• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 6
  • 1
  • Tagged with
  • 33
  • 33
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Experimental investigation of the performance of a fully cooled gas turbine vane with and without mainstream flow and experimental analysis supporting the redesign of a wind tunnel test section

Mosberg, Noah Avram 16 February 2015 (has links)
This study focused on experimentally determining the cooling performance of a fully cooled, scaled-up model of a C3X turbine vane. The primary objective was to determine the differences in overall effectiveness in the presence and absence of a hot mainstream flowing over the vane. Overall effectiveness was measured using a thermally scaled matched Biot number vane with an impingement plate providing the internal cooling. This is the first study focused on investigating the effect of removing the mainstream flow and comparing the contour and laterally-averaged effectiveness data in support of the development of an assembly line thermal testing method. It was found that the proposed method of factory floor testing of turbine component cooling performance did not provide comparable information to traditional overall effectiveness test methods. A second experiment was performed in which the effect of altering the angle of attack of a flow into a passive turbulence generator was investigated. Measurements in the approach flow were taken using a single wire hot-wire anemometer. This study was the first to investigate the effects such a setup would have on fluctuating flow quantitates such as turbulence intensity and integral length scale rather than simply the mean quantities. It was found that both the downstream turbulence intensity and the turbulence integral length scale increase monotonically with approach flow incidence angle at a specified distance downstream of the turbulence generator. / text
32

External Heat Transfer Coefficient Predictions on a Transonic Turbine Nozzle Guide Vane Using Computational Fluid Dynamics

Enico, Daniel January 2021 (has links)
The high turbine inlet temperature of modern gas turbines poses a challenge to the material used in the turbine blading of the primary stages. Mechanical failure mechanisms are more pronounced at these high temperatures, setting the lifetime of the blade. It is therefore crucial to obtain accurate local metal temperature predictions of the turbine blade. Accurately predicting the external heat transfer coefficient (HTC) distribution of the blade is therefore of uttermost importance. At present time, Siemens Energy uses the boundary layer code TEXSTAN for this purpose. The limitations coupled to such codes however make them less applicable for the complex flow physics involved in the hot gas path of turbine blading. The thesis therefore aims at introducing CFD for calculating the external HTC. This includes conducting an extensive literature study to find and validate a suitable methodology. The literature study was centered around RANS modeling, reviewing how the calculation of the HTC has evolved and the performance of some common turbulence and transition models. From the literature study, the SST k − ω model in conjunction with the γ − Reθ transition model, the v2 − f model and the Lag EB k − ε model were chosen for the investigation of a suitable methodology. The validation of the methodology was based on the extensively studied LS89 vane linear cascade of the von Karman Institute. In total 13 test cases of the cascade were chosen to represent a wide range of flow conditions. Both a periodic model and a model of the entire LS89 cascade were tested but there were great uncertainties whether or not the correct flow conditions were achieved with the model of the entire cascade. It was therefore abandoned and a periodic model was used instead. The decay of turbulence intensity is not known in the LS89 cascade. This made the case difficult to model since the turbulence boundary conditions then were incomplete. Two approaches were attempted to handle this deficiency, where one was ultimately found invalid. It was recognized that the Steelant-Dick postulation could be used in order to find a turbulent length scale which when specified at the inlet, lead to fairly good agreement with data of the HTC. The validation showed that the SST γ − Reθ model performs relatively well on the suction side and in transition onset predictions but worse on the pressure side for certain flow conditions. The v2 − f model performed better on the pressure side and on a small portion of the suction side. Literature emphasized the importance of obtaining proper turbulence characteristics around the vane for accurate HTC-predictions. It was found that the results of the validation step could be closely coupled to this statement and that further work is needed regarding this. Further research must also be done on the Steelant-Dick postulation to validate it as a reliable method in prescribing the inlet length scale.
33

Experimental Aerothermal Performance of Turbofan Bypass Flow Heat Exchangers

Villafañe Roca, Laura 07 January 2014 (has links)
The path to future aero-engines with more efficient engine architectures requires advanced thermal management technologies to handle the demand of refrigeration and lubrication. Oil systems, holding a double function as lubricant and coolant circuits, require supplemental cooling sources to the conventional fuel based cooling systems as the current oil thermal capacity becomes saturated with future engine developments. The present research focuses on air/oil coolers, which geometrical characteristics and location are designed to minimize aerodynamic effects while maximizing the thermal exchange. The heat exchangers composed of parallel fins are integrated at the inner wall of the secondary duct of a turbofan. The analysis of the interaction between the three-dimensional high velocity bypass flow and the heat exchangers is essential to evaluate and optimize the aero-thermodynamic performances, and to provide data for engine modeling. The objectives of this research are the development of engine testing methods alternative to flight testing, and the characterization of the aerothermal behavior of different finned heat exchanger configurations. A new blow-down wind tunnel test facility was specifically designed to replicate the engine bypass flow in the region of the splitter. The annular sector type test section consists on a complex 3D geometry, as a result of three dimensional numerical flow simulations. The flow evolves over the splitter duplicated at real scale, guided by helicoidally shaped lateral walls. The development of measurement techniques for the present application involved the design of instrumentation, testing procedures and data reduction methods. Detailed studies were focused on multi-hole and fine wire thermocouple probes. Two types of test campaigns were performed dedicated to: flow measurements along the test section for different test configurations, i.e. in the absence of heat exchangers and in the presence of different heat exchanger geometries, and heat transfer measurements on the heat exchanger. As a result contours of flow velocity, angular distributions, total and static pressures, temperatures and turbulence intensities, at different bypass duct axial positions, as well as wall pressures along the test section, were obtained. The analysis of the flow development along the test section allowed the understanding of the different flow behaviors for each test configuration. Comparison of flow variables at each measurement plane permitted quantifying and contrasting the different flow disturbances. Detailed analyses of the flow downstream of the heat exchangers were assessed to characterize the flow in the fins¿ wake region. The aerodynamic performance of each heat exchanger configuration was evaluated in terms of non dimensional pressure losses. Fins convective heat transfer characteristics were derived from the infrared fin surface temperature measurements through a new methodology based on inverse heat transfer methods coupled with conductive heat flux models. The experimental characterization permitted to evaluate the cooling capacity of the investigated type of heat exchangers for the design operational conditions. Finally, the thermal efficiency of the heat exchanger at different points of the flight envelope during a typical commercial mission was estimated by extrapolating the convective properties of the flow to flight conditions. / Villafañe Roca, L. (2013). Experimental Aerothermal Performance of Turbofan Bypass Flow Heat Exchangers [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/34774 / TESIS

Page generated in 0.1207 seconds