• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 5
  • 2
  • Tagged with
  • 30
  • 30
  • 17
  • 15
  • 15
  • 12
  • 8
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação das condições higiênico-sanitárias dos serviços de alimentação de um shopping center do município de Porto Alegre/RS / Evaluation of the hygienic status of food services located in a shopping mall from Porto Alegre, Brazil

Wingert, Carine January 2012 (has links)
Diversas condições durante as etapas de produção dos alimentos podem levar à introdução de micro-organismos patogênicos nas refeições. Esse fato pode ser relevante nos serviços de alimentação localizados em shopping centers pela limitada área física, número de equipamentos insuficientes e volume de refeições servidas. O objetivo do presente estudo foi avaliar esse tipo de estabelecimento quanto ao cumprimento de boas práticas e verificar a presença de matéria orgânica e contaminação bacteriana residual em refrigeradores que haviam sido submetidos à limpeza de rotina. Vinte estabelecimentos localizados em um shopping center de Porto Alegre foram incluídos no estudo. Em cada estabelecimento foi aplicada a Lista de Verificação em Boas Práticas para Serviços de Alimentação prevista na Portaria nº 78 de 28 de Janeiro de 2009 (CEVS) e foram colhidas três amostras com intervalo mensal da parede interna do refrigerador no dia subsequente à limpeza de rotina. As amostras foram avaliadas pelo sistema Clean Trace (3M), quanto à presença de Listeria sp., Coliformes Totais e Escherichia coli. Os dados resultantes da aplicação da Lista de Verificação apontaram que 55% dos estabelecimentos não atingiram a pontuação mínima (>75%) para serem considerados satisfatórios. Em 95% (57/60) das amostras colhidas nos refrigeradores, demonstrou-se a presença de matéria orgânica residual. Já as análises microbiológicas apontaram ausência de Listeria sp., presença de de Coliformes Totais e E. coli em 8,3% e 1,6% das amostras, respectivamente. Não houve associação entre a classificação do estabelecimento (satisfatório/insatisfatório) e a presença de matéria orgânica residual ou Coliformes Totais nos refrigeradores. Estes resultados demonstram a necessidade de constante revisão e monitoramento dos processos de higienização de equipamentos em serviços de alimentação. / Several conditions during all stages of food production can lead to the introduction of pathogenic micro-organisms in food. This fact may be relevant in the food service located in shopping malls by limited physical area, insufficient number of equipment and volume of meals served. The aim of this study was to evaluate this type of establishment for compliance with good practices and verify the presence of organic matter and residual bacterial contamination in refrigerators that had been submitted to routine cleaning. Twenty establishments located in a shopping center from Porto Alegre were included in the study. In each establishment a Checklist for Good Practice for Food Services, provided by Resoltuion No. 78 published on January 28th 2009 (CEVS), was aplied, and three samples were collected at monthly intervals from the inner wall of the refrigerator on the day following the routine cleaning. The samples were evaluated by the Clean Trace system (3M) for the presence of Listeria sp., Total Coliforms and Escherichia coli. The data resulting from application of the Checklist showed that 55% of establishments didn’t attained the minimum score (> 75%) to be classified satisfactory. From de samples taken on the refrigerator’s inner wall, 95% (57/60) demonstrated the presence of residual organic. Nevertheless, microbiological analyzes showed absence of Listeria sp., and isolation of Total Coliforms and E. coli in 8.3% and 1.6% of the samples, respectively. There was no association between the classification of the establishment (satisfactory / unsatisfactory) and the presence of residual organic matter or total coliform in the refrigerator. The results demonstrate the need for constant review and monitoring and improvement of sanitizing procedures of equipment in food service.
22

Fatores relacionados ao uso e qualidade bacteriológica e físico-química das águas de poços e minas em propriedades rurais e peri-urbanas no município de Botucatu

Rolim, Renata Guimarães [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:16:23Z : No. of bitstreams: 1 rolim_rg_me_botfmvz.pdf: 619306 bytes, checksum: 9eda35e64a6ec67af8363a7d9517136b (MD5) / Universidade Estadual Paulista (UNESP) / Os objetivos deste trabalho foram os de realizar um levantamento de propriedades que utilizavam água de poços e minas, localizados tanto na área rural quanto na peri-urbana, no município de Botucatu, além de verificar a qualidade da água em função de seu uso e detectar a percepção dos proprietários em relação a importância de sua qualidade em termos de saúde pública. A metodologia usada para essa pesquisa consistiu de entrevistas com os proprietários dos poços e minas, por meio de questionário englobando aspectos da propriedade, da fonte e tipo de tratamento, da colheita e análise da água. Foram estudadas 28 fontes, sendo 22 poços e 6 minas. Foram colhidas três amostras de cada fonte em semanas consecutivas, e realizadas análises bacteriológicas de coliformes totais e termotolerantes, através da técnica dos tubos múltiplos e análises químicas de cobre, fosfato e organoclorados. Os resultados obtidos pelas análises revelaram um índice de contaminação por coliformes totais de 93% e de coliformes termotolerantes em 82% nas fontes analisadas, concluindo-se que estavam impróprias para consumo, de acordo com a legislação vigente, a Portaria nº 518 do Ministério da Saúde, que estabelece os procedimentos para o controle e a vigilância da qualidade da água para consumo humano e seu padrão de potabilidade. Não foram detectados teores de cobre e organoclorados nas amostras... / The objectives of this work had been to carry a survey of properties that used water of wells and mines, located in the agricultural area and in the peri-urban one, in the city of Botucatu, besides verifying the quality of the water in function of its use and detecting the perception of the proprietors in relation the importance of its quality in terms of public health. The used methodology for this research consisted of interviews with the proprietors of the wells and mines, by means of questionnaire including aspects of the property, the spring, type of treatment, the harvest and analysis of the water. 28 sources had been studied, being 22 wells and 6 mines. Three samples of each source had been harvested, in consecutive weeks, and they were carried through bacteriological analysis of total and termotolerante coliforms through the multiple tube fermentations technique and chemical analysis of copper, phosphate and organochlorines. The results gotten for the analysis had disclosed an index of contamination for total coliform of 93% and termotolerant coliform in 82% in the analyzed sources, concluding that they were improper for consumption, in accordance with the current law, Portaria nº 518 of the Health department that it establishes the procedures for the control and the monitoring of the quality of the water for human consumption and its potable standard...
23

Avaliação das condições higiênico-sanitárias dos serviços de alimentação de um shopping center do município de Porto Alegre/RS / Evaluation of the hygienic status of food services located in a shopping mall from Porto Alegre, Brazil

Wingert, Carine January 2012 (has links)
Diversas condições durante as etapas de produção dos alimentos podem levar à introdução de micro-organismos patogênicos nas refeições. Esse fato pode ser relevante nos serviços de alimentação localizados em shopping centers pela limitada área física, número de equipamentos insuficientes e volume de refeições servidas. O objetivo do presente estudo foi avaliar esse tipo de estabelecimento quanto ao cumprimento de boas práticas e verificar a presença de matéria orgânica e contaminação bacteriana residual em refrigeradores que haviam sido submetidos à limpeza de rotina. Vinte estabelecimentos localizados em um shopping center de Porto Alegre foram incluídos no estudo. Em cada estabelecimento foi aplicada a Lista de Verificação em Boas Práticas para Serviços de Alimentação prevista na Portaria nº 78 de 28 de Janeiro de 2009 (CEVS) e foram colhidas três amostras com intervalo mensal da parede interna do refrigerador no dia subsequente à limpeza de rotina. As amostras foram avaliadas pelo sistema Clean Trace (3M), quanto à presença de Listeria sp., Coliformes Totais e Escherichia coli. Os dados resultantes da aplicação da Lista de Verificação apontaram que 55% dos estabelecimentos não atingiram a pontuação mínima (>75%) para serem considerados satisfatórios. Em 95% (57/60) das amostras colhidas nos refrigeradores, demonstrou-se a presença de matéria orgânica residual. Já as análises microbiológicas apontaram ausência de Listeria sp., presença de de Coliformes Totais e E. coli em 8,3% e 1,6% das amostras, respectivamente. Não houve associação entre a classificação do estabelecimento (satisfatório/insatisfatório) e a presença de matéria orgânica residual ou Coliformes Totais nos refrigeradores. Estes resultados demonstram a necessidade de constante revisão e monitoramento dos processos de higienização de equipamentos em serviços de alimentação. / Several conditions during all stages of food production can lead to the introduction of pathogenic micro-organisms in food. This fact may be relevant in the food service located in shopping malls by limited physical area, insufficient number of equipment and volume of meals served. The aim of this study was to evaluate this type of establishment for compliance with good practices and verify the presence of organic matter and residual bacterial contamination in refrigerators that had been submitted to routine cleaning. Twenty establishments located in a shopping center from Porto Alegre were included in the study. In each establishment a Checklist for Good Practice for Food Services, provided by Resoltuion No. 78 published on January 28th 2009 (CEVS), was aplied, and three samples were collected at monthly intervals from the inner wall of the refrigerator on the day following the routine cleaning. The samples were evaluated by the Clean Trace system (3M) for the presence of Listeria sp., Total Coliforms and Escherichia coli. The data resulting from application of the Checklist showed that 55% of establishments didn’t attained the minimum score (> 75%) to be classified satisfactory. From de samples taken on the refrigerator’s inner wall, 95% (57/60) demonstrated the presence of residual organic. Nevertheless, microbiological analyzes showed absence of Listeria sp., and isolation of Total Coliforms and E. coli in 8.3% and 1.6% of the samples, respectively. There was no association between the classification of the establishment (satisfactory / unsatisfactory) and the presence of residual organic matter or total coliform in the refrigerator. The results demonstrate the need for constant review and monitoring and improvement of sanitizing procedures of equipment in food service.
24

Avaliação das condições higiênico-sanitárias dos serviços de alimentação de um shopping center do município de Porto Alegre/RS / Evaluation of the hygienic status of food services located in a shopping mall from Porto Alegre, Brazil

Wingert, Carine January 2012 (has links)
Diversas condições durante as etapas de produção dos alimentos podem levar à introdução de micro-organismos patogênicos nas refeições. Esse fato pode ser relevante nos serviços de alimentação localizados em shopping centers pela limitada área física, número de equipamentos insuficientes e volume de refeições servidas. O objetivo do presente estudo foi avaliar esse tipo de estabelecimento quanto ao cumprimento de boas práticas e verificar a presença de matéria orgânica e contaminação bacteriana residual em refrigeradores que haviam sido submetidos à limpeza de rotina. Vinte estabelecimentos localizados em um shopping center de Porto Alegre foram incluídos no estudo. Em cada estabelecimento foi aplicada a Lista de Verificação em Boas Práticas para Serviços de Alimentação prevista na Portaria nº 78 de 28 de Janeiro de 2009 (CEVS) e foram colhidas três amostras com intervalo mensal da parede interna do refrigerador no dia subsequente à limpeza de rotina. As amostras foram avaliadas pelo sistema Clean Trace (3M), quanto à presença de Listeria sp., Coliformes Totais e Escherichia coli. Os dados resultantes da aplicação da Lista de Verificação apontaram que 55% dos estabelecimentos não atingiram a pontuação mínima (>75%) para serem considerados satisfatórios. Em 95% (57/60) das amostras colhidas nos refrigeradores, demonstrou-se a presença de matéria orgânica residual. Já as análises microbiológicas apontaram ausência de Listeria sp., presença de de Coliformes Totais e E. coli em 8,3% e 1,6% das amostras, respectivamente. Não houve associação entre a classificação do estabelecimento (satisfatório/insatisfatório) e a presença de matéria orgânica residual ou Coliformes Totais nos refrigeradores. Estes resultados demonstram a necessidade de constante revisão e monitoramento dos processos de higienização de equipamentos em serviços de alimentação. / Several conditions during all stages of food production can lead to the introduction of pathogenic micro-organisms in food. This fact may be relevant in the food service located in shopping malls by limited physical area, insufficient number of equipment and volume of meals served. The aim of this study was to evaluate this type of establishment for compliance with good practices and verify the presence of organic matter and residual bacterial contamination in refrigerators that had been submitted to routine cleaning. Twenty establishments located in a shopping center from Porto Alegre were included in the study. In each establishment a Checklist for Good Practice for Food Services, provided by Resoltuion No. 78 published on January 28th 2009 (CEVS), was aplied, and three samples were collected at monthly intervals from the inner wall of the refrigerator on the day following the routine cleaning. The samples were evaluated by the Clean Trace system (3M) for the presence of Listeria sp., Total Coliforms and Escherichia coli. The data resulting from application of the Checklist showed that 55% of establishments didn’t attained the minimum score (> 75%) to be classified satisfactory. From de samples taken on the refrigerator’s inner wall, 95% (57/60) demonstrated the presence of residual organic. Nevertheless, microbiological analyzes showed absence of Listeria sp., and isolation of Total Coliforms and E. coli in 8.3% and 1.6% of the samples, respectively. There was no association between the classification of the establishment (satisfactory / unsatisfactory) and the presence of residual organic matter or total coliform in the refrigerator. The results demonstrate the need for constant review and monitoring and improvement of sanitizing procedures of equipment in food service.
25

Avaliação da resistência de microrganismos patogênicos à desinfecção sequencial com ozônio-radiação ultravioleta e cloro-radiação ultravioleta / Resistance evaluation of pathogenic microorganisms to sequential disinfection with ozone-ultraviolet radiation and chlorine-ultraviolet radiation

Juliana Lourenção 05 June 2009 (has links)
A remoção de microrganismos patogênicos através da desinfecção é uma necessidade para diminuir a incidência de doenças na população humana relacionadas com poluição fecal. A desinfecção sequencial tem grande potencial na remoção de microrganismos, quando comparada com a desinfecção convencional (um desinfetante). Neste trabalho buscou-se comparar a resistência de microrganismos indicadores de bactérias - E. coli e coliformes totais - e bactérias esporuladas - Clostridium perfringens quanto à desinfecção sequencial empregando cloro seguido de radiação ultravioleta e ozônio seguido de radiação ultravioleta; e à desinfecção convencional utilizando-se os mesmos desinfetantes aplicados individualmente em esgoto sanitário tratado previamente em reator UASB. Os ensaios foram realizados em batelada. As dosagens de cloro aplicadas foram de 10, 20 e 30 mg\'CL IND.2\'/L; de ozônio foram de 5,6; 11 e 16,5 mg\'O IND.3\'/L, ambos para os tempos de contato 10, 20 e 30 minutos. Na desinfecção sequencial com cloro foram aplicadas as doses de 1, 5 e 10 Wh/\'M POT.3\' de radiação UV; com ozônio, as doses de radiação foram variadas de 0,5 a 10 Wh/\'M POT.3\'. Na desinfecção sequencial de cloro-UV, foram removidos 2,5 e 5,2 log de C. perfringens e coliformes totais, respectivamente contra 1,5 e 4,2 log na desinfecção convencional para os mesmos microrganismos. Na desinfecção com cloro, a ordem decrescente de resistência foi: C. perfringens > coliformes totais > E. coli. Para ozônio seguido de UV, C. perfringens apresentou maior resistência e, em alguns ensaios, E. coli apresentou-se mais resistente que coliformes totais. A ação do ozônio mostrou-se notável para a melhoria da qualidade do esgoto tratado avaliada pela diminuição das concentrações de sólidos suspensos totais, sólidos totais, absorbância em comprimento de onda de 254 nm e da DQO, diferentemente do esgoto clorado no qual ocorreu o aumento nos valores destas variáveis físico-químicas. A ação da radiação ultravioleta foi potencializada quando aplicada sequencialmente ao cloro e ao ozônio. / The removal of pathogenic microorganisms through disinfection is a necessity to decrease the incidence of diseases in the human population related to fecal pollution. Sequential disinfection has a great potential on the removal of microorganisms when compared to conventional disinfection (single disinfectant). This work compared the resistance of indicators microorganisms of bacteria - E. coli and total coliforms - and spore-forming bacteria - Clostridium perfringens concerning the sequential and conventional disinfections. The sequential disinfection initially employed chlorine followed by ultraviolet radiation and ozone followed by ultraviolet radiation. The conventional disinfection utilized the same disinfectants individually applied in sanitary sewage previously treated in UASB reactor. The tests were made in batch. The chlorine dosages applied were 10, 20 and 30 mg\'CL IND.2\'/L; ozone were 5,6; 11 and 16,5 mg\'O IND.3\'/L, both for the contact times 10, 20 and 30 minutes. In the sequential disinfection with chlorine dosages of 1, 5 and 10 Wh/\'M POT.3\' of UV radiation were applied; with ozone, the dosages of radiation varied from 0,5 to 10 Wh/\'M POT.3\'. In the sequential disinfection with UV-chlorine were inactived 2,5 and 5,2 log of C. perfringens and total coliforms respectively, against 1,5 and 4,2 log in the conventional disinfection for the same microorganisms. In the chlorine disinfection, the decreasing resistance order was: C. perfringens > total coliforms > E. coli. In the ozone disinfection followed by UV, C. perfringens manifested more resistance and, in some assays, E. coli was more resistant than total coliforms. The action of ozone was outstanding for the improvement of treated sewage quality assessed by the decreasing of total suspended solids concentration, total solids absorbance at a wavelength of 254 nm and of DQO, differently from the chlorine sewage in which occurred an increase of the values of the physical-chemical variables. The ultraviolet radiation action was potentiated when sequentially applied to chlorine and to ozone.
26

The fate of microbial contaminants in the subsurface with a South African case study

Rajkumar, Yasmin January 2009 (has links)
Magister Scientiae - MSc / The time bound agenda of the Millennium Development Goals (MDG's) aims at reducing poverty, extending gender equality and advancing opportunities for health and education by addressing current and future water resource and sanitation needs. In many rural areas of South Africa, the cost implication of routing surface water supplies and providing water borne sewerage may far exceed the budgets of local water service authorities. This has resulted in a major thrust in service provision via localised sources, mainly boreholes and springs as well as on site sanitation options. Whilst the National Water Act (Act 36 of 1998) mandates the South African government to provide potable water to all citizens in an equitable manner, this needs to be balanced against the preservation of the country’s water resources both quantitatively and qualitatively to ensure sustainability. It is imperative that this fine balance between protection and effecting societal demands and economic development through large-scale water provision be maintained, as successful strategising will be resultant of integrated social, economic and environmental issues especially in economically developing countries. In order to fulfil the mandate of the NWA, policies and strategies for effective protection and use of groundwater resources have been drawn up and are in the process of being drawn up by the national Department of Water Affairs and Forestry (DWAF). The major scope of research in this thesis stems from feasibility studies commissioned by the DWAF for the implementation of a groundwater protection zoning policy for the management and protection of groundwater resource quality. The research work focuses on specifically the microbiological zone of protection and attempts to determine the fate of various pathogens that emanate from on site sanitation facilities as they move through the subsurface. The research was predominantly proposed as a desktop collation and analysis of existing published data however; it was later decided to include a local case study site. / South Africa
27

Inativação de indicadores patogênicos em sistemas combinados de tratamento e pré-desinfecção de esgoto sanitário / Inactivation of pathogens tracers in combined systems for sanitary sewer treatment and pre-disinfection

Monaco, Patrícia Bilotta 07 April 2006 (has links)
A proposta apresentada se baseia na introdução de um estágio intermediário de desinfecção previamento ao tratamento biológico visando intensificar os efeitos do estágio seguinte destinado à desinfecção convencional. Para estudo de caso foram aplicadas as técnicas de ozonização e radiação UV combinadas em instalações piloto que simulam duas condições seqüenciais de desinfecção. O desempenho do método proposto foi avaliado através de exames microbiológicos de amostras do efluente anaeróbio previa e posteriormente à desinfecção, utilizando indicadores de contaminação por bactérias (Escherichia coli e coliformes totais), vírus (colifagos) e protozoário (Clostridium perfringens). Os resultados obtidos no sistema combinado pré-desinfecção/desinfecção revelaram eficiência de inativação superior quando comparada ao procedimento convencional. Nas análises de E.coli, por exemplo, a aplicação de apenas 1 mg de ozônio/L ou 51 mW de radiação/'CM POT.2', na primeira etapa de desinfecção, foi suficiente para se alcançar 1 log acima do valor correspondente ao método convencional. Mesmo indicadores mais resistentes como C. perfringens apresentaram redução da fração N/No da ordem de 1 log em relação ao método proposto. Além disso, estes níveis de inativação foram alcançados mesmo sob a influência de elevada concentração de SST, SSV e DQO na entrada na unidade piloto destinada à pré-desinfecção. Entre as seqüências de experimentação investigadas ('O IND.3'/'O IND.3', 'O IND.3'/UV, UV/'O IND.3' e UV/UV) não foram observadas grandes variações. De modo semelhante, os resultados revelaram que a relação N/No, para os indivíduos submetidos ao sistema combinado, não foi afetada pelo aumento no tempo de exposição ao agente inativante ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120s). Considerando as baixas dosagens de 'O IND.3' e UV aplicadas na primeira etapa, somada às condições limitadas de desempenho do sistema real examinado, os níveis de inativação alcançados sugerem grande potencialidade de utilização do método alternativo proposto, comprovando sua viabilidade técnica / The present proposition is based on the introduction of an intermediate disinfection stage before the biological treatment, in order to intensify the effects of the next stage employed in conventional disinfection. Studies were performed using combined ozonization and UV radiation techniques, in a model installation that simulates two sequential disinfection conditions. The performance of the method was evaluated using microbiological exams of samples taken from the anaerobic effluent before and after the disinfection. Bacterial (Escherichia coli and total coliforms), viral (coliphages) and protozoan (Clostridium perfringens contamination tracers were used in such exams. Results obtained by combining pre-disinfection and disinfection reveal superior inactivation efficiency as compared to the conventional procedure. For example, in the E. coli analysis the application of only 1 mg of ozone/L or 51 mW/'CM POT.2' of radiation in the first disinfection stage was enough for achieving 1 log above the convention method. Even more resistant tracers, such as C. perfringens, showed aproximatelly 1 log of reduction in the N/No fraction in the proposed method. Besides, these inactivation levels were achieved even for high concentrations of SST, SSV and DQO in the entrance of the pre-disinfection unit. No significant variations were observed among the disinfection sequences ('O IND.3'/'O IND.3','O IND.3'/UV,UV/'O IND.3', and UV/UV). Similarly, the results showed that the N/No relation, for individuals submitted to the combined system, was not affected by the increase of the exposition time to the inactivation agent ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120 s). Taking into account the low dosages of 'O IND.3' and UV applied in the first stage and the limited performance conditions of the real system, the achieved inactivation levels suggest a great potential for the alternative method proposed, demonstrating its technical viability
28

Inativação de indicadores patogênicos em sistemas combinados de tratamento e pré-desinfecção de esgoto sanitário / Inactivation of pathogens tracers in combined systems for sanitary sewer treatment and pre-disinfection

Patrícia Bilotta Monaco 07 April 2006 (has links)
A proposta apresentada se baseia na introdução de um estágio intermediário de desinfecção previamento ao tratamento biológico visando intensificar os efeitos do estágio seguinte destinado à desinfecção convencional. Para estudo de caso foram aplicadas as técnicas de ozonização e radiação UV combinadas em instalações piloto que simulam duas condições seqüenciais de desinfecção. O desempenho do método proposto foi avaliado através de exames microbiológicos de amostras do efluente anaeróbio previa e posteriormente à desinfecção, utilizando indicadores de contaminação por bactérias (Escherichia coli e coliformes totais), vírus (colifagos) e protozoário (Clostridium perfringens). Os resultados obtidos no sistema combinado pré-desinfecção/desinfecção revelaram eficiência de inativação superior quando comparada ao procedimento convencional. Nas análises de E.coli, por exemplo, a aplicação de apenas 1 mg de ozônio/L ou 51 mW de radiação/'CM POT.2', na primeira etapa de desinfecção, foi suficiente para se alcançar 1 log acima do valor correspondente ao método convencional. Mesmo indicadores mais resistentes como C. perfringens apresentaram redução da fração N/No da ordem de 1 log em relação ao método proposto. Além disso, estes níveis de inativação foram alcançados mesmo sob a influência de elevada concentração de SST, SSV e DQO na entrada na unidade piloto destinada à pré-desinfecção. Entre as seqüências de experimentação investigadas ('O IND.3'/'O IND.3', 'O IND.3'/UV, UV/'O IND.3' e UV/UV) não foram observadas grandes variações. De modo semelhante, os resultados revelaram que a relação N/No, para os indivíduos submetidos ao sistema combinado, não foi afetada pelo aumento no tempo de exposição ao agente inativante ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120s). Considerando as baixas dosagens de 'O IND.3' e UV aplicadas na primeira etapa, somada às condições limitadas de desempenho do sistema real examinado, os níveis de inativação alcançados sugerem grande potencialidade de utilização do método alternativo proposto, comprovando sua viabilidade técnica / The present proposition is based on the introduction of an intermediate disinfection stage before the biological treatment, in order to intensify the effects of the next stage employed in conventional disinfection. Studies were performed using combined ozonization and UV radiation techniques, in a model installation that simulates two sequential disinfection conditions. The performance of the method was evaluated using microbiological exams of samples taken from the anaerobic effluent before and after the disinfection. Bacterial (Escherichia coli and total coliforms), viral (coliphages) and protozoan (Clostridium perfringens contamination tracers were used in such exams. Results obtained by combining pre-disinfection and disinfection reveal superior inactivation efficiency as compared to the conventional procedure. For example, in the E. coli analysis the application of only 1 mg of ozone/L or 51 mW/'CM POT.2' of radiation in the first disinfection stage was enough for achieving 1 log above the convention method. Even more resistant tracers, such as C. perfringens, showed aproximatelly 1 log of reduction in the N/No fraction in the proposed method. Besides, these inactivation levels were achieved even for high concentrations of SST, SSV and DQO in the entrance of the pre-disinfection unit. No significant variations were observed among the disinfection sequences ('O IND.3'/'O IND.3','O IND.3'/UV,UV/'O IND.3', and UV/UV). Similarly, the results showed that the N/No relation, for individuals submitted to the combined system, was not affected by the increase of the exposition time to the inactivation agent ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120 s). Taking into account the low dosages of 'O IND.3' and UV applied in the first stage and the limited performance conditions of the real system, the achieved inactivation levels suggest a great potential for the alternative method proposed, demonstrating its technical viability
29

SÉRIES TEMPORAIS E MODELOS NUMÉRICOS PREDITIVOS COMO FERRAMENTAS DE AUXÍLIO AO GERENCIAMENTO COSTEIRO INTEGRADO DA ILHA DO MARANHÃO, BRASIL. / TIME SERIES AND PREDICTIVE NUMERICAL MODELS AS TOOLS TO AID THE INTEGRATED COASTAL MANAGEMENT OF THE ISLAND OF MARANHÃO (BRAZIL).

Siqueira, Laurinda Fernanda Saldanha 18 March 2010 (has links)
Made available in DSpace on 2016-08-19T18:20:35Z (GMT). No. of bitstreams: 1 LAURINDA FERNANDA SALDANHA SIQUEIRA.pdf: 940563 bytes, checksum: 997451038c9761fcacf436b4488d38e5 (MD5) Previous issue date: 2010-03-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / What has been observed on the beaches of the island of Maranhao (Brazil) is an intense process of urbanization started from the 70's, not always accompanied by urban space structuring and planning, causing many environmental problems, mainly with respect to environmental sanitation. In coastal areas, the challenge of integrated management is mainly to harmonize urban development with conservation and sustainable use. Whereas improve the quality of decisions in the management of sustainability, are necessary closer links between the results of sustainability monitoring and the policy responses of decision makers. Under the hypothesis that increasing levels of total coliform in the beaches water, as indicative of contamination by domestic sewage and therefore a poor urban planning, are results of the performance variables of urban sprawl and sanitation indicators, had the objective to propose tools to aid the integrated management and sustainability in the form of time series and numerical predictive models of levels of total coliform bacteria in water from the beaches of Ponta da Areia, São Marcos, Calhau, Olho d Água and Araçagy, coastline of the island of Maranhao (Brazil). To this end, a study was performed documental and field research to obtain data about urban sprawl, sanitation and water quality of the beaches studied for construction and analysis of time series of total coliform in water, study the correlations between variables urban expansion and sanitation on the levels of total coliforms and construction and proposal of numerical models based in correlations found and peculiarities of the beaches studied. The results indicate confirmation of research hypothesis. The analysis of time series indicated a significant increase in levels of total coliform in the water of the beaches studied, being more significant on the beaches Calhau, São Marcos and Olho d Água, and less significant on the beaches of Ponta da Areia and Araçagy. The amplitude of the seasonal behavior of these levels was variable, subject to seasonal multiplicative factors responsible for checking the variability, this strike was obtained which allowed equations to calculate them for each time period. The variables explained most of the growth of total coliforms in water and are used in the construction of predictive numerical models, was urban population, population density, number of households connected to the sewer system, number of households with inadequate sewage, water pH and release numbers in natura sewage on the beaches, associated characteristics of each beach in the form of seasonal factors obtained by the time series analysis. This study is an indirect measurement and should be used as an alternative tool in the sustainable management of the area studied and evaluation of public policies to the management of water resources. The research merit on integrated coastal management was to represent reverse direction to the your proposed goals and sustainability of the coastline of the island of Maranhão (Brazil). / O que se tem observado nas praias da Ilha do Maranhão (Brasil) é um processo intenso de urbanização iniciado a partir da década de 70, nem sempre acompanhado por uma estruturação e planejamento do espaço urbano, ocasionando inúmeros problemas ambientais, principalmente no que concerne ao saneamento ambiental. Nas áreas costeiras o desafio do gerenciamento integrado está, sobretudo, em harmonizar o desenvolvimento urbano com a conservação e o uso sustentável. Neste âmbito, considerando a melhoria da qualidade das decisões em gestão da sustentabilidade, são necessárias relações mais estreitas entre os resultados do monitoramento da sustentabilidade e as respostas políticas dos tomadores de decisão. Sob a hipótese de que os níveis crescentes de coliformes totais na água das praias, como indicativos de contaminação por esgotos domésticos e, por conseguinte de um planejamento urbano deficiente, são resultado da atuação de variáveis de expansão urbana e de indicadores de saneamento básico, teve-se o objetivo propor ferramentas de auxilio ao gerenciamento costeiro integrado na forma de séries temporais e modelos numéricos preditivos dos níveis de coliformes totais na água das praias da Ponta da Areia, São Marcos, Calhau, Olho d água e Araçagy, da orla marítima da Ilha do Maranhão (Brasil). Neste intuito, foi realizada pesquisa documental e em campo para obtenção de dados referentes à expansão urbana, ao saneamento básico e à qualidade da água das praias estudadas, para construção e análise das séries temporais de coliformes totais na água, estudo das correlações entre as variáveis de expansão urbana e saneamento básico sobre os níveis de coliformes totais e para construção e proposição de modelos numéricos com base nas correlações identificadas e nas peculiaridades das praias estudadas. Os resultados indicam confirmação da hipótese da pesquisa. A análise das séries temporais indicou haver tendência crescente nos níveis de coliformes totais na água das praias em estudo, sendo mais significativa nas praias do Calhau, São Marcos e Olho d Água, e menos significativa nas praias da Ponta da Areia e Araçagy. A amplitude da sazonalidade do comportamento destes níveis foi variável, condicionada a fatores sazonais multiplicativos responsáveis por conferir a variabilidade, neste intento obteve-se equações que permitiram calculá-los para cada período de tempo. As variáveis que mais explicaram o crescimento dos níveis de coliformes totais na água, sendo utilizadas na construção dos modelos numéricos preditivos, foram população urbana, densidade populacional, número de domicílios ligados a rede coletora de esgotos, número de domicílios com estruturas inadequadas de esgotamento sanitário, pH da água e números de lançamento de esgoto in natura nas praias, associadas as peculiaridades de cada praia na forma de fatores sazonais obtidos pela análise das séries temporais. Há de se ter em mente que este estudo é uma aferição indireta e que deve ser utilizada como instrumento subsidiário na gestão sustentável do espaço estudado e na avaliação das políticas públicas traçadas na área de gerenciamento dos recursos hídricos. O mérito da pesquisa diante o gerenciamento costeiro integrado foi verificar o retrocesso em direção às suas metas e à sustentabilidade da orla marítima da Ilha do Maranhão (Brasil).
30

Interface água e saúde: correlação com atividades agroindustriais desenvolvidas em um perímetro irrigado no Semiárido Paraibano. / Interface water and health: correlation with agribusiness activities developed in a Semiarid Irrigated Perimeter in Paraiba.

SANTOS, Romércia Batista dos. 16 May 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-05-16T16:02:56Z No. of bitstreams: 1 ROMÉRCIA BATISTA DOS SANTOS - DISSERTAÇÃO PPGSA PROFISSIONAL 2013..pdf: 1113569 bytes, checksum: 29bd7b553a65415a734895bc13bc037a (MD5) / Made available in DSpace on 2018-05-16T16:02:56Z (GMT). No. of bitstreams: 1 ROMÉRCIA BATISTA DOS SANTOS - DISSERTAÇÃO PPGSA PROFISSIONAL 2013..pdf: 1113569 bytes, checksum: 29bd7b553a65415a734895bc13bc037a (MD5) Previous issue date: 2013-12-20 / O presente trabalho propôs correlacionar atividades agroindustriais com a saúde humana e ambiental, tendo o Perímetro Irrigado de São Gonçalo-PB, como local de estudo. Para isto analisou-se a água bruta e tratada oriunda do referido perímetro, através de parâmetros físico-químicos e microbiológicos, como objeto maior de investigação. A pesquisa caracteriza-se de natureza quantitativa, qualitativa e descritiva. Foram georreferenciados oito pontos de amostragem, sendo que quatro pontos foram de água bruta e quatro de água tratada. As coletas foram realizadas em 2012, durante seis meses, considerando abril, maio e junho como período de inverno e, outubro, novembro e dezembro como época de seca. Fez-se também um levantamento dos indicadores básicos das condições sanitárias e socioambientais que refletem diretamente na saúde humana e no ecossistema. Os resultados físicoquímicos e microbiológicos foram avaliados com base nas legislações vigentes. Assim, foi possível constatar que tanto as amostras da água bruta e tratada, em relação aos atributos físico-químicos, estes se mantiveram dentro dos limites permitidos (Res. CONAMA 375/05 e Portaria MS nº2914/11, respectivamente). Os resultados microbiológicos constataram presença de coliformes, de presença total e termotolerantes para as amostras de água bruta, em ambos os períodos de inverno e verão. O critério de balneabilidade para estas mesmas águas apresentaram aspectos satisfatórios para o ponto A3 e A4 (ver pontos de análise) e impróprias para os pontos A6 e A8 (Res. CONAMA 274/2000). Assim, as águas tratadas revelaram focos de contaminação microbiológica em todos os pontos, observadas as delimitações da Portaria MS 2914/2011, pela presença de coliformes totais. As amostras de águas tratadas revelaram que nos núcleos habitacionais II e III (NHII-2 e NHIII-2) apontaram valores de Número Mais Provável (NMP) de coliformes totais e termotolerantes elevados, acreditando-se que tal contaminação esteja atribuída à má manutenção da rede hidráulica, e/ou higienização ineficiente. É importante informar que a média de chuvas no ano de 2012, período da pesquisa, foi abaixo do esperado, contribuindo para um decréscimo significativo em relação ao volume total em metros cúbicos (m³) do açude de São Gonçalo. Tal situação é preocupante, pois, a diminuição das águas é um indicador de eutrofização. Após análise, foi possível concluir que tais situações, como, por exemplo, o abastecimento e tratamento de água, destino dos dejetos e dos resíduos sólidos, refletem uma condição de prédisposição da população as doenças como também podem comprometer as atividades agroindustriais desenvolvidas no perímetro irrigado em estudo. / This paper proposed agribusiness activities correlate with human and environmental health, and the Irrigated Perimeter of São Gonçalo - PB, as a study. For this we analyzed the raw and treated water coming from said perimeter, through physical, chemical and microbiological parameters, such as increased under investigation. The research is characterized quantitative, qualitative and descriptive nature. Eight sampling were geocoded, and four points were raw water and treated water four. The collections were made in 2012, for six months, for April, May and June as period and reverse, October, November and December as the dry season. And he made a survey of the basic indicators of health and environmental conditions that directly influence human health and the ecosystem. The physico-chemical and microbiological outcomes were assessed based on the current legislation. Thus, it was found that both samples of raw water and treated in relation to physico-chemical properties, these remained within permitted limits (CONAMA Resolution 375/05 and MS Portaria No. 2914/11, respectively). The microbiological results found presence of coliforms, total and thermotolerant presence for raw water samples, in both winter and summer periods. The criteria for bathing waters showed satisfactory these same aspects for the A3 and A4 point (see point analysis) and unfit for A6 and A8 points (CONAMA Resolution 274/2000). Thus, the treated water showed foci of microbial contamination at all points, observing the boundaries of the MS 2914/2011, by the presence of total coliforms. Samples of treated water showed that the housing units II and III (and NHIII-2 NHII-2) showed values of more than Probable Number (MPN) of total coliforms and thermotolerant high, it is believed that such contamination is attributed to poor maintenance the hydraulic network, and / or inefficient cleaning. It is important to mention that the average rainfall in 2012, survey period, was lower than expected, contributing to a significant decrease in the total volume in cubic meters ( m³ ) Açude of São Gonçalo. This situation is worrying because, with the decrease of water promotes the process of eutrophication. After analysis of the indicators, it was concluded that such situations, for example, the supply and treatment of water, Sewage facilities and solid waste, reflect a pre-condition to the population as diseases can also compromise the agribusiness activities developed in the irrigated area under study.

Page generated in 0.1801 seconds