• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

"Ultra-sonografia recurso imaginológico aplicado à odontologia" / Ultrasonography – imaginologic resource applied to dentistry Odontologia.

Thásia Luiz Dias Ferreira 01 April 2005 (has links)
O ultra-som é um recurso imaginológico relativamente recente, que foi desenvolvido primeiramente para utilização submarina, e só depois fundamentada na área da Saúde. Esse sistema utiliza ondas ultra-sônicas, que são produzidas em um dispositivo denominado transdutor, responsável também por enviá-las ao tecido a ser avaliado; é também o responsável por receber os ecos sonoros que são refletidos pelas estruturas que possuem diferentes impedâncias acústicas, obtendo-se assim os resultados. As primeiras gerações de US (modo-A) utilizavam um sistema numérico pouco atrativo para a interpretação dos resultados. Somente com o advento do modo-B, que apresenta imagens tomográficas, o ultra-som começou a se tornar um método imaginológico mais utilizado. Com a evolução dos aparelhos, a técnica permitia que as imagens fossem processadas a uma velocidade suficientemente rápida para deixar passar a percepção de movimento. É possível por meio do Doppler colorido, caracterizado pela associação das imagens em movimento em tempo real, mapear o fluxo vascular. Pela revisão da literatura, concluímos que: o ultra-som é um exame imaginológico recente; é um método auxiliar na elaboração do diagnóstico, não invasivo, indolor e sem nenhum efeito deletério conhecido até os dias atuais; é um exame imaginológico com alta especificidade para tecidos moles; é um recurso capaz de detectar, delimitar 9 (inclusive em profundidade) e avaliar o conteúdo interno, tanto na normalidade quanto nas alterações do complexo dento-maxilo-cervico-facial; a interpretação pode ser feita em tempo real, sendo passível de repetição, sempre que necessário; é operador-dependente e tem ampla aplicação nas diferentes Especialidades Odontológicas. / The Ultrasound (US) is a relatively recent imaginologic resource that was first developed for submarine use, and then applied in the Health area. This system makes use of ultrasonic waves, produced in a device called transducer, which is also responsible for sending them to the tissue to be evaluated. The transducer is responsible for receiving the eco sounds that are reflected by structures that possess different acoustic impedances, thus obtaining results. The first generations of US (A-mode) used a numerical system that was not very attractive for results interpretation. Only with the discovery of the B-mode, which presents tomographic images, the ultrasound started to become a more utilized method. As devices evolved, the technique allowed images to be processed in such a high velocity that would let the perception of movement pass. It is possible to map the vascular flux in real time by using Coloured Doppler, characterized by the association of moving images. By literature review, we concluded that: the ultrasound is a recent imaginologic exam; it is a non-invasive, painless, auxiliary diagnostic method and has shown no known side effects until the present date; it is a high-specificity imaginologic exam for soft tissues; it is a resource capable to detect, delimitate (including in depth), and evaluate the internal content in normality as much as in dento-maxilo-cervico-facial alterations; the interpretation can be made in real time, and repetition is always 11 possible when necessary; it is operator-dependent and has a wide application in different odontological specialities.
82

O efeito do ultra-som terapêutico na vascularização pós lesão muscular experimental em coelhos / The effect therapeutic ultrasound in vasculature of experimental muscular lesions in rabbits

Valdeci Carlos Dionísio 12 August 1998 (has links)
Este estudo analisou o efeito do ultra-som terapêutico na vascularização pós lesão muscular experimental em coelhos. Foram utilizados 10 coelhos da raça Nova Zelândia, com peso médio de 2,5 kg. Os animais foram submetidos à lesão por esmagamento do músculo reto femoral em ambas as coxas e, após 24 horas um dos lados foi tratado com ultra-som terapêutico e o outro serviu como controle. A freqüência utilizada foi de 1 MHz e intensidade de 0,5 W/cm2 por 5 minutos, durante 10 dias consecutivos. Após 48 horas do término do período de tratamento, os animais foram sacrificados. Foi feita a lavagem do sistema vascular com solução fisiológica, e depois, feita a injeção de uma solução de sulfato de bário e tinta da China. Os músculos foram ressecados do fêmur e submetidos ao processo de diafanização de acordo com a técnica de Spalteholz. Depois que as peças ficaram transparentes, foram examinadas por microscópio cirúrgico. Os resultados não mostraram diferenças no padrão da vascularização (artérias e arteríolas) entre os lados tratados e não tratados, sugerindo que o ultra-som terapêutico não provocou mudanças no padrão vascular após aplicação precoce em lesão muscular. / The effects of therapeutic pulsed ultrasound was investigated on experimental muscular lesions of rabbits. Ten white New Zealand rabbits weighing 2,5 kg were operated on and a crush injury of the rectus femoris of both hind limbs was performed. Twenty-four hours later therapeutic ultrasound was applied on one side and the other side was kept as a control. The following parameters were used: frequency 1 MHz, intensity 0,5 W/cm2, treatment time 5 minutes and a whole of 10 sessions were completed. Two days after completion of the treatment the animals were killed and the arterial system of the hind limbs was injected with a mixture of barium sulphate and Indian ink. The quadriceps was harvested and processed according the Spalteholz technique. The vasculature of the specimens, specially in the local of the injury was studied. The results showed no difference in the vascular pattern between the treated and untreated sides.
83

Determinação simultânea de cobre e chumbo em amostras de azeite de dendê (Elaeis guineensis) por técnicas de redissolução utilizando o método de extração assistida por ultra-som

Cypriano, João Carlos 03 April 2008 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-03T19:35:26Z No. of bitstreams: 1 joaocarloscypriano.pdf: 5678797 bytes, checksum: 96c9bd26976fdfaf6dfc0406946356c2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-13T13:53:49Z (GMT) No. of bitstreams: 1 joaocarloscypriano.pdf: 5678797 bytes, checksum: 96c9bd26976fdfaf6dfc0406946356c2 (MD5) / Made available in DSpace on 2017-05-13T13:53:49Z (GMT). No. of bitstreams: 1 joaocarloscypriano.pdf: 5678797 bytes, checksum: 96c9bd26976fdfaf6dfc0406946356c2 (MD5) Previous issue date: 2008-04-03 / A concentração de traço de metais em óleos vegetais é um critério importante para avaliar a qualidade de óleos com relação à validade, propriedades, armazenamento e influência sobre a nutrição e saúde humana. Neste trabalho, um método eficiente e simples para a determinação de cobre e chumbo em azeite de dendê usando redissolução potenciométrica é proposto. Os íons metálicos foram pré-concentrados como amálgamas na superfície de um eletrodo de carbono vítreo usado como eletrodo de trabalho. Um banho ultrassônico foi utilizado para a extração de cobre e chumbo em onze amostras de azeite de dendê usando uma mistura 1:1 (v/v) de ácido clorídrico concentrado e peróxido de hidrogênio (30 % m/v). Uma eficiência na extração de cobre e chumbo (~ 100 %) foi encontrada após 60 min de exposição à energia ultrassônica. Uma boa relação entre a quantidade de amostra e o tempo necessário para a completa liberação dos metais foi observado. Análises quantitativas foram realizadas através do método de adição de padrão, uma boa linearidade foi obtida na faixa de concentração examinada. Limites de detecção de 150 e 13 ng L-1 foram encontrados para Cu e Pb, respectivamente, nas amostras originais. A faixa de valores encontrados para as amostras analisadas foi de 1,55 a 16,54 µg g-1 para o cobre e 0,04 a 0,37 µg g-1 para o chumbo. As amostras de azeite de dendê foram também analisadas por espectrometria de absorção atômica com forno de grafite (GFAAS), mostrando uma boa correlação entre os resultados. / The concentration of trace metals in vegetable oils is an important criterion for the assessment of oil qualities in regard of freshness, keeping properties, storage and their influence on human nutrition and health. In this work, an effective and simple method for the determination of copper and lead in palm oil by potentiometric stripping analysis is proposed. The metals ions were concentrated as their amalgams on the glassy carbon surface of a working electrode that was coated with a thin mercury film. An ultrasonic bath was used for the extraction of copper and lead from eleven oil samples in a mixture 1:1 (v/v) of concentrated hydrochloric acid and hydrogen peroxide. An efficient extraction of copper and lead (∼100 %) was attained after 60 min of ultrasonic pre-treatment. A good relation between the amount of sample and the time necessary for complete liberation of the metals was observed. Quantitative analysis was carried out by the method of standard additions; a good linearity was obtained in the range of the concentrations examined. Detection limits of 150 and 13 ng L-1 were found for Cu and Pb, respectively, in the original samples. The average values found for the analysed samples were in the range 1.55-16.54 µg g-1 for copper and 0.04-0.37 µg g-1 for lead. The palm oil samples were also analyzed by graphite furnace atomic absorption spectrometry (GFAAS), showing a very good correlation between the results.
84

Estudo Doppler com contraste endovenoso em pacientes com suspeita de cancer de prostata

Baracat, Jamal, 1956- 18 May 2001 (has links)
Orientador: Gentil Alves Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-01T19:35:25Z (GMT). No. of bitstreams: 1 Baracat_Jamal_D.pdf: 21593954 bytes, checksum: 013529d3582d075b03cbb5498fc98d61 (MD5) Previous issue date: 2001 / Resumo: o objetivo deste estudo foi avaliar o papel do agente de contraste ultrasonográfico (Levovist 'TRADE MARK'), através do estudo Doppler e power Doppler, na detecção de cânceres prostáticos em pacientes com suspeita clínica e/ou laboratorial de câncer prostático. Os critérios de inclusão neste estudo foram pacientes com suspeita clínica e/ou laboratorial de câncer prostático. Trinta e nove pacientes apresentaram ou dosagem sérica de PSA > 4,0 ng/rnl e/ou toque retal alterado, e um paciente apresentou diagnóstico de neoplasia intraepitelialprostática (NIP), em exame anterior. Um total de quarenta pacientes foi submetido ao estudo trans-retal em modo B, color Doppler e power Doppler, comparando-se estes métodos, antes e depois da injeção de contraste, usando a biópsia como padrão ouro. Primariamente, todos os pacientes foram submetidos ao estudo ultra-som transretal em modo B, ou na escala de cinza. Uma lesão era considerada anormal caso fosse hipoecogênica, hipercogênica ou apresentasse um padrão misto em relação ao tecido adjacente. Subseqüentemente, nas avaliações pelo estudo color e power Doppler, o fluxo sanguíneo foi subjetivamente classificado em normal ou aumentado, quando comparado ao tecido adjacente ou à região contra-lateral da próstata. Após estas avaliações, foi injetado um agente de contraste endovenoso (Levovist 'TRADE MARK',4g) e observado seu efeito sobre a vasculatura prostática. Foram realizadas biópsias dirigidas em todas as áreas consideradas suspeitas tanto no modo B quanto no estudo color Doppler, power Doppler, com e em contraste, e individualmente correlacionadas com os achados histológicos. Além das biópsias dirigidas, foram efetuadas biópsias aleatórias na zona periférica, em diferentes áreas daquelas consideradas suspeitas ao estudo ultrassonográfico trans-retal, color e power Doppler com e sem contraste. Rotineiramente, utiliza-se a biópsia sextante como padrão das biópsias aleatórias, com duas biópsias na região basal, duas na região média e duas na região apical da próstata, uma de cada lado da próstata. Neste estudo, optou-se pela biópsia octante, com o acréscimo de duas biópsias laterais na região média da próstata. Para a realização das biópsias, foi utilizado um dispositivo automático de disparo, no qual era acoplada uma agulha de calibre 18, para a coleta de material prostático e subseqüente avaliação histológica. Dos 40 pacientes examinados, 13 (32,5%) apresentaram diagnóstico de câncer nos resultados das biópsias. O diagnóstico foi realizado corretamente em 12 pacientes (92%), por todos os métodos (Ultra-som trans-retal, color Doppler epower Doppler), antes e após a injeção de contraste. O contraste (Levovist 'TRADE MARK',4g) aumentou o sinal Doppler e power Doppler da vasculatura prostática em todos os pacientes, tanto nas áreas tumorais, quanto no parênquima prostático normal, mas não demonstrou nenhuma área nova de tumor. Em 11 biópsias aleatórias com câncer, nem o estudo em Modo B, nem o estudo Doppler e power Doppler com e sem contraste evidenciaram estas lesões (isoecogênicas, 29%). As lesões restantes com câncer comprovado pela biópsia eram hipoecogênicas (71%) e todas apresentaram uma vascularização aumentada ao estudo color Doppler e power Doppler. A sensibilidade (8), especificidade (E), acurácia (A), valor preditivo positivo (VPP) e valor preditivo negativo (VPN) foram os seguintes para o ultra-som trans-retal modo B (8= 71,05%, E= 93,55%, A= 90,85%, VPP= 60,00% e VPN= 95,96%), Color Doppler epower Doppler com e sem contraste (8= 71,79%, E= 93,50%, A= 90,82%, VPP= 60,87% e VPN= 95,96%) e o toque retal (8= 50,00%, E= 55,56%, A= 53,85%, VPP= 33,33% e VPN= 71,43%). Quanto à biópsia octante, o acréscimo de duas biópsias laterais no campo médio da zona periférica à biópsia sextante aumentou a sensibilidade da biópsia aleatória em 26,3% (10/38 lesões encontradas). Apesar de a injeção do contraste endovenoso realçar, de forma qualitativa, a vasculatura tanto nos locais com cânceres, quanto no parênquima prostático normal e região peri-prostática, não se mostrou útil em detectar novas áreas tumorais. O ultra-som trans-retal, color e power Doppler apresentaram uma sensibilidade semelhante em detectar as áreas com câncer. Em relação às biópsias aleatórias, a biópsia octante mostrou-se mais sensível que a biópsia sextante / Abstract: The aim of this study was to assess the role of an ultrasound contrast agent (Levovist 'TRADE MARK') in revealing prostatic cancer in patients submitted to trans-rectal color Doppler, power Doppler and biopsy, comparing these methods before and after the injection of contrast agent, using biopsy as the reference standard. Forty patients with prostate-related symptoms underwent a serum prostate specific antigen (PSA) determination or digital rectal examination. Thirty nine subjects were incIuded on the basis of an elevated PSA, greater than 4.0 nglml (Hybritech Tandem Assay), or on the basis of abnormal digital rectal examination findings, and one patient with a anterior history of prostatic intraepithelial neoplasia (PIN). All these patients were submitted to trans-rectal sonography using gray scale (TRUS), color Doppler and power Doppler scanning before and after the injection of intravenous contrasto Octant biopsy of the outer gland (peripheral zone) was performed, and 1 individual specimen was obtained from the base, 2 from mid gland and 1 from apex of each side of the gland. Targeted biopsies were performed if an area was classified as abnormal. Gray-scale ultrasound was classified as normal or abnormal at each biopsy site. A normal site was homogeneous in texture. A site was cIassified as abnormal if it was hypoechoic, echogenic or had a mixed pattem (hypo and hyperechoic). Doppler flow was subjectively classified as normal or increased at each biopsy site. All abnormal areas shown on gray scale, color Doppler or power Doppler was targeted and biopsies were performed. Sonographically guided biopsies were performed on all patients with an 18-gauge automated spring-loaded biopsy gun and all imaging and histological findings were individually correlated. Cancer was found in 13 out of 40 patients (32.5%) on TRUS-guided biopsies. The diagnosis was made correctly in 12 out of 13 patients (92%), by ali methods (TRUS, color Doppler and power Doppler) before and after the injection of contrast medium. The contrast agent (Levovist 'TRADE MARK' 400mg) improved the Doppler or pawer Doppler signal in all patients, but did not depict new site of tumor. However, in 11 sites ofproven cancer by octant biopsy, both gray-scale and color Doppler sonography with and without contrast failed to reveal isoechoic lesions (29%). The test results (S= sensitivity, Sp= specificity,A= accuracy, PPV= positive preditive value, NPV= negative predictive value) for the detection of malignance in biopsy specimens were in baseline ultrasound (S= 71.5%, Sp= 93.55%, A= 90.85%, PPV= 60.00% and NPV= 95.96%), and color Doppler and power Doppler with and without ultrasound contrast(S= 71.5%, Sp= 93.55%, A= 90.85%, PPV= 60.00% and NPV= 95.96%). Our study showed that the use of intravascular microbubble contrast agents such as Levovist 'TRADE MARK' improved the Doppler and Power Doppler signal, but did not depict new sites with tumor / Doutorado / Clinica Medica / Doutor em Clínica Médica
85

Simulação e mapeamento de campos ultra-sonicos para caracterização de transdutores utilizando os metodos pontual e angular

Nicacio, Hayram 02 August 2018 (has links)
Orientador : Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-02T10:25:57Z (GMT). No. of bitstreams: 1 Nicacio_Hayram_M.pdf: 3334926 bytes, checksum: 71c210c63dd7508651efef9a5c2f08b2 (MD5) Previous issue date: 2002 / Mestrado
86

Curvas das medidas ultra-sonograficas do colo e segmento uterinos em gestantes de baixo risco

Cursino de Andrade, Kleber, 1961- 03 August 2018 (has links)
Orientador : Jose Guilherme Cecatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T00:12:32Z (GMT). No. of bitstreams: 1 Andrade_KleberCursinode_M.pdf: 3673016 bytes, checksum: 4028dbf9b75da0fd99bb4c9a7d7d8514 (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi elaborar curvas de valores das medidas ultrasonográficas do colo e segmento uterinos e do ângulo formado entre o segmento inferior com o colo, em gestantes de baixo risco, da 12ª à 36ª semana, em função da idade gestacional e associando estes valores com variáveis obstétricas e sóciodemográficas. Antes de iniciar o estudo propriamente dito, realizou-se um estudo piloto envolvendo 38 mulheres com idades gestacionais também entre 12 a 36 semanas, com a intenção de avaliar as variações inter e intra-observador. Foi então realizado um estudo descritivo em uma amostra dependente de 201 gestantes acompanhadas no pré-natal da UNICAMP, com exames ultra-sonográficos transvaginais, repetidos em intervalos regulares de no máximo quatro semanas, totalizando seis avaliações para cada gestante. Foram avaliados: o comprimento do colo uterino, distância da entrada da artéria uterina no colo até o orifício interno, largura do canal cervical, diâmetro ântero-posterior e transverso, volume do colo, espessura do segmento uterino inferior, ângulo entre o colo e segmento e presença de funil resultante da dilatação do orifício interno avaliando seu ângulo. A análise estatística para o estudo piloto foi realizada por meio do cálculo de médias e desviopadrão para cada medida, comparando-se as medidas dos diferentes observadores pela média da diferença das medidas, percentual de variação, teste t de Student e pela estimativa do coeficiente de correlação linear. Para o total de 172 casos que completaram o estudo, estimou-se a mediana (percentil 50) de cada medida em cada faixa de idade gestacional, com intervalo de confiança de 95% determinando os limites máximos (percentil 97,5) e mínimo (percentil 2,5) e dos percentis 10 e 90 da curva. A variação ao longo do tempo foi avaliada por meio de análise de variância múltipla. Os valores médios de algumas medidas foram comparados entre as principais categorias das variáveis de controle pelo teste t de Student. Houve diminuição significativa do comprimento do colo uterino e da espessura do segmento inferior com o passar da idade gestacional. A medida do diâmetro ântero-posterior e do transverso, o ângulo formado entre o colo e segmento uterino e o volume do colo uterino mostraram um aumento significativo com a evolução da idade gestacional. Não apresentaram variações significativas ao longo da gestação a largura do canal da cérvice e a distância da artéria uterina ao orifício interno. Também não houve variação significativa das medidas pelas variáveis de controle, à exceção do comprimento do colo e o diâmetro ântero-posterior que aumentaram com a paridade. Assim, conclui-se que as modificações da cérvice que se esperam com o passar da gestação são um encurtamento e alargamento do colo, sem alteração do seu volume, e um adelgaçamento do segmento inferior do útero. Os valores do percentil 2,5 ou 10 do volume ou comprimento do colo uterino, para cada idade gestacional, poderiam ser utilizados como limite de normalidade da cérvice na gestação / Abstract: The purpose of this study was to elaborate curves for the ultrasound measures¿ values of the cervix and uterine lower segment and also of the internal angle between the lower segment and the cervix among low risk pregnant women, from the 12th to the 36th week, according to the gestational age and associating these values with obstetrical and socio-demographic variables. Before starting the study itself, a pilot study had been performed with 38 women between 12 and 36 weeks of gestation, with the objective of evaluating the inter and intra-observer variations. A descriptive study was then carried out in a dependent sample of 201 pregnant women followed at the pre natal care service of UNICAMP with transvaginal ultrasound exams, repeated at regular intervals of 4 weeks maximum, with a total of 6 exames for each woman. The cervix length, the distance between the uterine artery entry in the cervix until the internal os, the width of the cervical channel, the anteroposterior and transverse cervical diameter, the volume of the cervix, the width of the lower uterine segment, the angle between the cervix and the segment, and the presence of a funnel resulting from the dilatation of internal os were evaluated. The statistical analysis for the pilot study was carried out through calculation of means and standard deviation for each measure, comparing the values of different observers by the mean differences, percentage of variation, Student t test and estimating the linear correlation coefficient. For the total of 172 cases who completed the study it was estimated the median (50 percentil) for each measure in each gestational age group, with the 95% confidence interval determining the upper (97.5 percentil) and lower (2.5 percentil) limits and also the percentiles 10 and 90 of the curves. The variation of these values across time was evaluated through the multiple analysis of variance. The mean values of some measures were compared between the main categories of control variables by the Student t test. There was a significant decrease of cervical length and the lower uterine segment width with the increase of gestational age. The measure of the anteroposterior and transverse cervical diameters, the angle between the uterine cervix and segment and the volume of the cervix showed a significant increase with gestational age. The cervical channel width and the distance between uterine artery entry in the cervix until the internal os had no significant variation across time of pregnancy. There was also not any significant variation of the measures by the control variables, with exception of the cervix length and the anteroposterior cervical diameter which increased with parity. Therefore, it was concluded that the expected cervical modifications during gestation are a shortening and an enlargement of the cervix, without any alteration of its volume, and a thinning of the lower uterine segment of the uterus. The values of percentiles 2.5 or 10 of the cervix volume or length for each gestational age group could be used as a limit for cervical normality during pregnancy / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
87

Determinação das constantes acustoelasticas para aço API 5 L-X70 para gasodutos

Caetano, Sidney Felix 04 August 2003 (has links)
Orientador: Auteliano Antunes dos Santos Jumior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T16:32:15Z (GMT). No. of bitstreams: 1 Caetano_SidneyFelix_M.pdf: 12116123 bytes, checksum: 07628d4ded75739dba5ca4dd1d067e00 (MD5) Previous issue date: 2003 / Resumo: A confecção de dutos petrolíferos terrestres é feita soldando tubos seqüencialmente. No Brasil, o processo de soldagem é manual e feito com eletrodos revestidos. Processos de soldagem normalmente introduzem tensões residuais nos componentes soldados. Com a finalidade de avaliar as tensões residuais introduzidas pela soldagem, um dos métodos mais promissores é o que as relaciona linearmente com a variação da velocidade de ondas ultra-sônicas. A sensibilidade à variação de tensões é maior com ondas transversais, utilizando o conceito de birefringência, e ondas longitudinais criticamente refratadas. A relação entre a variação da tensão e a variação de velocidades é denominada constante acustoelástica. Este trabalho tem como objetivo a obtenção dos valores das constantes acustoelásticas para ondas longitudinais e transversais para o aço API 5 L - X70, utilizado na construção de gasodutos e oleodutos. Foi ensaiado um conjunto de amostras, parte das quais sofreu alívio prévio de tensões para verificar seu efeito. Também foi analisado o efeito da direção de laminação sobre os resultados. Os testes foram realizados em uma máquina de tração especialmente construída para avaliação em laboratório. Os resultados mostraram que os valores obtidos com a metodologia utilizada têm baixa dispersão e que o método pode ser desenvolvido para futuras aplicações na avaliação de tensões no campo / Abstract: Gas pipelines are made welding tubes in line. The process used in Brazil is arc nelding, with electric weld and consumable electrode. Welding process usually introduce residual stresses in the joint. One of the methods to evaluate that residual stress is to relate the stress variation with the changes in ultrasonic waves speed. The best sensitivity can be got with shear waves, using birefringence method, or longitudinal critically refracted waves. The relation between the variation of stresses and waves speed is called acoustoelastic constants. This work aims to obtain the values for acoustoelastic constants using both, longitudinal and birefringence methods for API 5L x70 steel, witch is used in oil and gas pipelines fabrication. Several samples were tested, both as welded and after a stress relief procedure, to check the internal stresses influence. The influence of the rolling direction was also checked. The tests were run using a tensile stress machine specia1ly built to apply force to the samples. The results showed that the values have low dispersion and that the method can be used to evaluate stresses in API steels and that can be developed to future applications to evaluate stresses in field / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
88

Avaliação de tensões por ultra-som no aro e rodas ferroviarias forjadas novas : classe C

Minicucci, Domingos Jose 03 August 2018 (has links)
Orientador: Auteliano Antunes Santos Jr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T18:41:23Z (GMT). No. of bitstreams: 1 Minicucci_DomingosJose_M.pdf: 10377166 bytes, checksum: 2b292c103ec9f2237e4a795f1d5041de (MD5) Previous issue date: 2003 / Mestrado
89

Sistema ultra-sonico dopler pulsatil para medição de fluxo sanguineo em circulação extracorporea

Dantas, Ricardo Grossi, 1974- 22 April 1999 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T08:36:04Z (GMT). No. of bitstreams: 1 Dantas_RicardoGrossi_M.pdf: 7105342 bytes, checksum: 54d821c8ddbe041c7401811d9837aee2 (MD5) Previous issue date: 1999 / Resumo: Em operações cardíacas, freqüentemente há a necessidade de se realizar intervenções em estruturas internas do coração, e a circulação e oxigenação do sangue são feitas por meios artificiais, fora do corpo do paciente, em um procedimento denominado circulação extracorpórea (CEC) ou "bypass" cardio-pulmonar. Durante uma rotina de CEC, um dos parâmetros mais importantes, e que exige constante monitoração, é o fluxo sangüíneo. Em muitos casos, são utilizados estimadores de fluxo baseados na velocidade de rotação das bombas (peristálticas) ou medidores que utilizam o princípio eletromagnético (bombas peristálticas ou centrífugas). Estes métodos são de tecnologia bastante difundida, mas nem sempre confiáveis para sistemas de CEC, em função de suas características intrínsecas. Neste trabalho, foi desenvolvido um medidor de fluxo sangüíneo baseado no sistema ultra-sônico Doppler pulsátil destinado a sistemas de circulação extracorpórea. Foi utilizado um transdutor de 2MHz, medindo vazões de O a 5 litros/min, acoplado externamente à linha arterial de tubulação de CEC destinada à perfusão de adultos (9,53mm de diâmetro), com a vantagem de não entrar em contato com o sangue do paciente. Este medidor apresenta o valor do fluxo em um indicador numérico de 2 dígitos, disponibilizando esta informação também de forma analógica ou digital, esta última com resolução de 8 bits. Testes realizados indicaram um desvio máximo de 3,5% do fundo de escala. Este medidor fornece resultados de forma contínua e confiável, e não apresenta as limitações encontradas nos outros métodos. Além disso, pelo fato de não haver contato com o sangue, ele não é descartável e não necessita de esterilização, reduzindo custos operacionais e viabilizando seu uso / Abstract: : In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient' s body, in a procedure known as extracorporeal circulation (EC) or heart-lung bypass. During an EC procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. Quite often, blood flow estimators based in the pump rotation speed (for peristaltic pumps) or those using the electromagnetic principle (for peristaltic or centrifugal pumps) are used. The technology available for these methods is relatively well known, but not very reliable for EC systems due to their intrinsic characteristics. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53mm or 3/8"), with the advantage of not entering in contact with the patient blood. This flowmeter presents the flow value in a 2 digit numerical display, allowing this information to be used both in analog and digital forms (8 bits resolution). The results indicated a maximum deviation of3.5% of full scale. This flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
90

Projeto de um sistema ultra-sonico doppler pulsatil para avaliação da vascularização periferica

Gamba, Humberto R 09 June 1989 (has links)
Orientador : Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T20:51:19Z (GMT). No. of bitstreams: 1 Gamba_HumbertoR_M.pdf: 9020235 bytes, checksum: f58f0f0b6af91cdd429e14d1ee2e9ab9 (MD5) Previous issue date: 1989 / Resumo: A utilização de sistemas ultra-sônicos, baseados no princrpio Doppler, para detecção de estenoses arteriais, constitui uma área de grande interesse no diagnóstico médico. Os equipamentos de fabricação nacional para esta finalidade trabalham com emissão e recepção de ultra-som no modo contínuo. Devido à esta característica, estes sistemas só conseguem detectar a existência de turbulências produzidas por obstruções que comprometem praticamente 50 % da luz do vaso. Os Com a finalidade de detectar a presença de turbulências produzidas por estenoses de pequeno grau (menores que 30%), projetou-se e construiu-se a primeira parte de um sistema ultra-sônico Doppler pulsátiI de múltiplos canais. O protótipo, embora ainda com apenas um canal , é capaz de analisar lâminas de fluxo com espessura de aproximadamente 2,3 mm (ângulo de incidência de 75 graus) em profundidades de até 70 mm. Seu sistema de controle permite a ampliação até o máximo de 15 canais. O transdutor utilizado neste equipamento possui um único cristal, tanto para emissão quanto para recepção, emitindo pulsos ultra-sônicos de 5 MHz em intervalos fixos de 50 µ ou 100 , sendo a duração de cada pulso ajustável entre 0,1 e 1 µ . Os resultados obtidos com este primeiro protótipo, demonstram a capacidade do sistema em detectar turbulências produzidas por obstruções de até 22 % de comprometimento da luz do vaso / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0397 seconds