• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 162
  • 98
  • 23
  • 18
  • 17
  • 10
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 385
  • 77
  • 57
  • 37
  • 36
  • 36
  • 35
  • 35
  • 31
  • 28
  • 28
  • 27
  • 26
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Influência dos parâmetros de soldagem na resistência à fluência de juntas soldadas de aço  ASTM A 335 P91. / Influence of welding parameters on creep resistance of ASTM A 335 P91 steel welded joint.

Garcia, Diego Martins 03 May 2013 (has links)
A utilização do aço ASTM A 335 P91 tem sofrido um aumento considerável, especialmente em função da necessidade de materiais com maior resistência à fluência para aplicações em unidades de utilidades (geração de vapor) e de processo. Por ser um material de difícil soldabilidade, diversos problemas são enfrentados durante a construção das unidades e, posteriormente, durante manutenção, geralmente em função de problemas de soldagem oriundos da fase de fabricação e construção. As normas de projeto e construção utilizadas internacionalmente vêm sofrendo adaptações a fim de melhorar a utilização deste material, mas seus requisitos ainda apresentam importantes lacunas em relação às principais práticas recomendadas pela literatura técnica mais atual. Visando uma melhor utilização deste material, obtendo juntas soldadas com propriedades mecânicas e metalúrgicas mais consistentes, o presente trabalho foi desenvolvido avaliando-se a influência de parâmetros de soldagem energia de soldagem e temperatura de tratamento térmico pós-soldagem (TTPS) sobre as propriedades mecânicas e metalúrgicas, incluindo resistência à fluência, de juntas soldadas de aço ASTM A 335 P91. Foram testadas nove juntas soldadas, combinando três níveis de energia de soldagem com três temperaturas de TTPS. Os resultados obtidos indicam que é possível ter melhor controle sobre as propriedades deste material, desde que se opere com níveis mais restritos de energia de soldagem e maiores temperatura de TTPS, observando-se as limitações pertinentes, especialmente no que tange à temperatura crítica de transformação Ac1. / The use of ASTM A 335 P91 has been increased considerably specially because of the need for materials with higher creep resistance for power generation (nuclear and thermoelectric) and oil and gas processing applications. As this is a material with poor weldability, several issues are faced during construction of these unities, and later during maintenance usually associated with welding problems originated in the fabrication and construction phase. The design and construction codes most used worldwide are receiving important revisions targeting to enhance the use condition of this material but its requirements still show important lacks when compared to the main practices recommended by the more recent technical literature. Aiming a better usage of this material obtaining sound welded joints with more consistent metallurgical and mechanical properties, this work was developed assessing the influence of some welding parameters welding heat input and temperature of post-­weld heat treatment (PWHT) on the metallurgical and mechanical properties, including creep strength, of welded joints of ASTM A 335 P91 steel. Nine welded joints were submitted to testing, combining three different levels of welding heat input with three different PWHT temperatures. The results show that it is possible to have a better control over the properties of this material since it is used lower welding heat inputs combined to higher PWHT temperatures, taking care about the limitations regarding the critical transformation temperature Ac1.
122

Initiation and propagation of corrosion in dry-cast reinforced concrete pipes

Unknown Date (has links)
This study investigates corrosion initiation and propagation in instrumented specimens obtained from segments of dry-cast reinforced concrete pipes. Potential, LPR and EIS measurements were carried out. During the propagation stage in different exposures, reinforcement eventually reached negative potentials values, which suggest mass transfer limitations. So far these specimens show no visual signs of corrosion such as cracks or corrosion products with one exception; where corrosion products have reached the surface. Moreover, the apparent corrosion rate values obtained suggest high corrosion rate. No crack appearance so far, could be explained by the high porosity of the specimens; the corrosion products are filling these pores. It is speculated that although, there might be mass transfer limitations present, the current demanded by the anode is being balanced by a larger cathode area due to macrocell effects, since the high moisture conditions likely reduced the concrete resistivity and increased the throwing power. / by Hariharan Balasubramanian. / Thesis (M.S.C.S.)--Florida Atlantic University, 2013. / Includes bibliography. / Mode of access: World Wide Web. / System requirements: Adobe Reader.
123

Accelerated corrosion of steel in dry-cast reinforced concrete pipes after initiation

Unknown Date (has links)
Instrumented dry-cast reinforced concrete pipe (DC-RCP) specimens in which corrosion of the reinforcing steel had initiated were selected to accelerate the corrosion. Type C and type F DC-RCP were used. An anodic current density of various magnitudes (0.5 μA/cm2, 1 μA/cm2 and 2.5 μA/cm2) was applied during the corrosion propagation stage. The specimens were placed in high humidity and selected specimens were later covered with wet sand. Selected specimens were terminated for visual examination and gravimetric analysis. Typically, the reinforcement potentials during the accelerated corrosion period were more negative for F specimens compared to C specimens. The C specimens experienced ~2× more corrosion than the F specimens. The accumulated corrosion products did not cause cracks. A method was developed that allows for modest corrosion acceleration during the corrosion propagation stage of DC-RCP. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2014. / FAU Electronic Theses and Dissertations Collection
124

Initiation and propagation of corrosion in dry-cast reinforced concrete ring specimens

Unknown Date (has links)
The corrosion propagation stage of D-CRP (types F and C) was tested under immersion in water, high humidity, and covered with wet sand. The half-cell potential, linear polarization test, and electrochemical impedance spectroscopy measurements were performed. Selected specimens were terminated after 300 days of exposure and visually inspected. Based on corrosion potential measurements obtained during the corrosion propagation observation, and calculated corrosion rate based on LPR measurements: all specimens were actively corroding. Additionally, EIS-Rc values were calculated for FS, CS and CH specimens. The Rc_EIS were generally greater than Rc_LPR values. EIS spectra for CI and FI specimens usually included mass transport limitations, as these specimens were immersed. Both type of specimens immersed in water (FI and CI), appeared to have higher corrosion rate based on LPR-Rc. However, upon autopsy it was revealed that a more modest amount of corrosion occurred on the reinforcing steel of FI and CI terminated specimens. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2014. / FAU Electronic Theses and Dissertations Collection
125

Influência das ceras orgânicas nas propriedades de filmes tubulares de PEBD

Euzébio Junior, Silvio Hendez January 2017 (has links)
As poliolefinas, em especial os polietilenos (PE) são materiais poliméricos muito utilizados para a produção de filmes tubulares, sendo um dos materiais mais amplamente empregado na indústria de embalagens flexíveis. Dentre os diversos PE industriais, o polietileno de baixa densidade (PEBD) apresenta propriedades reológicas únicas em comparação aos PE lineares e os de alta densidade. A alta viscosidade e as numerosas ramificações longas encontradas neste polímero influenciam na redução da produtividade quando processados. Aditivos das mais variadas composições são adicionados ao polietileno durante o processo de extrusão tubular a fim de melhorar suas propriedades. Um dos aditivos mais empregados para facilitar o fluxo do fundido para processamento de filmes são as ceras sintéticas, sendo a mais usada a de polietileno oxidado (CP). Na procura de alternativas de cera de fonte orgânica e/ou de fonte natural, o objetivo deste trabalho é avaliar a influência do tipo e teor de cera na processabilidade e propriedades finais de filmes tubulares de PEBD. Foram usados 3 tipos de ceras: CP (cera de polietileno), a carnaúba (CC) e o monoestearato de glicerol (CM), sendo processadas 4 formulações de PEBD/cera nas proporções mássicas de 99,5/0,5; 99/1; 98/2 e 96/4 m/m com os três tipos de cera e comparados com o PEBD sem cera. Os filmes foram caracterizados através de ensaios físicos, ópticos, químicos, térmicos, reológicos e mecânicos. Propriedades ópticas como o brilho e opacidade foram alteradas pela adição das ceras pois um aumento na concentração das ceras aumenta o grau de cristalinidade dos filmes. A cera de carnaúba apresentou amarelamento nos filmes produzidos com maiores concentrações. Resultados deste estudo mostraram que o uso da cera sintética, CP e da natural de carnaúba, aumentam a produtividade do filme tubular de PEBD, sendo o teor ótimo de 1% de cera, sem ter influência significativa na espessura e largura do filme tubular. O uso de agentes de fluxo alternativos de natureza orgânica é viável pois obtiveram resultados similares e superiores ao padrão nos filmes testados. / Polyolefins, especially polyethylenes (PE) are widely used polymeric materials for the production of tubular films, being one of the most widely used materials in the flexible packaging industry. Among the various industrial PE, low density polyethylene (LDPE) has unique rheological properties compared to linear and high density PE. The high viscosity and the numerous long branches found in this polymer influence the reduction of productivity when processed. Additives of the most varied compositions are added to the polyethylene during the tubular extrusion process in order to improve their properties. One of the most used additives to facilitate the flux of melt for film processing is synthetic waxes, the most used being oxidized polyethylene (CP). In the search for organic and / or natural source wax alternatives, the objective of this work is to evaluate the influence of the type and content of wax on the processability and final properties of tubular films of LDPE. Three types of waxes were used: CP (polyethylene wax), carnauba (CC) and glycerol monostearate (CM), and 4 formulations of LDPE / wax were processed in mass proportions of 99.5 / 0.5; 99/1; 98/2 and 96/4 m / m with the three types of wax and compared with LDPE without wax. The films were characterized by physical, optical, chemical, thermal, rheological and mechanical tests. Optical properties such as brightness and opacity are altered by the addition of waxes as an increase in the concentration of the waxes increases the degree of crystallinity of the films. Carnauba wax shows a yellowing in the films produced with higher concentrations. Results of this study showed that the use of synthetic wax, CP and natural carnauba, increase the productivity of the tubular film of LDPE, being the optimal content of 1% of wax, without having a significant influence on the thickness and width of the tubular film. The use of alternative flow agents of organic nature is feasible because they obtained similar and superior results to the standard in the films tested.
126

Análise teórica e experimental de ligações em aço entre pilar tubular de seção circular e viga de seção I / Theoretical and experimental analysis of steel connections between circular hollow section column and I section beam

Masioli, Calil Zumerle 15 April 2011 (has links)
O atrativo estético proporcionado pela forma arredondada é o fator que na maioria das vezes determina a utilização de estruturas tubulares circulares. É crescente a concepção de pórticos formados por colunas tubulares e as tradicionais vigas de seção I. Esse tipo de ligação ainda é pouco estudado no Brasil, e esse trabalho busca avançar no entendimento do comportamento estrutural dessas ligações. Foram realizados estudos analíticos, numéricos e experimentais em quatro configurações de ligação, com diafragmas externos transversais, chapa de alma, soldas, parafusos e enrijecedor. Avaliou-se a relação M-\'fi\' (momento-rotação) das ligações estudadas e os parâmetros envolvidos como resistência, rigidez e ductilidade, evidenciando-se o modo de colapso das ligações. O estudo analítico foi desenvolvido baseado nas recomendações do Eurocode 3 (2005), com a utilização do Método das Componentes. A análise numérica, através do Método dos Elementos Finitos, foi realizada por meio dos programas computacionais TRUEGRID® e ANSYS®. Os modelos numéricos consideram as características mecânicas do aço, como plastificação, encruamento e não-linearidades geométricas e de contato. As formulações do Eurocode 3 (2005), adaptadas para a determinação da resistência das ligações viga-coluna, apresentaram resultados coerentes e a análise numérica foi representativa frente aos resultados experimentais. A utilização de diafragmas externos conectados à viga apresentou boa funcionalidade, ajudando na distribuição das tensões na região da ligação, melhorando o comportamento da coluna. / The aesthetic appeal provided by the round shape is the factor that mostly determines the use of circular tubular structures. There is an increasing conception of structures formed by hollow columns and traditional beams of section I. This type of connection hasn\' t been sufficiently studied in Brazil, and this paper tries to advance the comprehension of the structural behavior of these connections. Analytical, numerical, and experimental study were performed in four connections configurations, with transverse external diaphragms, web plate, welds, bolts and stiffener. The relation M-\'fi\' (moment-rotation) of the studied connections and the parameters involved such as strength, stiffness and ductility were evaluated, evidencing the failure mode of connections. The analytical study was developed based on recommendations of Eurocode 3 (2005) using the Method of Components. The numerical analysis using the Finite Element Method was performed with the computer programs TRUEGRID® and ANSYS®. The numerical models consider the mechanical characteristics of steel, such as yielding and hardening, and also the geometric and contact nonlinearity. The formulations of Eurocode 3 (2005), adapted for determining the strength of beam-column connections, showed coherent results and the numerical analysis was representative compared to experimental results. The use of external diaphragm connected to the beam showed good functionality, helping in the distribution of stress in the region of connection, improving the behavior of the column.
127

Efeitos da anexina1 na isquemia e reperfusão renal: estudo funcional e histopatológico em modelo experimental

Facio Júnior, Fernando Nestor 14 March 2006 (has links)
Made available in DSpace on 2016-01-26T12:51:24Z (GMT). No. of bitstreams: 1 fernandonestor_tese.pdf: 1042593 bytes, checksum: af0a555c2adb2f553fd7214a6ca2774b (MD5) Previous issue date: 2006-03-14 / The aim of the present study was to investigate the effects of the use of the anti-inflammatory protein annexin 1 (Anx-A1), which is found in most cells. It is characterized by its ability in binding to calcium and phospholipids, conferring protection against the initial effects of ischemia-reperfusion injury. Right nephrectomy was performed on 48 adult males Wistar rat, with sizes ranging between 250-300 g, maintained on a diet normosodic , normoprotein and with water ad libitum. The animals was divided into 3 groups: Annexin-1/Ischemia (Anx-A1-I/R) (n=16), vehicle (PBS40)-Ischemia (Vehicle-I/R) (n=16) and Sham Group (n=16). The endovenous administration of Anx-A1 was made 30 minutes before ischemia of the left renal artery. The animals of each group were divided and studied at 2 and 7 days post-reperfusion, in respect to the glomerular, tubular and renal structure functions. The results showed that there was a reduction in the glomerular filtration rate (GFR) in the Vehicle-I/R Groups at 2 and 7 days post-reperfusion (0.42 ± 0.02 mL/min-100g and 0.48 ± 0.05 mL/min-100g, respectively). There was a significantly greater filtration rate in the Anx-A1-I/R Groups compared to the Vehicle-I/R Groups (0.86 ± 0.05 mL/min-100g and 0.73 ± 0.04 mL/min-100g, respectively). A significant difference between the Anx-A1-I/R and Sham Groups (p-value < 0.01) was also observed (7days). The fractional sodium excretion (FeNa) was significantly higher in the Vehicle-I/R Groups when compared to the Anx-A1-I/R and Sham Groups on the 2nd and 7th post-perfusion days. On the 2nd day of the study, the fractional sodium excretion was 0.17 ± 0.01% for the Anx-A1-I/R, 0.42 ± 0.03% for the Vehicle-I/R and 0.21 ± 0.01% for the Sham groups (p-value < 0.001). On the 7th day, the values were 0.27 ± 0.03%, 0.52 ± 0.03% and 0.29 ± 0.01%, respectively (p-value < 0.001). The potassium excretion fraction (FeK) on the 2nd and 7th post-perfusion days did not differentiate between the Anx-A1-I/R and Sham Groups, but it was significantly higher in the Vehicle-I/R Groups. The urinary-plasmatic osmolality ratio (U/Posm) showed a significant reduction in the Vehicle-I/R Groups after 2 and 7 days when compared with the Anx-A1-I/R and Sham Groups. A histopathologic evaluation of renal cortex samples, taken on the 2nd and 7th post-perfusion days, revealed a significant increase in the intravascular and transmigrated neutrophils in ischemic areas of the Vehicle-I/R Groups. Additionally, high rates of transmigrated neutrophils were identified in the ischemia-reperfusion areas of samples of renal medulla from the Vehicle-I/R Group taken on the 2nd and 7th days. There was a significant reduction of the neutrophil transmigration in samples of renal medulla on the 2nd and 7th post-perfusion days in the Anx-A1-I/R Groups, as well as a lower intravascular neutrophil rate. On the 2nd and 7th post-perfusion days, the Sham Group presented with structures of distal and proximal convoluted tubules and well-preserved brush-border structures in the renal cortex and medulla samples as seen by light microscopy. Similar results were evidenced in the Anx-A1-I/R Groups with preserved structures in the tubules, basal membrane and glomeruli. In the Vehicle-IR Groups, numerous monocytes, cellular debris inside proximal convoluted tubules, dilated capillaries and alterations in the basal membrane structure were seen. These results suggest that the administration of annexin-1 thirty minutes before renal ischemia in rat , prevents the transmigration of neutrophils and confers protection against the initial effects of ischemia-reperfusion injury, as well as providing protection to the glomerular, tubular and renal structure functions. / O presente estudo objetivou investigar os efeitos do uso da anexina 1 (Anx-A1), considerada proteína antiinflamatória e que está presente na maioria das células. Caracteriza-se pela sua habilidade em ligar-se ao cálcio e fosfolipídeos, conferindo proteção contra os efeitos iniciais da lesão por isquemia e reperfusão. Realizou-se nefrectomia à direita em 48 ratos (Wistar-adultos-machos), pesando entre 250-300 gramas, mantidos com dieta normosódica , normoprotéica e água ad libitum. Os animais foram divididos em 3 grupos: Anexina 1-Isquemia (Anx-A1-I/R) (n=16), Veículo(PBS-40)-Isquemia (Veic-I/R) (n=16) e grupo Sham (n=16). A administração de anexina1 endovenosa foi realizada 30 minutos antes do clampeamento da artéria renal esquerda. Após reperfusão, os animais de cada grupo foram divididos e estudados com 2 e 7 dias, quanto às funções glomerulares , tubulares e à estrutura renal. Os resultados mostraram que houve redução da taxa de filtração glomerular (RFG) nos grupos veículo-I/R com 2 e 7 dias de experimento (0,42 ± 0,02 ml-min-100g e 0,48 ± 0,05 ml-min-100g, respectivamente) e verificamos aumento significativo da taxa de filtração glomerular nos grupos Anx-A1-I/R comparados aos grupos veículo-I/R (0,86 ± 0,05ml-min-100g e 0,73 ± 0,04ml-min-100g, respectivamente). Observou-se diferença significativa entre os grupos Anx-A1-I/R e Sham com 7 dias (p<0,01). A excreção fracional de sódio (FeNa) apresentou-se significantemente aumentada nos grupos veículo-I/R, comparada aos grupos Anx-A1-I/R e Sham nos 2º e 7º dias de experimento; apresentando assim no 2º dia de estudo,Anx-A1-I/R (0,17 ± 0,01%), Veic-I/R (0,42 ± 0,03%) e Sham (0,21 ± 0,01%) (p<0,001); e no 7º dia, Anx-A1-I/R (0,27 ± 0,03%), Veic-I/R (0,52 ± 0,03%) e Sham (0,29 ± 0,01%) (p<0,001). A fração de excreção de potássio (FeK) com 2 e 7 dias de experimento não diferiram entre os grupos Anx-A1-I/R e Sham, mas a FeK aumentou significativamente nos grupos Veic-IR. A razão das osmolalidades urinário-plasmáticas (U/Posm) mostraram uma redução importante nos grupos Veic-I/R em experimentos com 2 e 7 dias, comparados aos grupos Anx-A1-I/R e Sham. A avaliação histopatológica revelou aumento significativo de neutrófilos intravasculares e transmigrados, em áreas isquêmicas dos grupos Veic-I/R, de amostras avaliadas da porção do córtex renal com 2 e 7 dias. Verificaram-se altas taxas de transmigração de neutrófilos nas áreas de isquemia-reperfusão nos grupos Veic-I/R com 2 e 7 dias, em amostras avaliadas de medula renal. Houve significativa redução do extravasamento de neutrófilos em análise quantitativa, nas amostras de medula renal com 2 e 7 dias de estudo, nos grupos anexina 1-I/R, bem como menor taxa de neutrófilos no espaço intravascular. À microscopia de luz, verificou-se que, em amostras de córtex e medula renal, com 2 e 7 dias, o grupo Sham apresentou estruturas dos túbulos contorcidos proximais, distais e borda em escova bem preservados. Notou-se resultados semelhantes nos grupos de anexina1-I/R, com estruturas preservadas nos túbulos, membrana basal e glomérulos. Nos grupos Veic-I/R, verificou-se a presença de debris celulares no interior de túbulos contorcidos proximais, capilares dilatados e alterações na estrutura da membrana basal. Estes resultados sugerem que a administração da anexina1, trinta minutos antes da isquemia renal em ratos, previne a transmigração de neutrófilos e confere proteção contra os efeitos iniciais da lesão por isquemia e reperfusão, bem como proteção das funções glomerulares, tubulares e da estrutura renal.
128

Desenvolvimento de tubos solares aplicados em iluminação de interiores a partir de materiais poliméricos metalizados

Spacek, Anderson Diogo January 2017 (has links)
O presente trabalho teve como objetivo desenvolver sistemas tubulares de condução de luz natural propondo a substituição do alumínio revestido com prata (que é o sistema comercializado atualmente por diversas empresas internacionais), por polímero metalizado. Espera-se com isso diversificar os materiais empregados na fabricação destes dispositivos reduzindo significativamente o custo. Os sistemas tubulares de condução de luz natural permitem o aproveitamento da luz solar para iluminação de interiores, contribuindo para a redução do consumo de energia elétrica. No presente estudo foram avaliados como material estrutural os polímeros (PP, PS, PEAD, PEBD, ABS nas condições virgem e reciclada), revestidos com alumínio e cromo e submetidos à metalização por evaporação no vácuo (íon plating) ou por projeção catódica (sputtering). Os materiais poliméricos foram caracterizados quanto sua resistência mecânica através de ensaios de tração (norma ASTM D638). Os revestimentos de alumínio e cromo depositados nos materiais poliméricos, foram caracterizados quanto à adesão (norma ASTM D3359-09) e quanto à reflexividade (norma ASTM E903). Essas propriedades foram avaliadas comparativamente ao material empregado em um sistema tubular de condução de luz natural comercial (referencia). Os resultados obtidos dos ensaios realizados, demonstraram que os melhores sistemas obtidos foram o PP reciclado metalizado com alumínio pelo processo de projeção catódica, e também ABS e PS virgem metalizados com alumínio pelo processo de evaporação no vácuo. Para a validação em escala real, foram elaborados: um protótipo de PP reciclado metalizado com alumínio pelo processo de projeção catódica e um protótipo de ABS virgem metalizado com alumínio pelo processo de evaporação no vácuo. Enquanto, o tubo protótipo de ABS virgem metalizado com alumínio chegou em média diária a atingir 65% do rendimento comparado com o tubo referência, o PP reciclado metalizado com alumínio pelo processo de projeção catódica chegou apenas a 21%. Isso evidenciou a viabilidade técnica de construção de um tubo para condução da luz solar direta para iluminação utilizando ABS virgem metalizado com alumínio com rendimento de 65% do tubo de referência, o qual pode ser comercializado uma redução de custo estimado de 46,5% em relação a referência. / This paper aims to develop tubular daylight systems for transporting natural light by substituting silver coated aluminum (which is the system currently supplied by several international companies), for metalized polymer. This is expected to diversify the materials used in the manufacturing of those tubular devices, significantly reducing their cost. The tubular systems for conducting natural light enable to maximize the use of natural daylight for interior lighting, minimizing the consumption of electric energy. In this study some polymers (virgin and recycled PP, PS, HDPE, LDPE, and ABS) aluminum or chromium coated were evaluated as structural material. The coating were obtained metallization by vacuum evaporation (ion plating) or by cathodic projection (sputtering). The polymeric materials were evaluated for their mechanical resistance through tensile tests (American Society for Testing and Materials - ASTM D638 standard). The aluminum and chromium coatings deposited on polymeric materials were evaluated for their adhesion (ASTM D3359-09) and for their reflectivity (ASTM E903). These properties were measured comparatively to the material commonly used in a commercial tubular daylight conducting system (reference). The tests results showed that the best systems were the recycled PP metalized with aluminum by the cathodic projection process, and also virgin ABS and virgin PS metalized with aluminum by the vacuum evaporation process. For the real-scale validation, a prototype of recycled PP metalized with aluminum by the cathodic projection process and a prototype of virgin ABS metalized with aluminum by the vacuum evaporation process were made. While the prototype made with virgin ABS metalized with aluminum attained an average daily efficiency of 65% compared to the reference tube, the prototype made with recycled PP metalized with aluminum by the cathodic projection process attained only 21%. Thus, these results demonstrate the technical feasibility of producing a tubular direct daylight conducting system using virgin ABS metalized with aluminum with an efficiency of 65% of the reference tube at an estimated cost 46.5% lower than the reference tube.
129

Avaliação da qualidade da água subterrânea de poços tubulares outorgados no município de Campo Grande - MS /

Cardoso, Juarez Marques January 2019 (has links)
Orientador: Jefferson Nascimento de Oliveira / Resumo: A grande proporção da exploração das águas subterrâneas no Brasil e no mundo se deve às inúmeras vantagens como a qualidade da água, os custos de exploração relativamente baixos e o simplificado tratamento da água para consumo. A importância de se estudar estes recursos hídricos se coloca pela necessidade de investigar os processos em que se dá a exploração da água, desde a autorização da captação do recurso, a gerência de potenciais contaminantes, até a sua qualificação como boa ou imprópria para consumo pela população. Deste modo, o presente trabalho avaliou a qualidade de água subterrânea outorgada do município de Campo Grande, Mato Grosso do Sul e utilizou como fonte dos dados o Sistema IMASUL de Registros e Informações Estratégicas do Meio Ambiente – SIRIEMA, on-line, disponível no site do Instituto de Meio Ambiente de Mato Grosso do Sul (IMASUL), pelo qual se realiza todo o procedimento de solicitação e análise de outorga e que autorizou a publicação dos dados dessa pesquisa seguindo os princípios de acesso às informação sobre Recursos Hídricos , conforme instrumento estabelecido pela Lei Federal 9433 de 1997 e Lei Estadual 2406 de 2002, sob o cuidado ético do sigilo dos nomes das pessoas físicas e/ou jurídicas. O trabalho foi realizado com base nas análises físico-química e microbiológicas de poços outorgados, inseridas no SIRIEMA como parte da documentação obrigatória para solicitação de outorga e dados qualitativos de monitoramento de tais fontes de captação. Foram e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The large proportion of groundwater exploitation in Brazil and in the world is linked to numerous advantages such as water quality, relatively inexpensive operating costs and simplified treatment of water for human consumption. The study and investigation of water resources is necessary to know the processes of exploration of water, from the authorization of the capture of the resource, the management of potential contaminants, until the qualification as own or improper for consumption by the population. Thus, the present study evaluated the groundwater quality granted in the municipality of Campo Grande, Mato Grosso do Sul and used the IMASUL System of Registries and Strategic Environmental Information - SIRIEMA, available on the website of the Institute of Environment of Mato Grosso do Sul (IMASUL), where all the procedure of request and analysis of granting takes place and that authorized the publication of the data of this research following the principles of access to information on Water Resources, according to instrument established by Federal Law number 9433 of 1997 - Brazil and State Law number 2406 of 2002 - Mato Grosso do Sul, under the ethical care of the secrecy of individuals and / or legal entities. The work was carried out based on the physical-chemical and microbiological tests of wells granted, inserted in SIRIEMA as part of the mandatory documentation for requesting data and qualitative data of monitoring of such sources of abstraction. We found parameters ... (Complete abstract click electronic access below) / Mestre
130

Design and construction of a high-speed human-powered boat

Mosley, Kim Arthur January 1982 (has links)
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1982. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING / Bibliography: leaf 51. / by Kim Arthur Mosley. / M.S.

Page generated in 0.0506 seconds