• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 75
  • 67
  • 66
  • 63
  • 61
  • 22
  • 22
  • 20
  • 18
  • 16
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnóstico diferencial das manifestações pulmonares agudas do lúpus eritematoso sistêmico com o auxílio da tomografia computadorizada

Veloso, Júlia de Castro Vieira January 2019 (has links)
Orientador: Sergio Marrone Ribeiro / Resumo: Introdução: O Lúpus Eritematoso Sistêmico (LES) é uma afecção reumatológica autoimune, de etiologia multifatorial, mais comum em mulheres na menacme. O comprometimento pulmonar pelo LES pode culminar com complicações pulmonares agudas como a Pneumonite Lúpica aguda (PLA), Hemorragia Alveolar Difusa (HAD) ou Pneumonia infecciosa (PN), com altos índices de morbimortalidade e tratamentos diferentes. Objetivos: Estabelecer o número de casos de complicações pulmonares agudas do LES e analisar suas manifestações tomográficas, com o propósito de caracterizar os padrões de acometimento pela PLA, HAD e PN, além de apontar achados de imagem e parâmetros clínicos e laboratoriais que auxiliem no diagnóstico diferencial entre elas. Método: Estudo observacional descritivo e retrospectivo, do tipo de série de casos, no qual foram analisados os prontuários eletrônicos dos pacientes com diagnóstico de LES entre Janeiro de 2011 e Dezembro de 2018 que apresentaram PLA, HAD ou PN. Foram colhidos dados do prontuário eletrônico e analisadas as Tomografias Computadorizadas de Alta Resolução (TCAR). Resultados: Dentre os 359 pacientes com diagnóstico de LES acompanhados no serviço, foram identificados 21 eventos independentes de complicações pulmonares agudas, sendo eles 12 episódios de PLA, 6 de PN e 3 de HAD. Os episódios de PN apresentaram maior prevalência de leucocitose e consolidações à TCAR, metade deles com vidro fosco. Metade dos eventos de PLA apresentou uma relação entre velocidade de hem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: Systemic Lupus Erythematosus (SLE) is an autoimmune disease with multifactorial etiology, more common in reproductive age women. Pulmonary involvement by SLE may lead to acute pulmonary complications such as acute Lupus Pneumonitis (ALP), Diffuse Alveolar Hemorrhage (DAH) or infectious pneumonia (PN), with high morbidity and mortality rates and different treatments. Purpose: To establish the number of cases of acute pulmonary complications of SLE and analyze their tomographic manifestations, in order to recognize the patterns of involvement by ALP, DAH and PN, besides pointing out image findings, clinical and laboratory parameters that help distinguishing them. Methods: Descriptive, retrospective and observational study, in which electronic records of patients diagnosed with SLE between January 2011 and December 2018 who presented PLA, HAD or PN were analyzed. Data was obtained from the electronic medical record and the High Resolution Computed Tomographies (HRCT). Results: Among the 359 patients diagnosed with SLE followed in this service, 21 independent events of acute pulmonary complications were identified. There were 12 episodes of ALP, 6 of PN and 3 of DAH. PN episodes had a higher prevalence of leukocytosis, consolidations at HRCT and half of them had ground glass opacities. Half of the ALP events had an erythrocyte sedimentation rate and C-reactive protein (CRP) ratio above 15, with CRP within the limits of normality in 83,33%. One-third of ALP events ha... (Complete abstract click electronic access below) / Mestre
2

Produção de I-124 com uso de nanomateriais e sua biodistribuição em animais / Production of I-124 with the use of nanomaterials and their biodistribution in animals

Braghirolli, Ana Maria Silveira January 2014 (has links)
Made available in DSpace on 2016-03-04T13:41:31Z (GMT). No. of bitstreams: 2 302.pdf: 3625157 bytes, checksum: ca6d182c8145cf96e7effa7478c72dc1 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2014 / O iodo-124 é um emissor de pósitron com 4,2 dias de meia vida física. Seu decaimento dá-se por emissão de pósitrons (23,3 por cento) e captura eletrônica (76,7 por cento). Suas características físicas e químicas o tornam um isótopo atrativo para aplicações médicas. O desenvolvimento de novas técnicas de imagens, melhorias na tecnologia de Tomografia por Emissão de Pósitrons (PET), o desenvolvimento de novos detectores e métodos computacionais de processamento de sinal, abrem novas perspectivas para a sua aplicação. Os crescentes usos da tecnologia PET em oncologia, em estudos de farmacocinética e de metabolismo de drogas, fazem dos radiofármacos marcados com 124I uma ferramenta de grande interesse e utilidade. O uso de moléculas marcadas com 124I destaca-se especialmente devido à conveniente meia-vida do 124I. Esta característica possibilita diagnósticos por imagens, em centros PET longe do local de produção de radionuclídeos. Dentro deste contexto, este trabalho apresenta um método de produção e separação de 124I. Este método é inovador e pioneiro no país. Baseia-se no desenvolvimento e utilização de alvos de natTeO2 nanoestruturados. Estes alvos são irradiados em um acelerador de partículas carregadas, de energia variável, o cíclotron CV-28 do IEN. As irradiações são realizadas com feixes de prótons de 24 MeV de energia inicial. / Na preparação dos alvos nano particulados o destaque foi a simplicidade do método, que usa a técnica de sol-gel para obtenção de nano partículas, o TeCl4 como precursor e a água como solvente. O 124I produzido foi separado do material alvo por destilação seca e capturado numa solução de NaOH (0,02M), em sistema automatizado. O rendimento de alvo grosso foi de 6,81 MBq/μAh, sendo o rendimento da síntese de aproximadamente 90%. O 124I obtido foi então utilizado em estudos preliminares de biodistribuição. Estes estudos foram realizados em um MicroPET, modelo LabPET 4 do CDTN, em camundongos tipo Swiss. Os resultados da aplicação de Na124I mostraram alta qualidade de imagem PET da tireoide, sendo que a máxima captação deu-se 6 h após injeção.
3

Desenvolvimento da formulação de um kit liofilizado de dota-toc para marcação com gálio-68 para diagnóstico em tomografia por emissão de pósitrons

Nabinger, Patrícia Machado January 2015 (has links)
Made available in DSpace on 2015-06-20T02:07:32Z (GMT). No. of bitstreams: 1 000470623-Texto+Parcial-0.pdf: 1446399 bytes, checksum: 3695d8ae78a5226ff8ef00bf63332a89 (MD5) Previous issue date: 2015 / The gallium-68 (68Ga), an extremely promising positron-emitting radionuclide, has major advantages when compared to other radionuclides used in Positron Emission Tomography (PET), like fluor-18 and carbon-11. Differently from these PET radionuclides, gallium-68 is available from a 68Ge/68Ga generator, which allows its distribution even in nuclear medicine centers located far from cyclotrons. In recent years, an increase in the use of 68Ga PET radiopharmacy was observed around the world. However, in Brazil there is still only four centers with this technology available, mainly due to the difficulty in the access. Radiopharmaceuticals used for diagnostics are scarcely accessible in our country. Among radiopharmaceuticals most used around the world are the DOTA-peptides, somatostatin analogs for the diagnosis of neuroendocrine tumors. Considering the present scenario, this study aimed to develop a diagnostic kit of DOTA-TOC for labeling with 68Ga, with high radiolabeling yield and high radiochemical purity, thus stimulating the use of this innovative radionuclide in Brazil. / O Gálio-68 (68Ga), um radionuclídeo emissor de pósitrons extremamente promissor, apresenta grandes vantagens quando comparado a outros radionuclídeos para uso em Tomografia por Emissão de Pósitrons (PET), como o flúor-18 e carbono-11. Diferentemente destes radionuclídeos, que são produzidos em cíclotrons, o 68Ga é produzido em gerador a partir de um radionuclídeo de longa vida útil, o Germânio-68 (68Ge), o que permite sua distribuição mesmo em centros de Medicina Nuclear que se localizem muito distantes de cíclotrons. Apesar de a radiofarmácia com 68Ga ter se desenvolvido muito nos últimos anos em todo o mundo, o Brasil ainda tem somente quatro centros que possuem essa tecnologia disponível. Isto se deve especialmente à dificuldade de utilização, já que os peptídeos necessários para a marcação dos radiofármacos são importados. Dentre os radiofármacos que estão sendo mais utilizados no mundo, destacam-se os DOTA-peptídeos, análogos da somatostatina utilizados no diagnóstico de tumores de origem neuroendócrina. Diante do cenário atual, este trabalho teve por objetivo o desenvolvimento de um kit diagnóstico de DOTA-TOC para marcação com 68Ga, com altos rendimento de marcação e pureza radioquímica, e, assim, estimular a utilização desse radionuclídeo inovador no Brasil.
4

Estudo da estratégia de harmonização da quantificação do SUV em imagens de PET/CT

Fischer, Andréia Caroline Fischer da Silveira January 2014 (has links)
Made available in DSpace on 2014-12-06T01:01:32Z (GMT). No. of bitstreams: 1 000462943-Texto+Completo-0.pdf: 4086036 bytes, checksum: 8b6abefa3b76b3bc43dbf4ca084a593b (MD5) Previous issue date: 2014 / In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative and quantitative assessments in different scopes. We concluded that the harmonization strategy of the SUV quantification presented in this paper was effective in reducing the variability of small structures quantification. However, for the comparison of SUV quantification between different scanners and institutions, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation is maintained, in order to minimize the SUV variability due to biological factors. / Na rotina clínica, imagens de PET/CT, costumam ser analisadas qualitativamente, mediante a comparação visual entre a captação nos tecidos hipercaptantes e nos tecidos normais; e, semiquantitativamente, por meio de um parâmetro denominado SUV (do inglês Standardized Uptake Value). Para garantir que estudos longitudinais adquiridos em distintos equipamentos sejam intercambiáveis e informações de quantificação sejam comparáveis, torna-se necessário o estabelecimento de uma estratégia de harmonização da quantificação do SUV. O objetivo geral deste estudo é avaliar uma estratégia de harmonização da quantificação de imagens de PET/CT, realizada com equipamentos de diferentes modelos e fabricantes. Para tanto, foi realizado um levantamento das características técnicas do equipamento e dos protocolos de aquisição das imagens clínicas de distintos serviços de PET/CT do estado do Rio Grande do Sul. Para cada equipamento, foram determinadas a acurácia da quantificação do SUV e as curvas de Coeficiente de Recuperação (RC, do inglês Recovery Coefficient), utilizando os parâmetros de reconstrução clinicamente disponíveis e relevantes. A partir desses dados, foram identificadas as especificações de desempenho harmonizáveis dentre os equipamentos avaliados, assim como o algoritmo que produz, em cada equipamento, a quantificação mais acurada. Finalmente, foram identificados os parâmetros de reconstrução mais adequados à harmonização da quantificação do SUV em cada equipamento, em âmbito regional e internacional. Constatou-se que os valores de RC dos equipamentos analisados mostraram-se superestimados em até 38%, particularmente para objetos de dimensões maiores do que 17 mm. Estes resultados mostram a necessidade de uma otimização, mediante a modificação dos parâmetros de reconstrução utilizados e até mesmo da mudança do algoritmo de reconstrução utilizado em cada equipamento. Observou-se que existe uma dissociação entre a melhor imagem para análise qualitativa e a melhor imagem para quantificação dos estudos de PET/CT. Assim, a escolha do método de reconstrução deve estar atrelada à finalidade do estudo de PET/CT em questão, visto que um mesmo algoritmo de reconstrução não se mostra adequado, em um único equipamento, às avaliações qualitativas e quantitativas, em diferentes âmbitos. Conclui-se que a estratégia de harmonização da quantificação do SUV apresentada neste trabalho mostrou-se eficaz na redução da variabilidade da quantificação de pequenas estruturas. Entretanto, para que a quantificação do SUV possa ser comparada entre diferentes equipamentos e instituições, é fundamental que, além da harmonização da quantificação, seja mantida a padronização da metodologia de preparo do paciente, visando minimizar a variabilidade atribuída ao SUV decorrente de fatores biológicos.
5

Estudos de aterosclerose experimental utilizando tomografia por emissão de pósitrons (PET-Scan)

Soraya Megumi Kazuma 24 May 2017 (has links)
A aterosclerose é caracterizada como uma doença imune-inflamatória crônica das artérias devido ao grande acúmulo de lipídios na íntima. Um dos fatores envolvidos na progressão da aterosclerose é a presença de uma subfração de partículas de lipoproteína de baixa densidade (LDL) com um grau mínimo de modificação, denominada LDL eletronegativa [LDL(-)], que possui propriedades pró-inflamatórias, apresenta maior retenção na íntima das artérias e maior tempo de permanência na circulação sanguínea, gerando respostas imuno-inflamatórias. Epítopos de anticorpos monoclonais importantes no reconhecimento das partículas de LDL(-) foram mapeados por phage display, gerando peptídeos mimotopos (P1A3 e P2C7) com potencial para acompanhamento da progressão da aterosclerose, sendo excelentes candidatos como radiotraçadores marcados com emissores de pósitrons para obtenção de imagens moleculares por tomografia por emissão de pósitrons (PET) associada à tomografia computadorizada (PET/CT). O peptídeo P1A3 foi radiomarcado com 64Cu através da complexação com o quelante DOTA, obtendo-se imagens por PET/CT da captação do peptídeo na região do arco aórtico de camundongos knockout para a apolipoproteína E (Apoe-/-) comparados com animais controle sem lesões ateroscleróticas. Antes da obtenção das imagens PET/CT, os peptídeos radiomarcados foram validados através de estudos de estabilidade e biodistribuição, acumulando-se rapidamente nos rins. Também foi sintetizado um nanocluster de ouro, marcado com 64Cu e funcionalizado com P1A3 em sua superfície, observando-se o maior direcionamento dos nanoclusters de ouro ligados ao P1A3 para a região das lesões ateroscleróticas do arco aórtico de camundongos Apoe-/-, comparado ao nanocluster controle. Os peptídeos P1A3 e P2C7 radiomarcados com 68Ga, foram também avaliados por imagens PET/CT em camundongos knockout para o gene do receptor da LDL (LDLr-/-) tratados ou não com dieta hipercolesterolêmica. As imagens PET/CT mostraram que os peptídeos marcados com 68Ga tiveram um aumento de captação na região do arco aórtico de camundongos LDLr-/- hipercolesterolêmicos em relação ao controle. Além disso, P2C7 foi radiomarcado com 99mTc e sua biodistribuição demonstrou uma relação maior de % atividade injetada (AI)/órgão da aorta/coração nos camundongos hipercolesterolêmicos, em concordância com a imagem obtida por SPECT (tomografia computadorizada por emissão de fóton único) que revelou maior captação no arco aórtico.
6

Produção de I-124 com uso de nanomateriais e sua biodistribuição em animais

BRAGHIROLLI, Ana Maria Silveira 05 1900 (has links)
Submitted by Almir Azevedo (barbio1313@gmail.com) on 2014-07-28T16:55:19Z No. of bitstreams: 0 / Made available in DSpace on 2014-07-28T16:55:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2014 / O iodo-124 é um emissor de pósitron com 4,2 dias de meia vida física. Seu decaimento dá-se por emissão de pósitrons (23,3%) e captura eletrônica (76,7%). Suas características físicas e químicas o tornam um isótopo atrativo para aplicações médicas. O desenvolvimento de novas técnicas de imagens, melhorias na tecnologia do Tomografia por Emissão de Pósitrons (PET), o desenvolvimento de novos detectores e métodos computacionais de processamento de sinal, abrem novas perspectivas para a sua aplicação. Os crescentes usos da tecnologia PET em oncologia, em estudos de farmacocinética e de metabolismo de drogas, fazem dos radiofármacos marcados com 124I uma ferramenta de grande interesse e utilidade. O uso de moléculas marcadas com 124I destaca-se especialmente devido à conveniente meia-vida do 124I. Esta característica possibilita diagnóstico por imagens, em centros PET longe do local de produção de radionuclídeos. Dentro deste contexto, este trabalho apresenta um método de produção e separação de 124I. Este método é inovador e pioneiro no país. Baseia-se no desenvolvimento e utilização de alvos de natTeO2 nanoestruturados. Estes alvos são irradiados em um acelerador de partículas carregadas, de energia variável, o cíclotron CV-28 do IEN. As irradiações são realizadas com feixes de prótons de 24 MeV de energia inicial. Na preparação dos alvos nanos particulados o destaque foi a simplicidade do método, que usa a técnica de sol-gel para obtenção de nano partículas, o TeCl4 como precursor e a água como solvente. O 124I produzido foi separado do material alvo por destilação seca e capturado numa solução de NaOH (0,02M), em sistema automatizado. O rendimento de alvo grosso foi de 6,81 MBq/Ah, sendo o rendimento da síntese de aproximadamente 90%. O 124I obtido foi então utilizado em estudos preliminares de biodistribuição. Estes estudos forma realizados em um MicroPET, modelo LabPET4 do CDTN, em camundongos tipo Swiss. Os resultados da aplicação de Na124I mostraram alta qualidade de imagem PET da tireoide, sendo que a máxima captação deu-se 6h após injeção / Iodine-124 is a positron emitter with physical half-life of 4.2 days. Its decay occurs by positron emission (23.3%) and electron capture (76.7%). Their physical and chemical characteristics make it an attractive isotope for medical applications. The development of new imaging techniques, improvements in Positron Emission Tomography (PET), the development of new detectors and computational methods of signal processing, open new perspectives for its application. The increasing use of PET technology in medical oncology, pharmacokinetics and drug metabolism, make the radiopharmaceuticals labeled with 124I a tool of great interest and usefulness. The use of 124I - labeled molecules stands out particularly due to the convenient half-life of 124I. This feature enables diagnostic imaging in PET centers far away from the radionuclides producing center. Within this context, this work presents a method for the production and separation of 124I. This method is innovative and pioneering in the country. It is based on the development and use of nanostructured targets of natTeO2. These targets are irradiated in a charged particles accelerator, with variable energy, the IEN´s CV-28 cyclotron. The irradiations are performed with 24 MeV, initial energy, proton beams. In the preparation of nanoparticulated targets the highlight was the simplicity of the method that uses the sol-gel technique for obtaining nanoparticles, TeCl4 as precusor and water as solvent. The produced 124I was separated from the target material by dry distillation and trapped in a NaOH solution (0.02M), in an automated system. The thick target yield was 6.81 MBq/Ah, and the synthesis yield was 90%. The 124I obtained was then used in preliminary biodistribution studies. These studies were performed on a microPET, model LabPET 4 of the CDTN, in Swiss type mice. The results of the application of Na124I showed high quality PET imaging of the thyroid, with the maximun uptake at 6h after injection
7

Caracterização da atividade antitumoral das tiossemicarbazonas derivadas de N(4)-Metil-Toluil-2-acetilpiridina e de 2-piridinoformamida e seus complexos metálicos: avaliação do potencial radiofarmaceutico / CHARACTERIZATION OF THE ANTITUMURAL ACTIVITY OF THE THIOSEMICARBAZONES DERIVED FROM N(4)-METHYL-TOLYL-2- ACETYLPYRIDINE AND 2-PIRIDINOFORMAMIDE AND ITS METAL COMPLEX: EVALUATION OF THE RADIOPHARMACEUTICAL POTENTIAL.

Paulo Roberto Ornelas da Silva 25 July 2008 (has links)
As tiossemicarbazonas têm despertado grande interesse farmacológico por causa de suas propriedades biológicas, tais como a atividade citotóxica contra várias linhagens de tumores humanos. A maioria destes compostos sintetizados é baseada na piridina, por causa da sua semelhança a metabólitos piridoxal que estão presentes na co-enzima B6. Os objetivos deste estudo foram a caracterização do efeito antitumoral de tiossemicarbazonas derivadas de N(4)-metil-toluil-2-acetilpiridina e 2- piridinoformamida e o desenvolvimento de um radiofármaco baseado num complexo metálico de tiossemicarbazona para aplicação na tomografia por emissão de pósitron (PET). Na primeira fase deste trabalho foram sintetizadas vinte e uma tiossemicarbazonas, derivadas de N(4)-metil-toluil-2-acetilpiridina e 2-piridinoformamida, bem como seus complexos metálicos (Sn, Ga e Cu), para se avaliar seus potenciais citotóxicos e antiproliferativos in vitro sobre células de tumores cerebrais e mamários. Nossos resultados mostraram que todas tiossemicarbazonas testadas apresentaram potente efeito citotóxico e antiproliferativo contra linhagens de células de glioblastoma multiforme e carcinoma de mama, com valores de IC50 (concentração do composto que produziu 50% de morte celular) na ordem de nanomolar. Além disso, foram observadas alterações morfológicas como arredondamento celular, redução do volume citoplasmático e condensação da cromatina, característicos do mecanismo apoptótico. O cloreto de cobre foi usado como controle e apresentou o valor da IC50 na ordem de milimolar, indicando que a complexação do cobre com tiossemicarbazona foi capaz de aumentar mais de 1 milhão de vezes a potência antitumoral deste metal. Na segunda etapa deste trabalho, devido a potente atividade antitumoral das tiossemicarbazonas derivadas de N(4)-metil-toluil-2-acetilpiridina e das excelentes propriedades do 64Cu (T1/2= 12,7 h, decaimento por β+, β- e EC) foi desenvolvido um novo agente de imagem (radiofármaco) para detecção de tumores através da PET. Os radiofármacos foram produzidos no reator nuclear TRIGA-IPR-R1 do CDTN, via reação de captura neutrônica 63Cu(n, y)64Cu, do complexo de cobre N(4)-orto-toluil-2- acetilpiridina tiossemicarbazona (Culac). A maior atividade específica induzida foi 5,55 MBq/mg. Depois de irradiadas, as amostras de 64Culac foram analisadas por espectroscopia de absorção no infravermelho (IV) para se avaliar a integridade estrutural química. Todos os compostos irradiados mantiveram sua estrutura química íntegra. Em seguida, foi avaliada a manutenção da atividade antitumoral in vitro do 64Culac, pelo ensaio do MTT, nas linhagens de células RT2 (p53 selvagem), T98 (p53 mutante), MCF-7 (p53 selvagem), CAE (p53 selvagem). Os resultados mostraram a manutenção da potente atividade antitumoral do 64Culac em todas as células tratadas e apresentou valores da IC50 da ordem de nanomolar. Os estudos de biodistribuição do 64Culac, realizados por injeções via endovenosa caudal, em camundongos implantados nos coxins plantares com tumor de Ehrlich mostraram captação significativa na pata com tumor (razão tumor/músculo esquelético de 6,55) em relação ao controle no tempo de 240 minutos após administração deste composto. Estudos histopatológicos revelaram leve hepatotoxicidade após 144 horas (6 dias) da administração endovenosa de 136 μg/kg do Culac. Contudo, nesta dose não foi observada letalidade, nem alterações comportamentais, locomotoras ou nutricionais nos animais. Os nossos resultados demonstraram que o complexo de cobre-64 N(4)-orto-toluil-2- acetilpiridina tiossemicarbazona (64Culac) é um promissor radiofármaco para detecção de tumores sólidos pela tomografia por emissão de pósitrons (PET). / Thiosemicarbazones have attracted great pharmacological interest because of their biological properties, such as cytotoxic activity against multiple strains of human tumors. The most studied compounds are pyridine-based because of their resemblance to pyridoxal metabolites that attach to co-enzyme B6-dependant enzymes. This work aimed the characterization of the antitumoral effect of N(4)-methyl-tolyl-2-acetilpiridine and 2- pyridinoformamidederived thiosemicarbazones and the development of a radiopharmaceutical based on a thiosemicarbazone metal complex for positron emission tomography. In the first phase of this study were synthesized twenty-one thiosemicarbazones, derived from N(4)methyl-2 acetylpyridine and 2-pyridineformamide, as well as their metal complexes (Sn, Ga and Cu). Their cytotoxic potential were evaluated against brain and breast tumor cells in vitro. Our results showed all of them presented powerful cytotoxic and antiproliferative activities against glioblastoma multiforme and breast adenocarcinoma at very low concentrations (nanomolar range). Morphological alterations characteristic of apoptosis, such as cell shrinkage, chromatin condensation were observed. Copper chloride was used as control and has presented IC50 at milimolar range suggesting that copper complexation with thiosemicarbazone significantly increases (more than 1 million) the antitumoral effect of this metal. Due to the potent antitumoral activity of N(4)-methyl-tolyl-2-acetilpiridine derived thiosemicarbazones and the excellent properties of 64Cu (T1/2 = 12.7 hours, β+, β-, and EC decay), at the second part for this work it was developed a new imaging agent (radiopharmaceutical) for tumor detection by positron emission tomography (PET). The radiopharmaceuticals were produced in the nuclear reactor TRIGA-IPR-R1 from CDTN, via neutron capture reaction 63Cu (n,γ) 64Cu, of the copper complex N(4)-ortho-toluyl-2- acetylpyridine thiosemicarbazone (Culac). The induced specific activity was found to be 5.55 MBq /mg. After irradiation 64Culac samples were analyzed by the absorption of infrared spectroscopy (IR) to assess the structural integrity. The irradiated compound kept its structural integrity. The maintenance of 64Culac biological activity was also evaluated by MTT assay on RT2 (wild p53), T98 (mutant p53), MCF-7 (wild p53) and CAE cells (wild p53). The results showed that 64Culac kept its potent antitumural activity against all treated cells presenting IC50 values at nanomolar range. 64Culac biodistribution studies after intravenous injection in mice bearing Erlich tumor implanted in the paw, showed significant uptake in the tumor paw (tumor/skeletal muscle ratio= 6.55), 240 minutes after administration. Histopathological studies have shown mild hepatotoxicity 144 hours (6 days) after intravenous administration of 308 mg/kg of Culac. However, no lethality, behavioural, or feeding changes were observed at this dose. Our results demonstrate that the complex of copper-64 N(4)-ortho-toluyl-2- acetylpyridine thiosemicarbazone (64Culac) is a promising radiopharmaceutical for detection of solid tumors by positron emission tomography (PET).
8

A tomografia por emissão de pósitron com 18F-fluoro-desoxi-glicose (PET-FDG) na avaliação de resposta precoce à quimioterapia em pacientes portadores de linfoma de Hodgkin / Positron emission tomography with 2-[18F]-fluoro-2-desoxy-D-glucose assessing response after 2 cycles of chemotherapy in Hodgkin lymphoma

Juliano Julio Cerci 08 July 2010 (has links)
Pacientes com linfoma de Hodgkin (LH) tratados com poliquimioterpia com adriamicina, bleomicina, vincristina e doxorrubicina (ABVD) apresentam resposta terapêutica distinta. Para aprimorar a avaliação prognóstica e a abordagem terapêutica em LH objetivamos avaliar o valor prognóstico da PET-FDG após 2 ciclos de ABVD (PET2) em pacientes com LH. Foram incluídos nesse estudo prospectivo 115 pacientes com diagnóstico recente de LH no período de agosto de 2005 a dezembro de 2007. Os pacientes foram estadiados com exame clínico, laboratorial, tomografia computadorizada e PET-FDG (PET0). Todos os pacientes foram tratados com ABVD e aqueles com massa tumoral extensa foram tratados com radioterapia associada. Após dois ciclos de ABVD os pacientes foram submetidos a PET2. Nenhum tratamento foi alterado baseado na PET2. Foi avaliado o valor prognóstico dos fatores clínicos, Índice Prognóstico Internacional (IPI) e PET2 em relação à sobrevida livre de eventos (SLE) em três anos. Dos 104 pacientes que foram avaliados, 82 atingiram remissão completa e 22 pacientes apresentaram falha de tratamento durante a mediana de 36 meses de acompanhamento. A SG e SLE em três anos foi de 94,2% e 74,2% respectivamente. A SLE em três anos da PET2 positiva foi de 54,3%, enquanto da PET2 negativa foi de 90,5% (p< 0.001). Na análise de subgrupos de pacientes com estádio precoce, avançado, IPI baixo e alto risco, a PET2 também apresentou correlação estatisticamente significativa com o prognóstico. Concluímos que a PET2 é o melhor fator prognóstico independente na avaliação de pacientes com LH / Patients with Hodgkin lymphoma (HL) treated with poliquimioteraphy with adriamycin, bleomycin, vincristine and doxorubicin (ABVD) have distinct therapeutic response. In order to improve the prognostic assessment and therapeutic approach in HL we have evaluated the prognostic value of FDG-PET after 2 cycles of ABVD (PET2). Were included in this prospective study 115 patients with newly diagnosed LH in the period of August 2005 to December 2007. The patients were staged with physical examination, laboratory, CT and PET-FDG (PET0). All patients were treated with ABVD and those with extensive tumor were treated with radiotherapy associated. After two cycles of ABVD patients underwent PET2. No treatment was changed based on PET2. We assessed the prognostic value of clinical factors, international prognostic score (IPS) and PET2 in relation to event-free survival (EFS) in three years. Of the 104 patients who finalized the evaluation, 82 achieved complete remission and 22 patients experienced treatment failure during the median of 36 months of follow-up. The EFS at three years was 74.2%. EFS in three years of PET2 positive was 54.3%, while the PET2 negative was 90.5% (p <0.001). In subgroup analysis of patients with early stage, advanced, low and high risk IPS, PET2 also showed significant correlation with the prognosis. We conclude that the PET2 is the best independent prognostic factor in the evaluation of overall patients with LH, or in subgroups of early, advance; low and high risk of HL
9

Tomografia por emissão de pósitrons com sistemas PET/SPECT: Um estudo da viabilidade de quantificação / Positron Emission Tomography PET / SPECT Systems Study Viability Quantification

Pozzo, Lorena 04 March 2005 (has links)
A Tomografia por Emissão de Pósitrons (PET - Positron Emission Tomography) é uma modalidade de imagens para o diagnóstico em Medicina Nuclear. São utilizados radiofármacos emissores de pósitrons que possibilitam obter imagens que representam o processo bioquímico dessas substâncias no órgão ou tecido de interesse in vivo. São detectados, em coincidência, os fótons provenientes da aniquilação pósitron/elétron, que ocorre dentro do corpo do paciente. Esta informação é posteriormente utilizada para a reconstrução do objeto em estudo. Atualmente, existem dois tipos de equipamentos capazes de realizar estudos tomográficos por emissão de pósitrons: o dedicado e a câmara PET/SPCET. Este trabalho abordou este último tipo, que permite também a realização de exames habituais de Medicina Nuclear, que usam emissores de fótons. Existem dificuldades inerentes ao método de aquisição destas imagens que afetam a quantificação de índices ou atividade. Elas estão relacionadas ao fato de a emissão de radiação obedecer a uma distribuição de Poisson, às interações físicas da radiação com o corpo do paciente e com o detector, ao ruído devido à natureza estatística destas interações e de todo o processo de detecção, assim como à metodologia de aquisição dos exames (preparo e posicionamento do paciente, taxa de contagens etc.). Correções são propostas na literatura que não são totalmente implementadas pelos fabricantes: de espalhamento, de atenuação, de eventos aleatórios, do tempo morto, de decaimento, da resolução espacial e de outras características do equipamento. O objetivo deste trabalho foi o de realizar um estudo dos métodos aplicados por dois fabricantes, assim como algumas influências das características técnicas das câmaras PET/SPECT na obtenção do índice de SUV (Standardized Uptake Value). Para isso, dados de simuladores físicos, dispostos em várias montagens, foram obtidos com uma câmara no modo 3D e outra no modo 20. Constatou-se também que a forma das fontes usadas para calibração influencia no resultado final e impõe novos desafios para a quantificação em uma situação clínica. Por fim, no momento da quantificação, a região de interesse deve ser escolhida de acordo com aquela usada para a determinação dos coeficientes de correção e calibração. Verificou-se que é viável realizar quantificações com câmaras PET/SPECT, inclusive o índice SUV. Para tanto, além das correções citadas anteriormente, é imprescindível ter o equipamento bem ajustado, assim como a obtenção de coeficientes para normalização da sensibilidade e correção do efeito de volume parcial. / Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, randoms, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 20, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be dealt with carefully in clinical quantification. Finally, the choice of the region of interest is critical and it should be the same used to calculate the correction factors.
10

A tomografia por emissão de pósitron com 18F-fluoro-desoxi-glicose (PET-FDG) na avaliação de resposta precoce à quimioterapia em pacientes portadores de linfoma de Hodgkin / Positron emission tomography with 2-[18F]-fluoro-2-desoxy-D-glucose assessing response after 2 cycles of chemotherapy in Hodgkin lymphoma

Cerci, Juliano Julio 08 July 2010 (has links)
Pacientes com linfoma de Hodgkin (LH) tratados com poliquimioterpia com adriamicina, bleomicina, vincristina e doxorrubicina (ABVD) apresentam resposta terapêutica distinta. Para aprimorar a avaliação prognóstica e a abordagem terapêutica em LH objetivamos avaliar o valor prognóstico da PET-FDG após 2 ciclos de ABVD (PET2) em pacientes com LH. Foram incluídos nesse estudo prospectivo 115 pacientes com diagnóstico recente de LH no período de agosto de 2005 a dezembro de 2007. Os pacientes foram estadiados com exame clínico, laboratorial, tomografia computadorizada e PET-FDG (PET0). Todos os pacientes foram tratados com ABVD e aqueles com massa tumoral extensa foram tratados com radioterapia associada. Após dois ciclos de ABVD os pacientes foram submetidos a PET2. Nenhum tratamento foi alterado baseado na PET2. Foi avaliado o valor prognóstico dos fatores clínicos, Índice Prognóstico Internacional (IPI) e PET2 em relação à sobrevida livre de eventos (SLE) em três anos. Dos 104 pacientes que foram avaliados, 82 atingiram remissão completa e 22 pacientes apresentaram falha de tratamento durante a mediana de 36 meses de acompanhamento. A SG e SLE em três anos foi de 94,2% e 74,2% respectivamente. A SLE em três anos da PET2 positiva foi de 54,3%, enquanto da PET2 negativa foi de 90,5% (p< 0.001). Na análise de subgrupos de pacientes com estádio precoce, avançado, IPI baixo e alto risco, a PET2 também apresentou correlação estatisticamente significativa com o prognóstico. Concluímos que a PET2 é o melhor fator prognóstico independente na avaliação de pacientes com LH / Patients with Hodgkin lymphoma (HL) treated with poliquimioteraphy with adriamycin, bleomycin, vincristine and doxorubicin (ABVD) have distinct therapeutic response. In order to improve the prognostic assessment and therapeutic approach in HL we have evaluated the prognostic value of FDG-PET after 2 cycles of ABVD (PET2). Were included in this prospective study 115 patients with newly diagnosed LH in the period of August 2005 to December 2007. The patients were staged with physical examination, laboratory, CT and PET-FDG (PET0). All patients were treated with ABVD and those with extensive tumor were treated with radiotherapy associated. After two cycles of ABVD patients underwent PET2. No treatment was changed based on PET2. We assessed the prognostic value of clinical factors, international prognostic score (IPS) and PET2 in relation to event-free survival (EFS) in three years. Of the 104 patients who finalized the evaluation, 82 achieved complete remission and 22 patients experienced treatment failure during the median of 36 months of follow-up. The EFS at three years was 74.2%. EFS in three years of PET2 positive was 54.3%, while the PET2 negative was 90.5% (p <0.001). In subgroup analysis of patients with early stage, advanced, low and high risk IPS, PET2 also showed significant correlation with the prognosis. We conclude that the PET2 is the best independent prognostic factor in the evaluation of overall patients with LH, or in subgroups of early, advance; low and high risk of HL

Page generated in 0.518 seconds