Noninvasive ultrasound elastography of atherosclerotic vascular disease : methods and clinical evaluation /Shamdasani, Vijay Thakur. January 2008 (has links)
Thesis (Ph. D.)--University of Washington, 2008. / Vita. Includes bibliographical references (leaves 88-100).
|
2 |
The effectiveness of color power angiography in differentiation of focal hepatic lesions.January 1998 (has links)
by Young Lee Kei, Ricky. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1998. / Includes bibliographical references (leaves 205-207). / Abstract also in Chinese. / Acknowledgements --- p.i / Statement of Originality --- p.ii / Abstract --- p.iii / Chapter Chapter 1 --- Introduction / Chapter 1.1 --- Anatomy of liver --- p.1 / Chapter 1.2 --- Anatomical Implications --- p.16 / Chapter Chapter 2 --- Background / Chapter 2.1 --- Common focal hepatic lesions --- p.21 / Chapter 2.2 --- Imaging techniques --- p.28 / Chapter 2.3 --- Characterization by sonography --- p.34 / Chapter 2.4 --- Color Power Angiography --- p.38 / Chapter Chapter 3 --- Hypothesis & Aims / Chapter 3.1 --- Hypothesis --- p.44 / Chapter 3.2 --- Aims & Objectives --- p.45 / Chapter Chapter 4 --- Material and Methods / Chapter 4.1 --- Materials --- p.47 / Chapter 4.2 --- Mode of confirmation --- p.52 / Chapter 4.3 --- Final number of subjects recruited --- p.54 / Chapter 4.4 --- Method for obtaining CD and CPA image --- p.58 / Chapter 4.5 --- Method for image analysis --- p.61 / Chapter 4.6 --- Statistical analysis --- p.68 / Chapter Chapter 5 --- Results / Chapter 5.1 --- Qualitative CD and CPA images assessment --- p.70 / Chapter 5.2 --- Interobserver qualitative analysis --- p.78 / Chapter 5.3 --- Spectral analysis --- p.84 / Chapter 5.4 --- Semi-quantitative signal parameters --- p.87 / Chapter 5.5 --- Dominance of quantified signals --- p.91 / Chapter 5.6 --- Distribution of signals in various lesions (graphical presentation) --- p.97 / Chapter 5.7 --- Penetrating vessel --- p.103 / Chapter 5.8 --- Relationship between size of lesion and quantified signal parameters --- p.104 / Chapter Chapter 6 --- Discussion / Chapter 6.1 --- Study Review --- p.109 / Chapter 6.2 --- Methods of quantitation --- p.110 / Chapter 6.3 --- Value of quantitation --- p.111 / Chapter 6.4 --- Instrumentation --- p.112 / Chapter 6.5 --- Subjects --- p.114 / Chapter 6.6 --- Image analysis --- p.115 / Chapter 6.7 --- Results --- p.117 / Chapter 6.8 --- Relationship between size and amount of signals --- p.131 / Chapter 6.9 --- Differentiation of focal hepatic lesions --- p.132 / Chapter 6.10 --- Origin of CPA signals in small hyperechoic lesions --- p.144 / Chapter 6.11 --- Limitations of CPA in focal hepatic lesion imaging --- p.146 / Chapter 6.12 --- Comparison with similar studies --- p.151 / Chapter 6.13 --- Validation of quantitation results --- p.158 / Chapter Chapter 7 --- Conclusions --- p.159 / References --- p.162 / Legends --- p.176 / Tables --- p.186 / Glossary of abbreviations --- p.193 / Selected publications relevant to thesis --- p.197 / Appendix --- p.198 / Bibliography --- p.205
|
3 |
Predição da pré-eclâmpsia pelo estudo dopplervelocimétrico endovaginal das artérias uterinas entre 11-13 e 20-24 semanas de gestação / Screening for pre-eclampsia by transvaginal uterine artery Doppler at 11-13 and 20-24 weeks gestationLiao, Adolfo Wenjaw 15 August 2007 (has links)
Estudo realizado na Clínica Obstétrica da Faculdade de Medicina da Universidade de São Paulo, com seiscentos e quarenta e cinco gestantes recrutadas, prospectivamente, para avaliações dopplervelocimétricas das artérias uterinas, por via endovaginal, entre 11 e 13+6 semanas e entre 20 e 24+6 semanas. A partir de um grupo de 344 casos com desfecho normal da gestação, valores de referências para os índices dopplervelocimétricos médios foram estabelecidos, e estes foram significativamente maiores na primeira avaliação do que na segunda. Além disso, os valores se correlacionaram de forma positiva e significativa (IP r= 0,42, IR r= 0,42, AB r= 0,29, p<0,0001). Incisura uterina bilateral foi encontrada em 43,9% dos casos no primeiro exame e 4,4% na segunda etapa. Também foram descritos os valores de sensibilidade, especificidade, valores preditivos, razão de verossimilhança e risco relativo de diferentes parâmetros dopplervelocimétricos para predição da pré-eclâmpsia, diagnosticada em 25 casos. Entre 11 e 13 sem. + 6 dias, as áreas sob as curvas de caracterísiticas operacionais dos três índices dopplervelocimétricos foram de 0,51. A maioria dos achados dopplervelocimétricos, nesta fase da gestação, não identificou gestações com risco significativamente aumentado para pré-eclâmpsia. Já, entre 20 e 24 sem. + 6 dias, as áreas sob as curvas de características operacionais foram maiores (IP= 0,66, IR= 0,65, AB= 0,65) e o grupo com índices dopplervelocimétricos acima do percentil 85 e/ou incisura bilateral apresentou risco significativamente aumentado, para o posterior surgimento de pré-eclâmpsia na gestação. Entretanto, a sensibilidade e o valor preditivo positivo foram baixos, e não encorajam o uso desse método para predição da doença hipertensiva específica da gestação em nossa população. / At São Paulo University Medical School, six hundred and forty five pregnant women were prospectively recruited for a longitudinal study involving transvaginal uterine artery Doppler assessment at 11?13+6 weeks and 20?24+6 weeks. Reference values for mean uterine artery Doppler indices were established from 344 cases with normal pregnancy outcome. Values found in the first examination were significantly higher and positively correlated to values obtained in the second examination (PI r= 0.42, RI r= 0.42, SD r= 0.29, p<0.0001). Bilateral notches were found in 43.9% of the cases examined between 11 and 13 weeks, and 4.4% of the cases in the second assessment. Twenty-five cases subsequently developed pre-eclampsia. Sensitivity, specificity, positive and negative predictive values, likelihood ratios and relative risks were calculated for various uterine artery Doppler findings. Between 11 and 13+6 weeks, the ROC curve area was 0.51 for all three indices. At this stage, most uterine artery Doppler findings were not associated with increased risk of pre-eclampsia. At 20 to 20+6 weeks, ROC curve areas were higher (PI= 0.66, RI= 0.65, SD= 0.65) and increased impedance to flow (above the 85th centile) and/or bilateral notches were associated with a significant increase of the risk for the subsequent development of pre-eclampsia. However low sensitivity and positive predictive values do not support this as a screening method for pre-eclampsia in our population.
|
4 |
Predição da pré-eclâmpsia pelo estudo dopplervelocimétrico endovaginal das artérias uterinas entre 11-13 e 20-24 semanas de gestação / Screening for pre-eclampsia by transvaginal uterine artery Doppler at 11-13 and 20-24 weeks gestationAdolfo Wenjaw Liao 15 August 2007 (has links)
Estudo realizado na Clínica Obstétrica da Faculdade de Medicina da Universidade de São Paulo, com seiscentos e quarenta e cinco gestantes recrutadas, prospectivamente, para avaliações dopplervelocimétricas das artérias uterinas, por via endovaginal, entre 11 e 13+6 semanas e entre 20 e 24+6 semanas. A partir de um grupo de 344 casos com desfecho normal da gestação, valores de referências para os índices dopplervelocimétricos médios foram estabelecidos, e estes foram significativamente maiores na primeira avaliação do que na segunda. Além disso, os valores se correlacionaram de forma positiva e significativa (IP r= 0,42, IR r= 0,42, AB r= 0,29, p<0,0001). Incisura uterina bilateral foi encontrada em 43,9% dos casos no primeiro exame e 4,4% na segunda etapa. Também foram descritos os valores de sensibilidade, especificidade, valores preditivos, razão de verossimilhança e risco relativo de diferentes parâmetros dopplervelocimétricos para predição da pré-eclâmpsia, diagnosticada em 25 casos. Entre 11 e 13 sem. + 6 dias, as áreas sob as curvas de caracterísiticas operacionais dos três índices dopplervelocimétricos foram de 0,51. A maioria dos achados dopplervelocimétricos, nesta fase da gestação, não identificou gestações com risco significativamente aumentado para pré-eclâmpsia. Já, entre 20 e 24 sem. + 6 dias, as áreas sob as curvas de características operacionais foram maiores (IP= 0,66, IR= 0,65, AB= 0,65) e o grupo com índices dopplervelocimétricos acima do percentil 85 e/ou incisura bilateral apresentou risco significativamente aumentado, para o posterior surgimento de pré-eclâmpsia na gestação. Entretanto, a sensibilidade e o valor preditivo positivo foram baixos, e não encorajam o uso desse método para predição da doença hipertensiva específica da gestação em nossa população. / At São Paulo University Medical School, six hundred and forty five pregnant women were prospectively recruited for a longitudinal study involving transvaginal uterine artery Doppler assessment at 11?13+6 weeks and 20?24+6 weeks. Reference values for mean uterine artery Doppler indices were established from 344 cases with normal pregnancy outcome. Values found in the first examination were significantly higher and positively correlated to values obtained in the second examination (PI r= 0.42, RI r= 0.42, SD r= 0.29, p<0.0001). Bilateral notches were found in 43.9% of the cases examined between 11 and 13 weeks, and 4.4% of the cases in the second assessment. Twenty-five cases subsequently developed pre-eclampsia. Sensitivity, specificity, positive and negative predictive values, likelihood ratios and relative risks were calculated for various uterine artery Doppler findings. Between 11 and 13+6 weeks, the ROC curve area was 0.51 for all three indices. At this stage, most uterine artery Doppler findings were not associated with increased risk of pre-eclampsia. At 20 to 20+6 weeks, ROC curve areas were higher (PI= 0.66, RI= 0.65, SD= 0.65) and increased impedance to flow (above the 85th centile) and/or bilateral notches were associated with a significant increase of the risk for the subsequent development of pre-eclampsia. However low sensitivity and positive predictive values do not support this as a screening method for pre-eclampsia in our population.
|
5 |
Značaj tumorskih markera CA125 i HE4, konvencionalne i dopler transvaginalne sonografije u dijagnostici karcinoma jajnika / The importance of tumor markers CA125 and HE4, conventional and Doppler transvaginal ultrasound in diagnosis of ovarian cancerPantelić Miloš 10 June 2016 (has links)
<p>Uvod: Karcinom jajnika predstavlja značajan zdravstveni problem.Karakteriše ga najveća smrtnost od svih ginekoloških maligniteta. Najveći broj slučajeva karcinoma jajnika dijagostikuje se u uznapredovalim stadijumima bolesti (FIGO st. III i IV), kod kojih petogodišnje preživljavanje iznosi ispod 30%, dok se svega 25% slučajeva otkrije u prvom stadijumu gde petogodišnje preživljavanje iznosi preko 90%. Do danas nije otkrivena dijagnostička metoda za rano otkrivanje početnog karcinoma jajnika u opštoj populaciji koja je dovoljno osetljiva i specifična da bi se koristila kao „screening“ metoda. Uspeh u lečenju karcinoma jajnika direktno zavisi od rano postavljene dijagnoze. Cilj istraživanja: Utvrditi značaj tumorskih markera Ca125, HE4, Roma indexa, konvencionalne i dopler transvaginalne sonografije u dijagnostici karcinoma jajnika. Metodologija: Istraživanje je sprovedeno kao prospektivna klinička studija, na Klinici za ginekologiju i akušerstvo u Novom Sadu. Ispitivanjem je obuhvaćeno 238 pacijenktinja sa adneksalnim tumorom za operativno lečenje. Preoperativno svim pacijentkinjama je uzeta detaljna anamneza, urađen konvencionalni i dopler transvaginalni ultrazvučni pregled i uzeta krv za određivanje tumorskih markera CA125, HE4, Roma indexa. U zavisnosti od definitivnog patohistološkog nalaza pacijentkinje su podeljene u dve grupe. Grupu A ili ispitivanu grupu su činile ispitanice sa karcinomom i border line tumorima,a grupu B ili kontrolnu grupu,pacijentkinje sa benignim tumorima jajnika. Rezultati: Prosečna starost pacijentkinja je 53 godine. U ukupnom ispitivanom uzorku bilo je statistički značajno više pacijentkinja u premenopauzi(59,2%) u odnosu na postmenopauzalne pacijentkinje. U ispitivanoj grupi najčešće zastupljen patohistološki tip karcinoma je high-grade serozni cistadenokarcinom. Kod najvećeg broja pacijentkinja(49,4%) karcinom je dijagnostikovan u I stadijumu bolesti. U diferencijaciji karcinoma jajnika i benignih tumora jajnika, AUC vrednosti za HE4,Ca125 i Roma index su 0.933, 0.831 i 0.932. Senzitivnost HE4,Ca125,Roma indexa iznosi 0.797/ 0.734 / 0.823. Specifičnost HE4,Ca125, Roma indexa je 0.881 / 0.838 / 0.774. Senzitivnost konvencionalne i dopler transvaginalne sonografije je 0,937/ 0,750, a specifičnost je 0,736/ 0,931 respektivno.Kod pacijentkinja sa endometriozom, vrednost tumorskog markera HE4 je povišena samo kod 6% pacijentkinja, za razliku od vrednosti Ca125 koje su povišene kod 76% pacijentkinja sa endometriozom. Zaključak: Najsnažniji prediktori u diferencijaciji karcinoma od benignih tumora jajnika su: tumorski marker HE4, Roma index, indeks otpora protoku krvi kroz tumorsko tkivo (RI), neravan unutrašnji zid tumora i ekrescencije unutar tumora. Najbolju senzitivnost u detekciji karcinoma jajnika pokazala je konvencionalna transvaginalna sonografija u odnosu na druge dve ispitivane metode, dok najbolju specifičnost u odvajanju benignih tumora od karcinoma jajnika pokazuje dopler transvaginalna sonografija.</p> / <p>Background: Ovarian cancer represents very important world health issue. It is characterized by the highest mortality rate of all gynecological malignancies. The majority of ovarian cancer cases are diagnosed in advanced stages (FIGO III and IV) in which 5 year survival rate is less than 30%, and only 25% of cases are diagnosed in stage I with survival rate of 90%. So far no diagnostic method has been discovered that is specific and accurate enough to diagnose ovarian cancer in early stage in general population, so that it can be used as screening method. Success rate of treatment of ovarian cancer is dependent on the stage in which the diagnosis has been made. Objective: to determine the importance of tumor markers CA 125, HE4, Roma index, conventional and Doppler transvaginal ultrasound in diagnosis of ovarian cancer. Method: Research was undertaken as prospective study at Clinic for Gynecology and Obstetrics in Novi Sad. The analysis included 238 women with adnexal tumors indicated for surgery. Preoperatively detailed medical history, blood analysis (CA125,HE4,ROMA index), conventional and Doppler transvaginal ultrasound were done for all patients. Patients were divided into two groups depending on their definite pathohistological finding. Group A included patients with carcinoma and border line tumors. Group B (control group) included patients with benign ovarian tumors. Results: Average age of patient was 53 years. More patients were premenopausal (59.2%). The most frequent pathohistological type of carcinoma was high grade serous cystadenocarcinoma. In most cases diagnosis was made in stage I (49.4%). In differentiation between ovarian carcinoma and benign ovarian tumors AUC for HE4, Ca125and Roma index were 0.933,0.831,0.932. Sensitivity of HE4,Ca125 and Roma index is 0.797,0.734,0.832. Specificity of HE4,Ca125 and Roma index is 0.881,0.838,0.774. Sensitivity of conventional and transvaginal ultrasound is 0.937, 0.750, and specificity is 0.736 and 0.931 respectively. In patients with endometriosis tumor marker HE4 levels were elevated in only 6% of cases, while Ca125 levels were elevated in 76% of cases. Conclusion: The most important predictors in carcinoma/benign tumor differentiation are tumor markers HE4, Roma index, RI, uneven inner walls of tumor and ekrescency inside tumor. The highest sensitivity in ovarian cancer detection showed conventional transvaginal ultrasound when compared to two other used methods. The highest specificity in carcinoma/bening tumor differentiation showed doppler transvaginal ultrasound.</p>
|
6 |
Circulação venosa fetal em gestações gemelares monocoriônicas com insuficiência placentária / Fetal venous circulation in monochorionic twin pregnancies with placental insufficiencyLiao, Tatiana Bernath 12 June 2013 (has links)
Objetivo: A finalidade deste estudo foi avaliar o Doppler venoso em gestações gemelares monocoriônicas (MC) com insuficiência placentária e a relação do fluxo sanguíneo venoso com a acidemia no nascimento ou óbito fetal. Método: Estudo prospectivo que incluiu 18 gestações gemelares MC com insuficiência placentária. Os critérios de inclusão foram: gestação gemelar MC e diamniótica, dopplervelocimetria da artéria umbilical (AU) alterada, membranas integras e ausência de defeitos congênitos fetais. Casos que apresentassem a síndrome de transfusão feto- fetal foram excluídos. Os seguintes parâmetros de Doppler foram avaliados: índice de pulsatilidade (IP) da AU, índice de pulsatilidade para veias (IPV) do ducto venoso (DV), IP e velocidade sistólica máxima (Vmax) da artéria cerebral média (ACM), a média da velocidade máxima (TAMxV) da veia umbilical (VU) e a TAMxV da veia portal esquerda (VPE). Os parâmetros dopplervelocimétricos foram transformados em escore zeta (desvios padrão da média) ou múltiplos da mediana (MoM), de acordo com os valores de referência. Amostras de sangue do cordão umbilical foram obtidas imediatamente após o parto para a mensuração do pH da artéria umbilical no nascimento. Resultado: O pH < 7,20 ocorreu em nove recém nascidos (25%), pH< 7,15 em quatro (11,1%) e em quatro (11,1%) casos houve óbito intrauterino. Os escores zeta da TAMxV da VU e da VPE foram significativamente menores no grupo com pH < 7,2 ou óbito intrauterino (respectivamente: -1,79 vs. - 1,22, p=0,006; -2,26 vs. -1,13, p=0,04). Nos casos com pH< 7,15 ou óbito intrauterino a pulsação da VU foi mais frequente (50% vs. 10,7%, p=0,03) e a TAMxV da VU foi significativamente mais baixa (-1,89 vs. -1,26, p= 0,003). A análise de regressão logística demonstrou que o escore zeta da TAMxV da VU prediz significativamente acidemia com pH< 7,20 ou óbito intrauterino (p=0,019). O parâmetro de Doppler que prediz significativamente pH< 7,15 ou óbito intrauterino foi a pulsação da VU (p=0,023). Conclusão: Os parâmetros de Doppler da VU podem predizer a acidemia no nascimento ou o óbito fetal em gestações gemelares MC complicadas por insuficiência placentária / Objectives: The aim of this study was to investigate fetal venous Doppler in monochorionic (MC) twin pregnancies complicated by placental insufficiency and the relationship between fetal venous flow and acidemia at birth or intrauterine fetal death. Methods: This was a prospective study of 18 MC twin pregnancies with placental insufficiency. Inclusion criteria were MC diamniotic twin pregnancies, abnormal umbilical artery (UA) Doppler, intact membranes, and absence of fetal congenital abnormalities. The twin-to-twin transfusion syndrome cases were excluded. The following Doppler measurements were studied: UA pulsatility index (PI), ductus venosus (DV) pulsatility index for veins (PIV), middle cerebral artery (MCA) PI and peak systolic velocity (PSV), intra-abdominal umbilical vein (UV) timeaveraged maximum velocity (TAMxV), and left portal vein (LPV) TAMxV. Doppler parameters were transformed into z-scores (SD values from the mean) or multiples of median (MoM) according to normative references. Blood samples were obtained from the umbilical cord immediately after delivery to measure the pH of the umbilical artery at birth. Results: pH<7.20 occurred in 9 newborns (25%), pH<7.15 in 4 (11.1%), and intrauterine fetal death in 4 (11.1%). The UV-TAMxV and the LPVTAMxV z-scores were significantly lower in the group presenting pH <7.20 or intrauterine fetal death (respectively: -1.79 vs. -1.22, p=0.006; -2.26 vs. -1.13, p=0.04). In cases with pH <7.15 or intrauterine fetal death, UV pulsations were more frequent (50% vs. 10.7%, p=0.03) and the UV-TAMxV z-score was significantly lower (-1.89 vs. -1.26, p=0.003). Logistic regression demonstrated that the UVTAMxV z-score significantly predicted pH at birth <7.20 or intrauterine fetal death (p=0.019). The Doppler parameter which independently predicted pH < 7.15 or intrauterine fetal death was the presence of pulsation in the umbilical vein (p=0.023). Conclusion: UV Doppler parameters may predict acidemia at birth or intrauterine fetal death in MC twins complicated by placental insufficiency
|
7 |
Correlação entre a ressonância magnética e a ultra-sonografia com duplex scan colorido no diagnóstico da trombose venosa profunda dos membros inferiores / Correlation between magnetic resonance and duplex color sonography in diagnosis of deep venous thrombosis in lower limbsAndrade Neto, Flávio Mendes de 07 May 2007 (has links)
A trombose venosa profunda é uma doença que acomete o sistema venoso profundo, com formação de trombos dentro de uma veia e conseqüente reação inflamatória do vaso. O trombo pode determinar a obstrução parcial ou total do vaso. Ocorre em maior número nos membros inferiores e pelve. O quadro normalmente é agudo, mas pode se tornar crônico, com recidivas. Na maior parte dos casos, acomete os membros de forma unilateral. No presente estudo, foram utilizados dois métodos de diagnóstico por imagem na detecção de trombose venosa profunda, que foram a ultra-sonografia em escala de cinza (modo B) associada ao Duplex Scan colorido, e a ressonância magnética. Neste último, foi utilizado meio de contraste paramagnético (Gadolínio) através de administração venosa pediosa. Foram estudados um total de 26 pacientes, 47 membros inferiores e 141 segmentos corporais. A comparação entre os métodos de imagem foi feita por segmento venoso e por segmento corporal. O objetivo do estudo foi avaliar a concordância diagnóstica entre os métodos e a confiabilidade interobservadores nos exames de ressonância magnética, bem como avaliar a sensibilidade, especificidade e acurácia do Duplex Scan colorido em relação à ressonância magnética por segmentos venosos e corporais. Como conclusões do estudo, notamos que houve boa correlação entre a ultrasonografia e a ressonância magnética nos segmentos femorais comuns e superficiais, perfurantes da coxa, poplíteas, tibiais posteriores, fibulares e ilíacas externas. Também houve boa correlação entre os métodos na avaliação das coxas e pernas, e ausência de correlação significativa na pelve. Houve boa confiabilidade interobservadores nos exames de ressonância magnética por segmento venoso. A sensibilidade da ultrasonografia em relação à ressonância magnética foi excelente na pelve, coxas e pernas, sendo a especificidade e acurácia altas na coxa e perna, e baixas na pelve / Deep venous thrombosis is a disease that occurs in deep venous system, with thrombi formation into a vein, and consequent vascular inflammatory reaction. This thrombus can determine partial or total vascular occlusion. It occurs mostly in the lower limbs and pelvis. Clinical presentation is usually acute, but may also be chronic with relapses. In most cases, limb disease is unilateral. In the present study, two different imaging techniques were used in the diagnosis of deep venous thrombosis: B-mode sonography with duplex color Doppler and magnetic resonance imaging with pedal vein administration of paramagnetic contrast media. Twenty-six patients, 47 lower extremities and 141 body segments were evaluated. Comparasion between techniques was made by vascular segments and body segments.The objectives of the study were to evaluate agreement in diagnosis between methods by vascular and body segments, interobserver reliability to read magnetic resonance exams, and sensibility, specificity and accuracy of duplex color sonography in relation to magnetic resonance imaging by vascular and body segments. In conclusion, there was a good correlation between ultrasound and magnetic resonance imaging at common and superficial femoral vein segments, thigh perfurants, calf veins, posterior tibial, fibular and external iliac veins. There was a good correlation between techniques in the evaluation of thighs and legs, but not in the pelvis. There was a good interobserver reliability in the evaluation of vascular segments by magnetic resonance imaging. The sensibility of duplex color sonography in relation to magnetic resonance imaging was excellent in pelvis, thighs and legs; specificity and accuracy were high in thighs and legs, and low in the pelvis
|
8 |
Circulação venosa fetal em gestações gemelares monocoriônicas com insuficiência placentária / Fetal venous circulation in monochorionic twin pregnancies with placental insufficiencyTatiana Bernath Liao 12 June 2013 (has links)
Objetivo: A finalidade deste estudo foi avaliar o Doppler venoso em gestações gemelares monocoriônicas (MC) com insuficiência placentária e a relação do fluxo sanguíneo venoso com a acidemia no nascimento ou óbito fetal. Método: Estudo prospectivo que incluiu 18 gestações gemelares MC com insuficiência placentária. Os critérios de inclusão foram: gestação gemelar MC e diamniótica, dopplervelocimetria da artéria umbilical (AU) alterada, membranas integras e ausência de defeitos congênitos fetais. Casos que apresentassem a síndrome de transfusão feto- fetal foram excluídos. Os seguintes parâmetros de Doppler foram avaliados: índice de pulsatilidade (IP) da AU, índice de pulsatilidade para veias (IPV) do ducto venoso (DV), IP e velocidade sistólica máxima (Vmax) da artéria cerebral média (ACM), a média da velocidade máxima (TAMxV) da veia umbilical (VU) e a TAMxV da veia portal esquerda (VPE). Os parâmetros dopplervelocimétricos foram transformados em escore zeta (desvios padrão da média) ou múltiplos da mediana (MoM), de acordo com os valores de referência. Amostras de sangue do cordão umbilical foram obtidas imediatamente após o parto para a mensuração do pH da artéria umbilical no nascimento. Resultado: O pH < 7,20 ocorreu em nove recém nascidos (25%), pH< 7,15 em quatro (11,1%) e em quatro (11,1%) casos houve óbito intrauterino. Os escores zeta da TAMxV da VU e da VPE foram significativamente menores no grupo com pH < 7,2 ou óbito intrauterino (respectivamente: -1,79 vs. - 1,22, p=0,006; -2,26 vs. -1,13, p=0,04). Nos casos com pH< 7,15 ou óbito intrauterino a pulsação da VU foi mais frequente (50% vs. 10,7%, p=0,03) e a TAMxV da VU foi significativamente mais baixa (-1,89 vs. -1,26, p= 0,003). A análise de regressão logística demonstrou que o escore zeta da TAMxV da VU prediz significativamente acidemia com pH< 7,20 ou óbito intrauterino (p=0,019). O parâmetro de Doppler que prediz significativamente pH< 7,15 ou óbito intrauterino foi a pulsação da VU (p=0,023). Conclusão: Os parâmetros de Doppler da VU podem predizer a acidemia no nascimento ou o óbito fetal em gestações gemelares MC complicadas por insuficiência placentária / Objectives: The aim of this study was to investigate fetal venous Doppler in monochorionic (MC) twin pregnancies complicated by placental insufficiency and the relationship between fetal venous flow and acidemia at birth or intrauterine fetal death. Methods: This was a prospective study of 18 MC twin pregnancies with placental insufficiency. Inclusion criteria were MC diamniotic twin pregnancies, abnormal umbilical artery (UA) Doppler, intact membranes, and absence of fetal congenital abnormalities. The twin-to-twin transfusion syndrome cases were excluded. The following Doppler measurements were studied: UA pulsatility index (PI), ductus venosus (DV) pulsatility index for veins (PIV), middle cerebral artery (MCA) PI and peak systolic velocity (PSV), intra-abdominal umbilical vein (UV) timeaveraged maximum velocity (TAMxV), and left portal vein (LPV) TAMxV. Doppler parameters were transformed into z-scores (SD values from the mean) or multiples of median (MoM) according to normative references. Blood samples were obtained from the umbilical cord immediately after delivery to measure the pH of the umbilical artery at birth. Results: pH<7.20 occurred in 9 newborns (25%), pH<7.15 in 4 (11.1%), and intrauterine fetal death in 4 (11.1%). The UV-TAMxV and the LPVTAMxV z-scores were significantly lower in the group presenting pH <7.20 or intrauterine fetal death (respectively: -1.79 vs. -1.22, p=0.006; -2.26 vs. -1.13, p=0.04). In cases with pH <7.15 or intrauterine fetal death, UV pulsations were more frequent (50% vs. 10.7%, p=0.03) and the UV-TAMxV z-score was significantly lower (-1.89 vs. -1.26, p=0.003). Logistic regression demonstrated that the UVTAMxV z-score significantly predicted pH at birth <7.20 or intrauterine fetal death (p=0.019). The Doppler parameter which independently predicted pH < 7.15 or intrauterine fetal death was the presence of pulsation in the umbilical vein (p=0.023). Conclusion: UV Doppler parameters may predict acidemia at birth or intrauterine fetal death in MC twins complicated by placental insufficiency
|
9 |
Acurária do estudo dos jatos ureterais à ultra-sonografia do Doppler Colorido no diagnóstico das hidronefroses / Diagnostic accuracy of color Doppler sonographic study of the ureteric jets in evaluation of hydronephrosisBessa Junior, José de 10 August 2007 (has links)
Introdução e Objetivo: Hidronefrose e Obstrução são condições associadas, entretanto dilatações da via excretora podem ocorrer na ausência de obstruções clinicamente importantes. Ultra-sonografia convencional e Renograma com Diuréticos são os métodos diagnósticos complementares mais utilizados na avaliação das hidronefroses na infância. Recentes trabalhos têm demonstrado a possibilidade de observarmos os jatos ureterais com o Estudo Ultra-sonográfico com Doppler Colorido e sugerido a sua aplicação no diagnóstico diferencial das hidronefroses. O objetivo do presente trabalho foi avaliar a aplicabilidade do estudo dos jatos ureterais como método diagnóstico na identificação das hidronefroses obstrutivas e não obstrutivas na população pediátrica. Métodos: Foram estudadas 48 crianças (35 meninos e 13 meninas) com idade que variou de um mês a 14 anos (mediana de 4 anos), que se apresentaram com Hidronefroses Unilaterais, Graus III e IV, e com suspeita de obstrução da junção pieloureteral. Todos os sujeitos foram submetidos ao Estudo dos jatos ureterais e ao Renograma com Diuréticos num período de duas semanas. As unidades hidronefróticas foram consideradas obstruídas quando a Função Renal Diferencial era menor do que 40%, ou em indivíduos mais velhos que apresentavam dor lombar intermitente. Os jatos ureterais de cada meato foram contados por um período de 5 minutos e considerados separadamente. Freqüência Relativa dos Jatos (FRJ) foi definida como o numero de jatos ureterais no lado afetado dividido pela soma dos jatos ureterais observados bilateralmente. Resultados: Vinte e duas (45,8%) unidades hidronefróticas foram consideradas obstruídas.A média da FRJ diferiu significativamente entre as hidronefroses obstrutivas (0,09 ± 0,15) e não obstrutivas (0,41 ± 0,11). (p<0.001). Análise da Curva ROC revelou que FRJ < 0,25 é o melhor valor que distingue as hidronefroses obstrutivas e não obstrutivas e o faz corretamente em 91,2 % dos casos, com uma Sensibilidade de 86,4% (IC95%=78,6-98,2%) e Especificidade de of 96.15% (IC95%=87.8-99%). O Índice de Probabilidade Positivo foi de 22,45 e a Razão de Chances Diagnóstica de 158,3. A área sob a curva ROC foi de 0,91 (IC95%=0,86-0,98) indicando a excelente acurácia do método. Conclusões: FRJ < 25 % mostrou ser um bom indicador de obstrução nas hidronefroses unilaterais da infância. O estudo dos jatos ureterais a Ultrasonografia com Doppler Colorido é método simples, não invasivo e pode ser utilizado na abordagem inicial e no seguimento, na diferenciação das hidronefroses obstrutivas e não obstrutivas na população pediátrica / Introduction and Objective: Hydronephrosis (HN) and obstruction are closely associated, but upper urinary tract dilatation can occur without significant obstruction. Despite some pitfalls, conventional ultrasonography and diuretic renography (DR) are the main modalities in the evaluation of HN in children. Recent reports have demonstrated the usefulness of Color Doppler Ultrasonography (CDUS) as a reliable method to identify the ureteric jets (UJ) in the bladder. The aim of this study was to evaluate CDUS evaluation of the UJ in the bladder as a diagnostic tool to distinguish obstructive from non-obstructive dilatations of the upper tract in pediatric population. Methods: We evaluated 48 patients (35 boys and 13 girls), aged 1 month to 14 years (median = 4 ys.), who presented with unilateral grade III and IV hydronephrosis suspicious of pyeloureteral junction obstruction. All patients underwent DR and evaluation of UJ by transverse CDSG of the bladder within a maximum of 2 weeks. Obstruction was considered in the DR when the hydronephrotic unit showed Differential Renal Function of less than 40%, or when symptomatic intermittent renal colic was present in older children. The number of UJ was counted over a 5 min period and its frequency was calculated for each ureteral orifice. Relative Jet Frequency (RJF) was defined as the UJ frequency of hydronephrotic side divided by total UJ frequency. Receiver-Operating Characteristic (ROC) plots were constructed to determine the best cuttoff for RJF, in order to identify renal units with obstructive hydronephrosis. Results:Twenty-two(45.8%) hydronephrotic units were considered obstructed. The mean RJF differed significantly between obstructive (0.09 ± 0,15) and non-obstructive hydronephrosis (0.41± 0.11)(p<0.001). ROC analysis revealed that RJF< 0.25 was the best threshold and it correctly discriminates obstruction in 91.2% of the childrens with a sensitivity of 86.4% (95%CI=78.6-98.2%) and specificity of 96.15% (95%CI=87,8-99%). The Positive Likelihood Ratio was 22.45 and Diagnostic Odds Ratio was 158.3.The area under the ROC curve was 0.91 (95%CI=0.86-0.98), indicating excellent discrimination power. Conclusions: In this study RJF < 25% was found to be a good indicator of obstruction in children with unilateral hydronephrosis. CDUS evaluation of UJ is an easy and non-invasive method that can be used as an initial diagnostic tool and in follow-up cases, to differentiate obstructed from non-obstructed hydronephrosis in the pediatric population
|
10 |
Correlação entre a ressonância magnética e a ultra-sonografia com duplex scan colorido no diagnóstico da trombose venosa profunda dos membros inferiores / Correlation between magnetic resonance and duplex color sonography in diagnosis of deep venous thrombosis in lower limbsFlávio Mendes de Andrade Neto 07 May 2007 (has links)
A trombose venosa profunda é uma doença que acomete o sistema venoso profundo, com formação de trombos dentro de uma veia e conseqüente reação inflamatória do vaso. O trombo pode determinar a obstrução parcial ou total do vaso. Ocorre em maior número nos membros inferiores e pelve. O quadro normalmente é agudo, mas pode se tornar crônico, com recidivas. Na maior parte dos casos, acomete os membros de forma unilateral. No presente estudo, foram utilizados dois métodos de diagnóstico por imagem na detecção de trombose venosa profunda, que foram a ultra-sonografia em escala de cinza (modo B) associada ao Duplex Scan colorido, e a ressonância magnética. Neste último, foi utilizado meio de contraste paramagnético (Gadolínio) através de administração venosa pediosa. Foram estudados um total de 26 pacientes, 47 membros inferiores e 141 segmentos corporais. A comparação entre os métodos de imagem foi feita por segmento venoso e por segmento corporal. O objetivo do estudo foi avaliar a concordância diagnóstica entre os métodos e a confiabilidade interobservadores nos exames de ressonância magnética, bem como avaliar a sensibilidade, especificidade e acurácia do Duplex Scan colorido em relação à ressonância magnética por segmentos venosos e corporais. Como conclusões do estudo, notamos que houve boa correlação entre a ultrasonografia e a ressonância magnética nos segmentos femorais comuns e superficiais, perfurantes da coxa, poplíteas, tibiais posteriores, fibulares e ilíacas externas. Também houve boa correlação entre os métodos na avaliação das coxas e pernas, e ausência de correlação significativa na pelve. Houve boa confiabilidade interobservadores nos exames de ressonância magnética por segmento venoso. A sensibilidade da ultrasonografia em relação à ressonância magnética foi excelente na pelve, coxas e pernas, sendo a especificidade e acurácia altas na coxa e perna, e baixas na pelve / Deep venous thrombosis is a disease that occurs in deep venous system, with thrombi formation into a vein, and consequent vascular inflammatory reaction. This thrombus can determine partial or total vascular occlusion. It occurs mostly in the lower limbs and pelvis. Clinical presentation is usually acute, but may also be chronic with relapses. In most cases, limb disease is unilateral. In the present study, two different imaging techniques were used in the diagnosis of deep venous thrombosis: B-mode sonography with duplex color Doppler and magnetic resonance imaging with pedal vein administration of paramagnetic contrast media. Twenty-six patients, 47 lower extremities and 141 body segments were evaluated. Comparasion between techniques was made by vascular segments and body segments.The objectives of the study were to evaluate agreement in diagnosis between methods by vascular and body segments, interobserver reliability to read magnetic resonance exams, and sensibility, specificity and accuracy of duplex color sonography in relation to magnetic resonance imaging by vascular and body segments. In conclusion, there was a good correlation between ultrasound and magnetic resonance imaging at common and superficial femoral vein segments, thigh perfurants, calf veins, posterior tibial, fibular and external iliac veins. There was a good correlation between techniques in the evaluation of thighs and legs, but not in the pelvis. There was a good interobserver reliability in the evaluation of vascular segments by magnetic resonance imaging. The sensibility of duplex color sonography in relation to magnetic resonance imaging was excellent in pelvis, thighs and legs; specificity and accuracy were high in thighs and legs, and low in the pelvis
|