• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • Tagged with
  • 56
  • 56
  • 50
  • 43
  • 17
  • 16
  • 15
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliações histológica e histomorfométrica de implantes osseointegráveis de titânio com superfície anodizada e revestida por Ca e P / Histological and Histomorphometric analysis of Ti implants with surfaces modified by anodic spark deposition in Ca and P

Gustavo Cavalcanti de Albuquerque 20 December 2010 (has links)
Estudos de modificações de superfície de implantes de Ti têm atraído a atenção dos pesquisadores por existir grande interesse em tratamentos que possam acelerar o processo fisiológico de reparo do tecido ósseo em contato com o Ti. Avaliações in vitro mostraram que superfícies de Ti obtidas por modificação físicoquímica como a anodização (anodic spark discharge ASD) podem representar uma boa alternativa para melhorar a osseointegração de implantes. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de mandíbula de cães a implantes osseointegráveis de Ti com superfície modificada por duplo ataque ácido (AE), por anodização em solução de íons cálcio e fosfato (ASD-AK) e anodização em solução de silício, cálcio e fosfato seguido por ataque alcalino em NaOH (SiB-Na). Para isso dez cães foram submetidos a exodontia dos pré-molares 12 semanas antes das instalação dos implantes. Os animais foram sacrificados no período de 5 e 8 semanas (cinco por período) e os segmentos ósseos contendo os implantes foram processados. Foram avaliados os efeitos dos tratamentos de superfície na (1) porcentagem de contato direto osso-implante, (2) formação óssea entre as roscas do implante e (3) formação óssea à distância da superfície do implante. Os resultados mostraram que todos os tratamentos (AE, ASD-AK e SiB-Na) permitiram formação óssea em contato direto e adjacente à superfície de Ti sem apresentar nenhum diferença qualitativa e quantitativa no padrão de reparo ósseo. Portanto, esses tratamentos deveriam ser avaliados clinicamente na reabilitação implanto-suportada de pacientes parcial ou totalmente edêntulos. / Surface modification of Ti have been attracted the attention of the researchers for existing great interest in treatments that can speed up the physiological process of repair of the bone contact. Aiming to improve the osseointegration of Ti implants several surface treatments have been proposed including those obtained by anodic spark deposition technique (anodic spark discharge ASD). This treatment allows to developing a thin and porous surface layer enriched with selected ions from the electrochemical solution. This study was designed to analyze bone repair adjacent to and in contact with Ti implants with surfaces modified by acid etching (AE) and anodic spark deposition (ASD). Surface modification of Ti implants was carried out by three methods: AE, ASD in calcium and phosphate solution (ASD-AK), and ASD in calcium, phosphate and silicon solution followed by alkali etching in NaOH (SiB-Na). Ten mongrel dogs were submitted to premolar extraction and after 12 weeks AE, BS, and SiB-Na self-screw Ti implants were placed into edentulous areas. Animals were killed at 3 and 8 weeks (five per period) and bone fragments with implants harvested and processed to obtain thin ground sections. Histomorphometric analysis was carried out to determine the bone-implant contact (BIC), bone area between threads (BABT), and bone area adjacent to threads (BAAT). The results had shown that all the treatments (AE, ASD-AK and SiB-Na) had allowed bone formation in direct and adjacent contact to the surface, without qualitative and quantitative difference in the standard of bone repair. Therefore, these surface treatments would have clinically to be evaluated in the implant-supported rehabilitation of total edentulous or patients partial.
22

Caracterização de filme vítreo, sinterizado com diferentes ciclos térmicos, depositado sobre substrato de Y-TZP e sua resistência de união imediata e após termociclagem a cimentos resinosos / Characterization of a glass film, sintered under different thermal cycles, and its bond strength to resin cements immediately and after thermocycling

Fernando Taddeo 10 September 2013 (has links)
A zircônia estabilizada por ítria (Y-TZP) apresenta excelentes propriedades mecânicas; entretanto, sua microestrutura cristalina inerte faz com que tratamentos aplicados em porcelanas e vitrocerâmicas, como condicionamento com ácido fluorídrico e aplicação de compostos silânicos, sejam ineficazes para obter união aos cimentos resinosos. Neste trabalho, propõe-se uma alternativa para aumentar a reatividade da Y-TZP a cimentos resinosos por meio de um processo de modificação da superfície através da deposição de um filme vítreo. O objetivo deste estudo é, portanto, caracterizar um filme vítreo, sinterizado com diferentes ciclos térmicos, após deposição sobre Y-TZP (YZ 20/19, VITA Blocks Zahnfabrik, Bad Saackingen, Germany) e avaliar a resistência de união imediata e após ciclagem térmica (10.000 ciclos 5 e 55°C) a dois cimentos resinosos (Relyx Arc, 3M/ESPE, St. Paul, MN, USA e Rely-X U200 3M/ESPE, Neuss, Germany). A caracterização do filme foi efetuada por meio de microscopia eletrônica de varredura, para avaliar a morfologia; EDS (Espectroscopia por dispersão de energia), para estabelecer uma análise qualitativa e semi-quantitativa dos elementos químicos presentes e mensuração do ângulo de contato. Foram propostas as seguintes condições experimentais na superfície da YTZP: deposição dos filmes sinterizados à 700°C, 900°C ou ciclo de sinterização para o auto glaze; aplicação do primer contendo MDP (Alloy Primer, Kuraray Medical Inc, Kurashiki, Okayama, Japan); e silicatização da superfície (sistema Rocatec Soft, 3M/ESPE, St. Paul, MN, USA). Após o ensaio mecânico, o padrão de fratura foi avaliado por meio de microscopia óptica. Para os dados obtidos, o traço de Pillai (p = 0,00) mostrou que o tipo de tratamento empregado tem um efeito significativo sobre a resistência de união. Para determinar a diferença entre os grupos estudados foi aplicado um teste de comparações múltiplas (Tukey). O filme 900 apresentou maior resistência de união imediata (42,2 MPa), sendo este valor estatisticamente superior a silicatização (35,5 MPa) e MDP (28,0 MPa). Os resultados obtidos após termociclagem, mostram que o filme 900 novamente apresentou maior resistência de união (36,8 MPa) e também foi estatisticamente superior ao MDP (16,1 MPa) e silicatização (27,3MPa). A análise em microscópio estereoscópico demonstrou um padrão de fratura predominantemente coesiva na resina para microtração imediata para os grupos com deposição do filme vítreo e silicatizados. Para o MDP, o padrão de fratura foi, na sua maioria, do tipo mista. O ângulo de contato medido imediatamente após os tratamentos de superfície apresentou-se menor para os grupos com filme e silicatização e manteve-se com baixos valores somente para os grupos com filme após limpeza com álcool absoluto. A análise por EDS das superfícies dos filmes indicou a presença de silício nos diversos pontos analisados. Concluiu-se, deste modo, que a deposição do filme vítreo mostrou-se como um meio eficiente para promover uma forte e durável união com da Y-TZP com os cimentos resinosos, independente da temperatura de sinterização utilizada. / The yttria stabilized zirconia (Y- TZP) has excellent mechanical properties, however its inert crystalline microstructure makes treatments applied in porcelain and glass ceramics, such as hydrofluoric acid etching and application of silane compounds, are ineffective for the union resin cements. In this work, we propose an alternative to increase the reactivity of the Y- TZP resin cement by a process of surface modification by depositing a glass film. The aim of this study is therefore to characterize a glass film, sintered with different thermal cycles, after deposition on Y- TZP (YZ - 20/19, VITA Blocks Zahnfabrik, Bad Saackingen, Germany) and to evaluate the bond strength immediately after thermocycling (10.000 cycles 5 and 55°C) to two resin cements (Relyx Arc, 3M/ESPE, St. Paul, MN, USA and Rely - X U200 3M/ESPE, Neuss, Germany). The characterization of the glass film was performed by means of scanning electron microscopy to assess the morphology, EDS (Energy Dispersive Spectroscopy), to establish a qualitative and semi-quantitative chemical elements and measuring the contact angle. Been proposed the following experimental conditions on the surface of YTZP: deposition of films sintering at 700°C, 900°C or sintering cycle for VM9 self glaze; primer containing MDP (Alloy Primer, Kuraray Medical Inc., Okayama, Okayama, Japan) and silica coating surface (Rocatec Soft, 3M/ESPE, St. Paul, MN, USA) . After mechanical testing, the fracture pattern was evaluated by light microscopy. For data, the trace of Pillai (p = 0.00) showed that the type of treatment used has a significant effect on the bond strength. To determine the difference between groups was applied multiple comparison test (Tukey). The 900 film showed higher bond strength immediately (42.2 MPa), and this value was statistically superior to silica coat (35.5 MPa) and MDP (28.0 MPa). The results obtained after thermocycling, show that 900 film again showed highest bond strength (36.8 MPa) and was also statistically superior to MDP (16.1 MPa) and silica coating (27.3 MPa). The analysis in stereoscopic microscopes showed a pattern of predominantly cohesive fracture in the resin for immediate microtensile for groups with film deposition and silica coat. In the MDP, the fracture pattern was mostly of the mixed type. The contact angle measured immediately after the surface treatments was lower for groups with film and silica coat and remained with low values only for groups with film after cleaning with absolute alcohol. Analysis by EDS surfaces of the films indicated the presence of silicon at the various points analyzed. It was concluded therefore that the glass film deposition proved to be an efficient way to promote a strong and durable bond with Y- TZP with resin cements, regardless of sintering temperature used.
23

Avaliação da resposta do tecido ósseo tipo IV a implantes osseointegráveis de titânio com diferentes tratamentos de superfície / Evaluation of type IV bone tissue response to titanium implants with different surface treatments.

Gileade Pereira Freitas 26 June 2014 (has links)
As alterações de superfície dos implantes de titânio (Ti) influenciam funções celulares e formação de tecido adjacente aos mesmos, mas é controverso se tais alterações trariam vantagens quando esses implantes fossem colocados em tecido ósseo de baixa qualidade. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de baixa qualidade (tipo IV) a implantes de Ti com diferentes tratamentos de superfície. Para isso, implantes de Ti com superfície nanotexturizada (Ti-Nano), microtexturizada (Ti-Porous) e sem tratamento de superfície (Ti-Usinado) foram implantados em tíbias de coelhos. Após duas e seis semanas, o tecido ósseo formado ao redor dos implantes foi avaliado em cortes histológicos por desgaste e histomorfometricamente foram avaliados: a porcentagem de contato ossoimplante (BIC), porcentagem de área de osso mineralizado formado entre as espiras do implante (BABT), porcentagem da área de osso formada na área espelho (BAMA). Vários outros parâmetros morfométricos foram avaliados a partir de imagens e reconstruções tridimensionais obtidos por microtomografia. Ao final de seis semanas, foi avaliado o torque de remoção. Os resultados foram submetidos à análise de variância (ANOVA) com dois fatores de variação (tratamento de superfície e tempo de implantação) seguido do teste de Tukey (p≤0,05). Apesar de algumas diferenças estatisticamente significantes para alguns dos parâmetros morfométricos, tais diferenças não são biologicamente importantes para que pudessem ser atribuídas aos tratamentos de superfície. Tanto que, histologicamente não se observou diferença nos padrões de formação óssea ou tipo de osso formado que pudesse ser associado aos tratamentos de superfície e o torque de remoção também não foi afetado pelos tratamentos. Em conclusão, esses resultados mostraram que os tratamentos de superfície, embora sejam na escala micrométrica ou nanométrica, não induzem repostas do tecido ósseo tipo IV diferentes daquelas induzidas por superfícies sem tratamento. / Some alterations in titanium (Ti) implant surfaces influence cell functions and tissue formation in areas adjacent to the implants, but it is controversial whether these changes would bring advantages when these implants were placed in bone of poor quality. The aim of this study was to evaluate the response of poor quality bone tissue (type IV) to Ti implants with different surface treatments. For this, Ti implants with nanotextured surface (Ti-Nano), microtextured (Ti-Porous) and without surface treatment (Ti-Machined) were implanted into tibias of rabbits. After two and six weeks, the bone tissue around the implants was assessed in undecalcified histological sections and histomorphometrical analysis to evaluate: the percentage of bone-implant contact (BIC), percentage of the area of mineralized bone formed between threads (BABT), the percentage area of bone formed in the mirror area (BAMA). Several other morphometric parameters were evaluated from images and three-dimensional reconstructions obtained by microtomography. At the end of six weeks the removal torque was evaluated. The results were subjected to analysis of variance (ANOVA) with two factors of variation (surface treatment and time) followed by Tukey test (p≤0.05). Despite some statistically significant differences for some of the morphometric parameters, such differences are not biologically important and they could not be attributed to the surface treatments. In keeping with this, histological analysis failed to show any difference in bone formation that could be associated to the surface treatments and removal torque was not affected by treatments either. In conclusion, these results showed that the surface treatments, irrespective of being on the micrometer or nanometer scale, do not induce responses of type IV bone tissue different from those induced by untreated surfaces.
24

Influência do método de aplicação do glaze e de sua associação ao ácido fluorídrico na superfície de uma cerâmica Y-TZP

Malta, Natália Veloso 09 June 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-13T18:22:43Z No. of bitstreams: 1 nataliavelosomalta.pdf: 1376730 bytes, checksum: cdeb2bd74c09e4792776e296bd5f7f42 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T10:32:11Z (GMT) No. of bitstreams: 1 nataliavelosomalta.pdf: 1376730 bytes, checksum: cdeb2bd74c09e4792776e296bd5f7f42 (MD5) / Made available in DSpace on 2017-01-31T10:32:11Z (GMT). No. of bitstreams: 1 nataliavelosomalta.pdf: 1376730 bytes, checksum: cdeb2bd74c09e4792776e296bd5f7f42 (MD5) Previous issue date: 2016-06-09 / O objetivo desse estudo foi avaliar, a influência de duas diferentes técnicas de aplicação de glaze (pincél e spray) sobre a morfologia de superfície de uma cerâmica Y-TZP (IPS e.maxR®ZirCAD (IvoclarVivadent) antes e após a aplicação do ácido fluorídrico. Foram confeccionados 20 corpos de prova a partir de 4 blocos cerâmicos de zircônia parcialmente estabilizada por ítria pré-sinterizados, que foram divididos em 5 grupos (n=4) de acordo com o tratamento de superfície recebido: C= controle (nenhum tratamento de superfície); S: glaze spray VITA AKZENT( Vita Zanhfabrik )P/L: glaze pó/líquido VITA AKZENT (Vita Zanhfabrik,) S+HF: S + condicionamento com ácido fluorídrico 10% (HF)(FGM) (1min); P/L + HF: P/L + condicionamento com HF 10% (1min). As amostras forma então submetidas ao seguintes testes: 1) goniometria, para ánalise do ângulo de contato e da energia de superfície; 2) análise dos dados de rugosidade (Ra) por meio de um perfilômetro óptico digital; 3)identificação das fases cristalinas do material pela Difratometria de Raios X; 4) análise dos elementos químicos presentes no material cerâmico por Microscopia e espectrometria por energia dispersiva (EDS); 5) análise da superfície por meio de microscopia eletrônica de varredura (MEV). Os resultados demonstraram que: 1) a superfície das amostras tratadas com o glaze pó/líquido foram as que apresentaram uma camada mais espessa de glaze, com superfícies menos rugosas; 2)o grupo que recebeu o tratamento com o glaze pó/líquido foi o que apresentou a maior energia de superfície (69,83mN/m), e os demais grupos apresentaram elevados valores de ângulos de contato; 3) o tratamento térmico de vitrificação não causou alterações de fases na estrutura da zircônia; 4)As imagens de perfilometria e MEV revelaram um padrão irregular de disposição do glaze após o condicionamento com HF 10%, e um alto conteúdo de sílica foi observado somente nos grupos P/L e P/L + HF. O estudo concluiu que a utilização do glaze pó/líquido pela técnica do pincel promoveu uma maior padronização da camada de glaze e foi método de tratamento de superfície que apresentou uma maior energia de superfície e um maior conteúdo vítreo. Pelas imagens de microscopia, pode-se observar que a aplicação do ácido fluorídrico a 10% criou microretenções sobre a camada de glaze pó-liquido que podem favorecer a adesão a esta superfície. / The present study evaluated qualitatively the influence of two different types of glaze (brush and spray) on the surface of Y-TZP ceramics (IPS e.maxR® ZirCAD (IvoclarVivadent,) before and after use of hydrofluoric acid. Twenty specimens were made from 4 zirconia ceramic blocks partially stabilized by pre-sintered yttria, which were divided into 5 groups (n=5) according to the surface treatment received: C = Zirconia (control) (no surface treatment); S: glaze spray VITA AKZENT; P/L: glaze powder/liquid VITA AKZENT, S+HF: S + etching with hidrofluoridric acid 10% (HF)(FGM) (1min); P/L + HF: P/L + etching with HF 10% (1min).Samples were then subjected to the following tests: 1) Goniometry for analysis of the contact angle and the surface energy ; 2) Analysis of roughness data (Ra) by means of a digital optical profilometer; 3) Identification of the crystalline phases of the material by X-ray diffraction;4) Analysis of the chemical elements present in the ceramic material by microscopy and energy dispersive spectrometry (EDS); 5) analysis of the surface after each surface treatment by means of scanning electron microscopy (SEM).Partial results showed that: 1) The surface of the samples treated with glaze powder/liquid showed a thicker layer of glaze with less rough surfaces; 2) the group receiving treatment with glaze powder/liquid presented higher surface energy (69,83mN/m), while the other groups showed high values of contact angles; 3) thermal treatment of vitrification did not change the phases of zirconia surface; 4) The SEM and profilometry images revealed a glaze irregular pattern layout after etching with 10% HF, and a high silica content was observed only in GP / L and GP / L + HF groups. The study concluded that use of the glaze powder / liquid by brush technique promoted a greater standardization of the glaze layer and this surface treatment method was the one that showed a higher surface energy and a higher glassy content. For microscopy images, it can be seen that the application of hydrofluoric acid 10% created micro retentions on the glaze powder-liquid layer that can promote adhesion to this surface.
25

Avaliação do efeito de diferentes lasers de alta intensidade no tratamento de superfície da cerâmica Y-TZP pré e pós sinterização / Effect evaluation of different high-intensity lasers on the surface treatment of Y-TZP ceramic before and after sintering

Silva, Amanda Verna e 12 September 2011 (has links)
O objetivo deste estudo foi avaliar os efeitos dos lasers de Nd:YAG, CO2 e Er,Cr:YSGG no tratamento de superfície da cerâmica Y-TZP antes e depois da sinterização final, por meio de Microscopia Eletrônica de Varredura (MEV), mensuração da rugosidade de superfície (Ra) e teste de resistência adesiva por microcisalhamento (RAD). Para tanto, barras de Y-TZP foram confeccionadas e distribuídas entre as 3 fases do experimento, sendo as duas primeiras fases seletivas para a identificação dos parâmetros lasers a serem utilizados na fase 3 de análise da RAD. Na fase 1 MEV - foram testados parâmetros que variavam entre 50 e 100 mJ para o laser de Nd:YAG, 2 a 4W para o laser de CO2 e 1 a 3,5W para o laser de Er,Cr:YSGG, testados antes ou após a sinterização da Y-TZP. Observou-se que a maioria dos tratamentos foram capazes de promover alterações na cerâmica com diferentes intensidades dependendo do parâmetro utilizado. Para a fase 2 Ra foram selecionados apenas os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG aplicados antes da sinterização da cerâmica, sendo que cada laser foi avaliado individualmente e comparados ao tratamento de superfície com o sistema Rocatec. Os tratamentos com os maiores valores de Ra foram: para o laser de Nd:YAG - 1,6W-20Hz (11.623±3,419) e para o laser de Er,Cr:YSGG - 3W (6,051±1,991). O sistema Rocatec apresentou os menores valores de rugosidade (1,297±0,026). Para a fase 3 do estudo RAD foram selecionados os parâmetros que apresentaram os maiores valores de Ra para cada laser, além do parâmetro com características favoráveis à adesão observado na fase 1 MEV. Sendo assim, o teste de microcisalhamento foi realizado entre a cerâmica Y-TZP tratada com os lasers antes da sinterização final, nos parâmetros de 1,6W e 1,2W para o laser de Nd:YAG e 3W para o laser de Er,Cr:YSGG; e com o sistema Rocatec, utilizando-se dois cimentos resinosos de dupla ativação (Panavia e RelyX U100). A análise estatística ANOVA Split-Plot dos dados de RAD obtidos revelou que não houve diferença estatística entre os cimentos estudados. Porém, no fator tratamentos de superfície observou-se que os maiores valores de RAD foram obtidos para o sistema Rocatec (20,92±3,4MPa). Os dois parâmetros utilizados para o laser de Nd:YAG foram semelhantes entre si com valores de RAD intermediários (1,2W=9,79±4 MPa e 1,6W=11,35±3,64 MPa) e o tratamento com o laser de Er,Cr:YSGG apresentou os menores valores de RAD (1,43±1,21MPa). Pôde-se concluir que os tratamentos de superfície com todos os lasers testados nos parâmetros de irradiação após a sinterização, provocaram danos à cerâmica Y-TZP. Os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG antes da sinterização, apesar de apresentarem características micromorfológicas sugestivas de aumento da área de superfície, não foram suficientes para aumentar a resistência adesiva entre a Y-TZP e os cimentos resinosos testados. / The aim of this study was to evaluate the effects of Nd:YAG, CO2 and Er,Cr:YSGG lasers on the surface treatment of Y-TZP ceramic before and after the final sintering by means of Scanning Electron Microscope (SEM), surface roughness measurement (Ra) and microshear bond strength adhesive resistance test (RAD). In order to do so, Y-TZP bars were produced and distributed among the three experimental phases, being the two first ones selective in what regards identifying parameters for the lasers used in phase 3 of the RAD analysis. In phase 1 SEM parameters varying from 50 to 100 mJ were tested for the Nd:YAG laser, from 2 to 4W for the CO2 laser and from 1 to 3,5W for the Er,Cr:YSGG laser, either before or after the Y-TZP sintering. It was observed that most treatments were able to promote changes in the ceramic with varied intensity according to the parameter used. In phase 2 Ra only treatments with Nd:YAG and Er,Cr:YSGG lasers applied before ceramic sintering were selected, and each laser was individually evaluated and compared to the surface treatment with Rocatec system. The treatments which had the highest Ra values were: 1,6W-20Hz (11.623±3,419) for the Nd:YAG laser and 3W (6,051±1,991) for Er,Cr:YSGG. Rocatec system showed the lowest roughness levels (1,297±0,026). As for phase 3 of the study RAD the highest Ra parameters for each laser were selected as well as the parameter with favorable characteristics to adherence observed in phase 1 SEM. Therefore, the microshear bond strength test was done not only in the Y-TZP ceramic treated with lasers before the final sintering (using 1,6W and 1,2W parameters for the Nd:YAG laser and 3W for Er,Cr:YSGG), but also in the Rocatec system, making use of two double activation resin cements (Panavia e RelyX U100). The ANOVA Split-Plot statistical analysis of the RAD data showed that there were no statistical variations concerning the studied cements. However, in what regards the surface treatments, it was observed that the highest RAD values were obtained for the Rocatec system (20,92±3,4MPa). Both parameters used for the Nd:YAG laser were similar, presenting intermediate RAD values (1,2W=9,79±4 and 1,6W=11,35±3,64 MPa). The treatment which used Er,Cr:YSGG laser presented the lowest RAD values (1,43±1,21MPa). It was possible to conclude that surface treatments with all tested lasers in the irradiation parameters after sintering caused damage to the Y-TZP ceramic. Treatments making use of Nd:YAG and Er,Cr:YSGG lasers before the sintering were not enough in order to increase the adhesive resistance between Y-TZP and the resin cements tested, even though they presented micromorphological characteristics that indicated growth in the surface area.
26

Avaliação do efeito de diferentes lasers de alta intensidade no tratamento de superfície da cerâmica Y-TZP pré e pós sinterização / Effect evaluation of different high-intensity lasers on the surface treatment of Y-TZP ceramic before and after sintering

Amanda Verna e Silva 12 September 2011 (has links)
O objetivo deste estudo foi avaliar os efeitos dos lasers de Nd:YAG, CO2 e Er,Cr:YSGG no tratamento de superfície da cerâmica Y-TZP antes e depois da sinterização final, por meio de Microscopia Eletrônica de Varredura (MEV), mensuração da rugosidade de superfície (Ra) e teste de resistência adesiva por microcisalhamento (RAD). Para tanto, barras de Y-TZP foram confeccionadas e distribuídas entre as 3 fases do experimento, sendo as duas primeiras fases seletivas para a identificação dos parâmetros lasers a serem utilizados na fase 3 de análise da RAD. Na fase 1 MEV - foram testados parâmetros que variavam entre 50 e 100 mJ para o laser de Nd:YAG, 2 a 4W para o laser de CO2 e 1 a 3,5W para o laser de Er,Cr:YSGG, testados antes ou após a sinterização da Y-TZP. Observou-se que a maioria dos tratamentos foram capazes de promover alterações na cerâmica com diferentes intensidades dependendo do parâmetro utilizado. Para a fase 2 Ra foram selecionados apenas os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG aplicados antes da sinterização da cerâmica, sendo que cada laser foi avaliado individualmente e comparados ao tratamento de superfície com o sistema Rocatec. Os tratamentos com os maiores valores de Ra foram: para o laser de Nd:YAG - 1,6W-20Hz (11.623±3,419) e para o laser de Er,Cr:YSGG - 3W (6,051±1,991). O sistema Rocatec apresentou os menores valores de rugosidade (1,297±0,026). Para a fase 3 do estudo RAD foram selecionados os parâmetros que apresentaram os maiores valores de Ra para cada laser, além do parâmetro com características favoráveis à adesão observado na fase 1 MEV. Sendo assim, o teste de microcisalhamento foi realizado entre a cerâmica Y-TZP tratada com os lasers antes da sinterização final, nos parâmetros de 1,6W e 1,2W para o laser de Nd:YAG e 3W para o laser de Er,Cr:YSGG; e com o sistema Rocatec, utilizando-se dois cimentos resinosos de dupla ativação (Panavia e RelyX U100). A análise estatística ANOVA Split-Plot dos dados de RAD obtidos revelou que não houve diferença estatística entre os cimentos estudados. Porém, no fator tratamentos de superfície observou-se que os maiores valores de RAD foram obtidos para o sistema Rocatec (20,92±3,4MPa). Os dois parâmetros utilizados para o laser de Nd:YAG foram semelhantes entre si com valores de RAD intermediários (1,2W=9,79±4 MPa e 1,6W=11,35±3,64 MPa) e o tratamento com o laser de Er,Cr:YSGG apresentou os menores valores de RAD (1,43±1,21MPa). Pôde-se concluir que os tratamentos de superfície com todos os lasers testados nos parâmetros de irradiação após a sinterização, provocaram danos à cerâmica Y-TZP. Os tratamentos com os lasers de Nd:YAG e Er,Cr:YSGG antes da sinterização, apesar de apresentarem características micromorfológicas sugestivas de aumento da área de superfície, não foram suficientes para aumentar a resistência adesiva entre a Y-TZP e os cimentos resinosos testados. / The aim of this study was to evaluate the effects of Nd:YAG, CO2 and Er,Cr:YSGG lasers on the surface treatment of Y-TZP ceramic before and after the final sintering by means of Scanning Electron Microscope (SEM), surface roughness measurement (Ra) and microshear bond strength adhesive resistance test (RAD). In order to do so, Y-TZP bars were produced and distributed among the three experimental phases, being the two first ones selective in what regards identifying parameters for the lasers used in phase 3 of the RAD analysis. In phase 1 SEM parameters varying from 50 to 100 mJ were tested for the Nd:YAG laser, from 2 to 4W for the CO2 laser and from 1 to 3,5W for the Er,Cr:YSGG laser, either before or after the Y-TZP sintering. It was observed that most treatments were able to promote changes in the ceramic with varied intensity according to the parameter used. In phase 2 Ra only treatments with Nd:YAG and Er,Cr:YSGG lasers applied before ceramic sintering were selected, and each laser was individually evaluated and compared to the surface treatment with Rocatec system. The treatments which had the highest Ra values were: 1,6W-20Hz (11.623±3,419) for the Nd:YAG laser and 3W (6,051±1,991) for Er,Cr:YSGG. Rocatec system showed the lowest roughness levels (1,297±0,026). As for phase 3 of the study RAD the highest Ra parameters for each laser were selected as well as the parameter with favorable characteristics to adherence observed in phase 1 SEM. Therefore, the microshear bond strength test was done not only in the Y-TZP ceramic treated with lasers before the final sintering (using 1,6W and 1,2W parameters for the Nd:YAG laser and 3W for Er,Cr:YSGG), but also in the Rocatec system, making use of two double activation resin cements (Panavia e RelyX U100). The ANOVA Split-Plot statistical analysis of the RAD data showed that there were no statistical variations concerning the studied cements. However, in what regards the surface treatments, it was observed that the highest RAD values were obtained for the Rocatec system (20,92±3,4MPa). Both parameters used for the Nd:YAG laser were similar, presenting intermediate RAD values (1,2W=9,79±4 and 1,6W=11,35±3,64 MPa). The treatment which used Er,Cr:YSGG laser presented the lowest RAD values (1,43±1,21MPa). It was possible to conclude that surface treatments with all tested lasers in the irradiation parameters after sintering caused damage to the Y-TZP ceramic. Treatments making use of Nd:YAG and Er,Cr:YSGG lasers before the sintering were not enough in order to increase the adhesive resistance between Y-TZP and the resin cements tested, even though they presented micromorphological characteristics that indicated growth in the surface area.
27

Avaliação da taxa de sobrevida de implantes unitários instalados em maxila com diferentes tratamentos de superfície: estudo retrospectivo / Survival rate of implants with different surface treatments placed in maxilla for single tooth replacement: retrospective study

Rotundo, Ligia Drovandi Braga 09 June 2016 (has links)
O objetivo desse estudo foi avaliar as taxas de sobrevida de implantes unitários, instalados na maxila, com diferentes tratamentos de superfícies: oxidação anódica (AO), duplo ataque ácido (DAE), ataque ácido e jateamento (SAE) e ataque ácido e jateamento modificada (SAE modificada). Também avaliou a influência de outras variáveis sobre estas taxas. Foram avaliados pacientes com implantes unitários em maxila, atendidos no Centro Odontológico da Polícia Militar de São Paulo e do Centro de Excelência em Prótese e Implantes da Universidade de São Paulo (Brasil), entre janeiro de 2008 e julho de 2013. Os seguintes dados foram coletados: sexo do paciente, características do implante (forma, diâmetro, comprimento), tratamento de superfície, localização do implante (maxila anterior ou posterior), presença de enxerto ósseo e falhas de implantes. O desfecho primário foi a perda do implante (falha). Estatísticas descritivas foram realizadas para caracterizar a distribuição de frequência de implantes em relação às variáveis. A análise da falha do implante foi feita por curvas de sobrevida de Kaplan-Meier. O teste de Mantel-Cox identificou as variáveis associadas à falha do implante ao longo do tempo. A amostra analisada foi constituída por 1076 implantes em 549 pacientes. As falhas ocorreram em 20 implantes (1,9%), 15 deles (75%) em homens e 5 em mulheres (25%). A frequência de falha foi maior em regiões de enxerto ósseo, e esta diferença ocorreu nos implantes em homens e com superfície DAE. A presença de enxerto aumentou em seis vezes as chances de falha do implante em relação às áreas de osso natural. Nos pacientes com implantes com superfície DAE estimou-se que essa chance de falha do implante em área de enxerto aumentou em nove vezes. / The purpose was evaluate the survival rates of single implants installed in maxilla with different surface treatments: anodic oxidation (AO), dual acid-etching (DAE), sandblasted and acid-etched (SAE) e sandblasted and acid-etched modified (SAE modified). It also evaluated the influence of other variables on these rates. Patients with installed single implants in the maxilla treated at Dental Center of Military Police of São Paulo and the Center for Excellence in Prosthodontics and Implants of the University of São Paulo (Brazil) between January 2008 and July 2013 were evaluated. The following data were collected: patient gender, implant characteristics (shape, diameter, length), surface treatment, location of the implant (anterior or posterior maxilla), presence of bone graft and implant failures. The primary outcome was the loss of the implant (failure). Descriptive statistics were used to characterize the frequency distribution of implants in relation to the variables. The analysis of implant failure was made by survival curves of Kaplan-Meier. The Mantel-Cox test was performed to identify variables associated with implant failure over time. The sample consisted of 1076 implants in 549 patients. Failures occurred in 20 implants (1.9%), while 15 of them (75%) were men and 5 women (25%). The frequency of failure was higher in regions of bone graft, and this difference was related to implants in men and in DAE implants. The presence of graft area increased by 6 times the chances of implant failure in relation to areas of natural bone. In DAE implants was estimated that the chance of failure of the implant graft area increased by 9 times.
28

Comportamento mecânico, resistência de união e longevidade de pilares e coroas de zircônia obtidas por sistema CAD-CAM: influência de diferentes tratamentos de superfície / Mechanical behavior, bond strength and reliability of YTZP abutments and crowns processed by CAD/CAM: The role of surface treatments

Dantas, Talita Souza 29 April 2015 (has links)
O objetivo do estudo foi avaliar a resistência de união à zircônia após diferentes tratamentos de superfície e o comportamento mecânico de pilares e coroas de zircônia associados aos mesmos tratamentos. Na primeira fase, 95 discos em zircônia foram obtidos e divididos em cinco grupos (n = 19): GC (grupo controle, sem nenhum tipo de tratamento); GAL (jateamento com partículas de Al2O3 antes da sinterização); GALS (jateamento com partículas de Al2O3 após sinterização); GRO (silanização com sistema Rocatec antes da sinterização) e GROS (silanização com sistema Rocatec após sinterização). Três amostras de cada grupo tiveram a superfície analisada em MEV e MCVL. Dez amostras de cada grupo foram submetidas a ensaio de microcisalhamento e as seis restantes foram submetidas à análise de interface por meio de MEV. A análise estatística utilizou modelo de regressão linear com efeitos mistos e teste de Tukey (p < 0,01). Na segunda fase, 70 pilares do tipo hexágono externo foram obtidos em zircônia e associados a coroas totais com copings de zircônia. Os conjuntos análogo-pilar-coroa também foram divididos em cinco grupos (n=14) e submetidos aos mesmos tratamentos previamente descritos. Ainda, foram realizadas mensurações para verificação da adaptação dos copings sobre os pilares e rugosidade superficial dos discos, copings e pilares em MCVL. Foi realizado ensaio de fadiga mecânica dos conjuntos com carga progressiva de 80, 120, 160, 200, 240, 280 e 320 N, frequência de 5 Hz, totalizando 20.000 ciclos em cada estágio. A ciclagem térmica foi realizada com temperaturas entre 5º C e 55º C. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (probabilidade de sobrevida, teste de Log-Rang, p < 0,05) Os resultados apontaram que o grupo ROS apresentou valores de resistência de união significativamente superiores (p < 0,01) e que a rugosidade superficial foi semelhante para discos e copings (p = 0,22) e para discos e pilares (p = 0,96), e diferente entre copings e pilares (p < 0,01). A desadaptação marginal foi maior para o grupo RO (p < 0,01) e a probabilidade de sobrevida dos conjuntos foi similar para todos os grupos testados (p = 0,57). Concluiu-se que a utilização do Rocatec aumenta os valores de resistência de união à zircônia, não compromete o comportamento mecânico do material e sua utilização é viável em peças já sinterizadas. / The aim of this study was to evaluate the bond strength to zirconia after different surface treatments and to evaluate the mechanical behavior of zirconia abutments and crowns associated with these treatments. In the first phase, 95 discs in zirconia were obtained and divided into five groups (n = 19): GC (control group, without any treatment), GAL (air particle abrasion with Al2O3 particles before sintering), GALS (air particle abrasion with Al2O3 particles after sintering), GRO (silanization with Rocatec system before sintering) and GROS (silanization with Rocatec system after sintering). Three samples of each group had the surfaces analyzed in SEM and CLSM. Ten samples of each group were subjected to microshear test and the other remaining six had their interface examined by SEM. The statistical analysis used a linear regression model with mixed effects and Tukey test (p <0.01). In the second stage, 70 external hex abutments were obtained in zirconia and associated with crowns and zirconia copings. The analog-abutment-crown assemblies were also divided into five groups (n = 14) and subjected to the same treatments described previously. Measurements to verify the adaptation of copings on the abutments and surface roughness of the discs, copings and abutments were performed in CLSM. A fatigue test was carried with progressive load of 80, 120, 160, 200, 240, 280 and 320 N, frequency of 5 Hz and 20,000 cycles at each stage. Thermal cycling was performed with temperatures between 5° C and 55° C. After mechanical tests, the results were subjected to statistical analysis (survival probability, Log-Rang test, p <0.05) The results showed that the ROS group had significantly higher bond strength values (p < 0.01) and that the surface roughness was similar for discs and copings (p = 0.22) and for discs and abutments (p = 0.96), and was different between copings and abutments (p < 0.01). The marginal gap was higher for RO group (p < 0.01) and the survival probability of the sets was similar for all tested groups (p = 0.57). It was concluded that the use of Rocatec increases the bond strength values to zirconia, does not compromise the mechanical behavior of the material and its use is now feasible in sintered parts.
29

Avaliação da influência de diferentes tratamentos de superfície na resistência de união ao cisalhamento entre zircônia Y-TZP e o cimento resinoso / Influence of different surface treatments on shear bond strength between zirconia Y-TZP and resin cement

Maeda, Fernando Akio 12 September 2012 (has links)
OBJETIVOS:1a etapa: validar teste de cisalhamento utilizando um novo dispositivo de padronização através da comparação dos valores de resistência de união (RU) entre a zircônia com dois tratamentos de superfície e um cimento resinoso, aos resultados obtidos com testes de cisalhamento convencional e microcisalhamento; 2a etapa: avaliar o efeito dos primers metálicos à base de MDP por meio da RU entre zircônia Y-TZP e diferentes tipos de cimentos resinosos (de ativação química, duais e auto-adesivo); 3a etapa: avaliar o efeito de dois lasers Nd:YAG e Er:YAG e do jateamento com óxido de alumínio (JAT) na superfície da zircônia Y-TZP antes da sua sinterização final e da abrasão triboquímica mais silano (controle positivo) após a sinterização final, por meio da resistência à flexão (RF), rugosidade superficial (RS) e RU; 4a etapa: avaliar a estabilidade da união entre a zircônia e um cimento resinoso com um primer à base de MDP e de um laser de alta potência após a termociclagem. Os tratamentos superficiais utilizados nesta etapa foram escolhidos com base nos resultados da 2a e 3a etapas. MATERIAL E MÉTODOS: para os testes de RU foram confeccionados corpos de prova de Y-TZP com dimensões 6x6x3mm, e para o teste de RF 2,5x4,5x20 mm. Para 1a etapa os tratamentos de superfície foram JAT+Signum Ziconia Bond (SZB Heraeus), abrasão triboquímica foi realizada Rocatec (ROC 3M Espe), o silano utilizado foi RelyX Ceramic Primer (3M Espe) e os cimentos resinosos: Panavia F (Kuraray), NX3 (Kerr), seT (SDI), Multilink (Ivoclair). Durante a 3a etapa a abrasão triboquímica foi realizada ROC, o laser Nd:YAG (Power Laser ST6, Lares Research - 1,2W, 10 Hz) e Er:YAG (Kavo Key II, KaVo Co. - 120 mJ, 6 Hz). O teste de cisalhamento com dispositivo de padronização foi o método de avaliação da RU utilizado para as 2a, 3a e 4a etapas. Os dados dos testes de RU, RG foram analisados pela ANOVA e Tukey (=0,05) e RF por Kruskall-Wallis (=0,05). RESULTADOS: 1a etapa: pelo teste de microcisalhamento os materiais se comportaram da seguinte forma: JAT+SZB>ROC>CO, sendo que para os outros dois testes de cisalhamento o seguinte ranqueamente foi obtido: JAT+SZB=ROC>CO. 2a etapa: o SZB apresentou maiores valores de RU para todos os cimentos quando comparados aos grupos controle. O ZP aumento os valores para o cimento Panavia F e NX3. Já o AP aumentou os valores para o cimento seT. 3a etapa: para o teste de RU o JAT e Er:YAG resultaram em valores similares ao ROC, sendo que Nd:YAG resultou em maiores valores comparado ao ROC. Quando avaliados por RS: Nd:YAG>Er:YAG>JAT>ROC; já para RF: ROC>JAT=Nd:YAG= Er:YAG. 4a etapa: Após o teste de cisalhamento os seguinte ranqueamento foi obtido: Nd:YAG 24h>Nd:YAG termociclado=SZB 24h>SZB termociclado. CONCLUSÕES: Uma vez que o teste de cisalhamento com dispositivo de padronização mostrou resultados similares ao teste de cisalhamento convencional pode ser um método viável para avaliação da RU. O tratamento com Nd:YAG antes da sinterização final se mostrou efetivo nos valores de RU. / OBJECTIVES: first stage: validate shear test using a new device for standardized by comparing the values of bond strength (BS) with conventional shear test and microshear test, between zirconia and a resin cement with two surface treatments. Second stage: evaluate the effect of metal primers based on MDP by BS between YTZP and different types of resin cements. Third stage: evaluate Y-TZP surface treatments effect of two lasers (Nd:YAG and Er:YAG) and two sandblasting procedures, with Al2O3 (JAT) before final sintering and tribochemical slicatization after the final sintering, through the flexural resistance (FR) surface roughness (SR) and BS. Fourth stage: evaluate the bonding stability between zirconia and resin cement using a MDP-based primer or a high power laser, after thermal cycling. MATERIAL AND METHODS: BS Y-TZP specimens were prepared with dimensions of 6x6x3mm, and for FS test with 2,5x4,5x20 mm. In the first stage the surface treatments of the specimens were JAT+ Signum Ziconia Bond (SZB - Heraeus), tibochemical silicatization using Rocatec (ROC - 3MEspe) and control (CO - without treatment). In the second stage the primers used were Alloy-Primer (AP - Kuraray), SZB, Z-Prime Plus (ZP - Bisco), and the resin cements: Panavia F (Kuraray), NX3 (Kerr), set (SDI), Multilink (Ivoclair). During the third stage the tribochemical silicatization was perfomed using ROC. The shear bond strength device standardized was used to evaluate the BS of second, third and fourth stage. Test data for BS, SR were analyzed by ANOVA and Tukey test ( = 0.05) and FS by Kruskall-Wallis test ( = 0.05). RESULTS: first Stage: the microshear test groups behave as follow: JAT+SZB> ROC>CO, and for the other two shear tests following the ranking were obtained: JAT+SZB=ROC>CO. Second stage: the SZB showed higher BS for all cements when compared to control groups. The ZP values increased for Panavia F and NX3. AP values increased only for the seT cement. Third stage: BS values for JAT and Er:YAG were similar to ROC, and Nd:YAG was higher compared to the ROC. When evaluated by SR: Nd:YAG> Er:YAG>JAT> ROC, while for FS: ROC> JAT = Nd:YAG = Er:YAG. Fourth stage: after the shear test the following ranking was obtained: Nd:YAG 24h> Nd:YAG thermocycled = SZB 24h> SZB thermocycled. CONCLUSIONS: shear bond strength test with standardized device showed similar result to the conventional shear bond strength, and it can be considered a viable method for evaluating the BS. Treatment with Nd:YAG before the final sintering was effective in BS.
30

Investigação do efeito de moléculas auto-organizáveis na resistência à corrosão da liga de Alumínio 1050 / Investigation on the of effect of self assembling molecules on the corrosion resistance of the 1050 aluminium alloy

Szurkalo, Margarida 16 December 2009 (has links)
Tratamentos de superfície são técnicas amplamente utilizadas com a finalidade de aumentar a resistência à corrosão de materiais metálicos. No caso específico do alumínio e ligas de alumínio, o tratamento com cromo hexavalente é um dos processos mais utilizados. Isso, em razão da eficiência e da facilidade de aplicação desse processo. Entretanto, em virtude de restrições ambientais e do elevado custo de tratamento de resíduos gerados neste processo, métodos alternativos para sua substituição vêm sendo avaliados. Neste contexto, o presente estudo investigou o processo de formação e proteção à corrosão fornecida por filmes de moléculas autoorganizáveis de compostos à base de fosfonatos sobre a liga de alumínio 1050. Para definir as condições do tratamento foram utilizadas medidas de condutividade e de ângulo de contato, juntamente com ensaios eletroquímicos. Técnicas eletroquímicas, especificamente: medidas de variação do potencial a circuito aberto (PCA), espectroscopia de impedância eletroquímica (EIE) e polarização potenciodinâmica foram utilizadas para avaliar a proteção à corrosão. Os diagramas experimentais de impedância foram interpretados utilizando circuitos elétricos equivalentes que simulam modelos do filme de óxido que se forma na superfície da liga. Os resultados fornecidos com a liga tratada com moléculas auto-organizáveis foram comparados com resultados obtidos em iguais condições com amostras da liga sem qualquer tratamento ou cromatizada com Cr(VI) e mostraram que o tratamento com moléculas auto-organizáveis aumenta significativamente a resistência à corrosão da liga e apresenta, em determinadas condições, desempenho próximo ao fornecido pelo processo de cromatização. / Surface treatments are widely used to increase the corrosion resistance of metallic materials. Specifically for aluminum and aluminum alloys, treatment with hexavalent chromium is one of the most used, due to its efficiency and ease of application. However, because of environmental restrictions and the high cost involved in the treatments of waste generated in this process, alternative methods for its replacement are necessary. In this context, this study investigated the effect of the surface treatment with self-assembling molecules (SAM) based on phosphonate compounds on the corrosion of the 1050 aluminum alloy. The conditions adopted for the SAM treatment were determined by conductivity and contact angle measurements, besides electrochemical experiments. Electrochemical techniques, specifically: measurement of the open circuit potential (OCP) variation with time, electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization curves were used to evaluate the corrosion resistance of the 1050 aluminum alloy exposed to SAM treatment The experimental impedance diagrams were interpreted using equivalent electrical circuit models that simulate film that is formed on the alloy surface. The results of the samples treated with SAM were compared with those of samples either without any treatment or treated with chromatizing conversion coating with Cr(VI) and showed that the first treatment significantly increased the corrosion resistance of the aluminum alloy and approached that of chromatizing with Cr(VI) process.

Page generated in 0.0789 seconds