwent updating of clinical genetic and radiological evaluation by computed tomography (helical scan or cone beam). For morphological analysis, the acquired images were reconstructed in three dimensions and craniofacial structures were segmented in the Mimics software to assist in the description of the changes in the zygomatic arch, maxilla and mandible The analysis of clinical and morphological data was descriptive and in table form. Results: Thirty-two had genetic-clinical diagnosis of Treacher-Collins syndrome, 7 dysostosis mandibulofacial type Bauru, 4 dysostosis mandibulofacial Guion-Almeida type, 1 dysostosis mandibulofacial with alopecia and 10 with dysostosis mandibulofacial not defined.Morphological analysis showed hypoplasia of bone and zygomatic arch, maxilla and mandible in all evaluated individuals with high phenotypic variability. However, individuals with Treacher Collins syndrome presented in a more severe phenotype spectrum, Tessier cleft number were observed 6, 7 and 8, changes in mandibular condyles coronoides processes and mandibular ramus and body. The mandibulofacial dysostosis with alopecia showed agenesis of the temporal portion of the zygomatic arch, Tessier cleft number 8 (zygomatic process of the temporal bone), mandible hypoplastic and asymmetric, the condyles were broad and coronoides process hypoplastic. Mandibulofacial dysostosis Guion-Almeida type showed Tessier cleft number 7, facial asymmetry, mandibular hypoplasia with changes of condyle and coronoid process of anomaly, the mandibulofacial dysostosis type Bauru showed a well marked mandible hypoplasia with zygomatic arch hypoplastic and thin, mandibular hypoplasia, hypoplastic condyles and changes in the coronoid process and the cases with mandibulofacial dysostosis not defined had hypoplastic midface and varying degree of mandible and three cases showed skeletal changes, one case suggests cerebrocostomandibular syndrome, one case overlaps Treacher Collins syndrome, two cases overlapping clinical signs of dysostosis mandibulofacial Guion Almeida-type and the other three cases remain unclear. Conclusion: the radiological findings in Treacher Collins syndrome were more severe in the groups The radiological findings of mandibulofacial dysostosis Guion-Almeida type overlap those observed in Treacher Collins syndrome, the findings in mandibulofacial dysostosis Bauru type were lighter than the other groups and mandibulofacial dysostosis with alopecia presents a peculiar phenotype and for cases of dysostosis mandibulofacial not defined, molecular analysis is needed to aid in the diagnosis
490

Avaliação da angulação e inclinação dos dentes anteriores por meio de tomografia computadorizada por feixe cônico, em pacientes com fissura transforame incisivo unilateral / Long axis and tipping evaluation of mandible and maxilla anterior teeth by cone beam tomography in patients with unilateral cleft lip and palate

Bruna Condi Pereira de Moraes 09 June 2010 (has links)
Com a evolução da imaginologia, a tomografia computadorizada vem sendo amplamente utilizada na Odontologia. Este exame nos fornece detalhada identificação das estruturas anatômicas, e possibilita inúmeras mensurações em diversos planos, sendo uma boa indicação para avaliar indivíduos com fissura transforame incisivo, onde há a ruptura da continuidade óssea na região do rebordo alveolar e palato duro, causando várias alterações dentárias e faciais, tornando a reabilitação deste paciente um processo muito complexo. O presente estudo tem por objetivo avaliar as angulações e inclinações dentárias induzidas pelo tratamento ortodôntico corretivo, em pacientes com fissura transforame incisivo unilateral, e analisar morfologicamente o osso alveolar e contorno radicular após finalização do tratamento ortodôntico. Foram selecionados 10 pacientes, na fase de contenção após finalização do tratamento ortodôntico corretivo, e foram realizados cortes tomográficos dos seis dentes anteriores superiores e inferiores. Os dados coletados foram submetidos aos testes estatísticos. Concluímos que houve diferença significativa nas medidas do arco superior entre os lados com e sem fissuras; também foi possível a nítida visualização da relação entre as raízes dentárias com o osso alveolar. Com relação ao método utilizado, contatamos que este se mostrou confiável e reproduzível. Entretanto, novas pesquisas serão necessárias para sua consolidação. / Recent developments on the field of imaginology allowed computed tomography to become largely used in dentistry. Details of anatomic structures can be visualized with high quality images and measurements can be taken on several plans helping all professionals involved on the treatment of patients with alveolar bone defect, malocclusion and facial deformities caused by cleft lip and palate. Objectives: to evaluate tooth tipping and long axis angulation of mandible and maxilla anterior teeth produced by corrective orthodontic treatment in patients with unilateral cleft lip and palate and to analyze the morphology of alveolar bone and teeth roots after orthodontic treatment in the same group of patients. Methods: Ten patients that had received orthodontic treatment at the Craniofacial Anomalies Rehabilitation Hospital (HRAC-USP) were selected and submitted to computed tomography exam. All images taken during the exam were transferred to Dolphin Imaging Software and specific areas of anterior teeth were selected to be cutted. Measurements were taken and submitted to statistical analyses. Results: There were statistical differences between measurements of anterior teeth on both sides of the upper arch and the alveolar bone and roots interface could be well visualized. Conclusion: The results showed that this method is reliable and reproducible; however, new researches are necessary.

Page generated in 0.0931 seconds