• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1151
  • 12
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1192
  • 1192
  • 830
  • 756
  • 358
  • 352
  • 341
  • 310
  • 298
  • 231
  • 199
  • 154
  • 152
  • 143
  • 136
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
471

Detecção da neuropatia óptica distireoidiana pela quantificação dos músculos extra-oculares e da gordura orbitária na tomografia computadorizada / Predicting dysthyroid optic neuropathy using computed tomography quantitative analysis of extraocular muscles and orbital fat

Allan Christian Pieroni Gonçalves 21 September 2012 (has links)
OBJETIVO: avaliar a capacidade de índices de preenchimento muscular da órbita, calculados a partir de medidas na tomografia computadorizada de multidetectores, detectar a neuropatia óptica distireoidiana em pacientes com orbitopatia de Graves. MÉTODOS: noventa e três pacientes com diagnóstico de orbitopatia de Graves foram prospectivamente estudados. Todos os pacientes foram submetidos a um exame oftalmológico completo e à tomografia computadorizada de multidetectores. Na estação de trabalho do tomógrafo foram calculados índices baseados em medidas lineares, de área e de volume de preenchimento muscular da órbita. O índice linear de Barrett, foi calculado a partir da relação entre a medida dos músculos extra-oculares em cortes coronais no ponto médio do nervo óptico orbitário e o diâmetro da órbita na mesma posição. Nesse mesmo corte coronal uma escala de 0 a 3 foi utilizada para categorizar o grau do preenchimento muscular e de compressão do nervo óptico segundo método descrito por Nugent e colaboradores. Medidas de área foram realizadas de cortes coronais a 12, 18 e 24 mm da linha interzigomática. Três índices de área foram calculados estimando-se a razão entre a área dos músculos extraoculares e a do continente ósseo medidas. Herniação de gordura orbitária pela fissura orbitária superior foi registrada como presente ou ausente conforme método descrito por Birchall e colaboradores. Dois índices volumétricos foram calculados, o primeiro baseado em cortes axiais de todo o continente orbitário (do ápice à rima orbitária anterior) e o segundo baseado em cortes coronais da órbita a partir de um ponto médio do segmento orbitário do nervo óptico até o limite anterior do canal óptico. As órbitas foram divididas em dois grupos, um com e outro sem neuropatia óptica distireoidiana e esses grupos foram comparados entre si. RESULTADOS: cento e duas órbitas de 61 pacientes atenderam aos critérios de inclusão e foram analisadas. Quarenta e uma órbitas eram do grupo com neuropatia e 60 daquele sem a neuropatia óptica distireoidiana. Para todos os índices, exceto para o de herniação de gordura, houve diferença significativa entre os dois grupos (<0,001). A melhor combinação de sensibilidade e especificidade para o índice linear de Barrett foi de 79% e 72% respectivamente, com razão de chances de 9.2. A escala categórica de Nugent apresentou sensibilidade de 58,3% e especificidade de 84,7%, acurácia de 74,7% e razão de chances de 7,8. Todos os índices de área e de volume apresentaram boa capacidade na detecção da neuropatia óptica distireoidiana. Os índices com melhor desempenho diagnóstico foram o de área a 18mm com sensibilidade de 91,7%, especificidade de 89,9%, acurácia de 90,5% e razão de chance de 97,2, e o de volume do ápice orbitário com sensibilidade de 92%, especificidade de 86%, acurácia de 88% e razão de chance de 97,2. CONCLUSÕES: os novos índices calculados baseados em área e volume foram preditores da neuropatia óptica e apresentaram desempenho superior aos métodos reproduzidos de estudos anteriores. A continuidade dos estudos na busca de métodos objetivos e capazes de identificar a neuropatia óptica distireoidiana com cada vez maior eficiência e praticidade é de grande relevância para a melhoria do diagnóstico e do tratamento da orbitopatia de Graves e suas complicações / PURPOSE: to evaluate the ability of orbital apex crowding indexes, calculated with multidetector-computed tomography (MDCT), to detect dysthyroid optic neuropathy (DON). METHODS: ninety-three patients with GO were studied prospectively with complete neuro-ophthalmic examination and MDCT scanning. All patients underwent a complete neuro-ophthalmic examination and scanning on a MDCT. In a dedicated workstation, linear, square and volumetric indexes of the orbital apex crowding were calculated. Barretts linear index was calculated as the percentage of the orbit occupied by muscles in a coronal scan halfway between the posterior globe and the orbital apex. At the same coronal scan, the severity of optic nerve crowding was also assessed by using the subjective grading scale (0, 1, 2 or 3) described by Nugent et al. Quantitative square area measurements were performed on coronal sections 12, 18 and 24 mm from the interzygomatic line. The muscular/bony area ratio was calculated as a crowding index. Intracranial fat prolapse through the superior orbital fissure was recorded as present or absent, according to a method described Birchall at al. Two volumetric indexes were calculated, one from axial scans of the entire orbit content (up to the orbital rim) and one from coronal scans of the orbital content from the entrance of the optic canal up to the middle point of the orbital segment of the optic nerve. Orbits were divided into two groups: with or without DON and comparison between groups was performed. RESULTS: one hundred and two orbits (41 orbits with DON, and 61 without DON) of 61 patients met the inclusion criteria and were included in the analysis. All indexes, except the intracranial fat prolapse, were significantly greater in orbits with DON (<0,001). There was no significant difference regarding intracranial fat prolapse. Area under the receiver operating characteristics curves was 0.91, 0.93 and 0.87 for CIs at 12, 18 and 24 mm, respectively. The best combination of sensitivity and specificity for the Barretts index was 79%/72% and odds ratio of 9.2. The Nugents subjective grading scale detected DON with 58.3% sensitivity, 84,7% specificity, 74.7% accuracy and odds ratio 7.8. All square area and volumetric indexes calculated presented good ability to detect DON. The best performance of the square area indexes was observed at 18 mm where a cutoff value of 57.5% showed sensitivity of 91.7% and a specificity of 89.8%, accuracy 90.5% and odds ratio of 97.2. The best sensitivity/specificity ratio of the volumetric indexes was found for the one calculated at the apex, with sensitivity of 93%, specificity of 84%, and accuracy of 88% for detecting DON. CONCLUSIONS: The new orbital crowding indexes based on area and volumetric measurements found to predict DON more reliably than Barretts linear index, subjective grading of orbital crowding or intracranial fat prolapse. Further imaging studies would be useful to validate and improve objective methods to predict DON, and thus contribute to early diagnosis treatment
472

Intensidade de pixel e sua correlação com o índice de qualidade óssea de mandíbulas atróficas / Pixel intensity and its correlation with bone quality index of atrophic mandibles

Jessica Rabelo Mina Zambrana 20 May 2016 (has links)
O sucesso do tratamento de implantes dentários depende da quantidade e qualidade óssea da área de interesse e o uso da Tomografia Computadorizada por Feixe Cônico (TCFC) pode ser correlacionado para a sua estimativa. O objetivo deste estudo foi avaliar e comparar os níveis de escala de cinza dos voxels de imagens obtidas por TCFC de mandíbulas atróficas com o auxílio de programa para diagnóstico e planejamento de implantes e correlacionar a Intensidade Pixel (IP) com a classificação subjetiva do Índice de Qualidade Óssea (IQO). Foram avaliadas imagens tomográficas de 10 mandíbulas atróficas obtidas do banco de dados do LAPI-FOUSP (Laboratório para Análise e Processamento de Imagens) que receberam 8 marcações em regiões normalmente utilizadas para colocação de implantes (4 em região anterior e 4 em região posterior), sobre estas foram posicionados fios ortodônticos para padronização dos cortes tomográficos e simular posições ideais de implantes. Cortes transaxiais das áreas demarcadas foram obtidas para visualização e análise de 4 regiões corticais e 3 regiões trabeculares do tecido ósseo de cada corte, para a seleção de área foi utilizada a ferramenta Região de Interesse (ROI) de cada programa. As imagens foram analisadas por 3 programas de planejamento Romexis (Planmeca,Finlandia), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Os dados foram submetidos a análise estatística de Correlação de Spearman em um nível de significância de 5% (p<0,05), análise de correlação intraclasse intra-observador e inter-observador pelo teste Kappa ponderado e o teste qui-quadrado. Os resultados apresentaram que os programas Romexis e OsiriX apresentaram melhor acuidade para a avaliação subjetiva de qualidade óssea, em contrapartida o programa Xoran apresentou inconsistência de dados. Concluiu-se que há correlação entre Intensidade de Pixel e Qualidade óssea de acordo com os resultados encontrados para os programas OsiriX e Romexis / The success of dental implants treatment depends on the bone quantity and quality of the area of interest and the use of Cone Beam Computed Tomography (CBCT) can be correlated to an estimative. The aim of this study was to evaluate and compare the grey scale levels of voxels obtained by CBCT of atrophic mandibles with the aid of software for diagnosis and planning implants and correlates the Pixel Intensity (PI) with the subjective classification of Bone Quality Index (BQI). Tomographic images of 10 atrofic mandibles obtained from the data base of LAPI-FOUSP (Laboratory of analysis and imaging processing) were evaluated, received 8 marks in areas normally used for implant placement (4 in anterior and 4 in posterior region) on these orthodontic wires were positioned for standardization of tomographic images and simulate optimal implant positions. Transaxial slices of the demarcated areas were made for visualization and analysis of four regions of interest for cancellous bone and three regions of interest for cortical bone and for selection of each area a tool called Region of Interest (ROI) was used by each software. The images were analised by three diferent planning software, Romexis (Planmeca, Finland), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Data were subjected to statistical analysis of Spearman correlation, intraclass intra-observer and inter-observer analysis correlation and weighted Kappa concordance coefficient with 5% significance level and chi-squared test; The results presented that Romexis and OsiriX software showed better accuracy for subjective assessment of bone quality, on the other hand Xoran software showed data inconsistency. This study concluded that a correlation was found between Pixel Intensity (PI) and Bone Quality (BQ) due to the results of OsiriX and Romexis software.
473

Caracterização da displasia fibrosa em imagens de tomografia computadorizada helicoidal empregando a análise da lacunaridade / Characterization of fibrous dysplasia in helical computed tomography images employing the analysis of lacunarity

Mirna Scalon Cordeiro 04 May 2012 (has links)
A displasia fibrosa é uma alteração de desenvolvimento caracterizada pela substituição do osso normal por tecido conjuntivo denso e trabéculas ósseas imaturas, geralmente encontrada em adolescentes e adultos jovens. Uma alteração genética que envolve a proteína Gs-alfa parece ser a base do processo. A exata incidência e prevalência são difíceis de estabelecer, mas as lesões representam cerca de 5% a 7% dos tumores ósseos benignos. Nos ossos craniofaciais tem predileção pela maxila, podendo causar deformidade grave e assimetria, afetando igualmente ambos os sexos. Radiograficamente, pode apresentar diferentes padrões de imagem dependendo do grau de mineralização e maturação da lesão. .A avaliação da displasia fibrosa nas radiografias da região craniofacial pode ser difícil por causa das aparências variáveis e das estruturas que se sobrepõem, de modo que a tomografia computadorizada é um recurso relevante para o seu correto diagnóstico e planejamento de tratamento. O objetivo deste estudo foi caracterizar a displasia fibrosa através da análise da lacunaridade, um método multiescala para descrever padrões de dispersão espacial. Foram avaliados 10 pacientes (6 homens e 4 mulheres) comprometendo a maxila em sua grande maioria. Para a análise da lacunaridade, empregou-se cortes tomográficos axiais e coronais e, posteriormente, selecionou-se as regiões de interesse das áreas displásicas e do osso normal contralateral por meio do software MATLAB®. Após testes e análises estatísticas, concluiu-se que os cortes coronais, com ampliação de 3x do seu tamanho original, mostraram superioridade em relação aos axiais e, que a lacunaridade foi menor nas áreas da região displásica em relação ao osso normal, ou seja, a primeira apresentou uma maior homogeneidade de textura que a segunda. Mediante isso, pela técnica da validação cruzada leave-one-out é possível separar os grupos com uma alta acurácia (94,75%) concluindo-se que a lacunaridade é um método de análise de imagens contributivo na caracterização da displasia fibrosa. / Fibrous dysplasia is an alteration of development characterized by replacing normal bone for dense connective tissue and immature trabecular bones, typically found in teenagers and young adults. Genetic modification which involves alpha-Gs protein appears to be the basis of the process. The exact incidence and prevalence are difficult to be established, but injuries represent about 5% to 7% of benign bone tumors. On the craniofacial bones, the tumors have a predilection for the maxilla and often can cause severe deformity and asymmetry affecting both sexes equally. Radiographically, it may have different patterns depending on the image degree of mineralization and maturation of the lesion. The evaluation of radiographs of fibrous dysplasia in the craniofacial region can be difficult because of the different appearances and structures that overlaps, however, CT is an important resource for proper diagnosis and treatment planning. The aim of this study was to characterize the fibrous dysplasia by analyzing the lacunarity which is a multiscale method to describe patterns of spatial dispersion. We evaluated 10 patients (6 males and 4 females) and the maxillary was the most affected area. To the lacunarity analysis, we used an axial and coronal view and then were selected the regions of interest in the areas of dysplastic and contralateral normal bone by means of MATLAB® software. After tests and statistical analysis can be conclued that the coronal magnification 3x its original size showed superiority compared to thrust, and that the lacunarity was lower in the areas of dysplastic region in relation to normal bone, namely the first presented a more uniform texture than the second. Through this, the technique of cross-validation \"leave-one-out\" is possible to separate the groups with a high accuracy (94.75%) concluding that the lacunarity is a method of image analysis to characterize the contributory fibrous dysplasia.
474

Análise quantitativa por tomografia computadorizada da vasculatura pulmonar em pacientes com hipertensão pulmonar utilizando programa automático / Quantitative computed tomography vascular analysis in patients with pulmonary hypertension using automated software

Danilo Tadao Wada 17 June 2016 (has links)
Objetivamos neste estudo avaliar de maneira quantitativa as alterações do parênquima e da vasculatura pulmonar em exames de angiotomografia computadorizada (angioTC) de pacientes com hipertensão pulmonar (HP), utilizando programa de análise totalmente automática. Foram analisados retrospectivamente os prontuários físicos e eletrônicos e os exames de angioTC de 45 pacientes com HP, em comparação com um grupo controle. Os pacientes com HP também foram divididos de acordo com a classificação de Nice, sendo representados principalmente pelos grupos 1 (hipertensão arterial pulmonar, incluindo a idiopática) e grupo 4 (hipertensão pulmonar secundária ao tromboembolismo crônico). A análise automática mostrou que os pacientes com HP apresentaram valores menores do percentil 10 (p10) da densidade dos pulmões e valores maiores de volume vascular do lobo superior direito (LSD) e de volume vascular relativo entre lobos superiores e inferiores. Neste estudo não encontramos diferenças da análise quantitativa por TC entre os grupos de pacientes com HP. Inferimos que a diferença nos valores de p10 indique a presença das áreas hipoatenuantes de oligoemia nos pacientes com HP, enquanto as diferenças nos volumes vasculares indiquem a redistribuição da trama vascular pulmonar. A análise quantitativa da vasculatura pulmonar em imagens de angioTC pode representar uma ferramenta diagnóstica objetiva na avaliação da HP. / In this study, we aimed to quantitatively analyze the lung parenchyma and pulmonary vasculature in computadorized tomography angiography (angioCT) from patients with pulmonary hypertension (PH), using a complete automated software. We retrospectively analyzed 45 patients\'s exams and clinical records, comparing with a control group. Patients were also divided in groups, according to Nice classification, represented mainly by group 1 (pulmonary arterial hypertension, including idiopathic) and 4 (chronic thromboembolic pulmonary hypertension). In patients with PH, the automated analysis found lower values of the 10th percentile (p10) of pulmonary density and higher values of vessel volumes in the upper right lobe (RUL) and higher relative vessel volumes between the uppers and lowers lobes. In this study, we didn\'t find any difference between the groups of patients with PH in the quantitative analysis of angioCT. We infer that the p10 differences indicate presence of hypoattenuating areas of olygoemia in patients with PH and that the difference in pulmonary vessel volumes indicates pulmonary vasculature redistribution. The analysis of pulmonary vessels in angioCT images can represent an objective diagnostic tool in PH evaluation.
475

Análise quantitativa automática da vasculatura pulmonar em TCAR de pacientes com hipertensão pulmonar / Automatic quantitative analysis of pulmonary vasculature on HRCT of patients with pulmonary hypertension

Gustavo Cabrera Melges 01 June 2017 (has links)
A hipertensão pulmonar (HP) é uma doença caracterizada por elevação da pressão da artéria pulmonar e um aumento da resistência vascular pulmonar levando à disfunção do ventrículo direito, sendo complicação importante de doenças como a doença pulmonar obstrutiva crônica (DPOC), doença pulmonar intersticial (DPI), colagenoses e vasculites. A tomografia computadoriza de alta resolução (TCAR) é um dos principais métodos de diagnóstico e acompanhamento destas doenças. Neste estudo objetivamos a analise quantitativa dos exames de TCAR do tórax em pacientes com doenças parenquimatosas difusas e hipertensão pulmonar diagnosticada por cateterismo direito. Foram analisados retrospectivamente os prontuários eletrônicos e os exames de TCAR de 29 pacientes com HP, em comparação com um grupo controle. Foram excluídos os casos de hipertensão arterial pulmonar primária e tromboembolismo crônico, cuja investigação é feita prioritariamente com exame de angiotomografia. A análise quantitativa foi realizada utilizando programa completamente automático e algumas medidas manuais também foram realizadas. O pacientes com HP, quando comparados ao controle, apresentaram redução do volume pulmonar, aumento da atenuação média do parênquima, aumento na medida do volume vascular pulmonar, aumento da densidade vascular pulmonar e na relação do volume vascular nos lobos superiores em relação aos lobos inferiores. O programa automático foi capaz de identificar as alterações da vasculatura, mesmo em se tratando de exames não contrastados e em meio a alterações arquiteturais do parênquima pulmonar. Estes achados provavelmente representam a redistribuição da trama vascular pulmonar, relacionada ao aumento da resistência vascular pulmonar. A análise quantitativa automática, realizada em exames de TCAR já utilizados na rotina clínica, pode representar nova ferramenta não invasiva capaz de identificar sinais de HP em pacientes com fator de risco, como DPOC, DPI, colagenoses, em que a HP representa complicação importante e de diagnóstico muitas vezes difícil / Pulmonary hypertension (PH) is a disease characterized by elevation in the mean pressure of the pulmonary artery and an increase in the pulmonary vascular resistance leading to right heart dysfunction, being an important complication of multiple diseases such as chronic obstructive pulmonary disease (COPD), interstitial lung disease (ILD), collagen diseases and vasculitis. The high resolution computed tomography (HRCT) is one of the main diagnostic methods and is also important in the follow up of these patients. In this study we aim the quantitative analysis of the thoracic HRCT exams in patients with diffuse parenchymal lung disease and pulmonary hypertension diagnosed by right heart catheterism. We analised retrospectively the clinical records and HRCT exams of 29 patients with PH, comparing to a control group. Were excluded from the study patients with primary pulmonary arterial hypertension (PAH) and chronic thromboembolism pulmonary hypertension (CTEPH), which investigations usually include pulmonary angiotomography. The quantitative analysis was made utilizing a completely automatic software and some manual measures were also noted. Patients with PH, when comparing to control group, presented significant pulmonary volume reduction, elevated mean parenchymal attenuation, elevated measures of the pulmonary vascular volume, increase in the pulmonary vascular density and also an elevation in the relation between vascular volume in the upper pulmonary lobes and the lower lobes. The automatic software was able to identify the vascular alterations, even in non contrast enhanced exams and amidst architectural distortions in the lung parenchyma. These findings probably represent the redistribution of the pulmonary vascular bed, related to the pulmonary vascular resistance increase. .The quantitative automatic analysis, made in HRCT exams, used in clinical practice, can represent a new non invasive tool, able to identify PH signs in risc patients, such as COPD, ILD and collagen diseases, in which PH represents an important complication with, many times, difficult diagnosis.
476

Comparação entre a tomografia computadorizada multislice e a tomografia computadorizada por feixe cônico para identificação de lesões osteolíticas simuladas na cabeça da mandíbula / Comparison between multislice computed tomography and cone beam computed tomography for assessment of simulated mandibular condyle lesions

Alexandre Perez Marques 04 February 2010 (has links)
A articulação temporomandibular (ATM) apresenta diversas limitações quando se obtém imagens pela radiologia convencional. A tomografia computadorizada é o exame mais indicado, pela alta especificidade e sensibilidade, para o diagnóstico, planejamento cirúrgico e tratamento das suas lesões ósseas. O objetivo deste trabalho consiste na comparação entre a tomografia computadorizada (TC) multislice e a tomografia computadorizada por feixe cônico (TCFC) para avaliação de lesões ósseas simuladas na cabeça da mandíbula. Foram utilizadas 30 cabeças de mandíbulas maceradas onde foram criadas lesões esféricas, com o auxílio de brocas cirúrgicas esféricas de uso odontológico com tamanhos variados (nº 1, 3, 6), em suas cinco porções (anterior, lateral, posterior, medial, superior). As lesões foram submetidas a TC multislice (64 canais) e a TCFC, sendo avaliadas em dois programas de pós-processamento por dois observadores independentemente, sendo um deles em duas ocasiões distintas. Foram utilizados também dois protocolos de análise para exame das imagens quanto à presença ou não de perfuração: reconstrução multiplanar (axial, coronal, sagital) e cortes sagitais e coronais ao longo eixo da cabeça mandibular. Posteriormente, os resultados brutos foram comparados com as lesões presentes na mandíbula macerada (Padrão-Ouro) avaliando a proporção de acertos de cada observador, o grau de especificidade e sensibilidade dos diferentes métodos da TC e da TCFC, e a comparação intra-observador e inter-observadores. O teste z foi utilizado como método estatístico. Os resultados demonstraram não haver diferenças estatisticamente significantes entre os métodos em relação às porcentagens de concordância e que todos estes são validados. Os protocolos para visibilização da região de cabeça da mandíbula foram estabelecidos no intuito de melhorar a identificação da presença de alterações de cada porção da cabeça da mandíbula. Houve maior dificuldade na avaliação de lesões simuladas de pequena dimensão (broca 1) / There are many limitations for image acquisition using conventional radiography of the temporomandibular joint (TMJ) region. Computerized tomography (CT) scan is a better option due to its higher specificity and sensitivity for diagnosis, surgical planning and treatment of bone injuries. The purpose of this study is to compare multislice CT and cone beam computed tomography for evaluation of simulated mandibular condyle lesions. Spherical lesions were created in 30 dry mandibular condiyle with dentist drills (sizes 1, 3, and 6). Condyles were submitted by multislice (64 bits) CT and cone beam computed tomography (CBCT) using two independent software by 2 observants alone, one of them in 2 different occasions, using 2 protocols: axial, coronal and sagittal, and sagittal plus coronal slices for the mandibular condyle visualization. The raw data were compared with the dry mandible (gold standard) regarding the presence of injuries, evaluating the proportion of agreement, degree of specificity and sensitivity of the CT and CBCT and observant analysis. The z test were used as statistical methods. The results showed there are no statistically significant differences between the methods, and the whole methods are validity. It was observed the advantage of the association of axial, coronal and sagittal slices and sagittal plus coronal slices for detection of lesions in mandibular condyles. For some lesions localized in regions, protocols did not show statistically significant differences regarding the proportion of agreement. Protocols were created to improve the visualization of lesions in each region of the mandibular condyle. There was more difficult for assessment small size simulated lesions (# 1).
477

"Displasia fibrosa do complexo craniofacial: avaliação por meio de tomografia computadorizada e proposta de uma nova sistematização" / Fibrosa Displasia of the craniofacial complex: evaluation by means of computerized cat scan and proposal of a new systematization

Luciana Cardoso Fonseca 03 July 2006 (has links)
O objetivo deste trabalho foi avaliar diferentes aspectos da displasia fibrosa por meio da tomografia computadorizada (sítio ósseo da lesão, padrões de imagem, expansão e/ou destruição óssea) e correlacioná-los com a classificação da lesão (displasia fibrosa monostótica e craniofacial) e o sexo dos pacientes, além de sugerir uma padronização da classificação destas imagens. Foram avaliados 52 pacientes com displasia fibrosa monostótica e craniofacial por meio de cortes axiais e coronais de tomografia computadorizada. Os padrões de imagem na tomografia computadorizada foram divididos em três aspectos: hiperdenso e homogêneo (“vidro despolido”); pagetóide (hipo e hiperdenso); hiperdenso e esclerótico e hipodenso (Apesar de não ter encontrado na minha tese, este foi um padrão citado). Quando comparados os sexos, observou-se maior proporção de imagens padrão pagetóide e esclerótico no sexo feminino e padrão de imagem “vidro despolido” no sexo masculino. O padrão de imagem “vidro despolido” predominou entre as displasias fibrosas monostóticas; entre as displasias fibrosas craniofaciais, as imagens padrão “vidro despolido” e pagetóide apresentaram igual freqüência. As imagens escleróticas apresentaram proporção semelhante nos dois casos. Nos sítios ósseos com displasia fibrosa monostótica, o padrão “vidro despolido” foi predominante no esfenóide e na maxila. Além disso, foi o único padrão observado nos ossos frontal e temporal. O padrão pagetóide foi predominante na mandíbula e foi o único padrão encontrado no occipital. O padrão esclerótico só foi encontrado no temporal. Nos sítios ósseos com displasia fibrosa craniofacial, foram observados todos os três padrões de imagem no esfenóide, zigomático, maxila, etmóide, frontal e osso temporal. O padrão pagetóide foi encontrado em todos os sítios ósseos com displasia fibrosa craniofacial. O teste de Fisher mostrou não haver nenhuma associação estatística entre padrões de imagem e classificação da lesão para cada sítio ósseo (p > 0,05). Independentemente do padrão de imagem, todas as lesões apresentaram expansão da cortical. No entanto, somente as lesões com padrão pagetóide apresentaram destruição da cortical. A tomografia computadorizada é essencial na avaliação da extensão e do padrão de imagem da lesão. Uma nova padronização da classificação das imagens foi sugerida para um melhor entendimento e tratamento da doença quando correlacionada com o sítio ósseo. / The aim of this study was to determine the different computed tomography aspects (site of involvement of the lesion per bone, pattern of imaging and behavior (expansive and/or destructive) of patients with monostotic fibrous dysplasia and craniofacial fibrous dysplasia considering sex and the bone locations and to suggest a standard imaging classification. 52 patients with monostotic fibrous dysplasia or craniofacial fibrous dysplasia were studied through CT (axial and coronal slices). The images were categorized in four patterns: 1) “ground glass”, 2) pagetoid, 3) sclerotic and 4) hypodense. When the two sexes were compared, a greater proportion of pagetoid and esclerotic patterns was observed in the female while “ground-glass” in the male. The “ground-glass” pattern was predominant in the cases of monostotic fibrous dysplasia . In addition, the ground-glass” and pagetoid patterns showed equal frequency. The sclerotic images showed similar proportion in both cases. In the bone locations with monostotic fibrous dysplasia, the “ground-glass” pattern was predominant in the sphenoid and maxilla. In addition, it was the only pattern observed in the frontal and parietal bones. The pagetoid pattern was predominant in the mandible and it was the only pattern observed in the occipital. The sclerotic pattern was only found in the temporal bone. In the bone locations with craniofacial fibrous dysplasia, all patterns of imaging in sphenoid, zygoma, maxilla, ethmoid, frontal and temporal bones were observed. Furthermore, all the bone locations with craniofacial fibrous dysplasia showed the pagetoid pattern. When the Fisher test was used, statistically significant association between imaging pattern and lesion classification considering bone location was not observed (p>0.05). All lesions showed expansion of the cortical and only the lesions with the pagetoid pattern showed destruction of the cortical. Computed tomography determined the extension and imaging patterns of the bone affected with monostotic fibrous dysplasia and craniofacial fibrous dysplasia. A standard imaging classification could be established in order to clarify the diagnosis and treatment of these lesions.
478

"Validação das medidas lineares crânio-faciais por meio da tomografia computadorizada multislice em 3D" / Assessment of bone craniofacial measurements using multislice 3D-CT

Patrícia de Medeiros Loureiro Lopes 05 June 2006 (has links)
O objetivo deste trabalho foi avaliar a precisão e acurácia (validade) de medidas ósseas lineares crânio-faciais por meio de reconstruções em terceira dimensão (3D), pela técnica de volume, a partir da tomografia computadorizada (TC) multislice. O material da pesquisa consistiu de 10 (dez) crânios secos, os quais foram submetidos à tomografia computadorizada multislice 16 cortes com 0.5 mm de espessura por 0.3 mm de intervalo de reconstrução. Os dados obtidos foram enviados para uma estação de trabalho independente com o programa Vitrea®. Pontos crânio-faciais foram localizados e medidas lineares foram realizadas por 02 examinadores, previamente treinados, medindo cada um duas vezes, independentemente em 3D. As medidas físicas foram obtidas por um terceiro examinador utilizando um paquímetro digital. A análise dos dados foi feita mediante um estudo comparativo entre as medidas inter- e intra-examinadores, em 3D-TC, e entre estas e as medidas físicas obtidas diretamente nos crânios, utilizando ANOVA (análise de variância). Não foram encontradas diferenças estatisticamente significantes entre as medidas inter e intra-examinadores, nem entre as medidas físicas em 3D, com p>0,6. Em conclusão, todas as medidas lineares crânio-faciais foram consideradas acuradas e precisas utilizando a técnica de volume em 3D por meio da TC multislice. / This research objectives the assessment of the precision and accuracy (validity) of the linear craniofacial measurements in three-dimensional reconstructed volume rendered images (3D) using a multislice computed tomography (CT). The study population consisted of 10 (ten) dry skulls, previously selected, without distinction of ethnic group and sex, which were submitted to a multislice CT 16 slices using 0.5 mm of slice thickness and 0.3 mm of interval of reconstruction. Subsequently the data were sent to an independent workstation with Vitrea software. Conventional craniofacial points were localized and linear measurements were obtained by 02 examiners, previously calibrated, twice each, independently, in 3D images. The physical measurements were obtained by a third examiner using a digital caliper. The data analysis was carried out, regarding to inter and intra examiner, in 3D-CT, and between image and physical measurements from dry skulls, using ANOVA (analysis of variance). There were also no statistically significant differences between imaging and physical measurements with p>0.6 for all measurements. In conclusion, all the linear craniofacial measurements were considered accurate and precise using a 3D volume rendering technique by multislice CT.
479

Desenvolvimento e aplicação de um simulador pediátrico craniano para dosimetria em tomografia computadorizada / Development and application of a pediatric head phantom for dosimetry in computed tomography

Elaine Wirney Martins 10 May 2016 (has links)
Para avaliar os níveis de exposição e a dose absorvida em pacientes submetidos a exames de tomografia computadorizada, TC, é necessário calcular os índices de dose em medições com um simulador de PMMA, ou cheio de água. O simulador deve ser capaz de reproduzir as características de absorção e espalhamento do corpo ou parte do corpo humano em um campo de radiação. As grandezas específicas em TC: índice de kerma livre no ar (Ca,100), índice de kerma no ar ponderado (CW), índice de kerma no volume total (Cvol) e produto kerma no ar-comprimento (PKL) devem ser determinadas e comparadas com os níveis de referência já existentes na literatura. Neste trabalho foi desenvolvido um simulador pediátrico craniano, já que no Brasil os níveis de referência para diagnósticos (NRDs) disponíveis foram determinados baseados em um simulador padrão adulto. O simulador desenvolvido inovou em sua construção apresentando materiais que simulam a calota craniana em osso cortical (alumínio) e osso esponjoso (PVC). O seu interior foi preenchido com água destilada. As dimensões foram escolhidas de acordo com as recomendações da Organização Mundial da Saúde e do International Commission on Radiation Units, para o tamanho da cabeça de uma criança de 0 a 5 anos: 160 mm de diâmetro e 155 mm de altura. A calota craniana tem uma espessura de 4 mm e diâmetro interno de 111,9 mm. Para avaliar seu comportamento foram realizados testes em laboratórios e em feixes clínicos. Os resultados apresentaram uma atenuação de até 23% na utilização dos materiais que simulam a calota craniana evidenciando que os valores adotados para os cálculos de NRD podem estar superestimando a dose recebida por pacientes pediátricos. Percebe-se que a dose recebida em exames de crânio apresenta uma distribuição diferente por ser parcialmente atenuada e/ou retroespalhada pela calota craniana, o que não é considerado ao se utilizar o simulador constituído apenas de PMMA. / To determine the exposure levels and the absorbed dose in patients undergoing CT scans, is necessary to calculate the CT dose index in measurements with a PMMA or water phantom. The phantom must be enough to simulate the attenuation and scattering characteristics of a human body or parts in a radiation field. The CT specific quantities : CT air kerma index (Ca,100) , weighted CT air kerma index (CW ), a total volume CT air kerma index (Cvol) and the CT air kerma-lenght product (PKL) must be determined and compared to literature reference levels. In this work a head pediatric phantom was developed, considering that the Brazilian published Diagnostic Reference Levels (DRL) are based on adult phantom measurements. This developed phantom shows a construction innovation using materials to simulate the skullcap, cortical bone (aluminum) and cancellous bone (PVC), and it was filled with distilled water. The phantom dimension follows the recommendations of the World Health Organization and the International Commission on Radiation Units for children from 0 to 5 years old head size: diameter of 160 mm and height of 155 mm. The skullcap has 4 mm of thickness and 111.9 mm of internal diameter. In order to evaluate its behavior, tests were carried out in calibration laboratories and in clinical beams. The results showed attenuation up to 23% when different materials are used as skullcap, demonstrating that the DRLs adopted could be overestimating the dose received by pediatric patients. It is observed that the dose received by CT skull scans presents different distribution, due to the skullcap partially attenuation and/or backscattering which is not considered when the PMMA phantom is used.
480

Modelagem de grãos confinados em invólucros utilizando redes complexas e métodos de imagem / Confined grain modeling using complex networks and image processing methods

Gustavo Vrech Rigo 11 June 2015 (has links)
A forma&ccedil;&atilde;o de arcos &ndash; estruturas que promovem a anisotropia de for&ccedil;as dentro de um sistema &ndash; acontece corriqueiramente dentro de silos ou maquinaria agr&iacute;cola. A presente tese prop&otilde;e um modelo baseado em redes complexas para modelar tal fen&ocirc;meno, definindo cada gr&atilde;o como v&eacute;rtice e a for&ccedil;a que dois gr&atilde;os trocam como o peso de uma liga&ccedil;&atilde;o entre eles. A partir de ensaios tomogr&aacute;ficos de 11 diferentes tipos de gr&atilde;os foi desenvolvido um m&eacute;todo para transformar cada uma das imagens tridimensionais resultantes numa rede complexa. Cada imagem foi pr&eacute;-processada e submetida a uma transformada watershed utilizando como marcadores internos a eros&atilde;o da pr&oacute;pria imagem. Este processo tridimensional resultou na segmenta&ccedil;&atilde;o de cada um dos gr&atilde;os da imagem original, tornando poss&iacute;vel a extra&ccedil;&atilde;o de propriedades f&iacute;sicas de cada gr&atilde;o, como massa, centro de massa, momento de in&eacute;rcia, e as for&ccedil;as &agrave;s quais este est&aacute; submetido. A partir destes dados, a rede complexa de cada uma das 11 amostras foi constru&iacute;da. A amostra da soja foi comparada com um padr&atilde;o-ouro pr&eacute;-estabelecido possibilitando eventuais refinos no m&eacute;todo. As reconstru&ccedil;&otilde;es tridimensionais segmentadas de cada amostra apresentaram um resultado visual aceit&aacute;vel, embora algumas segmenta&ccedil;&otilde;es tenham sofrido com o efeito do elemento estruturante da eros&atilde;o, uma vez que este tem de ser grande o suficiente para segmentar gr&atilde;os adjacentes, por&eacute;m n&atilde;o o suficiente para super-segmentar um &uacute;nico gr&atilde;o. A rede complexa formada a partir da imagem de soja foi submetida a uma an&aacute;lise mais profunda, estudando e normalizando sua propriedade strength, uma natural candidata para detectar anisotropia de for&ccedil;as. Os v&eacute;rtices com alto valor normalizado de strength foram definidos como o arco da estrutura, e sua an&aacute;lise visual permitiu concluir que estes de fato s&atilde;o os elementos respons&aacute;veis pela estrutura do arranjo, assim como substanciar o sucesso do m&eacute;todo aqui proposto em detectar automaticamente o arco utilizando uma imagem tridimensional. / The formation of arches &ndash; structures that promotes force anisotropy within a system &ndash; appears routinely inside silos or agricultural machinery. This current thesis proposes a method for modeling this phenomenon as a complex network, defining each grain as vertex and a force that two grains exchanges as the weight of the link between them. By using computed tomography, 3D images were taken from 11 grain samples, and a method developed to transform each of this resulting images in a complex network. Each image had to be pre-processed and subjected to a watershed transform using as inner markers the erosion of the image itself. This process resulted in three-dimensional segmentation of each grain of the original image, allowing the estimation of the physical properties of each grain, such as mass, center of mass, moment of inertia and the forces to which the grain is subjected. From these measures, the complex network of each of the 11 samples was constructed. Sample soybeans were compared with a gold-standard, allowing improvements to the methodology. The segmented three-dimensional reconstructions of each sample provided acceptable visual output, although some samples suffered from erosion due to the structural element size, since it must be large enough to segment adjacent grains, but not enough to super-segment a single grain. The complex network obtained from the soybeans image was subjected to further analysis, studying and normalizing its strength property, a natural candidate to detect force anisotropy. Vertices with high normalized values of strength were understood as defining the arch of the structure, and its visual analysis showed that these indeed are the elements responsible for the arrangement structure. These results support the ability of the proposed method in automatically detecting the arches using as input a three-dimensional image.

Page generated in 0.0746 seconds