• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 12
  • 12
  • 12
  • 12
  • 9
  • 9
  • 9
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação entre o tonômetro de rebote (Tonovet) e o novo tonômetro de aplanação (Tono-pen a via) durante curva diurna da pressão intraocular de coelhos adultos. / Comparison of a rebound (tonovet) and an new applanation tonometer (tonopen-avia) for diurnal curves of intraocular pressure in adults rabbits

Pereira, Fabiana Quartiero January 2010 (has links)
A determinação da pressão intraocular (PIO) é fundamental no exame oftálmico. Atualmente, novos tonômetros, baseados em diferentes princípios, estão sendo continuamente desenvolvidos. O objetivo deste estudo foi estabelecer os valores de referência da PIO de coelhos adultos, sem efeito de tranquilizantes, mensurada com o tonômetro de rebote (Tonovet) e o de aplanação (Tono-Pen Avia). Também foi preconizada a mensuração da PIO ao longo do dia nesta espécie e a comparação dos resultados obtidos com os dois tonômetros. A PIO foi aferida ao longo do dia (6h, 9h, 12h, 15h e 18h) em 38 coelhos (76 olhos) da raça Nova Zelândia Branca, adultos, com idade média de seis meses, machos ou fêmeas, com massa corporal média de 3,5kg. Previamente, foi realizado teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta em todos os animais. A tonometria de rebote foi realizada primeiro e, decorridos 10 minutos, foi instilado colírio anestésico e realizada a tonometria de aplanação. A PIO obtida utilizando as duas técnicas foi comparada estatisticamente. A média da PIO com o Tonovet foi de 9,51 ± 2,62 mmHg (variação de 3- 23mmHg) e 15,44 ± 2,16 mmHg (variação de 8 – 26mmHg) com o Tono-Pen Avia. Houve diferença estatística significante entre os valores obtidos com os dois tonômetros (P < 0,001). A relação entre os dois tonômetros foi representada através da equação de regressão linear: y = 0,4923x + 10,754 (y= Tonovet e x= Tono-Pen Avia). No início do dia foram registradas PIOs mais elevadas, mas a média dos valores ao longo do dia, com ambos os aparelhos, foi estatisticamente o mesmo (p = 0,086). O valor do coeficiente de correlação obtido foi r2= 0,357. Os resultados demonstram que o Tono-Pen Avia é mais variável e superestima a PIO de coelhos quando comparado ao Tonovet. Nas primeiras horas do dia, a PIO de coelhos foi mais alta que nos demais horários, independentemente do tonômetro utilizado. / The determination of intraocular pressure (IOP) is crucial in eye examination. Currently, new tonometers based on different principles are being continuously developed. The objective was to establish reference values of IOP of adults rabbits without the effect of tranquilizers, utilizing the rebound tonometer (Tonovet ) and the applanation tonometer (Tono-Pen Avia) for measurements. It also aimed to advocate the measurement of IOP throughout the day in this species and compare the results obtained with the two tonometers. The IOP was measured throughout the day (6h, 9h, 12h, 15h and 18h) in 38 New Zealand White rabbits (76 eyes), adults, males or females, with mean weight of 3.5kg and an average age of six months. Previously, the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp and direct ophthalmoscopy were performed in all animals. First, the rebound tonometry was performed and after a minimum of 10 minutes anesthetic drops were instilled and applanation tonometry was carried out. IOP obtained using the two techniques was compared by statistical analysis. The average IOP was 9.51 ± 2.62 mmHg (range 3 - 23 mmHg) and 15.44 ± 2.16 mmHg (range 8 – 26mmHg), with Tonovet and Tono-Pen Avia, respectively. Statistic significant difference between the two tonometers was (P <0.001). The linear regression equation that describes the relationship between the two tonometers was: y = 0.4923 x + 10.754 (y= Tonovet e x= Tono-Pen Avia). Earlier in the day, higher IOPs were recorded, but the average behavior of IOP throughout the day with both devices was statistically the same (p = 0.086). The value of the correlation coefficient was r2 = 0.357. The results show that the Tono-Pen Avia is more variable and overestimates the IOP of rabbits when compared with the Tonovet. In the early hours, the IOP of rabbits was higher than at other times, regardless of the tonometer used.
2

Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote

Claros Chacaltana, Flor Diana Yokoay January 2013 (has links)
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas. / The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
3

Comparação entre o tonômetro de rebote (Tonovet) e o novo tonômetro de aplanação (Tono-pen a via) durante curva diurna da pressão intraocular de coelhos adultos. / Comparison of a rebound (tonovet) and an new applanation tonometer (tonopen-avia) for diurnal curves of intraocular pressure in adults rabbits

Pereira, Fabiana Quartiero January 2010 (has links)
A determinação da pressão intraocular (PIO) é fundamental no exame oftálmico. Atualmente, novos tonômetros, baseados em diferentes princípios, estão sendo continuamente desenvolvidos. O objetivo deste estudo foi estabelecer os valores de referência da PIO de coelhos adultos, sem efeito de tranquilizantes, mensurada com o tonômetro de rebote (Tonovet) e o de aplanação (Tono-Pen Avia). Também foi preconizada a mensuração da PIO ao longo do dia nesta espécie e a comparação dos resultados obtidos com os dois tonômetros. A PIO foi aferida ao longo do dia (6h, 9h, 12h, 15h e 18h) em 38 coelhos (76 olhos) da raça Nova Zelândia Branca, adultos, com idade média de seis meses, machos ou fêmeas, com massa corporal média de 3,5kg. Previamente, foi realizado teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta em todos os animais. A tonometria de rebote foi realizada primeiro e, decorridos 10 minutos, foi instilado colírio anestésico e realizada a tonometria de aplanação. A PIO obtida utilizando as duas técnicas foi comparada estatisticamente. A média da PIO com o Tonovet foi de 9,51 ± 2,62 mmHg (variação de 3- 23mmHg) e 15,44 ± 2,16 mmHg (variação de 8 – 26mmHg) com o Tono-Pen Avia. Houve diferença estatística significante entre os valores obtidos com os dois tonômetros (P < 0,001). A relação entre os dois tonômetros foi representada através da equação de regressão linear: y = 0,4923x + 10,754 (y= Tonovet e x= Tono-Pen Avia). No início do dia foram registradas PIOs mais elevadas, mas a média dos valores ao longo do dia, com ambos os aparelhos, foi estatisticamente o mesmo (p = 0,086). O valor do coeficiente de correlação obtido foi r2= 0,357. Os resultados demonstram que o Tono-Pen Avia é mais variável e superestima a PIO de coelhos quando comparado ao Tonovet. Nas primeiras horas do dia, a PIO de coelhos foi mais alta que nos demais horários, independentemente do tonômetro utilizado. / The determination of intraocular pressure (IOP) is crucial in eye examination. Currently, new tonometers based on different principles are being continuously developed. The objective was to establish reference values of IOP of adults rabbits without the effect of tranquilizers, utilizing the rebound tonometer (Tonovet ) and the applanation tonometer (Tono-Pen Avia) for measurements. It also aimed to advocate the measurement of IOP throughout the day in this species and compare the results obtained with the two tonometers. The IOP was measured throughout the day (6h, 9h, 12h, 15h and 18h) in 38 New Zealand White rabbits (76 eyes), adults, males or females, with mean weight of 3.5kg and an average age of six months. Previously, the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp and direct ophthalmoscopy were performed in all animals. First, the rebound tonometry was performed and after a minimum of 10 minutes anesthetic drops were instilled and applanation tonometry was carried out. IOP obtained using the two techniques was compared by statistical analysis. The average IOP was 9.51 ± 2.62 mmHg (range 3 - 23 mmHg) and 15.44 ± 2.16 mmHg (range 8 – 26mmHg), with Tonovet and Tono-Pen Avia, respectively. Statistic significant difference between the two tonometers was (P <0.001). The linear regression equation that describes the relationship between the two tonometers was: y = 0.4923 x + 10.754 (y= Tonovet e x= Tono-Pen Avia). Earlier in the day, higher IOPs were recorded, but the average behavior of IOP throughout the day with both devices was statistically the same (p = 0.086). The value of the correlation coefficient was r2 = 0.357. The results show that the Tono-Pen Avia is more variable and overestimates the IOP of rabbits when compared with the Tonovet. In the early hours, the IOP of rabbits was higher than at other times, regardless of the tonometer used.
4

Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote

Claros Chacaltana, Flor Diana Yokoay January 2013 (has links)
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas. / The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
5

Comparação entre o tonômetro de rebote (Tonovet) e o novo tonômetro de aplanação (Tono-pen a via) durante curva diurna da pressão intraocular de coelhos adultos. / Comparison of a rebound (tonovet) and an new applanation tonometer (tonopen-avia) for diurnal curves of intraocular pressure in adults rabbits

Pereira, Fabiana Quartiero January 2010 (has links)
A determinação da pressão intraocular (PIO) é fundamental no exame oftálmico. Atualmente, novos tonômetros, baseados em diferentes princípios, estão sendo continuamente desenvolvidos. O objetivo deste estudo foi estabelecer os valores de referência da PIO de coelhos adultos, sem efeito de tranquilizantes, mensurada com o tonômetro de rebote (Tonovet) e o de aplanação (Tono-Pen Avia). Também foi preconizada a mensuração da PIO ao longo do dia nesta espécie e a comparação dos resultados obtidos com os dois tonômetros. A PIO foi aferida ao longo do dia (6h, 9h, 12h, 15h e 18h) em 38 coelhos (76 olhos) da raça Nova Zelândia Branca, adultos, com idade média de seis meses, machos ou fêmeas, com massa corporal média de 3,5kg. Previamente, foi realizado teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta em todos os animais. A tonometria de rebote foi realizada primeiro e, decorridos 10 minutos, foi instilado colírio anestésico e realizada a tonometria de aplanação. A PIO obtida utilizando as duas técnicas foi comparada estatisticamente. A média da PIO com o Tonovet foi de 9,51 ± 2,62 mmHg (variação de 3- 23mmHg) e 15,44 ± 2,16 mmHg (variação de 8 – 26mmHg) com o Tono-Pen Avia. Houve diferença estatística significante entre os valores obtidos com os dois tonômetros (P < 0,001). A relação entre os dois tonômetros foi representada através da equação de regressão linear: y = 0,4923x + 10,754 (y= Tonovet e x= Tono-Pen Avia). No início do dia foram registradas PIOs mais elevadas, mas a média dos valores ao longo do dia, com ambos os aparelhos, foi estatisticamente o mesmo (p = 0,086). O valor do coeficiente de correlação obtido foi r2= 0,357. Os resultados demonstram que o Tono-Pen Avia é mais variável e superestima a PIO de coelhos quando comparado ao Tonovet. Nas primeiras horas do dia, a PIO de coelhos foi mais alta que nos demais horários, independentemente do tonômetro utilizado. / The determination of intraocular pressure (IOP) is crucial in eye examination. Currently, new tonometers based on different principles are being continuously developed. The objective was to establish reference values of IOP of adults rabbits without the effect of tranquilizers, utilizing the rebound tonometer (Tonovet ) and the applanation tonometer (Tono-Pen Avia) for measurements. It also aimed to advocate the measurement of IOP throughout the day in this species and compare the results obtained with the two tonometers. The IOP was measured throughout the day (6h, 9h, 12h, 15h and 18h) in 38 New Zealand White rabbits (76 eyes), adults, males or females, with mean weight of 3.5kg and an average age of six months. Previously, the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp and direct ophthalmoscopy were performed in all animals. First, the rebound tonometry was performed and after a minimum of 10 minutes anesthetic drops were instilled and applanation tonometry was carried out. IOP obtained using the two techniques was compared by statistical analysis. The average IOP was 9.51 ± 2.62 mmHg (range 3 - 23 mmHg) and 15.44 ± 2.16 mmHg (range 8 – 26mmHg), with Tonovet and Tono-Pen Avia, respectively. Statistic significant difference between the two tonometers was (P <0.001). The linear regression equation that describes the relationship between the two tonometers was: y = 0.4923 x + 10.754 (y= Tonovet e x= Tono-Pen Avia). Earlier in the day, higher IOPs were recorded, but the average behavior of IOP throughout the day with both devices was statistically the same (p = 0.086). The value of the correlation coefficient was r2 = 0.357. The results show that the Tono-Pen Avia is more variable and overestimates the IOP of rabbits when compared with the Tonovet. In the early hours, the IOP of rabbits was higher than at other times, regardless of the tonometer used.
6

Avaliação da pressão intraocular em chinchilas (chinchilla Lanigera) de diferentes faixas etárias utilizando tonometria de rebote

Claros Chacaltana, Flor Diana Yokoay January 2013 (has links)
A aferição da pressão intraocular (PIO) é fundamental durante o exame oftálmico. Objetivou-se estabelecer os valores de referência da PIO de chinchilas de diferentes faixas etárias utilizando o tonômetro de rebote. A PIO foi aferida ao longo do dia às 7, 12 e 19 horas utilizando o tonômetro de rebote (Tonovet®). As chinchilas foram subdivididas em três grupos com 12 animais cada, considerando as idades, designados por GI (animais com idade entre dois a seis meses), GII (com idade entre 20 e 34 meses) e GIII (animais com idade entre 37 e 135 meses). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos os animais. O valor médio da pressão intraocular encontrado foi 2,49 ± 0,56 mmHg, os valores médios para o grupo I foi de 2,47±0,581 mmHg, no grupo II de 2,47±0,581 mmHg e no grupo III de 2,51±0,531 mmHg. Não foram encontradas diferenças significativas entre a idade e a PIO (P = 0,756). Não foram encontradas diferenças significativas entre as horas do dia e a PIO (P = 0,415). Não foram encontradas diferenças significativas entre os sexos (P = 0,857). Os valores da PIO em chinchilas não sofrem alterações decorrentes do sexo e da idade dos animais. Não ocorre influência do ritmo circadiano na PIO de chinchilas. / The assessment of intraocular pressure (IOP) is essential for the ocular examination. The purpose of this study was to establish reference values of intraocular pressure chinchillas (Chinchilla lanigera) of different age groups. Thirty-six Chinchillas were divided in three groups of 12 animals each, considering the ages designated by GI (animals aged two to six months), GII (aged between 20 and 34 months) and GIII (animals aged between 37 and 135 months). Intraocular pressure was measured at 7, 12 and 19 hours. Tear production was measured, fluorescein test, slit-lamp biomicroscopy and indirect ophthalmoscopy in all animals and IOP was measured using the rebound tonometer (Tono Vet®) set on the P (undefined species) setting, with measurements obtained from each eye. No abnormalities were found on ophthalmic examination. The mean (±SD) of IOP was 2.49 ± 0.56 mmHg, with a range of 2-4 mmHg. The mean (±SD) of IOP for group I, II and III were 2.47 ± 0.581 mmHg, 2.47 ± 0.581 mmHg and 2,51 ± 0.531 mmHg, respectively. No significant differences were found between age and IOP and no significant differences were found between the hours of day and IOP. No significant differences were found between the genders. The IOP in chinchillas is unchanged between genders and age of the animals. The circadian rhythm is not influenced by IOP in chinchillas.
7

Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote

Ghiggi, Eduardo January 2016 (has links)
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas. / The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.
8

Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote

Ghiggi, Eduardo January 2016 (has links)
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas. / The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.
9

Estudo comparativo entre a tonometria de rebote e a tonometria de aplanação em equinos da raça crioula (Equus cabbalus)

Andrade, Maria Cristina Caldart de January 2011 (has links)
A aferição da pressão intraocular (PIO) é importante para o diagnóstico e acompanhamento de doenças oculares. Métodos fidedignos para quantificar a PIO de maneira acurada têm sido buscados. Com o aparecimento de tonômetros portáteis, a avaliação da pressão intraocular em equinos tem se intensificado e os diferentes princípios de aferição têm sido comparados. Este estudo objetivou a comparação entre a tonometria de aplanação, realizada com o Tono-Pen Avia®, e tonometria de rebote, realizada com o Tonovet®, em equinos da raça Crioula. Além disso, a utilização, ou não, do cachimbo como método de contenção também foi comparada e submetida à análise estatística. Foram avaliados 30 cavalos com idades entre dois e 20 anos, machos ou fêmeas. Exame oftálmico prévio foi realizado com teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia direta. A tonometria de aplanação foi realizada, no mínimo, 30 minutos após a tonometria de rebote. A pressão intraocular média do Tonovet® foi maior, 36,82 ± 5,91mmHg com cachimbo e 30,04 ± 3,19mmHg sem. A do Tono-Pen Avia® foi de 26,43 ± 5,48 mmHg com cachimbo e 23,10 ±4,01mmHg sem. Todos os resultados diferiram estatisticamente entre si. Quando comparados os sexos, o Tono-Pen Avia® não mostrou diferenças, enquanto o Tonovet® mostrou pressões maiores para cavalos castrados e garanhões, e menores para éguas (p<0,001) com a utilização do cachimbo. Não há correlação entre a idade dos cavalos e os valores de PIO, independente do aparelho (p > 0,05). Os valores da PIO com o Tonovet® foram maiores do que os obtidos com o Tono-Pen Avia®. A contenção dos animais com cachimbo eleva a pressão intraocular em equinos. / Intraocular pressure evaluation is important for diagnosis and control of ophthalmic diseases. Accurate methods to quantify intraocular pressure have been searched. With the development of handheld tonometers, equine intraocular pressure evaluation has been intensified and the different principles of measurement have been compared. The objective of this study was to compare the applanation tonometry, taken with the Tono- Pen Avia® and the rebound tonometry, taken with the Tonovet® in adult “crioulo” breed horses. The age, gender and the use of upper lip twitch as a restraint method was also surveyed and submitted to statistical analysis. Thirty horses, aged two to 20, male or female were evaluated. A previous ophthalmic examination was performed with Schirmer tear test, fluoresceine test, slit lamp biomicroscopy and direct ophthalmoscopy in all animals. Applanation tonometry was performed, at least, 30 minutes after rebound tonometry. Intraocular pressure mean values measured with the Tonovet® was higher, 36,82±5,91mmHg with the lip twitch and 30,04±3,19mmHg without. Tonopen Avia® mean values were 26,43±5,48mmHg with the lip twitch and 23,10±4,1mmHg without. All results was statistical different between themselves. When genders were compared the Tono-Pen Avia® revealed no difference, however the Tonovet® showed higher pressures for male horses (p‹0,001) with the use of lip twitch. There was no correlation between age and intraocular pressure in “crioulo” horses, regardless of the equipment tested (p›0,05). Intraocular pressure mean values measured with the Tonove®t were higher than those obtained with the Tono-Pen Avia®. The restraint of animals with upper lip twitch increases equine intraocular pressure.
10

Curva diária de pressão intraocular em porquinhos da índia (Cavia porcellus) de diferentes faixas etárias com tonometria de rebote

Ghiggi, Eduardo January 2016 (has links)
A aferição da pressão intraocular (PIO) é essencial para o exame oftálmico. Objetivou-se estabelecer os valores da curva diária da PIO de porquinhos da índia de diferentes faixas etárias com tonômetro de rebote. A PIO foi aferida às 6, 12, 18 e 24 horas utilizando o tonômetro de rebote (Tonovet®). Os porquinhos da índia foram subdivididos em dois grupos com 10 animais no grupo I e 4 animais no grupo II, considerando as idades, designados por GI (animais entre 2 a 3 meses de idade) e GII (animais entre 2 a 3 anos de idade). Previamente, foram realizados teste da lágrima de Schirmer, prova da fluoresceína, biomicroscopia com lâmpada de fenda e oftalmoscopia indireta em todos animais. O valor médio da pressão intraocular foi de 12,0 ± 1,83 mmHg. Foram encontradas diferenças significativas entres as idades, sendo que os valores médios para o grupo I foram 11,63 ± 0,29 mmHg, e para o grupo II foram 12,82 ± 0,45mmHg (P= 0,0295). Não foram encontradas diferenças entre ambos os olhos (P= 0,7454). Não foram encontradas diferenças significativas nos valores da PIO relacionadas ao sexo (P= 0,1858). Os valores da PIO em porquinhos da índia tiveram alteração nas horas avaliadas. Com base nos resultados obtidos foi possível concluir que os valores da PIO em porquinhos da índia da sofrem alterações ao longo do dia. Os menores valores de pressão intraocular ocorreram às 18 horas. / The measuring of intraocular pressure (IOP) it is essential for the ophthalmic evaluation; the aim of this study was establish the values of the IOP diurnal curve of guinea pigs with different ages using the rebound tonometer (Tonovet®). The animals were divided according to the age in two groups, Group I (GI) constituted with 10 guinea pigs aged between 2 -3 moths, and Group II (GII), 4 animals with 2 -3 years of old. Previously the Schirmer tear test, fluorescein test, biomicroscopy with slit lamp, and direct optalmoscopy were performed on all animals. The men value of IOP was 12.0±0.34 mmHg. Statistical difference were found between ages (mean GI 11.64 ± 0.29 mmHg, and GII 12.83 ± 0.45mmHg), did not have statistical difference related with gender (P= 0.1858) or between eyes (P= 0.7454). In conclusion the guinea pigs had alteration of IOP true the day, the values of IOP are higher in the morning period, decrease true the day and at the night period haves an elevation again.

Page generated in 0.0591 seconds